Cisco 831 Power Supply

Hello,
please i cannot find part number of Power Supply for Cisco 831.
We need new one for this router.
Thank you
Tomas

PWR-830-WW1= is the part number for the CISCO830 Series External Spare AC Power Supply.
Below are some useful document URLs:
Cisco 831 Router and SOHO 91 Router Hardware Installation Guide
http://www.cisco.com/en/US/docs/routers/access/800/831/hardware/installation/guide/overview.html
Cisco Cable Product Numbers, Part Numbers, and Descriptions
http://www.cisco.com/en/US/products/hw/routers/ps332/products_tech_note09186a0080094b45.sh
tml
Upgrading Cisco IOS Software for the Cisco 806, 826, 827, 828, 831, 836, and SOHO70
Routers
http://www.cisco.com/en/US/products/hw/routers/ps380/products_tech_note09186a0080094b23.shtml
Marcos Hernandez
Technical Marketing Engineer
Cisco Systems, Inc.

Similar Messages

  • Cisco 12008 Power Supply Fan Tray Hot Swappable? 09/10/14

    Hello,
    I have a power supply fan tray [PART NO. GSR8-PWRBLOWER(=)—Power supply fan tray ] for a EOL Cisco 12008.
    Q: This hot swappable while 12008 is online/powered on?
    Thanks,
    Kent C.

    Typically, when "hot swappable" is mentioned, it means that these items can be replaced while not impacting the operation of the system.
    When an optics module is pulled, traffic will be impacted. Depending upon the system's configuration, the traffic will need to re-converge.
    The optics modules can be installed or removed while the system is powered up.
    Hope this helps.

  • Cisco 6500 power supply and module (hot-swappable?)

    Hi everyone!
    We have currently a Cisco 6500 with 2 power supply of 3000w. We want to replace these PS for 2 new ones, which have higher wattage: 6000w. 
    Can we replace them without needing to turn the 6500 off?. I mean, What happens if we insert a 6000w PS and the switch is working with one 3000w PS?
    Is it possible to do this replacement "on hot"?
    And second, we also have a ws-x6708-10g-3c module. Can we insert this module "on hot"? Without needing to turn the Catalyst 6500 off? 
    Thanks a lot! and looking forward to an answer.

    Depends on your setup the table should be able to help:
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst6500/ios/12-2SX/configuration/guide/book/pwr_envr.html#wp1020384
    Configuration Change
    Effect
    Redundant to nonredundant
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Nonredundant to redundant (both power supplies must be of equal wattage)
    •System log and syslog messages are generated.
    •System power is decreased to the power capability of one supply.
    •If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
    Equal wattage power supply is inserted with redundancy enabled
    •System log and syslog messages are generated.
    •System power equals the power capability of one supply.
    •No change in module status because the power capability is unchanged.
    Equal wattage power supply is inserted with redundancy disabled
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Higher or lower wattage power supply is inserted with redundancy enabled
    •System log and syslog messages are generated.
    •The system does not allow you to operate a power supply of different wattage even if the wattage is higher than the installed supply. The inserted supply shuts down.
    Higher or lower wattage power supply is inserted with redundancy disabled
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Power supply is removed with redundancy enabled
    •System log and syslog messages are generated.
    •No change in module status because the power capability is unchanged.
    Power supply is removed with redundancy disabled
    •System log and syslog messages are generated.
    •System power is decreased to the power capability of one supply.
    •If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
    System is booted with power supplies of different wattage installed and redundancy enabled
    •System log and syslog messages are generated.
    •The system does not allow you to have power supplies of different wattage installed in a redundant configuration. The lower wattage supply shuts down.
    System is booted with power supplies of equal or different wattage installed and redundancy disabled
    •System log and syslog messages are generated.
    •System power equals the combined power capability of both power supplies.
    •The system powers up as many modules as the combined capacity allows.

  • Cisco 6500 Power Supply and related configurations if any?

    Hi,
    My query is with regards to the best practices deployed for connecting Cisco 6509 switches in the DC, attached is the existing and proposed setups, also would appreciate getting the related switch configs to acheive redundancy and high availability of the switches in the DC network.
    Regs,
    Mahesh

    Hi,
    this depends on what power-supplies you have and how loaded your chassis is.
    For Example:
    When your chassis is loaded with
         1x Sup720
         8x GE-TX Linecard (WS-X6748)
         2x 3kW Power-Supplies (WS-CAC-3000W)
    Then you have to run the chassis in Combined-Mode because, even if there is no second Sup, the same power is allocated to the second sup-slot as if there were one installed.
    Having 2x 6kW Power-Supplies, then you should run your chassis in Redundancy-Mode and go with your proposed setup.
    for combined-mode use:
    cat6k(config)# power redundancy-mode combined
    for redundancy-mode use:
    cat6k(config)# power redundancy-mode redundant
    verify with:
    cat6k# show power
    system power redundancy mode = combined
    Hope this helps!
    regards,
        Dirk

  • Odd power supply fault callhome emails on Cisco 2232 FEXs?

    We recently enabled smtp callhome for our ucs pod a few days ago. Since then, we've received more than a dozen email bursts about power supply failures in each of the four Cisco Nexus 2232TP FEXs in our pod. In each case, we get a "Recovered" email within a minute or two, and we're not seeing power supply failure emails for any other devices within the UCS pod.
    Here's a sample email burst from this morning, showing the subject lines within my email inbox:
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 power: error
    If we were seeing this from just one fex, I'd suspect a hardware issue. If any of the other UCS devices (rackmount/blade servers, fabric interconnects, etc) reported similar issues, I'd suspect a power feed problem within the DC.
    But this has me baffled. If it helps, the UCS pod is running firmware 2.0.3c
    Cheers,
    Paul

    Thanks Paul,
    It is known ( cosmetic ) issue with power supply model. 
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCtz84683
    The above is resolved in recent version of Nexus 5K switch software. New defect to port the fix to UCSM has been submitted today
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCuc87547
    It will take a while to get published on web site.
    Even though they are cosmetic, I would suggest you open a TAC SR with UCSM, FEX tech support and above bug IDs so that we can track the resolution.
    HTH
    Padma

  • Cisco 3850 Redundant Power Supply Reporting Issue

    We have deployed several Cisco 3850's. Several are showing the following symptom
    ont2-tc3-es01#sh env power
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1A  PWR-C1-715WAC       DCB1702G0QU  OK              Good     Good     715
    1B  PWR-C1-715WAC       DCB1702G0G6  No Response     Good     Good     715
    Every single switch at this particular location has the same status on the B power supply. The problem was there on the previous code level (3.2.2) and we recently upgraded to 3.3.5 to resolve some SNMP bugs on the switches we also expected the latest Assurewave version to fix this issue also. So couple questions:
    1. Anyone else seeing this?
    2. Anyone found a fix for it?
                   Thanks!
                              Marty

    Hi Zabeel,
                       I did talk with TAC - per the engineer there are two bugs that cause the issue and one was fixed in 3.3.5 - so we upgraded all our 3850's to that code level. Unfortunately for us, that still didn't fix the issue. TAC suggested that it may be fixed in rev 3.7.0, but that has not officially been confirmed by Cisco's developers.
             We're waiting for the official "fix" before going through another round of switch upgrades.
            TAC did suggest reseating the power supply if you still have the issue after the upgrade to 3.3.5 - but that's not really an option for me since my switches are geographically spread out.
       HTH
                 Marty

  • Cisco Power Supply error

    What does out of regulation limits means ?
    1 red "OUTPUT FAIL," normally is off but illuminates when power supply outputs are out of regulation limits
    Thanks
    Rosa

    Hi,
    Seet this:
    LED
    Meaning
    INPUT OK
    AC-input power supplies:
    •Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.)
    •Off—Source AC voltage falls below 70 VAC, is not present, or the PEM is turned off.
    DC-input power supplies:
    •Green—Source DC voltage is OK. (-40.5 VDC or greater.)
    •Off—Source DC voltage falls below -33 VDC or is not present at the PEM.
    FAN OK
    Green—Power supply fan is operating properly.
    Off—Power supply fan failure is detected.
    OUTPUT FAIL
    Red—Problem with one or more of the DC-output voltages of the power supply is detected.
    Off—DC-output voltages within acceptable margins.
    Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal.
    This is for 6500 switches but apply to almost all models.
    http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Chassis_Installation/Cat6500/0apwsply.html#wp1025570
    Hope this helps.

  • Power supply error, Cisco switch 3750

    Hello,
    Can someone help me with a  power supply problem...?
    Switch cisco WS-C3750-24P is showing "Unavail" from sh env all
    Switch3750#sh env all
    FAN is OK
    TEMPERATURE is OK
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1  Built-in                                         Unavail
    2  Built-in                                         Good
    3  Built-in                                         Good
    4  Built-in                                         Good
    Does it means that power supply 1 was removed? failed?
    Do you know about another command to see more details?
    Thanks,

    Hi All,
    Can you please help to fix the issue,
    sw03#sh env all
    FAN is OK
    TEMPERATURE is OK
    Temperature Value: 45 Degree Celsius
    Temperature State: GREEN
    Yellow Threshold : 58 Degree Celsius
    Red Threshold    : 68 Degree Celsius
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1  Built-in                                         Unavail
    SW  Status          RPS Name          RPS Serial#  RPS Port#
    1   Active          <>
    sw03#sh env st
    SWITCH: 1
    FAN is OK
    TEMPERATURE is OK
    Temperature Value: 45 Degree Celsius
    Temperature State: GREEN
    Yellow Threshold : 58 Degree Celsius
    Red Threshold    : 68 Degree Celsius
    POWER is FAULTY
    RPS is SUPPLYING
    As per the sh env stack, seem like power is faulty ?. Can Someone please tell how to rectify the problem.
    Madan

  • Cisco 3850 Dual Power Supply - One No Response

    Hey Guys,
    I am getting multiple switches on my network showing "power supply failure" from Solarwinds.
    I am running Cisco 3850s running v 03.02.03.SE cat3k_caa-universalk9 iOS, and they all have dual power supplies. When i do the sh env power, I get this output.
    SWITCH1#sh env power
    SW  PID                             Serial#     Status               Sys Pwr  PoE Pwr  Watts
    1A  PWR-C1-715WAC       xxxx           OK                 Good     Good           715
    1B  PWR-C1-715WAC       xxxx         No Response   Good     Good           715
    SWITCH2#sh env power
    SW  PID                              Serial#     Status           Sys Pwr    PoE Pwr     Watts
    1A  PWR-C1-715WAC       xxxx           OK                   Good     Good          715
    1B  PWR-C1-715WAC       xxxx         No Response     Good     Good          715
    When I physically go down to look at the switches, they have green lights, so they are receiving power, but I keep getting the PSU failure alerts.
    Do you think it is an iOS issue, and should I upgrade? Or has anyone else seen this?

    Hi,
    I think below Bug could match with your issue.
    "power supply B is not responding" reoccurring on Catalyst switches
    https://tools.cisco.com/bugsearch/bug/CSCun41735/?reffering_site=dumpcr
    And we can see workaround of this issue is HW workaround.
    Thanks,
    Jack

  • Ciscoview Cisco 6509 VSS power supply LED indicators incorrect

    Hello all
    i am experiencing the following problem.
    In the Ciscoview, the LED indicators of the power supply of Cisco 6509 VSS are represented incorrectly. All power inputs and fans are okay actually. however, in the ciscoview, there is only 1 green "INPUT OKAY" for each power supply. And "FAN OKAY" LEDS are off on Active chassis.
    Any assistance would be greatly appreciated.
    LMS 4.1
    IOS Version 12.2(50)SY1
    Device Package:
    38.
    Cat6000
    12.0
    Cat6000 Package
    39.
    Cat6000IOS
    37.0
    Cat6000IOS Device Package

    Check the PS at the back, is there a light?  If there's no light, then you need to RMA the PS as it could be faulty.
    If there's a light on the PS, then you need to RMA the switch. 

  • Cisco 7603-S power supply

    Hi,
    i have cisco 7603-S router with 1500W DC power supply. As per documentation, there is one input per power supply. I want to know the Electrical Cable specification (thickness of the cable in Sqmm)for the 1500W DC power supply, also type of lugs if required.
    Regards

    Hi Zabeel,
                       I did talk with TAC - per the engineer there are two bugs that cause the issue and one was fixed in 3.3.5 - so we upgraded all our 3850's to that code level. Unfortunately for us, that still didn't fix the issue. TAC suggested that it may be fixed in rev 3.7.0, but that has not officially been confirmed by Cisco's developers.
             We're waiting for the official "fix" before going through another round of switch upgrades.
            TAC did suggest reseating the power supply if you still have the issue after the upgrade to 3.3.5 - but that's not really an option for me since my switches are geographically spread out.
       HTH
                 Marty

  • Is power supply 3k-X 715W AC hot swappable on Cisco 3750X?

    Is power supply 3k-X 715W AC hot swappable on Cisco 3750X?
    Thanks
    Diego

    Sorry, found the answer http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst3750x_3560x/hardware/installation/guide/3750x_3560x_HIG/HIGFRU.html
    The power supply is hot-swappable. In some configurations, such as full PoE+ or power sharing mode, removing a power supply causes powered devices to shut down until the power budget matches the input power of a single power supply. To minimize network interruption, hot swap the power supply under these circumstances:
    –The switch is connected to an XPS 2200 and sufficient power is available.
    –The switch is in StackPower mode and sufficient power is available (Catalyst 3750-X only).
    –The switch is powered by other switches in a power stack, and no active backup is in progress.
    For the switch commands for displaying the available power budget, see the Catalyst 3750-X and 3560-X Software Configuration Guide.

  • Regarding Cisco 4500/6500 Power Supply

    Hi ,
    I am Rajesh, I want to know that can we check Cisco 4500/6500 power supply whether it is working or dead by connecting it directly with power source and without attching it to chassis.
    Regards,
    Rajesh

    Hi ,
    I am Rajesh, I want to know that can we check Cisco 4500/6500 power supply whether it is working or dead by connecting it directly with power source and without attching it to chassis.
    Regards,
    Rajesh

  • Cisco power supply and APC UPS question

    Good afternoon, I am running a 4507 with the Power Supples PWR-C45-2800ACV
    http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps4324/product_data_sheet09186a00801f3dd9.html
    Can I plug this power supply into this UPS unit?
    http://www.apc.com/products/resource/include/techspec_index.cfm?base_sku=SMX3000RMLV2UNC&tab=models

    Jason:
    My guess is that 2800w power supply is looking for two legs of AC in to make the DC stable on the switch.   I've installed a lot of 45XXx over the years but I never have more than 100 ports of active POE on them as most buildings have lots of computers and printers and a few VOIP phones and access points.  
    Now, those power supplies are pretty fault tolerent and well built.  They can take (probably) swing voltage from 40-240V and 50-60Hz.    You can wire up the L6-30 into the TWLK cable and only have 20A of 120V on one leg from the output of your UPS.     You just have a single 30A hot, neutral and ground and a dead leg for hot into the power supply.   You use half the power supply.  
    The capacitors on the power supply will just have to absorb that and deal with it.   That's their job.  Short term batteries. 
    One thing you need to realize is that you don't have to have two full-capacity 2800w circuits for the switch.   The 2800 is a reference number and that's based on a lot of inneffiencies in the entire system.  
    You've got at max a 2800w load and either 1 or two power supplies will feed it.    Two power supplies will be slightly less efficient than one but you're not pulling 5600w.   
    If you could, answer the questions above on the number of POE devices you've got and we can work a solution to solve the power to the switch and to your nodes.  
    You've got a lot of expensive, quality gear and the best solution isn't always to double up and re-buy what you've got.  
    I am going to recommend a metered PDU so that you can watch the amperage as when you approach the limit of what your wires can haul, you need to pay attention to the national electric code.
    If you can PM me, do.
    -Luke

  • Power supply of Cisco WVC210 Camera with batteries

    I want to use my new WVC210 Wireless-G PTZ Internet Video Camera on my wheeled robot, so I would like to provide a  separate power source for this camera.
    Can I use 4 "D" batteries for it? They give 6 V DC, not 5 V as written  on the camera.
    I've measured the voltage coming out from the power supply, which came  with the camera. In Switzerland it outputs 5.39 V DC.
    I am afraid 6 V DC may damage the camera. Or is it OK?
    If 6 V is not OK, then another possibility is 4 x 1.2 V DC researchable  batteries. But it gives only 4.8 V DC.
    Can camera be supplied with only 4.8 V DC? Or is it better to use 6 V DC?
    Or I shall build DC-DC converter outputting exactly 5 V?
    In specifications for the Cisco WVC210 it is written: "5V DC 2.0A switching power supply". But how tolerrant is the switching power supply? Will it work safely with 6 - 5.8 V?

    I'm afraid we can't recommend using any power source other than the AC adapter included with the camera.  Using anything else would likely void your warranty also.
    Regards,

Maybe you are looking for

  • Airplay not working with non-apple router

    I use an airport express only for playing music in a remote location. It stopped working after I switched my main wireless router from a Time Capsule to a Linksys running Tomato USB firmware. The Express is set up as "join a wireless network" with th

  • JSplitPane with 2 JScrollPanes sincroniced

    Hi everyone, I have a problem, and I haven't been able to solve it yet, this is it: I have a SplitPane, on its left side I have a jTable, and on its rigth side I have a jPanel with labels, I need them to have independent horizontal Scrolls but I need

  • FDF Form won't open

    I have a link created in DreamWeaver that directs the public to a pdf file. Once the form is completed and the hit the submit button it is then sent via email in the fdf format. I have one user you can not open the attachments once they have received

  • Error during release of production order - AFS Specific

    Hi SAP gurus, Iam getting error during release of production order in AFS specific system during COHV transaction. Error is ''Error calling ATP server'' and message no is AG022. But when we read the PP master data then this error is cleared and produ

  • With the update to 5 I lost the bookmark star in the tabs. Is there someway to get it back?

    I now have no bookmark star in the tabs. It was there until the update to Firefox 5. Would love to know a fix.