Cisco catalyst 4506-e boot error

Rommon signature verification PASSED for golden image
Rommon signature verification PASSED for primary image
FPGA signature verification PASSED for primary image
 * Welcome to Rom Monitor for   WS-X45-SUP7-E System.       *
 * Copyright (c) 2008-2011 by Cisco Systems, Inc.           *
 * All rights reserved.                                     *
 Primary Rom Monitor Version 15.0(1r)SG5
 CPU Rev: 2.2, Board Rev: 10, Board Type: 101, CPLD Moka Rev: 7.0x3718.0xb565
 Chassis: WS-C4506-E
Got Mac Address: c0:67:af:40:24:c2
 MAC Address  : c0-67-af-40-24-c2
 IP Address   : 14.18.2.234
 Netmask      : 255.255.255.0
 Gateway      : 14.18.2.21
 TftpServer   : Not set.
 Peer supervisor not detected or is not running IOS
 Supervisor uplinks and all linecards have been reset
 ***** The system will autoboot in 5 seconds *****
 Type control-C to prevent autobooting.
 ******** The system will autoboot now ********
 config-register = 0x2101
 Autobooting using the first file from bootflash.....
loading image
Checking digital signature
bootflash:/cat4500e-universal.SPA.03.05.02.E.152-1.E2.bin: Digitally Signed Release Software with key version A
Rommon reg: 0x00004F80
Reset2Reg: 0x00000F00
Image load status: 0x00000000
Snowtrooper 155 controller 0x044DDBD2..0x04688FA7 Size:0x0041DCD4 Program Done!
[   57.324367] pci 0000:00:00.0: ignoring class b20 (doesn't match header type 01)
Starting System Services
Calculating module dependencies ...
Loading rtc-ds1307
RTNETLINK answers: Invalid argument
No Mountpoints DefinedNov 13 09:35:24 %IOSXE-3-PLATFORM: process sshd[4211]: error: Bind to port 22 on :: failed: Address already in use.
diagsk10-post version 5.1.4.0
prod: WS-X45-SUP7-E part: 73-14393-02 serial: CAT1837L75P
Power-on-self-test for Module 1: WS-X45-SUP7-E
CPU Subsystem Tests ...
 seeprom: Pass
Traffic: L3 Loopback ...
 Test Results: Pass
Traffic: L2 Loopback ...
post timeout
A Critical job [post] exited abnormally! Reloading the supervisor
Killed by signal [TERM]
Loading virtuclock as vuclock
Loading gsbu64atomic as gdb64atomic
Loading isp1362_hcd_k10
/dev/fd/13: line 273: /sys/devices/system/edac/mc/edac_mc_log_ce: No such file or directory
Starting IOS Services
AIPC Module Loaded...
cat4k-watchdog[6250]: Watchdog daemon initialized on 2 CPU(s)
cat4k-watchdog[6250]: Watchdog daemon started.
Dumping all the logs to /root/reload.20141113..Please be patient
All logs dumped
sysmgr: <<%SYSMGR-2-SERVICE_CRASHED>> Service "System Manager (parser)" (PID 6820) hasn't caught signal 15 (no core).
/bin/kill: 8178: No such process
/bin/kill: 8179: No such process
/bin/kill: 8197: No such process
/bin/kill: 8198: No such process
/etc/rc6.d/S01reboot: line 198: umount_cisco_filesystems: command not found
Please stand by while rebooting the system...
[  266.041680] Restarting system.
Rommon signature verification PASSED for golden image
Rommon signature verification PASSED for primary image
FPGA signature verification PASSED for primary image
 * Welcome to Rom Monitor for   WS-X45-SUP7-E System.       *
 * Copyright (c) 2008-2011 by Cisco Systems, Inc.           *
 * All rights reserved.                                     *
 Primary Rom Monitor Version 15.0(1r)SG5
 CPU Rev: 2.2, Board Rev: 10, Board Type: 101, CPLD Moka Rev: 7.0x3718.0xb565
 Chassis: WS-C4506-E
Got Mac Address: c0:67:af:40:24:c2
 MAC Address  : c0-67-af-40-24-c2
 IP Address   : 14.18.2.234
 Netmask      : 255.255.255.0
 Gateway      : 14.18.2.21
 TftpServer   : Not set.
 Peer supervisor not detected or is not running IOS
 Supervisor uplinks and all linecards have been reset
 ***** The system will autoboot in 5 seconds *****
 Type control-C to prevent autobooting.
 ******** The system will autoboot now ********
 config-register = 0x2101
 Autobooting using the first file from bootflash.....
loading image
Version: cat4500e-universal.SPA.03.05.02.E.152-1.E2.bin
Any help PLZ

config-register = 0x2101
Autobooting using the first file from bootflash.....
You need to provide more information.  What are you trying to do?  How many IOS file(s) do you have in the bootflash? 
sysmgr: <<%SYSMGR-2-SERVICE_CRASHED>> Service "System Manager (parser)" (PID 6820) hasn't caught signal 15 (no core).
Break into the auto-boot process and post the output to the command "dir bootflash:".

Similar Messages

  • Monitoring Cisco Catalyst 4506

    Hello
    I am looking Cisco SNMP MIB or some Nagios plugin that allow to monitoring PoE status on Cisco Catalyst 4506 modules and check Led indicator status  simmilar I can do it by coomand "show enviroment "
    Module 2 Status Led Color : Green    PoE Led Color: Orange
    Module 3 Status Led Color : Green    PoE Led Color : Green
    Thank you very much

    Hi jon.marshall,
    Thanks for you reply. I'll explain how the traffic flows:
    1. Client boot up workstation
    2. After booting up, client obtain IP addressing through DHCP service from a remote DHCP server using gateway of VLAN210 (172.18.212.1)
    3. IP addressing issued to client (for e.g 172.18.212.128) and open web browser (HTTP) using a proxy (proxy.skynet.gov) with a DNS setting of skynet.gov.
    4. Next hop is a Juniper Enforcer (a.k.a firewall) with IP address 172.18.221.234 (Enforcer 1 - Master) and 172.18.221.235 (Enforcer 2 - Backup) which have a policy rule stating that the client range of 172.18.212.0 to 172.18.212.255 wanting to contact the proxy (proxy.skynet.gov), the next hop would be the Juniper UAC Host checker (with IP address of 172.18.223.254).
    Note: There are 2x physical Junpier Enforcer and only 1x Juniper Host Checker
    5. Juniper UAC Host Checker checks client workstation to ensure that minimum requirements are met before allowing client to go to internet
    6. Once clients pass the Juniper UAC Host Checker, traffic to the internet is then allowed.
    7. Clients surf the internet.
    8. End
    To answer your questions:
    i. The UAC is not on the same subnet however, all routing is done on the Cisco Catalyst 4506 and the UAC and VLAN are all on the 4506 too.
    ii. I'm not sure if the Juniper UAC is the one that makes all Http request of VLAN210 (172.18.212.0 to 172.18.212.255) or it will let the client make its on Http request after it passes the host checker.
    iii. Yes. I have 2x Cisco Catalyst 4506 and they are connected to each other through HSRP
    iv. The proxy (proxy.skynet.gov) is configured on the clients browser.
    Note: Is the DNS name of the proxy server, NOT the IP address of the proxy server.
    I hope the above provided information is sufficient for you reference to provide me the actual syntax for my requirement. Thanks.
    Cheers!!!

  • Cisco IPS4255 won't boot (error=Searching / for images to boot. No images found in / Error 15: File not found unable to boot an image)

    Hello,
    I have a Cisco IPS4255 that will not boot an image.  I'm seemingly successfully completing a TFTPDNLD each time, but it keeps rebooting with the cannot find image in \ error.
    Here is a detailed snap shot:
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin-top:0in;
    mso-para-margin-right:0in;
    mso-para-margin-bottom:10.0pt;
    mso-para-margin-left:0in;
    line-height:115%;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;
    mso-bidi-font-family:"Times New Roman";
    mso-bidi-theme-font:minor-bidi;}
    #1- I TFTP image to device which automatically starts the output below:
    ENABLING IO-APIC IRQs
    Setting 14 in the phys_id_present_map
    ...changing IO-APIC physical APIC ID to 14 ... ok.
    Setting 13 in the phys_id_present_map
    ...changing IO-APIC physical APIC ID to 13 ... ok.
    ..TIMER: vector=0x31 pin1=2 pin2=0
    testing the IO APIC.......................
    .................................... done.
    Using local APIC timer interrupts.
    calibrating APIC timer ...
    ..... CPU clock speed is 3000.1599 MHz.
    ..... host bus clock speed is 200.0105 MHz.
    cpu: 0, clocks: 2000105, slice: 1000052
    CPU0<T0:2000096,T1:1000032,D:12,S:1000052,C:2000105>
    Waiting on wait_init_idle (map = 0x0)
    All processors have done init_idle
    PCI: PCI BIOS revision 2.10 entry at 0xff648, last bus=4
    PCI: Using configuration type 1
    PCI: Probing PCI hardware
    PCI: Probing PCI hardware (bus 00)
    PCI: Ignoring BAR0-3 of IDE controller 00:1f.2
    Transparent bridge - Intel Corp. 82801BA/CA/DB/EB PCI Bridge
    PCI->APIC IRQ transform: (B0,I29,P0) -> 16
    PCI->APIC IRQ transform: (B0,I29,P1) -> 19
    PCI->APIC IRQ transform: (B0,I29,P3) -> 23
    PCI->APIC IRQ transform: (B0,I31,P0) -> 16
    PCI->APIC IRQ transform: (B0,I31,P1) -> 17
    PCI->APIC IRQ transform: (B0,I31,P1) -> 17
    PCI->APIC IRQ transform: (B2,I1,P0) -> 18
    PCI->APIC IRQ transform: (B3,I1,P0) -> 24
    PCI->APIC IRQ transform: (B3,I2,P0) -> 24
    PCI->APIC IRQ transform: (B3,I2,P1) -> 25
    PCI->APIC IRQ transform: (B3,I3,P0) -> 26
    PCI->APIC IRQ transform: (B3,I3,P1) -> 27
    PCI->APIC IRQ transform: (B4,I2,P0) -> 16
    PCI->APIC IRQ transform: (B4,I3,P0) -> 17
    PCI: Cannot allocate resource region 0 of device 00:00.0
    isapnp: Scanning for PnP cards...
    isapnp: No Plug & Play device found
    Linux NET4.0 for Linux 2.4
    Based upon Swansea University Computer Society NET3.039
    Initializing RT netlink socket
    Starting kswapd
    allocated 32 pages and 32 bhs reserved for the highmem bounces
    Journalled Block Device driver loaded
    keyboard: controller not found
    pty: 2048 Unix98 ptys configured
    Serial driver version 5.05c (2001-07-08) with MANY_PORTS MULTIPORT SHARE_IRQ SER
    IAL_PCI ISAPNP enabled
    ttyS00 at 0x03f8 (irq = 4) is a 16550A
    ttyS01 at 0x02f8 (irq = 3) is a 16550A
    Real Time Clock Driver v1.10f
    RAMDISK driver initialized: 16 RAM disks of 30720K size 1024 blocksize
    loop: loaded (max 8 devices)
    lpc: version 0.1 (Mar  4 2005)
    Uniform Multi-Platform E-IDE driver Revision: 7.00beta4-2.4
    ide: Assuming 33MHz system bus speed for PIO modes; override with idebus=xx
    hda: TOQHIBA THLCD512MBA, CFA DISK drive
    hdb: QalDisi QDAF@-510, ATA DISK drive
    ide0 at 0x1f0-0x1f7,0x3f6 on irq 14
    hda: attached ide-disk driver.
    hda: task_no_data_intr: status=0x51 { DriveReady SeekComplete Error }
    hda: task_no_data_intr: error=0x04 { DriveStatusError }
    hda: 484848 sectors (248 MB) w/2KiB Cache, CHS=481/16/63
    hdb: attached ide-disk driver.
    hdb: task_no_data_intr: status=0x51 { DriveReady SeekComplete Error }
    hdb: task_no_data_intr: error=0x04 { DriveStatusError }
    hdb: 484848 sectors (248 MB) w/1KiB Cache, CHS=481/16/63
    Partition check:
    hda: hda1 hda2 hda3 hda4
    hdb: hdb1 hdb2 hdb3 hdb4
    ide: late registration of driver.
    SCSI subsystem driver Revision: 1.00
    i2c-core.o: i2c core module version 2.8.7 (20040611)
    i2c-dev.o: i2c /dev entries driver module version 2.8.7 (20040611)
    i2c-proc.o version 2.8.7 (20040611)
    i2c-i801 version 2.8.7 (20040611)
    NET4: Linux TCP/IP 1.0 for NET4.0
    IP Protocols: ICMP, UDP, TCP, IGMP
    IP: routing cache hash table of 32768 buckets, 256Kbytes
    TCP: Hash tables configured (established 262144 bind 65536)
    Linux IP multicast router 0.06 plus PIM-SM
    NET4: Unix domain sockets 1.0/SMP for Linux NET4.0.
    RAMDISK: Compressed image found at block 0
    Freeing initrd memory: 26522k freed
    VFS: Mounted root (ext2 filesystem) readonly.
    Freeing unused kernel memory: 136k freed
    init started:  EXT2-fs warning: checktime reached, running e2fsck is recommended
    BusyBox v1.00-rc1 (2005.03.04-09:39+0000) multi-call binary
    init started:  BusyBox v1.00-rc1 (2005.03.04-09:39+0000) multi-call binary
    Starting pid 10, console /dev/ttyS0: '/etc/init.d/rcS'
    Recovery version 1.13
    Started on Sun Mar  7 05:17:41 UTC 2010
    Full system recovery
    A
    Please press Enter to activate this console.
    tarting pid 86, console /dev/ttyS0: '/bin/sh'
    BusyBox v1.00-rc1 (2005.03.04-09:39+0000) Built-in shell (ash)
    Enter 'help' for a list of built-in commands.
    #2- I’m not a unix/linux person so I don’t have the knowledge to fix the “hdx” errors above, so after reboot it goes to “rommon”
    Booting system, please wait...
    CISCO SYSTEMS
    Embedded BIOS Version 1.0(10)0 03/25/05 22:42:05.25
    Low Memory: 631 KB
    High Memory: 3968 MB
    PCI Device Table.
    Bus Dev Func VendID DevID Class              Irq
    00  00  00   8086   2578  Host Bridge
    00  01  00   8086   2579  PCI-to-PCI Bridge
    00  03  00   8086   257B  PCI-to-PCI Bridge
    00  1C  00   8086   25AE  PCI-to-PCI Bridge
    00  1D  00   8086   25A9  Serial Bus         11
    00  1D  01   8086   25AA  Serial Bus         10
    00  1D  04   8086   25AB  System
    00  1D  05   8086   25AC  IRQ Controller
    00  1D  07   8086   25AD  Serial Bus         9
    00  1E  00   8086   244E  PCI-to-PCI Bridge
    00  1F  00   8086   25A1  ISA Bridge
    00  1F  02   8086   25A3  IDE Controller     11
    00  1F  03   8086   25A4  Serial Bus         5
    00  1F  05   8086   25A6  Audio              5
    02  01  00   8086   1075  Ethernet           11
    03  01  00   177D   0003  Encrypt/Decrypt    9
    03  02  00   8086   1079  Ethernet           9
    03  02  01   8086   1079  Ethernet           9
    03  03  00   8086   1079  Ethernet           9
    03  03  01   8086   1079  Ethernet           9
    04  02  00   8086   1209  Ethernet           11
    04  03  00   8086   1209  Ethernet           5
    Evaluating BIOS Options ...
    Launch BIOS Extension to setup ROMMON
    Cisco Systems ROMMON Version (1.0(10)0) #0: Fri Mar 25 23:02:10 PST 2005
    Platform IPS-4255-K9
    Management0/0
    Link is UP
    MAC Address: 000f.f775.7e24
    Use ? for help.
    rommon #0>
    #3- If the TFTP is rerun the entire cycle starts again.

    The IPS 4255 sensor appliance has only a single 512 MB internal CompactFlash module for storage by-default, so this part of the output you posted is interesting:
    hda: TOQHIBA THLCD512MBA, CFA DISK drive
    hdb: QalDisi QDAF@-510, ATA DISK drive
    ide0 at 0x1f0-0x1f7,0x3f6 on irq 14
    hda: attached ide-disk driver.
    hda: task_no_data_intr: status=0x51 { DriveReady SeekComplete Error }
    hda: task_no_data_intr: error=0x04 { DriveStatusError }
    hda: 484848 sectors (248 MB) w/2KiB Cache, CHS=481/16/63
    hdb: attached ide-disk driver.
    hdb: task_no_data_intr: status=0x51 { DriveReady SeekComplete Error }
    hdb: task_no_data_intr: error=0x04 { DriveStatusError }
    hdb: 484848 sectors (248 MB) w/1KiB Cache, CHS=481/16/63
    As it appears that two (2) 256 MB ("248 MB") storage devices are being detected (despite the model of the first even containing "512MB" in its name).
    I'd recommend double-checking that there is nothing installed in the "External compact flash device" slot located on the back of the appliance. See here for reference: http://www.cisco.com/en/US/docs/security/ips/7.0/installation/guide/hw_installing_4240_4255.html#wp2726
    If there is a CompactFlash module installed there, eject and remove it, then power-cycle the appliance and attempt the re-image ("recovery") process once more. If the boot output still contains the same errors for hda and hdb, then it is probably a failing/failed CompactFlash module, so an RMA will likely be necessary to resolve.

  • Catalyst 4506 and Modules in Pwr Over state

    Hello,
    First of all, my excuses for my bad english.
    I am experiencing a problem with a Cisco Catalyst 4506.
    The switch is filled with 48 port PoE blades (WS-X4248-RJ45V).
    The error we receive is:
    Sept 5 15:40:12: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sept 5 16:37:04: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sept 5 16:37:04: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    According to the Cisco website:
    Explanation
    This message indicates that the measured PoE is at least 50 w higher than the configured value. The switch has either misconfigured PoE or an unauthorized powered device that is connected to the switch and is drawing a lot of PoE.
    Out put for the commands sh power details and sh module all are attached.
    The switch has no PoE devices on the specific blade.
    Atleast not that we know.
    Does any one know some other solution?
    Thanks in advance.
    Martijn Groenleer

    Well, blade six went offline on the first row of the log i posted earlier.
    The problem is, the log doesn't mention in the message which module went offline.
    About the 'efficiency' i noticed this also, what could be causing this? Power supplies are already replaced. PoE is on default settings currently.
    A full log related to these power over warnings:
    Aug 30 23:27:00: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Aug 30 23:39:34: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Aug 30 23:39:34: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 3 08:45:46: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 3 08:57:49: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 3 08:57:49: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 01:53:04: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 02:23:16: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 02:23:16: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 16:10:58: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 17:20:23: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 17:20:23: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 17:58:14: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 18:09:37: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 18:09:37: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 19:13:15: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 19:56:11: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 19:56:11: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 5 09:02:16: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 5 09:10:46: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 5 09:10:46: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 5 15:40:12: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 5 16:37:04: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 5 16:37:04: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online

  • Cisco Catalyst 2955 Causes Some Devices to "Die" During Boot

    I posted this question in the LAN section of the forums, but I realize this is probably the proper forum for my question.
    I have recently purchased a Cisco Catalyst model WS-2955C-12 switch. During POST (boot), the console reports that the switch undergoes what is known as a "FRONT-END LOOPBACK TEST". During this test the 14 port lights on the device light up amber for a moment, connectivity is lost, and after a second or two the lights go off and connectivity returns. We've found that the moment the lights go off at the end of this test, if we have a specific device (with a specific ethernet chip) directly connected to the switch the ethernet chip is adversely affected by this test - the device "goes dark" and is not capable of communicating with anything (including other switches, routers, etc...) until it is power-cycled. What exactly does this FRONT-END LOOPBACK TEST do (I know it's for validating the ports for hardware defects), and what does it send across the wire that could be causing my ethernet chip onboard the device to go bonkers?
    Thanks!
    -Danny

    The ethernet chip on the device (the device is a National Instruments product) is an STMicro STE10/100E, and I'm fairly confident I now know what's happening but I don't know why.
    When my ethernet chip is in Autonegotiate mode, the "FRONT-END LOOPBACK TEST" performed by the catalyst does something where, at the conclusion of the test, the ethernet chip goes into an autonegotiation state and never comes back out of it. I'm thinking the "FRONT-END LOOPBACK TEST" is sending something across the wire that's confusing this specific ethernet chip; I've tried 3 Intel parts and also a Broadcom part and they rode it out in autonegotiation mode just fine. If I put the STE chip into a manually-configured mode the "FRONT-END LOOPBACK TEST" doesn't cause it to "go dark".
    So, my question is really what does the FRONT-END LOOPBACK TEST do? Does it perform a remote loopback test (the STE10/100E doesn't support loopback tests)?
    -Danny

  • Cisco catalyst 2960 booting garbage, help on restore IOS

    Dear All,
    This is my first time on terminal access of Cisco Catalyst 2960 (2960TC-L), normally would use the web configuration for most task.
    Now the switch has an issue with the web interface and when I try to access through terminal, I was greeted with garbage upon the booting of the switch, I searched for the terminal boot process and it wasn't what I was expected for my switch. I was a bit dumbfound now of how can I recover the firmware to its default stage, now that I cannot even boot through its terminal console.
    Any help is highly appreciated. Thank you for your time.

    Hi,
    I just verified with my colleague of whom have done quite a few bits before I took over his task.
    His reply was he actually did an IOS flash before, though I'm not sure how he did it, but according to him, it was actually a success and the web interface still works for few times before it become like this.
    As I tried another time to goes into root mode (or Admin mode??) for the switch, the steps as I performed below:
    1. Refer to cisco-2960-putting-setting.jpg for the settings. I press Open and it does display the console Window, no issue there.
    2. I hold the "mode" button on the switch and turn on the switch power, and after few seconds the screen display as such (refer to cisco-2960-putty-output2.jpg), the SYST L.E.D. did flash with following pattern: Green (blink ~15 times) then Orange-Green (repeat blink twice) then Green (stable light), for this I was expecting it to goes off after few seconds but it didn't, I wait about a minute before I let go the "mode" button.
    3. After I let go the "mode" button, it goes to the screen (refer cisco-2960-putty-output3.jpg), and the SYST still blinking, possibly infinitely... with the console output screen stays like that... and whatever I entered display weird/garbage characters instead, I can't do anything on it.
    Each tries display different weird characters, as the SYST still blinking infinitely.
    I'm unsure if I'm giving enough details for online troubleshooting, I'll try my best to give as per instructed.
    Thank you for your time.

  • Error in switch ports POE model, "Cisco Catalyst 2960S-24PS-L Switch"

    I have problem with the poe switch Cisco Catalyst 2960S-24PS-L posts does not respond, and me the following error resporta was t
    %PLATFORM_ENV-3-ILP_PORT_POST_ERR: %s can’t be brought up because it failed POST
    in Inline Power test.
    he source of that error and what are the possible causes

    Hey Dustin,
    Device needs to be RMA'ed. The inline power supply has failed.
    HTH.
    Regards,
    RS.

  • Cisco Catalyst WS-C3560-48TS and DLINK 3120 interface errors

    Hello, 
    We are getting  a lot of FCS-Err in one FC- GIgabit trunking  interface between  Cisco Catalyst WS-C3560-48TS running IOS   Version 12.2(25)SEE3 and DLINK 3120 Firmware 4.00.015.
    Our config in the cisco is the following:
    interface GigabitEthernet0/1
     description SWITCH-Dlink01
     switchport trunk encapsulation dot1q
     switchport mode trunk
     macro description cisco-switch
     spanning-tree link-type point-to-point
    We have tried without "macro description cisco-switch" and "spanning-tree link-type point-to-point" too and the problem persist.
    If we run "sh interfaces counters errors"
    Port        Align-Err    FCS-Err   Xmit-Err    Rcv-Err UnderSize
    Gi0/1               0      11423          0      11423  12516029
    The errors counters in the DLINK are growing very fast too.
    Usually these errors are related with hardware or cable problems, we have changed the cable, the SFP and the port, but the problem is still there.
    We have activated the debug for the interface and syslog, but we aren't getting any error.
    Do you have any idea about this issue or how to troubleshoot it?

    Hi,
    Try to hard set the ports on both sides to Gig/full duplex and test again.
    HTH

  • Wccp catalyst 4506

    Hi..
    I have been trying to configure wccp on catalyst 4506 switches running VSS but unable to complete setup config. I need your help in configuring wccp.
    i want ports www/https to be redirected to proxy server. And want to enable wccp on vlan interface. Pls help me in configuring it. Also any config example will be really helpful and appreciated.

    Your switch is crashing due to multibit ECC errors. Upgrade your ROMMON to 12.1(20r)EW2. You might want to also upgrade IOS to 12.2(18)EW4
    http://www.cisco.com/cgi-bin/bugtool/onebug.pl?bugid=CSCed25996
    You can download it from
    http://www.cisco.com/kobayashi/sw-center/lan/cat4000.shtml

  • Password reset on a Cisco Catalyst 3550 series

    We have a Cisco Catalyst 3550 series, and we don't have the password to gain access to the switch through a web browser. My question is if I reset the password using Hyper-terminal, does changing the password affect any vlan or fiber optic settings that I should know about. Or does resetting the password changes our switch to factory settings? 

    Hi,
    The password recovery procedure for your switch is described in this document:
    http://www.cisco.com/c/en/us/support/docs/switches/catalyst-2950-series-switches/12040-pswdrec-2900xl.html
    If you follow the instructions in the document exactly, you will retain the original configuration - you just rename the configuration file so that it is not loaded when the switch boots up. However, you will still be able to display it after the switch boots up using the more flash:config.old . Eventually, you can even load it into running-config using copy flash:config.old running-config command. At that point, the old passwords will be brought back but because you already are in the privileged EXEC mode, you can change them and save the updated configuration.
    VLANs should not be affected as long as you do not delete the vlan.dat file located in FLASH. Fiber optic ports should not be affected as long as you are using original Cisco GBICs. If you're using 3rd party GBICs, it may be necessary to enter the service unsupported-transceiver hidden command in the global configuration mode before they get recognized.
    Good luck!
    Best regards,
    Peter

  • Cisco catalyst 2690 switch vlanTable

    Hi,
    I have a cisco catalyst 2690 switch.
    I want monitoring IP, MAC, and Port Address.
    I use this docu: http://docstore.mik.ua/orelly/perl/sysadmin/ch10_03.htm
    This works great:
    htvtef7-nagios:/ # snmptranslate -On BRIDGE-MIB:dot1dTpFdbTable
    .1.3.6.1.2.1.17.4.3
    snmpwalk -c tef7snmp@761 -v 2c 10.76.1.7 .1.3.6.1.2.1.17.4.3
    htvtef7-nagios:/ # snmptranslate -On BRIDGE-MIB:dot1dBasePortTable
    .1.3.6.1.2.1.17.1.4
    snmpwalk -c tef7snmp@761 -v 2c 10.76.1.7 .1.3.6.1.2.1.17.1.4
    htvtef7-nagios:/ # snmptranslate -On CISCO-STACK-MIB:vlanTable
    .1.3.6.1.4.1.9.5.1.9.2
    But I get a error:
    htvtef7-nagios:/ # snmpwalk -c tef7snmp -v 2c 10.76.1.7 .1.3.6.1.4.1.9.5.1.9.2
    SNMPv2-SMI::enterprises.9.5.1.9.2 = No Such Object available on this agent at this OID
    Switch config:
    snmp-server community testament RO
    snmp-server community tef7snmp RO
    snmp-server location XYZ
    snmp-server contact MR.XYZ
    snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart
    snmp-server enable traps tty
    snmp-server enable traps cluster
    snmp-server enable traps entity
    snmp-server enable traps cpu threshold
    snmp-server enable traps vtp
    snmp-server enable traps vlancreate
    snmp-server enable traps vlandelete
    snmp-server enable traps flash insertion removal
    snmp-server enable traps port-security
    snmp-server enable traps envmon
    snmp-server enable traps mac-notification
    snmp-server enable traps copy-config
    snmp-server enable traps config
    snmp-server enable traps bridge newroot topologychange
    snmp-server enable traps stpx inconsistency root-inconsistency loop-inconsistency
    snmp-server enable traps syslog
    snmp-server enable traps vlan-membership
    snmp-server host XXX.XXX.XXX.XXX public
    snmp-server host YYY.YYY.YYY.YYY  tef7snmp
    What did I do wrong?
    THX!

    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Normál táblázat";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin:0cm;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:10.0pt;
    font-family:"Times New Roman";
    mso-ansi-language:#0400;
    mso-fareast-language:#0400;
    mso-bidi-language:#0400;}
    Thx for the replay!
    I use on the switch c2960-lanbasek9-mz.122-25.SEE3.bin (IOS),
    the Cisco Feature Navigator say, this IOS support the CISCO-STACK-MIB:
    http://tools.cisco.com/ITDIT/MIBS/MainServlet?ReleaseSel=0&PlatformSel=0&fsSel=0&IMAGE_NAME=c2960-lanbasek9-mz.122-25.SEE3.bin&SUBMIT2=Submit&IMAGE_ID=816103
    In show snmp mib I could not find the vlanTable. See the attachment.
    I du not understand!

  • Cisco WS-4506-E Switch with Supervisor II (EOL, EOS)

    Hello,
    I have a Distribution/Access Switch Cisco WS-4506-E Switch with Supervisor II (EOL, EOS). when are the exact EOL/EOS dates and can only upgrade the supervisor engine to Supervisor 8?
    Thanks

    EoS/EoL:  Cisco Catalyst 4003 Chassis, Supervisor Engine I & III

  • Cisco Catalyst 3750V2-24FS-S can't accept GLC-FE-100FX SFP Transceiver

    I have Cisco Catalyst 3750V2-24FS-S with OS version 12.2(55)EY, the problem it's can't accept GLC-FE-100FX SFP module, it's show
    unsupported SFP error but it' work fine with GLC-FE-100LX.
    Cisco 100-Megabit Ethernet SFP Modules Compatibility Matrix in bellow link show WS-C3750V2-24FS-S work with Transceiver Models :
    GLC-GE-100FX
    GLC-FE-100FX
    GLC-FE-100LX
    GLC-FE-100BX-D
    GLC-FE-100BX-U
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL632702.pdf
    Any help is appreciated

    Hi,
    I'm connectiong to 100FX SFP ports ( 1 to 24), showing error message:
    “ %PHY-4-SFP-NOT-SUPPORTED: The SFP in Fa1/0/1 in not supported”
    Thanks

  • Upgrade of Cisco Catalyst 3750G 24T

    Hi, 
    I want to upgarde a Cisco Catalyst 3750G 24T because I can't see the web interface.
    I checked the documentation and see a lot of videos on the net.
    I downloaded the new firmware c3750-ipbasek9-mz.122-55.SE9.bin
    I downloaded a tftp software and putted my ip adress on it.
    I connected the Cisco by console and launched Putty by serial.
    I sended en for grant my right access.
    I sended my password
    and tapped :
    copy tftp: flash:
    it asks TFTP Ip, i gave it
    10.0.0.45
    file name
    i gave it 
    c3750-ipbasek9-mz.122-55.SE9.bin
    and after It sended me when it must put it and i sended the same name.
    c3750-ipbasek9-mz.122-55.SE9.bin
    And then It works few seconds and the cisco says error ... time out.
    I've tested with W8, W7 and a lot of tftp server. I disabled my firewall.
    The password is the default password. It is a problem ?
    Can you help me ?
    Thanks
    Nicolas

    Copying only the BIN files into the appliance will NOT help.  You still won't be able to use the web interface.  
    You need to download the full IOS, the filename ends with TAR.   To unpack the file into your appliance you use the command "archive download-sw tftp://<TFTP IP address>/filename.tar".

  • Trunk between Cisco Catalyst and DLINK DES-7210

    Hi,
    i would like to configure a Trunk with all VLANs between a Cisco Catalyst 3650 an a DLINK DES-7210.
    On the DLINK is the def. GW via VRRP defined.
    Now i get the following Error:
    %ARP-4-DUPADDR: Duplicate address 172.28.72.1 on interface VLAN 72 port TenGigabitEthernet 5/3, sourced by 24e9.b397.2c34
    This is the Uplink Interface on the Cisco Switch.
    What can cause this?
    here`s the config of the Cisco Port:
    interface TenGigabitEthernet1/1/4
    switchport mode trunk
    switchport nonegotiate
    load-interval 30
    udld port disable
    spanning-tree bpdufilter enable
    end
    sh inter trunk
    Port        Mode             Encapsulation  Status        Native vlan
    Te1/1/4     on               802.1q         trunking      1
    Port        Vlans allowed on trunk
    Te1/1/4     1-4094
    Port        Vlans allowed and active in management domain
    Te1/1/4     1,8,12,16,20-24,32,36,40,44,48,56,64,68,72,76,80,88,92,96,201,211,239-242,244-249,260,264,268,1212,1216,1220,1224,1228,1232,1234,1236,1240,1244,1248,1252,1256,1260,1264,1268
    Port        Vlans in spanning tree forwarding state and not pruned
    Te1/1/4     1,8,12,16,20-24,32,36,40,44,48,56,64,68,72,76,80,88,92,96,201,211,239-242,244-249,260,264,268,1212,1216,1220,1224,1228,1232,1234,1236,1240,1244,1248,1252,1256,1260,1264,1268
    and here is the DLINK Switch:
    interface TenGigabitEthernet 5/3
    switchport mode trunk
    description test
    sh int ten 5/3 trunk
    Interface                Mode   Native VLAN VLAN lists
    TenGigabitEthernet 5/3   On     1           ALL

    Do you have the same IP configured on both switches ?
    Jon