CMOS Errors/ battery failure in a Satellite L45

I have a Satellite L45-S7423 laptop that is approximately 1.5 yrs old.  To give a bit of history on this baby..a week before the warranty ran out, the computer stopped working so we took it in to be repaired and it got a new motherboard and I believe power supply.  
Fast forward 6 months to now, and as of last night I have started getting a black screen on boot up that goes to American Megatrends.  There are a bunch of self checks (I assume thats what they are) check out as ok and then it beeps, and goes to a second page where at the bottom it says "CMOS battery low, and something about the date and time not being set.  I have options for F1 to load defaults and F2 to enter set up.  Pressing F1 loads Vista properly.   The computer now thinks it is permanently March 4 2008...but the time runs as you would expect.  It just is in accordance to either 11:00 or 12:00 when I reboot.  
I have noticed today after the reboot, that my antivirus vault settings have now been lost and I also started having issues with opening websites (security certificates not valid so it says or it completely blocks a regularly used site from opening).  Since the AV isnt working properly anymore I disconnected from the wireless network I use and turned off the wireless capability.
I run this computer almost non-stop, it has a chill pad after the October issue, and is updated regularly.  I do run down the main battery at least once or twice a week and recharge it completely.  Most of the time the laptop is on AC power though.  This issue came up after it was unplugged during house chores and my husband and I both forgot to plug it back in.  At most it was unplugged for a little over 2 hours.   I plugged it back in for 24 hours, and the most recent reboot still brings up the CMOS message.  There was an SD memory card in the card reader when I rebooted which I had forgotten about.  The only other oddity is that these problems started after a windows update ran on 3/13. 
What can I do for this?  Is it something I can fix by replacing the CMOS battery? It is NOT under the main battery where it was suggested to me that it might be....does this mean its on the motherboard?  If I press f2 for set up, what will happen? I also have a prompt to press f12 for BBS POPUP.  Thanks for your help and time.  
Solved!
Go to Solution.

OK, I attempted to disassemble the laptop following the "destructions" that were provided in an earlier post.   This portion of the project went extremely well...the directions were really easy to follow.  
The bad news is as follows....  I found the CMOS battery.  Either Toshiba, or the manufacturer of the mother board, american megatrends, soldered the stupid thing to the friggin motherboard.  I realized that this is above and beyond my level of skill, so I ran down the street to a small computer repair shop nearby and swallowed what little pride I have left.   I asked them if in fact my suspicions were correct in that the CMOS battery is soldered to the motherboard and they looked at it and went....EWWWW.  
I truly appreciate their honesty b/c they wont even touch this because they do not want to fry the motherboard.  They reccommend that I contact Toshiba at this point.  I will keep these folks in mind if I need computer repair work done in the next few years...
The experience was not a total loss to me though, because I now have a very good working knowledge of what different things look like in the laptop.  Even better, I put it back together and everything that did work, still works...haha.   One thing I did notice is that the repair place failed to replace all the screws...
I appreciate all the advice.  I did try taking the laptop battery out and running the computer for several days on just AC power...in 5 days it went from March 4, 2008 to March 6, 2008.   I will post an update when I hear from Toshiba...

Similar Messages

  • Premature CMOS 2032 Battery Failures

    There have been many reports in this forum lately concerning premature CMOS 2032 battery failures.
    If there truly is a common CMOS battery problem with MSI systemboards
    we need to start to find the solution by identifing what vendors battery is failing and on what boards.
    My mobo is MSI K8N Neo4 Platinum (G52-M7125X1)
    My original CMOS battery was a KTS Lithium CR2032
    It lasted about 1 month then the systemboard failed to POST.
    I replaced it with a Energizer Lithium 2032
    It has worked for a week so far.
    The 2032 is a Lithium-Manganize Dioxide 3.0 Volt Button Battery.
    It is designed not for recharging.
    Life expectancy is least 2 to 4 years
    A new 2032 battery unused and right out of the package measures 3.26Volts DC.
    The new 2032 battery in the motherboard with AC power on, measures 2.97 Volts DC.
    A defective KTS CR2032 battery out of the motherboard for days measures 2.97 Volts DC.
    A defective KTS CR2032 battery in the motherboard with AC power on measures 1.41 Volts DC.
    I used a Fluke Series 77 Digital Multimeter for the measurements.
    My Phoenix-Award BIOS Version 1.4 - PC Health Status of the good Battery = 1.66 Volts
    I have no idea what that means other than the BIOS is not reporting accurate battery voltages.
    If you just have to know all there is to know about batteries try these sites:
    http://www.buchmann.ca/
    Energizer Lithium Photo/Coin Application Manual
    http://data.energizer.com/PDFs/lithiumcoin_appman.pdf
    Energizer Lithium-Manganese Dioxide Battery Datasheet
    http://data.energizer.com/PDFs/lithiummangdioxide_psds.pdf
    Hope this helps...
    Bob...

    Here are some of the Forum's references to CMOS Battery failures...
    Please post results of any correspondence with MSI Tech Support concerning this problem so we can share the info.
    mbga9pgf
    https://forum-en.msi.com/index.php?action=profile;u=68466
    mbga9pgf
    https://forum-en.msi.com/index.php?action=profile;u=67074
    tarheel
    https://forum-en.msi.com/index.php?action=profile;u=65599
    Heresy
    https://forum-en.msi.com/index.php?action=profile;u=68531
    tarheel
    https://forum-en.msi.com/index.php?action=profile;u=65599
    DolphinBay
    https://forum-en.msi.com/index.php?action=profile;u=68451
    Supershanks
    https://forum-en.msi.com/index.php?action=profile;u=48465
    Bob...

  • Sticky: Bios & Startup Issues - Premature CMOS 2032 Battery Failures

    Symtoms:-
    Quote
    DolphinBay
    I am unable to save any BIOS updates.  I have tried to update the BIOS to v1.4, only to have the same problem.  If I make any changes to the BIOS information, the system will either A) Hang on F10/Save Changes, or B) if it does Re-POST the information, ALL of my changes are lost.
    Neo4 Platinum (7125) BIOS Issues - BIOS Won't Save Changes 
    tarheel  - System worked fine for two weeks then one morning - NO Boot. No Beep just the four red LED's on the D-Bracket
    Solution:-
    Quote
    tarheel
    If you haven't already done so please replace the CMOS battery asap. Then let us know how it works. I have had similar problems and the battery is the secret.
    See also Premature CMOS 2032 Battery Failures  The reason for the failures is unknown at the minute.

    Here are some of the Forum's references to CMOS Battery failures...
    Please post results of any correspondence with MSI Tech Support concerning this problem so we can share the info.
    mbga9pgf
    https://forum-en.msi.com/index.php?action=profile;u=68466
    mbga9pgf
    https://forum-en.msi.com/index.php?action=profile;u=67074
    tarheel
    https://forum-en.msi.com/index.php?action=profile;u=65599
    Heresy
    https://forum-en.msi.com/index.php?action=profile;u=68531
    tarheel
    https://forum-en.msi.com/index.php?action=profile;u=65599
    DolphinBay
    https://forum-en.msi.com/index.php?action=profile;u=68451
    Supershanks
    https://forum-en.msi.com/index.php?action=profile;u=48465
    Bob...

  • Re: Premature CMOS 2032 Battery Failures

    Hi,
    I have the problem with the CR2032 batteries dying on alot of 7F2WE 1G5D-OC-LF motherboards from Jetway.  Has anyone seen that?
    I measured and replaced batteries on the units a week ago.  The all read 3.25V to 3.3V.  I checked them all today and they were between 1.5V and 2.9V.  This is a serious problem for me since the product I make uses this motherboard and depends on the CMOS settings.  There seems to be no way for me to garantee that my product will actually work when it gets to the customer
    Don

     I would suggest you go to Jetway with your problem. This not a general forum and is for MSI products.

  • CMOS Battery Failured

    Hello,
    I'm having a problem with the PXI-8170 Controller, the system does not start due the CMOS Battery Failured. I'm attaching a image with the error.
    If I press F1 to continue, the system does not start and stays in black screen.
    Thanks.
    J. Frantz
    Attachments:
    erro.jpg ‏2025 KB

    Hello lferreira,
    Thanks for the reply.
    Yesterday I found the battery on the PXI processor, it's a Timekeeper M4T28-BR12SH1, DataSheet here . I will try to change the battery, first i need to buy it.
    I found a supplier here in Brazil.
    Thanks.
    Julio
    Attachments:
    20140428_151333.jpg ‏1827 KB

  • Possible CMOS Battery problem with my Satellite 1405-s151

    I have a satellite 1405-s151. Since July it won't start. when i turn it on the green lignts is on but nothing else happens. however it sometimes starts with a bad checksum (ROM) or Cmos error.
    someone told me that it could be a dead the cmos battery.
    what u think about this ? i live in senegal and there is no toshiba center

    Hi
    I don't think this is a problem with the CMOS-battery. If it is defective or has a low voltage, the machine will give this error message, BUT it will never have a problem booting up because of it. A defective battery will make the system lose track of time and date and possibly some settings You might have made in the SETUP but when the unit starts and gives the error message (You have to press F1-key to continue) the default settings will be set and they are good enough to make the system boot. I suggest You remove any hardware You might have added to the unit (memory, PC Cards and so on) and try again. If it still fails then I think Your machine is defective and need service.
    best regards
    Tom

  • CMOS / RTC Battery for Satellite A100-326?

    Hi,
    I'm after a replacement CMOS/RTC battery for my A100-326
    I've got my machine open and located the battery but it has no model number on it.
    I have contacted a Toshiba assistance center and they replied that the battery is part of the board and the whole board has to be replaced. However, if I can find the reference for the battery, I have a friend in a computer store that will replace it with a new one.
    Any help would be great. Thanks!
    Regards
    Srgio

    Hi
    Why you want to replace this
    Such battery is reachable
    To charge the RTC battery you have to connect the AC adaptor to the notebook.
    The main battery should be inserted too and the notebook should run for 20.24 hours.
    Anyway, as far as I know its a Lithium Ion RTC battery 3V and 14mAh

  • PXI 8156B Battery Failure and restore harddrive.

    Hi,
    I am working on restoring a very old system built using PXI8156B, attached are the snaps.
    The system has damaged OS. I want to restore by ghost image which was captured just before final system was ready for operation.
    The CPU module has battery failure which cause "Loading defaults" thereby booting from C. I tried making boot sequence "A,C" but was no success.
    I would like to know how do I restore the battery..? There doesn't seem removable battery.
    How can I restore the ghost image if battery solution fails..?
    Kindly advice.
    Thanks and regards,
    Kunal
    Attachments:
    DSC_0402.jpg ‏1824 KB
    DSC_0403.jpg ‏2300 KB

    Calle:
    I would like to erase a partition that I have on my 30gb internal harddrive.
    Do you have more than one partition on the HDD? I suspect you have only one since the HDD is only 30 GB.
    Your computer is now 8 years old, as is the original HDD. The average life of these drives is 3 to 5 years, so your HDD is well past old age. You may be getting the error messages because your drive is failing.
    cornelius

  • FRM-41211 Integration error SSL failure

    Hello
    Environment Client/Server Developer 6i.
    i installed developer on a new clinet machine to rum my application. every thing is fine but when he tries to run any report the following error occured:-
    FRM-41211 Integrarion error SSL failure runing another product.
    and i have re-install the devloper but the error is stand.
    any solution?
    regards
    aaks

    As Petr said make sure you're reports25_tmp is set in your registry and that the directory exists AND you have the rights to write to that directory.
    You can also get this error if you try to issue a 2nd asynchronous run_product call to run a report and there is another one running. For this, Oracle has two 'solutions'.
    1) Do not run more then one asynchronous report per session
    or
    2) Use a delay loop before calling the next report.
    It's been my experience that #2 is worthless as, if it works, is doing pretty much the same thing as #1. I really hope this gets fixed (for good) at some point...somehow. <G>
    Chad

  • FRM-41211: Integration Error: SSL failure running another product Error

    Hai,
    I am developing POS Application in Oracle(Forms6i/Reports6i). I design the Invoice Print Format in Reports6i and call from the Invoice Form. When the
    user save the Invoice I Commit the Invoice and call the Invoice Report for Printing Immediately. I use Epson TM U210B Label Printer for Billing. Sometimes the Invoice Print is not coming in the Printer and it gives the
    following error(especially the First print after restart the computer).
    FRM-41211: Integration Error: SSL failure running
    another product
    After that if you print further for transaction no plm. only it gives the error first time of print
    So Please give the solutions immediately. I am waiting for Ur favourable Reply.
    Ur's Shahul

    As Petr said make sure you're reports25_tmp is set in your registry and that the directory exists AND you have the rights to write to that directory.
    You can also get this error if you try to issue a 2nd asynchronous run_product call to run a report and there is another one running. For this, Oracle has two 'solutions'.
    1) Do not run more then one asynchronous report per session
    or
    2) Use a delay loop before calling the next report.
    It's been my experience that #2 is worthless as, if it works, is doing pretty much the same thing as #1. I really hope this gets fixed (for good) at some point...somehow. <G>
    Chad

  • Run report --- Integration Error ----SSL failure

    I have a form that call a report through the Run_Product Built, this works fine on Developer 6 version, but after I upgraded to 6i, everytime I press the buttonn that call the report, an error message will appear that say "FRM-41211 Integration Error SSL failure running another product" after the Report Background Engine appeared. And the report will not start.
    But if I press the button again, all will be fine.
    Does anyone know what happens ?
    PLease help!!!!

    It is a bug in Forms 6i and possible workaround (from Metalink) is:
    WORKAROUND as follows :
    This brings up the Background Engine on startup and minimizes it.
    1. Create a shortcut for rwrbe60.exe and do a CTRL+C to copy it.
    2. Right click on the TASK BAR at the bottom of the screen and get the TASKBAR
    Properties box up.
    3. Select ADVANCED
    4. Expand Tree for PROGRAMS.
    5. Click of STARTUP folder.
    6. Do a CTRL+V to Paste in the Shortcut to rwrbe60.exe.
    7. Right Click on Shortcut and select Properties.
    8. Click Shortcut Tab.
    9. Make sure of the following fields are as follows:
    TARGET : {drive}:\{path}\rwrbe60.exe /c
    START IN : Is the location of your Reports and Forms.
    SHORTCUT KEY : None
    RUN : MINIMIZED

  • Integration error SSL failure running another product. - Urgent

    Anybody knows what could be the possible problem and how to solve it. This error is coming when I am running RUN_PRODUCT built-in forms 6i, that application was running for 2 years in Forms 5, without any problem.
    I have included the message what Forms doucmentaion had.
    FRM-41211: Integration error: SSL failure running another product.
    Cause: There is a problem detected when launching another product.
    Action: Check the RUN_PRODUCT built-in.
    Level: 99
    Type: Error
    null

    I got this error when I was using 4.5, it may be caused by the
    correctness of report_path in registry.
    Regards,
    George
    Anybody knows what could be the possible problem and how to solve it. This error is coming when I am running RUN_PRODUCT
    built-in forms 6i, that application was running for 2 years in
    Forms 5, without any problem.>I have included the message what
    Forms doucmentaion had.>FRM-41211: Integration error: SSL
    failure running another product.>Cause: There is a problem
    detected when launching another product. >Action: Check the
    RUN_PRODUCT built-in. >Level: 99 >Type: Error >null

  • Integration error SSL failure running another product

    Dear All,
    I am facing some problem while running reports from forms
    SERVER:
    •     OPERATING SYSTEM: Windows.8
    •     Database: ORACLE 11g
    •     Forms & Reports = 6i.
    In form when click any report button to call report some time error comes.
    FRM-41211: integration error SSL failure running another productAnd user can not print the report,

    Forms/Reports 6i on Windows 8? I very much doubt that this is going to work. The last supported OS for Forms/Reports 6i was Windows XP.
    You might have some luck with a non-supported workaround:
    http://windows7bugs.wordpress.com/2012/08/25/windows-8-oracle-developer-suite-6i-patch-18/

  • Integration Error:SSL failure running another product.In DeveloperSuite 10g

    I'm using DeveloperSuite 10g. I'm trying run the report from Forms but when I'm
    clicking on button to run report using RUN_REPORT_OBJECT I'm getting following
    error :
    Integration Error : SSL failure running another product.
    Can any one explain why I'm getting this error.
    Regards
    Alpesh.

    Hi alpesh
    I think you are good at oracleDS 10g and it is running on your machine successfully. But I am not able to run any form on my system.
    My OS is Win XP with service Pack 2
    Installed Oracle Database 10g
    Installed Oracle DS 10g
    Able to run reports on paper layout and web layout, But can not run forms. Error is shown on the IE Ver 7. Only source code is displayed. can you help me out from this.

  • Error : FRM-41211 : Integration Error: SSL Failure Running Another Product

    Hi All
    I am using Forms & Reports 10g.
    I have a report .And i am trying to call in my forms and also i am passing parameters.
    But i am getting this error :
    My Code is :-
    DECLARE
    repid REPORT_OBJECT;
    v_rep VARCHAR2(100);
    rep_status VARCHAR2(20);
    plid ParamList;
    vParamValue number;
    BEGIN
    plid := Get_parameter_List('tmp');
    IF NOT Id_Null(plid) THEN
    Destroy_parameter_List( plid );
    END IF;
    plid := Create_parameter_List('tmp');
    Add_Parameter(PLid, 'P_Block', Text_Parameter, :block_query.item_block);
    Add_Parameter(PLid, 'P_Category', Text_Parameter, :block_query.item_category);
    Add_Parameter(PLid, 'P_Dept', Text_Parameter, :block_query.item_dept);
    Add_Parameter(PLid, 'P_Floor', Text_Parameter, :block_query.item_floor);
    Add_Parameter(PLid, 'P_IP', Text_Parameter, :block_query.item_ip);
    Add_Parameter(PLid, 'P_Room', Text_Parameter, :block_query.item_room);
    Add_Parameter(PLid, 'P_Userid', Text_Parameter, :block_query.item_usr_id);
    Add_Parameter(PLid, 'PARAMFORM', Text_Parameter, 'NO');
    repid := FIND_REPORT_OBJECT('REPORT_Query');
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_COMM_MODE,SYNCHRONOUS);
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_DESTYPE,cache);
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_DESFORMAT,'PDF');
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_OTHER, 'paramform=no');
    v_rep := RUN_REPORT_OBJECT(repid,plid);
    rep_status := REPORT_OBJECT_STATUS(v_rep);
    WHILE rep_status in ('RUNNING','OPENING_REPORT','ENQUEUED')
    LOOP
    rep_status := report_object_status(v_rep);
    END LOOP;
    WEB.SHOW_DOCUMENT('http://A_F2_ITT_PC_4.AAHOS.LOCAL:8890/reports/rwservlet/getjobid'||substr(v_rep,instr(v_rep,'_',-1)+1)||'?
    *'||'server=Report_server_name&P_parameter='||'&block='''||:block_query.item_block*
    *||'&category_name='''||:block_query.item_category*
    *||'&dept='''||:block_query.item_dept*
    *||'&floor='''||:block_query.item_floor*
    *||'&ip_address='''||:block_query.item_ip*
    *||'&room='''||:block_query.item_room*
    *||'&usr_id='''||:block_query.item_usr_id*
    *||'&paramform=no');*
    End;
    And the error i am getting is :- FRM-41211 : Integration Error: SSL Failure Running Another Product

    hi
    please try something like this.
    DECLARE
    repid REPORT_OBJECT;
    v_rep VARCHAR2(100);
    rep_status VARCHAR2(20);
    plid ParamList;
    vParamValue number;
    BEGIN
    plid := Get_parameter_List('tmp');
    IF NOT Id_Null(plid) THEN
    Destroy_parameter_List( plid );
    END IF;
    plid := Create_parameter_List('tmp');
    add_parameter(plid,'p_parameter',text_parameter,to_char(:block.item));
    Add_parameter(plid, 'PARAMFORM', TEXT_parameter, 'NO');
    repid := FIND_REPORT_OBJECT('REPORT6');
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_COMM_MODE,SYNCHRONOUS);
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_DESTYPE,cache);
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_DESFORMAT,'PDF');
    SET_REPORT_OBJECT_PROPERTY(repid,REPORT_OTHER, 'paramform=no');
    v_rep := RUN_REPORT_OBJECT(repid,plid);
    rep_status := REPORT_OBJECT_STATUS(v_rep);
    WHILE rep_status in ('RUNNING','OPENING_REPORT','ENQUEUED')
    LOOP
    rep_status := report_object_status(v_rep);
    END LOOP;
    /*Display report in the browser*/
    WEB.SHOW_DOCUMENT('http://Machine_Name:8889/reports/rwservlet/getjobid'||substr(v_rep,instr(v_rep,'_',-1)+1)||'?
    '||'server=repserver&P_parameter='||:block.item||
    '&paramform=no');
    END;

Maybe you are looking for