Dear team,
we are facing problem in cisco catalyst switch, actually we are using Cisco catalyst 4500e switch, Two month back we upgrade IOS from "cat4500e-ipbasek9-mz.150-2.SG" to cat4500e-ipbasek9-mz.152-2.E1.bin “since i upgrade new IOS that  was running perfectly,  but last two weeks back unexpectedly switch was rebooted and today also we faced the same problem. here i enclosed the tech support details. kindly check and suggest me the correct solution. 
  Is there in any bug is there?...... How can we clarify whether the switch is ok on that IOS.....
 please suggest me the right IOS image for my cisco catalyst 4500e switch

Hi Ashok,
Looks 15.2.2E2 has the fix. you could try upgrading to it.
Hope this helps.
Please do remeber to rate all useful posts.
Thanks,
Madhu.

Similar Messages

  • Cisco Catalyst 4500X

    I want to buy Cisco Catalyst 4500-X-16SFP+ and upgrade the license to Enterprise service. But license description show "IP Base to Ent. Services license for 16 Port Catalyst 4500-X". Is it means that only 16 port is Enterprise Service? If I add more 8 Ports module ,can it use Ent Service?
    Please kindly advise.
    Thanks,
    Mano

    Is it means that only 16 port is Enterprise Service?
    The license is in blocks of 16- or 32 ports.  Let's say you purchase an Enterprise license for 16-ports and you got an optional 8-port module.  You purchase an additional license of "C4500X-16P-IP-ES" and this allows you an additional 16-ports of license.  You can't purchase a license for only 8 ports.
    Cisco Catalyst 4500E Supervisor 7-E and 7L-E and Cisco Catalyst 4500-X Series Software Activation Licensing Deployment Guide

  • Idsm2 reboot unexpectedly

    Hi,
    We have one Catalyst 6509 with IDSM2, and the IDSM2 reboot unexpectedly. The error message is :
    Nov 17 22:32:47: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Module not responding to Keep Alive polling)
    Nov 17 22:32:48: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Module not responding to Keep Alive polling)
    Nov 17 22:36:21: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimum Diagnostics...
    Nov 17 22:36:22: %MLS_RATE-4-DISABLING: The Layer2 Rate Limiters have been disabled.
    Nov 17 22:36:22: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
    Nov 17 22:36:23: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
    Nov 20 18:47:26: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Module not responding to Keep Alive polling)
    Nov 20 18:47:26: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Module not responding to Keep Alive polling)
    Nov 20 18:51:00: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimum Diagnostics...
    Nov 20 18:51:01: %MLS_RATE-4-DISABLING: The Layer2 Rate Limiters have been disabled.
    Nov 20 18:51:01: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
    Nov 20 18:51:01: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
    It occured several times before 11/17 and I have tried to reseat the module before, but the IDSM2 reboot again. The IOS version of supervisor engine is s72033-ps-mz.122-18.SXD5.bin, The IDSM2 software version is 6.0(5)E2. Please help to diagnosis this problem. Shall I upgrade IOS of supervisor engine or IDSM or need RMA?
    Best Regards,
    Jackson Ku

    Agreed, this likely needs to have a TAC case opened for an RMA -- especially if a re-seat of the module has already been attempted.  Any time you're seeing the switch cut off power to the module over multiple insertions, that's not a good thing.
    I just had this happen to a FWSM last week, and re-seating the module didn't work for me, either.
    You can read more about the error message here:
    http://www.cisco.com/en/US/partner/products/hw/switches/ps700/products_tech_note09186a00801b42bf.shtml
    WorkaroundA simple reseat of the module corrects this issue 90 percent of the time. If you reseat the module, it realigns the switch fabric and ensures a firm connection to the backplane.

  • Cisco Catalyst 3850 as ntp master

    Hi All,
    I have 2 x Cisco Catalyst 3850 stacked together. What are your recommendations if I use the C3850 as a ntp master for all edge switches connected in my network? All edge switches must be authenticated if it needs NTP sychronization. But other than that, what are the downsides?
    For example,
    1. I heard that switches do not have an internal clock so is a poor device to be a centralized NTP master.
    2. I have also read that switches also have slow CPU processors that may lack the processing required.
    3. Its NTP sychronization will use external NTP servers which are resolved into IP addresses (e.g. pool.ntp.org). IP address can change. What other more reliable NTP sources are there?
    4. Any other thoughts and comments are most welcome.

    Firstly, DO NOT use the command "ntp master".  Cisco do not recommend using this commands because this will confuse the NTP propagation inside the network.  
    Next, all Cisco devices do not have a dedicated clock.  All appliances need to get SNTP/NTP time synch from somewhere.  This "somewhere" could either be a dedicated GPS-based NTP server and/or a time synch somewhere out in the internet.  
    You can also use the command "ntp update-calendar".  This new command allows appliances to take regular "snapshot" of the time and save it into the NVRAM.  In case there was a reboot or a power failure, the appliance's time is not too far away instead of waiting 5 to 10 minutes for SNTP/NTP to synch.

  • I cannot connect by console port to Cisco Catalyst 3750 using ethernet to USB.

    Hello. I have one Cisco Catalyst 3750 switch, and two 2950 switches. I am trying to reset their settings using a console cable with a trendnet Ethernet to USB adapter. When I try loading hyperterm or putty on com3 there is no signal. I have the communication port setting on com3. I don't know what the old settings are, and they can be reset. I get connectivity lights when plugging the cable into the switch ports. What am I missing? 

    Are you definitely using the correct COM Port number? On Windows7 Right Click My Computer > Manage Then select Device Manager and expanPorts (COM & LPT)d  in my case is shows Prolific USB-to-Serial Comm Port (COM5). 
    Once you have the right COM Port number just use the default settings in Putty. You may find the COM Port is locked up which will require a reboot.

  • Warning message about Rx power high on Catalyst 4500E

    Hi,
    The following messages are logged in the irregular on Catalyst 4500E Supervisor Engine 7-E.
    Are these fiber links required the attenuators?
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.5 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.6 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.6 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.6 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.8 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.5 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    Thank you for your cooperation in advance.
    -------- Additional Logs Start --------
    Cat45E+Sup7E#show interfaces Te2/6 | inc media type
      Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-LR
    Cat45E+Sup7E#show interfaces Te3/6 | inc media type
      Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-LR
    Cat45E+Sup7E#show interfaces transceiver module 2
    Load for five secs: 5%/1%; one minute: 6%; five minutes: 6%
    Time source is NTP, 13:29:28.720 JST Tue Feb 19 2013
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Te2/1        35.6       3.26      -1.6      -0.2
    Te2/2        37.0       3.26      -1.7      -0.3
    Te2/3        35.1       3.27      -2.6      -2.2
    Te2/4        36.7       3.28      -2.5      -2.5
    Te2/5        35.6       3.25      -1.3      -0.9
    Te2/6        35.0       3.26      -1.7       0.6
    Te2/7        36.1       3.28      -2.4      -2.8
    Te2/8        35.1       3.28      -2.4      -3.0
    Te2/9        33.1       3.23      -2.4      -2.4
    Te2/10       32.2       3.32      -2.1      -3.0
    Te2/11       35.0       3.25      -2.5      -2.9
    Cat45E+Sup7E#show interfaces transceiver module 3
    Load for five secs: 6%/2%; one minute: 6%; five minutes: 6%
    Time source is NTP, 13:29:44.348 JST Tue Feb 19 2013
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Te3/1        36.2       3.26      -2.1       0.2
    Te3/2        35.6       3.26      -1.7      -0.6
    Te3/3        36.8       3.26      -2.4      -3.4
    Te3/4        36.8       3.28      -2.5      -2.6
    Te3/5        35.2       3.26      -1.3       0.0
    Te3/6        36.2       3.26      -1.1       0.9
    Te3/7        34.2       3.28      -2.4      -2.8
    Te3/8        34.0       3.29      -2.0      -3.1
    Te3/9        35.4       3.28      -2.5      -2.3
    Te3/10       32.5       3.24      -2.4      -4.2
    Te3/11       34.2       3.28      -2.4      -3.2
    Cat45E+Sup7E#show interfaces transceiver threshold-table
    Load for five secs: 7%/3%; one minute: 6%; five minutes: 6%
    Time source is NTP, 13:29:52.304 JST Tue Feb 19 2013
                  Optical Tx     Optical Rx    Temp     Laser Bias    Voltage
                                                        current
    10GE LR SFP+
    Min1            -12.20        -18.40        -5            N/A          3.00
    Min2             -8.20        -14.40        0             N/A          3.10
    Max2              0.50          0.50        70            N/A          3.50
    Max1              3.50          3.50        75            N/A          3.60
    -------- Additional Logs End --------

    Hello Marivin.
    I am configured new WS-C4500X-32 switches for distribution layer and server aggreation WS-C3650-48TQ-E with these model.
    I am geetting below error message. I read your document but i ham getting here low alaram, i have observed because of this i am loosing connectiy with my neibhor device and ehter channel is flapping.
    Kindly help me to fix this....
    *Jan 28 23:54:04.417: %SFF8472-5-THRESHOLD_VIOLATION: Te1/29: Rx power low alarm; Operating value: -16.4 dBm, Threshold value: -13.9 dBm.
    *Jan 28 23:54:07.317: %SFF8472-5-THRESHOLD_VIOLATION: Te1/31: Rx power low warning; Operating value: -10.5 dBm, Threshold value:  -9.9 dBm.
    *Jan 28 23:54:07.417: %SFF8472-5-THRESHOLD_VIOLATION: Te1/32: Rx power low warning; Operating value: -11.4 dBm, Threshold value:  -9.9 dBm.

  • T400 is rebooted unexpectedly

    Hello there,
    I have a problem with T400 that the laptop is rebooted unexpectedly when I try to logon Windows(at GINA). It's rarely happened. Once it's happened. It become I can not use my Windows account with a message like "You can not use this computer with this account, Please use other computer". It's in Japanese so It will not be properly translated. 
    After several hours, I can use the Windows account.
    Before shutdown PC manually, USB memory(ReadyBoost) was connected to the laptop. But, I'm not turned on readyboost on USB memory.Anyway I guess It might be a caused.
    My environment is below;
    T400
    BIOS:7UET93WW(ver. 3.23)
    Intel WiFi Link 5100 AGN(Driver ver.14.2.0.10)
    TPM 1.2
    Windows 7 Professional(Japanese) SP1 + latest hotfixes
    CSS 8.3
    Does someone know about this problem? Please help me.
    Sincerely,

    hey sbux0007,
    the T400 of yours, does it have one user account or 2 and is it being use in an office network? I normally stumble across >> "You can not use this computer with this account, Please use other computer" .. when it is a system that has two user accounts and when the computer is set to use with a network.
    since this rarely happens it is hard to pinpoint what is causing this. what i suggest would be that you keep an eye and make notes of what programs that you were using before the sudden reboot.
    WW Social Media
    Important Note: If you need help, post your question in the forum, and include your system type, model number and OS. Do not post your serial number.
    Did someone help you today? Press the star on the left to thank them with a Kudo!
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"!
    Follow @LenovoForums on Twitter!
    Have you checked out the Community Knowledgebase yet?!
    How to send a private message? --> Check out this article.

  • Connection of LC/APC fiber patch cords to Cisco Catalyst 6500 $ Cisco Access 3750 Switches

    I have an LC/APC fiber patch cord infrastructure and I want to connect it to Cisco Catalyst 6500 & Cisco Access 3750 Switches. what type of transceiver should be used?
    I read a note on Cisco website stating the following for Cisco SFP+ transceivers:
    Note: "Only connections with patch cords with PC or UPC connectors are supported. Patch cords with APC connectors are not supported. All cables and cable assemblies used must be compliant with the standards specified in the standards section"

    Thank you,  but my question is that I have a single mode fiber patch cord with LC/APC connector while cisco stating a note that only use LC/PC or LC/UPC type of connectors with SFP+ transceiver.  
    So what type of transceiver should I use to connect LC/APC patch cord to cisco switches?  Is there another type or SFP+ still can be used? 

  • Cisco Catalyst 2955 Causes Some Devices to "Die" During Boot

    I posted this question in the LAN section of the forums, but I realize this is probably the proper forum for my question.
    I have recently purchased a Cisco Catalyst model WS-2955C-12 switch. During POST (boot), the console reports that the switch undergoes what is known as a "FRONT-END LOOPBACK TEST". During this test the 14 port lights on the device light up amber for a moment, connectivity is lost, and after a second or two the lights go off and connectivity returns. We've found that the moment the lights go off at the end of this test, if we have a specific device (with a specific ethernet chip) directly connected to the switch the ethernet chip is adversely affected by this test - the device "goes dark" and is not capable of communicating with anything (including other switches, routers, etc...) until it is power-cycled. What exactly does this FRONT-END LOOPBACK TEST do (I know it's for validating the ports for hardware defects), and what does it send across the wire that could be causing my ethernet chip onboard the device to go bonkers?
    Thanks!
    -Danny

    The ethernet chip on the device (the device is a National Instruments product) is an STMicro STE10/100E, and I'm fairly confident I now know what's happening but I don't know why.
    When my ethernet chip is in Autonegotiate mode, the "FRONT-END LOOPBACK TEST" performed by the catalyst does something where, at the conclusion of the test, the ethernet chip goes into an autonegotiation state and never comes back out of it. I'm thinking the "FRONT-END LOOPBACK TEST" is sending something across the wire that's confusing this specific ethernet chip; I've tried 3 Intel parts and also a Broadcom part and they rode it out in autonegotiation mode just fine. If I put the STE chip into a manually-configured mode the "FRONT-END LOOPBACK TEST" doesn't cause it to "go dark".
    So, my question is really what does the FRONT-END LOOPBACK TEST do? Does it perform a remote loopback test (the STE10/100E doesn't support loopback tests)?
    -Danny

  • Ask the Expert: Layer 2 Security on Cisco Catalyst Platforms

    With Wilson Bonilla
    Welcome to the Cisco Support Community Ask the Expert conversation.  This  is an opportunity to learn and ask questions about about issues in designing, planning, and implementing Layer 2 security in your LAN network with expert Wilson Bonilla. 
    Wilson will cover topics that network engineers face daily such as Spanning Tree Protocol security, private VLANs, IP source guard, protected ports, dynamic ARP inspection, virtual LAN access-control lists (VLAN ACLs), and Dynamic Host Configuration Protocol (DHCP) snooping over Cisco Catalyst platforms.  With the fast growth of networks, Layer 2 security is even more critical in the LAN to help your network become more reliable, efficient, and secure. Wilson will answer your questions about LAN networks with Cisco Catalyst switches.  
    Wilson Bonilla is a technical networking trainer at the Learning and Development Department for Cisco Technical Assistance Center located in Costa Rica. Before joining the Training Department, he worked for the Cisco TAC as a customer support engineer focused on LAN Switching for more than two years. While working on LAN switching, Wilson also had roles such as technical leader and trainer, adding to his area of expertise in Cisco Catalyst Layer 2 switching. He has CCNP routing and switching certification and is currently studying to achieve his CCNA certification in data center.
    Remember to use the rating system to let Wilson know if you've received an adequate response. 
    Because of the volume expected during this event, Wilson might not be able to answer every question. Remember that you can continue the conversation in the Network Infrastructure community, subcommunity, LAN, Switching and Routing, shortly after the event. This event lasts through November, 2013. Visit this forum often to view responses to your questions and those of other Cisco Support Community members.

    Hello NetNavi.
    Check the post above about MacSec for more information and let me know if you need further clarification, if so I will do my best,
    In regards to best practices there is a Cisco document; it describes deployments and best practices in every scenario; Supplicants, authenticator, authentication services and other configurations. Please check it out:
    http://www.cisco.com/en/US/prod/collateral/iosswrel/ps6537/ps6586/ps6638/deploy_guide_c17-663760.html
    In regards to Private VLANS:
    What is a Private Vlan?
    A private Vlan is a way to isolate hosts within the same Vlan or broadcast domain. So even when you might have devices sharing the same broadcast domain they can be isolated, this isolated is configured based on sub-domains also most often called primary and secondary Vlans.
    What is a primary Vlan?
    The primary Vlan is representation of the private Vlan, a primary Vlan has one or more secondary Vlans, a switch uses the primary Vlan to present traffic from the secondary Vlans to its neighboring devices.
    What is a secondary Vlan?
    A secondary Vlan is a sub-domain of the primary Vlan. We could say that the secondary Vlans belongs to the primary. The must be associated to a primary Vlan. There are two types of secondary vlans: Isolated and Community secondary Vlans.
    What does it happen to host within a secondary isolated Vlan?
    Host within the isolated vlan; can’t communicate to neither other host in the same isoalted vlan nor host in a community vlan.
    What does it happen to host within the secondary community Vlan?
    Host within the community Vlan can communicate with other host assigned to the same community vlan, but they can’t talk to host in other community vlans.
    What are the benefits of implementing private Vlans?
    Scalability: The most common scenario is a service provider. Imagine all customers of a service provider connected through DSL, cable modem… it’s very likely that all customers belong to the same broadcast domain, however if that’s the case why is it that I can’t use my neighbor’s printer, or maybe why is it that I can’t access the files he has store in his computer, (security) we are in the same broadcast shouldn’t I be able to at least ping his ip address?. Well that’s because the ISP must guarantee some type of security for their customers, and because put every single customer that they have in a single Vlan is not scalable they use private Vlans.
    Examples:
    ISP use private vlans to protect from security bridges, Private vlans and isolated Vlans are used to protect personal information for example from one customer to another.
    DMZ; Many implementations utilizes private vlans in a DMZ to limt or minimize that risk of a compromised server.
    I would like to share this documentation with you for further information and configuration guidelines
    http://www.cisco.com/en/US/tech/tk389/tk814/technologies_configuration_example09186a008017acad.shtml#hw
    This document explains what Cisco Catalyst switches support Private Vlans. 
    http://www.cisco.com/en/US/products/hw/switches/ps708/products_tech_note09186a0080094830.shtml
    Let me know if you have further questions.
    Regards
    Wilson B.

  • Cisco Catalyst 6500 version 12.2(33)SXI13 configured as DHCP server for a VLAN responds to Windows 7 client with status code NOA

    Can anyone help figure out why the Catalyst 6509 is not able to assign an IPv6 address? Thank you.
    Cisco Catalyst 6500 version 12.2(33)SXI13 configured as DHCP server for a VLAN responds to Windows 7 client with status code NOADDRS-AVAIL(2). My configuration on the 6500 for the DHCPv6 server is:
    ipv6 dhcp database disk0://DHCPV6-DB
    ipv6 dhcp pool VLAN206IPV6
     prefix-delegation pool VLAN206IPV6-POOL
     dns-server 2620:B700:0:1001::53
     domain-name global.bio.com
    ipv6 local pool VLAN206IPV6-POOL 2620:B700:0:12C7::/65 65
    interface Vlan206
     description *** IPv6 Subnet ***  
     ip address 10.2.104.2 255.255.255.0
     ipv6 address 2620:B700:0:12C7::2/64
     ipv6 nd prefix 2620:B700:0:12C7::/64 14400 14400 no-autoconfig
     ipv6 nd managed-config-flag
     ipv6 dhcp server VLAN206IPV6
     standby version 2
     standby 0 ip 10.2.104.1
     standby 0 preempt
     standby 6 ipv6 2620:B700:0:12C7::1/64
     standby 6 preempt
    I'm getting a result from my debug as follows:
    Apr 10 16:28:02.873 PDT: %LINK-3-UPDOWN: Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:02.873 PDT: %LINK-SP-3-UPDOWN: Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:02.877 PDT: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Received SOLICIT from FE80::5D5E:7EBD:CDBF:2519 on Vlan206
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: detailed packet contents
    Apr 10 16:28:03.861 PDT:   src FE80::5D5E:7EBD:CDBF:2519 (Vlan206)
    Apr 10 16:28:03.861 PDT:   dst FF02::1:2
    Apr 10 16:28:03.861 PDT:   type SOLICIT(1), xid 8277025
    Apr 10 16:28:03.861 PDT:   option ELAPSED-TIME(8), len 2
    Apr 10 16:28:03.861 PDT:     elapsed-time 101
    Apr 10 16:28:03.861 PDT:   option CLIENTID(1), len 14
    Apr 10 16:28:03.861 PDT:     00010001195FD895F01FAF10689E
    Apr 10 16:28:03.861 PDT:   option IA-NA(3), len 12
    Apr 10 16:28:03.861 PDT:     IAID 0x0FF01FAF, T1 0, T2 0
    Apr 10 16:28:03.861 PDT:   option UNKNOWN(39), len 32
    Apr 10 16:28:03.861 PDT:   option VENDOR-CLASS(16), len 14
    Apr 10 16:28:03.861 PDT:   option ORO(6), len 8
    Apr 10 16:28:03.861 PDT:     DOMAIN-LIST,DNS-SERVERS,VENDOR-OPTS,UNKNOWN
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Option IA-NA(3) is not supported yet
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Sending ADVERTISE to FE80::5D5E:7EBD:CDBF:2519 on Vlan206
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: detailed packet contents
    Apr 10 16:28:03.861 PDT:   src FE80::21D:E6FF:FEE4:4400
    Apr 10 16:28:03.861 PDT:   dst FE80::5D5E:7EBD:CDBF:2519 (Vlan206)
    Apr 10 16:28:03.861 PDT:   type ADVERTISE(2), xid 8277025
    Apr 10 16:28:03.861 PDT:   option SERVERID(2), len 10
    Apr 10 16:28:03.865 PDT:     00030001001DE6E44400
    Apr 10 16:28:03.865 PDT:   option CLIENTID(1), len 14
    Apr 10 16:28:03.865 PDT:     00010001195FD895F01FAF10689E
    Apr 10 16:28:03.865 PDT:   option STATUS-CODE(13), len 15
    Apr 10 16:28:03.865 PDT:     status code NOADDRS-AVAIL(2)
    Apr 10 16:28:03.865 PDT:     status message: NOADDRS-AVAIL

    Hello,
    maybe hitting the following bug.
    Pv6 Address Assignment Support for IPv6 DHCP Server
    CSCse81385
    Hope this helps

  • Alternative switch to Cisco Catalyst 3750v2-24FS and 3750-24FS

    I`m looking for an alternative to these two switches:                 
    1.  WS-C3750V2-24FS-S  Cisco Catalyst 3750V2-24FS Switch with 24 100FX SFP + 2 Gigabit Ethernet SFP Ports
    2. Cisco Catalyst 3750-24FS (WS-C3750-24FS-S 100BASE-FX)
    They are now EOL and not available.
    I have a campus style network and need to be able to connect multiple 100FX fibre switches back to a central switch. The 1st unit uses 100FX SFP modules and the second has in-built 100FX ports. I`m struggling to find anything from Cisco that will give me multiple (i.e 12+) 100FX ports.
    Could anyone please point me in the right direction?
    Many thanks,
    Paul

    Hi Paul ,
    Replacement for both switch is WS-C3650-48TS-S.
    http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps5528/eos-eol-notice-c51-730227.html
    http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps5023/end_of_life_c51-687707.html
    Regards
    Don't forget to rate helpful posts
    Sent from Cisco Technical Support iPhone App

  • Debian Linux Bonding and Cisco Catalyst 3750 - best practise?

    Hello everybody,
    I would like to know what's best practice to do this:
    The two NICs of a Debian Linux server wants to be connected with two Switchports of a Cisco Catalyst 3750 switch(stack). My goal is to have load-balancing and failover.
    My /etc/network/interfaces looks like this:
    iface bond0 inet static
           address 192.168.0.30
           netmask 255.255.255.0
           network 192.168.0.0
           broadcast 192.168.0.255
           gateway 192.168.0.1
           dns-nameservers 192.168.0.10 192.168.0.20
           dns-search xyz.mycompany.com
           slaves eth0 eth1
           bond_mode ???
           bond_miimon 100
           bond_downdelay 200
           bond-updelay 200
    First question: What bond mode should I use?
    The switchports looks like this:
    interface GigabitEthernet3/0/4
     switchport access vlan 20
     switchport mode access
     spanning-tree portfast
    What changes are necessery here? Something like this?
    interface GigabitEthernet3/0/4
     switchport trunk encapsulation dot1q
     switchport mode trunk
     spanning-tree portfast
    Thanks a lot for suggestions, hints, etc.! :-)
    Greets
    Stephan

    Hi Michael,
    thanks a lot for your answer - and sorry for my late reply!
    I like to show you my solution - I hope that it is a solution. ;-)
    My config on the switch(stack):
    switch#show etherchannel summary
    Group  Port-channel  Protocol    Ports
    ------+-------------+-----------+-----------------------------------------------
    2      Po2(SU)         LACP      Gi3/0/3(P)  Gi4/0/3(P)
    switch#show running-config interface GigabitEthernet 3/0/3
    Building configuration...
    Current configuration : 172 bytes
    interface GigabitEthernet3/0/3
     description myserver, eth0
     switchport access vlan 20
     switchport mode access
     channel-group 2 mode active
     spanning-tree portfast
    end
    lansw01#show running-config interface GigabitEthernet 4/0/3
    Building configuration...
    Current configuration : 172 bytes
    interface GigabitEthernet4/0/3
     description myserver, eth1
     switchport access vlan 20
     switchport mode access
     channel-group 2 mode active
     spanning-tree portfast
    end
    switch#show running-config interface port-channel 2
    Building configuration...
    Current configuration : 82 bytes
    interface Port-channel2
     switchport access vlan 20
     switchport mode access
    end
    The /etc/network/interfaces of my Debian machine looks like this:
    auto lo
    iface lo inet loopback
    auto bond0
            iface bond0 inet static
            address 192.168.1.xxx
            netmask 255.255.255.0
            gateway 192.168.1.xxx
            dns-nameservers 192.168.1.xxx
            dns-search xxx.xxx.xxx
            bond-mode 4
            bond-miimon 100
            bond-downdelay 200
            bond-updelay 200
            bond-lacp-rate 1
            slaves eth0 eth1
    This setup seems to work well. But I'm wondering that there is nothing with "trunking" in my setup. Would you like to give me your opinion about this?
    Thanks a lot and many greets
    Stephan

  • 802.1x on Cisco Catalyst 2960

    I am trying to enable 802.1x on one of
    the switchports of the Cisco Catalyst
    2960:
    C2960#sh run | i radius
    aaa authentication login test group radius local
    aaa authentication dot1x default group radius
    radius-server host 10.250.97.26 auth-port 1812 acct-port 1813
    radius-server source-ports 1645-1646
    radius-server key 123456
    C2960#sh run | i dot
    aaa authentication dot1x default group radius
    dot1x system-auth-control
    dot1x guest-vlan supplicant
    dot1x critical eapol
    C2960#conf t
    Enter configuration commands, one per line. End with CNTL/Z.
    C2960(config)#int g0/14
    C2960(config-if)#dot1x ?
    % Unrecognized command
    C2960(config-if)#dot1x
    As you can see, I can not enable 802.1x
    at the interface level. The code is am running is 12.2.25SEE4:
    Switch Ports Model SW Version SW Image
    * 1 24 WS-C2960G-24TC-L 12.2(25)SEE4 C2960-LANBASEK9-M
    System image file is "flash:c2960-lanbasek9-mz.122-25.SEE4.bin"
    According to Cisco, this image supports
    802.1x. Why can't enable it at the
    interface level?
    Can someone help me out? Thanks.

    some additional info:
    C2960#sh dot1x all
    Sysauthcontrol Enabled
    Dot1x Protocol Version 2
    Critical Recovery Delay 100
    Critical EAPOL Enabled
    C2960#

  • Cisco catalyst 2960 booting garbage, help on restore IOS

    Dear All,
    This is my first time on terminal access of Cisco Catalyst 2960 (2960TC-L), normally would use the web configuration for most task.
    Now the switch has an issue with the web interface and when I try to access through terminal, I was greeted with garbage upon the booting of the switch, I searched for the terminal boot process and it wasn't what I was expected for my switch. I was a bit dumbfound now of how can I recover the firmware to its default stage, now that I cannot even boot through its terminal console.
    Any help is highly appreciated. Thank you for your time.

    Hi,
    I just verified with my colleague of whom have done quite a few bits before I took over his task.
    His reply was he actually did an IOS flash before, though I'm not sure how he did it, but according to him, it was actually a success and the web interface still works for few times before it become like this.
    As I tried another time to goes into root mode (or Admin mode??) for the switch, the steps as I performed below:
    1. Refer to cisco-2960-putting-setting.jpg for the settings. I press Open and it does display the console Window, no issue there.
    2. I hold the "mode" button on the switch and turn on the switch power, and after few seconds the screen display as such (refer to cisco-2960-putty-output2.jpg), the SYST L.E.D. did flash with following pattern: Green (blink ~15 times) then Orange-Green (repeat blink twice) then Green (stable light), for this I was expecting it to goes off after few seconds but it didn't, I wait about a minute before I let go the "mode" button.
    3. After I let go the "mode" button, it goes to the screen (refer cisco-2960-putty-output3.jpg), and the SYST still blinking, possibly infinitely... with the console output screen stays like that... and whatever I entered display weird/garbage characters instead, I can't do anything on it.
    Each tries display different weird characters, as the SYST still blinking infinitely.
    I'm unsure if I'm giving enough details for online troubleshooting, I'll try my best to give as per instructed.
    Thank you for your time.

Maybe you are looking for

  • Long load times and poor application performance

    We have packaged and deployed Adobe CC using SCCM within my school division. It pushed out fine, but now when we attempt to open Photoshop (or any other CC app) it has unusually long load times. 2-4 minutes. It seems to be hanging at the "Reading pre

  • Unable to select multiple messages in Mail.

    Hi, I can't select multiple messages in Mail app. After selecting few, all of them automatically deselects. This is really annoying. I'm on 6.1.2 iP5, and this is happening from the begining. Never happened before on my iP4. The other problem with ma

  • I always have the message : An older item already exist.

    When I copy file (that is already on the server) from imacSnow 10.6.7 to server tiger10.4.11, I always have the message : An older item already exist. Even if the file have the same or earlier date. The server and the Imac have the same time and zone

  • Media Manger won't reconnect Merged Clips

    I have a project that has tons of merged clips (Video synced to Audio .wav files). All is well within the project, but if I try to use Media Manager to copy media and duplicate it into a new project, it cannot reconnect the Merged Clips. Video comes

  • Pictures taken with Ipad are not clear

    Pictures are not clear using my Ipad. Please help