I'm looking for a starting point in setting up some kind of link between CME and the NEC. It really doesn't matter if the link is T1 based or IP based. All I really need is to be able to dial from one system to the other and have the calling number show up on caller-id.
The link between NEC & CM is T1 based.
Setup for an end-to-end interoperability with Cisco Unified Communications
Manager Express Release 4.1 connected to the NEC PBX via 2801 T1 QSIG link.
For further information click this link.
http://www.cisco.com/en/US/docs/voice_ip_comm/cucme/pbx/interop/notes/625258nt.pdf
Similar Messages
-
Cisco CME integration with NICE recorder
Hi Team,
Please let me know if we can integrate Cisco CME with NICE recorder. If yes, please share the steps involved in configuration on CME side and NICE.
Warm Regards,
Dinesh RathiHi Anas,
If the panasonic prtocol is H323 will be no problem the CME dial peer will configure as below:-
dial-peer voice 121 voip
translation-profile outgoing prefix
destination-pattern x..
session target ipv4:192.x.x.x
dtmf-relay h245-alphanumeric h245-signal
but if the panasonic protocol is SIP the configuration on CME will be as below:-
voice service voip
ip address trusted list
ipv4 0.0.0.0 0.0.0.0
allow-connections h323 to h323
allow-connections h323 to sip
allow-connections sip to h323
allow-connections sip to sip
supplementary-service h450.12
no supplementary-service sip moved-temporarily
no supplementary-service sip refer
sip
registrar server expires max 250 min 200
no call service stop
dial-peer voice 2000 voip
destination-pattern y...
session protocol sipv2
session target ipv4:172.x.x.x
dtmf-relay sip-notify
codec g711ulaw
no vad
So please can you advise for the above if the two options are right or not??
Thanks -
CCM integration with Mitel SX-2000
We are converting from an Avaya G3si to CCM 4.1(3), and are attempting to move a T1 connection to a Mitel SX-2000. Evidently, the T1 is built as AMI-D4, which I have set up on the gateway page (gateway is MGCP).
We tried to move the cable from Avaya to Cisco 3825 gateway and got no CD. Any idea what the pinouts need to be on this?The Mitel SX-2000 phone system communicates with the Cisco Unity server by using DTMF sequences. The voice messaging lines from the phone system connect to the analog voice cards in the Cisco Unity server. Refer URL
http://www.cisco.com/en/US/products/sw/voicesw/ps2237/products_configuration_guide_chapter09186a008008702a.html#xtocid131812 -
[Fwd: Re: Integration with CM Systems ...]
-------- Original Message --------
Subject: Re: Integration with CM Systems ...
Date: Thu, 10 Aug 2000 15:47:21 -0600
From: Cindy Eldenburg <[email protected]>
Organization: BEA Systems, Inc.
Newsgroups: weblogic.developer.interest.personalization
References: <398f3c55$[email protected]>
Prashanth,
The are a lot of differences in what the Documentum does as compared to
Interwoven Teamsite. Comparing these items is like comparing apples and
oranges.
Normally in Teamsite, during the document capture process, a Teamsite
user
categorizes documents by specifying the documents' metadata attributes
using
Teamsite templates. Once the documents are captured, the Interwoven
OpenDeploy
workflow mechanism is used to publish the content to the WLCS database.
Unlike Interwoven Teamsite, Documentum products manage the metadata and
documents in their own repositories. Thus, with this integration, WLCS
queries
the Documentum system at runtime via a specialized JDBC driver supplied
by
Documentum. Once the Documentum user captures a document and tags it
with
metadata attributes, the document may be immediately available to WLCS
(depending on administrative options in Documentum, such as whether
staging is
involved).
Please contact your sales person for a more detailed overview of what
these two
products do and how they interface to WLPS.
Cindy Eldenburg
Prashanth A wrote:
Can anyone explain to me clearly what does Weblogic mean when it says it
integrated with Interwoven and Documentum. Is there any difference in the
way it interacts with Interwoven as compared to Documentum. As in a run-time
interaction with Documentum whereas a static integration with InterwovenPrashanth,
The are a lot of differences in what the Documentum does as compared to
Interwoven Teamsite. Comparing these items is like comparing apples and
oranges.
Normally in Teamsite, during the document capture process, a Teamsite
user
categorizes documents by specifying the documents' metadata attributes
using
Teamsite templates. Once the documents are captured, the Interwoven
OpenDeploy
workflow mechanism is used to publish the content to the WLCS database.
Unlike Interwoven Teamsite, Documentum products manage the metadata and
documents in their own repositories. Thus, with this integration, WLCS
queries
the Documentum system at runtime via a specialized JDBC driver supplied
by
Documentum. Once the Documentum user captures a document and tags it
with
metadata attributes, the document may be immediately available to WLCS
(depending on administrative options in Documentum, such as whether
staging is
involved).
Please contact your sales person for a more detailed overview of what
these two
products do and how they interface to WLPS.
Cindy Eldenburg
Prashanth A wrote:
Can anyone explain to me clearly what does Weblogic mean when it says it
integrated with Interwoven and Documentum. Is there any difference in the
way it interacts with Interwoven as compared to Documentum. As in a run-time
interaction with Documentum whereas a static integration with Interwoven -
WLC not integrating with Radius Server
Hello world,
I have the following situation:
One WLC 2000 Series (software version 7.0.230.0) with multiple SSID`s, one is with 802.1x integrated with a Radius Server.
Everything worked fine until fiew days ago, when users were unable to logon via they`re certificates on Windows XP.
The infrastracture didn`t suffer modifications.
What i have checked: Radius certification isn`t expired, client certification isn`t expired, the password between controller and Radius is correct.
There are no ACL`s between the WLC and the remote Server. I can ping the devices, other SSIDs on the same controller (wpa/psk) are working correct.
The AP`s are 1242.
I have tried deleting the SSID, configure it back. The OS on Windows Server is 2003 Standard. The AP`s are configured H-Reap.
I have increased the Server Timeout from Radius Authentication Servers from 2 to 30 sec.
The message logs recived on WLC Trap Logs:
RADIUS server X.X.X.X:1812 failed to respond to request (ID 161) for client xx.xx.xx.xx.xx.xx/ user 'unknown'
The message from the debug dot1x aaa enable:
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_CALLING_STATION_ID(31) index=1
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_CALLED_STATION_ID(30) index=2
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_NAS_PORT(5) index=3
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_INT_CISCO_AUDIT_SESSION_ID(7) index=4
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_NAS_IP_ADDRESS(4) index=5
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_NAS_IDENTIFIER(32) index=6
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_VAP_ID(1) index=7
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_SERVICE_TYPE(6) index=8
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_FRAMED_MTU(12) index=9
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_NAS_PORT_TYPE(61) index=10
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_EAP_MESSAGE(79) index=11
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_RAD_STATE(24) index=12
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Adding AAA_ATT_MESS_AUTH(80) index=13
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df AAA EAP Packet created request = 0x1cff348c.. !!!!
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df Sending EAP Attribute (code=2, length=6, id=10) for mobile xx.xx.xx.xx.xx.xx.
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00000000: 02 0a 00 06 0d 00 ......
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.318: 00:15:e9:33:75:df [BE-req] Sending auth request to 'RADIUS' (proto 0x140001)
*radiusTransportThread: Mar 06 09:37:07.328: 00:15:e9:33:75:df [BE-resp] AAA response 'Interim Response'
*radiusTransportThread: Mar 06 09:37:07.328: 00:15:e9:33:75:df [BE-resp] Returning AAA response
*radiusTransportThread: Mar 06 09:37:07.328: 00:15:e9:33:75:df AAA Message 'Interim Response' received for mobile xx.xx.xx.xx.xx.xx.
*Dot1x_NW_MsgTask_7: Mar 06 09:37:07.329: 00:15:e9:33:75:df Skipping AVP (0/27) for mobile xx.xx.xx.xx.xx.xx.
The messages on Windows 2003 Standard:
User Y was denied access.
Fully-Qualified-User-Name = xx.domain.com/Users_T/user
NAS-IP-Address = X.X>X.X
NAS-Identifier = Cisco_
Called-Station-Identifier = ---------------------
Calling-Station-Identifier = ---------------------
Client-Friendly-Name = ---------------------
Client-IP-Address = ---------------------
NAS-Port-Type = Wireless - IEEE 802.11
NAS-Port = 1
Proxy-Policy-Name = Use Windows authentication for all users
Authentication-Provider = Windows
Authentication-Server = <undetermined>
Policy-Name = Wireless Policy
Authentication-Type = EAP
EAP-Type = Smart Card or other certificate
Reason-Code = 262
Reason = The supplied message is incomplete. The signature was not verified.User Y was denied access.
Fully-Qualified-User-Name = xx.domain.com/Users_T/user
NAS-IP-Address = X.X>X.X
NAS-Identifier = Cisco_
Called-Station-Identifier = ---------------------
Calling-Station-Identifier = ---------------------
Client-Friendly-Name = ---------------------
Client-IP-Address = ---------------------
NAS-Port-Type = Wireless - IEEE 802.11
NAS-Port = 1
Proxy-Policy-Name = Use Windows authentication for all users
Authentication-Provider = Windows
Authentication-Server = <undetermined>
Policy-Name = Wireless Policy
Authentication-Type = EAP
EAP-Type = Smart Card or other certificate
Reason-Code = 262
Reason = The supplied message is incomplete. The signature was not verified.
Can anyone help why i cannot log the users via 802.1x ?Okay that is good..... this is what I would do next. I would create a test ssid that uses PEAP MSchapv2 and create a new policy in IAS that is basic. Allow 802.1x wireless and user group only and see if you can reconfigure one of the XP machines for PEAP. Can you also post a screen shot of your polices (connection and network) so we can review it.
-
Siebel new LDAP adapter integration with BI Publisher
Hi All!!
We have configured our Siebel (8.1.1.3) security adapter with LDAP. BI Publisher is using Siebel security model.
We had to clone our AOM (fins_esn which is using the security adapter LDAP) to finsxx_esn because we are migrating the AD 2000 to 2008 (we are also changing the domain). The roll out will last 2 month, users will be migrated by branch, it wont be a big bang.
We have to generate a new LDAP security adapter to authenticate users who are logging to finsxx_esn to the AD 2008 (AD 2008 is on a diferent domain than AD 2000. This is working for application autehtication, no problems found here)
On a standalone environment report generation is working. But for a distributed environment (1 AOM, 1 NAOM, 1 Web Server) is not working.
Does anyone knows how to integrate to BI Publisher when you have two LDAP security adapters on Siebel Application? Or is there any authentication method to use instead of "Siebel Security" so as to achieve this?
RegardsWe actually ran into a similar problem where I work. I created a support web ticket for our issue and the response is that BIP 11G is not supported for integration with Siebel 8.1, or any other version for that matter. Oracle is currently working on a fix to integrated the latest version of Siebel with BIP.
There advice to me was to downgrade to BIP 10G for the time being. -
DPM integration with Microsoft Azure backup queries
Hi All,
We have made the test set-up environment with installed the below details
DPM 2012 R2 on VM (Windows 2012 R2)
We are using a raw disk of 200 GB for disk staging.
DPM integrated with microsoft azure.
Able to take file backup and databases backups from DPM and can perform the restore from Disk staging as well as from azure
Queries:
Will DPM support deduplication for exchange (2007,2010,2013) databases and for sql databases (2000, 2005,2008,2012,2014) ?
on the wire compression is enabled but how to verify that?
Is it possible to mount the raw disk to some other drives except local Disk (C:\)
How to do granular recovery in DPM 2012 R2 for microsoft exchange?Chris,
Really sorry for the delay in response.
I found lots of warning messages in the logs like below one:
578 788 24-Apr 20:49.7 18 readeriterator.cpp(587) [000000002435A140] 0BABF215-19DF-49F5-B8DF-7210CB336DD5 NORMAL
"CFileReaderIterator:GetNextFileReader -> Skipping Hardlink with Physical FilePath: \\?\GLOBALROOT\Device\HarddiskVolumeShadowCopy34\Windows\WinSxS\amd64_microsoft-windows-i..l-keyboard-0001042b_31bf3856ad364e35_6.2.9200.16384_none_f8e4c1f6d2951dd3\KBDARMW.DLL,
Logical FilePath: \\?\Volume{bd3973d0-2f82-11e4-93f6-806e6f6e6963}\Windows\WinSxS\amd64_microsoft-windows-i..l-keyboard-0001042b_31bf3856ad364e35_6.2.9200.16384_none_f8e4c1f6d2951dd3\KBDARMW.DLL"
578 788 24-Apr 20:49.7 18 readeriterator.cpp(587) [000000002435A140] 0BABF215-19DF-49F5-B8DF-7210CB336DD5 NORMAL
"CFileReaderIterator:GetNextFileReader -> Skipping Hardlink with Physical FilePath: \\?\GLOBALROOT\Device\HarddiskVolumeShadowCopy34\Windows\WinSxS\amd64_microsoft-windows-i..l-keyboard-0001042e_31bf3856ad364e35_6.2.9200.16384_none_fa395780d1ba2b68\KBDSOREX.DLL,
Logical FilePath: \\?\Volume{bd3973d0-2f82-11e4-93f6-806e6f6e6963}\Windows\WinSxS\amd64_microsoft-windows-i..l-keyboard-0001042e_31bf3856ad364e35_6.2.9200.16384_none_fa395780d1ba2b68\KBDSOREX.DLL"
So, I'm checking with concerned guys in here about this. I'll get back to you once I receive any update from them. However, if it very urgent and need immediate assistance, I suggest you to open up a support ticket with Azure technical Support team
as they will be able to provide you very quick solution.
Regards,
Manu -
Uc500 integration with ms lync server 2010
Hi,
I’m integrating UC500 with lync server 2000, I’ve achieved to make UC500 users to call lync users and vice versa. But lync users are not able to dial pstn or external numbers through UC500. When I debug UC500 on dialling from lync I can see the incoming call exactly as it should be, its also hitting the correct dial-peer but the call drops and does not go through.
Can you help me on this please?
RegardsHi Muhammad,
Please attach "debug ccsip messages" and "debug ccsip error" output for the failed call together with the UC500 configuration.
If you use ISDN connection to reach PSTN also include "debug isdn q931".
Cheers,
Boris -
XMLP Integration with RightFax
Hi,
Can anyone please point me to any documentation or sample code where I can see how RightFax (3rd Party s/w) can be integrated with XMLP.
The RightFax is running on a Windows 2000 machine.
Thanks.I've only used rightfax from a user perspective. Is it possible to have rightfax either pull from a location or email a file to rightfax? I.e. with our current program, if I email to [email protected] then the program faxes the output to that number.
Brett -
OIM 9.1.0 Integration with Active Directory 2008 R2
Hi,
My customer is running Root/Child AD structure based on windows 2003 w/SP2, OIM 9.1.0 deployed under one of the child domains, and integrated with child domains controllers which runs windows server 2003 as well.
My customer has decided to upgrade his AD to Windows Server 2008 R2 domain controllers across the entire AD Forest and still wants to integrate the current OIM v9.1.0 with AD for all of his Users provisioning and password synchronizations.
Am not sure if current OIM version of OIM 9.1.0 is compatible and supported by OIM v9.1.0 under active directory version 2008 / R2, and not sure if it can be integrated with such AD version.
Any guidance is really appreciated.
Also I was thinking of such scenario but also not sure of its support ability and if OIM will keep working on such scenario, the scenario is to upgrade only the AD root domain to Windows 2008 R2 while keeping the child domain holding the OIM 9.1.0 at Windows 2003 version.
Is this a working and supported scenario by OIM v9.1.0 ?I believe you question should be if the connector supports this architecture. Check out the versions supported for the connector you are using and you should be good.
-Bikash -
Service desk integration with 3rd party tool
Hi all,
I've problems understanding the setup of connecting a 3rd party service desk tool with solman itsm.
So far it's clear that I need to activate and configure the service provider and consumer in soamanager.
The webservice then will be called by the 3rd party tool with corresponding data.
However, according to spro I need to define a value mapping for incoming/outgoing calls.
I do not understand this mapping... the WSDL of webservice ICT_SERVICE_DESK_API contains lots of fields, but in spro -> value mapping I can only define the following fields (which are hard coded in type pool AIICT):
SAPCategory
SAPComponent
SAPDatabase
SAPFrontend
SAPIncidentID
SAPIncidentStatus
SAPInstNo
SAPOperatingSystem
SAPSoftwareComponent
SAPSoftwareComponentPatch
SAPSoftwareComponentRelease
SAPSubject
SAPSystemClient
SAPSystemID
SAPSystemType
SAPUserStatus
What about attachments, priority etc.?
Will the interface parameters mapped to these ones?
For what purpose do I need to maintain the value mapping?
Can you give me a hint?
Regards, Richard Pietschcan you please check the WIKI Solution manager Service Desk Integration with third party service desk - SAP Solution Manager - Security and Authorizat…
-
Java Stack mandatory for a SAP BI system integrated with EP?
Hi Guru's,
Currently we are using SAP NetWeaver 2004 s version 7.0 system for our BI.
This is integrated with the EP. But our BI system does not contain the Java Stack installed.
When we work on WAD templates and execute the template, it is automatically directed to EP portal where we can see our reports.
Here my question is do we need Java Stack for this system to use ADOBE DOCUMENT services or can it work with EP only for the web functionalities.
Any info on this is of great help.
Best Regards
KumarHI Reddy,
We came to know from our basis team that we do not have the Java Stack installed in our BI 7.x system yet.
As it is integrated with EP which has Java, our web reports are working.
1) But my question is still do we ned to install the Java Stack in our BI system as i do not find any Export to PDF option in EP for the reports (eventhough AS Java supports this).
2) Or can we use the existing configuration without Java STack integrated to EP for the new tools like Report Designer and Integrated Planning?
Regards
Kumar -
Session keep Alive when EBS is integrated with OIF acting as SP
We have an E-Business Suite R12(12.1.3) Application which is integrated with Oracle Access Manager 11.1.1.5. For authentication the Oracle Access Manager delegates the authentication request to Oracle Identity Federation acting as a Service Provider (SP). There is a home-grown SSO which acts as the Identity provider by Federating it with OIF using SAML 2.0 protocol.
The integration is successful and EBS is able to authenticate using this third party SSO.
Now there are multiple applications which are integrated with this third party SSO and the user can access any of these applications including EBS.
Considering a scenario where a user is using EBS Application say for more than 30 mins. Now when he tries to login to another application the challenge screen is thrown though he can continue to work on EBS without any issue. The reason being that the session timeout on the IDP side is set to 30 mins.
To overcome this issue the solution that has been thought of using a javascript for each page load on the application which will update the SSO token with the latest UTC time on the IDP server. This has been successfully done for all other applications except EBS.
So my question is how we can call this java script for each page load for EBS?
Thanks & Regards
SarbashisIt appears that OAM is removing the url parameters for the p_done_url sent to it by OIF.
302 Redirect to -> Location: https://sso.mycompany.com/oam/server/logout?p_done_url=https%3A%2F%2Fsso.mycompany.com%2Ffed%2Fuser%2Fsloosso%3Fid%3Dosso%26type%3D3&invokeOSFSLogout=false
Result: 200. Set-Cookie OAM-ID to expired.
Form Submits: https://sso.mycompany.com/fed/user/sloosso
Result: 500 Error
Notice the p_done_url value in the redirect has extra parameters which when the Form is submitted are lost.
If I manually enter the url: https://sso.mycompany.com/fed/user/sloosso?id=osso&type=3&invokeOSFSLogout=false
Then I am successfully logged out.
This seems almost like a bug in OAM... -
RE: Legacy Integration with PI/Open
Greg -
We are currently working on wrappering the APIs for UniVerse (aka Pick on
UNIX).
We received some help from the guys at RTD in Denver.
We tested out a C program that uses the Universe APIs and it works fine.
We will be building the Forte piece and compiling it this week.
Our first application is to inquire the UniVerse data, after that is
successful, we will move to inserting & updating.
Let us know how we can help.
Larry McCartney
[email protected]
(203)459-7959 - Trumbull
From:
[email protected][SMTP:[email protected]
om]
Sent: Monday, October 12, 1998 11:00 AM
To: [email protected]
Subject: forte-users-digest V1 #1111
forte-users-digest Monday, 12 October 1998 Volume 01 : Number
1111
In this issue:
Legacy Integration with PI/Open
is OBB32.dll available
Java Integration
Java Integration
Re: Legacy Integration with PI/Open
RE: Forms That Will Not Close
RE: Forms That Will Not Close
RE: Forms That Will Not Close
Re: AfterValueChange event trigged when it shouldn't be...
math library
From: [email protected]
Date: Mon, 12 Oct 1998 09:49:56 +1000
Subject: Legacy Integration with PI/Open
This is a bit of a long shot, but has anyone experience with integrating
Forte with PI/Open. PI/Open is a variant of PICK. We have a requirement
to read and update a PI/Open database from within our Forte application,
and we would be most interested to hear from anyone who has experience in
doing this.
We are aware of a set of APIs provided with PI/Open that are written in
"C". We could wrapper these from within Forte, however the issue is that
the APIs provided are non-shared, and Forte requires shared libraries.
Thanks in advance for any help.
Greg Barber.
The information transmitted is intended only for the person or entity to
which it is addressed and may contain confidential and/or privileged
material. Any review, retransmission, dissemination or other use of, or
taking of any action in reliance upon, this information by persons or
entities other than the intended recipient is prohibited. If you
received
this in error, please contact the sender and delete the material from any
computer.
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: "sridhar t" <[email protected]>
Date: Sun, 11 Oct 1998 22:01:36 PDT
Subject: is OBB32.dll available
hi,
am working on forte3.0.G.2. when i tried to use objectbroker library i
am unable to find the runtime objectbroker library (OBB32.dll). is this
dll available with this version. if not is there any alternative.
thanks,
sridhar,
Goldstone Softech USA
Get Your Private, Free Email at http://www.hotmail.com
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: srinivasa gopi <[email protected]>
Date: Sun, 11 Oct 1998 23:12:22 -0700 (PDT)
Subject: Java Integration
Hello,
I'm trying to integrate Forti with Java in Java mode using IIOP.I
followed the steps as explained in the Forti Web enterprise manual.I
compiled the Java files that are generated by Forti along with the
client Java file.The Java applet is getting downloaded on the client
browser(IE 4.0), but the problem is browser is giving an exception
** Java.lang.RuntimeException can't connect to service object with
the ior file name **.
My question is on every client is it necessary for ORB(Visigenic for
Java 3.2) and also the Forti Java interoperability package that is
provided by the Forti for compatability with Java or it is not
required on the clients ?
Is there any other alternative to achieve the goal as this will give
wide access to the Forti service objects through Web Browser clients.
Please mail me the solution to this problem as early as possible it is
very urgent.
Thanks in advance,
Srinivasa Gopi,
Goldstone Softech USA
DO YOU YAHOO!?
Get your free @yahoo.com address at http://mail.yahoo.com
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: srinivasa gopi <[email protected]>
Date: Sun, 11 Oct 1998 23:26:26 -0700 (PDT)
Subject: Java Integration
Hello,
I'm trying to integrate Forti with Java in Java mode using IIOP.I
followed the steps as explained in the Forti Web enterprise manual.I
compiled the Java files that are generated by Forti along with the
client Java file.The Java applet is getting downloaded on the client
browser(IE 4.0), but the problem is browser is giving an exception
** Java.lang.RuntimeException can't connect to service object with
the ior file name **.
My question is on every client is it necessary for ORB(Visigenic for
Java 3.2) and also the Forti Java interoperability package that is
provided by the Forti for compatability with Java or it is not
required on the clients ?
Is there any other alternative to achieve the goal as this will give
wide access to the Forti service objects through Web Browser clients.
Please mail me the solution to this problem as early as possible it is
very urgent.
Thanks in advance,
Srinivasa Gopi,
Goldstone Softech USA
DO YOU YAHOO!?
Get your free @yahoo.com address at http://mail.yahoo.com
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: Tim Hagemann <[email protected]>
Date: Mon, 12 Oct 1998 09:21:06 +0200
Subject: Re: Legacy Integration with PI/Open
Greg,
This is a bit of a long shot, but has anyone experience with integrating
Forte with PI/Open. PI/Open is a variant of PICK. We have arequirement
to read and update a PI/Open database from within our Forte application,
and we would be most interested to hear from anyone who has experiencein
doing this.
We are aware of a set of APIs provided with PI/Open that are written in
"C". We could wrapper these from within Forte, however the issue isthat
the APIs provided are non-shared, and Forte requires shared libraries.Would be interersting, which operating system you're using.
You could write a dll (on windows) or shared library (on unix) wrappering
the
original,statically linked "C"-Libs. This lib could be used by Forte.
Tim Hagemann
Tim Hagemann
Ascom GmbH Email: [email protected]
Charlottenburger Allee 61 Phone: +49 241 96806 273
D-52068 Aachen Fax: +49 241 96806 225
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: "Rottier, Pascal" <[email protected]>
Date: Mon, 12 Oct 1998 09:38:25 +0200
Subject: RE: Forms That Will Not Close
Exiting the event loop will not close the window! Invoking
'Close' method on the window will. Check if this method
is executed. It appears, the AfterFinalize event exits the
event loop and nothing more. Then, your applications
waits for some event from your main window, like 'Mouse-
Enter', before invoking Window.Close().
Pascal
Hi,
We seem to be having some type of deadlock problem when trying to
close
forms and am wondering if anyone else has experienced this problem.
The
phenomenon does not always occur and is not specific to any one client
machine.
I will explain the phenomenon:
1. We have an object that contains our main application startup
method.
This method then instantiates our main application window (Control)
and
invokes the Display() method using start task.
2. All other forms created by the application are created using a form
manager service object which exists on the client partition. The form
manager has a CreateForm() method which instantiates a form class of
the
specified type and invoked the form's Display() method using start
task.
3. Each form has a Close push button which when clicked invokes
Window.RequestFinalize().
Now, the problem we have is this:
The user starts the application and the main application window is
displayed. The user then selects an option from the main window and a
child form is created using the form manager service object and is
displayed. The user can continue to create more child forms by
selecting
options from the main window and all child forms are instantiated and
displayed correctly.
However, when the user attempts to close one of the forms the form
does
not close. The finalize event is triggered and the event loop is
exited,
but the form continues to be displayed and does not close. If the user
then moves the mouse pointer over the main application window, the
child
form immediately closes. Moving the mouse cursor over other child
windows (or even the desktop) does NOT do this - only when the mouse
cursor is moved over the main window does the child form close.
Does anyone have any ideas on this?
Regards,
Jace.
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive
<URL:http://pinehurst.sageit.com/listarchive/>- -
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: Jason de Cean <[email protected]>
Date: Mon, 12 Oct 1998 17:47:20 +1000
Subject: RE: Forms That Will Not Close
Hi Pascal,
The Display() method is as follows:
self.Open();
event loop
when Window.AfterFinalize do
exit;
when task.Shutdown do
exit;
end event;
self.Close();
<end>
Are you saying we should do a Window.Close() in there somewhere as well
Regards,
Jace.
On Monday, 12 October 1998 17:36, Rottier, Pascal
[SMTP:[email protected]] wrote:
Exiting the event loop will not close the window!
Invoking
'Close' method on the window will. Check if this method
is executed. It appears, the AfterFinalize event exits
the
event loop and nothing more. Then, your applications
waits for some event from your main window, like 'Mouse-
Enter', before invoking Window.Close().
Pascal
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: "Rottier, Pascal" <[email protected]>
Date: Mon, 12 Oct 1998 11:04:24 +0200
Subject: RE: Forms That Will Not Close
Jason,
No, self.Close() should close the window. This is the
method I referred to. You could place a traceline
behind self.Close() to see if it is executed. It is not
inconcievable some exception may exit the Display()
method before self.Close() is executed.
After that, maybe, some events from your main
window trigger something that causes a call like 'My-
Window.Close()', where 'MyWindow' is a subclass of
'UserWindow', so 'MyWindow' gets closed after all.
Maybe you've overridden 'Close()', so now it doesn't
work properly anymore.
Are you sure you exit the event loop after you press
the close button?? The display method is not regis-
terred for any <PushButton>.Click event, though maybe
you just didn't include the full Display method in your
mail.
Remember that an event loop will only respond to an
event if it is not currently handling an event. So, the
method behind <PushButton>.Click may call a self.
Window.RequestFinalize(), which will cause an After-
Finalize event to be posted, which will be placed in
the event queue. If this method however keeps waiting
for something, the event loop will not respond to the
AfterFinalize event, until this method is done waiting.
Pascal.
Hi Pascal,
The Display() method is as follows:
self.Open();
event loop
when Window.AfterFinalize do
exit;
when task.Shutdown do
exit;
end event;
self.Close();
<end>
Are you saying we should do a Window.Close() in there somewhere as
well
Regards,
Jace.
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: Thomas Kunst <[email protected]>
Date: Mon, 12 Oct 1998 14:28:55 +0200
Subject: Re: AfterValueChange event trigged when it shouldn't be...
Which version of Fort=E9 are you using? We had some strage problems with
GUI events in Fort=E9 3.0.F.2, which disappeared now that we use 3.0.J.1!=
Fouche, Jaco wrote:
=
Hi there,
=
I'm hoping that someone out there has experienced the following (and
knows why it is happening. ) :-)
=
I have a couple of windows on which the AfterValueChange event is
triggered on a field upon hitting the delete key.
We all know that this should only happen upon leaving the field, ie. th=e
field loosing focus. The problem is that I'm trying to recreate this in=
a simple test class, but now it won't happen. I still have the original=
windows on which it is happening, but I would like to construct
something small and simple to send to Forte.
=
Any ideas as to why this could be happening?
=- -- =
Dr. Thomas Kunst mailto:[email protected]
sd&m GmbH & Co. KG http://www.sdm.de
software design & management
Thomas-Dehler-Str. 27, 81737 Muenchen, Germany
Tel +49 89 63812-221 Fax -444
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
From: Greg Gorham <[email protected]>
Date: Mon, 12 Oct 1998 09:51:07 -0400
Subject: math library
I need direction to the source of Forte libs that handle more scientific
math. Also included is the need for more scientific print formating. I
understand, second hand, that such material is available from third
party vendors/sources.
Thanks
Greg Gorham
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>
End of forte-users-digest V1 #1111
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/>Greg,
This is a bit of a long shot, but has anyone experience with integrating
Forte with PI/Open. PI/Open is a variant of PICK. We have a requirement
to read and update a PI/Open database from within our Forte application,
and we would be most interested to hear from anyone who has experience in
doing this.
We are aware of a set of APIs provided with PI/Open that are written in
"C". We could wrapper these from within Forte, however the issue is that
the APIs provided are non-shared, and Forte requires shared libraries.Would be interersting, which operating system you're using.
You could write a dll (on windows) or shared library (on unix) wrappering the
original,statically linked "C"-Libs. This lib could be used by Forte.
Tim Hagemann
Tim Hagemann
Ascom GmbH Email: [email protected]
Charlottenburger Allee 61 Phone: +49 241 96806 273
D-52068 Aachen Fax: +49 241 96806 225
To unsubscribe, email '[email protected]' with
'unsubscribe forte-users' as the body of the message.
Searchable thread archive <URL:http://pinehurst.sageit.com/listarchive/> -
Excel integration with Entry and Approval for SSM not working
Iu2019m having trouble getting excel integrated with E&A for being able to enter large number of historic data points into a cube-built model u2013 Iu2019ve gone through all the docs several times and there is no good concrete explanation on how to do this. I keep getting the following error message:
Error opening Excel Automation server can't create object. This can be caused by:
1. - The application is not installed on your machine
2. - The browser security does not support ActiveX scripts.
3. - Your were prompted to run ActiveX and you said No, if that is the cause close all browser instances and reopen.
However, I've done the following:
- Iu2019ve installed the excel add-in on both the server and my local machine, and Iu2019ve enabled the add-in part in Excel on my local machine.
- The browser security is definitely set to accept all active X scripts
- I am never prompted to run activeX when I select u201CHistorical Datau201D within entry/approval. I just get the above error message.
- Iu2019ve flushed cache and restarted listener several times.
What am I missing? I donu2019t see it in any of the docs.
Thanks!Robb,
Looking at what you've done, there doesn't seem to be an obvious answer. The best suggestion I can make is to fill out a support ticket on this. There must be other factors at work here that will require a deeper look.
Regards,
Bob
Maybe you are looking for
-
Order Data Ware House SD report?
Hi all kindly give a solution for this scenario If there are no quantity on the request, it will not show a u201C0u201D order quantity there u2013 it will show the first promise quantity by its side and show the promised quantity there. Please cha
-
No Sound in QuickTime when Slideshow Exported from iPhoto
I'm currently using iPhoto 2.0.1 and QuickTime Player 7.1.3. When I export a slideshow from iPhoto to QuickTime, a '.mov' file is created. When I play it, I can view the slideshow but there's no sound. Does anyone know why? Here's how I export a slid
-
File Browse column in Report (Detail of Master Detail)
Is it possible for a column in my report of my detail (in master detail) to be a file browse type? The option isn't there for the column type and I cant find any htmldb_item.file_browse type of thing (like you can create checkbox in report using this
-
Hi all, I am using cl_salv_table to get alv list. but i want to limit the field columns in the final output, since we so not pass any fieldcat in this method , so please tell me how to limit the field in the output. regards, kushagr
-
Runtime Error: java.lang.ClassCastException
My project is to creat a postfix with boolean. I finished my code, it compiled great, than I got an java.lang.ClassCastException. So obviously I have a casting problem. Any help or hints in the right direction would be greatly appreciated. impor