Cisco UCS Management IP Address assigned twice?

I have a blade chassis with 8 servers, and a pool of management addresses assigned to a service profile template.  All 8 servers are built from this template.  There are 8 addresses in the pool.
I am finding that 4 servers in I have exhausted all 8 addresses from the management pool.  Upon further investigation, it looks like all servers have taken 2 addresses from this pool.  One address is the address assigned to org-root/service-profile-name/ipv4-pooled-addr.  Another address (same server) is assigned to sys/chassis-number/blade-number/mgmt/ipv4-pooled-addr.
What am I doing wrong?

It is my understanding that this is the correct / default behaviour. When you created a mgmt pool, physical hardware automatically picks up an address after discovery. When you create a template, you do not necessarily need to assign the pool to the template as when you accociate a profile with hardware then you can access the KVM to the profile via the address assigned to the hardware. The upside of assigning a pool to the template / profile is the fact that that address will always live with the profile (server) as opposed to an address on the hardware which could have different profiles assigned at different times.  So, if you assign to the template / profile you will use 2 x the addresses from the pool.

Similar Messages

  • Monitoring Cisco UCS Manager via HP System Information Manager 7.1 (SIM)

    I am working with a customer to configure HP System Information Manager 7.1 (SIM) to monitor their Cisco UCS Manager.
    The customer is looking to monitor the following:
    - CPU Utilization on manager, blades, servers, etc...
    - Memory utilization
    - Network utilization
    - System inventory
    Alerting is needed for the following:
    - Hardware failures: memory, power supply, drive, etc...
    - Predictive failures
    - Alert messages
    I have the list of all the MIBs provided by Cisco but an having the following issues while loading them into HP SIM.
    While loading MIB "CISCO-UNIFIED-COMPUTING-TC-MIB" I get the following error message:
    Line 128: Error defining object: expected a label, found reserved symbol {
    Line in MIB: SYNTAX Gauge32 {
    Guage32 is imported from SNMPv2-SMI MIB
    To get past this error I found a version of the MIB that removes all the textual conventions that where causing errors.  I have attached the fixed MIB file to this discussion. With the fixed version of the MIB installed in SIM everything compiles and installs except the following two MIBS. CISCO-UNIFIED-COMPUTING-NOTIFS-MIBCISCO-UNIFIED-COMPUTING-CONFORM-MIB Questions:
    1. Is there any way to get the CISCO-UNIFIED-COMPUTING-TC-MIB MIB to install correctly into HP SIM?
    2. Is my MIB load order setup correctly?
    3. Has anyone had success getting HP SIM to monitor and alert for Cisco UCS manager?
    MIB Load Order:
    SNMPv2-SMI
    SNMPv2-TC
    SNMP-FRAMEWORK-MIB
    RFC1213-MIB
    IF-MIB
    CISCO-SMI
    CISCO-ST-TC
    ENTITY-MIB
    INET-ADDRESS-MIB
    CISCO-UNIFIED-COMPUTING-MIB
    CISCO-UNIFIED-COMPUTING-TC-MIB
    CISCO-UNIFIED-COMPUTING-FAULT-MIB
    CISCO-UNIFIED-COMPUTING-NOTIFS-MIB
    CISCO-UNIFIED-COMPUTING-AAA-MIB
    CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB
    CISCO-UNIFIED-COMPUTING-BIOS-MIB
    CISCO-UNIFIED-COMPUTING-BMC-MIB
    CISCO-UNIFIED-COMPUTING-CALLHOME-MIB
    CISCO-UNIFIED-COMPUTING-CAPABILITY-MIB
    CISCO-UNIFIED-COMPUTING-COMM-MIB
    CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
    CISCO-UNIFIED-COMPUTING-CONFORM-MIB
    CISCO-UNIFIED-COMPUTING-DCX-MIB
    CISCO-UNIFIED-COMPUTING-DHCP-MIB
    CISCO-UNIFIED-COMPUTING-DIAG-MIB
    CISCO-UNIFIED-COMPUTING-DPSEC-MIB
    CISCO-UNIFIED-COMPUTING-EPQOS-MIB
    CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
    CISCO-UNIFIED-COMPUTING-ETHER-MIB
    CISCO-UNIFIED-COMPUTING-EVENT-MIB
    CISCO-UNIFIED-COMPUTING-EXTMGMT-MIB
    CISCO-UNIFIED-COMPUTING-EXTVMM-MIB
    CISCO-UNIFIED-COMPUTING-FABRIC-MIB
    CISCO-UNIFIED-COMPUTING-FC-MIB
    CISCO-UNIFIED-COMPUTING-FCPOOL-MIB
    CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
    CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
    CISCO-UNIFIED-COMPUTING-HOSTIMG-MIB
    CISCO-UNIFIED-COMPUTING-IMGPROV-MIB
    CISCO-UNIFIED-COMPUTING-IMGSEC-MIB
    CISCO-UNIFIED-COMPUTING-IPPOOL-MIB
    CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB
    CISCO-UNIFIED-COMPUTING-ISCSI-MIB
    CISCO-UNIFIED-COMPUTING-LICENSE-MIB
    CISCO-UNIFIED-COMPUTING-LLDP-MIB
    CISCO-UNIFIED-COMPUTING-LSBOOT-MIB
    CISCO-UNIFIED-COMPUTING-LSMAINT-MIB
    CISCO-UNIFIED-COMPUTING-LS-MIB
    CISCO-UNIFIED-COMPUTING-MACPOOL-MIB
    CISCO-UNIFIED-COMPUTING-MAPPINGS-MIB
    CISCO-UNIFIED-COMPUTING-MEMORY-MIB
    CISCO-UNIFIED-COMPUTING-MGMT-MIB
    CISCO-UNIFIED-COMPUTING-NETWORK-MIB
    CISCO-UNIFIED-COMPUTING-NWCTRL-MIB
    CISCO-UNIFIED-COMPUTING-ORG-MIB
    CISCO-UNIFIED-COMPUTING-OS-MIB
    CISCO-UNIFIED-COMPUTING-PCI-MIB
    CISCO-UNIFIED-COMPUTING-PKI-MIB
    CISCO-UNIFIED-COMPUTING-PORT-MIB
    CISCO-UNIFIED-COMPUTING-POWER-MIB
    CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
    CISCO-UNIFIED-COMPUTING-PROC-MIB
    CISCO-UNIFIED-COMPUTING-QOSCLASS-MIB
    CISCO-UNIFIED-COMPUTING-SOL-MIB
    CISCO-UNIFIED-COMPUTING-STATS-MIB
    CISCO-UNIFIED-COMPUTING-STORAGE-MIB
    CISCO-UNIFIED-COMPUTING-SW-MIB
    CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB
    CISCO-UNIFIED-COMPUTING-SYSFILE-MIB
    CISCO-UNIFIED-COMPUTING-TOP-MIB
    CISCO-UNIFIED-COMPUTING-TRIG-MIB
    CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB
    CISCO-UNIFIED-COMPUTING-VM-MIB
    CISCO-UNIFIED-COMPUTING-VNIC-MIB
    References:
    ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-manager-supportlist.html#_Toc303691433
    http://www.hp.com/wwsolutions/misc/hpsim-helpfiles/simsnmp.pdf

    Please post "debug ccsip messages".
    Based on your debug you are getting "Cause No. 38 - network out of order."
    You may want to bind SIP to an interface that the IP address is defined which Lync points to.
    Chris

  • Cisco UCS Management Pack Error

    Hello,
    I'm trying to configure the UCS Management pack for SCOM but when I try to configure in the Authoring pane, the IP + Username password, I have this error:
    Data at the root level is invalid. Line 1, position 1.
    I'm using the last version of the management pack, 3.0.2.
    Any idea?
    Thank you.
    Regards,
    Florent

    Hello,
    Check this below links
    Release Notes for Cisco UCS Manager Management Pack for Microsoft SCOM MP 2.6.1:
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/msft_tools/scom/scom_2.6/scom_2.6_release_notes/scom_releasenotes_2_6.html
    User Guide for Cisco UCS Manager Management Pack for Microsoft SCOM MP 2.6.1:
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/msft_tools/scom/scom_2.6/scom_2.6_user_guide/scom_2_6_userguide.html
    https://communities.cisco.com/community/technology/datacenter/ucs_management/cisco_ucs_developed_integrations/blog/2013/10/18/cisco-ucs-manager-management-pack-for-microsoft-scom-version-261
    Regards
    keshav

  • How to manage IP address assignment for laptops?

    Dear All,
    I'm looking for an efficient way to manage IP address assignment for laptops.
    I have a DHCP server with reservation for all my devices.
    Laptops usually have 2 NICs: LAN and WiFi card.
    So, how can I manage the IP assignment for these devices?
    If I make a DHCP reservetion with two different IP addresses, I can have problems with DNS round-robin.
    Should I enable the DNS secure dynamic update for domain members and then reserve two different IP addresses on DHCP?
    I don't want that user needs to manually change their NIC configuration.
    What you suggest?
    Thanks

    The best way to manage it would be to "not" manage it.  DHCP by definition is supposed to be "dynamic".  DHCP Reservations are great for a few devices that live under "special circumstances" but you never want to set Reservations for everything,...if
    you do that then just don't have DHCP to start with and statically assign everything.
    The combination of DHCP with dynamically updated DNS in AD means you never have to know or ever care what the IP# is.  Everything is referred to by it's hostname.
    Some things to keep in mind:
    Every interfaces has a different MAC,...meaning the Laptops have two MACs. Therefore it is impossible to reserve the same IP# for both. So they end up with a different IP# depending on which Nic they use.  Running two laptop nics on the same LAN at
    the same time is always bad.  Either always use the wireless,...or always turn off the wireless nic when laptops are local within your facility and can use the physical nic.   In other words pick one,...or the other,...never allow both to work
    at the same time.  This is a responsibility and education issue of the user,...you can't do this for them.
    User can not change their own network IP Specs unless they are Local Administrators on their machines,...and they should never be allowed to be Local Administrators.

  • Cisco UCS Management Pack for System Center Operations Manager 2007 R2 Login Error

    I have Cisco UCS 1.4 (3q) and just installed the MP v2.1 for Cisco UCS, however when I click on the "Management Pack Events" alert view in the SCOM console, there are error for event number 19900.  The description of the error is as follows:
    Description:
    CISCO UCS R2 MP (https://10.x.x.x/nuova) [CISCO.UCS.R2.Proxy.LoadCache.ProbeAction.vbs] : CISCO UCS Login Error: Authentication failed (Code: 551)
    I noticed that it's looking for the /nuova directory, but in order to login to our UCS environment, we usually just go to the IP address - so I'm wondering if that has something to do with it?  I've verified that when going directly to the IP from Internet Explorer I can login using the opsmgr credentials we specifically created for this account.  I've also gone through the process of creating a run-as account on the SCOM side and associated it with the correct profiles.
    Any help is greatly appreciated.

    Troubleshooting has found out its user error, wrong password configured.

  • Cisco UCS Manager not discovering C240 server

    Hello, Cisco community!
    Currenlty UCS manager shows two Fabric Interconnects, and two Fabric Extenders, but for some reason my server isn't showing up
    Here is the birds eye view:
    I have my C240 connected with two 10GbE twinax cables, each going to one fabric extender. (2 FEX total)
    I have two 10GbE twinax cables connected from the fiber module of each FEX to each Fabric interconnects. (2 FI total)
    The fabric interconnect ports L1 and L2 ports are connected to their corresponding ports. So their connected to each other.
    I run 'show cluster extended-state' on the primary FI and this is what i get:
    FI-A# show cluster extended-state
    Cluster Id: 0xebaad0e28ded11e3-0x86d4002a6a153d84
    Start time: Wed Feb  5 16:07:44 2014
    Last election time: Wed Feb  5 16:23:26 2014
    A: UP, PRIMARY
    B: UP, SUBORDINATE
    A: memb state UP, lead state PRIMARY, mgmt services state: UP
    B: memb state UP, lead state SUBORDINATE, mgmt services state: UP
       heartbeat state PRIMARY_OK
    INTERNAL NETWORK INTERFACES:
    eth1, UP
    eth2, UP
    HA NOT READY
    No device connected to this Fabric Interconnect
    After configuring the server-side ports on each FI, the server still doesn't show up
    Any idea are highly appreciated!!
    -Alex

    It's good to know that the Fabric Interconnects don't need upstream connectivity, so we can scratch that from our list of possible issues.
    For clarity, here are the important firware versions:
    CMIC - 1.5(3), cisco recommends a minimum of 1.4(6)
    BIOS - 1.5.1c, cisco recommends a minumum of 1.4.7a
    vNIC - 2.1(1c), cisco recommends a minumum of 2.1(0.367e)
    So, we can cross out firware mis-matches from the list.
    wdey,
    I tried going trough UCS Manager and looking where i could configure the out-of-band IP management pool, but I can't find the right place to do that. Here is a screen shot of the VLAN tab of my UCS Manager.
    Could you eleborate more on the process of how to do this? This might fix the issue.
    Also, I noticed that in the BIOs setting screen, under Advanced -> LOM and PCIe Slots configuration -> PCIe Slot ID: 2(VIC 1225) it says Option ROM Status Not Loaded. Do you think this might have something to do with server discovery?
    Thanks alot for the help guys It's really much apprecaited.
    -Alex

  • Cisco UCS Managment interface

    Hi Dear
    Which is the function of the management interface of a Cisco UCS server? Only monitoring ?
    Best Regards

    Hi,
    The management interface present in the Cisco UCS C-Series is a out-of-band interface that provides to you access to Cisco Integrated Management Controller (CIMC) where you can perform all management/monitoring tasks related the hardware set.
    You can find more information about the CIMC in this link:
    http://www.cisco.com/c/en/us/support/servers-unified-computing/ucs-c-series-integrated-management-controller/tsd-products-support-series-home.html
    Regards,
    Richard

  • Nexus 1000v UCS Manager and Cisco UCS M81KR

    Hello everyone
    I am confused about how works the integration between N1K and UCS Manager:
    First question:
    If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
    I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
    Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
    Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
    I tried to read differnt documents, but I did not understand.
    Thanks                 

    This document may help...
    Best Practices in Deploying Cisco Nexus 1000V Series Switches on Cisco UCS B and C Series Cisco UCS Manager Servers
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9902/white_paper_c11-558242.html
    If two VMs on different ESXi and different VEM but in the same  VLAN,would like to talk each other, the data flow between them is  managed from the upstream switch( in this case UCS Fabric Inteconnect),  isn'it?
    -Yes.  Each ESX host with the VEM will have one or more dedicated NICs for the VEMs to communicate with the upstream network.  These would be your 'type ethernet' port-profiles.  The ustream network would need to bridge the vlan between the two physicall nics.
    Second question: With the configuration above, if I include in the vNIC  profile the vlan 100 (not as native vlan) only, the two VMs can not ping  each other. Instead if I include in the vNIC profile only the defaul  vlan(I think it is the vlan 1) as native vlan evereything works fine.  WHY????
    -  The N1K port profiles are switchport access making them untagged.  This would be the native vlan in ucs.  If there is no native vlan in the UCS configuration, we do not have the upstream networking bridging the vlan.
    Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
    -  All ports on the UCS are effectively trunks and you can define what vlans are allowed on the trunk as well as what vlan is passed natively or untagged.  In N1K, you will want to leave your vEthernet port profiles as 'switchport mode access'.  For your Ethernet profiles, you will want them to be 'switchport mode trunk'.  Use an used used vlan as the native vlan.  All production vlans will be passed from N1K to UCS as tagged vlans.
    Thank You,
    Dan Laden
    PDI Helpdesk
    http://www.cisco.com/go/pdihelpdesk

  • How to move a standalone Cisco C series to UCS managed service profile without losing data?

    Hi,
    We currently have a standalone cisco C series server with Windows 2012 installed on the local disks.  We need to move this server to Cisco UCS managed with a service profile but cannot lose the existing data and OS boot method.
    Does anyone know how to do this?
    Thanks

    Hi Adrian,
    To be able to accomplish this set the local disk policy to "Any Configuration"  this way UCSM  won't overwrite the current raid configuration on the server. 
    See link below
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-1/b_UCSM_GUI_Configuration_Guide_2_1/b_UCSM_GUI_Configuration_Guide_2_1_chapter_011110.html#task_897FABF194524BDF8C0EF72E755972F0
    Let it me know if this helps

  • Cisco UCS network uplink on aggregation layer

    Hello Cisco Community,
    we are using our UCS (Version 2.21d) for ESX Hosts. Each host has 3 vnics as follows:
    vnic 0 = VLAN 10 --> Fabric A, Failover Fabric B
    vnic 1 = VLAN 20 --> Fabric B, Failover Fabric A
    vnic 2 = VLAN 100 --> Fabric A, Failover Fabric B
    Actually UCS is connected to the Access Layer (Catalyst 6509) and we are migrating to Nexus (vPC). As you know, Cisco UCS Fabric Interconnects can handle layer2 traffic itself. So we are planning to connect our UCS Fabric Interconnects directly to our new l3 nexus switch.
    Does anyone have connect the UCS directly to l3? Do we have to pay attention to something? Are there some recommendations?
    thanks in advance
    best regards
    /Danny

    we are using ESXi 5.5 with dvswitche (distributed vswitch). In our cisco ucs powerworkshop, we discuss pros and contras of hard- and softwarefailover and we commit to use hardwarefailover. It is very fast and we have no problems actually.
    This is a neverending and misunderstood story: your design should provide load balancing AND failover. Hardware failover only gives you the latter.In your design, you just use one fabric per Vlan, what a waste !
    And think about the situation of a failover on a ESXi host with 200 VM's; one has to send out at least 200 GARP messages, and this is load on the FI CPU. Most likely dozens or more ESXi server are impacted......
    Cisco best practise: if you use softswitch, let it do the loadbalancing and failover, don't use hardware failover.
    see attachment (the paper is not up to date,
    For ESX Server running vSwitch/DVS/Nexus 1000v and using Cisco UCS Manager Version 1.3 and below, it is recommended that fabric failover not be enabled, as that will require a chatty server for predictable failover. Instead, create regular vNICs and let the soft switch send
    gARPs for VMs. vNICs should be assigned in pairs (Fabric A and B) so that both fabrics are utilized.
    Cisco UCS version 1.4 has introduced the Fabric Sync feature, which enhances the fabric failover functionality for hypervisors as gARPs for VMs are sent out by the standby FI on failover. It does not necessarily reduce the number of vNICs as load sharing among the fabric is highly recommended. Also recommended is to keep the vNICs with fabric failover disabled, avoiding the use of the Fabric Sync feature in 1.4 for ESX based soft switches for quicker failover.

  • CIMC Access After Integrating C Series with UCS Manager

    My question relates to the following language:
    This guide contains information and procedures for installing Cisco UCS C200, C210 and C250 servers for integration with Cisco UCS Manager release 1.4 or 2.0.1.
    Cisco UCS C-Series Rack-Mount Servers are managed by the built-in standalone software, Cisco Integrated Management Controller (CIMC) . When a C-Series Rack-Mount Serveris integrated with Cisco UCS Manager, the CIMC does not manage the server anymore. Instead it is managed with the Cisco UCS Manager software. You will manage the server using the Cisco UCS Manager GUI or Cisco UCS Manager CLI.
    Does this mean that you literally are unable to web to the CIMC GUI?  Or does it mean that although you can still access the CIMC, the management of the C Series is recommended to be performed via the UCS Manager?
    Are they mutually exclusive?
    Thanks,
    Amir

    Just saw this:
    These UCSM mode settings enable DHCP, Active-Active NIC redundancy, and Shared LOM NIC mode, which enables CIMC control through the 1-Gb LOM ports, rather than the management port. Any static IP addresses and the management port are disabled, so you lose connection with the CIMC.
    So it appears that they are mutually exclusive.

  • SNMP Polling from UCS Manager 1.4

    I am having trouble with SNMP Polling from UCS Manager 1.4(1j).
    I seem to only get SNMP data from Nexus such as those described in (http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/mib/reference/NX5000_MIBRef.html) I don't see any OIDs corresponding to those mentioned specifically for UCS listed in (ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-manager-supportlist.html).
    Documentation on the cisco web site said that UCS Manager 1.4(1) and above will have MIBS such as CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB available.
    Is there a separate IP addresses I should poll for these or any specific things that need to be set up?
    I am not sure how we can gain access to the UCS related MIB objects exactly. The description on SNMP enable for UCS Manager is very brief (http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/1.4/UCSM_GUI_Configuration_Guide_1_4_chapter6.html#task_2054446421216050764)
    It only described the community string set up under UCS Manager ->Admin->Communication Management -> Communication Services, bu didn’t really say anything about which IP addresses from the Management Interfaces should be used to get them.
    Has anyone successfully polled data from say the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB and be able to help?
    Thanks in advance.

    Yes indeed.
    I learnt about the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB and the other Cisco UCS Manager MIB Support list by selecting UCS Manager under the Unified Computing drop down on this http page you quoted.
    (http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/mib/reference/UCS_MIBRef.html)
    Is there anything specific from those docs you are referring to that would make it such that we get the Nexus MIBs rather than ones under UCS Manager?
    The two IP addresses for Fabric Interconnect A and B under Management Interface only give us info from MIBs listed under the Nexus documentation only. Nothing fir say 1.3.6.1.4.1.9.9.719.1.15.
    No SNMP data form the virtual IP address.
    Not sure where data under 1.3.6.1.4.1.9.9.719.1.15 would be accessible

  • Ask the Expert: Cisco UCS B-Series Latest Version New Features

    Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about the Cisco UCS Manager 2.2(1) release, which delivers several important features and major enhancements in the fabric, compute, and operational areas. Some of these features include fabric scaling, VLANs, VIFs, IGMP groups, network endpoints, unidirectional link detection (UDLD) support, support for virtual machine queue (VMQ), direct connect C-Series to FI without FEX, direct KVM access, and several other features.
    Teclus Dsouza is a customer support engineer from the Server Virtualization team at the Cisco Technical Assistance Center in Bangalore, India. He has over 15 years of total IT experience. He has worked across different technologies and a wide range of data center products. He is an expert in Cisco Nexus 1000V and Cisco UCS products. He has more than 6 years of experience on VMware virtualization products.  
    Chetan Parik is a customer support engineer from the Server Virtualization team at the Cisco Technical Assistance Center in Bangalore, India. He has seven years of total experience. He has worked on a wide range of Cisco data center products such as Cisco UCS and Cisco Nexus 1000V. He also has five years of experience on VMware virtualization products.
    Remember to use the rating system to let Teclus and Chetan know if you have received an adequate response. 
    Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through May 9, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hi Jackson,
    Yes its is possible.    Connect the storage array to the fabric interconnects using two 10GB links per storage processor.  Connect each SP to both fabric interconnects and configure the ports on the fabric interconnect as “Appliance” ports from UCSM
    For more information on how to connect Netapp storage using other protocols like iSCSI or FCOE  please check the url below.
    http://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-6100-series-fabric-interconnects/whitepaper_c11-702584.html
    Regards
    Teclus Dsouza

  • Cisco UCS with FEX system Component requirements

    Hi ,
    I am looking for quick suggestion for required components to have a VMware vSAN implemented using FEX system with maximum Fabric trough put. Ideally a configuration for without multipath using single Fabric switch and later on to be able to upgrade to Multipath fabric.
    We are in great rush to provide POC concept and was looking if you folks can suggest me on this. If need be you want to talk to me more in detail I can available.
    Appreciate your help here.
    Who can I reach to able to pull up build and quote the configurations for implementing complete UCS solution.
    Are these below components absolutely required ?
    2 x Nexus 2232PP 10GE Fabric Extenders
    The Cisco Nexus 2232PP 10GE provides 32 x 10Gb loss-less low latency Ethernet and Fiber Channel Over Ethernet (FCoE) Small Form-Factor Pluggable Plus (SFP+) server ports and eight 10 Gb Ethernet and FCoE SFP+ uplink ports in a compact 1 rack unit (1RU) form factor. They enable Seamless inclusion of UCS rack servers into UCS Manager domain with UCS blade servers when connected to the UCS 6200 Fabric Interconnects, providing converged LAN, SAN, and management connectivity.
    We currently have these below servers :
    2 x  UCSC-BASE-M2-C460
            524 GB RAM
            No SSDs
            No VIC Card
            4 x SAS 1 TB Drives
            1 x L1 Intel 1 Gbps Ethernet Adapter
            1 x L2 10Gbps Ethernet Adapter
            1 x LSI Mega RAID SAS 9240-8i (no RAID 5 support, Need a card that supports RAID5)
    1 x  UCSC-C240-M3L
            132 GB RAM
            30 TB SAS HDD
            1 x VIC Card
            1 x Intel I350 Gigabit Ethernet Card with 4 ports
            1 x LSI Mega RAID SAS 9240-8i (no RAID 5 support, Need a card that supports RAID5)
    1 x 5548UP Nexus Switch ( Will I be able to use this switch in place of Nexus 2232PP 10GE Fabric Extenders to achieve complete UCS solution)

    Cisco UCS Manager 2.2 supports an option to connect the C-Series Rack-Mount Server directly to the Fabric Interconnects. You do not need the Fabric Extenders. This option enables Cisco UCS Manager to manage the C-Series Rack-Mount Servers using a single cable for both management traffic and data traffic.
    If you need high performance low latency (storage, for VMware VSAN), direct connection to UCS Fabric Interconnect and/or N5k is recommended.

  • Ask the Expert : Initial Set Up and LAN Connectivity for Cisco UCS Servers

    Welcome to the Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about related to the initial setup of UCS C & B Series which include LAN connectivity from the UCS perspective with Cisco subject matter expert Kenny Perez.
    In particularly, Kenny will cover topics such as: ESXi/Windows  installations, RAID configurations (best practices for good performance and configuration), VLAN/Jumbo Frames configuration for B series and C series servers, Pools/Policies/Upgrades/Templates/Troubleshooting Tips for blade and rack servers, Fabric Interconnects configuration, general compatibility of Hardware/Software/drivers amongst other topics
    Kenny Perez is a technical leader in Cisco Technical Assistance Center, where he works in Server Virtualization support team. His main job consists of supporting customers to implement and manage Cisco UCS B series and C series. He has background in computing, networking, and Vmware ESXi and has 3+ years of experience support UCS servers and is VCP certified.
    Remember to use the rating system to let Kenny know if he has given you an adequate response. 
    This event lasts through October 10th, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hi,
    Actually  we have UCS 6248 fabric interconnect - first twelve ports are enabled  and same in Cisco UCS Manager.
    But when more port will be active by expansion module  then UCSM can manage that too or need any other licence  for UCSM too?

Maybe you are looking for