Cisco7600 SIP-400 MIB Required

Hello :
   I have Cisco 7609 router and we have observed that router is rebooted due to the following error ;
SLOT 3: Apr 13 16:06:26.621: %CARDMGR-2-ESF_DEV_ERROR: An error has occurred on Egress ESF Engine: Control Store Parity Error SLOT 3: Apr 13
Slot -3 we have SIP-400 card. We would like to know if there is any MIB which can monitir such reboots.
Thanks in advance.
Regards
Arjun

I am having the same issue, but haven't replace the card yet. I have reset and re-seat it though.

Similar Messages

  • Difference between OSM-2+4GE-WAN+ and 7600-SIP-400

    hy guys,
    If I want to use one of them as uplink, which are better ?

    Depending on your current and future requirements the decision for SIP-400 or OSM-GEWAN needs to be taken.
    As they both are different product sets meant to cater to different set of business requirements.
    SIP-400
    a) Provides you with capability to aggregate different flavours of
    OC12,OC48 and other WAN and GE Interfaces as well as use them for uplink,
    b) Supports VPLS
    c) Supports MQC with conventional QOS.
    d) Supports ATM Cell Relay.
    e) Occupies 1 slot space
    OSM-GEWAN.
    a) Provides only Gigabit aggregation and uplink.
    b) Supports VPLS.
    c) Doesnt support ATM Cell Relay.
    d) Supports MQC and conventional QOS.
    e) Occupies 1 slot space,
    Above are some difference in summary.
    But if you requirement is to have only Gig aggregation and Gig uplinks then OSM
    by far is a good choice. But if you have your aggregation done, and are looking for WAN aggregation with Enchanced features like conventional QOS and VPLS, Cell Relay etc, with the option if choosing the media types for your aggregation, then SIP-400 is vis-a-vis a good choice.
    This comparision doesnt take into consideration the throughput performance of both categories vis-a-vis.
    HTH-Cheers,
    Swaroop

  • Can we use SPA-4XOC3-POS-V2 on 7600-SIP-400

    Hi,
    We have ordered 2 x SPA-4XOC3-POS to use on 7604, we have received SPA-4XOC3-POS-V2 from our supplier.
    I know that the SPA-4XOC3-POS-V2 are for the 12000, is there a way to use them on a 7600-SIP-400??
    Any help is appreciated.
    Thank you.
    Hitch

    This SPA is not supported on SIP-400 on 7600s. You need to get a NON V2 SPA.
    Atif

  • Cannot configure service-policy on SIP-400

    I have cisco 7606 with SIP-400 on slot1 , and I try to apply service-policy output on the interface pos1/1/0, after enter the command, the system
    generate the error "queue-limit is invalid command w/o other queueing feature".
    Why I cannot apply the service-policy?

    Thanks Marcio.
    I have added failover details to the client's tnsnames file (see below), but still i get the '500 - The Network Adapter could not establish the connection' error:
    TESTDB =
    (DESCRIPTION =
    (ADDRESS = (PROTOCOL = TCP)(HOST = lontestdb01-vip)(PORT = 1526))
    (ADDRESS = (PROTOCOL = TCP)(HOST = lontestdb02-vip)(PORT = 1526))
    (LOAD_BALANCE = TRUE)
    (FAILOVER = TRUE)
    (CONNECT_DATA =
    (SERVER = DEDICATED)
    (SERVICE_NAME = ESTDB)
    (FAILOVER_MODE =
    (BACKUP=lontestdb02-vip)
    (TYPE=select)
    (METHOD=preconnect)
    (RETRIES=180)
    (DELAY=5)
    Bal - the output of crs_stat -t is as follows (please note the listener on node 1 is intentionally down)
    -bash-3.00$ crs_stat -t
    Name Type Target State Host
    ora....B1.inst application ONLINE ONLINE lonestdb01
    ora....B2.inst application ONLINE ONLINE lonestdb02
    ora....DB1.srv application ONLINE ONLINE lonestdb01
    ora....DB2.srv application ONLINE ONLINE lonestdb02
    ora....BOTH.cs application ONLINE ONLINE lonestdb01
    ora....DB1.srv application ONLINE ONLINE lonestdb02
    ora....LIVE.cs application ONLINE ONLINE lonestdb01
    ora....DB2.srv application ONLINE ONLINE lonestdb02
    ora....NDBY.cs application ONLINE ONLINE lonestdb02
    ora.ESTDB.db application ONLINE ONLINE lonestdb02
    ora....01.lsnr application OFFLINE OFFLINE
    ora....b01.gsd application ONLINE ONLINE lonestdb01
    ora....b01.ons application ONLINE ONLINE lonestdb01
    ora....b01.vip application ONLINE ONLINE lonestdb01
    ora....02.lsnr application ONLINE ONLINE lonestdb02
    ora....b02.gsd application ONLINE ONLINE lonestdb02
    ora....b02.ons application ONLINE ONLINE lonestdb02
    ora....b02.vip application ONLINE ONLINE lonestdb02
    Many thanks to everyone that's helped so far
    Rup

  • 7600 SIP-400 looped to same 7600

    Hi,
    We are proposing to install SIP-400's into our PE's 7600 (sup32) in order to provide egress traffic shaping and qos for our customers.
    We are proposing to connect the SIP gig interfaces back to another line card on the same device, instead of putting another switch in front of our existing PE. This saves us a switch and lets us take advantage of the port density in our current 7600 PE's (which is why we purchased them in the first place).
    We also plan to utilise the same approach to implement pwe xconnects on the SIP-400 subinterfaces. VLAN uniqueness per port is the key feature of the SIP-400 that facilitates this.
    Has anyone run a similar setup? Any experiences to share?
    I have tested in the lab and can't see any issues so far.
    Does anyone know of a more cost effective qos / shaping solution for Ethernet tails? The SIP or ES20 based solutions seem overpriced for the pretty basic functionality we are after here. Doesn't have to be a Cisco box.
    Kent.

    "Doesn't have to be a Cisco box. "
    If you're still interested in solving this (or haven't already), you can mail me at [email protected]
    Cheers,
    Anton

  • SPA scale options on SIP-400

    Hi All,
    Are there any scalability limitations on 7600 with a SIP-400 module?
    Specifically looking for pointers in identifying the maximum number of 1xGig ports supported per SIP-400 on a 7600 router.
    Thanks
    ~sultan

    Hi Jerry,
    Thanks for your response.
    I am looking for a 'matrix' that gives me various combinations I can stick in, though you mention that each bay can support upto 2x1G or 5x1G, that is not the case.
    When I try to stick in 3 nos. of 2x1G V2 SPA I get a message something like capacity exhausted/expended etc... and the SPA goes 'down'. In addition there are loads of other SIP/SPA incompatibilities... I wonder how difficult it would have been to make a single SIP capable of having ALL the available SPAs in any combination... but then this is Cisco :-)
    I have also spoken to TAC, but the response was limited to 'Please check the product specifications'.
    Thanks
    ~sultan

  • (Linecard image not present) at WS-SSC-600 and 7600-SIP-400

    i install two modules WS-SSC-600 and 7600-SIP-400 in slot 5 and 6 in 13-slot chassis and give this output from show power (Linecard image not present)
      for both cards.
    supervisor engine is : VS-S720-10G with sub-module VS-F6K-PFC3CXL and VS-F6K-MSFC3
    IOS : s72033-advipservicesk9-mz.122-33.SXI9
    what that mean and how to fix it ?

    Ok problem solved by upgrade ios to another version but the new image must contains (_wan) in image name for example (
    s72033-advipservicesk9_wan-mz.122-33.SXJ6 ) otherwise the two modules will not powered up.

  • PPPoE Cisco 6500 + 7600-SIP-400

    Hello,
    we use a lot of Cisco 6500 switches across our network. I bought one 7600-SIP-400 with one SPA-5X1GE-V2 module.
    Unfortunatelly I have found that there is no command support for PPPoE in my IOS version 12.2 SXI13. 
    Can somebody tell me which IOS version do I have to use to get command support for PPPoE Server?
    Thank you.
    Milan

    "Doesn't have to be a Cisco box. "
    If you're still interested in solving this (or haven't already), you can mail me at [email protected]
    Cheers,
    Anton

  • Port Analizer Port gigabit cisco 7600 SIP-400 SPA-5X1GE-V2

    Hi,
    I have a Wan LINK  (Layer 3), so I want to check if there are retransmissions in this link.
    Do you know if there is a way that a can do SPAN on a GigabitEthernet Port on SPA-5X1GE-V2 (Cisco 7600 Platform)
    I tried but i got this error:
    R(config)#monitor session 10 source int GigabitEthernet 4/0/0
    % Interface(s) Gi4/0/0 not supported as monitor source(s) on this platform
    Cisco IOS Software, c7600rsp72043_rp Software (c7600rsp72043_rp-ADVIPSERVICESK9-M), Version 15.1(2)S, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2011 by Cisco Systems, Inc.
      4    0  4-subslot SPA Interface Processor-400  7600-SIP-400      
      5    2  Route Switch Processor 720 (Active)    RSP720-3CXL-GE
     4/0 5xGE SPA                    SPA-5X1GE-V2     
    thanks for the Help.

    Hi,
    Does anyone have any suggestions?

  • SIP-400 SPA-2X1GE

    Does SPA interface (SPA-2X1GE) support DWDM SFP? What is maximum number of SPA-2x1GE in one SIP-400 module? Does OSM-4G and 7600-ES20 module support DWDM SFP. What is difference between those cards if we talk about this card as core-facing card, and which card is best solution for core-facing.

    Cisco XR 12000 Series SPA Interface Processor 10G 12000-SIP-600 support DWDM.
    SPA-2X1GE
    SPA-1XOC12-ATM
    SPA-8XCHT1/E1

  • SIP 400 Bad Request

    I'm getting a bad request error when attempting to an outbound SIP call on a IP2IP gateway (H323 -> SIP).
    It's a slightly odd configuration as we will only be using this route for outgoing calls only. The only error message I get is:
    //-1/xxxxxxxxxxxx/SIP/Error/sipsdp_add_standard_lines: media_src_address is NULL; c-line is not added
    SIP Invite message:
    Sent:
    INVITE sip:[email protected]:5060 SIP/2.0
    Via: SIP/2.0/UDP 192.168.1.1:5060;branch=z9hG4bK11222C
    From: "anonymous" <sip:[email protected]>;tag=404CF30-282
    To: <sip:[email protected]>
    Date: Wed, 16 May 2007 13:09:44 GMT
    Call-ID: [email protected]
    Supported: 100rel,timer
    Min-SE: 1800
    Cisco-Guid: 15103203-2971783453-520093696-2887190163
    User-Agent: Cisco-SIPGateway/IOS-12.x
    Allow: INVITE, OPTIONS, BYE, CANCEL, ACK, PRACK, COMET, REFER, SUBSCRIBE, NOTIFY, INFO, UPDATE, REGISTER
    CSeq: 101 INVITE
    Max-Forwards: 70
    Remote-Party-ID: <sip:[email protected]>;party=calling;screen=yes;privacy=full
    Timestamp: 1179320984
    Contact: <sip:[email protected]:5060>
    Call-Info: <sip:192.168.1.1:5060>;method="NOTIFY;Event=telephone-event;Duration=2000"
    Expires: 180
    Allow-Events: telephone-event
    May 16 13:09:44.608 UTC: //-1/xxxxxxxxxxxx/SIP/Info/HandleUdpSocketReads: Msg enqueued for SPI with IP addr: 192.168.1.2:5060
    May 16 13:09:44.608 UTC: //-1/xxxxxxxxxxxx/SIP/Transport/sipTransportProcessNWNewConnMsg: context=0x00000000
    May 16 13:09:44.608 UTC: //-1/xxxxxxxxxxxx/SIP/Msg/ccsipDisplayMsg:
    Received:SIP/2.0 400 Bad Request
    Via: SIP/2.0/UDP 192.168.1.1:5060;branch=z9hG4bK11222C
    From: "anonymous" <sip:[email protected]>;tag=404CF30-282
    To: <sip:[email protected]>
    Call-ID: [email protected]
    CSeq: 101 INVITE
    User-Agent: 2N StarGate V-02.20.47
    Allow: INVITE, BYE, ACK, CANCEL, OPTIONS
    Content-Length: 0
    Any ideas?

    For what its worth, I had the same problem from Callmanager to an IOS IPIPGW. I was getting the SIP/2.0 400 Bad Request - 'Malformed/Missing Contact field' error message. Turns out I had mistyped my caller id mask and was sending characters in place of numbers. By correcting it, my problem went away.
    Todd

  • MIBs required for "HP Smart Array P420/1GB FBWC"

    Hi,
    One of our customer purchaged "HP Smart Array P420/1GB FBWC
    " to integrate that we required the following details.
    -          MIB
    -          Alarm Documentation
    -          Alarm List
    -          Features like AlarmUpload
                     Is it supported?
                     If yes how to perform(eg., set based/get based etc.,)
    Could you please help in getting the above details for "HP Smart Array P420/1GB FBWC"
    Thanks in advance.
    Ezhil

    Hi:
    You may also want to post your question on the HP Business Support Forum -- ProLiant Storage Systems section:
    http://h30499.www3.hp.com/t5/ProLiant-Storage-Systems/bd-p/itrc-265#.VG4Bo3ktC9I

  • MIB Required for Bandwidth Monitoring on Cisco 3800 and 3900 series Routers

    Hi Team,
    Need your help here.
    I am planning to do Bandwidth Monitoring on Cisco 3800 and 3900 series Routers. I want to know the exact MIB which I need to use for getting this done.
    Thanks,
    Karthik Anbumani

    Matt, based on feature navigator GLBP is supportted on 3800 series.
    Go to this link and search by feature (GLBP)
    http://tools.cisco.com/ITDIT/CFN/jsp/index.jsp
    HTH
    Jorge

  • M-CMTS with SIP-600 SPA

    Dear all,
    I have a few question regarding M-CMTS with SIP-600 SPA.
    - Scenario 1: I have a uBR10012 with linecard MG20X20V(0 DS, 20 US lic) + SIP 600 and i want to use M-CMTS with  SIP-600 connect to RFGW1/RFGW10. Is that possible to do like this?
    -Scenario 2: I have a uBR10012 with line card MG3GX60V (72DS, 60 US) + SIP 600, also have a RFGW1 with 98 DS, so I still have 16 DS available, can i use SIP-600 connect to that RFGW1 do use those available DS?
    I need some help/advice about those situations, please help me.

    Hello,
    Yes, it should.
    You could check Table 4-9 VPLS Feature Compatibility by SIP and SPA Combination:
    http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_adapters/configuration/7600series/76cfgsip.html#wp1270728
    There are some restricition about H-VPLS on c7600/SIP, like it could be seen at the "VPLS Configuration Guidelines"
    section of above link. But they are generic for SIP-600 itself:
    – H-VPLS with Q-in-Q edge—Requires a Cisco 7600 SIP-600 in the uplink, and any LAN port or Cisco 7600 SIP-600 on the downlink.
    - H-VPLS with MPLS edge requires either an OSM module, Cisco 7600 SIP-600, or Cisco 7600 SIP-400 in both the downlink (facing UPE) and uplink (MPLS core).
    As for SPAs - restriction is about H-VPLS and FastEthernet one:
    "Note: H-VPLS is not available on Fast Ethernet SPAs"
    http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_adapters/configuration/7600series/76cfgeth.html#wp1196808
    Thanks,
    Sergey

  • VPLS support for SIP-600 and 10GE-SPA

    Hello all,
    is SIP-600 (7600-SIP-600) with Cisco 1-port 10GE SPA V2 (SPA-1X10GE-L-V2) support VPLS ?
    i see in datasheet SIP-600 support for VPLS but in 10GESPA datasheet there is no VPLS features support
    Thanks
    Regards,

    Hello,
    Yes, it should.
    You could check Table 4-9 VPLS Feature Compatibility by SIP and SPA Combination:
    http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_adapters/configuration/7600series/76cfgsip.html#wp1270728
    There are some restricition about H-VPLS on c7600/SIP, like it could be seen at the "VPLS Configuration Guidelines"
    section of above link. But they are generic for SIP-600 itself:
    – H-VPLS with Q-in-Q edge—Requires a Cisco 7600 SIP-600 in the uplink, and any LAN port or Cisco 7600 SIP-600 on the downlink.
    - H-VPLS with MPLS edge requires either an OSM module, Cisco 7600 SIP-600, or Cisco 7600 SIP-400 in both the downlink (facing UPE) and uplink (MPLS core).
    As for SPAs - restriction is about H-VPLS and FastEthernet one:
    "Note: H-VPLS is not available on Fast Ethernet SPAs"
    http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_adapters/configuration/7600series/76cfgeth.html#wp1196808
    Thanks,
    Sergey

Maybe you are looking for

  • Copy File from One Location to Another Location through xcopy or any

    Hi, I Need to copy one file from one location to another location. That file need to save in C:\Windows\System32 folder I need to create one .bat file and i want apply that bat as a startup script through GPO. I tried through XCopy if i test in machi

  • PL-SQL-ORA-01704 - String literal too long

    Hello guyz; I am trying to store a value of over 4000 character long in a CLOB column and I got the error message that says "PL-SQL-ORA-01704 - String literal too long". What can I do to overcome this challenge? Thanking you for your usual support.

  • How to get the callback from an asynchronous BPEL?

    Hi, I have deployed an asynchronous BPEL on Oracle Application Server as a Web Service. The BPEL is named CreditRatingBPEL. The input is a social security number (Ssn) and the output is a credit rating. Now I have some troubles in consuming BPEL with

  • Why is the webpage jumping all over the place with parallax scrolling?

    Hi all, I'm getting a little frustrated here... I've built a looooong (10,200 pixel) parallax scrolling site, when I click 'Preview' it plays like a dream, but when I render the HTML, view in browser or publish to business catalyst to view, it just j

  • User access to VIEW in oracle database

    Hi, We have an issue with the user gpdashboard. I have explicitly given the select on view gpcomp1.OPENDISPUTES. It can query the table but returns 0 rows (no error). Whereas gpcomp1, when queries this view, returns 8000+ rows. Do you know what could