Cisco Blade Switch
I am having problems with configuring speed on uplink ports on cisco blade switches (Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class). I can configure fixed speed on uplink ports (Gi0/19-22) but after reload I am getting message that this command was rejected:
speed 1000
^
% Invalid input detected at '^' marker.
and then auto-1000 speed is specified.I need fixed speeds on those ports.What is strange that access ports (Gi0/1-18) dont have this problems.I excluded firmare problem,vlan,vtp negotation. The problem is still recouring even if I configure this ports only with speed comand and nothing more. Could someone give me some clues? Thanks
Checked that olso,ports are 10/100/1000/auto Base-TX with half/full/auto duplex, so it seems that it is not an issue. I am getting this problem after this communicate:
cisco 371098-001 (PowerPC405) processor (revision B0) with 118784K/12280K bytes
of memory.
Processor board ID FOC0948T07C
Last reset from power-on
1 Virtual Ethernet interface
24 Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 00:15:FA:D2:1A:00
Motherboard assembly number : 73-9666-09
Motherboard serial number : FOC09480QLE
Model revision number : B0
Motherboard revision number : A0
Model number : 371098-001
Daughterboard assembly number : 73-9697-04
Daughterboard serial number : FOC09480SJU
System serial number : FOC0948T07C
Top Assembly Part Number : 800-25741-01
Top Assembly Revision Number : C0
Version ID : V01
Daughterboard revision number : A0
Hardware Board Revision Number : 0x02
Switch Ports Model W Version SW Image
* 1 24 371098-001 12.2(25)SED CGESM-LANBASEK9-M
speed 1000
^
% Invalid input detected at '^' marker.
speed 1000
^
% Invalid input detected at '^' marker.
speed 1000
^
% Invalid input detected at '^' marker.
speed 1000
^
% Invalid input detected at '^' marker.
Press RETURN to get started!
Maybe there the answer lays. Do You know what is happeing then?
Similar Messages
-
Stacking with Cisco Blade Switches
Hi,
We have a HP p-class Blade System with two Cisco Gigabit Ethernet Switch Modules (Cisco IOS Release 12.2(25)SE) for every enclosure. My question is how I can stack the two blade switches (in the same enclosure) so that every HP blade server to be connected with the two switches in the active/standby state? In other words, can and how I make a port-channel which includes ports from the two switches?
Unfortunately I couldn't found any documentation for the purpose.Hi,
With the CGESM switches you have you cannot use 802.3ad teaming against the two blade switches. This is possible with the Cisco 3120 blade switches for HP c-class.
Now, in your case, you can use standard Active/Standby NIC teaming, where the active NIC of each server connects to one switch and the standby NIC connects to the other switch. Should a blade switch completely fail, all of the servers with their active NIC connected to the failed switch should see the link go down and switch over to the standby NIC on the second switch. This should work very well.
One problem that can happen however is that the blade switch itself does not completely fail. Instead maybe the blade switch uplink fails, or the upstream switch it is connected to fails. In this situation the server NIC does not experience a failure and continues to send traffic to the blade switch that does not have anywhere to send the traffic, a black hole. This is perhaps the problem you are seeing?
The fortunate thing is that Cisco has a solution to this problem called Trunk Failover with Link State Tracking. What this allows you to do is to tell the blade switch that if it experiences a failure on its uplinks that it should also bring down the links to the servers as well. This will cause the servers to see a failure on their active NIC and perform a switchover to the second blade switch.
I looked up your switch and found that your 12.2(25)SE1 code does not support this feature. You will need to upgrade to 12.2(25)SEE4 and you will be able to configure this on your switches.
Here is a link to see how this configuration works:
http://www.cisco.com/en/US/docs/switches/blades/3020/software/release/12.2_25_sef1/configuration/guide/swethchl.html#wp1346176
Hope this helps.
If so please rate my posts.
Thanks,
Brad -
Cisco 3020 Blade Switch gecrashed
Hi,
One of our Blade switches has crashed, error log as follows,
*Mar 1 05:31:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan550, changed state to up
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: System previously crashed with the following message:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Cisco IOS Software, CBS30X0 Software (CBS30X0-LANBASE-M), Version 12.2(25)SEF1, RELEASE SOFTWARE (fc3)
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Copyright (c) 1986-2006 by Cisco Systems, Inc.
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Compiled Tue 23-May-06 15:26 by antonino
.Dec 26 22:21:20: %PLATFORM-1-CRASHED:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Program Exception (0x0700)!
.Dec 26 22:21:20: %PLATFORM-1-CRASHED:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: SRR0 = 0x003C38AC SRR1 = 0x00029210 SRR2 = 0x00451BDC SRR3 = 0x00021200
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: ESR = 0x08000000 DEAR = 0x00000000 TSR = 0x84000000 DBSR = 0x00000000
.Dec 26 22:21:20: %PLATFORM-1-CRASHED:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: CPU Register Context:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Vector = 0x00000700 PC = 0x003C38AC MSR = 0x00029210 CR = 0x20000008
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: LR = 0x003C38A4 CTR = 0x0027C814 XER = 0x60000020
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R0 = 0x003C38A4 R1 = 0x014D6650 R2 = 0x00000000 R3 = 0x00000004
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R4 = 0x013A1E60 R5 = 0x00000001 R6 = 0x00433EDC R7 = 0x00000004
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R8 = 0x00029210 R9 = 0x00000002 R10 = 0x01220000 R11 = 0x00F60000
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R12 = 0x0070D567 R13 = 0x00110000 R14 = 0x00000002 R15 = 0x00000000
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R16 = 0x00000000 R17 = 0x00000000 R18 = 0x01220000 R19 = 0x01220000
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R20 = 0x00F0CF5C R21 = 0x012D27D0 R22 = 0x01220000 R23 = 0x0187F530
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R24 = 0x00000000 R25 = 0x0004073F R26 = 0x01220000 R27 = 0xEF180E50
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: R28 = 0xEF19007A R29 = 0x00000000 R30 = 0x01220000 R31 = 0x00000000
.Dec 26 22:21:20: %PLATFORM-1-CRASHED:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Stack trace:
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: PC = 0x003C38AC, SP = 0x014D6650
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 00: SP = 0x014D6678 PC = 0x003C38A4
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 01: SP = 0x014D6680 PC = 0x003C3964
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 02: SP = 0x014D66A0 PC = 0x004B97AC
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 03: SP = 0x0126264C PC = 0x00451060
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 04: SP = 0x0126265C PC = 0x00451008
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 05: SP = 0x0126267C PC = 0x0045342C
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 06: SP = 0x01262684 PC = 0x004538F8
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 07: SP = 0x012626D0 PC = 0x00451110
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 08: SP = 0x0187F298 PC = 0x0000D3CC
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 09: SP = 0x0187F2A0 PC = 0x002659D8
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 10: SP = 0x0187F4D0 PC = 0x00423870
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 11: SP = 0x0187F4E8 PC = 0x00AAF21C
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 12: SP = 0x0187F528 PC = 0x006C9400
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 13: SP = 0x0187F5F8 PC = 0x006C8E04
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 14: SP = 0x0187F610 PC = 0x006C8A64
.Dec 26 22:21:20: %PLATFORM-1-CRASHED: Frame 15: SP = 0x0187F638 PC = 0x006C848C
.Dec 26 22:21:20: %PLATFORM-1-CRASHED:
Dec 27 09:10:14: %SYS-5-CONFIG_I: Configured from console by vty0 (172.22.25.22)
Please help to fixed this issue,
Asa,Signal = 4, Vector = 0x700
Thank you very much for the output. They were very helpful.
Here's the story, the blade has been crashing because of the error "Signal = 4". I have never seen something like this so the only thing I can tell you is that this is a code that simply means "Illegal Opcode Exception". It could mean that you are running an old IOS and you're hitting a bug.
You can contact Cisco TAC and get them to analyze the crashinfo files. You can put this thread into the TAC Case so you don't need to repeat your story all over again. -
Cisco Catalyst Blade Switch 3020
Information about the Cisco Catalyst Blade Switch 3020
Does it support TCP SYN Flooding Attacks Mitigations Techniques
As per the Request for Comments: 4987Most of the common DOS attack mitigation strategies (good overview here) are configurable on the CBS 3020. There's no "one step lockdown" like the autosecure feature on routers but the configuration guide covers all of the details on setting the individual mechanisms (DHCP Snooping, DAI, IP source guard, etc.) you may wish to employ.
-
"Cisco Catalyst Blade Switch 3020 for HP" Best Practices
Hi all,
Here we use this blade switch cluster for the Data Center server farm. Here we noticed some network traffic delay. when I monitor the up link I can see there is not much traffic in the link. So doubt about the traffic delay. If anyone can help me on this it would be great...
Thanks in Progress.....
ChandanaHere in the "blade switch for HP" a request processing application is running in a server. when we use the same type server stand alone with a separate switch it processes 80,000 requests per 4 hours. But when this blade server in the blade switch it only processes near 6,000 requests per 4 hours.
That what I mean like "Network delay"...
That is what I cannot understand.
I have attached the current configuration of the blade switch so you can go through it.
Is there any best practices specific to that type of blade switch that should enable?
Thanks for your help
regards
Chandana -
Two forwarding root ports on cisco 3120 blade switch.
Hi,
<br />
<br />After upgrading blade switch 3120 to 12.2(46)SE, I could see two root ports in which both are forwarding.
<br />
<br />Te1/0/1 Root FWD 2000 128.27 P2p
<br />Te2/0/1 Root FWD 2000 128.81 P2p
<br />
<br />Where as STP should've kept the other root port as blocked state and named it has Alternate port.
<br />Also started seeing Mac flap messages.
<br />As soon as IOS was downgraded to 12.2(40)EX3, Problem was solved, even messages were stoped.
<br />Seems to be bug, but couldn't get any.
<br />Hi Rob,
I have faced this issue with many enclosures so far and the only option left here is, you need to reboot the enclosure.
This is an issue with the IOS code and you have to open a case with HP to get the appropriate IOS ver. Probably 15.0 code has this issue resolved and I haven't seen this issue further after the Upgrade.
Thanks,
Sagar -
I am deploying HP BladeSystem C Class with Cisco 3020 Ethernet blade switches connecting to Catalyst 6500 at the aggregation layer. What are my best options for managing layer 2, VLANs, etc, across the Cat6K and 3020 switches?
Matt,
Great catch, thank you!
Switch#show link state group detail
Link State Group: 1 Status: Disabled, Up
Upstream Interfaces : Po1(Up)
Downstream Interfaces : Gi0/1(Up) Gi0/2(Up) Gi0/3(Up) Gi0/4(Up) Gi0/5(Up)
Gi0/6(Up) Gi0/7(Up) Gi0/8(Up) Gi0/9(Up) Gi0/10(Up)
Gi0/11(Up) Gi0/12(Up) Gi0/13(Dwn)
Link State Group: 2 Status: Disabled, Down
Upstream Interfaces :
Downstream Interfaces :
(Up):Interface up (Dwn):Interface Down (Dis):Interface disabled
Switch#conf t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#link state trac
Switch(config)#link state track 1 ?
Switch(config)#link state track 1
Switch(config)#end
Switch#show link state group detail
Link State Group: 1 Status: Enabled, Up
Upstream Interfaces : Po1(Up)
Downstream Interfaces : Gi0/1(Up) Gi0/2(Up) Gi0/3(Up) Gi0/4(Up) Gi0/5(Up)
Gi0/6(Up) Gi0/7(Up) Gi0/8(Up) Gi0/9(Up) Gi0/10(Up)
Gi0/11(Up) Gi0/12(Up) Gi0/13(Dwn)
Link State Group: 2 Status: Disabled, Down
Upstream Interfaces :
Downstream Interfaces :
(Up):Interface up (Dwn):Interface Down (Dis):Interface disabled
Switch#
Scott
www.xpresslearn.com -
MDS FC Blade Switch for IBM - Licensing
Hi,
our customer has got installed the 20-port-switch of the "Cisco MDS Fibre Channel Blade Switch for IBM BladeCenter". He wants to change some of the links now. For that reason he asked me:
- Is there a fix relationship between a port and a license?
- Can we use any port as long as we fall below the number of licenses?
Thanks in advance and regards
MatthiasHello Matthias,
Cisco Fabric Switch for IBM BladeCenter (20 ports; 14 internal 2/4 Gbps, and 6 external full-rate ports) licenses for internal ports are allocated as the ports come up. Licenses for external ports are allocated sequentially.
Refer "On-Demand Port Licensing" section on CLI guide here :
http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/configuration/guides/cli_3_3/ondport.html
Customer can select the specific external ports he wants licensed.
switch# config t
switch(config)# interface fc1/1
switch(config-if)#port-license acquire
Thanks,
Prateek -
Etherchannel and STP on HP Blade Switches
Hi Guys,
I have a 6509 with and etherchannel connection to an HP Blade switch... the channel is made up of two phy ports between the two switches...
When I try ti bring up the link, the 6509 ports go into err-disable and i get the message below.
I have done all (I think?) checks that there is to ensure etherchannle compatibility and STP stuff but still no luck...
can anyone suggest soemthing I do ro check that might shed light on this...
thanks
2005 Jun 26 02:53:06 AEDT +10:00 %ETHC-5-PORTTOSTP:Port 10/24 joined bridge port 10/24-25
2005 Jun 26 02:53:06 AEDT +10:00 %SPANTREE-6-PORTLISTEN: Port 10/24-25 (agPort 14/45) state in VLAN 144 changed to listening
2005 Jun 26 02:53:20 AEDT +10:00 %SPANTREE-6-PORTLEARN: Port 10/24-25 (agPort 14/45) state in VLAN 144 changed to learning
2005 Jun 26 02:53:35 AEDT +10:00 %SPANTREE-6-PORTFWD: Port 10/24-25 (agPort 14/45) state in VLAN 144 changed to forwarding
2005 Jun 26 02:54:23 AEDT +10:00 %SPANTREE-2-CHNMISCFG: STP loop - channel 10/24-25 is disabled in vlan/instance 144
2005 Jun 26 02:54:23 AEDT +10:00 %SPANTREE-2-CHNMISCFG2: BPDU source mac addresses: 00-03-fe-af-d0-b5, 00-11-f9-21-56-00
2005 Jun 26 02:54:23 AEDT +10:00 %ETHC-5-PORTFROMSTP:Port 10/24 left bridge port 10/24-25Hi ankur,
thanks for your response. currently the etherchannel operatiosn mode on the 6509 is set to manual, which is the case globally for the 6509 and we have 50 pairs of this blade switch running on this 6509... I don't think that that is the cuase of this issue since this is the only one not forming the channel and goes into err-disable...
the blades also have similar configs in them...
the only thing I see different on ports 10/24-25 is that it has bpdu-guard set to disable while the rest are set to default... could this make a diffrence?
also, does the order of enabling the cisco end and the HP blade end make a difference? i.e. should I bring up one first than the other?
the thing is I cannot "experiment" fully as this is a full prod network...
Any input si appreciated... -
Catalyst Blade Switches 3020 For HP Blade Chassis
I was trying to access Catalyst Blade Switch 3020 through serial port to reset the lost password. This Switch is plug-in to HP c7000 Chassis. I followed the instruction from Cisco documentation for this password re-set process as follows.
{ Step 1 Connect a terminal or PC with terminal-emulation software to the switch console port.
Step 2 Set the line speed on the emulation software to 9600 baud.
Step 3 Push the release latch on the front of the switch to the open position.
Step 4 Pull the switch partially out of the module bay until the power disconnects, and then push it in again. The switch restarts when it reseats in the server chassis. The switch performs POST after power is applied.
Step 5 Push the release latch on the front of the switch to the closed position.
Step 6 Within 15 seconds, press the Mode button while the System LED is still flashing green. Continue pressing the Mode button until the System LED turns briefly amber and then solid green; then release the Mode button.
------- Step 6 did not work. System LED neither flashing nor in Solid state. I can not connect through Serial port any more! Any help.....Here in the "blade switch for HP" a request processing application is running in a server. when we use the same type server stand alone with a separate switch it processes 80,000 requests per 4 hours. But when this blade server in the blade switch it only processes near 6,000 requests per 4 hours.
That what I mean like "Network delay"...
That is what I cannot understand.
I have attached the current configuration of the blade switch so you can go through it.
Is there any best practices specific to that type of blade switch that should enable?
Thanks for your help
regards
Chandana -
Link-state protocol on blade switches
Hi,
Can anyone confirm is after an uplink is reestablished the down stream interfaces are automatically restored when using link-state protocol?
The documentation states the downstream ports in a group are put in error disable state but doesn't say if they are automatcally made up when the upstream interface comes back up. This refers to Cisco blade 3020 switches running 12.2.25
http://www.cisco.com/c/en/us/td/docs/switches/blades/3020/software/release/12-2_55_se/configuration/guide/3020_scg/swethchl.html#wp1346176
Thanks
KenLink state tracking, also known as trunk failover, provides Layer 2 redundancy in the network when used in conjunction with server network interface card (NIC) adapter teaming. Link-state tracking is used to mirror the state of the ports that carry upstream traffic from connected hosts and servers, and to allow the failover of the server traffic to an operational link on another Cisco Ethernet switch. Check out the following link for more information on link state tracking :
http://www.cisco.com/en/US/products/ps6406/products_configuration_guide_chapter09186a00805a75e0.html#wp1285238
Hope this helps. -
Nexus5k - LACP towards HP blades switch(and nortel blade switch)
Hi
First I have to say this is not the first time i'm working with these old switches and not the first time i've configured LACP on them.
So I did the config on the blade switch , enabled LACP, the uplink ports as members and tagged.
Created port-channel on the nexus side.
when i try to bring up the ports on the Cisco Nexus 5k this is the errors I get. this is fot the HP blade:
2013 Jun 11 14:44:03 dist4 %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: Ethernet171/1/7: Ethernet171/1/7 is suspended
2013 Jun 11 14:44:03 dist4 %LACP-FEX171-3-LACP_MEM_PC_MISCFG: LACP misconfiguration detected on Ethernet171/1/7(0x1faa0180): (Member channel group id: 31-1, does not match PC group id: 31-1
0)
2013 Jun 11 14:44:04 dist4 %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: Ethernet172/1/7: Ethernet172/1/7 is suspended
2013 Jun 11 14:44:04 dist4 %LACP-FEX172-3-LACP_MEM_PC_MISCFG: LACP misconfiguration detected on Ethernet172/1/7(0x1fab0180): (Member channel group id: 31-1, does not match PC group id: 31-1
0)
I had one port-channel for a switch that came up with no problems. I compared the config but could not identify the issue.the config is very similar.
has anyone encountered these errors or similar before? if yes, what am I missing? and also what does it mean when it says "
Member channel group id: 31-1, does not match PC group id: 31-10) ?
Thanks,
MaryMarcel,
Thank you for your reply.
I tried again right now with the command you suggested but still no luck.
we have so many more hp switches with the similar config that are working fine. I just can't figure out why these 3 switches are having issues.
my current config on the member port is as below
interface Ethernet171/1/36
description WINBL1-NFS2:P2
lacp rate fast
switchport mode trunk
switchport trunk allowed vlan 410,412
spanning-tree bpdufilter enable
flowcontrol send off
channel-group 30 mode active
2013 Jun 13 11:00:51 dist4 %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: Ethernet171/1/36: Ethernet171/1/36 is suspended
2013 Jun 13 11:00:51 dist4 %LACP-FEX171-3-LACP_MISCFG: LACP misconfiguration detected on Ethernet171/1/36(0x1faa08c0): (Member system mac does not match PC system mac)
2013 Jun 13 11:00:52 dist4 %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: Ethernet172/1/36: Ethernet172/1/36 is suspended
2013 Jun 13 11:00:50 dist4 %LACP-FEX172-3-LACP_MISCFG: LACP misconfiguration detected on Ethernet172/1/36(0x1fab08c0): (Member system mac does not match PC system mac)
Thanks,
Mary -
Thanks to confirm AP521 NEED Cisco 520 Switch
Thanks to confirm that AP521 need a Cisco 520 Switch. And that it cannot works without Cisco product.
1. Yes...you configure the IP address via the IBM blade center Management Module web interface.
2. Depending on the version of firmware on the swtich module, the FM may or may not be inluded. The device manager client will be there and can be downloaded via the web connection. I believe that with 4.x and later code, FM is no longer included in the switch firmware.
3. Yes the default user id is USERID and PASW0RD (zero not 0) from this user you can add aditional user/passwords for management.
4. Yes, you can upgrade via TFTP server or diretly via Fabric Manager, there is no mechanism for using Device Manager to upgreade code.
5. Nothing special needs to be done. By defauylt, the ports EXT0, EXT15, and EXT16 are licensed. If you need additional external ports, you must license the additional 10 ports on the module.
Hope this helps,
Mike -
WWN does not show up on Cisco SAN Switch
We use Cisco SAN Switches MDS 9134 and MDS9222i with NX-IOS 4.2.(3). Our HP c7000 blade enclosure is connect through a Fibre Channel Virtual Connect Card to the SAN switches. For so far is everything working Oke. Now is the problem when I connect the 8th and 9th Blade Server (BL860c i2 Integrity Server) to the c7000 enclosure non of the wwn's show up on the Cisco Switch. Neither on the MDS9134 as the MDS9222i.Firmware on the HP Blade is up to date. The Onboard Administrator show that the HBA's are logged-in to Virtual Connect.
Does anyone know solution for this issue.
Best Regards,
RobertHi Robert,
The output of "show flogi database" will show you all the wwn's of devices connected directly to a particular
switch.
Is NPV involved in your topology?
Regards,
Ken -
Packet loss when pinging from/to a cisco 3560e switch
I see Packet loss when pinging from/to a cisco 3560e switch. CPU utilization is normal.
Switches are running with IOS c3560e-universalk9-mz.122-35.SE5.bin.
Packet loss is observed for all the devices irrespective of directly connected or remote devices.
If i do self pinging, there are no packet loss.
I don't see any error on interface.
Can anyone please help me in resolving this issue.TCB Local Address Foreign Address (state)
03737C48 10.47.0.229.60053 10.41.81.55.49 CLOSEWAIT
039ACDC4 10.47.0.229.61929 10.41.35.250.49 CLOSEWAIT
03B316C0 10.47.0.229.27544 10.41.81.55.49 CLOSEWAIT
038228F0 10.47.0.229.16506 10.41.35.250.49 CLOSEWAIT
039C3D04 10.47.0.229.15207 10.41.81.55.49 CLOSEWAIT
039A9BD0 10.47.0.229.52983 10.41.81.55.49 CLOSEWAIT
0394152C 10.47.0.229.22425 161.61.35.250.49 CLOSEWAIT
037D811C 10.47.0.229.21117 10.41.81.55.49 CLOSEWAIT
039C12BC 10.47.0.229.37437 10.41.81.55.49 CLOSEWAIT
03933B84 10.47.0.229.34085 161.61.35.250.49 TIMEWAIT
03B32340 10.47.0.229.45729 10.41.81.55.49 CLOSEWAIT
038247D0 10.47.0.229.32816 10.41.81.55.49 CLOSEWAIT
039A92D8 10.47.0.229.38680 161.61.35.250.49 CLOSEWAIT
037370F0 10.47.0.229.13212 10.41.81.55.49 CLOSEWAIT
037D85F0 10.47.0.229.38728 10.41.81.55.49 CLOSEWAIT
03B2B284 10.47.0.229.23428 10.41.81.55.49 CLOSEWAIT
03B2ADB0 10.47.0.229.56836 10.41.81.55.49 CLOSEWAIT
0394BFF0 10.47.0.229.23257 161.61.35.250.49 CLOSEWAIT
036604DC 10.47.0.229.44437 10.41.81.55.49 CLOSEWAIT
0394C700 10.47.0.229.22 192.37.184.211.61639 ESTAB
039B9A68 10.47.0.229.20543 10.41.81.55.49 CLOSEWAIT
03739B28 10.47.0.229.15392 10.41.81.55.49 CLOSEWAIT
TCB Local Address Foreign Address (state)
0392EA48 10.47.0.229.13862 10.41.81.55.49 CLOSEWAIT
0365E23C 10.47.0.229.27856 10.41.81.55.49 CLOSEWAIT
03817C0C 10.47.0.229.64929 10.41.81.55.49 CLOSEWAIT
039357C8 10.47.0.229.22088 10.41.81.55.49 CLOSEWAIT
037375C4 10.47.0.229.21832 10.41.81.55.49 CLOSEWAIT
039C20E8 10.47.0.229.18169 10.41.81.55.49 CLOSEWAIT
03716D08 10.47.0.229.61993 10.41.81.55.49 CLOSEWAIT
039A74E4 10.47.0.229.62948 10.41.81.55.49 CLOSEWAIT
03655480 10.47.0.229.14052 10.41.81.55.49 CLOSEWAIT
039407F0 10.47.0.229.49643 161.61.35.250.49 CLOSEWAIT
039A53AC 10.47.0.229.13233 10.41.81.55.49 CLOSEWAIT
03739FFC 10.47.0.229.16605 10.41.81.55.49 CLOSEWAIT
039B82B8 10.47.0.229.16458 10.41.35.250.49 CLOSEWAIT
039BEBA4 10.47.0.229.64377 10.41.81.55.49 CLOSEWAIT
03741980 10.47.0.229.13866 10.41.81.55.49 CLOSEWAIT
03B3ABF8 10.47.0.229.19365 10.41.81.55.49 CLOSEWAIT
039B5810 10.47.0.229.24768 10.41.81.55.49 CLOSEWAIT
03956E48 10.47.0.229.55980 161.61.35.250.49 CLOSEWAIT
03946820 10.47.0.229.65053 161.61.35.250.49 CLOSEWAIT
037DBE94 10.47.0.229.15283 10.41.81.55.49 CLOSEWAIT
039A4854 10.47.0.229.48562 10.41.81.55.49 CLOSEWAIT
TCB Local Address Foreign Address (state)
03B33320 10.47.0.229.29803 10.41.81.55.49 CLOSEWAIT
03B3B79C 10.47.0.229.12142 10.41.81.55.49 CLOSEWAIT
03713C9C 10.47.0.229.63799 10.41.81.55.49 CLOSEWAIT
039BBECC 10.47.0.229.14763 10.41.81.55.49 CLOSEWAIT
03656E40 10.47.0.229.16357 10.41.81.55.49 CLOSEWAIT
0362A73C 10.47.0.229.62450 10.41.81.55.49 CLOSEWAIT
039B878C 10.47.0.229.64402 161.61.35.250.49 CLOSEWAIT
03826CFC 10.47.0.229.16108 10.41.81.55.49 CLOSEWAIT
03B2CA34 10.47.0.229.17634 10.41.81.55.49 CLOSEWAIT
03AD78D0 10.47.0.229.15249 161.61.35.250.49 CLOSEWAIT
03AD967C 10.47.0.229.20389 161.61.35.250.49 CLOSEWAIT
03B2C560 10.47.0.229.37079 10.41.81.55.49 CLOSEWAIT
039C5128 10.47.0.229.24711 10.41.81.55.49 CLOSEWAIT
03822F74 10.47.0.229.54866 10.41.81.55.49 CLOSEWAIT
0372C5FC 10.47.0.229.13298 10.41.81.55.49 CLOSEWAIT
0372D278 10.47.0.229.12407 10.41.81.55.49 CLOSEWAIT
039A33D0 10.47.0.229.36573 10.41.81.55.49 CLOSEWAIT
039BCEF8 10.47.0.229.53853 10.41.81.55.49 CLOSEWAIT
039C02D8 10.47.0.229.53725 10.41.81.55.49 CLOSEWAIT
039B5CE4 10.47.0.229.58027 10.41.81.55.49 CLOSEWAIT
0381866C 10.47.0.229.17100 10.41.81.55.49 CLOSEWAIT
TCB Local Address Foreign Address (state)
039BB374 10.47.0.229.53148 10.41.81.55.49 CLOSEWAIT
03AD3634 10.47.0.229.19716 161.61.35.250.49 CLOSEWAIT
0362DAA4 10.47.0.229.19479 10.41.81.55.49 CLOSEWAIT
0365AE60 10.47.0.229.62209 10.41.81.55.49 CLOSEWAIT
0362D5D0 10.47.0.229.41327 10.41.81.55.49 CLOSEWAIT
037D7C48 10.47.0.229.58283 10.41.81.55.49 CLOSEWAIT
03955474 10.47.0.229.33810 161.61.35.250.49 CLOSEWAIT
0373B15C 10.47.0.229.23331 10.41.81.55.49 CLOSEWAIT
036628D0 10.47.0.229.46856 10.41.81.55.49 CLOSEWAIT
03819584 10.47.0.229.19861 10.41.81.55.49 CLOSEWAIT
0394D000 10.47.0.229.64732 10.41.35.250.49 CLOSEWAIT
0394B760 10.47.0.229.19967 161.61.35.250.49 CLOSEWAIT
039B6BD4 10.47.0.229.40096 10.41.81.55.49 CLOSEWAIT
03AD7150 10.47.0.229.65184 10.41.35.250.49 CLOSEWAIT
039BC3A0 10.47.0.229.64702 10.41.81.55.49 CLOSEWAIT
03B3A724 10.47.0.229.60399 10.41.81.55.49 CLOSEWAIT
037145E0 10.47.0.229.43951 10.41.81.55.49 CLOSEWAIT
03955EDC 10.47.0.229.29015 161.61.35.250.49 TIMEWAIT
0365FB34 10.47.0.229.13961 10.41.81.55.49 CLOSEWAIT
03828D54 10.47.0.229.12743 10.41.81.55.49 CLOSEWAIT
037DB40C 10.47.0.229.23708 10.41.81.55.49 CLOSEWAIT
TCB Local Address Foreign Address (state)
039AF814 10.47.0.229.15100 10.41.81.55.49 CLOSEWAIT
0392E344 10.47.0.229.23399 10.41.35.250.49 CLOSEWAIT
0393DC3C 10.47.0.229.15393 161.61.35.250.49 CLOSEWAIT
03AD85D0 10.47.0.229.40932 161.61.35.250.49 TIMEWAIT
039574CC 10.47.0.229.25935 10.41.35.250.49 CLOSEWAIT
03738B74 10.47.0.229.58656 10.41.81.55.49 CLOSEWAIT
039AD91C 10.47.0.229.56760 10.41.81.55.49 CLOSEWAIT
03B3BC70 10.47.0.229.15058 10.41.81.55.49 CLOSEWAIT
03B2DC54 10.47.0.229.51131 161.61.35.250.49 CLOSEWAIT
03B393F0 10.47.0.229.11957 10.41.35.250.49 CLOSEWAIT
039B2610 10.47.0.229.33728 10.41.81.55.49 CLOSEWAIT
03B311EC 10.47.0.229.18047 10.41.81.55.49 CLOSEWAIT
039A8E04 10.47.0.229.52022 161.61.35.250.49 CLOSEWAIT
0365D460 10.47.0.229.12241 10.41.81.55.49 CLOSEWAIT
03B33E78 10.47.0.229.47640 10.41.81.55.49 CLOSEWAIT
0372C128 10.47.0.229.60323 10.41.81.55.49 CLOSEWAIT
03661CD8 10.47.0.229.39923 10.41.81.55.49 CLOSEWAIT
0393C73C 10.47.0.229.41864 10.41.35.250.49 CLOSEWAIT
03829584 10.47.0.229.56673 161.61.35.55.49 CLOSEWAIT
0362AC10 10.47.0.229.31952 10.41.81.55.49 CLOSEWAIT
039BF078 10.47.0.229.22636 10.41.81.55.49 CLOSEWAIT
TCB Local Address Foreign Address (state)
0365CF8C 10.47.0.229.14476 10.41.81.55.49 CLOSEWAIT
039B443C 10.47.0.229.59226 10.41.81.55.49 CLOSEWAIT
0393E794 10.47.0.229.56282 10.41.35.250.49 CLOSEWAIT
03657740 10.47.0.229.25769 10.41.81.55.49 CLOSEWAIT
03B2F6E8 10.47.0.229.19328 10.41.81.55.49 CLOSEWAIT
0373AC88 10.47.0.229.25766 10.41.81.55.49 CLOSEWAIT
039B213C 10.47.0.229.28882 10.41.81.55.49 CLOSEWAIT
039C07AC 10.47.0.229.38201 10.41.81.55.49 CLOSEWAIT
03AD8DD0 10.47.0.229.23002 10.41.35.250.49 CLOSEWAIT
03739048 10.47.0.229.29572 10.41.35.250.49 CLOSEWAIT
039BA464 10.47.0.229.32273 10.41.81.55.49 CLOSEWAIT
03B31E6C 10.47.0.229.32521 10.41.81.55.49 CLOSEWAIT
0365EBE0 10.47.0.229.41319 10.41.81.55.49 CLOSEWAIT
03938804 10.47.0.229.62841 10.41.35.250.49 CLOSEWAIT
039A1AF8 10.47.0.229.12758 10.41.81.55.49 CLOSEWAIT
039B7DE4 10.47.0.229.20921 10.41.81.55.49 CLOSEWAIT
036549F8 10.47.0.229.51903 10.41.81.55.49 CLOSEWAIT
03714CC8 10.47.0.229.45145 10.41.81.55.49 CLOSEWAIT
037425F8 10.47.0.229.56492 10.41.81.55.49 CLOSEWAIT
03B39D74 10.47.0.229.18174 10.41.81.55.49 CLOSEWAIT
Maybe you are looking for
-
Top 10 feature requests for reliability
As per the Terms of Use: Post constructive comments and questions. Unless otherwise noted, your Submission should either be a technical support question or a technical support answer. Feedback about new feature requests or product enhancements are we
-
Adobe Document Services Architecture NW04s
All, I am working at a customer that will be using Adobe Document Services for interactive forms. The customer has several existing SAP applications but for this project it was recommended to configure the ADS on the SRM server (java stack is require
-
Undefined method addEventlistener
ERRORS ON LINE 10 AND 11 1061: Call to a possibly undefined method addEventlistener through a reference with static type FunButton. package import flash.display.MovieClip; import flash.events.MouseEvent; public class FunButton extends MovieClip publi
-
Exception value in early warning system.
Dear all, We are using R/3 4.7. My user has a condition in which for every 10,000 numbers made as goods reciept from production (101) movement , system should trigger a mail to the respective user i.d. I tried to create this condition using early war
-
RE: (forte-users) Distributing library - What could preventmy li b fro
Hi Jean.. I remotely remember seeing this kind of a problem before. I think you can start by cleaning your environment. You can do this by: 1) Exporting your environment definition from econsole or using escript. The .edf file goes into the forte_roo