Communicat​ion error with GPIB

Hello,
i am using GPIB card but its not communicating.
The Error is : Error connecting to Driver or Device.
I have tried it all possible ways, and one thing is that its not shown
in the Measurement Automation Explorer software.
Any one has solution regarding that pls send me an email
[email protected]
i am desperately waiting.
thnx
Bye.
Safdar...

Is this an NI card? What model? Does MAX show that NI-GPIB is installed (assuming you have an NI card)?

Similar Messages

  • HP Photosmart C4380 [8A36CB] communicat​ion error with MacBook OS 10.7.5 over wireless

    Hi,
    I keep getting the message 'communication error' when trying to print wireless to a Photosmart C4380 from my MacBook (OS 10.7.5) through a TimeCapsule 2Gb router.
    The message also says: "/usr/libexec/cups/backend/dnssd failed" but I don't know what to do with it...
    I tried to de- and re-install, restart laptop, printer and router and pull all plugs in different sequences, first use the USB cable to install wireless and all other help from HP ... but nothing seems to work (HP Doctor is not available for Mac).
    The strange part is that:
    1.it started a couple of weeks ago, without having changed anything (by my knowledge),
    2. printing from my iMac works fine (same wireless network, same software version, same settings, etcetera)!!!
    2. printing over USB from my MacBook works fine
    3. I can print a test-page from "HP Utility" form my MacBook (and of course from my iMac but that one works fine anyway)
    4. I can access the printer through "http://hp8a36cb.local./index.htm?cat=info&page=pri​nterInfo" and there are no issues mentioned whatsoever,
    5. the 'HP Network Configuration Page' and the 'Wireless Network Test Report' congratulate me on the successful setup of my wireless printer... but it doesn't work.
    I've read almost all posts about communication errors over wireless but haven't found an answer to my issue (yet).
    Is there anyone with a solution? Please??
    This question was solved.
    View Solution.

    Download and install this: http://support.apple.com/kb/DL907
    Restart your Mac.
    Reset the printing system:
    - Go to System Preferences > Print & Scan
    - Right (or control) click in the rectangle listing your printers and select Reset Printing System.
    WARNING - this will delete ALL of your printers!
    - Select the plus sign to re-add a printer. Select the Defualt tab on the top of the window. Look for the printer, select it and then next to the "Use" pulldown, select the printer model (not AirPrint). Wait until the "Add" button becomes available. Click it.
    Say thanks by clicking "Kudos" "thumbs up" in the post that helped you.
    I am employed by HP

  • COMMUNICAT​ION PROBLEM WITH BATTERY

    AM USING THINKPAD E531, RECENTLY LENOVO SOLUTION CENTRE SHOWS A ERROR MESSAGE THAT MY LAPTOP HAS COMMUNICATION PROBLEM WITH MAIN BATTERY AND ALSO IT SHOWS HEALTH MONITOR HAS NOT AVAILABLE.
    PLEASE RECOGNISE MY PROBLEM, SOLVE IT

    There might be a problem with your code. Here is an example program. Try running this, if this does not work and you are still seeing the same results as before, repost.
    This is a simple MSVC program to demo how to communicate with GPIB instrument with VISA commands with language interface Microsoft Visual C++.
    This program includes viOpenDefaultRM(), viOpen(), viSetAttribute(), viWrite(), viRead() and viClose(). To Run VISA commands in MSVC, "visa.h"
    and "visa32.lib" need to be included in the project. For detail information of the program, please see the comments inside the file VisaGPIBforVCDlg.cpp.
    Hope this Helps.
    JenK
    Attachments:
    VisaVC.zip ‏2285 KB

  • AI configurat​ion error with LockinDEMO

    Whenever I push the start button on the DEMO I get an error with my AI Group Configuration.

    Hello,
    Are you attempting to simulate a signal to see how the toolkit works or are you trying to use it with a piece of hardware that you have?
    If you are simulating, make sure that "SW" is selected beside "Signal Generator" instead of "Off" before you push the Start button.
    If you are using hardware you have then make sure you are referencing that piece of hardware on the front panel. Scroll the front panel over to the left and address your piece of hardware.
    Let me know if that doesn't solve the problem!
    Brian Spears

  • Problem with TCP/IP communicat​ion: error ni-448 when I want to write on a TCP/IP-con​nection

    Hi folks
    I have a really annoying problem: I want a computer (Win XP, Ethernet board, Labview 7.1) to communicate with my robot controller (Win 2k, Epson SPEL+ language). The robot controller is the client, the LabViewPC the server. now reading messages sent by the robot controller are no problem to read. But when I want to send messages from the LabViewPC to the robot controller I get an error message: error ni-448, make sure that the GBIP-controller is the primary controller.
    For the communication I open a TCP-listener and a TCP wait listener in a while loop. So far this works. Then I use the TCP-write function to send a string to the robot controller. Here the error described above occurs. So the communication doesn´t work.
    Can anybody help me?
    Please. Thank you in advance!

    hi there,
    are there several network adapters on your host? if so pass the IP of the network adapter to the "TCP listen.vi". i'm not sure but i think i remember that in former versions this had no effect. then you could use "TCP Listen.vi" on your slave and "TCP Open Connection" function on your host.
    you can use the "Simple Data Server" and "Simple Data Client" examples for a quick test.
    Best regards
    chris
    CL(A)Dly bending G-Force with LabVIEW
    famous last words: "oh my god, it is full of stars!"

  • 6500a e710 a-f - Scanner Communicat​ion Error Windows 8.1

    We have been experiencing issues with scanning whilst connected via USB, using the HP Scan software. The software returns an error message saying scanner communication cannot be established, half way through scanning. Then HPScan.exe fails to load again. The printer just says “scanning cancelled” on its display.
    This is only effecting one model of PC and that is a HP 8300 Ultra-Slim PC.
    We are running Windows 8.1 64 bit from an image install. However, I have tested this with a fresh Windows 8.1 retail installation and get the same problem.
    We have tried various actions to fix this:
     - Various accounts, admin accounts, domain admin accounts, local accounts etc.
     - Uninstall and reinstall. Basic and Full driver packages including the latest versions
     - Removed all other HP software from PC including registry keys
    - Used built in Windows 8 scan software with basic driver
     - All USB ports tested including 2.0, 3.0 and powered / non-powered
     - Replaced cables
     - Re-isntalled USB bus drivers for 8300
     - Followed the print/scan doctor which shows a driver error - scandriver unable to communicate with product
     - Run HPScan in compatibility mode for 7/XP
     - Updated firmware on printer
     - Installed latest Windows Updates
     - Checked WIA service and dependencies are running
     - Semi and Full factory resets on Printer
     - Shell hardware detection service set to manual
     - We have replaced the printer for an affected user - same issue
     - Also replaced PC for an affected user - same issue.
     - Updated PC BIOS
    I have tested connecting the printer to the router with a network cable and then installing printer as a networked device rather than USB and then the hpscan.exe works. So this is only an issue with USB (though it wouldnt be practical to try and talk 200+ users through networking their printer).
    As you can see, we have tried almost everything. Interestingly we havent been able to replicate this issue in one of our main offices - despite collecting the same PC and Printer from an estate and bringing it back to an office.
    We have also sent out a working PC and Printer combo to an affected estate office and it has not worked there.
    Our Estate Offices connected via an ADSL Router and "My Documents" are re-directed to a network location. Could a failure in accessing this network location cause the problems? I have tested connectivity to network store from PC and it accesses the files fine.
    Any solutions would be greatly received, I have spoken to HP After Sales support but not received an working solution yet.

    Greetings, @Scammell29
    I have read through your post and have very ideas left for you, as you've tried quite the load of troubleshooting!
    I am thinking the issue could be power related, so try a power reset and plug the printer in directly to the wall outlet. Avoid power bars, surge protectors, etc. Just a direct plug in to the wall to test the power. Afterwards, see if you still receive the communication error.
    If the issue continues, next try a disk cleanup, the instructions are included in this guide: A 'No Computer Detected' or 'Connection Error' Message Displays during Scanning for HP Officejet 650...
    If the error still persists, perform a Clean Boot and restart the PC and then disable the Firewall and Anti-Virus scanners.
    Please let me know the results!
    Good luck
    R a i n b o w 7000I work on behalf of HP
    Click the “Kudos Thumbs Up" at the bottom of this post to say
    “Thanks” for helping!
    Click “Accept as Solution” if you feel my post solved your issue, it will help others find the solution!

  • How to resolve the serial communicat​ion error in HP34970?

    I want to use serial port to commnucation between pc and hb34970. In gpib mode, it is ok. But in serial mode, report error. just like this:
    for setting com2: 
    16:11:47.359 2009-8-26 [Init_dq_Device]error:-1073807339--HP34970A Initialize.vi->Init_DQ_Device.vi->main_app.vi VISA read.visa name:ASRL2::INSTR
    for setting com1:
    16:13:25.921 2009-8-26 [Init_dq_Device]error:-1073807339--HP34970A Initialize.vi->Init_DQ_Device.vi->main_app.vi VISA read.visa name:ASRL1::INSTR
    I don't know the meaning of -1073807339 and whether i should set:ASRL1::INSTR for com1. Anyone can help me about this problem.
    Thanks very much.
    attach my subvi.
    Solved!
    Go to Solution.
    Attachments:
    Init_DQ_Device.vi ‏48 KB

    Hi, Dennis Knutson
    very glad to see you.
    For my vi, i only provide a UI for user to select GPIB or serial mode, and setting related port.
    About "Also, the 34970 llb you are using should be replaced with the 8.x project library.", What do you
    mean? There is a new driver for 34970,right?
    I search the forum and find a old thread:Agilent 34970 Visa Timeout.
    There is your answer:
    I made a mistake. The initialize function already had a timeout function. I just didn't look at the VI closely enough. There is a case statement that sets either the serial port parameters or just sets the VISA timeout. If you are setting the timout right after the VISA Open, it's just getting set back to 10 seconds. Change it in the case statement and see if that works. Sorry, and I hope this works.
    Do you think this is the same with my problem? Your mean to modify default 10 seconds to more longer timeout,right? 
    Thanks.

  • Serial Communicat​ion Error -107380725​3

    Hello!
    I'm trying to make a simple serial port reader VI and i can't get over this:
    Error -1073807253 occurred at VISA Read in communication.vi
    Possible reason(s):
    VISA: (Hex 0xBFFF006B) A framing error occurred during transfer.
    I'm pretty shure that the device sending a data works properly and the parameteres like a boud rate, parity etc. are set correctly because I've already communicate with that device via Matlab.
    Although I've noticed that somebody here have the problem with this error, but I can't find any solution for me.
    There is a picture of my simple VI diagram in Attachments. The parameters of the communication are set at the beginnig, after that and a litle delay the input buffer is flushed, then the loop starts. When the buffer contain nine or more bytes this bytes are readen. 
    Please, can anybody tell me what I'm doing wrong?
    Thanks
    Attachments:
    VI-rs232-trouble.jpg ‏106 KB

    chikvadrat wrote:
    The VI works well after launch. It also read first 9 character correctly, but after that it crashs.
    So what happens if by the time the loops comes back around, you have 10 bytes waiting for you at the port?
    Bill
    (Mid-Level minion.)
    My support system ensures that I don't look totally incompetent.
    Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

  • THere was an error updating your sofware. An error has ocurred while updating your devices software. Device communicat​ions error encountere​d. [A:0x00000​00F].

    I've tried the suggestion "Please try the following: Disconnect your device and restart your computer. Restart the loading process"  multiple times with or without battery, but still the same.
    This error propmpted while loading the system software.
    Anyone encounter this issue befire and how to fix it, really appreciated
    Thanks.

    I found it in loader.log
    [3] [8est:58:28:921] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Writing to Loader Action Log "52BE2234:3.10.0.47TM connection type: PC"
    [3] [8est:58:28:923] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Got LAL_RESPONSE
    [3] [8est:58:28:927] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Retrieving persistent data struct
    [3] [8est:58:28:928] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Got persistent data struct
    [3] [8est:58:28:928] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Retrieving Blocked OS CFP
    [3] [8est:58:28:929] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Got Blocked OS CFP
    [3] [8est:58:28:929] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Getting the Device PIN
    [3] [8est:58:28:929] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Got Device PIN
    [3] [8est:58:28:929] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Getting the Device BSN
    [3] [8est:58:28:930] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Got Device BSN
    [3] [8est:58:28:931] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Corrupting opposite QNX partition 1, on archive load
    [3] [8est:58:28:980] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Programming Flash. Filesize: 1834156032 total bytes
    [3] [8est:58:39:751] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:1143] Command failed due to timeout
    [1] [8est:58:39:753] [CfpProgrammer] [0x00002f9c] [CfpProgrammer.cpp:859] cfp operation failed (15): "Device communications error encountered. [A:0x0000000F]
    Please try the following:
    - Disconnect your device and restart your computer.
    - Restart the loading process."
    [1] [8est:58:39:753] [QnxProgrammerHelper] [0x00002f9c] [QnxProgrammerHelper.cpp:288] CFP::LoadQCFMFile failed. Error: F
    [1] [8est:58:39:754] [QnxProgrammerHelper] [0x00002f9c] [QnxProgrammerHelper.cpp:322] WriteModule OS failed.
    [20] [8est:58:39:757] [Loader] [0x00002f9c] [Loader.cpp:877] Switching connect state from 3 to 0 (timeout 15000 ms)
    [20] [8est:58:39:757] [USBEnumManager] [0x00002a20] [USBEnumSerializer.h:66] Lock requested, maximum wait = 180000 ms
    [20] [8est:58:39:757] [USBEnumManager] [0x00002a20] [USBEnumSerializer.h:70] Lock acquired
    [3] [8est:58:39:757] [CfpProgrammer] [0x00002a20] [CfpProgrammer.cpp:1143] Requesting BootImage Exit

  • SPI communicat​ion protocol with LabVIEW and 6062E PCMCIA Card. Is it possible?

    Hey people. I'd like to know if it's possible to get SPI communication with 6062E card, and if there is any example of that use.
    Thank you!

    Good afternoon,
    With this hardware NI DAQCard-6062E (for PCMCIA) has inputs / outputs digital and analog, but has hardware that makes USB-8451 communication with SPI. Below is the link to the Hardware. Any questions please contact us.
    NI USB-8451
    http://sine.ni.com/nips/cds/view/p/lang/en/nid/202​368
    graciously
    Mauro Vera
    Applications Engineer
    National Instruments

  • Scheduled Delivery communicat​ion error

    See the post at this link: If your Scheduled Delivery apps stopped printing
    I work on behalf of HP.

    Hi  gailina,
    To assist you further on the issue please give me the details of the printer and when do you get the error code.
    Regards
    Aneesh
    Although I am an HP employee, I am speaking for myself and not for HP.
    --Say "Thanks" by clicking the Kudos Star in the post that helped you.
    --Please mark the post that solves your problem as "Accepted Solution"

  • Communicat​ion error code 243

    Can't receive fax messages due to error code 243

    Hi  gailina,
    To assist you further on the issue please give me the details of the printer and when do you get the error code.
    Regards
    Aneesh
    Although I am an HP employee, I am speaking for myself and not for HP.
    --Say "Thanks" by clicking the Kudos Star in the post that helped you.
    --Please mark the post that solves your problem as "Accepted Solution"

  • MAX communicat​ion hangs after Standby Mode(with GPIB PCMCIA)

    I have a IBM Laptop with MAX 2.2 and a GPIB PCMCIA Card installed. After booting the computer I can communicate with GPIB instruments without problems. After I get the Laptop out of a Standby Mode, MAX can not make any connection to GPIB devices; when I scan for Instruments it hangs as well.
    The troubleshooting wizard tells me: one or more GPIB interfaces failed.
    Does anyone have the same problems or solutions ?

    On the NI-488.2 2.0 download page it is mentioned that that driver does not support standby mode. No such mention is made on the download page for NI-488.2 version 1.7 (which I need to use for my PCMCIA-GPIB interface), although the 1.7 release shows very much the same problem: After stand-by, communication with the GPIB port is no longer possible.
    The Visual Basic example tool for preventing stand-by may help those users who are familiar with VB, but it does not help me.
    Frankly - what I'd like to see is an improved NI-488.2 version that does support stand-by. Does NI consider providing such an upgrade/patch?

  • Error With Export/Print from Crystal Report Viewer

    Hello there,
    I've searched through the web and SAP discussion boards with not much luck with this issue.
    After working through this for some days now I've decided to look here for help.
    Environment:
    I have created a web Crystal Report viewer application(Developed with SBOP BI Platform 4.0 SP06 .NET SDK Runtime) that communicates with a managed Cyrstal Server 2011 SP4 (Product 14.0)
    I am able to connect and authenticate with the server, retrieve a token for communication and display reports in the Crystal report Viewer successfully.
    Problem:
    When I attempt to export, I receive the prompt to select format and pages.
    When I click export after selections most times I receive an error with the text
    Unable to cast COM object of type 'System.__ComObject' to interface type 'CrystalDecisions.ReportAppServer.DataDefModel.PropertyBag'. This operation failed because the QueryInterface call on the COM component for the interface with IID '{74EEBC42-6C5D-11D3-9172-00902741EE7C}' failed due to the following error: No such interface supported (Exception from HRESULT: 0x80004002 (E_NOINTERFACE)).
    Other times the page simply refreshes on export.
    When I click to print, no print dialog is displayed the page always refreshes and no error is displayed.
    No Print or Export document is ever created.
    As many print/export issues seems to be related, I'm guessing this two issues are as well.
    Notes:
    I am utilizing the ReportClientDocument model
    I am storing this in session to use as the crystal report viewer report source on postbacks
    I am assigning a subset of export formats to the crystal report viewer
    I am setting particular parameters as well on the report source
    At this point I would appreciate every assistance I may receive on this issue
    Thanks in advance,
    Below is the pertinent code
    Code:
    <aspx>
       <CR:CrystalReportViewer ID="CrystalReportViewer1" runat="server"
       AutoDataBind="true" EnableDatabaseLogonPrompt="False"
       BestFitPage="False" ReuseParameterValuesOnRefresh="True"
      CssClass="reportFrame" Height="1000px" Width="1100px" EnableDrillDown="False"
      ToolPanelView="None" PrintMode="Pdf"/>
    <Codebehind>
    using System;
    using System.Collections.Generic;
    using System.Linq;
    using System.Web;
    using System.Web.UI;
    using System.Web.UI.WebControls;
    using CrystalDecisions.Enterprise;
    using CrystalDecisions.ReportAppServer.ClientDoc;
    using CrystalDecisions.ReportAppServer.CommonObjectModel;
    using CrystalDecisions.ReportAppServer.Controllers;
    using CrystalDecisions.ReportAppServer.DataDefModel;
    using CrystalDecisions.ReportAppServer.ReportDefModel;
    using CrystalDecisions.Shared;
    namespace ClassicInternalReportPage
        public partial class Reports : System.Web.UI.Page
            protected override void OnInit(EventArgs e)
                base.OnInit(e);
                if (!String.IsNullOrEmpty(Convert.ToString(Session["LogonToken"])) && !IsPostBack)
                    SessionMgr sessionMgr = new SessionMgr();
                    EnterpriseSession enterpriseSession = sessionMgr.LogonWithToken(Session["LogonToken"].ToString());
                    EnterpriseService reportService = enterpriseSession.GetService("RASReportFactory");
                    InfoStore infoStore = new InfoStore(enterpriseSession.GetService("InfoStore"));
                    if (reportService != null)
                        string queryString = String.Format("Select SI_ID, SI_NAME, SI_PARENTID From CI_INFOOBJECTS "
                           + "Where SI_PROGID='CrystalEnterprise.Report' "
                           + "And SI_ID = {0} "
                           + "And SI_INSTANCE = 0", Request.QueryString["rId"]);
                        InfoObjects infoObjects = infoStore.Query(queryString);
                        ReportAppFactory reportFactory = (ReportAppFactory)reportService.Interface;
                        if (infoObjects != null && infoObjects.Count > 0)
                            ISCDReportClientDocument reportSource = reportFactory.OpenDocument(infoObjects[1].ID, 0);
                            Session["ReportClDocument"] = AssignReportParameters(reportSource) ? reportSource : null;
                            CrystalReportViewer1.ReportSource = Session["ReportClDocument"];
                            CrystalReportViewer1.DataBind();
                //Viewer options
                // Don't enable prompting for Live and Custom
                CrystalReportViewer1.EnableParameterPrompt = !(Request.QueryString["t"] == "1" || Request.QueryString["t"] == "4");
                CrystalReportViewer1.HasToggleParameterPanelButton = CrystalReportViewer1.EnableParameterPrompt;
                CrystalReportViewer1.AllowedExportFormats = (int)(ViewerExportFormats.PdfFormat | ViewerExportFormats.ExcelFormat | ViewerExportFormats.XLSXFormat | ViewerExportFormats.CsvFormat);
            protected void Page_Load(object sender, EventArgs e)
                if (IsPostBack && CrystalReportViewer1.ReportSource == null)
                    CrystalReportViewer1.ReportSource = Session["ReportClDocument"];
                    CrystalReportViewer1.DataBind();
            private bool AssignReportParameters(ISCDReportClientDocument reportSource)
                bool success = true;
                if (Request.QueryString["t"] == "1" || Request.QueryString["t"] == "2" || Request.QueryString["t"] == "4" )
                    reportSource.DataDefController.ParameterFieldController.SetCurrentValue("", "STORE", Session["storeParam"]);
                    if (Request.QueryString["t"] == "2")
                        reportSource.DataDefController.ParameterFieldController.SetCurrentValue("", "FromDate", Request.QueryString["fromdate"]);
                        reportSource.DataDefController.ParameterFieldController.SetCurrentValue("", "ToDate", Request.QueryString["todate"]);
                else if (Request.QueryString["t"] == "3")
                    reportSource.DataDefController.ParameterFieldController.SetCurrentValue("", "SKU", Request.QueryString["sku"]);
                else
                    //Unknown report type alert
                    success = false;
                return success;

    Thanks Don for your response,
    I'm new to the SCN spaces and my content has been moved a couple of times already.
    In response to your questions
    The runtime is installed on the web application server, if by that you mean the machine hosting the created .NET SDK application.
    My question was whether it was also required on the Crystal Server 2011 (I.E. the main enterprise server with CMS and Report management and I guess RAS and all that). I figured this would remain untouched and queries would simply be made against it to retrieve/view reports e.t.c
    If install of the SDK on Crystal Server 2011 is indeed required should I expect any interruption to any of the core services after a restart. I.E. I'm hoping that none of the SDK objects would interfere with the existing server objects (in SAP Business Objects)Reason I ask is I note that much of the SDK install directories are similar to the existing Crystal Enterprise Server 2011 (Product 14.0.0)
    Is this temp folder to be manually created/configured or is it created by the application automatically to perform tasks. Or are you referring to the default C:\Windows\Temp directory and so saying that the application would try to use this for print and export tasks?Once I'm sure which I'd give the app pool user permission
    Printing is to be client side but I figured by default (with the Crystal Report Viewer) it would simply pool and print from the user's printer. This is how it works with the previously used URL reporting approach (viewrpt.cwr). Therefore a user can print the document from wherever they are with their own printer.We don't intend on printing from the server machine, but are you suggesting that a printer must be installed on server (which one web or enterprise server) for any client side printing to work.
    App pool is running in 32 bit mode
    Initially didn't get anything useful from fiddler but I'd try and look closer on your suggestion.
    It's also possible that some of my questions are a misunderstanding of APP vs RAS vs WEB, so please feel free to clarify. Currently I see the Web server as simply the created .NET SDK Application and RAS (Crystal Server 2011 e.t.c) as the existing fully established Application server which I simply pool for information.
    Thank you for your patience and advice,

  • How to work with gpib sriel polling procedure

    Hi all,
     i try to communicate with a Black Body, i give him a define Temperatur via GPIB, and it all works when I using the Commands as a String and work with GPIB-REAd and GPIB-WRITE. But if i want to read the status if the temperatur is almost stabil or not the describtion say " use the serial polling procedure syntax" and i don't really know how to filtering te rigth byte to get this information.
    I know that the third byte is the one I need and that it has to be ,1 but how? 
    Is it possible to get this information?

    I'd recommend posting in the correct forum for a quicker answer.
    -John Sullivan
    Analog Engineer

Maybe you are looking for

  • My flash player keeps crashing in only firefox and not in Chrome google

    I have reset firefox and unistalling and reinstalling and checked the updates but nothing works. I will be using chrome google from now as you don't care so much for the community as you say you do.

  • 10.1.2.0.2

    Maybe i'm having a bad day, but I can't seem to find the release notes for the new version of the Application Server. I want to know what fixes are in this release. (10.1.2.0.2) Can someone help me out please?

  • Illustrator CC 2014 is slow.

    It works fine until I have to work with a very detailed design. Then it is impossible to work with. The system will lag and hold and lag and hold and I can't click and drag with precision. Very frustrating, I've been reading others complain about thi

  • Problems with Upload record to Infotype 2010 together with Cost Assignment (PREF)

    Hi I create program using your guide http://scn.sap.com/people/aditya.palekar/blog/2010/01/19/uploading-a-pa-infotype-record-with-cost-assignment but I have two problems: If I call method "CALL METHOD ref2->modify_data" is obligatory parameter SECOND

  • Class Diagram not loading in VS 2013

    I can create a class diagram in VS 13, but it will not show. I get an error that says, "URI formats are not supported". I got this error in VS 12 and the solution was to open my website in file system mode. This solution is not working for VS 13. How