Hi experts,
I can set different color for different systems (DEV, QUA , PROD) but my user can't.
After logging in a system, in option, the "color in system" is blank for my user for Enjoy Theme : he has this message "to change/set settings on this page, you need to start the SAP GUI Options dialog in Enjoy Design" .
Does anyone know how to activate the "color in system" in the options?
Thanks in advance,
P.

Hello Pete,
The following provides additional information on the color theme
settings:
710719 SAP GUI family and New Visual Designs
To set the default theme for all users of a system the parameter
"sapgui/theme" in transaction RZ10 as detailed in note 610274.
With this global theme set, this can be changed on the users side
individually as per user desire.
If you want to roll out themes as a script then you can use
the following registry entries;
Note that HKEY_CURRENT_USER will allow the end-user to make changes.
If you wish to make the changes permanent then also use
HKEY_LOCAL_MACHINE with the same registry entries and that
should work.
The following registry key:
HKEY_CURRENT_USER\Software\SAP\General\Appearance\Systems\
will list the systems that the user logs onto e.g. PRD1
Under this registry setting there are 2 keys:
ActiveColorSetting:
Theme:
which could be given the test value e.g
For system PRD1
HKEY_CURRENT_USER\Software\SAP\General\Appearance\Systems\PRD1
ActiveColorSetting: Rose
Theme: Enjoy
And for another system TST1:
HKEY_CURRENT_USER\Software\SAP\General\Appearance\Systems\TST1
ActiveColorSetting: Peach
Theme: Enjoy
Please note that the above are just an example so I would recommend
trying these out on several test machines on your side.
As the above are manual registry changes please note the following:
- If any undesired side effects occur then please remove the registry
  entries immediately.
- If the changes are going to be used then please try on a test client.
- Future patches may undo the registry changes and there is the
  possibility that the changes may not work correctly if future patches
  change the registry structure.
- Please note that while this change appears to function correctly &
  without side-effects in our test system, undesirable effects from this
  change will not be supported by SAP until the registry entries are
  removed
Hope this can assist you.
BR,
Jude

Similar Messages

  • ALE Change Pointers in source system not active

    Hi All,
    I am trying to load 0COSTELMNT using deltas. The initial load is OK and then i use a delta and it fails and i get the error:
    "ALE Change Pointers in source system not active"
    I have carried out the following steps in an attempt to resolve the problem - but it didnt. Anyone have any advice??
    (1) Checked BD61 – to confirm whether the change pointers are active
    (2) Checked BDCP to confirm the number range is maintained
    (3) Checked SALE (Activate change pointers for message types)  to confirm whether the change pointer has been activated for the type we need:
    COCOKA     Control segment CO object/cost element
    COELEM     Cost element master data
    (4) In transaction snum, Selected number ranges and confirmed the intervals are setup
    No. 01
    FROM: 0000000001
    TO: 0000009999
    (5) Activate transfer structure
    (6) Replicate Datasources
    Thanks,

    If you are transferring master data from source system, the BD61 setting on the source system should be checked.
    Why it has been unchecked - not sure (likely someone did it by mistake).
    It shouldn't have any effect on txnl delta. What will be effected though is that you will have lost delta of the ALE based data sources for the period this setting was unchecked.

  • Source system not Active error while installing BI content cube

    Hi.,
      When I try to install the BI content cube, In logs it is showing the error message as "Source client not Active". I activated the source system in modelling tab. Still the problem continues.  In source system assignment of BI content the source client is also checked. Please give me a solution.

    Hi Selva,
    If you want to select only infocube, select "Only necessary objects" in grouping. If you want everything related to Info cube, then system will collect data source also and for that it will check if you are authorized in source system. Please check if the source system is connected to BI or you can do one thing activate the data source in source system and replicate it in BI.
    Regards,
    Kams

  • Executive Information system not activated in COPA

    Hi gurus
    Gone live in feb 08.
    Not activated information system in COPA.
    If they activate now in AUG 08. whether standard SAP CO Reports will pick up data from FEB 08 .
    Thanks and Regards

    Hi,
    For me, it looks that you have gone live with COPA sans COPA Reports. If it is so, all data might have gone to COPA from Feb 08 onwards. Check the records in the table CE1XXXX where XXXX stands for your operating concern thru SE11/SE16.
    Hope this helps,
    Cheers

  • Source System of Dev System is not active QAS System.

    Hi
    I am trying to transport my SAP-BI flow from Dev System to the Quality System.
    but I am getting an error  "Source System of Dev system is not active in QualIty System.
    I have checked RFC Connection ,everything is fine.Please help.
    Thanks and Regards,
    Asim

    Have you checked the mapping of the source systems in the conversion table (RSLOGSYSMAP)?
    Usually, DEV source systems are not available in QA, so when you transport to DEV, the source system assignment has to be changed to a QA source system.
    For example, source system CRDCLNT100 (CRM DEV system) is connected to BWDCLNT100 (BW Dev)
    and CRTCLNT100 is connect to BWTCLNT100.
    Objects in BWD which are assigned to CRD, have to be re-assigned to the CRT source system when transporting them from BWD to BWT.
    The mapping table is maintained in RSA1, menu option tools > 'mapping of the source system names'.
    Jan.

  • Infoobject 0CEPRCS5 not active in the system

    hello all,
    When I am trying to install anything from BI Content. I am getting these pop ups:
    Infoobject 0CEPRCS5 not active in the system and is being deleted"
    And it keeps on going for alot of infoobjects, a few of them being 0CEBQRQM,0CERVSVOL,0CECLSM ...all are starting with 0CE.
    I need to hit ok to get through all these pop ups and then my objects continue collecting.
    What is this pop up for, is any one else seeing these pop ups?
    Thanks,
    Kiran

    For the sake of discussion, I have the same issue for e.g. 0VKAPPSID and 0VKDLGID, when collecting the <i>not assigned characteristics</i> IOCatalog and the related objects before the data flow.
    Davide

  • ARD 3 'not active' despite System Preferences saying it is!

    The setup - a network of 54 Macs of various configurations on a Windows 2003 network running 10.3.9 have ARD 3 installed. All is well.
    The change - due to a Microsoft patch on our network, we were forced to upgrade to Tiger. We purchased 10.4.6 on DVD from CDW and installed. But 10.4.6 is problematic with Adobe CS - so we were forced to downgrade to 10.4.5
    The problem - after this downgrade to 10.4.5, we made sure ARD was still turned on in the System Preferences. But when I look with the application, every single one says the ARD is not activated!
    What do I have to do to get them back?

    No, all the of the users were active.
    Despite the OS reinstall putting ARD 2.2 back into the system, ARD wasn't active. So I went back into the Previous system and found the ARDAgent that was removed by the reinstall. I copied the RemoteManagement folder from the System/Library/CoreServices folder and replaced the new RemoteManagement folder that had been recreated.
    Voila - ARD is working perfectly again.
    So because I had ARD 3 installed, when we did the OS reinstall it put in ARD 2.2 which my ARD software couldn't recognize anymore. It didn't even recognize that it was 2.2 - just said ARD not active. I replaced the 2.2 ARDAgent with the 3 ARDAgent from the Previous system folder and all is well.

  • My apple is not activating,Asking for Apple ID &p.word, I have entered the apple ID which i was using to download all apps,but it wont work, Now system is saying that your apple Id is wrong, My question is Can there be two apple IDs?

    My apple is not activating,Asking for Apple ID &p.word, I have entered the apple ID which i was using to download all apps,but it wont work, Now system is saying that your apple Id is wrong, My question is Can there be two apple IDs? My apple ID is my Yahoo mail it self, but not able to log in to  Icloud, Can any body guide, Why, I can not.

    Hi dip_kinu,
    I apologize, I'm a bit unclear on exactly what device you are trying to set up and what is happening when you try to do so. If you are having issues remembering your Apple ID, or feel like you may have set up multiple Apple ID's, you may find the following page helpful:
    Apple - My Apple ID: Find your Apple ID
    https://iforgot.apple.com/appleid
    Regards,
    - Brenden

  • I am trying to sync my itunes with my ipod, but when I get to step 3 of syncing, it stops. Also, I deleted all the songs on my ipod, and when I go to my music in my ipod the songs are all still there and in a grey color and I'm not able to select them.

    I am trying to sync my itunes with my ipod, but when I get to step 3 of syncing, it stops. Also, I deleted all the songs on my ipod, and when I go to my music in my ipod the songs are all still there and in a grey color and I'm not able to select them. How do I completely clear my ipod music, and how can I solve the syncing problem?

    Sync works the same way it always has, connect the device, select the content desired to sync and sync.
    All the media should be in iTunes already, iDevices are not and have never been backup devices.
    If this is a new computer, move the content from the old computer to the new computer.

  • Receiving error message 'Could not load file or assembly 'System.ServiceModel.Activation, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified.'

    I started getting this error message for the first time today. When I look in the event log I see it every time anyone tries to sync to a mobile device to the exchange server. I've also had this problem trying to connect using
    Outlook. I believe it is an IIS issue but I'm not absolutely sure so I'm posting this in the Exchange forum as well.
    The event viewer has the following information...
    3008
    A configuration error has occurred.
    5/1/2014 10:41:08 PM
    5/2/2014 5:41:08 AM
    7539d8a38c8b47869eda3f1749aba08d
    1
    1
    0
    /LM/W3SVC/1/ROOT/Microsoft-Server-ActiveSync-75-130434828686436855
    Full
    /Microsoft-Server-ActiveSync
    C:\Program Files\Microsoft\Exchange Server\V14\ClientAccess\sync\
    SERVER
    16284
    w3wp.exe
    NT AUTHORITY\SYSTEM
    ConfigurationErrorsException
    Could not load file or assembly 'System.ServiceModel.Activation, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified.
    https://remote.testserver.com:443/Microsoft-Server-ActiveSync/default.eas?User=user.name&DeviceId=ApplC39GQ5xxxxxx&DeviceType=iPhone&Cmd=Ping
    /Microsoft-Server-ActiveSync/default.eas
    174.224.130.31
    False
    NT AUTHORITY\SYSTEM
    24
    NT AUTHORITY\SYSTEM
    False
    at System.Web.Configuration.ConfigUtil.GetType(String typeName, String propertyName, ConfigurationElement configElement, XmlNode node, Boolean checkAptcaBit, Boolean ignoreCase) at System.Web.Configuration.Common.ModulesEntry..ctor(String name, String typeName, String propertyName, ConfigurationElement configElement) at System.Web.HttpApplication.BuildIntegratedModuleCollection(List`1 moduleList) at System.Web.HttpApplication.GetModuleCollection(IntPtr appContext) at System.Web.HttpApplication.RegisterEventSubscriptionsWithIIS(IntPtr appContext, HttpContext context, MethodInfo[] handlers) at System.Web.HttpApplication.InitSpecial(HttpApplicationState state, MethodInfo[] handlers, IntPtr appContext, HttpContext context) at System.Web.HttpApplicationFactory.GetSpecialApplicationInstance(IntPtr appContext, HttpContext context) at System.Web.Hosting.PipelineRuntime.InitializeApplication(IntPtr appContext)
    I have tried most, if not all, of the different post's suggestions to no avail.
    The steps I have taken are as follows...
    1. Repaired .Net 4 (Both the client and extended)
    2. Uninstalled and reinstalled .Net Framework 4.0.
    3. Verified that the dll exists.
    4. Checked the applicationHost.config file. It contains the follow statement...
    <add name="ServiceModel-4.0" type="System.ServiceModel.Activation.ServiceHttpModule, System.ServiceModel.Activation, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35" preCondition="managedHandler,runtimeVersionv2.0"
    />
    5. Changed the following line in web.config to include the runtimeVersion...
    <add name="ServiceModel" type="System.ServiceModel.Activation.HttpModule, System.ServiceModel.Activation, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35" preCondition="managedHandler,runtimeVersionv2.0" />
    6. Executed aspnet_regiis.exe -iru from the ...\Framework64\v4.0.30319 directory.
    7. Went to inetpub\history to use an applicationHost.config file from yesterday but it only has history from 9PM tonight. It probably had what I needed before I started changing it tonight.
    I still receive the same error message.
    Like I said everything was working yesterday. In fact I didn't hear or see any issue until after 1PM today.
    Any help would be very appreciated!

    Hi,
    Please confirm whether users can access their mailboxes from Outlook Web Access or not. We can do the following changes to have a try:
    1. In IIS > Application Pools, change the .NET Framework Version to v2.0 and restart IIS service.
    2. If it doesn’t work, explore the Default Web site.
    3. Renamed the web.config file to web.config.old
    4. Reset IIS using iisreset command to have a try.
    Thanks,
    Winnie Liang
    TechNet Community Support

  • To Apple Inc. respectable brothers, dear, I've purchased a Yvonne immediately after S Black color I did not know that the owner of the device may do Service i Claude and I've work restor of Yvonne and when activation asked me to calculate i Claude and I d

    To Apple Inc. respectable brothers, dear, I've purchased a Yvonne immediately 4 S Black color I did not know that the owner of the device may do Service icloud and I've work restor of Yvonne and when activation asked me to calculate icloud and I do not know;  I do not know who is the owner of the device with science I bought the machine from Turkey Fargo to help me, I was involved with this device, and I'm from users of the iPhone please help me thank you with the knowledge that Amy device is 013186007698501
    If it is possible to activate the iPhone and that did not help me Fargo just inform me or give me the e-mail which has enabled Claude feature so that I could e-mail correspondence on Arslo Please e-mail me
    For I am God and you will lose device safely God

    Birden konuları gönderme Lütfen dur.
    Buraya git -> https://discussions.apple.com/message/24870284 # 24870284

  • HT4293 i am trying to use dual monitors when editing with FCPX. I have a macbook pro and an apple cinema display monitor. I have connected them and opened Fcpx but the option to use second monitor is not active! what do i do ? please help going bonkers!

    i am trying to use dual monitors when editing with FCPX. I have a macbook pro and an apple cinema display monitor. I have connected them and opened Fcpx but the option to use second monitor is not active! what do i do ? please help going bonkers!

    <http://support.apple.com/kb/HT5891>
    You can use USB for the Apple trackpad.
    <http://www.mobeetechnology.com/the-power-bar.html>

  • CreativeCloud.exe doesn't work anymore. It seens to be not activated in the system tray.

    Hello and sorry for my english. My name is Jean-Pierre BRETHES and I have a problem with the creativecloud.exe program which doesn't want anymore to start. (since a while now) The icon in the system tray doesn't appear and it still to be gray (not red). When I clic to lunch the program nothing happen. When I try to reinstall it the download end by a windows "error 50" and everything is stopped.
    AT the beginning I wanted to download In design  program to try the PAO functionalities. Thank to help me. My email adress is <removed email - kglad>. Have a nice day. JP

    Hello and sorry for the delay. Thank you for your answer. I did what you wrote and everything is fine now. Really thank you for that. I fully understood regarding my email address in my message. I will not anymore do this error.
    Have a nice day.
    Sincerely, Jean-Pierre BRETHES
    De : kglad 
    Envoyé : dimanche 6 juillet 2014 23:33
    À : Jean Pierre BRETHES
    Objet :  CreativeCloud.exe doesn't work anymore. It seens to be not activated in the system tray.
    CreativeCloud.exe doesn't work anymore. It seens to be not activated in the system tray.
    created by kglad <https://forums.adobe.com/people/kglad>  in Downloading, Installing, Setting Up - View the full discussion <https://forums.adobe.com/message/6527054#6527054>

  • Source system is not active?

    Hi,
    I have Data source created in CRM and I have created a Info source and Source system is connected with the data source I am getting a message "Source is not active".
    Can any please help me to understand about this?
    Points will be definitely assigned.

    Hi Vasu,
    In RSA1 check for your CRM source system and do a check on the source system whether it connected with BW system or not.
    RSA1-->Source Systems and right click on CRM Source System name and check. This check shoul be active, if not contact concerned person.
    Regards,
    Saravanan

  • For 0PS_C02  cube  Project System - Dates update rules not activated!!

    Hi All,
    When we are trying to install update rules from the BI content for PS module  for the cube "0PS_C02  Project System - Dates",  the
    update rules are not activating. under the cube when BI content activation. What is the issue in activating the update rules from BI content. From BI content the available version objects only will be activated i think. Please rectify and resolve the same at the earliest friends.
    thanks,
    Sakali

    Hi,
    Try to activate through program RSAU_UPDR_REACTIVATE_ALL.

Maybe you are looking for