Cisco Nexus 5596 and Brocade 5300 compatibility
Hi
We have designed the SAN network with Brocade5300 connected to Nexus5596. we want to know about the campatibility of these two switches.
I can't find any compatibility matrix with this detail.
i would appreciate it if you let me know about your experience.
Thank you
Amir,
Check this.
http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/Matrix7.html
I am not sure how recent it is and when this testing was done. I would suggest you to run " Gateway mode" AKA NPIV mode for Cisco and test this with Brocade 5300. It should work fine.
Hope this helps.
Cheer,-amit singh
Similar Messages
-
Cisco Nexus 5548UP and FI6248UP compatibility with FC SFP
Cisco Nexus 5548UP and FI 6248UP comes with Unified Ports. What are the SFP types this port can take? 1Gig, 10Gig and 2/4/8FC. Could you please clarify?
Thanks,
CheriyanHi Cheriyan,
Here is te URL to the 6200 series FI data sheet:
http://www.cisco.com/en/US/prod/collateral/ps10265/ps11544/data_sheet_c78-675245.pdf
Check for the table to supported SFPs.
Same for the 5500 switches
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/data_sheet_c78-618603.html.
Hope this helps!
./Abhinav -
Hello Friends,
Just want to save your precious time & effort, while doing Nexus 5596 upgrades so wanted to share some useful info which you can have a look prior to your upgrades of Cisco Nexus 5596 device.
I recently ran into trouble when upgarding one of datacenter switch Nexus 5596 does not boots up and after investigation from Cisco TAC it comes out to be Bug documented below.
https://tools.cisco.com/bugsearch/bug/CSCun66310/?reffering_site=dumpcr
My Upgrade path of device was : 5.1(3)N1(1) to 6.0(2)N2(5).
Since this upgarde involves upgrade of Bios and Power sequensor, I was having some doubts to get this succesfully upgraded, But there was more twist involved in this upgrade which I came to know after contacting Cisco TAC for my died Nexus 5596 device and got info that if you have below impacted version in your Nexus 5596 device and you are planning to do Upgrade, then you migh RUN into this serious BUG aftre which device won't come up at all and only Option left is to replace with RMA device.
PID Impacted Hardware versions Updated Versions
UCS-FI-6296UP 1.0 1.1
N5K-C5596UP 1.0 1.1
N5K-C5596T 1.1 1.2
You can check hardware version using below command from your device.
5596# show sprom sup | inc H/W
H/W Version : 1.1
So please be carefull when planning your Nexus 5596 upgrade and verify above things as this Bug is not present anywhere in Upgrade docuemntations unfortunately.
Hope this will help and save someone's precious Time.Today "upgraded" our switch (N5k-C5596UP) to from 5.1(2)N1 to 7.0(5) and after reboot no life from the switch either. Even no console response. show sprom sup | inc H/W shows 1:0.
Only thing we could do is RMA the switch. So what must I do with these switches? Have still to do 3 of them. -
Trunking nexus 5596 and netapp or exsi issue
hi
i have 2 issues with trunking between nexus 5596 and a esxi server .....can not get the servers to ping out
and the netapp connected to the same 5596 cannot ping.
if the server is a access port it works fine.
is there any tricks that are required to be configured on the nexus to make this work.Make sure we are actually tagging for those vlans on the host (Netapp/ESXi). If we are not, then this would explain why it works in access mode on the switch.
-
Nexus 5596 and QOS config guide
Hi,
I need to implement qos on a nexus device for a client
Basically what I am trying to implement is this but on the nexus
Policy Map Enhanced_QoS_Customer_Out
Description: Enhanced QoS customers outbound Percentages
Class Cust_VoIP_Out
priority 30 (%)
Class Cust_Gold_Out
bandwidth 30 (%)
Class Cust_Silver_Out
bandwidth 13 (%)
Class Cust_Bronze_Out
bandwidth 2 (%)
Policy Map Ethernet_QoS_Customer_Out_200Mb
Class class-default
Average Rate Traffic Shaping
cir 200000000 (bps)
service-policy Enhanced_QoS_Customer_Out
Is this possible on the nexus 5596?
I havent found much information around shaping.. Please advise if the above policy is achelievable on the nexus and if not what does the nexus support?
regards,Hi,
I don't think the 5500 support shaping since it is mostly a layer-2 device. Here is the config guide for QOS.
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/configuration/guide/cli/CLIConfigurationGuide/QoS.html
HTH -
Cisco Nexus 5548UP to Brocade SAN Connectivity
Hi,
I have a Server-SAN-Storage setup as shown in the attachment/below. There are new Cisco UCS rack mount servers with VIC 1225 and Virtual servers on VMware Esxi hypevisor connected to a new Cisco Nexus 5548UP switch in IP+FCoE mode. The new 5548 switch then connects to an existing production SAN of Brocade 48000 Director SAN switch which connects to storage in production environment.
I need to know the best way to connect the 5548 switch to the Brocade SAN switch without disrupting the existing Production SAN environment i.e. Brocade SAN switch configurations & setup e.g. Fabric Principal switch. priority etc.
Would configuring the 5548 switch in NPV mode be best practice?See Figure 6-2 Converged Multi-hop FCoE Network Design Using FCoE NPV
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/operations/fcoe/513_n1_1/ops_fcoe/ops_fcoe_npv.html
You have to use NPV on N5k, there is no FC interop support on N5k, to connect to Brocade. -
SAN Port-Channel between Nexus 5000 and Brocade 5100
I have a Nexus 5000 running in NPV mode connected to a Brocade 5100 FC switch using two FC ports on a native FC module in the Nexus 5000. I would like to configure these two physical links as one logical link using a SAN Port-Channel/ISL-Trunk. An ISL trunking license is already installed on the Brocade 5100. The Nexus 5000 is running NX-OS 4.2(1), the Brocade 5100 Fabric OS 6.20. Does anybody know if this is a supported configuration? If so, how can this be configured on the Nexus 5000 and the Brocade 5100? Thank you in advance for any comments.
Best regards,
FlorianI tried that and I could see the status light on the ports come on but it still showed not connected.
I configured another switch (a 3560) with the same config and the same layout with the fiber and I got the connection up on it. I just cant seem to get it on the 4506, would it be something with the supervisor? Could it be wanting to use the 10gb port instead of the 1gb ports? -
Cisco LAN Management Solution is required to support Cisco Nexus 5548P and 5596UP switches?
Hi,
Could someone help to know what Cisco LAN Management Solution is required to support Cisco Nexus 5548P switches and Cisco Nexus 5596UP switches?
These new Cisco switches are being implementing on customer network and he ask us that he requires these equipments be supported on a LMS solution (customer currently is using LMS 3.2.1)
Can someone help?
Thanks in advanced,
guruizSome very limited Nexus support is present in LMS 3.2.1 - see the supported device table here.
To get more complete support, including the 5596UP, they need to upgrade to LMS 4.x (e.g. LMS 4.2.2 is the latest and is sold under the Cisco Prime Infrastructure 1.2 umbrella). The major upgrade from 3.x to 4.x requires purchasing an upgrade license.
Some functions (namely User Tracking ) will not be available on the 5k due to non-support of the requisite MIB on the device. I believe LMS still doesn't let you do VLAN management on 5k's - you need to use DCNM for that if you want to do it from a GUI.
See the table here for LMS 4.2 device support. -
Interoperability between Cisco Nexus 5548UP and IBM FC3171
Dear Techies,
We have a Cisco Nexus Switch 5548UP already in our environment with DS-SFP-FC8G-SW installed. We are planning to procure IBM Pure Flex Chassis without FC Switch, since we already have Nexus that can provide this facility. But in order to connect IBM Flex with Cisco Nexus we are planning to use IBM FC3171 Switch with IBM 44X1964 Transceivers which will act as a Mediator/Pass Through Switch for connecting IBM and Cisco.
If any expert knows OR have used this scenario, please let me know since I am interested to know if it will work in this scenario or not.
Regards,
Farhan.Dear prkrishn
I am working on the Data Center Solution between two Data Center, details underneath
DC 1 Site
1. 2 x DC Core Switch (Nexus 7009) - will be used for Servers, Application, IBM V7000, Database, etc.
2. 2 x Network Core Switch (Cisco 6509) - Handle Campus and Inter Building connection.
3. IBM V7000 (SAN)
DC 2 Site
1. 2 x DC Core Switch (Nexus 7009) - will be used for Servers, Application, IBM V7000, Database, etc.
2. 2 x Network Core Switch (Cisco 6509) - Handle Campus and Inter Building connection.
3. IBM V7000 (SAN)
With the above mention setup, can I configure FCIP between DC1 & DC2 using Nexus 7009? or I need FCIP capable Switch such as IBM SAN Switch (SAN06-BR), I was wondering if I can configure FCIP on Nexus 7009 DC Switch.
Hoping for your kind response at earliest.
Kind Regards,
Arnold -
I am having a problem with getting the Qlogic 8150 working in a windows 2008 R2 server. I have the SAN connectivity working but I am having problem with the networking.
I have setup VLAN 666 as the data vlan
On the ethernet trunk I have setup
ethernet 1/17
switchport mode trunk
switchport trunk allowed vlan 666 spanning-tree port type edge trunk
This does not work but if I allow VLAN 1 on the trunk it works and I have full IP connectivity.
switchport trunk allowed vlan 666,1 Any ideas why adding VLAN 1 on the trunk makes everything workThanksYou set vlan 666 as the VlanID under the Qlogic adapter advanced properties, right? Should be the last value in the scroll box.
-
In this document:
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/operations/interfaces/602_n1_1/N5K_Interfaces_Ops_Guide/n5k_qsfp-_portsoperations.html
I read that "There is no additional configuration needed to specify the operation mode of the QSFP+ ports because all the ports only operate in 4 x10 Gigabit Ethernet mode". Is this hw or sw related? If sw, when will it be available for running 40G instead og 4x10G?
GeirHi,
I don't think the 5500 support shaping since it is mostly a layer-2 device. Here is the config guide for QOS.
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/configuration/guide/cli/CLIConfigurationGuide/QoS.html
HTH -
VPC trouble - link flapping between C3750 stack and Nexus 5596
Hi All,
I have configured 1 vPC's between 2 Nexus 5596 and 1 stack C3750 switch. The links in the stack are distributed over both members.
Gi1/1/1 -> Eth 1/44 NX 5596-02
Gi 2/1/1 -> Eth 1/45 NX 5596-02
Gi 1/1/2 -> Eth 1/46 NX 5596-01
Gi 2/1/2 -> Eth 1/47 NX 5596-01
The same logic is for another stack C3750 to the same pair of Nexus 5596 switches.
The problem is that the links from the vPCs keep flapping at random moments - 1-2 times per hour.
The network is not loaded at this time and the same issue is on both vPC's.
the flaps in the nexus 5596 looks like this
%ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel108: Ethernet1/44 is down
%ETH_PORT_CHANNEL-5-FOP_CHANGED: port-channel108: first operational port changed from Ethernet1/44 to Ethernet1/45
%ETHPORT-5-IF_DOWN_INITIALIZING: Interface Ethernet1/44 is down (Initializing)
%ETH_PORT_CHANNEL-5-PORT_UP: port-channel108: Ethernet1/44 is up
%ETHPORT-5-IF_UP: Interface Ethernet1/44 is up in mode trunk
On the stack is just up/down the pair interface.
I started few debugs on the stack and captured the folowing output:
C3750X-02#im_if_stack_relationship_add: Posting the ACP job for stack add for 5018.10902
im_if_stack_relationship_add: Posted the ACP job for stack add successfully
im_add_ifstackentry: higher_if_index = 5018 lower_if_index = 10902
im_add_ifstackentry: Failed to delete nolayerelem from NoLowerLayerTree for higher_ifIndex = 5018
im_add_ifstackentry: Failed to delete nolayerelem from NoHigherLayerTree for lower_ifIndex = 10902
im_add_ifstackentry: Deleted nolayerelems from NoHigherLayerTree and NoLowerLayerTree
im_add_ifstackentry: Failed to insert stackelem into StackTree
Jul 12 03:35:26.122: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet2/1/2, changed state to downim_if_stack_relationship_add: Posting the ACP job for stack add for 5018.10902
im_if_stack_relationship_add: Posted the ACP job for stack add successfully
im_add_ifstackentry: higher_if_index = 5018 lower_if_index = 10902
im_add_ifstackentry: Failed to delete nolayerelem from NoLowerLayerTree for higher_ifIndex = 5018
im_add_ifstackentry: Failed to delete nolayerelem from NoHigherLayerTree for lower_ifIndex = 10902
im_add_ifstackentry: Deleted nolayerelems from NoHigherLayerTree and NoLowerLayerTree
im_add_ifstackentry: Failed to insert stackelem into StackTree
Jul 12 03:35:29.058: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet2/1/2, changed state to up
Do someone have any idea what happens here ?
The configuration is ok because i have another vPC connected to FEX's and is working fine.
Kind regards,Hello,
Problem solved after upgrade to the last version of NX OS 6.0.2.N2.3
BR, -
How to download MIB for NXOS or platform Nexus 7010 and Nexus 7004
Hello,
I need to monitor my Nexus 7004 and 7010 by my SNMP Agent, but I can't find the way to donload the required MIBs.
For information I'm running the folling images:
bootflash:///n7000-s2-dk9.6.2.6b.bin
bootflash:///n7000-s1-dk9.6.1.5.bin
By advance thanks for the support
GildasThe module you are running requires a minimum software version of 5.1.
You are currently running 5.0.3 which is why the module is not
recognized.
Below is a link that explains this:
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/data_s
heet_c78-605482.html
Product Specification
Table 3 lists the specifications for the Cisco Nexus 7000 32-Port 10 Gigabit Ethernet
Module with XL Option.
Table 3. Product Specifications
Item
Specifications
System
Product compatibility
Supported in all Cisco Nexus 7000 Series chassis
Software compatibility
Cisco NX-OS Software Release 5.1 or later (minimum requirement)
You would need to upgrade you software.
Hope this helps.
Regards
Muhammed M -
Nexus 5596 Ethernet Port Configuration
I have a Cisco Nexus 5596 with 48 Ethernet Ports (two of which are now configured for Fibre Channel). It has a FEX attached to it as well.
I was able to configure ANY Ethernet port with the typical interface commands when in interface configuration mode. However, I can now only configure existing and new Port Channel interfaces, FEX ports and standard Ethernet ports that have never been configured before.
If I try to configure an Ethernet interface that was configured in the past, I only seem to have access to global interface commands when in interface configuration mode. I can set spanning-tree, duplex, speed or any other interface parameters. The CLI acts like I'm not in interface config mode, but the prompt shows that I am.
Anyone else seen such a thing? I am logged in as admin.Hi Mark
I suspect the interface in question is configured to be in a channel. Once an ethernet interface is configured to be in a port-channel. most interface commands need to be configured under the port-channel interface
Thanks
-Prashanth -
Nexus 5596 FC-Port Link-Events
Hi all,
int the last 3 weeks,
almost every day , we have a series of events in the connection between one Nexus 5596 and one of our servers. The connection is in FC (4G).
I need help to understand the output of the following command to troubleshoot what could be happening.
Sw-cpd-mm-n5k-2# show hardware internal fc-mac 3 port 14 link-event
MMDDYY HHMMSS usecs Event Current State
- - LINK_ACTIVE
100113 020845 773895 (0001) E_LINK_IDLE LINK_LRR_RX
100113 020845 765016 (0000) E_LINK_LRR LINK_LR_TX
100113 020845 763545 (61CB28) E_LINK_LINK_RESET LINK_ACTIVE
Sw-cpd-mm-n5k-2# show hardware internal fc-mac 3 port 14 port-event
MMDDYY HHMMSS usecs Event Current State
- - IPS_LINK_UP
100113 020845 775908 (0000) E_IPS_LINK_INIT_SUC IPS_LINK_UP
100113 020845 775907 (0000) E_IPS_IDLE IPS_LINK_UP
100113 020845 770040 (0001) E_IPS_LRR IPS_LINK_UP
100113 020845 763562 (61CB28) E_IPS_CREDIT_LOSS IPS_LINK_UP
Looking at the output I don't know who generates "E_LINK_LINK_RESET" , Nexus switch or server?
Thanks in advance!Hi,
I know it is a little bit late, but hope it can still be of use...
According to the log output, The switch detects a Credit Loss condition
00113 020845 763562 (61CB28) E_IPS_CREDIT_LOSS IPS_LINK_UP
and to recover from it, the switch resets the link by sending a LR to the server
100113 020845 763545 (61CB28) E_LINK_LINK_RESET LINK_ACTIVE
the server replies with a LRR, IDLE, etc.
100113 020845 765016 (0000) E_LINK_LRR LINK_LR_TX
Kind rgds,
Felipon
Maybe you are looking for
-
I lose the number of a iTunes gift card when I scratch it!
Can I recover my code for a damash itunes gift card?
-
On Business Intelligence Prompt
Hi All, This is very critical in this project. Could you please help me out. Problem: I have a report where one of the column is Fiscal Year. There is a Fiscal Year prompt where I am using "between" operator to select between 2006 and 2010 year. That
-
n5233 hd game suppted ya not . . Othrbys nt . . Hw to ply hd game in 5233 . . .plz any solution . . .tell me
-
What is the correct way to dynamically change the View?
hi @, In my application I have a radiobuttonbyKey UI element and based upon the key I have to hide and/or show a particular UI combination placed in the group UI element basically dynamicallly modifying the view. I have 2 option one on radio button a
-
Warning Itouch 3.1.1 software upgrade
I believe several people are experiencing problems with certain itouch 2G upgrading to 3.1.1. I was lucky that my iphone had no problems with the upgrade to 3.1.1. My itouch on the other hand will no longer play and videos or songs. Apple is replacin