Configuration of Cisco 3400 switch
what is difference between UNI & NNI ports in cisco 3400 12 CS switch how to configure them to make centralised connectivity with remote location
That error is "normal" because you are using a 3500 AP. This particular model of AP requires a wireless LAN controller (WLC).
You "cannot" load autonomous IOS into the 3500 for wireless service.
Similar Messages
-
How to configure multiple cisco 3750x switches
Hi All,
we recently bought 25 x 3750-48PS switches and need to roll them out with similar IOS and configuration.
I normally get a console to the switch from my laptop and do one by one.
is there a better way or software which can speed up the process ?
Thanks
QlRead this: ZeroTouch SmartInstall
If configured properly you can load the correct configuration & load the correct IOS in 20 minutes. The entire pile in 20 minutes! -
HI, I need to configure a 2960 switch at a client site. They have routers already been installed on site, one is for data traffic another is for voice. I have created two vlans on switch for data and voice. Now I couldn't get any idea what would be the default gateway on switch.
Please give me any suggestions.HI Leo,
Many thanks for your reply.
But there are two up-links going from Gi 0/1 and Gi 0/2. I have configured the S/W like below,
interface GigabitEthernet0/1
description UPLINK TO Data router
switchport access vlan 100
switchport mode access
interface GigabitEthernet0/2
description UPLINK TO voice router
switchport access vlan 100
switchport mode access
interface Vlan1
no ip address
no ip route-cache
shutdown
interface Vlan60
ip address 192.168.1.253 255.255.255.0
ip helper address 192.168.1.1
no ip route-cache
interface Vlan100
ip address 172.16.1.253 255.255.255.0
ip helper address 172.16.1.1
no ip route-cache
I have used IP helper address, but I am getting some connecting issues on PCs and IP phones. Please suggest me, Can I manage it with two uplinks with different IP addresses.
Thanks in advance. -
Embeded Event Manager on cisco 3560 switch
Can someone help me please? I have EEM configured on cisco 3560 switch. The configuration is below. I want that switch inform me through email when device with particilular IP address become unavailable. For some reason this configuration is not good and I can't tell why. I already try to debug this with debug event manager action mail but didn't see any output .
ip sla 11
icmp-echo ip address
frequency 20
ip sla schedule 11 life forever start-time now
event manager applet device-TEST
event snmp oid 1.3.6.1.4.1.9.9.42.1.2.9.1.6.11 get-type exact entry-op lt entry-val "2" poll-interval 20
trigger occurs 5 period 120
action 02.0 mail server "ip address" to "[email protected]" from "[email protected]" subject "device is down"The mail part looks good, I'm not sure you are hitting the trigger right.
Why not do a track on the ip sla instead of the snmp stuff?
Here's a good example of that.
https://learningnetwork.cisco.com/blogs/network-sheriff/2009/06/19/writing-your-first-eem-applet -
How can i configure hsrp in cisco 3850 switch please guide me
how can i configure hsrp in cisco 3850 switch please guide me
Hi Mauleshg,
Please the below mention link to configure Hsrp hope this will help you.
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst3850/software/release/3se/ip/configuration_guide/b_fhrp_3se_3850_cg/b_fhrp_3se_3850_cg_chapter_010.html
Br.
Mohseen Patel -
Cisco 4507 Switch - Clients are unable to renew the IP Address
Hello .
i have cisco 4505 core switch with different DCHP pool bind with different Vlan
clients from one DHCP pool are unable to renew the ip address . while others DHCP pools configured on the same switch are working fine .
please Advice .Hello Leo ,
Below are the requested info :
DA-V02#sh ip dhcp binding | begin 10.1.X
10.1.X.21 0184.2b2b.adfc.74 Infinite Manual
10.1.X.22 0100.1ec9.7820.fd Infinite Manual
10.1.X.23 0100.1aa0.6f32.f7 Infinite Manual
10.1.X.24 0100.1ec9.782d.b0 Infinite Manual
10.1.X.26 01f0.4da2.25e7.b3 Infinite Manual
10.1.X.27 0100.1aa0.7872.71 Infinite Manual
10.1.X.30 0118.0373.2957.d4 Infinite Manual
10.1.X.31 01b8.ac6f.a4d2.03 Infinite Manual
10.1.X.32 0100.2170.407c.96 Infinite Manual
10.1.X.33 0100.1ec9.6ba3.d5 Infinite Manual
10.1.X.34 0100.2170.407b.c2 Infinite Manual
10.1.X.35 0100.1ec9.782a.11 Infinite Manual
10.1.X.36 0100.1ec9.6c31.32 Infinite Manual
10.1.X.37 0100.26b9.c283.09 Infinite Manual
10.1.X.38 0100.2170.407c.59 Infinite Manual
10.1.X.39 0100.2170.407c.74 Infinite Manual
10.1.X.40 0100.1ec9.6c33.2c Infinite Manual
10.1.X.41 0100.1aa0.6f1f.6d Infinite Manual
10.1.X.42 0100.1ec9.6b9e.d8 Infinite Manual
10.1.X.43 0100.1ec9.6a8b.cf Infinite Manual
10.1.X.44 0100.1ec9.782c.f3 Infinite Manual
10.1.X.45 0100.2170.4074.cf Infinite Manual
10.1.X.46 0100.1ec9.6c38.38 Infinite Manual
10.1.X.47 0100.1ec9.782c.5b Infinite Manual
10.1.X.48 0100.2170.4077.06 Infinite Manual
10.1.X.49 0184.2b2b.ae10.f0 Infinite Manual
10.1.X.50 0100.2170.407c.e6 Infinite Manual
10.1.X.51 0100.1e4f.4f31.14 Infinite Manual
10.1.X.56 0100.1ec9.783e.b1 Infinite Manual
10.1.X.57 01b8.ca3a.a2d3.b0 Infinite Manual
10.1.X.59 019c.934e.1811.d8 Infinite Manual
10.1.X.80 019c.934e.1810.cc Infinite Manual
10.1.X.87 0100.1ec9.6c1e.e3 Mar 17 2014 10:10 PM Automatic
10.1.X.98 0014.38e1.c9a0 Infinite Manual
10.1.X.114 01b8.ca3a.a31b.fe Mar 18 2014 12:57 AM Automatic
10.1.X.204 0100.1ec9.7829.5e Mar 17 2014 10:10 PM Automatic
10.1.X.205 0100.1ec9.77ea.a7 Mar 17 2014 11:46 PM Automatic
10.1.X.206 0184.2b2b.adfc.c1 Mar 17 2014 10:47 PM Automatic
10.1.X.207 01a4.badb.f89e.90 Mar 17 2014 11:39 PM Automatic
10.1.X.208 0100.1aa0.6f31.6c Mar 18 2014 01:01 AM Automatic
10.1.X.242 0108.0037.8c00.ea Infinite Manual
10.1.X.243 0000.aac1.636f Infinite Manual
10.1.X.244 0800.379b.21f0 Infinite Manual
10.1.H.205 0100.2584.1870.11 Mar 18 2014 10:23 AM Automatic
10.1.H.206 0100.2584.186f.32 Mar 18 2014 10:29 AM Automatic
ip dhcp excluded-address 10.1.X.1 10.1.X.63
ip dhcp excluded-address 10.1.X.240 10.1.X.254
ip dhcp excluded-address 10.1.X.242
ip dhcp excluded-address 10.1.X.243
ip dhcp excluded-address 10.1.X.244
ip dhcp excluded-address 10.1.X.130
ip dhcp pool floor2_users
network 10.1.X.0 255.255.255.0
default-router 10.1.X.1
dns-server 10.9.57.21 10.8.57.22
domain-name corp.ank.ad
lease 0 12
interface VlanX
ip address 10.1.X.1 255.255.255.0 -
Converting Eth port to FC port in a cisco 6001 switch
Hi,
Back to forum after a long time. I have one issue to discuss regarding cisco 6001 switch. We purchased a new 6001 switch. Want to convert some of the Ethernet ports out of total 48 to FC to join the switch into a existing fabric.
cisco Nexus 6001 Chassis ("Norcal 64 Supervisor") - This is what H/W version look like from show version command.
In the past, we have quite a few Cisco 5548UP switch and the way convert the Ethernet port into FC port is, by going to correct slot/module and then
(config)# slot 1
(config-slot)# port 41-48 type fc
Then "reload" willl complete the conversion. But in the new 6001 switch, it throws the following error when above command is typed. We have full license for the switch including FC_FEATURES_PKG
"ERROR: Module type doesn't support this CLI"
We are running firmware : 6.0(2)N2(2)
Any help in this regard will be helpful.
Thanks.I have this exact same error;
show ver
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
Copyright (c) 2002-2014, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
Software
BIOS: version 1.5.0
loader: version N/A
kickstart: version 7.0(5)N1(1)
system: version 7.0(5)N1(1)
Power Sequencer Firmware:
Module 1: version v4.0
Module 2: version v4.0
Fabric Power Sequencer Firmware: Module 1: version v4.0
Microcontroller Firmware: version v1.2.0.5
QSFP Microcontroller Firmware:
Module 2: v1.3.0.0
SFP Microcontroller Firmware:
Module 1: v1.1.0.0
BIOS compile time: 12/29/2012
kickstart image file is: bootflash:///n6000-uk9-kickstart.7.0.5.N1.1.bin
kickstart compile time: 10/29/2014 22:00:00 [10/30/2014 11:46:56]
system image file is: bootflash:///n6000-uk9.7.0.5.N1.1.bin
system compile time: 10/29/2014 22:00:00 [10/30/2014 11:47:58]
Hardware
cisco Nexus 6001 Chassis ("Nexus 64 Supervisor")
Intel(R) Xeon(R) CPU @ 2.00 with 8238120 kB of memory.
Processor Board ID FOC181506P3
Device name: xxxxxxxxxxxxxx
bootflash: 7823360 kB
Kernel uptime is 3 day(s), 17 hour(s), 25 minute(s), 49 second(s)
Last reset at 642096 usecs after Fri Feb 27 15:24:40 2015
Reason: Disruptive upgrade
System version: 6.0(2)N2(3)
Service:
plugin
Core Plugin, Ethernet Plugin, Fc Plugin
xxxxxx# conf t
Enter configuration commands, one per line. End with CNTL/Z.
xxxxxx(config)# slot 1
xxxxxx# port 47-48 type fc
ERROR: Module type doesn't support this CLI -
Trouble with Windows7 and Gigabit link on Cisco 3560X switch
Hello,
In my company, we are using Cisco IP Phones 7945G (with 2 gigabit network ports) and Cisco 3560X-48P (1GB ports) switches for our users.
Our client computers are running on Windows 7 SP1 (64bit - Enterprise edition) and are connected behind the IP Phone. We use a "Boradcom
Xtreme Gigabit" onboard network card on the computers. All ports (on the switch site and IP Phone side) and on the network card of the computer are configured in "auto negotiation". Duplex and speed are set to "auto".
We tried now to deploy a new engineering software and we are facing a very strange problem. This means that the engineer software fails to download some files from the server. We are using a flat network, all the servers and computers are on the same network segment with no firewall inbetween.
The firewall and Anti-virus on the computers are configured to allow all incoming/outing connections.
To troubleshoot, I tried to change all the network cables but I still get same result --> download fails.
I connected the client computer directly to the Cisco 3560X switch, without the IP Phone and I get the same result.
I installed a separate network card from INTEL (Intel PRO1000 PT) but I get the same result.
As last test, I have connected to same client computer directly to a Cisco 2960-8TC switch (100Mbit; auto negotiate) and here is working fine. The software successfully downloads all the files from the server.
If I connect the computer behind the Cisco 7945 IP Phone, set the speed and duplex of the PC-Port on the Cisco IP Phone 7945G to "100MBit/full duplex" is also working fine.
Is there any know issue with Windows7 and Gigabit network connections?
Do I need to set any Registry key on my Windows 7?
The firmware version of my Cisco 3560X-48P switch is 12.2(53)SE2; do I need to update it?
The firmware version of the IP Phone 7945G is 9.2.1.
Thanks in advanced for your help.
Marc HoffmannHello, Thanks for your answers. First of all, I have updated the firmware of my Cisco Catalyst 3560X-48P switch to the version 12.2(55)SE5. Unfortunately, this did not solve my problem. As second step, I ran an TDR test on my 3560X switch but I do not get any result. The "Pair status" always says "not completed". Even if I wait for 5 minutes, the status remains at "Not completed". Am I doing something wrong ? To do the TDR test, I use the commande "test cable-diagnostics tdr interface gigabitEthernet 0/XY". For your information, the port gigabitEthernet 0/XY is in a "Connected" status when I run the "show int status" command. Jeff, I think there is no issue on the server side, because if I connect my workstation on a 100MB switch (example Cisco Catalyst 2960-8TC-L) the application works absolutely fine. Also, if I run the application locally on the server, it works fine. As next step, I will connect the workstation directly on our backbone switch and try the same test. Is there perhaps any Registry key in our Windows7 which could cause this trouble? If you have any other ideas or options, please let me know. Thanks a lot, Marc Hoffmann
-
Remote Command Tool for Cisco Routers/Switches
Is anyone aware of any tools or scripts out there which allow preconfigured commands to be remotely run again Cisco Router/Switches and display the output result?
I'm looking for a tool which I can give our Service Desk personnel that will allow them to select from a list of commands enter a target IP Address of a router/switch and then the tool will display the vlan table or the running config of a particular switch-port so they can see if its configured on the correct data vlan or its missing its voice vlan etc.
For example a Service Desk Operator needs to check what vlan a switch-port is on. So they open the tool, enter the switches IP address and the port number and select an option like "display a switch-ports vlan" and the tool will login into the switch in the background run a show command on the switch and then output the result.
Thanks.Check out rConfig. You will be able to run multiple instances of it i.e. one instance for your standard configuration backups and another for more specific configuration downloads info like show vlan bri commands etc for service desk staff to view.
You could also use the IOS menu function and create menus or role based access on each of your devices for your users.
Regards
Stephen
==========================
http://www.rConfig.com
A free, open source network device configuration management tool, customizable to your needs!
- Always vote on an answer if you found it helpful -
Multiple context on Cisco Content Switching
Hi Everyone
I had new case with Cisco Content Switching design. The current network has two Cisco Content Module (CSM) and each of them response for switching content on one Vlan.
Now i want to reconfigure it, to meet the redundancy requirement. But i don't know Cisco Content Module have same idea of design with ACE on Route Mode.
I want configure CSM with two or more vlan pair in routed mode and it can HA between each other.
Thanks
Phai La QuyHi Phai,
Yes you can configure CSM in routed mode with clients in one VLAN and server in another. Pasting the link for your reference. You can find more in routing and switching guide.
http://www.cisco.com/c/en/us/support/docs/interfaces-modules/content-switching-module/26220-csm-config.html
Regards,
Kanwal -
Cisco 3850 Switch getting message %SPI_FC-3-HIGH_WMARK_REACHED
Hi Team,
We have one Cisco 3850 Switch installed at the Customer site and getting the message as below,
Mar 28 10:57:11.578: %SPI_FC-3-HIGH_WMARK_REACHED: Number of messages in the queue for channel 9 has reached maximum.
-Traceback= 1#830db5fd318976b0280defe233875463 :10000000+153F71C :10000000+B5E9B0 :10000000+B5EBA4 :10000000+3CC5CC :10000000+3CD0B4 :10000000+39AB00 :10000000+27CDD2C :10000000+7C7814 :10000000+27AC29C
.Mar 28 10:58:31.585: %SPI_FC-3-HIGH_WMARK_REACHED: Number of messages in the queue for channel 9 has reached maximum.
-Traceback= 1#830db5fd318976b0280defe233875463 :10000000+153F71C :10000000+B5E9B0 :10000000+B5EBA4 :10000000+3CC5CC :10000000+3CD0B4 :10000000+39AB00 :10000000+27CDD2C :10000000+7C7814 :10000000+27AC29C
--More-- .Mar 28 10:59:51.586: %SPI_FC-3-HIGH_WMARK_REACHED: Number of messages in the queue for channel 9 has reached maximum.
-Traceback= 1#830db5fd318976b0280defe233875463 :10000000+153F71C :10000000+B5E9B0 :10000000+B5EBA4 :10000000+3CC5CC :10000000+3CD0B4 :10000000+39AB00 :10000000+27CDD2C :10000000+7C7814 :10000000+27AC29C
Please suggest the meaning of these messages and suggestion for resolution on the same.
Attaching show version, show logging for this Switch.
Regards
AshutoshHi Akilhasan,
The switch is hitting a bug which is currently under investigation. The latter implies there is no official workaround, but my suggestion would be that you consider reloading the switch outside of business hours (considering preventive measures i. e. back the configuration up, save changes, etc.).
The most stable version and recommended per Cisco is 03.03.03. There is newer 03.06.00 available, just released past June, so you may consider as well upgrading the IOS, of course under a properly carried out risk assessment, and you can roll back if something unexpected occurs. I would suggest doing so only if you have a solid knowledge of the customer's network and business needs.
Hope this helps.
Kind regards,
- Ed -
Apple wired Dot1X - on Cisco 2950 switches
Hi, I have an issue with Apple desktop computers running 10.7 and 10.8 MacOS.
The problem is that we have only 2950 switches and we are very limited with what we can do on them, so we wanted basic DOT1X user authentication and VLAN placement. Those two are working great, except when user logs off, Mac stops sending DOT1X and port becomes unauthenticated. We alleviated that issue by using guest-vlan for failed dot1x authentications, but now we have a problem that once user logs in, there is no session change on 2950 and it doesn’t even try to authenticate user until we bounce the port.
Is there any way to fix this, on Cisco switch or Mac computer? One of the things that crossed my mind is bouncing port on Mac PC using some kind of logon script?
Has anyone else had this issue and was able to solve it?
Thanks.Hello Align,
Cisco 2950 switch with 12.1(9) supports 802.1 x authentications. As you are saying that you already configured 802.1x authentication and its working fine. I think there is problem with your MAC OS configuration. Please follow the below link to configure 802.1x on Apple.
http://support.apple.com/kb/ht3326 -
Dears,
We re using Cisco 3400 in out network with Metro Ip Access 12.2(53)Version.
The issue is that we Plug SFP SFP-GE-L 10-2144-01,1000 BASE LX/LH and loop the Fiber Patch Cord we do not recieve any packet.
Even if we connect to other Cisco we are unable to recieve packet even the Interface status Shows UP..
Need your expert advice.
Thanks
JawwadHi Jawwad,
do you mean that the issue occurs ONLY if you use SFP SFP-GE-L and not if you use other SFPs?
If this is the case, which other SFPs did you try?
What do you see on 'show interface gix/x" after you send some traffic? can you attach the outputs?
All ports are affected or just some?
Can you attach the port configuration?
regards,
Riccardo -
Manage Cisco catalyst Switch 2948G.
My task is to manage Cisco 2948G switch using NMS.I am supposed to use CISCO-STACK-MIB.I just need the following hierarchy info of Cisco 2948g switch.Please tell me the number of components in each
Chassis
|-->Slot
|-->Module
|-->Port
As per my knowledge,it has 48 ports of "fixed configuration" and two ports with GBIC interface.how are they arranged ?if it is fixed configuartion ,then there is no modules,slots??
When i populate the data in CISCO-STACK-MIB,
1)Should the value of "portModuleIndex" in the MIB be "1" for all 50 ports??
2)Should the value of "portIndex" be 1,2,3...50 for the ports?
3)What should be the value of "moduleIndex"?
The following link deeals with it but not clear.
http://www.cisco.com/en/US/tech/tk648/tk362/technologies_tech_note09186a0080094a9a.shtml
Kindly load the CISCO-STACK-MIB available at ftp://ftp.cisco.com/pub/mibs/supportlists/wsc2948g/wsc2948g-supportlist.html
analyse and help me.Please post the question to "Network Management" under "Network Infrastructure." You will find SNMP and MIBs expertise there.
-
We have OpenVMS running on a Streams Environment OSI protocol connecting to a Cisco 3548 switch with fiber GBIC trunk ports. The ports display link lights, but network connection to a Windows NT 4.0 Server (Service Pack 6) with Allied Telesyn NICs (half-duplex) fails with LAN Connection Errors reported on DHCP Client Computers. However, when the Switch is bypassed, and directly connected to the Server, problem disappears. Do I have a duplex mismatch problem or IOS release issue?
You have to check to see how the switchports are configured , by default the speed is auto/auto , if the ports are hardcoded to a specific speed and duplex then you probably have a speed/duplex mismatch. Match both ends of the links , if nics are auto then the switchport should be auto . If the nics are hard set to a speed/duplex then you have to set the switchport the same.
Maybe you are looking for
-
Dear Expert Please help me on below scenario. My client is raising PO. The Material cost is 100 INR. While goods receipting, Knowing that material cost is 120 INR. So i am changing the Base value 100 to 120 INR in detail data (Excise item) tab while
-
Customizing Top level navigation
Hi, I have requirement where in i have to customize the top level navigation. Insted of hyper links display i have to show them like buttons, not exactly buttons but the hyperlinks shown for the navigation should be removed. Is it possible to show wi
-
Project id (PSPHI) field
Hi experts I had created the generic extractor using the FM which include the Project id (PSPHI) field its the Numc data type of length 8. for this i have created the Z** info object with ABPRJ Conversion Routine in the length is 30 of type char. Iss
-
Error during migration from Windows 2000 to RH Linux AS 4
Hello all, Am trying to perform a migration of a 11.5.10 instance from Windows 2000 to RH AS 4. Am following steps listed in the doc id 238276.1. Have completed all steps, but autoconfig completes with the following error: INSTANTIATE PHASE imtjserv.
-
HT5569 i had the ipad reset all factory settings and now I cannot get on wifi please help
I reset the factory settings and now I cannot get onto the wifi