CISCO 6500 VS HUAWEI S9700
I NEED COMPARISON BETWEEN CISCO VS-C6509E-SUP2T vs S9700 , becuse i have a very compettive offer from huawei , really i need to onvince my customer that cisco 6500 is better than huawei 9700 in performance
where is the link that shows theat information
Something that "big" and launching in the next few months will not bet published. You'll need to talk to a Cisco R&S SE to get more information.
Similar Messages
-
How to count/determine downtime of Cisco 6500 switch?
Hello,
I work with cisco 6500 switches. now we need to evaluate the down time of all switces. now we using cacti to query system information to switches using SNMP, but some times cacti didnt get the data because of high cpu in switch so the switch stop di SNMP service. because of that, the data in Cacti not valid to determine our switch Downtime.
Is there any tools or ather way to monitor Cisco switch downtime??
Thanks a lot.just like a reminding system. it can be send an email or some message.
EEM can be configured to send someone an email when some kind of "event" is triggered, such as an uplink goes DOWN/UP.
However, the chassis can't send an email if it's down but can be configured to send out an email when the supervisor card boots up. -
Cisco 6500 with sup720 booting to rommon
Please how can I solve this problem. This cisco 6500 boots to rommon mode, I can't see any error showing why its booting to rommon.
Here is the boot process:
System Bootstrap, Version 8.5(4)
Copyright (c) 1994-2009 by cisco Systems, Inc.
Testing lower main memory - data equals address
Testing lower main memory - checkerboard
Testing lower main memory - inverse checkerboard
Clearing lower memory for cache initialization
Clearing bss
Clearing autoboot state machine
melody_present_reg: 1st read w/ 0x5555
melody_present_reg: 2nd read w/ 0xaaaa, reversed: 0x5555
Bootdisk adapter is detected, enabling bootdisk access...
Reprogramming CS1 w/ Melody value...
Reading monitor variables from NVRAM
Reset reason for CPU board 0xffff , BaseBoard 0x281ffff, display 0x20000System Reset by Software.
Enabling interrupts
Initializing TLB
Initializing cache
Initializing required TLB entries
MOBILE dimm - rev 0.15
Initializing main memory
Sizing NVRAM
Initializing PCMCIA controller
Initializing USB2.0 controller
Exiting init
Cat6k-Sup720/SP processor with 1048576 Kbytes of main memory
Autoboot: failed, BOOT string is empty
Autoboot executing command: "boot "
Initializing ATA monitor library...
string is bootdisk:s72033-ipbasek9-mz.122-33.SXJ2.bin
Loading image, please wait ...
Initializing ATA monitor library...
Stack pointer : 0x8FFFFF80
monstack : 0x800FFFC0
monra : 0xBFC26EC4
edata : 0x80108580
magic : 0xFEEDFACE
memsize : 0x10000000
uncomp_size : 0x05090C00
comp_size : 0x05090C00
comp_checksum : 0x98ECBE18
uncomp_checksum : 0x98ECBE18
CZIP_MEM_BASE : 0x80000000
_end : 0x8010BA00
Self extracting the image...
IOS compressed src copy is : 0x80108594
czip + IOS tar size is :0x00E01FA8
czip + IOS Tar image is now :0x80108794
cptr is now :0x8010BB00
IOS compressed dest copy is : 0x8010BB00
[OK]
image_entry :0x80100000
image_entry :0x80100000
__start : 0x80100000
tar_avail_size is now :0x0428EA00
Tar image address is : 0x80F0DB00
tar_size is : 0x0428E600
cpu type : 0x00000019
uncomp_size : 0x05090C00
monstack : 0x800FFFC0
image_info.entry_point = 0x80100000
image_info.section_count = 0x00000005
image_info.monstack = 0x800FFFC0
image_info.monra = 0xBFC26EC4
image_info.param0 = 0x00000002
image_info.param1 = 0x00000000
image_info.param2 = 0x800066A8
image_info.param3 = 0x80100000
image_info.reg_k0 = 0x80F0DB00
image_info.reg_k1 = 0x0428E600
Section Index = 0x00000000
source = 0x8010BC1C
dest = 0x80100000
bytes = 0x00010000
Section Index = 0x00000001
source = 0x8011BC1C
dest = 0x80110000
bytes = 0x00000720
Section Index = 0x00000002
source = 0x8011C33C
dest = 0x80110720
bytes = 0x00000020
Section Index = 0x00000003
source = 0x8011C35C
dest = 0x80110740
bytes = 0x00DF1730
Section Index = 0x00000004
source = 0x80F0DA8C
dest = 0x80F01E70
bytes = 0x00000000
reg_v0: 0x00000000
reg_k0: 0x80F0DB00
reg_k1: 0x0428E600
tar_start: 0x00000000
tar_size: 0x00000000
Tar image address is : 0x80F0DB00
tar size is :0x00B6130E
Tar magic : ustar Tar filename : C2LC memsize : 0x10000000
Tar gid : 035231Tar uncomp_size : 0x00B6130E
Tar mtime : 11672344432 Tar username : ccaiTar comp_checksum : 0x0000125F
Tar group name : buildTar prefix : tar_size in czip : 0x0428E600
Stack pointer : 0x8FFFFF80
monstack : 0x800FFFC0
monra : 0xBFC26EC4
edata : 0x80110740
magic : 0xFEEDFACE
memsize : 0x10000000
uncomp_size : 0x02B3E7F0
comp_size : 0x00DF171C
comp_checksum : 0xE917F280
uncomp_checksum : 0xD094D890
Compressed IOS src copy is : 0x80110754
tar_dest is :0x8BD69200
tar_size is :0x0428E600
Compressed IOS dest copy is : 0x8AF77AE4
Tar src before IOS decompression is : 0x80F0DB00
Tar dest before IOS decompression is : 0x8BD69200
compressed IOS src is : 0x8AF77AE4
IOS uncompressed dest copy is : 0x8013C160
Self decompressing the image : ############################################################################################################################################################################################################################## [OK]
e_shoff :
0x02B3E660
e_flags : 0x10001001
e_phnum :
0x00000001
Source elf_hdr->e_shnum = 0x0000000A
Setting up to copy ELF section 0x00000001
to image_info section 0x00000000
sh_name = 0x0000000B
sh_type = 0x00000001
sh_flags = 0x00000007
sh_addr = 0x80100000
sh_offset = 0x00000060
sh_size = 0x02640000
sh_link = 0x00000000
sh_info = 0x00000000
sh_addralign = 0x00000020
sh_entsize = 0x00000000
Setting up to copy ELF section 0x00000002
to image_info section 0x00000001
sh_name = 0x00000011
sh_type = 0x00000001
sh_flags = 0x00000003
sh_addr = 0x82740000
sh_offset = 0x02640060
sh_size = 0x00373440
sh_link = 0x00000000
sh_info = 0x00000000
sh_addralign = 0x00000008
sh_entsize = 0x00000000
Setting up to copy ELF section 0x00000003
to image_info section 0x00000002
sh_name = 0x00000017
sh_type = 0x00000001
sh_flags = 0x00000003
sh_addr = 0x82AB3440
sh_offset = 0x029B34A0
sh_size = 0x0003EEE4
sh_link = 0x00000000
sh_info = 0x00000000
sh_addralign = 0x00000004
sh_entsize = 0x00000000
Setting up to copy ELF section 0x00000004
to image_info section 0x00000003
sh_name = 0x00000024
sh_type = 0x00000001
sh_flags = 0x10000003
sh_addr = 0x82AF2324
sh_offset = 0x029F2384
sh_size = 0x0000423C
sh_link = 0x00000000
sh_info = 0x00000000
sh_addralign = 0x00000010
sh_entsize = 0x00000000
sh_type = 0x00000008
sh_flags = 0x10000003
sh_addr = 0x82AF6560
sh_offset = 0x029F65C0
sh_size = 0x00000940
sh_type = 0x00000008
sh_flags = 0x00000003
sh_addr = 0x82AF6EA0
sh_offset = 0x029F65C0
sh_size = 0x021FE100
tar file start = 0x84D02F50
cpu type : 0x00000019
uncomp_size : 0x02B3E7F0
monstack : 0x800FFFC0
image_info.entry_point = 0x80100000
image_info.section_count = 0x00000005
image_info.monstack = 0x800FFFC0
image_info.monra = 0xBFC26EC4
image_info.param0 = 0x00000002
image_info.param1 = 0x00000000
image_info.param2 = 0x800066A8
image_info.param3 = 0x80100000
image_info.reg_k0 = 0x84D02F50
image_info.reg_k1 = 0x0428E600
Section Index = 0x00000000
source = 0x8013C1C0
dest = 0x80100000
bytes = 0x02640000
Section Index = 0x00000001
source = 0x8277C1C0
dest = 0x8274CFB0
bytes = 0x00373440
Section Index = 0x00000002
source = 0x82AEF600
dest = 0x82AC03F0
bytes = 0x0003EEE4
Section Index = 0x00000003
source = 0x82B2E4E4
dest = 0x82AFF2D4
bytes = 0x0000423C
Section Index = 0x00000004
source = 0x8BD69200
dest = 0x84D02F50
bytes = 0x0428E600
data_size in czip : 0x00001000
bss end of IOS is : 0x84D01F50
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, s72033_sp Software (s72033_sp-IPBASEK9-M), Version 12.2(33)SXJ2, RELEASE SOFTWARE (fc4)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2011 by Cisco Systems, Inc.
Compiled Thu 15-Dec-11 01:29 by prod_rel_team
Image text-base: 0x4010132C, data-base: 0x4274CFB0
Active crashed three times, disabling auto-boot and dropping to rommon
Firmware compiled 15-Nov-11 14:23 by integ Build [100]
*Jan 1 02:27:12.643: %PFREDUN-6-ACTIVE: Initializing as ACTIVE processor for this switch
*Jan 1 02:27:13.459: %PFREDUN-4-SUP_FORCE_TO_ROMMON: Supervisor forced to rommon with reason: Active crashed three times in a row
System Bootstrap, Version 8.5(4)
Copyright (c) 1994-2009 by cisco Systems, Inc.
Cat6k-Sup720/SP processor with 1048576 Kbytes of main memory
rommon 1 > -
Hi,
we want to connect cisco VPC and huawei IRF together, Is there anyone has experience?
thank you!
Jeremyno one answer me, I will discuss this issue with huawei and customer.
you know in china ,they will remove cisco products , we have a lot of problem with this, may be we need a lab to test it -
Cisco 6500 --ACL entries showing incorrect order.
Hi guys,
I need your suggestion on my following issue:
I have configure the ACL entries on my cisco 6500 series box but I see the ACL entries showing incorrect order when I check for the same.
Eg:
Europebox#show access-list 50
10 permit 192.50.20.2 (10 matches)
15 permit 192.52.0.134 (98 matches)
75 permit 198.29.232.23 (38 matches)
80 permit 10.96.127.14
90 permit 192.22.2.10
40 permit 192.22.0.76
anyhelp would be appriciated
regards
nehaHi neha,
This is the expected behaviour that you see for the standard access-lists.
Regards
Inayath -
Cisco 6500 shows less traffic for NetFlow export
I am using a Thrid party NetFlow tool, Enabled NetFlow on the Cisco 6500 as per recommendations and getting only half amout of traffic passing thorugh the interfaces. I have verified with 3 different NetFlow based tools, everything showing the same value. Is there any bug in my Cisco 6500. Any one faced this issue. Attached the output of (show run, show version)
CheersHi Jake,
I have already investigated this, the exporting interval and aging time for flows are set to lower active timeout. Is there any way to see all the flows are beeing captured and exported both on MSFC and PFC.
Cheers -
Cisco 6500 Sup2 IOS with SLB support
Hello
A have two questions about SLB funcionality on Cisco 6500 SUP2/MSFC2
1) Is IP LAN ONLY ios support SLB ? If yes, does it have any restrictions ?
2) How heavy IOS SLB for processor ? (i mean in dispatched mode).Are sup-bootflash: and sup-bootdisk: the same thing ?
No, they are not. sup-bootflash: is located inside but the sup-bootdisk: is located OUTSIDE and is physically accessible. If you look at the line card, you'll see a CF slot marked "Disk0:" or "Slot0". This is the sup-bootdisk:. It is also known as "disk0:". Confusing, I know.
Can I make use of the disk0 of both chassis to perform ios upgrade ?
Of course you can. I perform VSS upgrade just using one of the disk0: and push the IOS from the disk0: to the two supervisor cards.
By setting the boot path to disk0
You can too. The sup-bootflash: and the sup-bootdisk:/disk0: are the same physical format.
A word of caution: I cannot stop reiterating the importance of checking the MD5 hash value of the IOS file in the sup-bootdisk: or sup-bootflash: BEFORE rebooting the chassis for an IOS upgrade. Make sure the MD5 hash value match exactly to the MD5 hash value found in the Cisco website. Once they are match, check the boot variable string, the config-registry and you're off to the next step. -
PPPoE Cisco 6500 + 7600-SIP-400
Hello,
we use a lot of Cisco 6500 switches across our network. I bought one 7600-SIP-400 with one SPA-5X1GE-V2 module.
Unfortunatelly I have found that there is no command support for PPPoE in my IOS version 12.2 SXI13.
Can somebody tell me which IOS version do I have to use to get command support for PPPoE Server?
Thank you.
Milan"Doesn't have to be a Cisco box. "
If you're still interested in solving this (or haven't already), you can mail me at [email protected]
Cheers,
Anton -
Hi,
does anyone has experience with ip tcp intercept configuration on cisco 6500 for protecting network against TCP SYN flooding.
Which mode is recommended to configure (intercept or watch) and how can affect CPU on cisco 6500?
Any infos regarding that would be much appreciated.
Thank you
SaljaHey Salja,
In Sup720 for TCP Intercept the support is as follows:
Watch mode: Initial TCP packets (SYN, SYN-ACK and ACK of SYN-ACK) and terminating TCP packets (FIN, RST) of a TCP flow is sent to RP for processing in SW. All other TCP packets of the flow are handled in HW using netflow (if TCP packets come in before the netflow entry is created it will get punted to SW). Note that the rate of netflow entry creation is limited and if new TCP connections come in at a rate faster than the rate at which netflow entries can be created in HW there will be large number of packets hitting the CPU.
Intercept Mode: For Intercept mode without timeout the behavior is similar to Watch mode mentioned above. Intercept mode with timeout all packets of a TCP flow is handled in SW by the RP.
So its not advised to use TCP intercept on 6500 as it may degrade box performance. I would suggest using firewall for this feature.
HTH.
Regards,
RS. -
Cisco 6500 power supply and module (hot-swappable?)
Hi everyone!
We have currently a Cisco 6500 with 2 power supply of 3000w. We want to replace these PS for 2 new ones, which have higher wattage: 6000w.
Can we replace them without needing to turn the 6500 off?. I mean, What happens if we insert a 6000w PS and the switch is working with one 3000w PS?
Is it possible to do this replacement "on hot"?
And second, we also have a ws-x6708-10g-3c module. Can we insert this module "on hot"? Without needing to turn the Catalyst 6500 off?
Thanks a lot! and looking forward to an answer.Depends on your setup the table should be able to help:
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst6500/ios/12-2SX/configuration/guide/book/pwr_envr.html#wp1020384
Configuration Change
Effect
Redundant to nonredundant
•System log and syslog messages are generated.
•System power is increased to the combined power capability of both power supplies.
•Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
Nonredundant to redundant (both power supplies must be of equal wattage)
•System log and syslog messages are generated.
•System power is decreased to the power capability of one supply.
•If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
Equal wattage power supply is inserted with redundancy enabled
•System log and syslog messages are generated.
•System power equals the power capability of one supply.
•No change in module status because the power capability is unchanged.
Equal wattage power supply is inserted with redundancy disabled
•System log and syslog messages are generated.
•System power is increased to the combined power capability of both power supplies.
•Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
Higher or lower wattage power supply is inserted with redundancy enabled
•System log and syslog messages are generated.
•The system does not allow you to operate a power supply of different wattage even if the wattage is higher than the installed supply. The inserted supply shuts down.
Higher or lower wattage power supply is inserted with redundancy disabled
•System log and syslog messages are generated.
•System power is increased to the combined power capability of both power supplies.
•Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
Power supply is removed with redundancy enabled
•System log and syslog messages are generated.
•No change in module status because the power capability is unchanged.
Power supply is removed with redundancy disabled
•System log and syslog messages are generated.
•System power is decreased to the power capability of one supply.
•If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
System is booted with power supplies of different wattage installed and redundancy enabled
•System log and syslog messages are generated.
•The system does not allow you to have power supplies of different wattage installed in a redundant configuration. The lower wattage supply shuts down.
System is booted with power supplies of equal or different wattage installed and redundancy disabled
•System log and syslog messages are generated.
•System power equals the combined power capability of both power supplies.
•The system powers up as many modules as the combined capacity allows. -
Is DOM supported using SNMP on Cisco 6500;s?
Is DOM supported using SNMP on Cisco 6500's? I've configured DOM on 6509 using transceiver type all -> monitoring. Is DOM enable for SNMP mibs? Here's the MIB I got from a vendor. .1.3.6.1.4.1.3607. And I'm unable to walk it on any of my Cisco devices including Nexus 5672 and 4900.
That oid looks like the sysoid for the ONS series of products. I don't think that will work in this case. Unfortunately, I can't offer any other advice, I've not looked into snmp support for DOM.
chris -
Cisco 6500 with SUP 720 - Invalid boot Image
Diagnostic sanity check on the 6500 reports Invalid boot image "bootdisk:<output omitted>
The boot statement on the 6500 is :-
boot system bootdisk:<filename.bin> and the 6500 boots fine.
Please advise.
Thank You.Hi ,
I have found bug which is internally found by cisco.The bug is CSCsc98471 and following are details of bug .
The command "show diagnostic sanity" checks amongst other things, if the current bootstring is matching pointing to an existing file.
Since ION bootstring format has been extended (assuming an installed image) this check fails although the bootstring is correct.
Can be easily reproduced by entering the "show diagnostic sanity" command.
6500-6#show diagnostic sanity
Pinging default gateway 172.26.197.33
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to 172.26.197.33, timeout is 2 seconds:
Success rate is 100 percent (5/5), round-trip min/avg/max = 1/2/4 ms
Could not verify boot image "sup-bootdisk:/newsys/s72033/base/s72033-adventerprisek9_wan_dbg-vm," specified in the boot string.
6500-6#show bootvar
BOOT variable = sup-bootdisk:/newsys/s72033/base/s72033-adventerprisek9_wan_dbg-vm,12;
6500-6#dir sup-bootflash:/newsys/s72033/base/
Directory of sup-bootdisk:/newsys/s72033/base/
84 -rwx 1375696 Jan 5 2006 20:51:24 -08:00 imf.tar
85 -rwx 12873200 Jan 5 2006 20:51:22 -08:00 s72033-adventerprisek9_wan_dbg-vm
It is found in 12.2(18.09.20)SX3.39.
*** open a TAC case so that the same bug is fixed in 12.2(18)SXF4.
Hope it helps you.Plz rate it.
Thanks,
satish -
is the NSF feature on the 6500 the same as "graceful-restart" ????/
perBy graceful-restart, if you are referring to hitless upgrade, IOS modularity then it is not. Following page should address your questions on IOS modularity.
http://www.cisco.com/en/US/products/hw/switches/ps708/products_qanda_item0900aecd80313e1f.shtml -
Cisco 6500 VSS , VSL Link Connection Issue
Hello Everyone
actually i have two Cisco 6509E with two VS-S720-10G and want to run VSS on them
i do all the config same as cisco recommend, but i get somethings wrong on them, 1st. on switch2 , under "switch virtual domain" when i enter switch2, its not accepot and 2nd. non of 10G link goes up & so VSL link always down
here is my config and show commands
SWITCH#1
==================================
switch virtual domain 10
switch mode virtual
switch 1 priority 110
mac-address use-virtual
redundancy
main-cpu
auto-sync running-config
mode sso
interface Port-channel1
no switchport
no ip address
switch virtual link 1
mls qos trust cos
no mls qos channel-consistency
interface TenGigabitEthernet1/5/4
no switchport
no ip address
mls qos trust cos
no cdp enable
channel-group 1 mode on
interface TenGigabitEthernet1/5/5
no switchport
no ip address
mls qos trust cos
no cdp enable
channel-group 1 mode on
======
SWITCH#2
switch virtual domain 10
switch mode virtual
switch 1 priority 110
redundancy
main-cpu
auto-sync running-config
mode sso
interface Port-channel2
no switchport
no ip address
switch virtual link 2
mls qos trust cos
no mls qos channel-consistency
interface TenGigabitEthernet2/5/4
no switchport
no ip address
mls qos trust cos
no cdp enable
channel-group 2 mode on
interface TenGigabitEthernet2/5/5
no switchport
no ip address
mls qos trust cos
no cdp enable
channel-group 2 mode on
Thank you all in advanceHello Dear Reza
at first, thanks for your replay
below you can find the Show Version of the SWITCH#1
6500-1#sh version
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVENTERPRISEK9-M), Version 15.1(1)SY1, RELEASE SOFTWARE (fc5)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Wed 01-May-13 13:16 by prod_rel_team
ROM: System Bootstrap, Version 12.2(17r)SX5, RELEASE SOFTWARE (fc1)
BOOTLDR: Cisco IOS Software, s72033_rp Software (s72033_rp-ADVENTERPRISEK9-M), Version 15.1(1)SY1, RELEASE SOFTWARE (fc5)
6500-1 uptime is 6 minutes
Uptime for this control processor is 6 minutes
System returned to ROM by power cycle at 11:49:28 UTC Mon Nov 17 2014 (SP by power on)
System image file is "sup-bootdisk:s72033-adventerprisek9-mz.151-1.SY1.bin"
Last reload reason: reload
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
[email protected].
cisco WS-C6509-E (R7000) processor (revision 1.6) with 983008K/65536K bytes of memory.
Processor board ID SMC18080014
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
Last reset from s/w reset
1 Virtual Ethernet interface
99 Gigabit Ethernet interfaces
5 Ten Gigabit Ethernet interfaces
1917K bytes of non-volatile configuration memory.
65536K bytes of Flash internal SIMM (Sector size 512K).
Configuration register is 0x2102
as you see i use "adventerprisek9-mz.151-1.SY1" but now downgrade it to "s72033-adventerprisek9_wan-mz.122-33.SXJ2" , so nothing change and EtherChannel still not up
below are the show commands:
VSS-Sw2#show etherchannel 2 summary
Flags: D - down P - bundled in port-channel
I - stand-alone s - suspended
H - Hot-standby (LACP only)
R - Layer3 S - Layer2
U - in use N - not in use, no aggregation
f - failed to allocate aggregator
M - not in use, no aggregation due to minimum links not met
m - not in use, port not aggregated due to minimum links not met
u - unsuitable for bundling
d - default port
w - waiting to be aggregated
Number of channel-groups in use: 1
Number of aggregators: 1
Group Port-channel Protocol Ports
------+-------------+-----------+-----------------------------------------------
2 Po2(RD) - Te2/5/4(D) Te2/5/5(D)
Last applied Hash Distribution Algorithm: -
===========================
VSS-Sw2#sh etherchannel 2 port
Ports in the group:
Port: Te2/5/4
Port state = Down Not-in-Bndl
Channel group = 2 Mode = On Gcchange = -
Port-channel = null GC = - Pseudo port-channel = Po2
Port index = 0 Load = 0x00 Protocol = -
Age of the port in the current state: 0d:00h:00m:00s
Port: Te2/5/5
Port state = Down Not-in-Bndl
Channel group = 2 Mode = On Gcchange = -
Port-channel = null GC = - Pseudo port-channel = Po2
Port index = 0 Load = 0x00 Protocol = -
Age of the port in the current state: 0d:00h:00m:00s
Last applied Hash Distribution Algorithm: - -
GUI Tool for Cisco 6500 Chassis
Hi
We have a requirement to allow our Service Desk to amend vlans on switchports on a range of 6509 chassis.
Is there a tool, (like SDM for routers) which would allow them to do this using a GUI? We need to keep it as simple as possible as the Service Desk users have no experience of configuringCisco kit.
We have Cisco Prime, however, I can't see anything which shows a graphical representation of the actual switchports on a chassis?
If there isn't a Cisco product which supports this, does anyone know of a third party app which would do the job?
Thanks
JHi datamodule, i see that you are looking for a 24 ports 1/10G SFP module for the Catalyst 6509E. From what i am looking at it's either 1G or 10G. Please check this link for further assistance: http://cs.co/9000YTBE. Feel free to message me for further assistance.
Thanks,
Angela ([email protected])
Maybe you are looking for
-
IF and ABS condition statement in BEX query designer
Hi, I would like to ask the best way for me to produce an acceptable result from Excel IF and ABS Condition statement. The condition statement that I have on my Excel file is =IF((A2-B2)>0,ABS(A2-B2),0) I'm trying multiple times to reproduce this in
-
Mass update of product master (lock material record)
Hi! Does anyone know of any program that I can use to carry out mass update of product master in SRM? I am specifically looking at locking the materials. I originally intended to use LSMW and create a recording for it. However, the recording didn't w
-
Why will a query work in SQL Developer but not in Apex?
Here's a good one. I created a dynamic LOV with the following query. select e.DESCR d, ee.ENTRD_EVNT_SK r from PT_EVNT_IN_DIV eid, PT_ENTRD_EVNT ee, PT_EVNT e where ee.PGNT_SK = :PGNT_SK and ee.CNTSNT_SK = :CNTSNT_SK and ee.EVNT_IN_DIV_SK = eid.EVNT_
-
Hi friends My client wants when ever a workitem gets in the UWL a email has to notify that a workitem has come. I know that there is a report program RSWUWFML2 and configuration of this report with correct varient you can achieve it. I have followed
-
Anyone know when Apple is going to fix the wifi problem inYosemite? I'm using my $10 netbook now as my Macs are screwed......and so am I....AGAIN.