Code group in notification
Dear all,
i m using code group in pm notifications for malfunction codes.
Is there any standard report i can get equipment malfunctions according to malfunction codes?
I have checked iw28 , but seems not working.
Thanks
Hi
It gives the details of the code group and code, which u give in catalog...
You need to get the text which u have written in the PM Notification...under damage and under causes...
Once u get the code group and code itself... i hope its sufficient...
- Pithan
Similar Messages
-
Error in notification- Wrong Code group displaying
While creating Notification, we can assign codes for defect loc, def type and causes. After that, If I go in change mode of same notification, code group for defect type and causes are default taking as code group assigned for defect location.
Also the code group for defect type and causes are not even displaying in screen.
But the data for defect location is showing everything fine, means code group, codes.
Summary:
In QM02- Change Notification
Defect Location:
Code group- Correctly displaying whatever assigned during creation of notification
Defect Loc code: Correctly displaying
Def Loc description- Correctly displaying
Def Type:
Code group- Displaying same code group of def location
Defect type code: No display
Defect type description- No display
Causes:
Code group- Displaying same code group of def location
Causes code- No display
Causes description- No display
Did anyone faced the same issue before. If so plz ley me know
Thanks
VineethClosed, enhancement done in PM Notification caused this error. Internal error. Solved
-
Notification- code group defaulting
I customized a notification and every time I want to assign task code group and task code to that notification. Is it possible to assign/bring only required Task Folder to that notification, so I dont have to select task code one by one every time.
Purpose is to write long text comments against each task code in notification. Task codes will remain same for this notification.
Conculding:
Once I selcet particular Notification Type, Task Codes also should get selected and displayed automatically in Task field like default tasks.
Is it possible to do in this way?
Thanks in Advance
Vineeth Varghesehi
you can only resist the selection option , i dont know is there any possibility for defaulting all the task code
Also refer [here|http://help.sap.com/saphelp_47x200/helpdata/en/e1/8e51341a06084de10000009b38f83b/tree.htm] for automatic determination of task
regards
thyagarajan
Edited by: thyagarajan krishnamurthy on May 30, 2008 3:51 PM -
Deactivation of code groups and task codes in PM/CS notification
hi experts, would like to ask regarding Plant Maintenance and Customer Service module. Is it possible to disable code groups and task codes assign to notification type? instead of just deleting it? We have a config made on which the old format is no longer applicable so we need to exclude the old one on the selection so that users may not be confused of having so many options in the list.
Please suggest procedure on how can I make it.
Thank you so much.Hi Marnee,
How did you manage to disable code groups? I am looking to do the same thing.
Thanks,
Dean -
F4 help for Code groups while creating a notification.
Hi all,
We are using Exit QQMA0015 to filter the code groups for object parts, Damage, Causes and Activities based on the Z table.
Our requirement is based on Object Parts, we want to restrict f4 help for Damage and then based on Object Parts and Damage we want to restrict f4 help for Causes and so on for Activities based on the Z table . And we are going to maintain multiple values for one Object Part.
For e.g. If we have two entries for Damage code group in z table based on the Object Part, then both these code groups should be shown on f4 help of Damage. So we want to pass multiple code groups from the Z table
We are facing an issue like the export parameter E_codegruppe is an variable and hence we can pass only one value. So in the loop we are trying to pass both the values to the table T_RIWO020TAB and in the exit this table is getting filled with the values we want.
But once we are out of exit the standard table G_RIWO020TAB in the FUNCTION'CATALOGUE_SELECTION' is having values as per standard configuration and we are not able to get the values we want.
Please suggest on the above mentioned requirement. This will be really helpful for us.
Thanks & Regards,
Sonali Deshmukhdone
-
Can anybody please tell me,
Why & when it is necessary to maintain code group & selected sets. Where it is then use. What is releation between them.Will appreciate if explain with suitable example from industry. Please helpout.Newcomer in QM.HI
code groups are used in Notifications and quality result parameters.
Code groups are used to combine and structure codes within a catalog type
code groups at client level to group codes that have the same contents or relate to one another, within a catalog type. Codes, that are assigned to a code group are also known as group codes.
When you maintain the code group index, the system locks the required catalog type for other users. However, if you use the individual maintenance function, only the required code group is locked.
these are can ot create by plant wise.
1.when you have material which measures by means of color then you canhave code group color and codes of red ,black etc..
2.if you have defect codes then you can mention them
3.if you have problems of perticular part, then in notification by use of codegroups and codes you can enter the data.
A selected set contains a combination of different codes at plant level, for example, coded descriptions of characteristic attributes (such as color, shape, surface characteristics), defect causes or usage decisions from different code groups.
selected sets to combine codes from several code groups for processing that are allowed or useful for a particular application.
Codes that are copied into a selected set are known as set codes.
When you maintain the selected set index, the system locks the required catalog type for other users. However, if you use the individual maintenance function, only the required selected set is locked.
4.with combinationof code and code groups you can create the selected sets , canbe used in Usage decission.(ex:aprroved, no approved,ok, not ok etc)
Code groups are createsd by Qs41
Logistics ® Quality management ® Quality planning ® Basic data ® Catalog ® Code group ® Edit
Selected sets are created by QS51
Logistics ® Quality management ® Quality planning ® Basic data ® Catalog ® Selected set ® Edit
-ashok -
Code Groups not visibile in QS41
He experts,
I have created catalogs by t-code: QS41.
After the entering and saving the code groups and codes system is not showing the codes for the code groups.
Only code groups are visible. However I can see and use the code groups while donig transaction i.e. in notification in filling the history details.
Please tell me if there is any settings need to be done so that codes are visible in QS41.
I am working in ECC6.0
Regards
Pankaj VermaThis is a basis problem. install note number 1078292. Read the below summary , you will get the proper information.
Summary
Symptom
This note has been created to correct a bug introduced by the note 1067720. The symptom is related to the Selection Condition for Character fields, where preceding spaces are truncated, in View Maintenance.
Other terms
View Maintenance, Selection Condition, VIEW_FILL_WHERETAB, note 1067720, wrong output, QS41, QS42, QS51 QPAC, QPAM, QPCD, Catalogs, Codes
Reason and Prerequisites
The error is due to a wrong correction done in note 1067720.
Solution
Please apply the attached corrections.
Header Data
Release Status: Released for Customer
Released on: 25.02.2008 13:37:14
Priority: Correction with medium priority
Category: Program error
Primary Component: BC-CUS-TOL-TME View Maintenance Tool
Secondary Components: CS-CM-SN Service Notification
PM-WOC-MN Maintenance Notifications
QM-PT-BD-CAT Catalog
Affected Releases
Software
Component Release From
Release To
Release And
subsequent
SAP_BASIS 60 620 640
SAP_BASIS 70 700 700
SAP_BASIS 71 710 710
Correction delivered in Support Package
Support
Packages Release Package
Name
SAP_BASIS 620 SAPKB62065
SAP_BASIS 640 SAPKB64023
SAP_BASIS 700 SAPKB70014
SAP_BASIS 710 SAPKB71004
Corrections Instructions
Correction
Instruction Valid
from Valid
to Software
Component Type *) Last
Modifcation
578289 700 700 SAP_BASIS C 26.07.2007 11:43:00
578290 710 710 SAP_BASIS C 26.07.2007 11:55:27
943249 640 640 SAP_BASIS C 20.10.2007 12:59:47
943250 620 620 SAP_BASIS C 20.10.2007 13:01:23
*) C Korrektur, B Vorarbeit, A Nacharbeit, M noch nicht bestimmte Arbeit
Related Notes
1091604 - SM30: Error SV068 on Selection Conditions
1067720 - SM30: Improper selection of entries in the table/view
440521 - Overview: Notes for FS-RI
Print Selected Notes (PDF)
Causes - Side effects
Notes / Patches corrected with this note
Note
reason From
Version To
Version Note
solution Version Support
Package
1067720 1078292 1 -
Catalog -code group & codes (object part,causes,damage,etc)
Dear PM gurus,
request kindly help to activate and flow the catalog - code groups & codes in standard report of iw29 or iw59 for the following code group & code
Notification Header level of Items :
1. Code group - Object part & code
2. code group - Damage & code
Sub header level of Items -- CAUSES
1. Code group & Code
Cause code text & cause text
in pm & service notification we are using the above code groups & codes, but the contents are not flowing in IW29 & IW59, pl help
thanx in advance
regards
Sriharihi arun,
can u pl tell me whether i get
code group text & code text of the following in iw29 report thru filter?
causes
damage
activities
the above codes are given in pm notification, expecting the same info in iw29, pl do check thru set filter and let me know whether we get these along with (code group, coding code )
pl help if u know which report the above are coming
thanx in advance
regards
srihari -
Code groups, codes & selected sets during UD
Dear Friends,
Can I create my own catalog types.
I have created my own catalog types.
1) For Usage Decision (R)
2) For Defets recording (P)
During defect recording the system is picking the code groups & codes created by me and which are assigned . It is not showing other ones.
But during Usage decision it is picking all the code groups, codes & selected sets attached to standard UD catalog "3".
I am unable to understand how the system is behaving like this.
I have created my own notification type Y1. I have created my Catalog profile (YQM000001).
I have assigned this profile to inspection type.
I have assigned this notification type to inspection type.
In the catalog profile YQM000001, I have assigned two catalogs (R & P).
In catalogs & catalog profile for notification type, problems field assigned the catalog type "P".
One more issue while recording the defects I am getting notification type as Y1 (created by me) but the catalog profile is showing standard one "QM0000001".
I am unable to understand these all. Do anybody has got any solution.Dear Anuradha,
There is no need to create separate catalog type for your problem of displaying specific UD codes while giving user decision. You can assign the specific 'UD selected set' from catalog type 3 ( User decision) in SPRO ' Maintain inspection type' for QM. Following is the path you can assign the desired UD option you need to see while recording UD:
SPRO >> Quality Management >> Quality Inspection >> Inspection lot creation >> Maintain inspection types >>execute >> select the inspection type say '01' and view details >> there will be field UD selected set, assign the specific selected set made for your plant and save.
By doing this when you go for giving any UD, codes defined by you only will be displayed (not all).
Didn't understand your issue related to notification, but in same above screen you can also assign notification type for particular insp. type.
Looking at your requirement there is no need to create separate insp type or notification type just make proper use of existing one and do proper assignment.
Please let me know if you have any problem in resolving this.
Best Regards,
Shekhar -
Code under code group disappear after creation
Hi all,
I have two questions on following which are link to each other:
Q1 u2013 Code created inside a newly created code group is disappearing.
>> When I created a code group using QS41 with status of the code group indicated as u201CReleasedu201D. Next I went to create three codes with individual defect class under the code group screen. Lastly, I hits save.
>> Next, I went to QS42 (display) on this code group. However, surprisingly, all the codes created under this code group were disappeared. May I know why?
Q2 u2013 Using defect class to activate a defect record as quality notification automatically during defect recording.
>> I read this section in SAP help portal that I can activate a defect class in customization to automatically activate a quality notification (i.e. so that the defect class can automatically activate a defect record as quality notification during result recording so that the user can continue process the quality notification. How do I do this in system since I keep on getting problem on question 1 on above? Even after question 1 on above solved, what are the relevant steps that I require to configure in order to make this function working?
Thanks
YYHi Gajesh,
It is on Quality client.
May I know why the codes created in the group code are diappear after the code were create?
What about question 2.
Appreciate.
YY -
Dear all,
We use quality management module. My requirement is in notification of type Q3 we use code group to enter defects, is there any possibility of restricting certain codes of the code group for certain users only.
i.e., if i have a code group x of catalog type 9 wherein in x we will have various defect codes like d1,d2,d3....... - Can these codes for example user1 can only select codes d2 and user2 can select any codes from d1,d2,d3...
Regards,
M.MClosed
-
hi pm gurus,
we have customised catalog code for our pm-cs notificatcations.
we have code groups & codes under catalog.
we have created lot of code groups & codes in code groups, now we wanted to delete or deactivate or block some of the code groups & codes. how this is possible ?.
pl help.
regards
sriharihi,
Please note down the path for deactivation of catlogs.
SPRO --- Plant maintenance & customer services - --- Maintenance & service processing -
maintenance and service notification -
notification creation -
notification conents....Maitain Catalog..
click on define catalog....
What u r asking is only about... catalog that's is the combination of code groups.....
from here u can deactivate catalog...
incase of doubt please ask...
Regards,
Amit kushwaha -
Hide Code Group code as selection
When we develop Code Groups and Codes, after a period of time the Code is no longer to be used. I understand that it can not be deleted as it has usage, but why can't one flag similar to the Code Group itself so it will not be visible for selection. Right now we change description to DO NOT USE, but users still select code.
Hi,
It is possible to delete the catalog codes inside the group.
For that, first you have to define your own catlog type (as SAP recommends not to change the settings for the SAP defined catalog types).
Procedure:
- Define catalog type say 'Z'
- In config set the check box Deactivate. (Read F1 help on this checkbox)
- Now define the codes for this type in QS41.
- Use the code somewhere (e.g. Notification)
- If u check QS41 again, it will have usage indicator.
- But you can delete the entry ignoring the warning message.
Let me know if this fulfills the reqmnt.
regards -
SAP QM unable to pick Code group & code in creation of defect in QA32
Hi every one,
I am new to QM , can any one guide me to solve this issue.
In T code QA32 after results recording, am trying to maintain defect document of one of reject MIC. But, i am unable to pick Code group or code. System showing error "Code group QM-Q contradicts the code group of the catalog profile "
Regards
SrinivasHello Srinivas,
Check below path and let me know what settings you have maintained.
Now, Also check your Catalogs profile, You have to maintain Catalog "Z" for the same catalog profile.
Amol. -
Hi,
I would like to know the possibility of grouping the Notifications based on Operating Units.This is client requirement and want to get the list of Notifications based on OU.
Pl help me how to resolve,
regards,
venkatHi,
You'd have look at each of the Workflow item types required to be grouped on a case by case basis. Notification links back to item, which corresponds to an underlying entity (e.g. PO - which is associated with an organization unit).
Regards,
Gareth
Blog: http://garethroberts.blogspot.com/
Maybe you are looking for
-
About AP Down Payment Request, AP Down payment invoice and AP reserve inv.
Hi: Which are the main differences? I need to pay in advance to my supplier 100% of the invoice, the purchase invoice would be received one month later. How can i link them? And what about the payment, how can i remember easily that invoices are miss
-
How do you create a bootable image accessable via OPTION at boot time...
Hello. Is there a way to create a 'bootable image' of a hard drive and save on my raid and access it via the OPTION menu (hold option key at boot)? I would like to create a OSX bootable drive and then save the whole thing in a file. That way I can se
-
Hi, when materials are replicated we found a queue existing in SMQ1 and SMQ2. When i have checked in SMW01 for the Log it showed me the error "Allocation of the tax for country RO, sequence 1, value 0 not possible" Then i clicked on Show BDoc Message
-
Shared hard drive from USB on Airport?
Is it possible to use the usb port on an airport express to connect a usb hard drive so that it s then shared on a wireless network? Would this still work if the Airport Express is being used as an ethernet bridge (I'm not sure if I'm using the right
-
Hello, I am writing to know can you please help me. I am trying to writing a PID control programme for a water level control project I am doing but when I use labview and select a daq assisitant it does not show terminals onit therefore I cannot wire