Complete PA transfer structure FI

Complete PA transfer structure FI
Message no. KF018
Diagnosis
Hi guru,
Cost element 410122 is not assigned to a value field in PA transfer structure FI.
Procedure
When you post directly to a profitability segment, PA transfer structure FI is necessary for assigning costs or revenue types to value fields in Profitability Analysis.
Check whether you are using the right cost or revenue element. If the cost/revenue element is correct, it must be transferred to the PA transfer structure.
You maintain the PA transfer structure in CO-PA Customizing under
"Flow of Actual Values -> Order and Project Settlement -> Maintain PA transfer structure".
Proceed

i assigned the cost element to PA transfer structure , still i am unable to posting the trasaction, i am getting same error,only revenue cost elements are unable to posting.
i had created cost element under revnues categary and cost element group are assigned under other income.
pls give me soluation it is very urgent.
Raju.

Similar Messages

  • Error in Order Settlement (KO88) Complete PA transfer structure A1

    Dear Gurus,
    In order to close a Production Order
    I am trying to Settle the order using KO88 after determining Variances using KKS2.
    The System is showing Error "Complete PA transfer structure A1".
    Pls guide what to do?
    Himanshu

    Go to KEI2 and assign any unassigned cost element used in the settlement to a  CAOP value field for transfer structure A1

  • Transfer structure copied into another structure ?

    Hello ,
    Iam trying to transport an transfer structure and iam getting an error and when i looked into the SE09 log i noticed somethng strange .
    I am not understanding why a transfer structure is copied into another structure as shown below in Bold  while transporting ??? is this somethng normal or somehtng happening strangely in my system ?
    "   Start of the after-import method RS_ISTS_AFTER_IMPORT for object type(s) ISTS (Activation Mode)
      <b>Transfer structure 80MATERIALM_CB activated under the name 80MATERIALM_CA</b>
      It is not necessary to copy dependent objects for transfer structure 80MATERIALM_CA
      <b>Object 80MATERIALM object version   not found in table</b>
      Activating Transfer Rules 80MATERIALM_CA ...
      3 Transfer Rule(s) of the transfer structure 80MATERIALM_CA removed from control table
      3 InfoObject(s) of the transfer structure 80MATERIALM_CA removed from control table
      Formulas have been saved
      Saving Structure /BIC/CACA80MATERIALM ...
      Activating Structure /BIC/CACA80MATERIALM ...
      Saving Structure /BIC/CCCA80MATERIALM ...
      Activating Structure /BIC/CCCA80MATERIALM ...
      Saving Structure /BIC/B0000015000 ...
      Activating Structure /BIC/B0000015000 ...
    <b> Object 80MATERIALM object version   not found in table</b>
      Start of the after-import method RS_ISTS_AFTER_IMPORT for object type(s) ISTS (Delete Mode)
      Start of the after-import method RS_ISMP_AFTER_IMPORT for object type(s) ISMP (Delete Mode)
      Start of the after-import method RS_ISFS_AFTER_IMPORT for object type(s) ISFS (Delete Mode)
      Start of the after-import method RS_ROUT_AFTER_IMPORT for object type(s) ROUT (Delete Mode)
      Errors occurred during post-handling RS_AFTER_IMPORT for ISFS L
      The errors affect the following components:
         BW-WHM (Warehouse Management)
      Post-import methods of change/transport request CD3K900107 completed
           Start of subsequent processing ... 20060821140054
           End of subsequent processing... 20060821140146"
    Your inputs are highly appreciated !!

    Gimmo,
    Do u mean i need to install and transport 0material to test system ??? coz currently i didnt install 0material in dev also thnking i dont need coz its an export datasource .
    Regards
    Deenu

  • Impact of Cost component structure on PA Transfer structure in SAP

    Hi All,
    We were using a single Operating concern and Controlling area for existing company codes. Now, we got a new company to be created all together a new company with the same chart of accounts.
    1. We have created Operating concern, COA, Company code..... and then completed the PA Transfer structure of FI-MM in KEI1
    2. I have created a new Costing variant in OKKN
    3. I have created the Cost component structure in OKTZ and assigned the new company code to it.
    When i go back and checked the PA Transfer structure for FI-MM, i see everything showing as blank.
    I have no idea the entire config got deleted.
    Do you have any idea how it happens and why it happens please?
    Also, will there be any relation b/n OKTZ and KEI1 and sequence to customize?
    Hope you understand my query.
    Appreciate your early response.
    Thanks,
    Narasimhulu

    Hi Ravi,
    Thanks for your response.
    I have created the FI-MM PA transfer structure for the new Controlling area. But after completing the Cost component structure and came back to check the PA Transfer structure, i was surprised since everything to deleted.
    I have no idea if we need to follow a sequence while doing these two activities (KEI1 and OKTZ).
    Thanks,
    Narasimhulu

  • Cannot activate 3.5 transfer structures after BI system copy

    We have just completed our first BI system copy (database-specific) from our BI-Production to BI-QA system to refresh database.  Have followed the Homogenous System Copy Procedure provided by SAP for Netweaver 7.0, DB2 for LUW.  Have been able to reactivate all 7.0 content, but 3.5 transfer structures cannot be activated because the transfer structure tables are not in the ERP QA source system.  All 3.5 transfer structures were working prior to the BI system copy.  Can anyone provide some guidance.  Have issued an OSS Note with SAP, but that can take some time to get resolution.  Is there any other resolution than converting 3.5 to 7.0 as this is half of our data?
    Thanks for your response!

    See SAP Note 493422.  Works like a charm.

  • Transfer structure

    Hi All
    i have to create a transfer structure.
    in dso and cube i have 27 fields.
    but in tranfer structure it is showing 50 fields.
    i have to select the 27 fields out of 50 or i have to activate 50 fields in transfer structure.
    Thanks & Regards
    krishna

    Hi,
    Basically when creating the transfer structure you need to map the transfer structure fields with the ODS/Cube fields that are present in the communication structure.
    You just need to Transfer the fields, that you have identified in Data source to the transfer structure and map the relevant fields in the Transfer structure.
    Once the mapping is done. Just activate the Transfer structure.
    Most importatnt would be to decide on the mapping between data source and Communication structure fields.
    Hope it helps!!!
    Regards,

  • Copy transfer structure transfer rules from one client to other client

    Hi
    Our R3 client 100 is mapped to BW client 100.
    R3 client 100 is source system in BW.
    As the master data is created by users in R3 client 200 we want to get the data from client 200 to BW. We dont want to replicate each datasource and do all stuff form scratch for client 200.
    Now the question is as we need to create transfer rules, transfer structure for all master data objects for client 200 in BW.
    1. Going to create R3 200 client in BW.--this is possible.
    2.Like create a transport connection in BW for client 200 for all master data infoobjects transfer rules transfer structure,process chain, infopackages..etc
    3.Do the source system mapping for new client 200.
    4.and then execute the process chain..
    What are the best ways to achieve this.
    creating all transfer structure and transfer rules only for those we are loading daily ..rather than all active ones.. How can I get the list of that master data that is loading daily.. and how easily can I create transfer structure..etc dependent objects in one go than manually.
    Any help or thoughts are appreciated..
    can anyone throw some light please....

    Hi,
    BW is not client dependent!!! When you sign on to BW, you have the client required. However, this field does not appear in any table (master data, ODS, cubes, whatever).
    This means that a same BW server with a single client can have multiple R/3 connections (for multiple R/3 clients).
    The database do not care about the client in BW. The data will be consolidated.
    So, you do not need any new client in BW, just two R/3 connections for your two clients.
    Regards,

  • Transfer Structure 'USES' Box

    Hello Friends
    I have a quick question for you.What is the 'USES' checkbox for in the Transfer Structure on the far left side, right next to the CONVE box.What does teh 'Uses' box signify and what does a green check present or absent there mean.
    Thanks.

    Hi Krish,
    The column 'USES' identify whether the field is used in the communication structure or not.
    To give you an example, lets say you have two fields KTOPL and HKONT in your extract structure of the data source and you have transferred these fields to the transfer structure, however you have mapped only KTOPL to an info-object where as HKONT is not mapped (in assign info-object section of transfer rules tab). That means KTOPL will only appear in the communication structure. If you check the USES column, you can see that it will be checked (a tick mark) for KTOPL where as "blank" for HKONT.
    Hope it clarifes.
    Thanks
    Soumya

  • Transfer Structure Status - Clock Symbol

    I have data in my ODS and have moved that data to the cube.  I have lost some of that data in the cube because of a delete of overlapping conditions.  I need to get that data back into the cube from the ODS.  I was going to load it from the ODS, but when I did, it only loaded a small portion of the packages from the ODS.  The reason is because after our ERP upgrade, we had to activate the InfoSource.  Now when you look at the Reconstruct tab in the ODS, the normal double green check marks have now been replaced with one check mark and a clock symbol.  It appears this data cannot be recovered.  Does anyone know if it is possible to recover this data and be able to move it to the cube.
    Thanks,  Keith J

    Hi Keith,
    When ever there is change to transfer structure in re construction tab we  will get that clock symbol. In your case as you are loading data from ODS to CUBE , from your first load from ODS to recent load there is change in your ODS object structure,that is the reason u are seeing clock symbol.if u are trying to reconstruct your requests it will pop up a message stating that to ignore the request click no,I think it will upload that request again,if not do an init load from ODS again and schedule your deltas regularly
    Regards
      KK

  • Transfer structure not active

    Hi ,
    in my process chain ,  it failed due to   error: Transfer structure is not  active.
    How to correc this?
    iam using BI 7.0
    regards
    sidartha

    Hi Siddartha,
    Try to activate the transfer structure using Pogram RS_TRANSTRU_ACTIVATE_ALL in SE 38. Give the Infosource & Source system name there & then execute.
    Hope this will help.
    ~!Dpak

  • Transfer Structure Creation

    Hi,
    I am trying to develop a tool to automate the transfer structure/info source creation. Does anyone know the table or function modules that create these?
    Thanks in advance.
    Alex.

    Hi:
    In transaction BAPI,
    check the BAPI BAPI_ISOURCE_MD_T_CREATE in the Data Warehousing BAPIs (Under InfoSourceMasterXfer).
    Thanks for any points you choose to assign.
    Best Regards -
    Ron Silberstein
    SAP

  • Transfer structure have two different tech names?

    Hi BW experts,
    we got issue in transfer structure which have two different technical names:
    ZCUSTOMER_DC and
    ZCUSTOMER_PS
    where zcustomer is the info source name.
    The impact: PSA data can't be accessed ...
    Any help and feedback is highly appreciated!
    Regards,
    Lilly

    Hi Dinesh,
    Thanks for your feedback.
    Unfortunately, this issue is thru our system landscape incl. production. If I try to delete the DS assignment I will lose data in the PSA, right?
    However, I did try to delete the DS assignment and delete the info source (the one which is available on dev only), failed, the message I get is info object xyz still being used in communication structure (I believe it must the TS with old prefix), deletion not possible.
    The problem is I am not able to delete the TS with old prefix , because it is not visible in system (AWB).
    Any further feedback appreciated

  • Transfer Structure Could not be Collected

    I am trying to activate some Business Content (CO-OM-CCA Costs & Allocations).
    In the “<b>Select Object</b>” Popup, after selecting the required object and I am pressing the “Transfer <b>Selection</b>”. Now I am getting the errors as below
    <i>1) Object 0VALUATION_TEXT               D6B100PCC (Transfer Structure,ISTS) could not be collected for object 0VALUATION_TEXT        D6B100PCC (Transfer Rules,ISMP)
    2) Object '0VALUATION_TEXT               D6B100PCC' (ISTS) of type 'Transfer Structure' is not available in version 'D'
    Message no. RSO252</i>
    This error is coming even I try to activate some DEMO Content (CO-PA Demo Cube).
    I am Grouping the objects with the Option “<b>In Dataflow Before and Afterwards</b>” with Collection Mode as “<b>Collect Automatically</b>”
    I am following the SAP Best Practices - BW Scenario
    https://media.sdn.sap.com/html/submitted_docs/Best_Practices/BW/html/index.htm
    Your help will be appreciated

    Hi Nathan,
    Make sure the objects are active. If so, then goto the infosource -> Extras (from menu) -> Object directory.. -> Transfer rules -> assign the package and it would ask for transfer structure later so assign the package to that as well.
    Bye
    Dinesh

  • Transfer structure  0BUS_AREA_TEXT_HA does not exist

    We are transporting InfoCube - 0FIGL_C10. which we had collected in a transport request with grouping as in Data Flow Before. This request ended with return code 12 with error message "Transfer structure 0BUS_AREA_TEXT_HA does not exist, Error RSAR 440 when handling objects with type R3TR ISTS"
    After this I collected the transfer rules of 0BUS_AREA_Text with grouping as dataflow before and after. the transport of this request also failed with return code 12 with the same error message "Transfer structure 0BUS_AREA_TEXT_HA does not exist, Error RSAR 440 when handling objects with type R3TR ISTS"
    has any one faced this error, please suggest the corrective action to be taken,

    hi all,
    I'm now getting the same error when I try to activate a created "transfer rules" for any type of DataSource of my cProject.
    "Transfer structure 0DPR_***********_DA does not exist
    Message no. RSAR440"
    please show me on step by step because I'm a new guy of this SAP.
    Thanks,
    Chuong Hoang
    R&D engineer of global cybersoft - vn

  • Transfer structure prefix error

    Hi all,
       When i active the transfer structure of any infosource of Ecc5.0.,I got an error message 'Transfer structure prefix for source system T90CLNT090 is not defined'. The source system T90CLNT090 is the current client of bw system.Any one who met the problem before,or have some idea about this,appreciate for sharing your experience.
    best regard,
    Eric

    Hi Natovian,
    Thanks again for ur time replying me!
    I tried to follow what ever u said.. but still unsuccessful.
    The Following is the screen that appears after I used SE37--> RSAP_BIW_DISCONNECT:
    http://farm1.static.flickr.com/212/495977912_6f890cad34_o.jpg
    I tried to see the entries for SLOGSYS & RLOGSYS using the TCODE SE16, following is the RSBASIDOC table screen which appears as:
    http://farm1.static.flickr.com/208/495995911_2213885c8e_o.jpg
    From the above table(screen) which combination do I have to use as entries to the following Screen(Using SE37 RSAP_BIW_CONNECT) :
    http://farm1.static.flickr.com/226/495977908_9c0ee51f29_o.jpg
    D I have to enter an entry for the RFC target system:??
    <b>Note:</b> I am Using SAP ECC 5.0  IDES version; have 3 source systems defined
            <b>1.</b> Source system T90CLNT090 with clinet 800 ( through which I run rsa1 to move on to BW 3.5 Administrator Work Bench screen) .Its a Combined Client I guess!! But basically I enter into R/3 System first before I jusm onto BW screens
           <b> 2 nd</b> and <b>3rd</b> are the Flat File Source Systems(SS_DEMOFF & SS_ODSFLAT) which I created by my own. and My use ID is SAPUSER for 800 Client to enter SAP.
    Do I have to have a BW source System as well do make this work??
    I have selecetd and tried the folloowing entries from the RSBASIDOC table :
    http://farm1.static.flickr.com/191/495977906_e10a056721_o.jpg
    and in the result, it says that the logical system already exists.
    I even tried using the flat table combination but the follwing is the result screen:
    http://farm1.static.flickr.com/226/495977956_073272c7ab_o.jpg
    I tried my level best to actually let you know, whats really happenening with my issue.
    Hope u will have a clear picture of my problem.
    Awaiting for ur precioius reply!!
    Vamsi.
    I tried defining a BW source system but got stuck in the middle filling up those details.
    Thanks
    <u></u><u></u>

Maybe you are looking for

  • Error 'Unable to open file' when downloading SAP Query to Excel

    Hi all I'm running a SAP Query which is set to download straight to a spreadsheet (Pivot Table / Microsoft Excel).  Intermittently it does not work -  apparently at random (at least, I've can't recreate the error at will). It does one of the followin

  • Would my I-Mac be able to handle Adobe Creative Suite?

    I was looking to get Adobe Creative Suite 3 (web design-standard) to start learning some website developement. I listed the system requirements below. My concern is the first two. Like I mentioned I have an I-Mac with the Intel based duo core process

  • Black MacBook 1,2 wifi issues

    My 2007 Black MacBook is unable to stay connected to wifi. It can connect right after I turn the computer on and for a few minutes after that, but then it gets disconnected and doesn't show any networks to choose from in the AirPort menu. To reconnec

  • Can't put notes on my ipod video?

    I have an Ipod Video, I don't know if that's what it's actually called or not, I got it about four years ago. Anyway, I've been trying for a while now to put .txt files on my ipod in the Notes category and can't seem to get it to work. I've been thro

  • Reminder email : GRC PC 2.5

    HI ALL, The Reminder email is  sending emails for same tasks as new tasks in the tool. Can you Please take note that only users receiving the reminders email are receiving the new tasks in SOX tool email Regards Siva