Cisco DMP 4310 with standard power injector.

Hi,
I am trying to use a Cisco DMP 4310 with a standard power injector (PRJ3) but it seems that the DMP doesn't start.
I tried using the power injector with a phone and also with a wireless access point, it is working.
I also tried to plug the DMP to a POE switch, the dmp starts.
Is the DMP 4310 compliant with standard power injector ?
Thanks.

Hi,
It seems that the Power Injector delivers enought power but I will try with a PoE+ power injector. In the power injector's datasheet there is nothing about a 802.3af (standard for PoE) compliance so I will try with a compliant power injector. I will let you know if I found the answer.
Thanks.

Similar Messages

  • DMP 4310 5.4 with LG display

    Hi everyone,
    We've got a problem with Cisco DMP 4310 (v. 5.4) and LG display 42WS50. We try to use "Display power on/off" commands via RS-232 but it doesn't work.
    We tried built-in commands for Cisco_32N and also tried to create new system tasks with RS-232 hex codes 6b612030312030310d/
    6b612030312030300d. Prior to sending these commands we enabled RS-232 control but nothing worked.
    Does anyone know maybe there are some issues in new DMP's firmware version?

    We've run into troubles with faulty RS232 cables. Many of our DMPs were wired, but they just weren't receiving commands.
    You might want to try the NEC PDComms tool, which you can download from here:
    http://www.necdisplay.com/support-and-services/pdcommstool/Overview
    With it, you can send RS232 commands from your computer, and view any response from your device. Then you can trouble shoot, at least ruling out the possibility of a faulty peripheral.
    We didn't have any trouble with the 4310 5.4 when we isolated our trouble down to bad cables.
    Good luck!
    -Michael

  • Line Extension with Power Injector: yes or no?

    the lenght of the lan segment between switch and access point is cca 150m.
    my quiestion is:
    can i solve this problem with inserting Power injector (AIR-PWRINJ3) between, so resulting shema would be:
    AP--70m(PoE)--PowerInj--80m(normal LAN)--sw2950
    is it Injector in the function of L2 switch or is it only injecting power into normal 100m limited segment?
    thx for answer

    I tried this before, did not work. I think it's passive.
    You have to use a fiber(MM does the trick and it's cheap, you dont need really clean terminaison for 100baseFX, mecanical with do)
    or put a hub somewere.

  • Aironet 1310, power injector and poe cable

    Hello,
    Can the power injector delivered with aironet 1310 be supplied by a PoE RJ45 cable rather than the traditionnel DC adapter?
    The problem is, i thought Aironet 1310 was PoE. Which means it can be power supplied by a rj45 cable.
    But, when i openned my brand new 1310 box, i realized that 1st, it needs that Power Injector to work and that 2nd, Power injector needs a power supply...
    Usually when i buy a PoE access point, I just plug in my PoE rj45 cable and its power supplied :)
    Anyway, i hope there's an issue for this because where the 1310 should be placed, there's only a PoE rj45 cable arriving.
    Thanks in advance,
    lachapelle

    Hi lachapelle,
    Sadly the 1310 cannot be powered by PoE ,but, the Power Injector can be up to 100 meters away from the unit.
    Dual coaxial cable to run from the power injector to the 1300. See attached notes:
    Cisco Aironet 1300 Series
    Cisco Aironet 1300 Series Access Point/Bridge Power Injector
    The Cisco Aironet 1300 Series Outdoor Access Point/Bridge Power Injector,converts the standard 10/100 BaseT Ethernet interface that is suitable for weather protected areas to a dual F-Type connector interface for coax cables that are more suitable for harsh outdoor environments. The Power Injector also provides power to the outdoor unit over the same cables with a power discover feature and surge protection. To support longer cable runs from your wireless network switch or router, the Power Injector LR is designed to accommodate up to a 100 meter coaxial cable run plus 100 meters of indoor cat5 cable?enabling total cable runs up to 200 meters. The Cisco Aironet 1300 Series Outdoor Access Point/Bridge ships with the Power Injector LR2 and an AC power supply.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a008022551d.html
    Cisco Aironet 1300 Series Outdoor Access Point/Bridge Hardware Installation Guide
    Ethernet Ports
    The access point/bridge dual-coax Ethernet ports consists of a pair of 75-ohm F-type connectors, linking the unit to your 100BASE-T Ethernet LAN through the power injector. The dual-coax cables are used to send and receive Ethernet data and to supply inline 48-VDC power from the power injector to the access point/bridge.
    Power
    The access point/bridge receives inline power from the Cisco Aironet Power Injector (hereafter called the power injector). Dual-coax cables are used to provide Ethernet data and power from the power injector to the access point/bridge. The power injector is an external unit designed for operation in a sheltered environment, such as inside a building or vehicle. The power injector also functions as an Ethernet repeater by connecting to a Category 5 LAN backbone and using the dual-coax cable interface to the access point/bridge.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_installation_guide_book09186a00804d3095.html
    AIR-PWRINJ-BLR2
    F-Type Connectors
    Dual coaxial cable carries full-duplex Ethernet, DC power, and full-duplex console port (RS-232 connection)
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a00802252e1.html
    Hope this helps!
    Rob

  • 1300 Series Access Point/Bridge Power Injector - Using power over ethernet

    Can I use power over ethernet to supply the Injector with power?

    Hi Mikael,
    Sorry, this will not work. Have a look at these specs;
    1300 Series Power
    Power
    The access point/bridge receives inline power from the Cisco Aironet Power Injector (hereafter called the power injector). Dual-coax cables are used to provide Ethernet data and power from the power injector to the access point/bridge. The power injector is an external unit designed for operation in a sheltered environment, such as inside a building or vehicle. The power injector also functions as an Ethernet repeater by connecting to a Category 5 LAN backbone and using the dual-coax cable interface to the access point/bridge.
    The power injector is available in two models:
    Cisco Aironet Power Injector LR2 standard version (included with the access point/bridge)
    48-VDC input power
    Uses the 48-VDC power module (included with the access point/bridge)
    Cisco Aironet Power Injector LR2T optional transportation version
    12- to 40-VDC input power
    Note The power injector and the power module must not be placed in an outdoor unprotected environment. The power module must not be placed in a building's environmental air space, such as above a suspended ceiling.
    http://www.cisco.com/en/US/products/ps5861/products_installation_guide_chapter09186a008079b93b.html#wp1051840
    Dual coaxial cable to run from the power injector to the 1300. See attached notes:
    Cisco Aironet 1300 Series
    Cisco Aironet 1300 Series Access Point/Bridge Power Injector
    The Cisco Aironet 1300 Series Outdoor Access Point/Bridge Power Injector,converts the standard 10/100 BaseT Ethernet interface that is suitable for weather protected areas to a dual F-Type connector interface for coax cables that are more suitable for harsh outdoor environments. The Power Injector also provides power to the outdoor unit over the same cables with a power discover feature and surge protection. To support longer cable runs from your wireless network switch or router, the Power Injector LR is designed to accommodate up to a 100 meter coaxial cable run plus 100 meters of indoor cat5 cable?enabling total cable runs up to 200 meters. The Cisco Aironet 1300 Series Outdoor Access Point/Bridge ships with the Power Injector LR2 and an AC power supply.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a008022551d.html
    Cisco Aironet 1300 Series Outdoor Access Point/Bridge Hardware Installation Guide
    Ethernet Ports
    The access point/bridge dual-coax Ethernet ports consists of a pair of 75-ohm F-type connectors, linking the unit to your 100BASE-T Ethernet LAN through the power injector. The dual-coax cables are used to send and receive Ethernet data and to supply inline 48-VDC power from the power injector to the access point/bridge.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_installation_guide_book09186a00804d3095.html
    AIR-PWRINJ-BLR2
    F-Type Connectors
    Dual coaxial cable carries full-duplex Ethernet, DC power, and full-duplex console port (RS-232 connection)
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a00802252e1.html
    Hope this helps!
    Rob

  • How can I create a folder on internal storage of DMP 4310?

    Hi. I'm a junior engineer in Korea.
    I have a question about DMP 4310 with creating a folder of internal storage.
    I can acess the internal storage but, I cannot make a folder or file uploading.
    I already checked about Access mode - read and write, and also DMP management - FTP Server On, and password too.
    It's enable to read but, unable to make a file or a folder.
    when It rejected my order, I saw a message on my screen like this.
    "550 Create directory operation failed."
    I searched this letters, but couldn't get any information to handle this issue except for showing of permision error message of linux.
    now, I am begging for your kindness.
    what am I suppose to do?

    I checked my permission, and I got the result.
    By the result, I cannot make any folders or files except for path of /usb_1/
    So, I can upload file to /usb_1/ and play it. that's it.
    self question, and self answer... so sad to less people to answer this DMS section...

  • Is switch HP V1910-24G ''JE006A compatible with cisco components such as power injector and cisco SFP

    Hi everbody,
    I need your hand for this case please :)
    this is first time to design outdoor AP, i will use 1532E due to the price is good, but my question is
    * switch HP V1910-24G ''JE006A'' could be compatible with AIR-PWRINJ-30= & SFP cisco 1 G "glc-sx-mmd"
    I am looking for your advice 

    the power injector will work  but the cisco sfp will not work with the HP switch, also i recommend a switch that is already delivering POE+
     

  • Power injector with SPA508g

    I decided to edit this since it got moved to a different place where it might not be understood:
    I have a UC320w phone system. I have SPA508g phones. I have a cisco POE switch next to the UC320. But, I have one far location that has one ethernet port and we want 3 computers and the SPA508g phone. I don't have a POE switch and I'd prefer to put the switch before the phone. (the out port on the phone is 10/100 where I'd like the link to the far switch to be gigabit).
    The SPA508g didn't come with power cords. I know I can get them.
    But I happen to have an Aironet 1200 access point power enjector: AIR-PSINJSYS1200. I think the aironet needs 48 volts, so I assume this power injector provides that (or up to that?).
    Is that ok to use this power injector with a SPA508g? Will it just draw whatever it needs or is that power enjector too much power? I seem some documentation that says the AIR-PSINJSYS1200 will work with a access point that requires less power, but I don't see any other documentation.

    Unfortunately this is the wrong area of the community to pose the question.  While I believe the aironet power injectors present a standard IEEE PoE interface to the device, I can say that for certain.  Certainly those power injectors are only supported for use with the Access Points, and the people who hang on on this community are unlikely to be familiar enough with the product to say for sure whether it will work.  If the injector does present an IEEE PoE interface then the phone should work fine, but I can't confirm that for you.  You might want to try posting a question to the wireless forum at
    https://supportforums.cisco.com/community/netpro/wireless-mobility.
    Cheers,
    Dave.

  • Cisco Power Injector - AIR-PWRINJ4

                       Hi there, I have a quick question about Cisco Power Injector.
                        we bought a number of Air-PWRINJ4 year ago,  mainly for extending the power via Cat5 ethernet cable to AP 1225 in warehouse. the output is 56V 0.55A. 
                        Now I have a couple of spare left, my quesiton is if it is OK to directly power 3502I AP, which requires imput 48V and .35A. from the bag of Air-PWRINJ4, it indecates that the 3500 series is also included.

    HI Scott, thanks for the reply,  I have tested it works fine, but what will happen if we plan to use it for long run, does it will demage the APs?    in the packaging bag it says: Power Injector - AP 1140/1250/1260/3500 Series - SPARE
    on the site I am setting up the AP, there is no POE switch and I don't have adapter with exact output for APs.

  • Power injectors don't work with APs

    Has someone got experience on cisco power injectors for Aironet APs.
    I bought 3 injectors, and 3 power supplys(injectors need power supply, but don't come with the boxes) from cisco.
    I connected a switch(2960) port to the port ‘to network’ on the power injector, and connected a AP(1142N) Ethernet port to the port ‘to Device’ on the power injector.
    The power injector was powered on by the DC supply. But the AP couldn't be powered on by the injector, and the switch port also showed 'noconnect'.
    No particular commands setup on the switch port’s settings.  I tried the switch port auto-auto and 100-full, Vlan access and trunk, but no luck with the injectors.
    Connected the same power supply to the same AP, used the same switch port and same cables, the AP worked fine with the switch.
    Thought of faulty injector, but it's weird that all 3 new purchased injectors are faulty.
    Am I doing anything wrong? do I need to put any commad on switch interface to use power injector?(I cannot believe that)  or just had bad luck of having 3 faulty injectors?
    Please help.  Thanks a lot.

    20W Single Port Midspan
    Have a look at the link above.
    Thanks for the ratings.

  • Help with understanding the show power-injector comand

    I have been battling a connectivity issue between my point to point 1300 bridges. The install is new and the distance between them is about 1881’. There is no LOS problem. I wasn’t sure if it was a power issue ie. the bridge not getting enough power so I issued the show power-injector command. What I find interesting is the difference between up interfaces. The near side bridge shows interface 4 up, were the far side bridge shows interface 4 down. I have read in the documentation, that interface 2-6 should be down, but why is the near side interface 4 up? Would this be causing my connection to be dropping? Are there any major areas of configuration I should be focusing on? The output drops on both radios are high and continue to increment. Any help would be greatly appreciated.
    Near side bridge:
    == Power Injector port 0 speed 100Mb/s duplex full link up enable yes
    tx bytes 64009349963 tx drops 0 tx bcasts 1843004 tx mcasts 1314040
    tx unicasts 56049969 tx collisions 0 tx single collisions 0 tx multiples collisions 0
    tx deferred 0 tx late collisions 0 tx excessive collisions 0 tx frame disc 0
    tx pauses 0
    rx bytes 5872390201 rx undersizes 0 rx pauses 0 rx (<=64 bytes) pkts 23616568
    rx (<=127 bytes) pkts 9328651 rx (<=255 bytes) pkts 4187726 rx (<=511 bytes) pkts 1511066 rx (<=1023 bytes) pkts 554947
    rx oversize 0 rx jabbers 0 rx align errs 0 rx fcs errs 0
    rx good bytes 5872390201 rx drops 0 rx unicasts 40095322 rx mcasts 103347
    rx bcasts 303838 rx SA chngs 11015523 rx frags 0 rx excessive sizes 0
    rx symbol errs 0
    == Power Injector port 1 speed 100Mb/s duplex full link up enable yes
    tx bytes 5863845662 tx drops 0 tx bcasts 303838 tx mcasts 103347
    tx unicasts 39961778 tx collisions 0 tx single collisions 0 tx multiples collisions 0
    tx deferred 0 tx late collisions 0 tx excessive collisions 0 tx frame disc 0
    tx pauses 0
    rx bytes 63836707250 rx undersizes 0 rx pauses 0 rx (<=64 bytes) pkts 6080700
    rx (<=127 bytes) pkts 5492586 rx (<=255 bytes) pkts 4239466 rx (<=511 bytes) pkts 825224 rx (<=1023 bytes) pkts 1044467
    rx oversize 0 rx jabbers 0 rx align errs 0 rx fcs errs 0
    rx good bytes 63836707250 rx drops 0 rx unicasts 56050099 rx mcasts 428404
    rx bcasts 1870745 rx SA chngs 6997560 rx frags 0 rx excessive sizes 0
    rx symbol errs 0
    ==Power Injector port 2 link down
    ==Power Injector port 3 link down
    == Power Injector port 4 speed 10Mb/s duplex half link up enable yes
    tx bytes 265603528 tx drops 0 tx bcasts 2132298 tx mcasts 484525
    tx unicasts 197535 tx collisions 0 tx single collisions 0 tx multiples collisions 0
    tx deferred 0 tx late collisions 0 tx excessive collisions 0 tx frame disc 0
    tx pauses 0
    rx bytes 0 rx undersizes 0 rx pauses 0 rx (<=64 bytes) pkts 0
    rx (<=127 bytes) pkts 0 rx (<=255 bytes) pkts 0 rx (<=511 bytes) pkts 0 rx (<=1023 bytes) pkts 0
    rx oversize 0 rx jabbers 0 rx align errs 0 rx fcs errs 0
    rx good bytes 0 rx drops 0 rx unicasts 0 rx mcasts 0
    rx bcasts 0 rx SA chngs 0 rx frags 0 rx excessive sizes 0
    rx symbol errs 0
    ==Power Injector port 5 is disabled
    ==Power Injector port 6 is disabled
    Far side bridge:
    == Power Injector port 0 speed 100Mb/s duplex full link up enable yes
    tx bytes 5788578922 tx drops 0 tx bcasts 384075 tx mcasts 1045658
    tx unicasts 38083181 tx collisions 0 tx single collisions 0 tx multiples collisions 0
    tx deferred 0 tx late collisions 0 tx excessive collisions 0 tx frame disc 0
    tx pauses 0
    rx bytes 61019612859 rx undersizes 0 rx pauses 0 rx (<=64 bytes) pkts 5523103
    rx (<=127 bytes) pkts 4764259 rx (<=255 bytes) pkts 3856512 rx (<=511 bytes) pkts 783889 rx (<=1023 bytes) pkts 978415
    rx oversize 0 rx jabbers 0 rx align errs 0 rx fcs errs 0
    rx good bytes 61019612859 rx drops 0 rx unicasts 52964546 rx mcasts 349746
    rx bcasts 1513629 rx SA chngs 6169826 rx frags 0 rx excessive sizes 0
    rx symbol errs 0
    == Power Injector port 1 speed 100Mb/s duplex full link up enable yes
    tx bytes 61011915687 tx drops 0 tx bcasts 1513629 tx mcasts 349747
    tx unicasts 52844186 tx collisions 0 tx single collisions 0 tx multiples collisions 0
    tx deferred 0 tx late collisions 0 tx excessive collisions 0 tx frame disc 0
    tx pauses 0
    rx bytes 5630721089 rx undersizes 0 rx pauses 0 rx (<=64 bytes) pkts 22564185
    rx (<=127 bytes) pkts 8895603 rx (<=255 bytes) pkts 3983402 rx (<=511 bytes) pkts 1493247 rx (<=1023 bytes) pkts 531124
    rx oversize 0 rx jabbers 0 rx align errs 0 rx fcs errs 0
    rx good bytes 5630721089 rx drops 0 rx unicasts 38083221 rx mcasts 244739
    rx bcasts 384075 rx SA chngs 10351904 rx frags 0 rx excessive sizes 0
    rx symbol errs 0
    ==Power Injector port 2 link down
    ==Power Injector port 3 link down
    ==Power Injector port 4 link down
    ==Power Injector port 5 is disabled
    ==Power Injector port 6 is disabled

    Hi,
    Actually port on the power injector switch are in auto-duplex and auto-speed mode
    you need to ensure external devices which you connected to power injector switch ports are not hardcoded in full-duplex, they needed to be in auto-duplex mode.
    because in result of duplex mismatch you connection could be slow down and even ports may shutdown.
    and also check both bridge with the latest firmware release
    Cisco Aironet equipment operates best when you load all components with the latest version of the software. 
    You can download the latest software and drivers from the Wireless Downloads Page ( registered customers only) . 

  • DMP 4310 load swf with flashvars

    Hi,
    I am using dmp 4310 and i want to load a swf file using flashvars. This swf is loaded through another swf (a wrapper swf) with the "MovieClip Loader Object" (AS2). When i load the swf using http request i do not have any prblems (eg clipLoader.loadMovie("http://10.0.0.1/swfTest.swf?flashVar1=test1")). The problem is that i cannot get the flashvars by loading the same swf file locally (eg clipLoader.loadMovie("file:///tmp/ftproot/usb_1/files/swfTest.swf?flashVar1=test1")). Is there any way to get the flashvar? Also, is there any way to access the swf file (with the flashvars) using the internal http service (eg http://localhost/...swfTest.swf?flasvar1=test1  -- where localhost is the player itself).
    Thank you in advance for your response!

    Suddenly that code in the following gives me some error
    var langPath = root.LoaderInfo.parameters["xmlFilePath"]+root.LoaderInfo.parameters["lang"];
    my_ssp.xmlFilePath = langPath;
    var fileType = root.LoaderInfo.parameters["xmlFileType"];
    my_ssp.xmlFileType = fileType;
    Access of possibly undefined property LoaderInfo through a reference with static type flash.display:DisplayObject.
    The only code snippet works is
    var paramObj:Object = LoaderInfo(this.root.loaderInfo).parameters;
    for (var param in paramObj) {
       if (param == "xmlFilePath") {
          my_ssp.xmlFilePath = paramObj[param];
       if (param == "xmlFileType") {
          my_ssp.xmlFileType = paramObj[param];

  • Power up cisco 2960 switch with 12V DC Power

    hi all ,
    I have some issue with supply power to cisco 2960-24TT-L switch. In my server farm rack is having DC current of -48V. But however cisco switch require 12V DC current.
    Cisco Spec.
    Cisco Catalyst 2960-24TT-L
    12V at 5 A
    5 A
    How can I power on the switch using DC current ?  Is there any power converter which I can purchase ? your responses are very much.
    Thanks

    You may also go here: 
    https://supportforums.cisco.com/community/netpro/small-business
    The Search Function is your friend.... and Google too.
    How to Secure your Network
    How to Upgrade Routers Firmware
    Setting-Up a Router with DSL Internet Service
    Setting-Up a Router with Cable Internet Service
    How to Hard Reset or 30/30/30 your Router

  • DMP 4310 display autodetection failed

    Dear All,
    We currently test DMP 4310G to display digital signage to displays, but somehow HDMI autodetection failed on most of the displays.
    We have LCD NEC, Samsung, EX90, and CTS500 as display.
    When we connect DMP4310 via HDMI to NEC, Samsung and CTS500, they just blank (even the boot page where IP address is usually shown).
    DMPDM shows that the autodetection is failed.
    But when we connect DMP4310 to EX90, it can display content perfectly.
    I tried to disable autodetection and enter resolution manually ( i checked the datasheet for native resolution of each display ) but still no results.
    I also find this document on Cisco:
    DMP 4310G Notice Regarding HDMI/DVI Effects on Autodetection
    A corner case exists that is mildly disruptive. It is not likely to affect your organization. To understand
    this corner case, assume that all of the following statements are true simultaneously.
    • Your DMP model is 4310G.
    • Your presentation system’s media signal interface is DVI, not HDMI.
    • EDID data in the firmware for your presentation system misrepresents its native resolution.
    • The falsely claimed resolution is an HDMIstandard instead ofa VESA standard.
    In this case, your DMP 4310G proceeds as if the native resolution is low, to ensure that your digital sign
    shows anything at all.
    Any comments are really appreciated
    Best Regard
    Imad

    We've run into troubles with faulty RS232 cables. Many of our DMPs were wired, but they just weren't receiving commands.
    You might want to try the NEC PDComms tool, which you can download from here:
    http://www.necdisplay.com/support-and-services/pdcommstool/Overview
    With it, you can send RS232 commands from your computer, and view any response from your device. Then you can trouble shoot, at least ruling out the possibility of a faulty peripheral.
    We didn't have any trouble with the 4310 5.4 when we isolated our trouble down to bad cables.
    Good luck!
    -Michael

  • Can not find Power Injector for wap2000.

    Hello everybody.
    Not long ago i was bought Cisco wap2000 access point for small business, and now the problem is to find power injector for this device.
    I am already tried to use AIR-PWRINJ3, but access point did't turn on.
    Why?
    Which power injector should i use with this device?
    Thanks.
    PS.
    Please, don't judge me, for my bad english. =)

    I would think that:
    http://www.google.com/products/catalog?hl=en&biw=1168&bih=723&q=cisco+AIR-PWRINJ4%3D&um=1&ie=UTF-8&tbm=shop&cid=1924636136971570879&sa=X&ei=oGf_TcGfHoy40AH2xLDjAg&ved=0CIMBEPICMAU#
    should work, Cisco should be able to confirm . . .
    If not then I would try:
    http://www.versatek.com/products/cisco_power_injector.htm?_kk=cisco%20PoE%20injector&_kt=90d05a21-707c-456a-8dc9-c92b9a334f1b&gclid=CPnpz-nlxKkCFUqM5godGH4Mmw
    I know your original post was in January and you may have created that 100m power cord but I hope this helps others.

Maybe you are looking for

  • Using friends iPods on my iTunes

    I wanted to listen to a friend's iPod selection on my computer. I plugged it in with the cable and my iTunes will recognice the device and show the iPod's contents, but won't let me play them or access them in anyway. Does anyone know why and how to

  • Bug in jhsCommonBeans.vm

    jdeveloper 11.1.2.2.0 jheadstart 11.1.2.1.28 is this a bug? what is the matter? in wizard layout when i generate this warining happened [/WEB-INF/JhsCommon-beans.xml, default/misc/facesConfig/jhsCommonBeans.vm] Velocity log [warn] org.apache.velocity

  • Startup sound

    Can anyone tell me if the Arcana startup sound pane works on the new Alum intel-Imac? I have it installed on my G4 and it works great and I would like to put it on my new iMac. I just don't want to create any problems!

  • Applet needing to access the client system

    Hi, Ive got an applet that I need to be able to launch a .exe that exists on a client's computer...the applet is going to be signed etc. Ive read that it can do this if the client running it explicitly allows the applet access to the required resourc

  • Burning Photos Causes Duplicates

    Hi all: I created an album of photos, and I edited the photos within the album (red light removal, B/W effects, enchancing, etc). I was under the assumption that the changes I made would be saved and therefore overwrite the originals in the albums. I