Cisco UCS with FEX system Component requirements

Hi ,
I am looking for quick suggestion for required components to have a VMware vSAN implemented using FEX system with maximum Fabric trough put. Ideally a configuration for without multipath using single Fabric switch and later on to be able to upgrade to Multipath fabric.
We are in great rush to provide POC concept and was looking if you folks can suggest me on this. If need be you want to talk to me more in detail I can available.
Appreciate your help here.
Who can I reach to able to pull up build and quote the configurations for implementing complete UCS solution.
Are these below components absolutely required ?
2 x Nexus 2232PP 10GE Fabric Extenders
The Cisco Nexus 2232PP 10GE provides 32 x 10Gb loss-less low latency Ethernet and Fiber Channel Over Ethernet (FCoE) Small Form-Factor Pluggable Plus (SFP+) server ports and eight 10 Gb Ethernet and FCoE SFP+ uplink ports in a compact 1 rack unit (1RU) form factor. They enable Seamless inclusion of UCS rack servers into UCS Manager domain with UCS blade servers when connected to the UCS 6200 Fabric Interconnects, providing converged LAN, SAN, and management connectivity.
We currently have these below servers :
2 x  UCSC-BASE-M2-C460
        524 GB RAM
        No SSDs
        No VIC Card
        4 x SAS 1 TB Drives
        1 x L1 Intel 1 Gbps Ethernet Adapter
        1 x L2 10Gbps Ethernet Adapter
        1 x LSI Mega RAID SAS 9240-8i (no RAID 5 support, Need a card that supports RAID5)
1 x  UCSC-C240-M3L
        132 GB RAM
        30 TB SAS HDD
        1 x VIC Card
        1 x Intel I350 Gigabit Ethernet Card with 4 ports
        1 x LSI Mega RAID SAS 9240-8i (no RAID 5 support, Need a card that supports RAID5)
1 x 5548UP Nexus Switch ( Will I be able to use this switch in place of Nexus 2232PP 10GE Fabric Extenders to achieve complete UCS solution)

Cisco UCS Manager 2.2 supports an option to connect the C-Series Rack-Mount Server directly to the Fabric Interconnects. You do not need the Fabric Extenders. This option enables Cisco UCS Manager to manage the C-Series Rack-Mount Servers using a single cable for both management traffic and data traffic.
If you need high performance low latency (storage, for VMware VSAN), direct connection to UCS Fabric Interconnect and/or N5k is recommended.

Similar Messages

  • Ask the Expert: Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI

    Welcome to this Cisco Support Community Ask the Expert conversation. This is an opportunity to learn and ask questions about Cisco UCS Troubleshooting Boot from SAN with FC and iSCSI with Vishal Mehta and Manuel Velasco.
    The current industry trend is to use SAN (FC/FCoE/iSCSI) for booting operating systems instead of using local storage.
    Boot from SAN offers many benefits, including:
    Server without local storage can run cooler and use the extra space for other components.
    Redeployment of servers caused by hardware failures becomes easier with boot from SAN servers.
    SAN storage allows the administrator to use storage more efficiently.
    Boot from SAN offers reliability because the user can access the boot disk through multiple paths, which protects the disk from being a single point of failure.
    Cisco UCS takes away much of the complexity with its service profiles and associated boot policies to make boot from SAN deployment an easy task.
    Vishal Mehta is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco Nexus 5000, Cisco UCS, Cisco Nexus 1000v, and virtualization. He has presented at Cisco Live in Orlando 2013 and will present at Cisco Live Milan 2014 (BRKCOM-3003, BRKDCT-3444, and LABDCT-2333). He holds a master’s degree from Rutgers University in electrical and computer engineering and has CCIE certification (number 37139) in routing and switching and service provider.
    Manuel Velasco is a customer support engineer for Cisco’s Data Center Server Virtualization TAC team based in San Jose, California. He has been working in the TAC for the past three years with a primary focus on data center technologies such as Cisco UCS, Cisco Nexus 1000v, and virtualization. Manuel holds a master’s degree in electrical engineering from California Polytechnic State University (Cal Poly) and VMware VCP and CCNA certifications.
    Remember to use the rating system to let Vishal and Manuel know if you have received an adequate response. 
    Because of the volume expected during this event, our experts might not be able to answer every question. Remember that you can continue the conversation in the Data Center community, under subcommunity Unified Computing, shortly after the event. This event lasts through April 25, 2014. Visit this forum often to view responses to your questions and the questions of other Cisco Support Community members.

    Hello Evan
    Thank you for asking this question. Most common TAC cases that we have seen on Boot-from-SAN failures are due to misconfiguration.
    So our methodology is to verify configuration and troubleshoot from server to storage switches to storage array.
    Before diving into troubleshooting, make sure there is clear understanding of this topology. This is very vital with any troubleshooting scenario. Know what devices you have and how they are connected, how many paths are connected, Switch/NPV mode and so on.
    Always try to troubleshoot one path at a time and verify that the setup is in complaint with the SW/HW interop matrix tested by Cisco.
    Step 1: Check at server
    a. make sure to have uniform firmware version across all components of UCS
    b. Verify if VSAN is created and FC uplinks are configured correctly. VSANs/FCoE-vlan should be unique per fabric
    c. Verify at service profile level for configuration of vHBAs - vHBA per Fabric should have unique VSAN number
    Note down the WWPN of your vhba. This will be needed in step 2 for zoning on the SAN switch and step 3 for LUN masking on the storage array.
    d. verify if Boot Policy of the service profile is configured to Boot From SAN - the Boot Order and its parameters such as Lun ID and WWN are extremely important
    e. finally at UCS CLI - verify the flogi of vHBAs (for NPV mode, command is (from nxos) – show npv flogi-table)
    Step 2: Check at Storage Switch
    a. Verify the mode (by default UCS is in FC end-host mode, so storage switch has to be in NPIV mode; unless UCS is in FC Switch mode)
    b. Verify the switch port connecting to UCS is UP as an F-Port and is configured for correct VSAN
    c. Check if both the initiator (Server) and the target (Storage) are logged into the fabric switch (command for MDS/N5k - show flogi database vsan X)
    d. Once confirmed that initiator and target devices are logged into the fabric, query the name server to see if they have registered themselves correctly. (command - show fcns database vsan X)
    e. Most important configuration to check on Storage Switch is the zoning
    Zoning is basically access control for our initiator to  targets. Most common design is to configure one zone per initiator and target.
    Zoning will require you to configure a zone, put that zone into your current zonset, then ACTIVATE it. (command - show zoneset active vsan X)
    Step 3: Check at Storage Array
    When the Storage array logs into the SAN fabric, it queries the name server to see which devices it can communicate.
    LUN masking is crucial step on Storage Array which gives particular host (server) access to specific LUN
    Assuming that both the storage and initiator have FLOGI’d into the fabric and the zoning is correct (as per Step 1 & 2)
    Following needs to be verified at Storage Array level
    a. Are the wwpn of the initiators (vhba of the hosts) visible on the storage array?
    b. If above is yes then Is LUN Masking applied?
    c. What LUN number is presented to the host - this is the number that we see in Lun ID on the 'Boot Order' of Step 1
    Below document has details and troubleshooting outputs:
    http://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-b-series-blade-servers/115764-ucs-san-tshoot-00.html
    Hope this answers your question.
    Thanks,
    Vishal 

  • CIsco UCS-C200M2 with Unified Communication Products

    Hi,
    If anybody knows what are the Unified Communication products we can install on Cisco UCS solution with EXS VMware ESXi 4.0 Standard Edition.
    If any other products pls let me know that alo.
    Thanks in Advance.
    Regards,
    Sunish

    Yes, the DocWiki covers this on the Supported Applications page. It is worth mentioning that only there are specific hardware component requirements of the C200M2 for VTG support.
    Please rate useful responses.

  • Monitoring Cisco UCS Manager via HP System Information Manager 7.1 (SIM)

    I am working with a customer to configure HP System Information Manager 7.1 (SIM) to monitor their Cisco UCS Manager.
    The customer is looking to monitor the following:
    - CPU Utilization on manager, blades, servers, etc...
    - Memory utilization
    - Network utilization
    - System inventory
    Alerting is needed for the following:
    - Hardware failures: memory, power supply, drive, etc...
    - Predictive failures
    - Alert messages
    I have the list of all the MIBs provided by Cisco but an having the following issues while loading them into HP SIM.
    While loading MIB "CISCO-UNIFIED-COMPUTING-TC-MIB" I get the following error message:
    Line 128: Error defining object: expected a label, found reserved symbol {
    Line in MIB: SYNTAX Gauge32 {
    Guage32 is imported from SNMPv2-SMI MIB
    To get past this error I found a version of the MIB that removes all the textual conventions that where causing errors.  I have attached the fixed MIB file to this discussion. With the fixed version of the MIB installed in SIM everything compiles and installs except the following two MIBS. CISCO-UNIFIED-COMPUTING-NOTIFS-MIBCISCO-UNIFIED-COMPUTING-CONFORM-MIB Questions:
    1. Is there any way to get the CISCO-UNIFIED-COMPUTING-TC-MIB MIB to install correctly into HP SIM?
    2. Is my MIB load order setup correctly?
    3. Has anyone had success getting HP SIM to monitor and alert for Cisco UCS manager?
    MIB Load Order:
    SNMPv2-SMI
    SNMPv2-TC
    SNMP-FRAMEWORK-MIB
    RFC1213-MIB
    IF-MIB
    CISCO-SMI
    CISCO-ST-TC
    ENTITY-MIB
    INET-ADDRESS-MIB
    CISCO-UNIFIED-COMPUTING-MIB
    CISCO-UNIFIED-COMPUTING-TC-MIB
    CISCO-UNIFIED-COMPUTING-FAULT-MIB
    CISCO-UNIFIED-COMPUTING-NOTIFS-MIB
    CISCO-UNIFIED-COMPUTING-AAA-MIB
    CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB
    CISCO-UNIFIED-COMPUTING-BIOS-MIB
    CISCO-UNIFIED-COMPUTING-BMC-MIB
    CISCO-UNIFIED-COMPUTING-CALLHOME-MIB
    CISCO-UNIFIED-COMPUTING-CAPABILITY-MIB
    CISCO-UNIFIED-COMPUTING-COMM-MIB
    CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
    CISCO-UNIFIED-COMPUTING-CONFORM-MIB
    CISCO-UNIFIED-COMPUTING-DCX-MIB
    CISCO-UNIFIED-COMPUTING-DHCP-MIB
    CISCO-UNIFIED-COMPUTING-DIAG-MIB
    CISCO-UNIFIED-COMPUTING-DPSEC-MIB
    CISCO-UNIFIED-COMPUTING-EPQOS-MIB
    CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
    CISCO-UNIFIED-COMPUTING-ETHER-MIB
    CISCO-UNIFIED-COMPUTING-EVENT-MIB
    CISCO-UNIFIED-COMPUTING-EXTMGMT-MIB
    CISCO-UNIFIED-COMPUTING-EXTVMM-MIB
    CISCO-UNIFIED-COMPUTING-FABRIC-MIB
    CISCO-UNIFIED-COMPUTING-FC-MIB
    CISCO-UNIFIED-COMPUTING-FCPOOL-MIB
    CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
    CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
    CISCO-UNIFIED-COMPUTING-HOSTIMG-MIB
    CISCO-UNIFIED-COMPUTING-IMGPROV-MIB
    CISCO-UNIFIED-COMPUTING-IMGSEC-MIB
    CISCO-UNIFIED-COMPUTING-IPPOOL-MIB
    CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB
    CISCO-UNIFIED-COMPUTING-ISCSI-MIB
    CISCO-UNIFIED-COMPUTING-LICENSE-MIB
    CISCO-UNIFIED-COMPUTING-LLDP-MIB
    CISCO-UNIFIED-COMPUTING-LSBOOT-MIB
    CISCO-UNIFIED-COMPUTING-LSMAINT-MIB
    CISCO-UNIFIED-COMPUTING-LS-MIB
    CISCO-UNIFIED-COMPUTING-MACPOOL-MIB
    CISCO-UNIFIED-COMPUTING-MAPPINGS-MIB
    CISCO-UNIFIED-COMPUTING-MEMORY-MIB
    CISCO-UNIFIED-COMPUTING-MGMT-MIB
    CISCO-UNIFIED-COMPUTING-NETWORK-MIB
    CISCO-UNIFIED-COMPUTING-NWCTRL-MIB
    CISCO-UNIFIED-COMPUTING-ORG-MIB
    CISCO-UNIFIED-COMPUTING-OS-MIB
    CISCO-UNIFIED-COMPUTING-PCI-MIB
    CISCO-UNIFIED-COMPUTING-PKI-MIB
    CISCO-UNIFIED-COMPUTING-PORT-MIB
    CISCO-UNIFIED-COMPUTING-POWER-MIB
    CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
    CISCO-UNIFIED-COMPUTING-PROC-MIB
    CISCO-UNIFIED-COMPUTING-QOSCLASS-MIB
    CISCO-UNIFIED-COMPUTING-SOL-MIB
    CISCO-UNIFIED-COMPUTING-STATS-MIB
    CISCO-UNIFIED-COMPUTING-STORAGE-MIB
    CISCO-UNIFIED-COMPUTING-SW-MIB
    CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB
    CISCO-UNIFIED-COMPUTING-SYSFILE-MIB
    CISCO-UNIFIED-COMPUTING-TOP-MIB
    CISCO-UNIFIED-COMPUTING-TRIG-MIB
    CISCO-UNIFIED-COMPUTING-UUIDPOOL-MIB
    CISCO-UNIFIED-COMPUTING-VM-MIB
    CISCO-UNIFIED-COMPUTING-VNIC-MIB
    References:
    ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-manager-supportlist.html#_Toc303691433
    http://www.hp.com/wwsolutions/misc/hpsim-helpfiles/simsnmp.pdf

    Please post "debug ccsip messages".
    Based on your debug you are getting "Cause No. 38 - network out of order."
    You may want to bind SIP to an interface that the IP address is defined which Lync points to.
    Chris

  • This component requires that the embedded font be declared with embedAsCFF=false.

    I'm getting the following warning for my project.
    "warning: incompatible embedded font 'MyFont' specified for views::MyViewInnerClass0 (MyViewInnerClass0_61) . This component requires that the embedded font be declared with embedAsCFF=false."
    Here's what I have in my style.css file.
    /* CSS file */
    @namespace s "library://ns.adobe.com/flex/spark";
    @namespace supportClasses "spark.globalization.supportClasses.*";
    @namespace views "views.*";
    @font-face {
              src: url("assets/MyFont.ttf");
      fontFamily: "MyFont";
      advancedAntiAliasing: true;
      embedAsCFF: true;
    @font-face {
              src: url("assets/MyFont.ttf");
      fontFamily: "MyFont";
      advancedAntiAliasing: false;
      embedAsCFF: false;
    The 2nd font section I have is what is suggested as the fix in most places but that isn't working out for me. I wonder if I'm missing something else.

    I tried changing the name and it didn't work. Tried all sort of combinations too and none worked. Tried a different font and that didn't work too.
    Turns out the problem wasn't in the declaration of the fonts but where I was using it.
    I initially had the font declared globally
    global
       fontFamily: DroidSansMono;
    I saw that, in your comment you had mentioned "..then apply it to the component" so I applied the font to the label component
    s|Label
      fontFamily: DroidSansMono;
    and boom.. no warning. Problem solved.
    Thanks so much.

  • This component requires that the embedded font be declared with embedAsCFF=true.

    Hey all,
    I fall into a small problem with fonts embedding. In my application I have embedded over 50 fonts and all expect one works as expected.
    That one shows an error "warning: incompatible embedded font 'Algerian-CFF' specified for spark.components::RichEditableText (RichEditableText310) . This component requires that the embedded font be declared with embedAsCFF=true."
    I have been looking all over the internet for similar problem, without success. Why this font is not working while all the rest does? Any clues?
    /* CSS file */
    @namespace s "library://ns.adobe.com/flex/spark";
    /* embedded font */
    @font-face {
    src: url("ttf/ALGER.ttf");
    fontFamily: Algerian-CFF;
    Thanks.

    Thanks,
    My issue is not to embed a font twice. Let me describe the issue so this will helpful.
    I have embed a fonts like below code.And apply LucidaBlackletterSpark font for spark component but it gives me error like
    "warning: incompatible embedded font 'LucidaBlackletterSpark' specified for spark.components::RichEditableText (RichEditableText2301) . This component requires that the embedded font be declared with embedAsCFF=true".
    But Font have already embedAsCFF property true. I am not able to find the solution why it is give me this warning.Due to that i am not able to embed a font.
    @font-face {
              src: url("assets/fonts/LucidaBlackletter.ttf");
              fontFamily: LucidaBlackletterSpark;
              embedAsCFF: true;
    @font-face {
              src: url("assets/fonts/LucidaBlackletter.ttf");
              fontFamily: LucidaBlackletterMX;
              embedAsCFF: false;

  • Cisco UCS Management Pack for System Center Operations Manager 2007 R2 Login Error

    I have Cisco UCS 1.4 (3q) and just installed the MP v2.1 for Cisco UCS, however when I click on the "Management Pack Events" alert view in the SCOM console, there are error for event number 19900.  The description of the error is as follows:
    Description:
    CISCO UCS R2 MP (https://10.x.x.x/nuova) [CISCO.UCS.R2.Proxy.LoadCache.ProbeAction.vbs] : CISCO UCS Login Error: Authentication failed (Code: 551)
    I noticed that it's looking for the /nuova directory, but in order to login to our UCS environment, we usually just go to the IP address - so I'm wondering if that has something to do with it?  I've verified that when going directly to the IP from Internet Explorer I can login using the opsmgr credentials we specifically created for this account.  I've also gone through the process of creating a run-as account on the SCOM side and associated it with the correct profiles.
    Any help is greatly appreciated.

    Troubleshooting has found out its user error, wrong password configured.

  • Cisco Prime Infrastructure 1.2 with Cisco Prime Network Control System Hardware Appliance

    Hi Team,
    I have  following BOM
    Cisco Prime Infrastructure
    R-PI-1.2-K9
    Cisco Prime Infrastructure 1.2
    1
    R-PI-1.1-500-K9
    Prime Infrastructure 1.2 Software - 500 Device Base Lic
    1
    L-PILMS42-500
    Prime Infrastructure LMS 4.2 - 500 Device Base Lic
    1
    L-PINCS12-500
    Prime Infrastructure NCS 1.2 - 500 Device Base Lic
    1
    PRIME-NCS-APL-K9
    Cisco Prime Network Control System Hardware Appliance
    1
    PI-APL-IMAGE-1.2
    Cisco Prime Infrastructure 1.2 Appliance Software
    1
    Pls let me know if we have both NCS and LMS preinstalled with Cisco Prime Infrastructure 1.2 Appliance Software orwe need seperate appliance or server for LMS 4.2. 
    Regards

    Hi Scott,
    Thanks for the response but I got to know that LMS and NCS are combined in single ISO image from PI 1.2 and can be installed on the same physical NCS appliance.
    Can you pls check this.
    Regards

  • Want to hear about vCAC when used with Cisco UCS Director... How are you seeing this done?

    I have a client that has both VMware vCloud Automation Center, and Cisco UCS Director.
    They wish to constuct a net-new (Greenfield) data center and are hearing from both VMware and Cisco.
    I have researched, and found little regarding the merger of the two.
    I realize that very likely vCAC is teh "main" management platform, while Cisco UCSD will handle the more "physical hardware" tasks.
    REST API's will be leveraged as well.
    What have you seen written and done in this space when using BOTH?
    Please send me any thoughts or links to relevant data.
    I am having a hard time locating good data so that I an advise the client in a good way.

    Bahi,
    just to illustrate what mess this is, I tested for you on Leopard (10.5) and Snow Leopard (10.6) using the same wide gamut monitor. Here are two screenshots from that experiment. I converted the screenshots from my display profile to sRGB to show you what I see and scaled down 50% (this is a 30" behemoth). First Leopard.
    You see they are all the same, but different from the sRGB export you provided. The GB sticker is too blue and the tint on the car is wrong. I doubt anybody but a photographer would notice though.
    Next is Snow Leopard:
    Here the 320 pixel, the 480 pixel and the 960 pixel image are different from the 720 pixel, the 720p and the 1080p ones. Neither is strictly correct as they are all different from the sRGB display. This is consistent with their being no real color management, just gamma corrections and color space transforms (video is usually not stored as RGB but as YUV, necessitating a transform for display). Annoying, but not much you can do about it.
    Just doing some quick googling I came across many mentions of issues such as this. It clearly is just a big mess.

  • My mac is running 10.7.2 and wondering why the "find my mac" feature is not working. Instead, it says I need to system upgrade requires.. I believe it's already upgraded together with the 10.7.2

    My mac is running 10.7.2 and wondering why the "find my mac" feature is not working. Instead, it says I need to system upgrade requires.. I believe it's already upgraded together with the 10.7.2

    i get the spinning beach ball in all of my applications
    have a look at this article: Troubleshoot the spinning beach ball

  • UCS C240 M4 with Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+

    Hi All,
    Have a few UCS C-series questions:
    If I have a UCS C240 M4 rack server with Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+, but do not have fabric interconnect(s), I cannot use the UCS VIC1227 for anything, can I? The VIC ports HAVE to be connected to the FI(s) in order to be integrated with the UCS Manager. There is no local UCS manager software running on the server itself, is there?
    It is useless to have this card in the server without the FI(s), isn’t it?
    The OS that is going to be installed on the server is not going to see those 10GB ports on the VIC, isn’t it?
    And if there are no additional PCIe NICs installed in the server, I am stuck with the two 1GB onboard NICs, is that correct?
    Any input is appreciated.

    do not have fabric interconnect(s), I cannot use the UCS VIC1227 for anything, can I?
    The VIC 1227 can be used to integrate the server with UCSM, but that does NOT mean that is its unique function... the VIC 1227 is a CNA card that can be used whether your server is in standalone mode (no Fabric Interconnects) or integrated with UCSM.
    If the server is not connected to a Fabric Interconnect (FI), it still has CIMC (Cisco Integrated Management  Controller) which can be configured by attaching a monitor to the server and a keyboard, press F8 when you see the Cisco logo and then you can configure the IP, subnet, gateway, NIC mode and others... this may help: https://www.youtube.com/watch?v=KHQBvwO7pUU
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/e/1-0/gs/guide/b_Getting_Started_Guide/b_Getting_Started_Guide_chapter_0101.html#task_3F8535D6A9574BCD806B25FEBF44615D
    http://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-c200-m1-high-density-rack-mount-server/111455-setup-cimc-c-series.html  <<< Little old but still helps.
    It is useless to have this card in the server without the FI(s), isn’t it?
    It is NOT useless to have the card in the server without the FIs, having the servers integrated only allows you to take advantage of the flexibility of Service Profiles but the VIC card still has the same capabilities whether you have an FI or not.
    The OS that is going to be installed on the server is not going to see those 10GB ports on the VIC, isn’t it?
    See above
    And if there are no additional PCIe NICs installed in the server, I am stuck with the two 1GB onboard NICs, is that correct?
    Same answer as above
    Let me know if you have further questions. IF I covered everything, please mark the question as "answered" for future users with the same doubts.
    -Kenny

  • Registering with the WebEx Data Center and the Cisco WebEx Node Management System

    Dear guys, ...
    Please help,
    i want to implement to webex node ASR1000, i have read in "Configuring the Cisco Webex Node for ASR 100.pdf", there is prerequisites to implement it, that is "Registering with the WebEx Data Center and the Cisco WebEx Node Management System"
    Can someone tell how to "Registering with the WebEx Data Center and the Cisco WebEx Node Management System"
    Are there any step by step documentation to "Registering with the WebEx Data Center and the Cisco WebEx Node Management System"?
    Thank you
    BR

    You should have received a PAK Key with your order.  Go to Cisco licensing and enter the PAK Key as this will start the process.  Once the PAK Key is validated a screen will be displayed to enter your request for ASR 100 integration.  It normally takes a few days to a couple of weeks to get the information back from WebEx needed to configure your ASR.
    If you did not get a PAK Key contact your WebEx rep to get the process started to integrate your ASR to your WebEx site.
    Hope this helps
    John

  • Cisco UCS C220 with VIC 1225

    Hello,
    We have Cisco UCS C220 M3 with VIC 1225 card installed. We connected only one 10G port of VIC 1225 to Nexus 5548UP switch. But I do not see this port on switch and in CIMI the status for this port shows Link Down. I wanted to to iSCSI boot from storage NetApp FAS2240 but since I don't see this port on my Nexus switch I am unable to do boot from NetApp. I tried both ports on VIC 1225 with same result. Please I need help in this matter. I know I am missing something very simple but can't figure this out.
    Thanks,
    Salman

    Hi Kenny,
    Here is the answers:
    -What slot is this card installed in?
    Mezzenine
    -How many CPUs does the server have installed? (1 OR 2 CPUs can make the difference)
    2x 2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz
    -Is the PCIe slot enabled in BIOS? << Let us know if you don't know how to check it from CIMC
    I believe I did. Server>BIOS>BIOS advanced> PCIe (Let me know if this correct)
    -Have you confirmed that the cable is good?
    I have changed four cables. I am using SFP-H10GB-CU2M= Twinax cable.
    -If the switch does not even see the port and CIMC says it is down, have you confirmed the switch port is properly configured?
    CIMI says “Link Down” in VIC adapter General area. The switch interface config has only “switchport mode access” in default vlan 1.
    -What is the firmware running on the server and the OS?
    We upgraded the firmware with latest ucs-c220-huu-1.5.4-3.iso.
    Let me share with you the complete BoM of the server:
    UCSC-C220-M3S              1x  UCS C220 M3 SFF w/o CPU  mem  HDD  PCIe  PSU  w/ rail kit
    UCS-CPU-E5-2690              2x  2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz
    UCS-MR-1X082RY-A    16x 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v
    CAB-9K10A-UK              2x  Power Cord 250VAC 10A BS1363 Plug (13 A fuse) UK
    UCSC-PCIE-CSC-02    1x           Cisco VIC 1225 Dual Port 10Gb SFP+ CNA
    UCSC-PCIE-QSFP              1x  Qlogic QLE8242-CU Dual Port 10 GbE FCoE CNA
    UCSC-HS-C220M3              2x  Heat Sink for UCS C220 M3 Rack Server
    UCSC-RAIL1              1x  Rail Kit for C220 C22 C24 rack servers

  • Cisco UCS 6324 Fabric Interconnect Used as a FEX?

    Hi,
    Is it possible to use the Cisco UCS 6324 Fabric Interconnect as a FEX to uplink UCS 5108 Blade Chassis to Cisco UCS 6200 Series Fabric Interconnects? Thank you.

    How does it work if I want to add a second 5108 to a pair of 6324's? Having the 6324's replace the IOM (FEX) modules is cool but would you need to buy IOM's for the second chassis and then use up either 4 x 10GB ports or the 1 x 40GB or would I need to purchase 2 more 6324's?
    Thanks in advance.

  • Is Live Cache System refresh required with APO refresh

    Hi APO Experts:
       I have a question concerning the refresh of an APO QAS system. \
       If I have an APO system refreshed from a production APO system, is it required that I refresh the Live Cache as well?
       We have just refreshed our APO QAS system from production and I was thinking it could be easier to just reinstall a new database for Live cache in QAS then refreshing it from production Live Cache......
    Please share your words of wisdom. Thanks! - Will S.

    Hi Will,
    I think LiveCach refresh with production is not required. But you need to down the LC and then start it.
    LiveCach is a temporary storage area and it will refresh with database.
    I suggest please post this in BASIS forum.
    Regards,
    Kishore Reddy.

Maybe you are looking for

  • Hi,Firefox Team!You can add games in this browser?

    With games,Firefox costumers will be very happy!Games like Minecraft,Angry Birds series,Neighbours from Hell series,Ricochet series etc. and... with achievments.This browser is incredible,you can do more...

  • T61 will not boot with nvidia quadro 140m driver

    Hi all, A couple of weeks ago, after allowing MS update to install some FTDI driver updates, my system will not boot up and hangs shortly after the initial vista loading screen. The screen goes black with some HD activity and eventually reboots. Afte

  • How do I replace a photo in Illustrator CS6?

    I am trying to replace a photo in an existing layout and I am having difficulties. I have done it before and I remember I would right click and replace the photo. But now, every time I right click on the image, it doesn't give me the option. What am

  • HP 8 G2 GPS Doesn't Work

    Yet another problem with this tablet: The GPS does not work. Nokia HERE maps: Perpetually "Waiting for GPS".Google Maps can't show location in GPS only mode.GPS Status & Toolbox app never gets past "Looking for GPS location..." Anything to try before

  • Asynchronous function module - why RFC ?

    Hi, I am using CALL FUNCTION ... STARTING NEW TASK ... DESTINATION 'NONE' to start an asynchronous process. For this to work, the called function module must be unfortunately RFC enabled. Actually I do not want that anybody external can call this. Ca