Client GWI version10: setup.msi issue after implementing note 1562571

Hi,
I have installed version 10 of the client based groupware integration on a CRM 6.0 system. Up till now, we were not able to let synchronization work (screen with the options was greyed out).
I had created a message for SAP and after some exchange they advised me to implement note 1562571:Solution for ISScript.msi error. We were not having this error but as SAP had a look into our system, I followed the advise.
After implementing this note via SNOTE, I got an error (which I didn't had before!) when I tried to install the synchronization software saying that the setup.msi was not correct (taking a look into SE80 bsp appl: CRMCMP_GW_WC, the file attached is setup.exe).
Did someone had the same issue? Any help is very appreciated!
Thanks in advance,
Yasmine Marchal

Hi ,
I think there is a note which can solve the msi issue , I havent implemented it .. please check Master Note - 1563898 ( this is for 7.0 EHP1 i think )  . You can look for the right note for CRM 6.0 at the service marketplace.
I have configured Groupware Int for Outlook 10 and CRM 7.0 EHP1 . Initially we were facing this error where the SAP DEFAULT profile was getting downloaded when we clicked on the Edit Sync settings. Is this what was happening with you ??
We created a new profile in GWIPROFILE and maintained the crm_ui_profile parameter with the correct business role in SU3 and now we can synchronize.
Let me know if you were able to resolve the issue with a note .
Edited by: Neha M on Sep 29, 2011 1:24 PM

Similar Messages

  • MATP- error after implementing note

    Dear All,
    We are working on MATP scenario. After configuring all the necessary settings we run availability check in simulation.
    Initially when we ran availability check for small quantity, it was confirming in APO ( In ATP simulation). But while providing larger quantity, it was showing an ABAP error.
    At the same time in R3, system gave an error saying u201Cerror in calling up function u201CBAPI_APOATP_CHECKu201D in APO server XYZ a calculation field is defined too smallu201D while checking availability for larger quantity.
    To overcome this situation, we had implemented a note u201C1005131u201D. Now the dump in APO and error message in R3 is not coming, but it not confirming orders.
    (When we check materials availability in R3, missing part button does not appear but at the same time system does not confirm any quantity)
    Have anyone of you have faced similar situation? Please reply if anyone has any clue regarding this issue.
    We are using SCM 7.0
    Regards,
    Nitesh

    Hi Nitesh,
    Are you using phantom assemblies ?
    There can be a  error during PDS  explosion that causes the error. We faced the same error and implemented note 1147324.
    Please implement note 1147324
    Thanks,
    Pavan Verma
    Edited by: Pavan Verma on Jan 21, 2010 11:38 PM

  • After implementing Note 992032 getting errors in Bex workbook

    Hi All,
    After Implementing the note 992032 (You must first implement Notes 932065, 935140, 948389, 964580 and 969846, which provide information about using transaction SNOTE. Otherwise, problems and syntax errors may occur when you deimplement some notes) getting error messages in BEx workbook when try to filter on any InfoObject but when I run query I'm getting data but not able to filter, we are using BI 7 on patch 11. When implementing the note number 964580 it's giving error and this particular note number is not yet implemented.
    Getting error messages like:
    1. Error reading the data of InfoProvider 0FIAR_O03
    2. An error occurred in the program:
    3. ORA-20000: Insufficient privileges ORA-06512: at "SYS.DBMS_STATS", line 2150 ORA-06512: at "SYS.DBMS_STATS", line 14112 ORA-06512: at line 1
    4. System error in program CL_RSR_WWW_RENDERER and form GET_FILTER_VALUES_CHA:03 (see long text)
    Before implementing 992032 everything worked well.
    Could anyone please help!
    King Regards
    Suman

    We are getting similar errors after applying BW SP11 yesterday on our dev BW system.  I've opened a message with SAP support .  If anyone gets a solution for this please post it.
    Regards,
    Ron.

  • Error in Executing Stock Reports in Prod after implementing notes

    HI All,
    We are getting below errors when we execute Stock Reports in production
    EError in BW: VALID_RETIME_ISECT-4-
    EError reading the data of InfoProvider ZIM_C113
    EError while reading data; navigation is possible
    I>> Row: 1785 Inc: RSDRC_NCUM_ROUTINES Prog: RSDRC_NCUM_ROUTINES
    We had started implementing below Notes which could have caused the issue. By mistake we had not taken in to consideration the pre and post implementaion of the Notes. Hence we cancelled the transport of the Note in to Production. Post this activity we are getting these errors.
    Note 1505587
    Notes 1524269 Subsequent correction for Note 1505587and
    1564948 Non-cumulatives: Subsequent corrections
    to Note 1505587.
    Now we have completed implementation of the Notes in Quality Env.
    Please can someoone adivce it there could be another other impact of transport this notes to Production. Scenario is that we have done a limited testing of few reports in Quality Env and foresee a risk in transporting to Prod.
    Please share if there is any experience on this scenario.
    Regards,
    Nitin

    Thanks Rishi..Whether I need to check in ST02,program buffer for that??How to resolve this issue??
    Program buffer                 PXA
    abap/buffersize               300000     kB    Size of program buffer
    abap/pxa                      shared           Program buffer mode.
    This is the current size of our program buffer..

  • Extraction issue after sap note

    Hi Experts.
    After applying sap note 1331090 to fix a program error while running extractoru2019s, one issue was solved but another one came up.
    Now when a datasource is executed it appears to run without problems, but no data is extracted, it finishes successfully with 0 records, even when there´s data to extract. This happens for all datasources generated for our planning area.
    Someone ever saw this issue?
    Thanks in advance,
    TP

    Hi,
    You could have missed some other Sub notes of this main note which you have mentioned. Kindly go through the note carefully and reapply the same.Still if you face the problem then I suggest you raise the issue with SAP.
    Thanks,
    Harsh

  • Download Fireftp issues after restarting not downloaded

    Something is wrong. I downloaded FireFTP and even donated $10. It says to restart and I did but FireFTP doesn't download and add to firefox. Please HELP. Need to get my website up and running.

    FireFTP is a Firefox add-on. You will not find it in Finder. You will find it on the Firefox menus I mentioned in my earlier post.

  • MSI-issue 1603 after packing Master Collection CS6 with AAME 3.1

    Hello,
    i can't install the costum Setup msi file, that i ceatad with the Adobe Application Manager Enterprise Edition 3.1  if I start the Setup, the MSI close after a few seconds.
    The target System is a Windows 7 64bit with SP1.
    In the Logs i've created there are following issues:
    === Logging stopped: 20.03.2015  15:43:03 ===
    MSI (c) (04:B8) [15:43:03:622]: Product: Adobe_MasterCollection_CS6 -- Installation operation failed.
    MSI (c) (04:B8) [15:43:03:622]: Das Produkt wurde durch Windows Installer installiert. Produktname: Adobe_MasterCollection_CS6. Produktversion: 1.2.0000. Produktsprache: 1033. Hersteller: Adobe Systems Incorporated. Erfolg- bzw. Fehlerstatus der Installation: 1603.
    The only thread i've found was here, but there is no solution for my Issue.
    Adobe Acrobat update error: 1603 | 11.0.07/11.0.08/11.0.09
    Does anybody  have an idea ? Thanks for help

    Hi Ned.
    thank you for your answer.
    I've done all the steps in the knowlegdebase, that you send. But the issue is not solved by these steps. The expected solution with the Adobe Creative Cleaner Tool has no effect.

  • Dll issues after deploying application Equitrac Express Client 4.2.1

    We have deployed .msi application using command following
    cmd /c xcopy "Equitrac Express Client.msi" "c:\" /E /C /R /H /K /Y&msiexec.exe /i "c:\Equitrac Express Client.msi" EQCASNAME="EQUITRAC-CAS" EQLANGUAGE="en" ADDLOCAL="Common,DRC,DesktopPrinting,WindowsPrinting"
    /q
    application deployed fine but missing dll's  which breaks some of application functions
    Eqdtpsp.dll,
    EQPortMonitorHook.dll,
    EQPortMonitorSpy.dll
    couldn't find any errors in - AppDiscovery.Log, AppIntenteval.Log,AppEnforce.Log 
    Need help...

    Why on earth do you copy the .msi file to the root of C: -drive?!
    You can simply use the application model and when creating the deployment type by just inserting the correct installation command which appears in this case to be
    msiexec /i "Equitrac Express Client.msi" EQCASNAME="EQUITRAC-CAS" EQLANGUAGE="en" ADDLOCAL="Common,DRC,DesktopPrinting,WindowsPrinting" /qn
    As long as the "Equitrac Express Client.msi" is copied to your content source and that source is accessible by the ConfigMgr through unc path (like \\server\source\Equitrac Express) you should be just fine. ConfigMgr client will copy the .msi package
    to %windir%\ccmcache\xx\ and it will be run from there (with the command you provided in the deployment type). There's absolutely no need to do any copying to anywhere.
    What goes for the missing .dlls, have you tried running the installation command (what I described above) with system account (using psexec -s cmd) before implementing it to ConfigMgr and checked that everything works fine?

  • VPN Client Issue after Vista Upgrade

    Not sure if this should be posted here, if not please let me know.
    My organization has recently implemented Vista via an Upgrade-in-Place Process that takes an imaged system (Windows XP Pro - 32bit) and upgrades the system with a network image of Windows Vista Enterprise. Applications are left installed and herein lies my problem.
    I'm using Cisco VPN Client 5.0.04, the client worked fine before the upgrade, after the upgrade, not so well.
    While troubleshooting I noted the Cisco Systems VPN Adapter was no longer listed as being installed under Network Adapters in the Windows Device Manager, there was however an adapter, labled 6to4 adapter with an exclamation point. I went through the uninstall process for the Cisco VPN Client, rebooted and reinstalled. When trying to connect, I can use one of two pcf files (both are a back up of one another), the first connection profile goes through the motion of connection, tries to contact the security gateway, and states "Not Connected"
    I enabled logging on the connection and tried again. Here's an excerpt from that log:
    09:37:18.278 04/21/09 Sev=Warning/2 CERT/0xA3600038
    Successfully added Key Usage fields to be matched.
    7 09:37:19.792 04/21/09 Sev=Warning/2 CERT/0xA3600038
    Successfully added Key Usage fields to be matched.
    8 09:37:20.338 04/21/09 Sev=Warning/2 CERT/0xE3600001
    Failed to launch application using cert pipe due to error: 0x800b010a.
    9 09:37:20.338 04/21/09 Sev=Warning/2 IKE/0xE300009B
    Failed to generate signature: Signature generation failed (SigUtil:97)
    10 09:37:20.338 04/21/09 Sev=Warning/2 IKE/0xE300009B
    Failed to build Signature payload (MsgHandlerMM:489)
    11 09:37:20.338 04/21/09 Sev=Warning/2 IKE/0xE300009B
    Failed to build MM msg5 (NavigatorMM:312)
    12 09:37:20.338 04/21/09 Sev=Warning/2 IKE/0xE30000A7
    Unexpected SW error occurred while processing Identity Protection (Main Mode) negotiator:(Navigator:2263)
    Has anyone seen this behavior after an upgrade from XP to Vista? I'm I going to have to start with a fresh install? I appreciate any suggestions or advice.
    Thanks,
    Jimi

    I finally figured out this problem and I feel it should at least be shared for another person who runs into this problem.
    The problem was resolved by loading my personal certificates (the one that is read by the smart card reader and used to authenticate me on VPN) needed to be added to the personal certificates folder in the Local Machine layer.
    I did this by opening up an MMC window --> Adding the certificates snap-in (in windows 7 it distinguishes 3 different layers, so choose the local user and the computer layer) --> and then copying the certificates in the personal folder located under Certificates - Current User into the personal folder located in Local Machine.
    The most likely reason this happened to me is that the image I was working with had security settings blocking the certificates to be read at the current user level and not at the local machine level. Therefore, it's a problem with out image and the security policies put in place at the registry level and/or group policies placed in Active Directory. This is more of a workaround than an actual fix to the problem, but at least it pinpoints where the break is happening.
    Now I can push the image back to the developers to review the security policies placed in the image.

  • Issues AFTER installing owb patchset 10.1.0.3

    Hello,
    I'm running into issues after upgrading OWB92 to 10G. Current setup: Server: OS - AIX 64-bit, OWB 10.1.0.1
    Clients: XP(SP2) - OWB 10.1.0.3.
    Problem: can not connect to repository (10.1.0.1) - using Client (10.1.0.3). This started to happen after I upgraded the client to 10.1.0.3, before that, everything looked good. "Readme" notes for 10.1.0.3 patch for Win32 lead you to believe that the same patch could be applied to the server, but that does not work.
    Questions: Is there a 10.1.0.3 patch for AIX - I can not find one. Do I have to rollback client patch to resolve this?
    Thanks in advance,
    Alex.

    Hello,
    thank you for your response. The patch number you provided is the one for DB; I was looking for a 10.1.0.3 patch for OWB binaries. There is a patch set like that, out there on OTN for Windows (as of DEC. 17) - I could not find the same one for AIX.
    Thanks,
    Alex.

  • Issues after installing apps r12.1.1 on IBM AIX server 6.x

    hi ,
    I have done the single node Apps r12.1.1 installation on IBM AIX 6.x server. I am requesting someone to please help me with the following issues.
    1. The installation has happened on a single node..single dir structure /U02/….. At present, I am able to open all HTML pages, but not any form. While opening forms, its giving following error.
    FRM 92101: There was a failure in the forms server during startup. This could happen due to invalid configuration.
    Please look into the web server log files for details.
    2. At present commands and TOPs don’t work (e.g. sqlplus, or $APPL_TOP etc). How they can be setup so that the commands can be run anywhere and cd $XXX_TOP commands can be issued to move to respective TOPs.
    3. I ran the adautocfg.sh after implementation. While running, I saw that it configured the XXX_TOPs. But, unable to use them. What else is required to be run? Did I miss out on any other files?
    Thanks in advance.
    Regards,
    Vamshi

    Hi,
    1. The installation has happened on a single node..single dir structure /U02/….. At present, I am able to open all HTML pages, but not any form. While opening forms, its giving following error.
    FRM 92101: There was a failure in the forms server during startup. This could happen due to invalid configuration.
    Please look into the web server log files for details.This is a generic error, so please check the application.log file for details about the error.
    2. At present commands and TOPs don’t work (e.g. sqlplus, or $APPL_TOP etc). How they can be setup so that the commands can be run anywhere and cd $XXX_TOP commands can be issued to move to respective TOPs.You need to source the application/database env file, $APPL_TOP/APPS<CONTEXT_NAME>.env and $ORACLE_HOME/<CONTEXT_NAME>.env
    Please see "Oracle Applications Maintenance Utilities" for details -- Page 1-11/1-12
    Oracle Applications Maintenance Utilities
    http://download.oracle.com/docs/cd/B53825_03/current/acrobat/121admu.pdf
    3. I ran the adautocfg.sh after implementation. While running, I saw that it configured the XXX_TOPs. But, unable to use them. What else is required to be run? Did I miss out on any other files?You need to source the application env file again to set this custom top.
    Please see old threads which discuss the same topic.
    How to create a custom top in R12
    How to create a custom top in R12
    CUSTOM_TOP
    http://forums.oracle.com/forums/search.jspa?threadID=&q=CUSTOM_TOP&objID=c3&dateRange=all&userID=&numResults=15&rankBy=10001
    Thanks,
    Hussein

  • Date format Issue after HRSP Update

    Hi,
    We are faced with a strange issue after HRSP update was applied on our client system (upgraded from SAP-KE-30 to SAP-KE-36).
    There is an outgoing interface which picks up all the the starters into the local government pension scheme and updates a B2A document. This is implemented via a z-program.
    When we look at the out put after the interface has run for the  vast majority of employees it shows their date of birth as 21.05.1968 when it should show it as 21051968. This only appears to have happen after the HRSP's have been applied.
    No modifications have been made to the z-program. What could be the reason for this issue. has anyone faced such an issue post HRSP update?
    Any pointers on how to further investigate and resolve the issue will be most helpful.
    Regards

    Hello Iside,
    In this case we can try to reload the software on the BlackBerry Smartphone to make sure it is running the latest version and there are no issues with the OS on the device.
    To do this we would need to back up the BlackBerry Smartphone. Please open the BlackBerry Desktop Manager and connect your device. Click on the Backup and Restore options and select Back Up. Please note the location where the backup is being saved as we will need to access it later to restore the BlackBerry Smartphone.
    Once you have backed up your BlackBerry Smartphone please follow the link below to complete a clean reload of the BlackBerry Smartphone software.
    Link: http://www.blackberry.com/btsc/KB11320
    Please test the date once the software is reloaded prior to restoring the backup.
    Thank you
    -DrP
    Come follow your BlackBerry Technical Team on Twitter! @BlackBerryHelp
    Be sure to click Kudos! for those who have helped you.
    Click Solution? for posts that have solved your issue(s)!

  • Performance issue after Upgrade from 4.7 to ECC 6.0 with a select query

    Hi All,
    There is a Performance issue after Upgrade from 4.7 to ECC 6.0 with a select query in a report painter.
    This query is working fine when executed in 4.7 system where as it is running for more time in ECC6.0.
    Select query is on the table COSP.
    SELECT (FIELD_LIST)
            INTO CORRESPONDING FIELDS OF TABLE I_COSP PACKAGE SIZE 1000
            FROM  COSP CLIENT SPECIFIED
            WHERE GJAHR IN SELR_GJAHR
              AND KSTAR IN SELR_KSTAR
              AND LEDNR EQ '00'
              AND OBJNR IN SELR_OBJNR
              AND PERBL IN SELR_PERBL
              AND VERSN IN SELR_VERSN
              AND WRTTP IN SELR_WRTTP
              AND MANDT IN MANDTTAB
            GROUP BY (GROUP_LIST).
       LOOP AT I_COSP      .
         COSP                           = I_COSP      .
         PERFORM PCOSP       USING I_COSP-_COUNTER.
         CLEAR: $RWTAB, COSP                          .
         CLEAR CCR1S                         .
       ENDLOOP.
    ENDSELECT.
    I have checked with the table indexes, they were same as in 4.7 system.
    What can be the reson for the difference in execution time. How can this be reduced without adjusting the select query.
    Thanks in advance for the responses.
    Regards,
    Dedeepya.

    Hi,
    ohhhhh....... lots of problems in select query......this is not the way you should write it.
    Some generic comments:
    1. never use SELECT
                       endselect.
       SELECT
      into table
       for all entries in table
      where.
       use perform statment after this selection.
    2. Do not use into corresponding fields. use exact structure type.
    3. use proper sequence of fields in the where condition so that it helps table go according to indexes.
        e.g in your case
              sequence should be
    LEDNR
    OBJNR
    GJAHR
    WRTTP
    VERSN
    KSTAR
    HRKFT
    VRGNG
    VBUND
    PARGB
    BEKNZ
    TWAER
    PERBL
    sequence should be same as defined in table.
    Always keep select query as simple as possible and perform all other calculations etc. afterwords.
    I hope it helps.
    Regards,
    Pranaya

  • What are the major issues in implementation SAP CRM sales and CIC.

    Hi
    We are newly implanting the project to the mobile Manfaturing Company. Our Clint is going for are looking to implement the CIC interaction center win Clint and the Sales modules of CRM .
    We have some 3rd parry raw data with us with that raw data we are calling to the customers and we want create the opportunity in the CIC after that we will convert the opportunity as a sales with our other sales people. After  that  they will sale that product to that customers.
    We have the back end of the R/3 SD, MM modules implemented for Clint.
    Now 1) I want to know after implementation what are the major issues will come in the project normally for the conman  Sales and CIC Win Clint projects kindly give the some  issues normally come  and solutions  for the problems also.
    My motto is that if I know the issues I can make preparation  for that conman issues and I will make my project with good effective and smooth running ..
    with Regards,
    prakesh
    Edited by: prakesh on Dec 9, 2009 6:04 AM

    hi prakesh,
    firstly, cic winclient is an older version and obsolete so its better to implement the new crm version.
    secondly, in any case if you want to implement, then your 3rd party raw data has to be mapped with the SAP system which could be a problem. Middleware could be a lot of effort. Rest all depends on how much customization you need for your business requirement in cic and sales. In case you are implementing standard functionality mostly then no major complications are expected otherwise lot of development effort may be required.
    regards
    shikha

  • Application publishing issues after temp profile usage

    We haven't figured out the solusion to this issue but we do know the cause and a workaround for it that works, kind of...
    A brief description would be that after permission issues for some users roaming profile storage on the fileserver application publishing and several applications fail in a different way for different users. This is due to the creation of C:\Users\TEMP,
    TEMP.DOMAIN etc folders rather than using C:\Users\Username folders. The issue seems to be that App-V 5 client remembers this temporary folder in a way that we havent figured out yet, all references to the temp folders for each users account UID in the
    registry has been removed and the roaming profie was deleted locally and on the fileserver YET app-v remembers the path C:\Users\TEMP and tried to create shortcuts etc there without success --> the packag then failes completely and dissapears from the client/powershell
    Get-AppvClientPackage view as if its not even published to the user.
    The BIG question is how the "#¤/&¤ can you get the App-V client to forget about the C:\Users\TEMP foders and retun to the users correct folder? We have tried to remove all user accounts UID from HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\AppV\MAV\Configuration\Packages
    etc and also the users profiles so this data must be stored somewhere else. The issue is local to specific XenApp servers, if the temporary profile wasnt created on a server the issue will never appear there.
    The workaround is that all users with the issue have full access to the paths C:\Users\TEMP and C:\Users\TEMP.DOMAIN folders, however when app-v generates shortcuts in that folders we'll need to manually move them to the correct path so that they are
    available to the users, smooth!
    The environment is based on 4x Windows 2008 R2 server with citrix XenApp 6.5. App-V 5 SP1 RDS client is installed and configured to use a single publishing server "Add-AppvPublishingServer -Name SERVERNAME -URL
    http://FQDN:8080"
    The details:
    (we think) Some users had the follow error since they couldn't access the faulty profile path TEMP or TEMP.DOMAIN:
    Failed to create file by callback data: \Device\HarddiskVolume2\Users\USERNAME\AppData\Roaming\Microsoft\AppV\Client\VFS\FE7FE758-FDD8-4208-AF3D-E2505AEF6791\AppData\Adobe\Acrobat\
    Another user got only one package (the only package without a shortcut):
    This user receives 1 out of 8 packages.
    We have tried removing the local and centrally stored roaming profile without any change.
    The following is recorded in the event viewer (Microsoft\AppV\Client\Admin):
    Log Name:      Microsoft-AppV-Client/Admin
    Source:        Microsoft-AppV-Client
    Date:          2014-02-04 09:30:04
    Event ID:      19104
    Task Category: Publishing Refresh
    Level:         Error
    Keywords:      Publishing Refresh
    User:          DOMAIN\username
    Computer:      XENAPPSERVER1.domain.com
    Description:
    Part or all packages publish failed.
     published: 1
     failed: 8
    Please check the error events of 'Configure/Publish Package' before this message for the details of the failure.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-AppV-Client" Guid="{E4F68870-5AE8-4E5B-9CE7-CA9ED75B0245}" />
        <EventID>19104</EventID>
        <Version>1</Version>
        <Level>2</Level>
        <Task>36</Task>
        <Opcode>0</Opcode>
        <Keywords>0x8000000000800000</Keywords>
        <TimeCreated SystemTime="2014-02-04T08:30:04.164025400Z" />
        <EventRecordID>661</EventRecordID>
        <Correlation />
        <Execution ProcessID="3376" ThreadID="34620" />
        <Channel>Microsoft-AppV-Client/Admin</Channel>
        <Computer>XENAPPSERVER1.domain.com</Computer>
        <Security UserID="S-1-5-21-XXXXXXXX" />
      </System>
      <EventData>
        <Data Name="Value1">1</Data>
        <Data Name="Value2">8</Data>
      </EventData>
    </Event>
    In addition to the above the following is recorded for every failed package (Microsoft\AppV\Subsystems-RegistryStaging), however the package that works arent displayed in the log.
    Log Name:      Microsoft-AppV-Subsystems-RegistryStaging/Debug
    Source:        Microsoft-AppV-Subsystems-RegistryStaging
    Date:          2014-02-04 09:30:02
    Event ID:      2002
    Task Category: None
    Level:         Information
    Keywords:     
    User:          DOMAIN\username
    Computer:      XENAPPSERVER1.domain.com
    Description:
    Configure package called on already configured package '{a849ce4c-2b7b-46a9-b54e-c72e61858de1}' version '{e780bf5c-effa-4419-bd4a-03bcc394baf4}'.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-AppV-Subsystems-RegistryStaging" Guid="{1f4a896a-fea6-4862-bbeb-aaa190ae31c0}" />
        <EventID>2002</EventID>
        <Version>0</Version>
        <Level>4</Level>
        <Task>0</Task>
        <Opcode>0</Opcode>
        <Keywords>0x8000000000000000</Keywords>
        <TimeCreated SystemTime="2014-02-04T08:30:02.853894400Z" />
        <EventRecordID>89</EventRecordID>
        <Correlation ActivityID="{01AFCC48-F800-0001-4FF3-2C81241CCF01}" />
        <Execution ProcessID="3376" ThreadID="34620" ProcessorID="3" KernelTime="544" UserTime="3885" />
        <Channel>Microsoft-AppV-Subsystems-RegistryStaging/Debug</Channel>
        <Computer>XENAPPSERVER1.domain.com</Computer>
        <Security UserID="S-1-5-21-XXXXXXXX" />
      </System>
      <EventData>
        <Data Name="package">{A849CE4C-2B7B-46A9-B54E-C72E61858DE1}</Data>
        <Data Name="version">{E780BF5C-EFFA-4419-BD4A-03BCC394BAF4}</Data>
      </EventData>
    </Event>
    We also notice the following errors in Microsoft\AppV\Subsystems-shortcuts when AppV tries to generate icons in the wrong/old profile path (cmd.exe "set" displayes the correct path but why cant appv get this info?):
    Log Name:      Dbg
    Source:        Microsoft-AppV-Subsystems-shortcuts
    Date:          2014-01-28 13:55:47
    Event ID:      130
    Task Category: None
    Level:         Error
    Keywords:     
    User:          DOMAIN\username
    Computer:      XENAPPSERVER1.domain.com
    Description:
    Failed to write shortcut file 'C:\Users\TEMP.DOMAIN\AppData\Roaming\Microsoft\Windows\Start Menu\Programs\' with error '6629316385409335299'.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-AppV-Subsystems-shortcuts" Guid="{a7782ffe-c5f5-4554-ab1c-acb874c1ccf9}" />
        <EventID>130</EventID>
        <Version>1</Version>
        <Level>2</Level>
        <Task>0</Task>
        <Opcode>0</Opcode>
        <Keywords>0x8000000000000000</Keywords>
        <TimeCreated SystemTime="2014-01-28T12:55:47.925264700Z" />
        <EventRecordID>251</EventRecordID>
        <Correlation />
        <Execution ProcessID="3376" ThreadID="3628" ProcessorID="0" KernelTime="378" UserTime="136" />
        <Channel>Dbg</Channel>
        <Computer>XENAPPSERVER1.domain.com</Computer>
        <Security UserID="S-1-5-21-XXXXXXXXXXXX" />
      </System>
      <EventData>
        <Data Name="string">C:\Users\TEMP.DOMAIN\AppData\Roaming\Microsoft\Windows\Start Menu\Programs\</Data>
        <Data Name="uint64">6629316385409335299</Data>
      </EventData>
    </Event>
    We noticed thet the user DOMAIN\user had a TEMP.DOMAIN profile path due to faulty permissions on the profile store and that this path thoug its fixed was stil configured in the AppV part registry according to below.
    Since this key is global to the server and not bound to the user account it wasnt removed with the user profile, we tried removing the specific keys manually where the user account UID occured without any change to the problem. The removed keys werent
    regenerated in the registry though.
    The specific user account SID uses TEMP.DOMAIN paths (\Users\TEMP.DOMAIN\AppData\Roaming\Microsoft\AppV\Client\VFS) for two String Value names "TargetLongName" and "TargetShortNamefolders" in the following key (and others):
    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\AppV\MAV\Configuration\Packages\04ADC3E8-E368-4B95-98AF-F53A625070CD_C248B175-B174-41F5-A4D6-62835CF86519\UserConfig\S-1-5-21-XXXXXXXXXX
    As mentioned the UID keys "S-1-5-21-XXXXXXXXXX" did not reappear UNTILL we manually created the folder C:\Users\TEMP.DOMAIN with full permissions for the affected user. Once this folder was created App-V recreated the registry keys "S-1-5-21-XXXXXXXXXX"
    with the correct \Users\USERNAME\* values however the icons for the applications was distributed to the C:\TEMP.DOMAIN\Desktop folder and since the users desktop is accually in C:\Users\USERNAME\Desktop none of the icons was visible to the user.
    Another user had similar issues but with the java plugin for internet explorer failing without error messages, once that user got access to C:\Users\TEMP.DOMAIN the user was again able to run java.

    Cheers,
    Ended up putting in some workarounds.
    Citrix\Microsoft best practice hotfixes
    Review all userprofiles to check correct permissions etc (powershell script)
    Purge Key each week, possibly switch to nightly.
    $CitrixOU
    =Get-ADComputer
    -filter *
    -searchBase 'OU=Citrix,OU=Servers,DC=test'
    | Select-Object
    -expand Name
    Invoke-Command
    -cn $CitrixOU {gci
    HKLM:\SOFTWARE\Microsoft\AppV | foreach-object {gci
    $_.pspath}
    |where-object {$_.name
    -like "*S-1*"}
    |remove-item
    -Recurse -Force}
    until we can work out if this is 'by design'

Maybe you are looking for