Cisco 4506 Switch Hanging

I have got a 4506 switch with Sup V 10GE. This switch is in VTP domain, but in VTP transparent mode. I has got hanged twice, could anybody tell me the reason what could have happend.
There was no configuration change been done to that switch.

Hi Suresh,
CSCsb61172 can be confirmed by looking at the output of "show platform hardware interface all".
eg:
CAT4510#show platform hardware interface all
Global Hardware Gigaport State
RxIpg : 6
TxIpg : 264
FreeListCount : 329 <<<-----
Note that typical values of the free list count are between 20,000 and 64,000 depending on the traffic
being switched. A count of 329 above is too low and indicates a memory leak.
So if you see the number decreasing constantly, then you are running into this issue. The fix is in 12.2(25)EWA5, 12.2(31)SG, and higher.
HTH,
Bobby
*Please rate helpful posts.

Similar Messages

  • Cisco 4506 switch in Err-disable mode

        I have a Cisco 4506 switch and its 10 gig interface is in error disable mode.I tried Shut and no shut the port couple of times but it transits from up to down number of times and then to error-disable. Did anyone else encountered this issue before. kindly advise the solution for the same. thanks         

    Hi Shariq,
    Can you post the output of the show interface status err-disable ? That output contains the reason for putting your port into err-disabled state.
    Best regards,
    Peter

  • WCCP ACL on 4506 switch

    Hi ,
    We have a cisco 4506 switch with the IOS version of 12.2-50.SG1. I would like to know whether any latest IOS version will support redirect ACL with the deny statement for WCCP on a client interface.
    Switch details:
    cisco WS-C4506-E (MPC8245) processor (revision 7) with 524288K bytes of memory.
    Processor board ID FOX1407G5P7
    MPC8245 CPU at 333Mhz, Supervisor IV
    Last reset from Reload
    5 Virtual Ethernet interfaces
    192 FastEthernet interfaces
    26 Gigabit Ethernet interfaces
    403K bytes of non-volatile configuration memory.
    Regards,
    Bala

    Hey CJ,
    Option 1: another option you might consider is intercepting closer to the WAN edge, if that's an available option for you.
    Again, like Patrick mentioned it depends on your network / IP design but if you intercept closer to the WAN edge you should be able to avoid engineering a redirect ACL altogether.
    Option 2: depending on the 3750 platform and code upgrade options, some of the latest 3750 IOS versions include support for deny entries for WCCP redirect ACLs. Check out these release notes (look at the very last bullet point in this list):
    http://www.cisco.com/en/US/docs/switches/lan/catalyst3750x_3560x/software/release/12.2_58_se/release/notes/OL24338.html#wp1009434
    Hope this helps!
    -Chet

  • Juniper SSG 20 optical interface connection to Cisco 4506

    Let me post the same issue to the Optical forum too:
    Hello,
    Here's the problem.
    There's one Juniper SSG 20 firewall with JX-SFP-1GE-SX multimode fiber interface (850nm) (which I can control) and I have to connect it to Cisco 4506 switch which has WS-X4306-GB module and WS-G5484 GBIC interface (also multimode fiber).
    SSG 20 shows link up. Cisco shows link down.
    Unfortunatelly I don't have Cisco 4506 to play with, but I have to find solution for this system. Cisco 4506 show version is:
    #show version
    Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version 12.2(25)EWA9, RELEASE SOFTWARE (fc3) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2007 by Cisco Systems, Inc.
    Compiled Wed 21-Mar-07 12:20 by tinhuang Image text-base: 0x10000000, data-base: 0x115C6158
    ROM: 12.2(31r)SGA1
    Dagobah Revision 226, Swamp Revision 34
    XXXXXXX uptime is 3 weeks, 1 day, 3 hours, 20 minutes System returned to ROM by reload System restarted at 13:19:45 CEST Mon May 19 2008 System image file is "bootflash:cat4000-i9k91s-mz.122-25.EWA9.bin"
    I was able to replicate issue with Cisco 3524 swtich (SSG20 shows link up, Cisco link down, physical down), and solution that I found was to enter interface level command: (config-if)#no negotiation auto. After this command, everything was showing state as "UP" and working as expected (there was traffic going through the optic)
    When I suggested this command as a solution, administrator from the other side was claiming that this command returns "invalid input detected at ^ marker".
    Can anyone tell me is there any known issue between those two products, and maybe alternative to this command, so I can turn off this IEEE 802.3z negotiation if that's the problem.
    Thanks for assistance
    Cheers
    M.

    So I found my solution, but I want to know why is like this.
    The solution was to enter on Cisco the following command:
    (config-if)#speed nonegotiate
    From this link: http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.1E/native/configuration/guide/sw_int.html
    I can see on section: Configuring Link Negotiation on Gigabit Ethernet Ports that this command is doing negotiation exchange of flow-control parameters, remote fault information, and duplex information. Link negotiation is enabled by default.
    And the funniest thing of all is, this speed nonegotiate command doesn't deal with the speed at all :)
    Can someone confirm me what are remote fault information and flow control parameters

  • Cisco 4506 network switch

    i need details of cisco 4506 network switch with supervisor module

    Hi,
    You can visit
    http://cisco.com/en/US/products/hw/switches/ps4324/prod_brochure_list.html
    a Good link on 4500 supervisor engines.
    Regards
    Dinesh
    http://Knowurtech.com
    (Good technical articles. Submit your articles and get featured on our website. Send email to [email protected] To know the benefits http://www.knowurtech.com/be_an_expert.html)
    Hi,
    You can visit
    http://cisco.com/en/US/products/hw/switches/ps4324/prod_brochure_list.html
    a Good link on 4500 supervisor engines.
    Regards
    Dinesh
    http://Knowurtech.com
    (Good technical articles. Submit your articles and get featured on our website. Send email to [email protected] To know the benefits http://www.knowurtech.com/be_an_expert.html)

  • Cisco 4506 getting restarted

    I have Cisco 4506 with Sup V. It is has been joined with one of the VTP domain, but the switch is in Client mode. There are around 10 switches which are connecteing to that switch with trunk ports.
    The switches which are connecting, some are in Transparent Mode and some in Client mode.
    This switch is a root switch. The problem what I am facing with this switch is it has got hanged twice and restarted once. There is no config changes which are been made since it has been installed.
    Can anybody please help me out.

    have you physically changed the switch from one place to another, because even an voltage problem could also lead in such situationz, apart from this, you also try upgrading the OS in the switch. becuase changing the VTP domain it is not at all possible in making a switch getting restarted or hang.
    rate this post if this information is helpful.

  • IOS Upgrade Cisco 4506

    Hi all
    I have a Cisco 4506 with supervisor module II WS-X4013+, this one have the version IOS cat4000-i9s-mz.122-18.EW3.bin, but i want enable SSH So i need upgrade the IOS version, Can anyone help me with a suggestion of IOS for this equipment?
    Thank you.

    Below the info of each module, also this switch has been configured with OSPF
    sh bootflash:
    -#- ED ----type---- --crc--- -seek-- nlen -length- ---------date/time--------- name
    1   .. image        A5C615FB  A18334   29 10322612 May 17 2005 17:41:40 +00:00 cat4000-i9s-mz.122-18.EW3.bin
    sh module
    Chassis Type : WS-C4506
    Power consumed by backplane : 0 Watts
    Mod Ports Card Type                              Model              Serial No.
    ---+-----+--------------------------------------+------------------+-----------
     1     2  Supervisor II+ 1000BaseX (GBIC)     WS-X4013+                   JAE0921D09Q
     2    24  10/100/1000BaseT (RJ45)                WS-X4424-GB-RJ45   JAB06430AB1
     3    48  10/100/1000BaseT (RJ45)                WS-X4548-GB-RJ45   JAE0920CV75
     4     6  1000BaseX (GBIC)                              WS-X4306-GB             JAE074706LH
     5    24  10/100/1000BaseT (RJ45)                WS-X4424-GB-RJ45   JAB060705PM
     6    24  10/100/1000BaseT (RJ45)                WS-X4424-GB-RJ45   JAB0629052P
    thank you.

  • Can i lower cisco 4506 power consumption.

    I just bought old cisco 4506 with SUP4 + 2x48GB  3x48FE poe and have a plan to use it in my small office. (>20 port GB used)
    I heard this chassis is power sucker so i need to lower it power consumption. can you tell me what i can do? such as
    shutdown module that i doesn't used.
    shutown some switchport.
    power off 2nd power supply.
    or your guys has alternative way ex. Cisco EnergyWise?
    Thanks

    I'm using EnergyWise.  I don't see any relevance as to WHY you would want to use it.  I also don't see any information about your PoE requirement, hence, no comment on how you'd like to save money by powering down PoE.  
    The power requirement for the 4506 would, most likely, be LESS than getting six PoE switches individually. 
    I mean, if you don't use PoE, the line cards will only draw what is required.  So trying to save money from energy consumption of the chassis won't make a lot of sense.

  • Cisco 4506 Sup Engine IV

    I have a cisco 4506 with supervisor Engine IV.Initially when i put the switch on the supervisor engine light turns orange.after some diagnosis i found out that one of the fans on the power supply wasnt functioning properly.when i remove this power supply and power the switch the sup engine turns green.However the ethernet interfaces and gigabit ethernet interfaces on the line card r down no traffic is being processed on the switch.what could be the problem.Is there a way u should configure the 4506 to process packets

    Hi Kwak,
    Oki now let us resolve it!!!
    Yes by default all the ports are into vlan 1 so it depends if you want to assign the ports into any other vlan you have to create vlan first. But ports will remain in down down state till the the time you connect any network device to it. Can you please confirm if you have connected any device like workstation or any other device to any port.
    All the ports remain in down down state if they are not active.
    Try to connect some device it should work
    Regards,
    Ankur

  • Configuring new 4506 switches.

    MERRY X-MAS !!!
    I am going to configure IOS version of brand new 4506 Switch with Supervisory engine IV. You guys know that it has separate modules of Supervisory engine, 3 to 4 blades, redundant power supply. Because of this little bit confused. Apart from doing VLAN, STP configs, should I need to do any other configs for the chassis, redundant power supplies, blades, memory ect…..
    If u do have any sample configs plz do help me guys…

    No configuration needed for chassis/RPS. Configuration guidelines should help
    http://www.cisco.com/univercd/cc/td/doc/product/lan/cat4000/12_2_25a/index.htm

  • Packet loss when pinging from/to a cisco 3560e switch

    I see Packet loss when pinging from/to a cisco 3560e switch. CPU utilization is normal.
    Switches are running with IOS c3560e-universalk9-mz.122-35.SE5.bin.
    Packet loss is observed for all the devices irrespective of directly connected or remote devices.
    If i do self pinging, there are no packet loss.
    I don't see any error on interface.
    Can anyone please help me in resolving this issue.

    TCB       Local Address           Foreign Address        (state)
    03737C48  10.47.0.229.60053       10.41.81.55.49         CLOSEWAIT
    039ACDC4  10.47.0.229.61929       10.41.35.250.49        CLOSEWAIT
    03B316C0  10.47.0.229.27544       10.41.81.55.49         CLOSEWAIT
    038228F0  10.47.0.229.16506       10.41.35.250.49        CLOSEWAIT
    039C3D04  10.47.0.229.15207       10.41.81.55.49         CLOSEWAIT
    039A9BD0  10.47.0.229.52983       10.41.81.55.49         CLOSEWAIT
    0394152C  10.47.0.229.22425       161.61.35.250.49       CLOSEWAIT
    037D811C  10.47.0.229.21117       10.41.81.55.49         CLOSEWAIT
    039C12BC  10.47.0.229.37437       10.41.81.55.49         CLOSEWAIT
    03933B84  10.47.0.229.34085       161.61.35.250.49       TIMEWAIT
    03B32340  10.47.0.229.45729       10.41.81.55.49         CLOSEWAIT
    038247D0  10.47.0.229.32816       10.41.81.55.49         CLOSEWAIT
    039A92D8  10.47.0.229.38680       161.61.35.250.49       CLOSEWAIT
    037370F0  10.47.0.229.13212       10.41.81.55.49         CLOSEWAIT
    037D85F0  10.47.0.229.38728       10.41.81.55.49         CLOSEWAIT
    03B2B284  10.47.0.229.23428       10.41.81.55.49         CLOSEWAIT
    03B2ADB0  10.47.0.229.56836       10.41.81.55.49         CLOSEWAIT
    0394BFF0  10.47.0.229.23257       161.61.35.250.49       CLOSEWAIT
    036604DC  10.47.0.229.44437       10.41.81.55.49         CLOSEWAIT
    0394C700  10.47.0.229.22          192.37.184.211.61639   ESTAB
    039B9A68  10.47.0.229.20543       10.41.81.55.49         CLOSEWAIT
    03739B28  10.47.0.229.15392       10.41.81.55.49         CLOSEWAIT
    TCB       Local Address           Foreign Address        (state)
    0392EA48  10.47.0.229.13862       10.41.81.55.49         CLOSEWAIT
    0365E23C  10.47.0.229.27856       10.41.81.55.49         CLOSEWAIT
    03817C0C  10.47.0.229.64929       10.41.81.55.49         CLOSEWAIT
    039357C8  10.47.0.229.22088       10.41.81.55.49         CLOSEWAIT
    037375C4  10.47.0.229.21832       10.41.81.55.49         CLOSEWAIT
    039C20E8  10.47.0.229.18169       10.41.81.55.49         CLOSEWAIT
    03716D08  10.47.0.229.61993       10.41.81.55.49         CLOSEWAIT
    039A74E4  10.47.0.229.62948       10.41.81.55.49         CLOSEWAIT
    03655480  10.47.0.229.14052       10.41.81.55.49         CLOSEWAIT
    039407F0  10.47.0.229.49643       161.61.35.250.49       CLOSEWAIT
    039A53AC  10.47.0.229.13233       10.41.81.55.49         CLOSEWAIT
    03739FFC  10.47.0.229.16605       10.41.81.55.49         CLOSEWAIT
    039B82B8  10.47.0.229.16458       10.41.35.250.49        CLOSEWAIT
    039BEBA4  10.47.0.229.64377       10.41.81.55.49         CLOSEWAIT
    03741980  10.47.0.229.13866       10.41.81.55.49         CLOSEWAIT
    03B3ABF8  10.47.0.229.19365       10.41.81.55.49         CLOSEWAIT
    039B5810  10.47.0.229.24768       10.41.81.55.49         CLOSEWAIT
    03956E48  10.47.0.229.55980       161.61.35.250.49       CLOSEWAIT
    03946820  10.47.0.229.65053       161.61.35.250.49       CLOSEWAIT
    037DBE94  10.47.0.229.15283       10.41.81.55.49         CLOSEWAIT
    039A4854  10.47.0.229.48562       10.41.81.55.49         CLOSEWAIT
    TCB       Local Address           Foreign Address        (state)
    03B33320  10.47.0.229.29803       10.41.81.55.49         CLOSEWAIT
    03B3B79C  10.47.0.229.12142       10.41.81.55.49         CLOSEWAIT
    03713C9C  10.47.0.229.63799       10.41.81.55.49         CLOSEWAIT
    039BBECC  10.47.0.229.14763       10.41.81.55.49         CLOSEWAIT
    03656E40  10.47.0.229.16357       10.41.81.55.49         CLOSEWAIT
    0362A73C  10.47.0.229.62450       10.41.81.55.49         CLOSEWAIT
    039B878C  10.47.0.229.64402       161.61.35.250.49       CLOSEWAIT
    03826CFC  10.47.0.229.16108       10.41.81.55.49         CLOSEWAIT
    03B2CA34  10.47.0.229.17634       10.41.81.55.49         CLOSEWAIT
    03AD78D0  10.47.0.229.15249       161.61.35.250.49       CLOSEWAIT
    03AD967C  10.47.0.229.20389       161.61.35.250.49       CLOSEWAIT
    03B2C560  10.47.0.229.37079       10.41.81.55.49         CLOSEWAIT
    039C5128  10.47.0.229.24711       10.41.81.55.49         CLOSEWAIT
    03822F74  10.47.0.229.54866       10.41.81.55.49         CLOSEWAIT
    0372C5FC  10.47.0.229.13298       10.41.81.55.49         CLOSEWAIT
    0372D278  10.47.0.229.12407       10.41.81.55.49         CLOSEWAIT
    039A33D0  10.47.0.229.36573       10.41.81.55.49         CLOSEWAIT
    039BCEF8  10.47.0.229.53853       10.41.81.55.49         CLOSEWAIT
    039C02D8  10.47.0.229.53725       10.41.81.55.49         CLOSEWAIT
    039B5CE4  10.47.0.229.58027       10.41.81.55.49         CLOSEWAIT
    0381866C  10.47.0.229.17100       10.41.81.55.49         CLOSEWAIT
    TCB       Local Address           Foreign Address        (state)
    039BB374  10.47.0.229.53148       10.41.81.55.49         CLOSEWAIT
    03AD3634  10.47.0.229.19716       161.61.35.250.49       CLOSEWAIT
    0362DAA4  10.47.0.229.19479       10.41.81.55.49         CLOSEWAIT
    0365AE60  10.47.0.229.62209       10.41.81.55.49         CLOSEWAIT
    0362D5D0  10.47.0.229.41327       10.41.81.55.49         CLOSEWAIT
    037D7C48  10.47.0.229.58283       10.41.81.55.49         CLOSEWAIT
    03955474  10.47.0.229.33810       161.61.35.250.49       CLOSEWAIT
    0373B15C  10.47.0.229.23331       10.41.81.55.49         CLOSEWAIT
    036628D0  10.47.0.229.46856       10.41.81.55.49         CLOSEWAIT
    03819584  10.47.0.229.19861       10.41.81.55.49         CLOSEWAIT
    0394D000  10.47.0.229.64732       10.41.35.250.49        CLOSEWAIT
    0394B760  10.47.0.229.19967       161.61.35.250.49       CLOSEWAIT
    039B6BD4  10.47.0.229.40096       10.41.81.55.49         CLOSEWAIT
    03AD7150  10.47.0.229.65184       10.41.35.250.49        CLOSEWAIT
    039BC3A0  10.47.0.229.64702       10.41.81.55.49         CLOSEWAIT
    03B3A724  10.47.0.229.60399       10.41.81.55.49         CLOSEWAIT
    037145E0  10.47.0.229.43951       10.41.81.55.49         CLOSEWAIT
    03955EDC  10.47.0.229.29015       161.61.35.250.49       TIMEWAIT
    0365FB34  10.47.0.229.13961       10.41.81.55.49         CLOSEWAIT
    03828D54  10.47.0.229.12743       10.41.81.55.49         CLOSEWAIT
    037DB40C  10.47.0.229.23708       10.41.81.55.49         CLOSEWAIT
    TCB       Local Address           Foreign Address        (state)
    039AF814  10.47.0.229.15100       10.41.81.55.49         CLOSEWAIT
    0392E344  10.47.0.229.23399       10.41.35.250.49        CLOSEWAIT
    0393DC3C  10.47.0.229.15393       161.61.35.250.49       CLOSEWAIT
    03AD85D0  10.47.0.229.40932       161.61.35.250.49       TIMEWAIT
    039574CC  10.47.0.229.25935       10.41.35.250.49        CLOSEWAIT
    03738B74  10.47.0.229.58656       10.41.81.55.49         CLOSEWAIT
    039AD91C  10.47.0.229.56760       10.41.81.55.49         CLOSEWAIT
    03B3BC70  10.47.0.229.15058       10.41.81.55.49         CLOSEWAIT
    03B2DC54  10.47.0.229.51131       161.61.35.250.49       CLOSEWAIT
    03B393F0  10.47.0.229.11957       10.41.35.250.49        CLOSEWAIT
    039B2610  10.47.0.229.33728       10.41.81.55.49         CLOSEWAIT
    03B311EC  10.47.0.229.18047       10.41.81.55.49         CLOSEWAIT
    039A8E04  10.47.0.229.52022       161.61.35.250.49       CLOSEWAIT
    0365D460  10.47.0.229.12241       10.41.81.55.49         CLOSEWAIT
    03B33E78  10.47.0.229.47640       10.41.81.55.49         CLOSEWAIT
    0372C128  10.47.0.229.60323       10.41.81.55.49         CLOSEWAIT
    03661CD8  10.47.0.229.39923       10.41.81.55.49         CLOSEWAIT
    0393C73C  10.47.0.229.41864       10.41.35.250.49        CLOSEWAIT
    03829584  10.47.0.229.56673       161.61.35.55.49        CLOSEWAIT
    0362AC10  10.47.0.229.31952       10.41.81.55.49         CLOSEWAIT
    039BF078  10.47.0.229.22636       10.41.81.55.49         CLOSEWAIT
    TCB       Local Address           Foreign Address        (state)
    0365CF8C  10.47.0.229.14476       10.41.81.55.49         CLOSEWAIT
    039B443C  10.47.0.229.59226       10.41.81.55.49         CLOSEWAIT
    0393E794  10.47.0.229.56282       10.41.35.250.49        CLOSEWAIT
    03657740  10.47.0.229.25769       10.41.81.55.49         CLOSEWAIT
    03B2F6E8  10.47.0.229.19328       10.41.81.55.49         CLOSEWAIT
    0373AC88  10.47.0.229.25766       10.41.81.55.49         CLOSEWAIT
    039B213C  10.47.0.229.28882       10.41.81.55.49         CLOSEWAIT
    039C07AC  10.47.0.229.38201       10.41.81.55.49         CLOSEWAIT
    03AD8DD0  10.47.0.229.23002       10.41.35.250.49        CLOSEWAIT
    03739048  10.47.0.229.29572       10.41.35.250.49        CLOSEWAIT
    039BA464  10.47.0.229.32273       10.41.81.55.49         CLOSEWAIT
    03B31E6C  10.47.0.229.32521       10.41.81.55.49         CLOSEWAIT
    0365EBE0  10.47.0.229.41319       10.41.81.55.49         CLOSEWAIT
    03938804  10.47.0.229.62841       10.41.35.250.49        CLOSEWAIT
    039A1AF8  10.47.0.229.12758       10.41.81.55.49         CLOSEWAIT
    039B7DE4  10.47.0.229.20921       10.41.81.55.49         CLOSEWAIT
    036549F8  10.47.0.229.51903       10.41.81.55.49         CLOSEWAIT
    03714CC8  10.47.0.229.45145       10.41.81.55.49         CLOSEWAIT
    037425F8  10.47.0.229.56492       10.41.81.55.49         CLOSEWAIT
    03B39D74  10.47.0.229.18174       10.41.81.55.49         CLOSEWAIT

  • FC-2GB module part number for cisco 4503 switch

    Dear Sir,
    We hv a SAN switch MDS-9216 with FC-2GB ports.
    We want to connect the SAN switch to our newly installed cisco 4503 switch which modules is required in the cisco 4503 switch to connect the SAN switch FC-2GB ports.
    Regards
    Deepak

    Deepak,
    Can you explain why you want to do this?
    The Catalyst 4503 is an ethernet switch and does not support FC-2G interfaces. If you want to enable IP access to your storage, you would need an IP storage services module in your MDS 9216. This would then provide GE interfaces which you could connect to your Catalyst 4503. You could then provide IP-based hosts access to FC-connected storage using iSCSI for instance.
    Regards
    Rob.

  • Embeded Event Manager on cisco 3560 switch

    Can someone help me please? I have EEM configured on cisco 3560 switch. The configuration is below. I want that switch inform me through email when device with particilular IP address become unavailable. For some reason this configuration is not good and I can't tell why. I already try to debug this with debug event manager action mail but didn't see any output .
    ip sla 11
    icmp-echo ip address
    frequency 20
    ip sla schedule 11 life forever start-time now
    event manager applet device-TEST
    event snmp oid 1.3.6.1.4.1.9.9.42.1.2.9.1.6.11 get-type exact entry-op lt entry-val "2" poll-interval 20
    trigger occurs 5 period 120
    action 02.0 mail server "ip address" to "[email protected]" from "[email protected]" subject "device is down"

    The mail part looks good, I'm not sure you are hitting the trigger right.
    Why not do a track on the ip sla instead of the snmp stuff?
    Here's a good example of that.
    https://learningnetwork.cisco.com/blogs/network-sheriff/2009/06/19/writing-your-first-eem-applet

  • Converting Eth port to FC port in a cisco 6001 switch

    Hi,
    Back to forum after a long time. I have one issue to discuss regarding cisco 6001 switch. We purchased a new 6001 switch. Want to convert some of the Ethernet ports out of total 48 to FC to join the switch into a existing fabric.
    cisco Nexus 6001 Chassis ("Norcal 64 Supervisor")  - This is what H/W version look like from show version command.
    In the past, we have quite a few Cisco 5548UP switch and the way convert the Ethernet port into FC port is, by going to correct slot/module and then
    (config)# slot 1
    (config-slot)# port 41-48 type fc
    Then "reload" willl complete the conversion. But in the new 6001 switch, it throws the following error when above command is typed. We have full license for the switch including  FC_FEATURES_PKG
    "ERROR: Module type doesn't support this CLI"
    We are running firmware : 6.0(2)N2(2)
    Any help in this regard will be helpful.
    Thanks.

    I have this exact same error;
     show ver
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
    Copyright (c) 2002-2014, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained herein are owned by
    other third parties and are used and distributed under license.
    Some parts of this software are covered under the GNU Public
    License. A copy of the license is available at
    http://www.gnu.org/licenses/gpl.html.
    Software
      BIOS:      version 1.5.0
      loader:    version N/A
      kickstart: version 7.0(5)N1(1)
      system:    version 7.0(5)N1(1)
      Power Sequencer Firmware:
                 Module 1: version v4.0
                 Module 2: version v4.0
      Fabric Power Sequencer Firmware: Module 1: version v4.0
      Microcontroller Firmware:        version v1.2.0.5
      QSFP Microcontroller Firmware:
                 Module 2: v1.3.0.0
      SFP Microcontroller Firmware:
                 Module 1: v1.1.0.0
      BIOS compile time:       12/29/2012
      kickstart image file is: bootflash:///n6000-uk9-kickstart.7.0.5.N1.1.bin
      kickstart compile time:  10/29/2014 22:00:00 [10/30/2014 11:46:56]
      system image file is:    bootflash:///n6000-uk9.7.0.5.N1.1.bin
      system compile time:     10/29/2014 22:00:00 [10/30/2014 11:47:58]
    Hardware
      cisco Nexus 6001 Chassis ("Nexus 64 Supervisor")
      Intel(R) Xeon(R) CPU  @ 2.00 with 8238120 kB of memory.
      Processor Board ID FOC181506P3
      Device name: xxxxxxxxxxxxxx
      bootflash:    7823360 kB
    Kernel uptime is 3 day(s), 17 hour(s), 25 minute(s), 49 second(s)
    Last reset at 642096 usecs after  Fri Feb 27 15:24:40 2015
      Reason: Disruptive upgrade
      System version: 6.0(2)N2(3)
      Service:
    plugin
      Core Plugin, Ethernet Plugin, Fc Plugin
    xxxxxx# conf t
    Enter configuration commands, one per line.  End with CNTL/Z.
    xxxxxx(config)# slot 1
    xxxxxx# port 47-48 type fc
    ERROR: Module type doesn't support this CLI

  • Trouble with Windows7 and Gigabit link on Cisco 3560X switch

    Hello,
    In my company, we are using Cisco IP Phones 7945G (with 2 gigabit network ports) and Cisco 3560X-48P (1GB ports) switches for our users.
    Our client computers are running on Windows 7 SP1 (64bit - Enterprise edition) and are connected behind the IP Phone. We use a "Boradcom
    Xtreme Gigabit" onboard network card on the computers. All ports (on the switch site and IP Phone side) and on the network card of the computer are configured in "auto negotiation". Duplex and speed are set to "auto".
    We tried now to deploy a new engineering software and we are facing a very strange problem. This means that the engineer software fails to download some files from the server. We are using a flat network, all the servers and computers are on the same network segment with no firewall inbetween.
    The firewall and Anti-virus on the computers are configured to allow all incoming/outing connections.
    To troubleshoot, I tried to change all the network cables but I still get same result --> download fails.
    I connected the client computer directly to the Cisco 3560X switch, without the IP Phone and I get the same result.
    I installed a separate network card from INTEL (Intel PRO1000 PT) but I get the same result.
    As last test, I have connected to same client computer directly to a Cisco 2960-8TC switch (100Mbit; auto negotiate) and here is working fine. The software successfully downloads all the files from the server.
    If I connect the computer behind the Cisco 7945 IP Phone, set the speed and duplex of the PC-Port on the Cisco IP Phone 7945G to "100MBit/full duplex" is also working fine.
    Is there any know issue with Windows7 and Gigabit network connections?
    Do I need to set any Registry key on my Windows 7?
    The firmware version of my Cisco 3560X-48P switch is 12.2(53)SE2; do I need to update it?
    The firmware version of the IP Phone 7945G is 9.2.1.
    Thanks in advanced for your help.
    Marc Hoffmann

    Hello, Thanks for your answers. First of all, I have updated the firmware of my Cisco Catalyst 3560X-48P switch to the version 12.2(55)SE5. Unfortunately, this did not solve my problem. As second step, I ran an TDR test on my 3560X switch but I do not get any result. The "Pair status" always says "not completed". Even if I wait for 5 minutes, the status remains at "Not completed". Am I doing something wrong ? To do the TDR test, I use the commande "test cable-diagnostics tdr interface gigabitEthernet 0/XY". For your information, the port gigabitEthernet 0/XY is in a "Connected" status when I run the "show int status" command. Jeff, I think there is no issue on the server side, because if I connect my workstation on a 100MB switch (example Cisco Catalyst 2960-8TC-L) the application works absolutely fine. Also, if I run the application locally on the server, it works fine. As next step, I will connect the workstation directly on our backbone switch and try the same test. Is there perhaps any Registry key in our Windows7 which could cause this trouble? If you have any other ideas or options, please let me know. Thanks a lot, Marc Hoffmann

Maybe you are looking for