Cisco UCS and VNX Initiators

I am installing a new UCS blade system connecting it to a VNX5300 at our disaster recovery site. We are installing ESXi 5.0 Update 2 on each blade using boot from SAN. I have created my service profile and associated it with a blade. The profile has two SAN boot targets pointing at 2 different WWNs corresponding to ports on SPA and SPB. They are configured as a primary and secondary.
When the blade boots I have to manually register the first initiator that connects and assign it to the proper storage group so that my server will continue to boot and install ESXi. During this process I only have one of the two SAN boot targets configured. I also have assigned 4 vHBAs to the profile. After I get the blade set up with ESXi I then go in and add the secondary SAN boot target.
My problem is this....
When I look at the initiators on the VNX I see 5 initiators instead of the 4 I would expect.
Example: I have A-4, A-5, B-4 and B-5 wired on the VNX. I have assigned the SAN boot targets to A-4 and B-4. I would expect to see 4 initiators (2 that point to one of the A-X and 2 that point to the B-X). What I am seeing is 4 initiators that follow this pattern and one initiator that is duplicated and points to A-4 and B-4. Looking at the initiators it seems that the duplicate initiator that points at B-4 is erroneous.
Why am I seeing this happen?
Thanks.

An important detail .  Which version of UCSM?
Also provide your zoning config:
connect nxos a
show zone
exit
connect nxos b
show zone
Thanks,
Robert

Similar Messages

  • FCoE options for Cisco UCS and Compellent SAN

    Hi,
    We have a Dell Compellent SAN storage with iSCSI and FCoE module in pre-production environment.
    It is connected to new Cisco UCS infrastructure (5108 Chassis with 2208IOM + B200 M2 Blades + 6248 Fabric Interconnect) via 10G iSCSI module (FCoE module isn't being used at th is moment).
    I reviewed compatibility matrix on interconnect but Compellent (Dell) SAN is only supported on FI NXOS 1.3(1), 1.4(1) without using 6248 and 2208 IOM which is what we have. I'm sure some of you have similar hardware configuration as ours and I'd like to see if there's any supportive Cisco FC/FCoE deployment option for the Compellent. We're pretty tight on budget at this moment so purchasing couple of Nexus 5K switches or something equipvalent for such a small number of chassis (only only have one) is not a preferred option. If additional hardware acquisition is inevitable, what would be the most cost effective solution to be able to support FCoE implementation?
    Thank you in advance for your help on this.

    Unfortunatly there isn't really one - with direct attach storage there is still the requirement that an upstream MDS/N5k pushes the zoning to it.  Without a MDS to push the zoning the system it's recommended for production.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html#concept_05717B723C2746E1A9F6AB3A3FFA2C72
    Even if you had a MDS/N5K the 6248/2208's wouldn't support the Compellent SAN - see note 9.
    http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/Matrix8.pdf
    That's not to say that it won't work, it's just that we haven't tested it and don't know what it will do and thus TAC cannot troubleshoot SAN errors on the UCS.
    On the plus side iSCSI if setup correctly can be very solid and can give you a great amount of throughput - just make sure to configure the QoS correctly and if you need more throughput then just add some additional links

  • RSPAN Between Cisco UCS and 6500

    Hi,
    I need to SPAN traffic comming one server inside UCS and the destination as my 6500 core. I tried to get some document to check how to configure RPSN between UCS and 6500. Please guide
    Thanks
    Nibin

    You've answered your own question in the first sentence.
    To recap: OS X is licensed only on Apple-branded hardware.  Cisco-branded hardware is not Apple-branded hardware.   Therefore, OS X is not licensed on Cisco-branded hardware.

  • Cisco UCS and OS X

    I know the ELUA says that you can run a vm if it is on apple branded hardware.  I am wondering if Cisco UCS hardware is certified to run either OS X 10.9 or OS X Server.  Can we purchase a volume license of OS X server to do this?  I would like to be able to spin up some virtual macs that would be redundantly replicated between our data centers.
    Any info will be extremly appreciated.
    Thanks

    You've answered your own question in the first sentence.
    To recap: OS X is licensed only on Apple-branded hardware.  Cisco-branded hardware is not Apple-branded hardware.   Therefore, OS X is not licensed on Cisco-branded hardware.

  • Cisco UCS and NetApp MetroCluster

    Hi all,
    Anyone with any thoughts re this:
    Dual site setup with NetApp Fabric MetroCluster (two storage controllers stretched over fiber links)
    Two Nexus 5000 switches at each site, so we have two FC fabrics, stretching both sites (as required for MetroCluster)
    To be introduced: UCS with dual Fabric Interconnect Modules at *each* site
    Are there any references or documentation describing this? I have a slight concern that we will have UCS FIC modules across two sites on the same FC fabric (A & B respectively) & I’m not 100% sure they will behave nicely.
    Thanks,
    Radek

    For anyone interested - got the answer on NetApp forums:
    https://communities.netapp.com/thread/30304#111530

  • Cisco UCS Vmware and HDS

    We about to build a new data center with a Hitachi VSP disk array,  Cisco UCS and Vmware.   I have some information from the Hitachi side but it really says nothing about the UCS. Is there a "best practices" , "configuration guide" for the UCS side of this? 

    see
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/ucs_hds.html
    Cisco Solution for Hitachi Unified Compute Platform Select with VMware vSphere

  • Ask the Expert: Cisco UCS B-Series Latest Version New Features

    Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about the Cisco UCS Manager 2.2(1) release, which delivers several important features and major enhancements in the fabric, compute, and operational areas. Some of these features include fabric scaling, VLANs, VIFs, IGMP groups, network endpoints, unidirectional link detection (UDLD) support, support for virtual machine queue (VMQ), direct connect C-Series to FI without FEX, direct KVM access, and several other features.
    Teclus Dsouza is a customer support engineer from the Server Virtualization team at the Cisco Technical Assistance Center in Bangalore, India. He has over 15 years of total IT experience. He has worked across different technologies and a wide range of data center products. He is an expert in Cisco Nexus 1000V and Cisco UCS products. He has more than 6 years of experience on VMware virtualization products.  
    Chetan Parik is a customer support engineer from the Server Virtualization team at the Cisco Technical Assistance Center in Bangalore, India. He has seven years of total experience. He has worked on a wide range of Cisco data center products such as Cisco UCS and Cisco Nexus 1000V. He also has five years of experience on VMware virtualization products.
    Remember to use the rating system to let Teclus and Chetan know if you have received an adequate response. 
    Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through May 9, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hi Jackson,
    Yes its is possible.    Connect the storage array to the fabric interconnects using two 10GB links per storage processor.  Connect each SP to both fabric interconnects and configure the ports on the fabric interconnect as “Appliance” ports from UCSM
    For more information on how to connect Netapp storage using other protocols like iSCSI or FCOE  please check the url below.
    http://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-6100-series-fabric-interconnects/whitepaper_c11-702584.html
    Regards
    Teclus Dsouza

  • Ask the Expert: Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI

    Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI with Vishal Mehta and Manuel Velasco.
    The current industry trend is to use SAN (FC/FCoE/iSCSI) for booting operating systems instead of using local storage.
    Boot from SAN offers many benefits, including:
    Server without local storage can run cooler and use the extra space for other components.
    Redeployment of servers caused by hardware failures becomes easier with boot from SAN servers.
    SAN storage allows the administrator to use storage more efficiently.
    Boot from SAN offers reliability because the user can access the boot disk through multiple paths, which protects the disk from being a single point of failure.
    Cisco UCS takes away much of the complexity with its service profiles and associated boot policies to make boot from SAN deployment an easy task.
    Vishal Mehta is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco Nexus 5000, Cisco UCS, Cisco Nexus 1000v, and virtualization. He has presented at Cisco Live in Orlando 2013 and will present at Cisco Live Milan 2014 (BRKCOM-3003, BRKDCT-3444, and LABDCT-2333). He holds a master’s degree from Rutgers University in electrical and computer engineering and has CCIE certification (number 37139) in routing and switching and service provider.
    Manuel Velasco is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco UCS, Cisco Nexus 1000v, and virtualization. Manuel holds a master’s degree in electrical engineering from California Polytechnic State University (Cal Poly) and VMware VCP and CCNA certifications.
    Remember to use the rating system to let Vishal and Manuel know if you have received an adequate response. 
    Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through April 25, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hello Evan
    Thank you for asking this question. Most common TAC cases that we have seen on Boot-from-SAN failures are due to misconfiguration.
    So our methodology is to verify configuration and troubleshoot from server to storage switches to storage array.
    Before diving into troubleshooting, make sure there is clear understanding of this topology. This is very vital with any troubleshooting scenario. Know what devices you have and how they are connected, how many paths are connected, Switch/NPV mode and so on.
    Always try to troubleshoot one path at a time and verify that the setup is in complaint with the SW/HW interop matrix tested by Cisco.
    Step 1: Check at server
    a. make sure to have uniform firmware version across all components of UCS
    b. Verify if VSAN is created and FC uplinks are configured correctly. VSANs/FCoE-vlan should be unique per fabric
    c. Verify at service profile level for configuration of vHBAs - vHBA per Fabric should have unique VSAN number
    Note down the WWPN of your vhba. This will be needed in step 2 for zoning on the SAN switch and step 3 for LUN masking on the storage array.
    d. verify if Boot Policy of the service profile is configured to Boot From SAN - the Boot Order and its parameters such as Lun ID and WWN are extremely important
    e. finally at UCS CLI - verify the flogi of vHBAs (for NPV mode, command is (from nxos) – show npv flogi-table)
    Step 2: Check at Storage Switch
    a. Verify the mode (by default UCS is in FC end-host mode, so storage switch has to be in NPIV mode; unless UCS is in FC Switch mode)
    b. Verify the switch port connecting to UCS is UP as an F-Port and is configured for correct VSAN
    c. Check if both the initiator (Server) and the target (Storage) are logged into the fabric switch (command for MDS/N5k - show flogi database vsan X)
    d. Once confirmed that initiator and target devices are logged into the fabric, query the name server to see if they have registered themselves correctly. (command - show fcns database vsan X)
    e. Most important configuration to check on Storage Switch is the zoning
    Zoning is basically access control for our initiator to  targets. Most common design is to configure one zone per initiator and target.
    Zoning will require you to configure a zone, put that zone into your current zonset, then ACTIVATE it. (command - show zoneset active vsan X)
    Step 3: Check at Storage Array
    When the Storage array logs into the SAN fabric, it queries the name server to see which devices it can communicate.
    LUN masking is crucial step on Storage Array which gives particular host (server) access to specific LUN
    Assuming that both the storage and initiator have FLOGI’d into the fabric and the zoning is correct (as per Step 1 & 2)
    Following needs to be verified at Storage Array level
    a. Are the wwpn of the initiators (vhba of the hosts) visible on the storage array?
    b. If above is yes then Is LUN Masking applied?
    c. What LUN number is presented to the host - this is the number that we see in Lun ID on the 'Boot Order' of Step 1
    Below document has details and troubleshooting outputs:
    http://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-b-series-blade-servers/115764-ucs-san-tshoot-00.html
    Hope this answers your question.
    Thanks,
    Vishal 

  • Monitoring for Cisco UCS/Cisco Catalyst/EMC VNX/VMware environment

    hi
    I am not sure whether this is the right place for this post, but I am giving it a shot anyway.
    I am looking for a monitoring solution for a Cisco UCS/Cisco Catalyst/EMC VNX/VMware environment and I cannot seem to find 1 product that does it all.
    Do any of you Guys have experience with a such product?
    thanks...

    I have used PRTG for Cisco Routers/Switch, Vmware  and with Cisco UCS. As for the storage part I'm not sure.
    I recommend prtg because its user friendly and web based management.
    Please Rate.

  • Ask the Expert : Initial Set Up and LAN Connectivity for Cisco UCS Servers

    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about related to the initial setup of UCS C & B Series which include LAN connectivity from the UCS perspective with Cisco subject matter expert Kenny Perez.
    In particularly, Kenny will cover topics such as: ESXi/Windows  installations, RAID configurations (best practices for good performance and configuration), VLAN/Jumbo Frames configuration for B series and C series servers, Pools/Policies/Upgrades/Templates/Troubleshooting Tips for blade and rack servers, Fabric Interconnects configuration, general compatibility of Hardware/Software/drivers amongst other topics
    Kenny Perez is a technical leader in Cisco Technical Assistance Center, where he works in Server Virtualization support team. His main job consists of supporting customers to implement and manage Cisco UCS B series and C series. He has background in computing, networking, and Vmware ESXi and has 3+ years of experience support UCS servers and is VCP certified.
    Remember to use the rating system to let Kenny know if he has given you an adequate response. 
    This event lasts through October 10th, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hi,
    Actually  we have UCS 6248 fabric interconnect - first twelve ports are enabled  and same in Cisco UCS Manager.
    But when more port will be active by expansion module  then UCSM can manage that too or need any other licence  for UCSM too?

  • Cisco UCS components and Heartbleed bug

    I was reading about Cisco products affected by heartbleed vulnerability at following Cisco security advisory
    http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20140409-heartbleed#@ID
    I couldn't find whether below products/components are affected by this vulnerability.. can someone confirm if these products/components are vulnerable to heartbleed?
    Cisco UCS Manager
    Cisco Integrated Management Controller (CIMC)
    Cisco UCS Blade Chassis
    tia

    I agree that phrasing is a bit off, note that the notice is talking about _products_ affected (or not), not particular _components_ of a product. 
    UCS seems to be off the hook. Not affected are: 
    Cisco UCS B-Series (Blade) Servers
    Cisco UCS C-Series (Stand alone Rack) Servers
    Cisco UCS Central
    Cisco UCS Fabric Interconnects
    Cisco UCS Invicta Series Solid State Systems
    CIMC and UCSM would be part of FI or B-or-C-series, etc.

  • Cisco UCS 6248 and Dell EQ 6510x

            We have a Dell EQ 6510x we have in production and we are about to power on a Cisco UCS B series chassis and a pair of 6248UP FIs. I'm planning to connect the 4 6510x 10G ports directly to the 6248 FIs and set them as Applicance Ports.
    My question is would be be better to connect the 6510x Primary controller's two 10G ports directly to FI-A and the standby controller 10G ports directly to FI-B, or stagger them? Stagger meaning Primary Controller one10G to FI-A and one 10G to FI-B then Standby controller one 10G to FI-A and one10G to FI-B. Thanks!

    Hello there,
    In your design always keep in mind that both UCS FI are separate switches, they always will talk each other by the upstream switch. The best pratice is connect anything that have to talk with UCS domain in the upstream switch.
    If there is no option to do so, you can connect through the FIs, using a appliance port. In your case I believe that connect stagger mode is the best option, but I'm not sure, depends how your vnics are configured and if your Dell EQ can do port-channel in active-standby mode.

  • Cisco Unity Connection 8.X and Cisco UCS

    Hi
    We are in a planning phase for Unity Connection 8.X on Cisco UCS C-Series. The Cisco Unified Communications SRND 8.0 states that requires reserving one physical core per physical server.
    what does it really mean?

    See sample depiction below of applications and physical core usage on a server with 2 CPUs and 8 total physical cores. In white is the reservation of one physical core.
    Regards.

  • Nexus 1000v UCS Manager and Cisco UCS M81KR

    Hello everyone
    I am confused about how works the integration between N1K and UCS Manager:
    First question:
    If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
    I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
    Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
    Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
    I tried to read differnt documents, but I did not understand.
    Thanks                 

    This document may help...
    Best Practices in Deploying Cisco Nexus 1000V Series Switches on Cisco UCS B and C Series Cisco UCS Manager Servers
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9902/white_paper_c11-558242.html
    If two VMs on different ESXi and different VEM but in the same  VLAN,would like to talk each other, the data flow between them is  managed from the upstream switch( in this case UCS Fabric Inteconnect),  isn'it?
    -Yes.  Each ESX host with the VEM will have one or more dedicated NICs for the VEMs to communicate with the upstream network.  These would be your 'type ethernet' port-profiles.  The ustream network would need to bridge the vlan between the two physicall nics.
    Second question: With the configuration above, if I include in the vNIC  profile the vlan 100 (not as native vlan) only, the two VMs can not ping  each other. Instead if I include in the vNIC profile only the defaul  vlan(I think it is the vlan 1) as native vlan evereything works fine.  WHY????
    -  The N1K port profiles are switchport access making them untagged.  This would be the native vlan in ucs.  If there is no native vlan in the UCS configuration, we do not have the upstream networking bridging the vlan.
    Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
    -  All ports on the UCS are effectively trunks and you can define what vlans are allowed on the trunk as well as what vlan is passed natively or untagged.  In N1K, you will want to leave your vEthernet port profiles as 'switchport mode access'.  For your Ethernet profiles, you will want them to be 'switchport mode trunk'.  Use an used used vlan as the native vlan.  All production vlans will be passed from N1K to UCS as tagged vlans.
    Thank You,
    Dan Laden
    PDI Helpdesk
    http://www.cisco.com/go/pdihelpdesk

  • Error Compilation MIBs Supported for Cisco UCS C-series software release 1.4(3) and later releases on IBM Director 6.3.2

    Hi,
    I have an IBM director 6.3.2 on a Windows Server 2008R2
    I try to install the MIB for manage Cisco UCS C-460 server.
    I downloaded the mib on the cisco ftp.
    the files extension was my. I cahgne it to .mib. For the moment I success to import some ones.
    But when I try to install Cisco-Unified-Computing-TC-MIB, I have got the error in the join file.
    Ho can I fix this issue...

    Hi,
    I have an IBM director 6.3.2 on a Windows Server 2008R2
    I try to install the MIB for manage Cisco UCS C-460 server.
    I downloaded the mib on the cisco ftp.
    the files extension was my. I cahgne it to .mib. For the moment I success to import some ones.
    But when I try to install Cisco-Unified-Computing-TC-MIB, I have got the error in the join file.
    Ho can I fix this issue...

Maybe you are looking for

  • How to implement the Export to Excel funtionality in VC like in Webdynpro

    Hi I have requirement to display the BAR charts, Pie charts ,Line graphs based on the data retreiving from the R/3 thorgh VC. I hope it is possible . i have requirement like exporting the data whichis pulled from the R3 to display those charts, this

  • Send a message to phone.

    I am writing a Report, that functonality requires to send a message to phone. please help me in this regard....

  • Why does AI CC 2014 "Welcome Window" contain tutorials demonstrating AI CC not 2014?

    This is REALLY confusing. I am relieved to see "smooth tool toggle" has been returned as an option for the Pencil tool in CC 2014, but the "Rebuilt Pencil Tool" video within "Welcome>New Features" is showing an old version that does NOT contain this

  • Why do my sounds not work on occasion - device and audio settings appear ok

    At times, the sound does not work.  The phone is on and not muted and a specific sound is selected for each function.  Most noticeable is no sound when a call or text comes through. Anyone have an idea?  Thanks !

  • Imac update

    Hello. I have an imac, os x 10.3.9 1 ghz G4, and 512 MB. I would like to know the benefits of updating. Does it help the computer run better? I use my computer mostly for business, all the rest I just use the basics, like with I photo and I tunes. Wh