Cisco MDS 9148 compatibity with EMC VNX 5300

Hi Cisco ,
We have 2 MDS 9148 switches running on NX-OS 5.0(1a). These switches are connected to EMC VNX 5300 currently running on 05.31 version.
We are planning to upgrade both Switches and VNX. 
So my query to you guys is, I am thinking to upgrade Switch to NX-OS 5.2(8c). Will this 5.2(8c) support the VNX 5300 05.32 version.
Please suggest.
Pranav.

Please check
http://www.emc.com/interoperability
and
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/interoperability/matrix/intmatrx/Matrix1.html

Similar Messages

  • Cisco Twinax Cables Compatibiltiy with EMC VNX/VNXe

    Hi,
    I would like to know about Cisco Twinax Cables Compatibiltiy with EMC VNX/VNXe series storage - for connectivity between UCS Fabric Interconnect and EMC VNX/VNXe.
    Are the following Cisco Twinax Cables compatible with EMC's VNX and VNXe serie platforms:
    SFP-H10GB-CU1M= 1-m 10G SFP+ Twinax cable assembly, passive
    SFP-H10GB-CU3M= 3-m 10G SFP+ Twinax cable assembly, passive
    SFP-H10GB-CU5M= 5-m 10G SFP+ Twinax cable assembly, passive
    SFP-H10GB-ACU7M= 7-m 10G SFP+ Twinax cable assembly, active
    SFP-H10GB-ACU10M= 10-m 10G SFP+ Twinax cable assembly, active
    Kindly advice. Thanks.

    Hi,
    I'd like to confirm you, that passive assembly is supported. Haven't tried the actives one yet.
    I'm using UCS-B200 M3, and EMC VNX 5300.
    the EMC VNX5300 (Block Level) connected using 2 type of media. Copper (SFP-H10GB-CU5M= 5-m 10G SFP+ Twinax cable assembly, passive) and Fiber Channel 8 GB directly info Fabric Interconnect 6248 ports.
    For old server the connection is via iSCSI 10GB Copper. and for UCS-B200 M3 is via FC 8GB.
    All my configuration is running well.
    Hope thats helped.
    Thanks,
    Pieter

  • Cisco MDS 9148 compatibility with Finisar FTLF-8524-P2BNV SFP+

    Hello,
    I have a Cisco MDS 9148 switch with Finisar FTLF-8524-P2BNV SFP+ modules. I am told by the guys configuring the equipment that these modules are not identified in the switch interface.
    I am curious if there could be a compatibility problem (I have not found a compatibility list) or any other issue which could cause the behaviour.
    Thank you

  • Cisco MDS 9148 Inventory Collection

    Hi
    I get the following error on an inventory collection of a MDS 9148 (NOS 5.0.4). I have tried deleting and recreating the device.
    RME 4.3.1
    RICS0001:Internal Error,unable to process the collected data from the device.
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.LibInventory.PortInterfaceAGI_RFC1213_HelperMethods,getIfTableEntriesFromDevice,759,Entry speed after if block: 1000000000 Index value : 101191680
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,58,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:populating AssetAG attributes, begins...
    [ Thu Dec 30  13:48:53 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,57,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,64,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:AssetAG Collection aborted com.cisco.nm.xms.xdi.ags.system.CollectionFailedDeviceSensed: java.lang.ArrayIndexOutOfBoundsException: 5 >= 5
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,549,DP time is 20 seconds for 172.23.32.129
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor,458,
    java.lang.NullPointerException
    at com.cisco.nm.rmeng.inventory.ics.invdata.containment.ContainmentAGInvData.compare(ContainmentAGInvData.java:103)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processContainmentAG(InvDataProcessor.java:864)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:330)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,935, Exception occured in process method while processing: 172.23.32.129 null
    ICSException
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:473)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1191,No Trap
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1203,CALLING SELF TEST
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1207,DONE WITH SELF TEST

    Hi Naem,
    have just read the othre reply's, the intresting bit it is in the MDF.
    - <DEVICE NAME="Cisco  MDS 9148 Multilayer Fabric Switch" MDFID="282867260" CISCOMDFID="282867260">
    <SYSOID OID="1.3.6.1.4.1.9.12.3.1.3.841" NAME="OID:1.3.6.1.4.1.9.12.3.1.3.841" />
    The device adds ok, I just can not run an Inventory but can run a backup !
    Thanks

  • Cisco MDS port channel with USC FI

    Hello,
    Can anyone help me to configure/troubleshoot Cisco MDS 9148 with Cisco USC ? M stuck in port channel..i have configured but interfaces are not coming UP.It is showing init state.
    My Topology is like,
    Nexus 5000-->USC FI (single FI) -->Cisco MDS 9148
                                                     --> Two Chassis
    Any help would be highly appreciated...
    Thanx

    TMC-UCSFI-A-A(nxos)# sh interface brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/31     1      NP     off     errDisabled      swl    --           --
    fc1/32     1      NP     off     errDisabled      swl    --           --
    Ethernet      VLAN   Type Mode   Status  Reason                   Speed     Port
    Interface                                                                   Ch #
    Eth1/1        1      eth  fabric up      none                        10G(D) --
    Eth1/2        1      eth  fabric up      none                        10G(D) --
    Eth1/3        1      eth  fabric up      none                        10G(D) --
    Eth1/4        1      eth  fabric up      none                        10G(D) --
    Eth1/5        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/6        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/7        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/8        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/9        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/10       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/11       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/12       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/13       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/14       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/15       1      eth  trunk  up      none                        10G(D) 100
    Eth1/16       1      eth  trunk  up      none                        10G(D) 100
    Eth1/17       1      eth  fabric up      none                        10G(D) --
    Eth1/18       1      eth  fabric up      none                        10G(D) --
    Eth1/19       1      eth  fabric up      none                        10G(D) --
    Eth1/20       1      eth  fabric up      none                        10G(D) --
    Eth1/21       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/22       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/23       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/24       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/25       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/26       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/27       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/28       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/29       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/30       1      eth  access down    SFP not inserted            10G(D) --
    output ommitted
    TMC-UCSFI-A-A(nxos)#
    Here it shows that Fc1/31- 32 which are in trunk , status is errdisabled and admin trunk mode is off

  • Using Cisco MDS 9148 switch for switching and routing

    Hi Gurus,
    Can you please advice me! Can i configure interface trunking, routing and dhcp services on the Cisco MDS 9148 switch?
    Thanks for your response!!

    Tommy,
    MDS9148 is a Storage SAN Fibre Channel switch, it doesn't support Ethernet, IP, VLANs, VLAN trunking, 802.1Q, IP routing, DHCP. It's meant for Fibre Channel connectivity between Fibre Channel server HBAs and Fibre Channel storage.
    Roman

  • Login CLI Cisco MDS 9148 Multilayer

    When I try to enter the Cisco MDS 9148 Multilayer switch through the command line, new is not yet configured, shows the following message:
    mdssw4 login: cisco                   
    Password:         
    Login incorrect               
        THIS IS A DEPARTMENT OF DEFENSE  COMPUTER  SYSTEM.  THIS COMPUTER SYSTEM                                                                            
        AND ALL RELATED  EQUIPMENT AND NETWORKS ARE PROVIDED ONLY FOR AUTHORIZED                                                                            
        US GOVERNMENT USE.  DOD COMPUTER SYSTEMS MAY BE MONITORED FOR ALL LAWFUL                                                                            
        PURPOSES,  INCLUDING  ENSURING  AUTHORIZED  USE, FOR  MANAGEMENT  OF THE                                                                            
        SYSTEM, TO FACILITATE  PROTECTION  AGAINST  UNAUTHORIZED  ACCESS, AN                                                                      
        VERIFY  SECURITY  FEATURES OR  PROCEDURES.  ALL  INFORMATION,  INCLUDING                                                                            
        PERSONAL  INFORMATION,  PLACED  ON OR  SENT  OVER  THIS  SYSTEM,  MAY BE                                                                            
        MONITORED.              
        USE OF THIS DOD COMPUTER SYSTEM, AUTHORIZED OR UNAUTHORIZED, CONSTITUTES                                                                            
        CONSENT TO MONITORING OF THIS SYSTEM.  UNAUTHORIZED  USE MAY SUBJECT YOU                                                                            
        TO CRIMINAL  PROSECUTION.  EVIDENCE OF UNAUTHORIZED USE COLLECTED DURING                                                                            
        MONITORING  MAY BE USED FOR  ADMINISTRATIVE,  CRIMINAL, OR OTHER ADVERSE                                                                            
        ACTION.      
    how do I get the username and password.

    good one ;)

  • Direct connect to UCS FI from EMC VNX 5300

    Hi,
    I'm looking for any configuration recommendations or best practices for configuring a VNX 5300 unified for direct connect to UCS Fabric Interconnects.
    The direct connect wil be 10GB on both the file and block side.
    Are their any guides or recommendations anyone may have?
    I've looked and cannot find much.

    Hi Manuel,
    Two things:
    1) Take a look at the following matrix for the supported version
    http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/Matrix8.html
    2) Currently the direct attch FC is supported under a restricted to topologies in which the zoning  database is provided from an upstream Cisco MDS 9000 switch or Nexus  5000 or 5500 switch. Hence you would still have to conenct an MDS or a N5K to the FIs for the zoning info.
    ./Abhinav

  • Cisco MDS 9148 fcalias PWWN update

    One of the network/hba modules died on one of our blade and we had to replace it. Because of this I need to update the PWWN for the FCALIAS. It's been a while but I think it is simple as getting in to the fcalias, adding the new pwwn and removing the old one. Can someone please verify or correct?
    config t
    fcalias name BLADE_ESX_HBA1 vsan 2
      no pwwn 10:00:00:00:00:00:00:60
         pwwn 10:00:00:00:00:00:d0:60
    Any suggestions or best practices are welcome! thanks. 

    Hi Dennis,
    If zone mode is "basic":
    switch# show zone status vsan 2
    VSAN: 2 default-zone: deny distribute: active only Interop: default
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: unsupported
        smart-zoning: disabled
        rscn-format: fabric-address
    switch# conf t
    Enter configuration commands, one per line.  End with CNTL/Z.
    switch(config)# fcalias name BLADE_ESX_HBA1 vsan 2
    switch(config-fcalias)# no member pwwn 10:00:00:00:00:00:00:60
    switch(config-fcalias)# member pwwn 10:00:00:00:00:00:d0:60
    switch(config-fcalias)# end
    switch# show fcalias vsan 2
    fcalias name BLADE_ESX_HBA1 vsan 2
      pwwn 10:00:00:00:00:00:d0:60
    switch#  copy running-config startup-config
    If zone mode is "enhanced":
    switch# show zone status v 2
    VSAN: 2 default-zone: deny distribute: full Interop: default
        mode: enhanced merge-control: allow
        session: none
        hard-zoning: enabled broadcast: unsupported
        smart-zoning: disabled
        rscn-format: fabric-address
    switch# conf t
    Enter configuration commands, one per line.  End with CNTL/Z.
    switch(config)# fcalias name BLADE_ESX_HBA1 vsan 2
    switch(config-fcalias)# no member pwwn 10:00:00:00:00:00:00:60
    Enhanced zone session has been created. Please 'commit' the changes when done.
    switch(config-fcalias)# member pwwn 10:00:00:00:00:00:d0:60
    switch(config-fcalias)# exit
    switch(config)# zone commit vsan 2
    switch(config)# exit
    switch# show fcalias vsan 2
    fcalias name BLADE_ESX_HBA1 vsan 2
      pwwn 10:00:00:00:00:00:d0:60
    switch#  copy running-config startup-config

  • Interconnecting MDS 9148 with 2 different Fiber Providers

    Hi
    I would like discuss the following issue :
    We have 2 HP SAN EVA 8400 ( one at the production site and one at our Disaster Recovery site ) replicating using a fiber channel service from ( 2* FC dark fiber from PROVIDER A )
    They are linked together  with 4 Cisco MDS 9148 Multilayer Fabric Switch (2 fabric ). 
    We have recently purchased a new fiber service ( 2* 1Gb FC managed service from PROVIDER B) in order to create a port channel  with the 2 running ones and we have some problem.
    We disconnected the PROVIDER A FC ( running for 10 years now )  and left the SAN replication during a couple of days running with the new PROVIDER B 1 Gb FC to make sure the link was stable and we had no issue.
    Then we tried to connect the 2 FC together from the 2 providers and tried to create a Port channel.
    However we discovered that to create a PortChannel, interfaces must have the same configurations ( speed, mode, rate )
    In our case , the interface FC 1/1 using PROVIDER A link is running at 4 Gb and the interface FC 1/2 using PROVIDER B is running at 1 Gb
    PROVIDER A dark fiber
    PROVIDER B fiber managed service
    fc1/1 is trunking
        Hardware is Fibre Channel, SFP is CWDM-1550
        Port WWN is 20:01:00:05:9b:72:b1:60
        Peer port WWN is 20:01:00:05:9b:72:b1:a0
        Admin port mode is E, trunk mode is on
        snmp link state traps are enabled
        Port mode is TE
        Port vsan is 1
        Speed is 4 Gbps
        Rate mode is dedicated
        Transmit B2B Credit is 32
        Receive B2B Credit is 32
        B2B State Change Number is 14
        Receive data field Size is 2112
        Beacon is turned off
        Trunk vsans (admin allowed and active) (1)
        Trunk vsans (up)                       (1)
        Trunk vsans (isolated)                 ()
        Trunk vsans (initializing)             ()
        5 minutes input rate 4416 bits/sec, 552 bytes/sec, 6 frames/sec
        5 minutes output rate 91616 bits/sec, 11452 bytes/sec, 11 frames/sec
          51537358280 frames input, 50955393731852 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          223256095067 frames output, 408667816663528 bytes
            32 discards, 0 errors
          34 input OLS, 36 LRR, 51 NOS, 0 loop inits
          53 output OLS, 35 LRR, 45 NOS, 0 loop inits
          32 receive B2B credit remaining
          32 transmit B2B credit remaining
          28 low priority transmit B2B credit remaining
        Interface last changed at Fri Dec 14 17:02:48 2012
    fc1/2 is trunking
        Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
        Port WWN is 20:02:00:05:9b:72:b1:60
        Peer port WWN is 20:02:00:05:9b:72:b1:a0
        Admin port mode is E, trunk mode is on
        snmp link state traps are enabled
        Port mode is TE
        Port vsan is 1
        Speed is 1 Gbps
        Rate mode is dedicated
        Transmit B2B Credit is 32
        Receive B2B Credit is 32
        B2B State Change Number is 14
        Receive data field Size is 2112
        Beacon is turned off
        Trunk vsans (admin allowed and active) (1)
        Trunk vsans (up)                       (1)
        Trunk vsans (isolated)                 ()
        Trunk vsans (initializing)             ()
        5 minutes input rate 48 bits/sec, 6 bytes/sec, 0 frames/sec
        5 minutes output rate 48 bits/sec, 6 bytes/sec, 0 frames/sec
          39496053 frames input, 2696451760 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          167653989 frames output, 230540944084 bytes
            70 discards, 0 errors
          40377 input OLS, 345 LRR, 4248 NOS, 0 loop inits
          5186 output OLS, 1154 LRR, 39568 NOS, 0 loop inits
          32 receive B2B credit remaining
          32 transmit B2B credit remaining
          28 low priority transmit B2B credit remaining
        Interface last changed at Fri Dec 14 16:50:42 2012
    So we tried to force the FC 1/1 to run at 1 Gb ( same speed as FC 1/2 ) to create the PortChannel, by doing the basic command on the interface : Switchport speed 1000
    Since that , our SAN is logging every 10/15 minutes the following errors :
    ---------- Problem Found: CUST: CA informational: EVA8400_LIVE: Write resources on the inter site link have been reduced. at Fri 14 Dec 2012 17:21:04 GMT+01:00 ----------
    ---------- Problem Found: CUST: CA warning: EVA8400_DR: Excessive out of order message rate on the inter site link. at Fri 14 Dec 2012 17:27:04 GMT+01:00 ----------
    ---------- Problem Found: CUST: CA warning: EVA8400_DR: Excessive data exchange retry rate on the inter site link. at Fri 14 Dec 2012 17:41:34 GMT+01:00 ----------
    ---------- Problem Found: CUST: CA warning: EVA8400_LIVE: Excessive data exchange retry rate on the inter site link. at Fri 14 Dec 2012 17:41:49 GMT+01:00 ----------
    We have the following questions :
    Have you already seen that kind of situation ?
    Is there a best practice  to reduce the interface speed in order to create the PortChannel with identical interface setup ?
    Your help and advice would be much appreciated.
    Regards

    the RTT delay by each link is different and this is causing packets to arrive out of order.
    not sure if port channeling between two different links or different characteristics is good practive.

  • How to use syslog with a MDS 9148

    Hi,
    I'm looking for some informations regarding MDS-9148 and syslog.  I need for some security needs, to send the events of a cisco MDS-9148 into a syslog server.
    I did the following commands:
    config t
    logging server xxx.xxx.xxx.xxx
    logging commit 
    --> When i executed the command "logging commit", the switch has return to me the following error message:
         CFS distribution is not enabled for logging
    It's a FC switch, so the only IP link should be for the management.
    Must i do something related with CFS to enable logging events to syslog server ?  I've checked with our network admin that uses Nexus switch and he doesn't seem to use CFS for it's logging to a syslog server.
    Thank you,
    Chris

    Hi Paresh,
    Thank you for you answer.  It confirm what our network admin showed me.  However, it is not working i'm still getting the the message: CFS distribution is not enabled for logging
    If i run the command: show cfs status, i receive the following information
    Distribution : Enabled
    Distribution over IP : Disabled
    IPv4 multicast address : xxx.xxx.xxx.xxx
    IPv6 multicast address : xxxx::xxxx:xxxx
    Distribution over Ethernet : Disabled
    We are pretty sure we aren't using CFS.  In one of our datacenter, we got 2 switchs 9148 configured with NPV.  The other datacenter  has only 1 switch per fabric. 
    Am i getting the CFS message because it is actually "Enabled" ?
    I did a show runnin-config cfs, to see if there was a configuration done of CFS, but there is none.
    Can i "Disable" it without causing issue ?
    Thank you for the help you can provide,
    Chris

  • Troubleshoot connectivity with Cisco MDS 9124

    Hello,
    I recentrly discovered that it's become impossible to connect to a CISCO MDS 9124, neither with SSH nor with Serial connection.
    What should i do please to resolve that issue please?
    Regards!

    Hi,
    Are you able to access the 9124 by Device Manager, web browser, telnet, or ssh when your laptop is directly connected to the mgmt0 interface and your laptop configured on the same subnet as the mgmt0 interface?
    What console settings, console cable, terminal emulator application are you using and does it work with another MDS9000?
    Regards,
    David

  • Fabric Interconnect To MDS 9148 FC Port Channel/Trunks

    Is it possible to create both a Port Channel and Trunk on a Cisco MDS 9148? Yes correct?
    Or can I only trunk between the 2 MDS switches and not the MDS to Fabric Interconnect?
    These FC links would be connected to a 2248XP Fabric Interconnect carrying multiple VSANs from the MDS to the Fabric Interconnect.
    Thanks

    Hello,
    Yes, you can have trunk links grouped into port channel ( F port-channel trunking ) between FI and MDS.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html
    Padma

  • Monitoring for Cisco UCS/Cisco Catalyst/EMC VNX/VMware environment

    hi
    I am not sure whether this is the right place for this post, but I am giving it a shot anyway.
    I am looking for a monitoring solution for a Cisco UCS/Cisco Catalyst/EMC VNX/VMware environment and I cannot seem to find 1 product that does it all.
    Do any of you Guys have experience with a such product?
    thanks...

    I have used PRTG for Cisco Routers/Switch, Vmware  and with Cisco UCS. As for the storage part I'm not sure.
    I recommend prtg because its user friendly and web based management.
    Please Rate.

  • Cisco MDS Vsan for EVA8100 and EMC Clariion (Same or Seperate)

    We have EMC Clariion Frame CX600,CX700 and Cisco MDS Fabric with 2 VSANS currently.
    We have just procured EVA8100 and wanted to find out, do we create 2 additional VSANS to support it or add EVA8100 in the existing VSANS.
    IVR is not enabled on Cisco MDS.
    Also we'll be phasing out the EMC frames and want to migrate data from Clariion LUNS , so debating to put EVA8100 in same VSANS, so data can be migrated over same VSANS.
    Also heard that earlier if EMC Clariion was brought online before EVA frame then CommandView would not find EVA, so EVA needs to be booted first (May have been fixed).
    Thanks

    G'day,
    You do not need to create new vsan's when adding new devices to a fabric. You will however need to change the zoning configuration to allow hosts to see the newly attached storage array.
    VSAN's are a way of segregating traffic within a single physical fabric. One good method of using them is to segregate development from production traffic.
    For further info on VSAN's see "http://www.cisco.com/en/US/netsol/ns340/ns394/ns259/ns261/networking_solutions_white_paper09186a0080114c21.shtml"
    Cheers

Maybe you are looking for

  • Copy file from client machine to unix db server

    Dear all, I have oracle form 10g, and data base server using 10 r 2, I have an oracle for to browse client XML file and return the name of the file including the path to TEXT item what I want to do after that is to copy the seelcted file from the cli

  • Can't Edit Contacts - can't export them to re-import them!

    Hi everyone,  After updating my Bold 9700 to OS6 I accidentally synced contacts with Facebook and gmail, causing duplicate entries. Not just a few, but practically every person I know now has 3-7 contacts, and some are even blank.  I'd love to be abl

  • How to erase harddrive

    Back again, bought a new MB Air andmoved all the contents from my old MB Pro pro through timemachine with no issue (10.8.2 on both). Now I am trying to erase all data on my old MB Pro and reinstal mountain lion (10.8.2). Somehow the Disk Utility on t

  • Current date should be populated when executing the hierachy variable.

    Hi bw Pro's I have a customer hi-erachy.For that hierachy i created a variable. The variable name is hieraachy date. the variable will be executed with  user entry/default value. the characteristic i used for thata variable is date. Now the requireme

  • HT201274 How can I enable an iphone that's disabled?

    I recently received a used iphone4s from mother and it is currently disabled. I cannot get in it to restore it to switch to my phone number. Please help