Cisco UCS PSU issues - CLI commands?

I have a few C200s that are showing one power supoply as "dead" put they are present in the inventory. Currently my power policies are still the default and I am wondering how to tell or see a log or graph of power coming into the PSU.
Also is there a way to modify the power state via CLI?

Hello Eddie,
What is the version of CIMC ? Do you notice any fault logged for it ? What is the LED status of those PSUs ?
The stats can be viewed via CLI / GUI but it does not provide output over the time in a graph format.
In GUI, PSU information and stats are availabe under
Server > Inventory > Power Supplies
Server > Power Policies
Please refer following doc for related CLI commands
http://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/cli/config/guide/1.4.1/Cisco_UCS_C-Series_CLI_Configuration_Guide_141_chapter3.html
Padma

Similar Messages

  • Cisco UCS RAID SAS 2008M-8i Mezzanine Card Performance?

    I recently purchased a UCS C220 bundle, which includes a Cisco UCS RAID SAS 2008M-8i Mezzanine Card.  I'm planning on deploying this as a standalone server running XenServer 6.2 in the near future.
    I'm happy with the unit and testing is good, but for one aspect.  The disk IO throughput on it seems to be far short of what I expected.  I have a desktop PC with an Intel DZ77GA-70K motherboard as a lab spare, and the disk IO I can achieve from that server with the same disks exceeds what the C220 seems to be able to achieve, on a consistent repeatable basis.
    The testing I am doing is based around two benchmarks:
    1. A 400G file copy between the two machines, over the network back-to-back to note the maximum sustained throughput, and
    2. A mix of runs with 'sysbench' to mix of tests of local IO, of sequential and random reads and writes, with the command: "sysbench --test=fileio --file-total-size=150G --file-test-mode=seqrd --init-rng=on --max-time=300 --max-requests=0 run"
    For #1, I run a copy to/from an HP MicroServer Gen8, which has 12TB of disk space on it in a Linux RAID0 configuration (4x3TB Seagate drives).  If I copy files to or from this HP Server to the Intel DZ77GA-70K I am able to easily saturate the 1G network, achieving a sustained 960MBit/s for an hour or more at a time.  If I then take the exact same SATA disks from the DZ77GA-70K, connect these into the UCS box and do the exact same network copy with the exact same OS, I'm only about to get around ~400-500MBit/sec of sustained throughput.
    For #2, the test results of which are entirely local to the C220, come in around 105-110 MByte/sec on a sequential read, which drops to around 2 MByte/sec on a random read or write test.  No surprise of the enormous drop - because random reads/writes are a pretty tough IO load, but I would expect sequential reading should be much better.  I can get consistent sysbench seqrd results from the MicroServer of around 300 MByte/sec, for example.
    I can consistently replicate this with Redhat 6.5, as well as Gentoo (running the latest linux kernel) as well as from a Xen 6.2SP1 Hypervisor install on the C220 (tested from the Dom0 domain itself, as well as a Linux guest) all 64 bit.  Jumbo frames are enabled end-to-end also, and CPU is not bottlenecking.  Latest firmware is installed on all components.  The ucs-cxxx-drivers.1.5.4a.iso image states that for the Redhat and Xen systems, that the required drivers are included in the OS, so I don't need to worry about installing them separately.  Presumably the Gentoo system has even newer drivers again because it has a very new kernel, but alas the throughputs are the same on all of those systems.
    I have tried with SATA as well as a SAS drive, and the test results are also practically the same.  All disks in all servers are Seagate 6.0 Gb/s units, and none of the servers are swapping to disk at any stage.
    I am happy with network IO - I can completely saturate the 1G ports easily, and I'm convinced that's not a part of the problem here.
    What could cause this sort of performance?  Storage card logs in CIMC don't indicate anything is wrong and none of the OS's are indicating issues of any sort, but it certainly does seem something isn't right in that I'm getting significantly superior performance from a desktop motherboard and the MicroServer, than an enterprise grade server, when testing with the exact same hard drives.
    Questions:
    - Is the 2008M-8i card considered a low-end RAID card or should I be getting reasonable throughput from it?  I was anticipating performance at least as good as a desktop motherboard, but this doesn't seem to be the case.  The RAID card as a component is more expensive than an entire MicroServer or Intel Motherboard so it should run much better, yes?
    - What sort of performance should I expect out of this card on a single sequential read or write?
    - Can this RAID card run drives just as JBOD's or do all disks have to be initialised in an array (even if just a RAID0 array with 1 disk)?  It seems if they are added to the server they do not show up to any OS until they are initialised as part of an array, although I haven't delved into the BIOS settings of the card itself (only from CIMC so far).
    - I recall seeing something about best practice of having two virtual drives on these cards, what is the impact in running more, given the card certainly allows more to be created (I currently have 4 while I am testing)
    -  I noticed on Cacti graphs while rebuilding a RAID1 array that the CPU ran hotter while the array was being rebuilt, and cooled down once the rebuild had completed, which indicates the rebuild was using up CPU on the host hardware.  Should this not have been entirely transparent to the system if the RAID activity is offloaded to this card, or is an increase in CPU to be expected?
    I'm very keen to find out others experiences of this card, what people have done to get good throughput out of it, or if I should go back to a whitebox server with an Intel board   :-)
    Thanks,
    Reuben

    Hello Reuben,
    I reached out to colleagues who are more knowledge on this topic and here is their response.
    - Is the 2008M-8i card considered a  low-end RAID card or should I be getting reasonable throughput from  it?  I was anticipating performance at least as good as a desktop  motherboard, but this doesn't seem to be the case.   The RAID card as a component is more expensive than an entire  MicroServer or Intel Motherboard so it should run much better, yes? -
    2008M-8i card is a entry/value card with an  expected performance which is better than a software RAID. This card  doesn’t utilise memory in a standard RAID 0/1 configuration.
    - What sort of performance should I expect out of this card on a single sequential read or write? - We should expect around 1GB sequential read (refer link http://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/unified-computing/whitepaper_c11-728200.html)
    - Can this RAID card run drives  just as JBOD's or do all disks have to be initialised in an array (even  if just a RAID0 array with 1 disk)?  It seems if they are added to the  server they do not show up to any OS until they  are initialised as part of an array, although I haven't delved into the  BIOS settings of the card itself (only from CIMC so far). -
    This card can be used in JBOD mode. To enable JBOD mode you need to use MegaCLI commands.  This option is not present as a default  configuration.
    Please note: Once we enable the JBOD mode – it  cannot be reverted back to the default RAID mode setting.
    - I recall seeing something about  best practice of having two virtual drives on these cards, what is the  impact in running more, given the card certainly allows more to be  created (I currently have 4 while I am testing)  -
    This doesn’t apply for this card as it  does not have any cache. Can you please point us  to the document about best practice of having two virtual drives ?
    -  I noticed on Cacti graphs while  rebuilding a RAID1 array that the CPU ran hotter while the array was  being rebuilt, and cooled down once the rebuild had completed, which  indicates the rebuild was using up CPU on the  host hardware.  Should this not have been entirely transparent to the  system if the RAID activity is offloaded to this card, or is an increase  in CPU to be expected? - Creating/Deleting/Modifying a RAID volume is a CPU independent operation. 

  • Problem connecting Broadcom NetXtreme II 57711 to Cisco UCS 6120

    Hi all,
    I ordered rackmount server(C210 M1) with Broadcom NetXtreme II 57711 which I would like to connect to Cisco UCS 6120 in switching mode, but I can't make it working. Broadcom has 2 slots for SFP/SFP+ so I inserted Cisco SFP 10GBase-SR into it. I also inserted the same SFP into the Cisco 6120.
    I also tried to cross the fiber but I still got no link.
    I tried to lookup supported SFPs from Broadcom but have no luck so far. Can anybody help, please?
    The only technical specification I found is http://www.cdw.com/shop/products/default.aspx?EDC=1997284 . I don't know if it is reliable but I can't make much of it.
    Mat

    Martin,
    Both the 6100 Farbric interconnect and the Broadcom support SFP+, below I have included some supporting documentation.
    The first link shows the supported adapters for the C Series Servers (Overview of Cisco C-Series Adapters .pdf) which has a link to a datasheet for the broadcom. The second link provides a list of supported SFPs.
    http://www.cisco.com/en/US/prod/ps10265/ps10493/c-series_adapter.html
    http://www.cisco.com/en/US/partner/prod/collateral/modules/ps5455/data_sheet_c78-455693.html
    The output of show interface brief on the fabric interconnect will display which interfaces have an SFP present, you can also use the command
    show interface ethernet x/y transceiver details for more information.
    If you still have issues you can use a process of elimination, change the cable, SFPs try a different port on the fabric interconnect. Plug another
    supported device into the fabric interconnect to see if it comes up. You can use a similar process to rule in or out a problem with the Server.
    Bill

  • Ask the Expert: Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI

    Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI with Vishal Mehta and Manuel Velasco.
    The current industry trend is to use SAN (FC/FCoE/iSCSI) for booting operating systems instead of using local storage.
    Boot from SAN offers many benefits, including:
    Server without local storage can run cooler and use the extra space for other components.
    Redeployment of servers caused by hardware failures becomes easier with boot from SAN servers.
    SAN storage allows the administrator to use storage more efficiently.
    Boot from SAN offers reliability because the user can access the boot disk through multiple paths, which protects the disk from being a single point of failure.
    Cisco UCS takes away much of the complexity with its service profiles and associated boot policies to make boot from SAN deployment an easy task.
    Vishal Mehta is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco Nexus 5000, Cisco UCS, Cisco Nexus 1000v, and virtualization. He has presented at Cisco Live in Orlando 2013 and will present at Cisco Live Milan 2014 (BRKCOM-3003, BRKDCT-3444, and LABDCT-2333). He holds a master’s degree from Rutgers University in electrical and computer engineering and has CCIE certification (number 37139) in routing and switching and service provider.
    Manuel Velasco is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco UCS, Cisco Nexus 1000v, and virtualization. Manuel holds a master’s degree in electrical engineering from California Polytechnic State University (Cal Poly) and VMware VCP and CCNA certifications.
    Remember to use the rating system to let Vishal and Manuel know if you have received an adequate response. 
    Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through April 25, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hello Evan
    Thank you for asking this question. Most common TAC cases that we have seen on Boot-from-SAN failures are due to misconfiguration.
    So our methodology is to verify configuration and troubleshoot from server to storage switches to storage array.
    Before diving into troubleshooting, make sure there is clear understanding of this topology. This is very vital with any troubleshooting scenario. Know what devices you have and how they are connected, how many paths are connected, Switch/NPV mode and so on.
    Always try to troubleshoot one path at a time and verify that the setup is in complaint with the SW/HW interop matrix tested by Cisco.
    Step 1: Check at server
    a. make sure to have uniform firmware version across all components of UCS
    b. Verify if VSAN is created and FC uplinks are configured correctly. VSANs/FCoE-vlan should be unique per fabric
    c. Verify at service profile level for configuration of vHBAs - vHBA per Fabric should have unique VSAN number
    Note down the WWPN of your vhba. This will be needed in step 2 for zoning on the SAN switch and step 3 for LUN masking on the storage array.
    d. verify if Boot Policy of the service profile is configured to Boot From SAN - the Boot Order and its parameters such as Lun ID and WWN are extremely important
    e. finally at UCS CLI - verify the flogi of vHBAs (for NPV mode, command is (from nxos) – show npv flogi-table)
    Step 2: Check at Storage Switch
    a. Verify the mode (by default UCS is in FC end-host mode, so storage switch has to be in NPIV mode; unless UCS is in FC Switch mode)
    b. Verify the switch port connecting to UCS is UP as an F-Port and is configured for correct VSAN
    c. Check if both the initiator (Server) and the target (Storage) are logged into the fabric switch (command for MDS/N5k - show flogi database vsan X)
    d. Once confirmed that initiator and target devices are logged into the fabric, query the name server to see if they have registered themselves correctly. (command - show fcns database vsan X)
    e. Most important configuration to check on Storage Switch is the zoning
    Zoning is basically access control for our initiator to  targets. Most common design is to configure one zone per initiator and target.
    Zoning will require you to configure a zone, put that zone into your current zonset, then ACTIVATE it. (command - show zoneset active vsan X)
    Step 3: Check at Storage Array
    When the Storage array logs into the SAN fabric, it queries the name server to see which devices it can communicate.
    LUN masking is crucial step on Storage Array which gives particular host (server) access to specific LUN
    Assuming that both the storage and initiator have FLOGI’d into the fabric and the zoning is correct (as per Step 1 & 2)
    Following needs to be verified at Storage Array level
    a. Are the wwpn of the initiators (vhba of the hosts) visible on the storage array?
    b. If above is yes then Is LUN Masking applied?
    c. What LUN number is presented to the host - this is the number that we see in Lun ID on the 'Boot Order' of Step 1
    Below document has details and troubleshooting outputs:
    http://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-b-series-blade-servers/115764-ucs-san-tshoot-00.html
    Hope this answers your question.
    Thanks,
    Vishal 

  • Cisco UCS Director Login Problem

    Hello Community,
    I have recently installed Cisco UCS Director 5.1. According to the documentation the initial login requirements are admin for username and admin for password, see image;
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-director/vsphere-install-guide/5-1/b_Installing_UCSDirector_on_vSphere_5_1/b_Installing_UCSDirector_on_vSphere_5_1_chapter_010.html
    However, authentication keeps on failing.
    Any ideas?
    Cheers
    Carlton

    Sergey,
    If this is a real I2C issue, you may still see the same behavior on 2.0.x release if the I2C bus was not cleared before the upgrade. (in this moment I don't know if you recently performed an upgrade on the system or not)
    I2C bus tranports information about the different components of the Unified System, this, meaning Chassis, IOMs, Fans, PSU, etc...  What happens is that all those components try to send theit status update while other do the same and then the I2C bus gets overwhelmed, and then noone can really report their real status, so we usually recommend the customer ro reseat all major components, one at the time, to clear the bus and then do the upgrade, if that is not done before the upgrade, it still should be done after.
    Try reseating the Fans and PSU, one at the time, leaving a minute in between and then, IOMs one at the time, leaving three minutes in between and begining with the subordinate to cause minimun disruption.
    If this does not clear the situation, then you will need to remove one of the components already mentioned, one at the time and do a "show tech-support chassis # all brief" to see what the I2C bus reports segment by segment (chassis, Fans, PSUs...) once you remove a component and the errors on each segment stop incrementing you will have your faulty piece of hardware, and a TAC case will be needed to send a replacement.
    For further analysis or assistance, I strongly recommend a TAC case to be opened.
    -Kenny

  • Ethernet controller driver not installing after Windows Server 2008 installation on Cisco UCS blade

    I am using MDT 2010 to deploy Windows Server 2008 to a Cisco UCS B200 blade. The OS and hotfixes install with no problem. The system reboots and attempts to connect to the deployment share to continue with the task sequence and I receive an error stating
    "A connection to the deployment share could not be made. The following networking device did not have a driver installed. PCI\VEN_1137&DEV_0043&SUBSYS_00481137&REV_A2"
    The driver in question is the driver for the Ethernet controller for the UCS blade. More specifically, it is the network driver for the Palo card in the UCS Chassis. When I Ignore or Abort the install, I am able to manually install the driver and restart the
    task sequence. The build then completes successfully with no further issue. I just cannot seem to automate the driver install. Has anyone dealt with this type of issue?

    Vik and stealthfield - thank you for your responses.
    I was preparing a script to manually move the driver into the c:\windows\inf location when I had to stop to create a new task sequence for a different build. It was while building this task sequence that I found the soulution to the problem.
    In the Post Install -> Inject Drivers step of the Task Sequence, I noticed that it was executing a command of type "Inject Drivers" with a selection profile of "All Drivers" and "Install only matching drivers
    from the selection profile" selected.         
    I changed this to run a command of type "Run Command Line" and specified that it execute "%Scriptroot%\ZTIdrivers.wsf". I noticed that this was selected in one of my other builds that was working properly, so I thought I'd
    give it a try. - IT WORKED.
    So to sum up, the solution was to change the type of command being executed in the "Post Install -> Inject Drivers" step of the task sequence. After this change, the machine came up and continued the task sequence with no further issues.
    Thanks again for the responses - They were helpful and I do appreciate it.

  • Brand new 2960X and 2960XR not responding to cli commands

    I have 2 brand new 2960X switches and neither are responding to cli commands via the RJ45 to DB9 cisco cable.  Text is displayed but when I hit enter on the keyboard nothing happens and the switches just sit at whatever the last boot ouput is. 2960-XR just sits at 'vlan1, changed state to up.....' and I am never prompted for the express setup and no response to any keyboard input. 
    I know the cable/keyboard works because I can connect it to a 2911 right beside the 2960's and have no problems using the same cable. 
    Anyone seen this before?
    Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.0(2)EX1, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2013 by Cisco Systems, Inc.
    Compiled Fri 28-Jun-13 13:20 by prod_rel_team
    Nov 22 10:49:54.277: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
    Nov 22 10:49:55.602: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
    Nov 22 10:49:56.493: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/47, changed state to up
    Nov 22 10:49:56.493: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/48, changed state to up
    Nov 22 10:49:58.370: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/47, changed state to up
    Nov 22 10:49:58.412: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/48, changed state to up
    Nov 22 10:49:58.450: %PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present
    Nov 22 10:50:26.384: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up

    Hello,
    Recieved today also 2 2960-x switches.
    Had the same issue...playing arround with secureCRT settings (rts/cts, xon/xoff etc) ...no results.
    Tried Putty and it worked right away ...indeed strange have never seen this before.
    Installed latest software 150.2ex4  still the same.
    regards michel

  • Cisco UCS C220 M3S Server OS random shutdowns

    Hello good day, I am facing some issues with the Cisco UCS indicated in the subject, I have created a Raid 1 beetwen 2 HDD's of 1 TB each one, also upgraded the firmware of the UCS with the 2.0(3f) HUU tools, and upgraded everything. Then I installed Windows Server 2012 R2 Eval version (I have a proper license to install but wanted to test the OS first). Now some times the OS/Server just shutsdown, and whenever I go in to the Web GUI to check it out, it's actually powered down, I have checked the "Faults and Logs" --> System Event Logs, and I can see this happening:
    *The timestamp is from below to the top on both logs*
    MAIN_POWER_PRS: Presence sensor, Device Removed / Device Absent was asserted
    Microsoft OEM event data record, Record type: DD, Sensor Number: 0A, Event Data: 00 00 00,  Raw SEL: 37 01 00 35 0A 00 00 00 00
    (About this message with the HEX Values, it's always repeating it self with other values)
    System Software event: OS Stop sensor, OS Graceful Shutdown was asserted
    In the IMC Log this is what showed when it powered down:
     Bridge.c:1484:audit Resp:0x0
     Bridge.c:1478:audit from:kcs Fn:0x0 Cmd:0x6 Data: 0x30 0x4 
     obj/../../src/BiosSecureBootAgent.cc:101:BiosSecureBootAgent --> m_valid_state = [ 0 ] #012 m_enable_state = [ 0 ] #012 m_setupMode_state = [ 1 ] #012 m_secureBoot_state = [ 0 ] 
     obj/../../src/BiosSecureBootAgent.cc:63:get=uefiSecureBootState Received 
     bootordermgnt.cpp:2392:WriteBIOSDeviceCfg: Successfully renamed file: /mnt/jffs2/ConfigPolicy.xml.bak to /mnt/jffs2/ConfigPolicy.xml
     bootordermgnt.cpp:1310:StoreDeviceCfg: Successfully renamed file: /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT.bak to /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT
     bootordermgnt.cpp:2392:WriteBIOSDeviceCfg: Successfully renamed file: /mnt/jffs2/ConfigPolicy.xml.bak to /mnt/jffs2/ConfigPolicy.xml
     bootordermgnt.cpp:1310:StoreDeviceCfg: Successfully renamed file: /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT.bak to /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT
     bootordermgnt.cpp:2392:WriteBIOSDeviceCfg: Successfully renamed file: /mnt/jffs2/ConfigPolicy.xml.bak to /mnt/jffs2/ConfigPolicy.xml
     bootordermgnt.cpp:1310:StoreDeviceCfg: Successfully renamed file: /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT.bak to /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT
     bootordermgnt.cpp:1367:No Precision Boot DB exists..migrate old relase configuration to Precision Boot format!
     sanluis1/platform.c:116:platform_event_enable_tick_end: Configuring IR from CIMC
    (A bunch of these with other values)  common.c:945:Enabling sensor scan for sensor 0x85.
     lv_dimm.c:403:[handle_event_enable_tick]enable sensor event
     lv_dimm.c:220:[transition_function]Transition to [High Voltage Mode] Success
     lv_dimm.c:200:[transition_function]Starting Transition to [High Voltage Mode] from [Unknown Mode]
    (A lot of these with different values)  common.c:940:Disabling Sensor scan for sensor 0x89.
     lv_dimm.c:129:[lpc_reset_seen]LPC Reset Count is Different [0x15:0x16] Asserted LPC Reset Seen
     selparser.c:678: # 1D 03 00 00 01 02 00 00 DB F7 EF 54 20 00 04 25 05 00 00 00 08 00 FF FF # 31d | 02/27/2015 04:51:39 | CIMC | Entity presence MAIN_POWER_PRS #0x05 | Device Absent | Asserted
     Received event_ipmi_power_state_change Event (type=4, size=0)
     video_trigger.c:262:Sending event_ipmi_power_state_change (OFF) .
     WatchdogTimer.c:1467:Current Configuration of Watchdog timer is now stopped.
     Pilot2SrvPower.c:466:Blade Power Changed To: [ OFF ]
    <5>[se_pilot2_wakeup_interrupt]:2561:USB HS: VDD Power = OFF
    <6>drivers/bmc/usb/usb1.1/se_pilot2_udc_usb1_1.c:2540:USB 1.1 is now disconnected.
    <5>drivers/bmc/usb/usb1.1/se_pilot2_udc_usb1_1.c:2288:USB FS: VDD Power WAKEUP- Power Good = OFF
    <7>[slp_state_isr]:117:Signals SLP3n[ Asserted ] SLP5n[ Asserted ]
    <6>[platform_power_state_irq_handler]:18:VDD_PWR_GOOD: Deasserted
    In the event viewer of the Windows Server 2012
    This is the UCS specifications:
    CPU 1: Intel(R) Xeon(R) CPU E5-2609 v2 @ 2.50GHz
    CPU2: Intel(R) Xeon(R) CPU E5-2609 v2 @ 2.50GHz
    Memory: 16 GB 
    There is something really itching, is it because I have Evaluation version of the Windows Server...?
    Regards.

    Ok, I feel kind of dumb now, I have checked the tech evaluation page on Microsoft, and if it's not connected to the internet it will not inherit the three months evaluation trial, which I thought would come activated already, and only allows you up to 10 days grace period with the rearm command .... :/
    The process C:\Windows\system32\wlms\wlms.exe (WIN-UDPFG5O0K37) has initiated the shutdown of computer WIN-UDPFG5O0K37 on behalf of user NT AUTHORITY\SYSTEM for the following reason: Other (Planned)
     Reason Code: 0x80000000
     Shutdown Type: shutdown
     Comment: The license period for this installation of Windows has expired. The operating system is shutting down.
    This is what made me check it out today, I will connect it to the internet and let it activate... Meanwhile the command for the 10 days grace is:
    Slmgr /rearm
    Shutdown –r
    Like always.

  • Error: Failed to parse path in URl (Cisco UCS 6100 Series Fabric Interconnect)

    I have to shut down parts of my network due to an electrical outage this weekend. I have a Cisco UCS 6100 Server Fabric Interconnect. I am trying to backup the configuration. This is the command I am using create backup tftp://*.24.1.88 full-state enabled.  The error I receive is Error: failed to parse URI.  Which I believe URI means URL.

    Hi Parakiteiz,
    Looks like the format is incorrect and you have an extra 't' on the tftp command you provided.  Please take a look at the link below for configuration assistance.
    Creating backup operaiton.
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/1-1-1/b_CLI_Config_Guide_1_1_1/CLI_Config_Guide_1_1_1_chapter38.html#task_4704260519853629974
    Please let me know if this help

  • ISCSI- Adding iSCSI SRs to XS booting via iSCSI [Cisco UCS]

    Hello all-
    I am currently running XS 6.0.2 w/ HF XS602E001 & XS602E002 applied running on Cisco UCS B200-M3 blades. XS seems to be functioning ok, except that i cannot see the subnet assigned to my SAN, and as a result, i cannot add any SR for VM storage.
    The subnet and vNIC that i am configuring is also used for the iSCSI boot.
    The vNIC is on LAN 2 and is set to Native
    The SAN is a LeftHand P4300 connected directly to appliance ports (LAN2) on the Fabrics
    Used the following commands during installation to get the installer to see the LUN.
    echo "InitiatorName=my.lun.x.x.x" > /etc/iscsi/initiatorname.iscsi
    /opt/xensource/installer/init --use_ibft
    If i missed anything or more info is needed, please let me know.

    Thanks Padramas,
    I have 2 NICs that show up in XenCenter. Nic A is the vNIC associated with VLAN1 and provide the uplink to the rest of the network. The second NIC in XenCenter matches the MAC of the vNIC used to boot XenServer, so the NIC used for booting the OS is visible in XenCenter.
    I have tried many different thing on my own to resolve this issue. I believe i have already tried adding a 3rd vNIC to the service profile for VM iSCSI traffic, but with make another attempt.
    When configuring the vNIC for VM iSCSI traffic, do I only need to add the 3rd vNIC, or do i need to create both a vNIC and second iSCSI vNIC with Overlay vNic pointing to newly created (3rd) vNIC? My understanding is that the iSCSI vNICs are only used for booting, but I am not 100% sure.
    Thanks again for the help!

  • Windows 2008 R2 on Cisco UCS B200M networking problems

    This is driving me completely nuts.  Let me start by saying I am new to blade servers and Cisco UCS.  I did take an introduction class, and it seemed straight-forward enough.  I have a chassis with two B200M blades, on which I am trying to configure two Windows 2008 R2 servers, which I will eventually make Hyper-V servers.  This is all in a test environment, so I can do anything I want to on them.
    Right now I have installed W2008 directly on hard disks on the B200M hardware.
    The problem is this: even though I think I've configured the network hardware correctly, using the Cisco VIC driver software, I cannot get networking to work in any reliable way.  I cannot even get ping to work consistantly.  I can ping my local server address, but I cannot ping my gateway (HSRP address).  When I try, I get a "Reply from 10.100.1.x: Destination host unreachable (x being each particular server's last octet). I CAN, however, ping the individual IP addresses of the core switches.  I can also ping some, but not all, the other devices that share the servers' subnet.  There are no errors being generated, the arp tables  (for those devices I can ping) look good, netstat looks OK.  But I cannot get outside the local subnet...
    Except when I can.
    There are times when I can get all the way out to the Internet, and I can download patches from Microsoft.  When it works, it works as expected.  But if I reboot the server, oftentimes networking stops working.  Yet another reboot can get things going again.  This happens even though I've made no changes to either the UCS configs or the OS.
    I cannot figure out any reason when it works at some times and not at others.  I've made sure I have a native VLAN set, I've tried pinning to specific ports on the Fabric Interconnects.  There is just no rhyme or reason to it.
    Anyone know of where I can look?  I'm very familiar with Windows on stand-alone boxes (although it's no longer my area of expertise), and I manage a global WAN (BGP, OSPF, Nexus 7k, etc.) so I'm no dummy when it comes to networking, but I am utterly stumped on this one.        

    The problem was this: while the NICs on the blade server are called vNIC0 and vNIC1, Windows was calling vNIC1 "Local Area Connection" and vNIC0 "Local Area Connection 2".  So what I configured on UCS did not match what I was configuring in Windows.  Completely, utterly ridiculous.
    Anyway, networking is working now without any issues.  Thanks for you suggestion; it did get me looking in the right direction.

  • Problem on installing Solaris 10 on Cisco UCS-C24-M3S2 rack server.

    I've got issue on installing Solaris 10 on Cisco UCS-C24-M3S2 rack server. Solaris 10 doesn't recognize UCSC-RAID-ROM55.

    Hi dipaktimsina,
    From the documentation below it looks like Solaris doesn't have support for the embedded raid controller with the ROM55 chip. 
    http://www.cisco.com/web/techdoc/ucs/interoperability/matrix/matrix.html
    let me know if you have any questions and don't forget to rate any useful answers.

  • Monitoring Cisco UCS Manager via HP System Information Manager 7.1 (SIM)

    I am working with a customer to configure HP System Information Manager 7.1 (SIM) to monitor their Cisco UCS Manager.
    The customer is looking to monitor the following:
    - CPU Utilization on manager, blades, servers, etc...
    - Memory utilization
    - Network utilization
    - System inventory
    Alerting is needed for the following:
    - Hardware failures: memory, power supply, drive, etc...
    - Predictive failures
    - Alert messages
    I have the list of all the MIBs provided by Cisco but an having the following issues while loading them into HP SIM.
    While loading MIB "CISCO-UNIFIED-COMPUTING-TC-MIB" I get the following error message:
    Line 128: Error defining object: expected a label, found reserved symbol {
    Line in MIB: SYNTAX Gauge32 {
    Guage32 is imported from SNMPv2-SMI MIB
    To get past this error I found a version of the MIB that removes all the textual conventions that where causing errors.  I have attached the fixed MIB file to this discussion. With the fixed version of the MIB installed in SIM everything compiles and installs except the following two MIBS. CISCO-UNIFIED-COMPUTING-NOTIFS-MIBCISCO-UNIFIED-COMPUTING-CONFORM-MIB Questions:
    1. Is there any way to get the CISCO-UNIFIED-COMPUTING-TC-MIB MIB to install correctly into HP SIM?
    2. Is my MIB load order setup correctly?
    3. Has anyone had success getting HP SIM to monitor and alert for Cisco UCS manager?
    MIB Load Order:
    SNMPv2-SMI
    SNMPv2-TC
    SNMP-FRAMEWORK-MIB
    RFC1213-MIB
    IF-MIB
    CISCO-SMI
    CISCO-ST-TC
    ENTITY-MIB
    INET-ADDRESS-MIB
    CISCO-UNIFIED-COMPUTING-MIB
    CISCO-UNIFIED-COMPUTING-TC-MIB
    CISCO-UNIFIED-COMPUTING-FAULT-MIB
    CISCO-UNIFIED-COMPUTING-NOTIFS-MIB
    CISCO-UNIFIED-COMPUTING-AAA-MIB
    CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB
    CISCO-UNIFIED-COMPUTING-BIOS-MIB
    CISCO-UNIFIED-COMPUTING-BMC-MIB
    CISCO-UNIFIED-COMPUTING-CALLHOME-MIB
    CISCO-UNIFIED-COMPUTING-CAPABILITY-MIB
    CISCO-UNIFIED-COMPUTING-COMM-MIB
    CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
    CISCO-UNIFIED-COMPUTING-CONFORM-MIB
    CISCO-UNIFIED-COMPUTING-DCX-MIB
    CISCO-UNIFIED-COMPUTING-DHCP-MIB
    CISCO-UNIFIED-COMPUTING-DIAG-MIB
    CISCO-UNIFIED-COMPUTING-DPSEC-MIB
    CISCO-UNIFIED-COMPUTING-EPQOS-MIB
    CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
    CISCO-UNIFIED-COMPUTING-ETHER-MIB
    CISCO-UNIFIED-COMPUTING-EVENT-MIB
    CISCO-UNIFIED-COMPUTING-EXTMGMT-MIB
    CISCO-UNIFIED-COMPUTING-EXTVMM-MIB
    CISCO-UNIFIED-COMPUTING-FABRIC-MIB
    CISCO-UNIFIED-COMPUTING-FC-MIB
    CISCO-UNIFIED-COMPUTING-FCPOOL-MIB
    CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
    CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
    CISCO-UNIFIED-COMPUTING-HOSTIMG-MIB
    CISCO-UNIFIED-COMPUTING-IMGPROV-MIB
    CISCO-UNIFIED-COMPUTING-IMGSEC-MIB
    CISCO-UNIFIED-COMPUTING-IPPOOL-MIB
    CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB
    CISCO-UNIFIED-COMPUTING-ISCSI-MIB
    CISCO-UNIFIED-COMPUTING-LICENSE-MIB
    CISCO-UNIFIED-COMPUTING-LLDP-MIB
    CISCO-UNIFIED-COMPUTING-LSBOOT-MIB
    CISCO-UNIFIED-COMPUTING-LSMAINT-MIB
    CISCO-UNIFIED-COMPUTING-LS-MIB
    CISCO-UNIFIED-COMPUTING-MACPOOL-MIB
    CISCO-UNIFIED-COMPUTING-MAPPINGS-MIB
    CISCO-UNIFIED-COMPUTING-MEMORY-MIB
    CISCO-UNIFIED-COMPUTING-MGMT-MIB
    CISCO-UNIFIED-COMPUTING-NETWORK-MIB
    CISCO-UNIFIED-COMPUTING-NWCTRL-MIB
    CISCO-UNIFIED-COMPUTING-ORG-MIB
    CISCO-UNIFIED-COMPUTING-OS-MIB
    CISCO-UNIFIED-COMPUTING-PCI-MIB
    CISCO-UNIFIED-COMPUTING-PKI-MIB
    CISCO-UNIFIED-COMPUTING-PORT-MIB
    CISCO-UNIFIED-COMPUTING-POWER-MIB
    CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
    CISCO-UNIFIED-COMPUTING-PROC-MIB
    CISCO-UNIFIED-COMPUTING-QOSCLASS-MIB
    CISCO-UNIFIED-COMPUTING-SOL-MIB
    CISCO-UNIFIED-COMPUTING-STATS-MIB
    CISCO-UNIFIED-COMPUTING-STORAGE-MIB
    CISCO-UNIFIED-COMPUTING-SW-MIB
    CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB
    CISCO-UNIFIED-COMPUTING-SYSFILE-MIB
    CISCO-UNIFIED-COMPUTING-TOP-MIB
    CISCO-UNIFIED-COMPUTING-TRIG-MIB
    CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB
    CISCO-UNIFIED-COMPUTING-VM-MIB
    CISCO-UNIFIED-COMPUTING-VNIC-MIB
    References:
    ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-manager-supportlist.html#_Toc303691433
    http://www.hp.com/wwsolutions/misc/hpsim-helpfiles/simsnmp.pdf

    Please post "debug ccsip messages".
    Based on your debug you are getting "Cause No. 38 - network out of order."
    You may want to bind SIP to an interface that the IP address is defined which Lync points to.
    Chris

  • Oracle 11g - Solaris 10 on cisco UCS server

    I would like to know if anyone has experience with installing Oracle databases on cisco UCS servers.  I recently took over a dba shop and my client has purchased a cisco UCS server and is planning on migrating some databases currently on dedicated servers running on Solaris 10 and others running on Linux RH 5.4 platforms.  I need to find out if Oracle 11g and Solaris 10 is compatible and covered by Oracle licenses.  Does anyone have any specs and/or information on this topic?  Thanks in advance.
    Jonathan Begazo-Leon

    Jonathan,
    there's a dedicated Oracle database forum (Database) where you can post your issue. In this forum here only 3rd party to Oracle migrations using the Oracle tools migration workbench or SQL Developer will be covered. As I can't move your thread, please close this one here and post your issue again in the database forum.
    Thanks,
    Klaus

  • Cisco UCS Director Foundation (UCSDF) 5.0 Training

    Hello Community,
    Can anyone help me where i can attend the following Training for  (( Cisco UCS Director Foundation (UCSDF) 5.0 )) as i can not find a schedual in CISCO training locator .. It is highly important for me as i have an implementation soon and i need to get its knowledge .
    Thanks & Best Regards ,
    Mostafa Elgindy

    Mostafa,
    I think you'll have a little problem getting this running. There is huge interest in this topic but to be fair, Cisco has only just now (the past two weeks) released the 5.0 course materials to the instructors. So far as I know, me and two other instructors are the only instructors in Europe which are both certified to teach this class as well as actually have hands on experience with Director. In addition, we can't as instructors get our hands on the actual product outside of dCloud to actually update our knowledge for v5.0 because of the insanely stupid terms involved.
    I have been asked three times so far to deliver this course. I've said no 3 times. I wouldn't even consider it without a few weeks to prepare, so I personally won't deliver it before March. There are some guys who like reading slides that will do it sooner, but you may have issues with getting questions answered.

Maybe you are looking for

  • Memory speed problems?

    don't know if anyone else has experienced this but let me know if you have and if there is a way to fix it. So I am running XP Pro from Boot Camp 1.4. I test my Windows performance with PC Pitstop. When I was running Vista on 1.3 I tested and the mem

  • Operation could not be completed. client error not possible.

    I have a mac mini running OS10.5.8. All of a sudden I can not print with my HP1315v all in one printer. I can print a test but that is all. I get this message. "Operation could not be completed, Client error no possible". I re-installed the HP softwa

  • OO ABAP --urgent need

    hi all please send me material or pdf documents or links for learning ABAP objects starting from beginning to indeep of OO ABAP. It is very urgent.... please send me information on all types of ALVs also..

  • How to install os if cd rom is not working

    I had to install a new hard drive, but now I can't get the OS install disk to work

  • Error in source system of type BW

    I am getting the following error when I am right clicking on the BW source system and selecting 'Check' EDI: Partner Profile not available      No.332 Entry in inbound table not found       No.414 Entry in outbound table not found     No. 400