Component qt is missing

Sir, when i'm installing some apps then it says 'component qt is missing' and after installing the app not opens . Please help what i do...? for installing those apps.

Did you try to install a Qt Framework based app as explained in that other thread, for example Nokia Public Transport? I recommend to do this via the Nokia Suite on a Windows computer.
If that does not help, did you try to install the Qt SIS files, as explained in that other thread?
If that does not help, please
give one concrete example app (and source) so we are able to reproduce
dial *#0000# and give ‘Software version’
remove the battery and give us your (Nokia Product) Code (058…)
how much free space is left on drive C? Menu » Applications » Office » File manager » C » Free

Similar Messages

  • Calendar Display Issue / Unable to render component: ORA-00936: missing exp

    I am trying to display a range of dates in an APEX calendar, where the start and end date are in the record being selected.
    The SQL statement works fine in sqlplus, however when put into the calendar renders the error message "Unable to render component: ORA-00936: missing expression".
    select task, start_due + l - 1 "date"
    from calendar_tasks
    , (select level l from dual connect by level <= (select max(stop_date - start_date) + 1 from calendar_tasks))
    where
    l <= stop_date - start_date + 1 and
    task_status = 'SCHEDULED'
    Looking to understand this error in the calendar context and any possible solutions.
    Thanks!

    Try a column alias other than "date" and either not double-quoted or in upper case if double-quoted.
    Scott

  • 339 - Component 'Srcvw3.dll' missing / not configured correctly

    Hi,
    I'm trying to connect to essbase through FDM. I met this error in Tool > View error: "339 - Component 'Srcvw3.dll' or one of its dependencies not correctly registered: a file is missing or invalid."
    I moved ES11X-G4-H.xml to FDM Shared component and upsES11XG4H.exe to Essbase-client-32/bin folder. I also configure ARBORPATH and ESSBASEPATH to essbase 32 bit client directory.
    Please help

    The file you are referencing should be located in the Oracle\Middleware\Bin directory. Do you see this file here? If so, you can register it using regsrv32. The file and it's corresponding .lic file should be in this directory and registered from this directory.
    If you still receive the error, copy these two files to the FinancialDataQuality\sharedcomponents directory and register them using regsrv32 from this location.

  • WAD: Crashes with Run Time Error '339': Component 'formx.ocx' (missing)

    when using SAPGui 7.10 --> BW3.5x Web Application Designer the
    application fails to start and we get the following error message.
    Run Time Error '339': Component 'formx.ocx' or one of it's dependencies
    is not correctly registered: a file is missing or invalid.
    This works correctly on some machines but on others we get this error
    message. We have applied the latest patch.
    I suspect some non-sap software component has damaged my installation. How can I debug this? Re-installing SAPGUI doesn't do any good.
    Any ideas gratefully received.

    Check the following link. Is your issue related to this???
    Re: Error in WAD

  • Component Inspector Parameters Missing

    When I launch the Component Inspector for a Multiple Choice
    Interaction, there are no parameters listed under the Parameter
    tab. I am used to MX2004, where there was a table and I could fill
    in all my values for questions, answers, etc. But now I'm in Flash
    8 and that grid isn't there. When I click on the Parameter tab for
    a Component Inspector it is a blank slate. Can anyone help? I'm
    guessing there is some trick for me to see the fields that I could
    so easily fill in with MX2004?
    Thanks,
    Lauren

    Thanks. I expected such answer. But didn't expect Adobe made it silent. I hoped they at least explained something. And what component inspector panel does now? Nothing? Why then Adobe left it...   I remember good times with Macromedia...

  • MS/UB 12.0.1 HDR2x8 component has broken/missing footprint

    In MS, If I place HDR2x8 from the Master Database in a design and transfer to UB, it appears there is no footprint for this part.
    Regards,
    Who
    Attachments:
    HDR2x8 Footprint Missing from DB.zip ‏102 KB

    Hi,
    Thank you for bringing this to our attention, I will let the developer know about this.
    Tien P.
    National Instruments

  • Component Wizard is missing in UCM 11g

    Hi all,
    I'm running UCM 11g on Windows Server 2008 R2 Datacenter and I noticed that Component Wizard isn't installed neither in DomainHome nor anywhere else.
    Search in Windows Start Menu also doesn't bring any results.
    Is there any way to install it separately in existing domain or ECM Home?

    I actually found the Component Tool, but in:
    C:\Oracle\Middleware\Oracle_ECM1\ucm\idc\bin
    (this has ComponentTool.exe idcCommEnv.cmd, IdcShell.exe, Installer,exe, and a blank (pretty much) intradoc.cfg )
    NOT in the ...ucm/cs/bin dir.
    Of course when I run that, it fails with a !csIdcNameMissing which makes sense considering that is NOT where the UCM 11g server is and the intradoc.cfg isn;t configured.
    ANY ideas how this stuff got installed in different locations from the Standard??

  • CRM 2007 Upgrade - Component Type is Missing in Structure

    Hi,
    we found that structure /1CRMG0/CNBCCPSAP005 has empty data type for each of its component types. this causes error each time we try to activate the structure and we can't proceed the upgrade to 2007.
    we try to maintain the component type, but we encounter message "Object can only be created in package of namespace /1CRMG0/". even we try to maintain in the suggested package, it prompts error System setting does not allow you to change R3TR TTYP /1CRMG0/CCPSAP005001T. we can't proceed further at this point.
    we implemented sap note 0000817539 & 0000643510, but still no success.
    any lead is really appreciated
    JD

    Dear JD,
    hopefully you have already solved your problem. If not perhaps the following information is helpful:
    These Function Modules are created when the Sbdoc is generated
    using the report CND_MAST_GEN_TRANSFER_OBJECTS.
    Please check if the Sbdoc is generated correctly in your system or not.
    You can check this in transaction SBDM.
    The Sbdoc name is CNBCRMPRSAP005.
    If the Sbdoc is not created correctly please use the report above to
    generate and activate it.
    In any case if the problem is solved, please close the thread!
    Regards, Gerhard
    Moderator

  • Code could not be generated because an external component or driver is missing

    Greetings All,
         I've using Labview for a little over a year and I have an interesting situation with regards to Labview that I came across today.  When I left off yesterday (01/11/12) my TestStand sequence was compiling fine.  Today for some reason the compiler told me that one of the VI was broken or missing a sub vi.  When I made my way through all the sub vi's in the vi that seemed to be a problem I came across "Code could not be generated because an external component or driver is missing".
         The problem started on the computer (NI PXI-8101 with WinXP and Labview 2010) located in a PXI-1044 that is in my Test Stand.  I have a complete backup on my laptop and my desktop computer which both compiling successfully with no errors.  I tried installing the directory on another PXI-8101 and got a different set of results.  The first PXI-8101 gave 100+ errors in TestStand pointing to one of my vi's and the other PXI-8101 reported only one (1) error.  The vi is basically using DAQmx vi's to create a "write to one line" action.  I'm kind of stumped as to why it works on the laptop/desktop and not the PXI computers.  All four computer are WinXP professional and Labview 2010.  I saw somethings through google search engine but nothing conclusive.  I'm hoping that someone can give me an explaination as to what is causing the error as described.  Even if I copy over the directory it doesn't fix the problem.  Thank you in advance for an information you provide with this rather interesting problem that I've encountered.  If you require addition information let me know.
    Regards,
    Scott
    Solved!
    Go to Solution.

    Greetings Beau,
         Thank you for the reply.
         I loaded the offending VI into Labview (2010) with TestStand inactive.  Of course this was after I completely shutdown the computer and re-booted to ensure that nothing was resident in memory.  I've included a couple of the error list boxes in this post. 
         It comes down to a subvi that is two (2) subvi's deep.  All these vi's are doing is commanding a write or read to and from the PXI-6509.  When I check the VI at the level that has no broken run arrows (named below), nothing in the block diagram looks out of place as it should since these were installed by Labview installation.  The vi that uses these vi's looks total normal and its block diagram doesn't have anything out of the ordinary yet the run arrow is broken.  The odd part of this is that the top of the window that states the filename of the vi has an astrex at the end of the filename, even though nothing has changed in that vi.  
    Here is a list of the deepest level that has no broken run arrow:
    DAQmx Create Channel (DI-Digital Input).vi
    DAQmx Start Task.vi
    DAQMX Read (Digital Bool 1Line 1Point).vi
    DAQmx Clear Task.vi
    DAQmx Create Channel (DO-Digital Output).vi
    DAQmx Write (Digital U8 1Chan 1Samp).vi
         I guess the real question is what is the error message ("External component or driver missing") really telling me if all of the vi's look right.  I appreciate any information you can send my way that will give me a better understanding of where this error is coming from.  The program I developed had been running without a hitch for a month an all of sudden crash.
    Thank you for your time in this matter.
    Scott
    Attachments:
    Write to one port broken VI error list.JPG ‏47 KB
    Readfrom one line broken VI error list.JPG ‏46 KB
    Broken_VI_Error_Screen.JPG ‏56 KB

  • Hpqdirec.exe has stopped working; "This program requires a missing Windows component"

    Anytime I try to access the HP solution center I get a message pop-up. It is from Windows & says:  "This program requires a missing Windows component. "  "This  program requires  flash.ocx, which is no longer included in this version of Windows." How do i fix this????

    Dear Customer,
    Welcome and Thank you for posting your query on HP Support Forum
    It looks like you are facing issues with regards to one of the Windows component which is missing
    We will surely assist you with this issue
    Please click on the below shown link to find the steps involved in resolving the issue
    http://tinyurl.com/khb65xv
    You can Check your warranty Here to verify the status if required 
    Hope this helps, for any further queries reply to the post and feel free to join us again
    **Click the KUDOS star on left to say Thanks**
    Make it easier for other people to find solutions by marking a Reply 'Accept as Solution' if it solves your problem.
    Thank You,
    K N R K
    Although I am an HP employee, I am speaking for myself and not for HP

  • ADF Faces Component Missing

    I follow the instructions found here:
    http://www.oracle.com/technology/products/jdev/howtos/10g/adfjsf/how-to-adf-faces-10gjdev.htm?_template=/ocom/technology/content/print
    When I get to the section:
    Creating a simple ADF Faces application to test your configuration
    My component pallet is missing the following item:
    "JSF Core".
    What do I need to do to install this component?
    Thanks.

    I tried to download and follow the instructions for the early access release, and test the configuration of the project I built off of the .war file within jdeveloper but found that the .zip files you have to download from Sun are empty. I thought I would look here to see if anyone else had run into this problem. Check to see if the jsf-api.jar from the jsf-1_1.zip has anything in it.
    Scott

  • Device buffer overflow error and Log component missing

    I have some previous information in "Error device buffer overflow" post.
    I am currently running a windows XP machine with a 3.4 GHz
    processor and 3 GB of RAM. I tried using just one 9233 module with the
    cDAQ9172 and it worked. I added the second 9233 module and it started
    giving me the error. I checked the memory usage when acquisition is not
    started it was 868 MB and the CPU usage was 0-2%. When I started
    acquisition the memory usage did not change much it went to about 880
    MB and the CPU to about 100% and the error was displayed. The code shows the error that device buffer is overflowing when I use the program on a new machine even for one module with cDAQ9172 but when I switch it back to the original machine it works for single module but not for multiple.
    As the error suggests. I tried switching the update views in "Update
    signals while running" and "Prepare log data for viewing" off but it
    still did not help. If I switch both these off I wont be able to see
    what kind of impact data I am collecting. Please do correct me if I am
    wrong.
    I  need to colelct the impact data on a printer and I have
    a many locations on it that I need to collect data from.  Please
    suggest a solution for this problem.
          Also, if i try using the same project on some other machine it gives me an error indicating some log component files are missing from signal express and need to be installed. This happens when i transfer the project from one machine to another. 
    Thank you.

    Stu,
    You will still be able to print your data in a later step when setting the two options recommended by the error code.  What is likely happening when you try to move the project is that the project has log files still associated with it from previous attempts.  You should save a copy of the project and in that copy delete the log files, then try to move the project over.  SE projects are directly associated with the log files they create. This should allow you to move the project to a new computer.
    When you go to run your project, you should shut down as many background processes as possible, such as IM clients.  If you can disconnect from your network, I would suggest doing that and turning off any antivirus/anti-spyware software you have to free up resources.
    A couple of further questions:
    Are you connecting to a USB 1.0 or USB 2.0 port?  You should be able to determine this by opening the device manager on your computer and expanding "Universal Serial Bus" section. If any of the drivers have "Enhanced" in their name, you have a USB 2.0 port.
    Does this behavior repeat with any combination of the three modules?  For instance, does it work if you just have module one, module two, or module three install?  Do you still get the error if module two and three are used instead of one and two? (This will help determine if we are encountering a problem with the modules or with SE)
    Finally, if you create a project that contains only one step that only reads the data off of all three modules, do you still get the error? (This will help isolate the problem)
    Seth B.
    Staff Test Engineer | National Instruments
    Certified LabVIEW Developer
    Certified TestStand Developer
    “Engineers like to solve problems. If there are no problems handily available, they will create their own problems.”- Scott Adams

  • When starting the JSPM i get an error saying software component SAP_BUILDT

    software component SAP_BUILDT is missing from the system and will be generated using data from active usage AS.
    The next messege in the log tells me its been created successfully and I can see it the list of deployed components with an SP level of 0.0. I've got the correct SP level(11) for our system but can't specify it in the queue as a single SP. I already updated the rest but it missed BUILDT off.
    Any ideas?
    Its Netweaver 7.00 ABAP & Java

    Hello,
    Make sure you have the JSPM first updated to SP11
    and you have all the sP11 archives / SCAs in EPS/in directory
    Also, you must have the SPSTab.xml file generated for SP11 in the EPS/in directory.
    If jspm still fails, please paste the latest exception from jspm.trc file. and also check if the sdmlogs are getting updated under SDM\program\log directory.
    If they are, please paste the error/exception from the latest SDM log.
    Regards,
    Snehal

  • Adapter engine missing in the comm channal configuration

    Hi Experts,
    I am creating a File-IDOC scenario. While doing the configuration for the sender communication channel for file adpter the integration server is missing in the adapter engine drop down.
    But when i checked for other adapter type like Idoc and Http adapter, the Integration channel is available in the adapter engine drop down(only for these two apater type only, for other adapters also i am not getting the integration server).
    Can anyone help me regarding this, how to resolve this problem.
    Any SAPnotes or blogs for that.
    Help will be apprediated and rewarded as well.
    Thanks
    Manisha

    hi manisha,
    check the previous reply....the blog is nice
    and also check the note 764176
    check below
    1. Open the "Content Maintenance" view under "Administration" in the SLD editing interface. (in 7.10: the view "CIM Instances".) Select "XI Integration Server" from the drop-down menu and navigate to the associations of the integration server. Select the "XI Integration Server Logical Identity" association and delete the association by pressing the 'Remove' button.
    2. Switch to "Home" in the "Technical Landscape" view, and select the "Exchange Infrastructure" technical system type there. (as of 7.10: "Process Integration".) Select all domains and XI components for the host and delete these by selecting them and pressing 'Remove'.
    3. Start the J2EE server. After you restart the server, the XI components log on to the SLD again and create a new entity of the "XI Integration Server" class.
    4. To register the directory and repository again, you must also log on to the two tools.
    5. Under 'Technical Landscape' in the SLD, select the "Exchange Infrastructure" technical system type. (as of 7.10: "Process Integration") and check whether all XI components (Adapter Engine, Integration Directory, Integration Repository, Integration Server and Runtime Workbench/RWB) are logged on correctly. The Adapter Engine component may be missing. In this case, start the registration of the Adapter Engine as described in Note 1031321, step 2.
    6. Change again to the administration interface --> Content Maintenance (7.10: "CIM Instances") to the associations of the XI integration server.
                  Create a new association by pressing the 'New Association' button, select the "XI Sub-System viewed Application System" associations type here, and, in the next step, choose the BC system for the Integration Server. Save the association by selecting 'Associate'.
                  Create a new association by pressing the 'New Association' button, select the "XI Integration Server Logical Identity" association type here, and, in the next step, choose the business system for the Integration Server. Save the association by selecting 'Associate'.
    7. Under 'Technical Landscape' in the SLD, select the "Exchange Infrastructure" technical system type. (7.10: "Process Integration") and check whether the association to the application system is displayed there (in column "Application System", the business system on which the integration server runs should be displayed).
    8. To make the changed associations known in the directory, the SLD temporary storage must be deleted in the directory. To do this, log on to the Integration Directory and select the 'Environment --> Delete temporary storage areas for SLD data' menu option.
    reward  points if helpfull
    regards
    kummari
    Edited by: kummari on Jul 10, 2008 8:42 AM

  • Tree Component transparency

    when i try to make transpareny in tree component mouse events
    misses.what can in do

    I tried all different ways also but it didn´t work, but
    then I found the solution. You can do it in two ways...
    1: Convert the tree component to a graphic symbol and drag
    the Alpha down.
    2: Lets say that your tree is named thetree in "instance
    name" you can write: thetree._alpha=50; in the trees actionscript.
    It worked for me..
    Micke

Maybe you are looking for