Configuring dual-links on catalyst 3750

I've dual-links (laser and Fiber optic media) to connect my office and colocation. both of using catalyst 3750, there are also 4 VLAN. the problem are Fiber optic provider only allow 1 VLAN to connect my network to colocation, when the Laser drop, Fiber optic can't send traffic to colocation.
is there any clue for this problem...?
thanks,

Hey,
Please give the Show config output from both the switches. Would like to see the config on both the ends.
regards,
-amit singh

Similar Messages

  • Catalyst 3750 12.2(25)SD1 and dual nics

    When a Catalyst 3750 stack master fails or leaves the stack, a cross-stack EtherChannel in trunk mode running Link Aggregation Control Protocol (LACP) protocol might stop forwarding traffic on some VLANs.
    The workaround is to enable the stack-mac persistent feature by using the stack-mac persistent timer global configuration command. You can also use the shutdown interface configuration command and then the no shutdown command on the EtherChannel interface.
    Network Infrastructure: LAN Routing and Switching
    I have upgrade a Catalyst 37024 TS 2 switch stack to 12.2(25)SED1 from 12.1(14)EA. The switch has an Alpha Server Custer connected to it the cluster has two servers each having two nics . There is a active server which has an application IP address and each server has a Server IP address one nic active ata time.
    All worked ok upto the upgrade. Now every night when the backup runs noone can access the application ip address or the acive server address but te offline server is pingable. This is only for devices outside the serrver VLAN. Devices within the server VLAN can hapily ping any address.
    I thought this was arouing issue but all looks ok and the offline server can be pinged from any where.
    the active server nics areon 1/0/20 and 2/0/24
    Any one have any ideas?

    I forgot to add if I shut both interfaces an then do a no shout on both the issue is resolved until the next night.

  • Configuring a Catalyst 3750

    I want to configure a route between Port1 and Port2 and another route between Port3 and Port4 of the catalyst 3750. Is that possible and how can I do this?

    Configure the ports to be layer 3 just like any other router. But, you might be better off creating SVI or interface vlan and assign the ports to accordingly to the SVI and just enable ip routing which should be enabled by default.

  • Monitor flickering with T500 with accell dual-link-​dp adapter

    I have an HP LP3065 30 inch external monitor, 2560x1600, that I'd like to drive off my T500. I am now on my second accell display-port to dual link dvi adapter and am still getting periodic blackouts of the monitor which last less than a second. At first I thought it was due to insufficient power to the adapter provided through the usb port, as has been reported in various places, so I got a high powered usb hub with ac adapter. Didn't help. Accell said it must be a lenovo problem and that they had "reported" the issue to lenovo. I exchanged the adapter for a new one on the off chance it might be a manufacturing issue but the new one is just the same. Has anyone gotten this configuration to work properly? If so, what dp-dual link dvi adapter are you using? Any special adjustments to your settings? I have the ATI Mobility Radeon 3650 card. All drivers are current as is the BIOS.
    Solved!
    Go to Solution.

    Hi greigite,
    Welcome to the Lenovo forum!
    Is the Accell B087B-002B the adapter you are using? I haven't used such an adaper, but it looks very nice. It gets excellent reviews on Amazon, though at least one reviewer recommended connecting it to a powered USB hub to eliminate display flickering. You've done that already -- suppose you could try a different powered USB hub on the off chance that the first one is defective, but that seems unlikely.
    You might have a look at the power-saving features of your ATI video card. I think you can right-click on your desktop to start "ATI Catalyst Control Center" (if not, think you can find it in the Start menu). One of the panels of CCC lets you adjust power saving profiles, and whether to reduce the vertical refresh rate below the usual 60 Hz. You could try turning the vertical refresh rate reduction feature off, and maybe try some different power-saving profiles.
    How often does the flickering occur? Like, once every 20 minutes, or less often?
    Best regards,
    Frank
    Results of Your Ideal Business-Class Laptop survey, concluded 2009-07-29.
    Did someone help you?
    Say thanks! with a kudo.
    Even better: Pay it forward, help someone else.

  • /31 on Catalyst 3750 routed port

    I've discovered the feature 'Using 31-Bit Prefixes on IPv4 Point-to-Point Links' and I'm interested in implementing it on a point-to-point uplink network that terminates on one end to a Catalyst 3750 routed FastEthernet port ("no switchport").
    I can enter the IP address in the interface config (172.16.100.0 255.255.255.254), and I get the warning "% Warning: use /31 mask on non point-to-point interface cautiously". Since I can guarantee that this is in fact a point-to-point uplink to a Layer 3 device, can I safely ignore the warning? Is there any way to configure the interface explicitly as a Point-to-Point interface instead of a broadcast interface?
    Thanks!
    -Mason

    Hi,
    It doesn't appear the error is platform specific. I am getting the same error in my lab 2600 when configuring a /31 bit mask.
    You would use the /31 bit mask only on a p-t-p interface hence, you don't need to tell the interface it's a p-t-p interface. I don't know of any generic command to tell the broadcast interface that it's a p-t-p interface. There is a OSPF command but that doesn't have anything to do with this setup.
    R2(config)#int e0/0
    R2(config-if)#ip add 1.1.1.0 255.255.255.254
    % Warning: use /31 mask on non point-to-point interface cautiously
    R2(config-if)#^Z
    R2#show run
    *Mar 1 18:20:21.795: %SYS-5-CONFIG_I: Configured from console by console int e
    /0
    Building configuration...
    Current configuration : 78 bytes
    interface Ethernet0/0
    ip address 1.1.1.0 255.255.255.254
    half-duplex
    end
    R2#show ip arp
    Protocol Address Age (min) Hardware Addr Type Interface
    Internet 1.1.1.0 - 0004.dd85.eee0 ARPA Ethernet0/0
    R2#ping 1.1.1.1
    Type escape sequence to abort.
    Sending 5, 100-byte ICMP Echos to 1.1.1.1, timeout is 2 seconds:
    Success rate is 80 percent (4/5), round-trip min/avg/max = 1/3/4 ms
    R2#show ip arp
    Protocol Address Age (min) Hardware Addr Type Interface
    Internet 1.1.1.1 0 0004.dd85.e9c0 ARPA Ethernet0/0
    Internet 1.1.1.0 - 0004.dd85.eee0 ARPA Ethernet0/0
    HTH
    Sundar

  • Catalyst 3750 interface explaination

    Dear Sir,
    I don't understand as follows :-
    1.) why on Catalyst3750 interface fastethernet 1/0/1 ?? <--- what's the meaning of 1/0/1 ?
    2.) what's the meaning of no mdix auto?
    Please explain and advise.
    Thank you.

    The 3750 has many interesting features, I recommaned you go through before you connect your switches in a production environment.
    Basically, you should provision your stack master with the number of switches and their types. You could provision as well the interfaces with their corresponding configurations, even though the other elements are still not connected yet. This way, you ensure, when you add a provisioned element with the right number, it will take exactly the provisioned configuration you've already set on the master,... as well when changing an element with an other, when moving it,... you will have just to provision its number and then connect it to the stack while is not yet powered on.
    Second, it is recommanded to set priority to each element, this way you will have a deterministic configuration and you know in advance which one will be reelected as master in any sitution.
    If no provision is set on the stack master, when you connect a switch, it has by default the number "1", in this case the newly added switch will take the lowest switch number available (2).
    1.) 1/0/1 --> so the second will be 2/0/1.
    And to address its ports you tape: 2/0/1, 2/0/2, 2/0/3,2/0/4,...2/0/24,...
    How to stacked both of the catalyst 3750? just purchase one stackable cable to link both of them and will it automatically configure the 2nd switch from 1/0/1 to 2/0/1 after we plug in the stackable cable into the 2nd switch.
    For large deployment I recommand the switches to be provisioned manually: Before stacking the switches:
    1/ power on the switch that will be the stack master, then wait till it will be in "Ready" state by issuing "show switch detail" command.
    2/ Provision the stack master with the desired stack configuration (numbers of switches, types of switches and interfaces configurations).
    3/ Reload the stack master.
    4/ Provision the second switch with its number and type.
    5/ Power off the second switch afetr having saved its configuration.
    6/ Stack the second switch to the stack master.
    7/ power it on. It will take the provisioned configuration on the stack master.
    The advantage of this procedure is that switches could not be renumbered while stacked and running.
    Repeat steps 4 to 7 for each new element having been provisioned in the stack master.
    Do not forget to save after each step.
    2.) so i put "no mdix auto" on catalyst 3750, what's the meaning and impact?
    no mdix-auto will disable the advanced feature of abstructing the type of cable (staight throu or cross over). You will downgrade to the standard interfaces specifications. In fact, mdix-auto (activated by default) permits to not to have the "overhead" of distinguishing crossover and straight throu cables, the interfaces will adapt automatically to the type of cable.
    An other advantage of this function is that it opimises (combined with other functions) error and recovery procedures in layers 1 and 2.
    Mohamed BEN HASSINE

  • VLAN trunking from Cisco Catalyst 3750 to Cisco SF300-48P issue and related

    Hello expert,
    I'm having difficulties to configure VLAN trunking between Cisco Catalyst 3750 switch with Cisco SF300-48P switch and my workstation unable to get any DHCP IP from our DHCP server via Cisco SF300-48P switch. Below is the snippet of configuration on both switches:
    [Cisco Catalyst 3750 Switch]
    interface GigabitEthernet1/0/45
     description NCC-CC-1stFlr
     no switchport trunk encapsulation dot1q
     no switchport trunk allowed vlan 101-103
     spanning-tree portfast
    [Cisco SF300-48P Switch]
    interface fastethernet48
     spanning-tree link-type point-to-point
     switchport trunk allowed vlan add 101-103
     macro description switch
     !next command is internal.
     macro auto smartport dynamic_type switch
    interface fastethernet29
     switchport mode general
     switchport general allowed vlan add 103 tagged
     switchport general pvid 103
    Are these are correct? Kindly advice!
    Thank you very much!
    Regards,
    Alex

    Hi Alex,
    for the trunk port on Catalyst on port GE 1/0/45, we need to enable the trunk and for on encapsulation dot1q because this catalyst model is ISL capable also and the SF300 working only with Dot1q Encapsultion
    The configuration on catalyst should :
    #config terminal
    #interface Gi 1/0/45
    # switchport encapsulation 
    #switchport trunk encapsulation dot1q
    #switchport mode trunk 
    #switchport trunk allowed vlan 101-103
    #spanning-tree portfast
    For SF300 the port trunk it looks fine but for the port where the PC should receive an IP address
    #interface fastethernet29
     #switchport mode access
     #switchport ccess vlan 103
    Please let me know after this configuration
    Thanks
    Mehdi
    Please rate or mark as answered to help other Cisco Customers

  • Trunking between Huawei S3900 and Cisco catalyst 3750

    One of my edge Huawei S3700  switches  is dead, I am going to replace it with a Cisco switch Catalyst 3750 series PoE-48 via a trunk link  with GE fiber port on both ends, please see the diagram below.
                                      trunk                     trunk
       Core switchrouter<----------S3700<--------------->Cisco Catlyst 3750
    I haven’t touch Cisco switch for many years, I would like to ask the following questions:
    1.)      Do I need to take any precaution before connecting this Cisco switch into my Huawei network? Only one link between S3700 and C3750, so I don't need worry anout STP? Do I need to worry about Default vlan regarding trunking port?
    2.)      I need to use different trucking protocol e.g. 802.1Q etc to interconnect these two switches (S3700-28TP-SI-AC and Catalyst 3750), please see the following configuration:
    For C3750:
    switchport trunk encapsulation dot1q
    switchport trunk native vlan (What you want)
    switchport trunk allowed vlan (VLANs required)
    switchport mode trunk
    spanning-tree portfast trunk
    For S3700:
     port link-type trunk
     port trunk permit vlan all
    Do you think the configurations above are right?
    Do I need to manually enter Duplex and speed options ?       
    3.)If the configurations are not right, then what are the commands for trucking port/link should I use on the Cisco switch (it uses IOS software) and Huawei switch?  Procedures of the commands would be really helpful !
    Any information and help would be much appreciated.
    Thanks
    Regards

    Hello
     3750 - basic config
     ================
    See as you are using this switch as an host switch you need to make sure ip routing isn't enabled ( it isn't by default)
    Also it looks like the s3700 Huawei switch is permitting all vlans and I assuming the default native vlan is 1 ( as is cisco) so no need to specify the native either.
    If you are requiring the access ports on this new cisco 3750 to be in multiple vlans then usually cisco to cisco interconnect would ultise VTP for vlan propagation however this wont occur between the Huawei switch, so you will need to manually add the vlans on the switch also.
    so to summarize below is a basic host switch config for 3750.
    conf t
    no ip routing
    hostname XXXXXX
    username xxxx privilege 15 secret xxxxxxx
    service password-encryption
    enable secret xxxxx
    security passwords min-length xx
    security authentication failure rate xx log
    aaa new-model aaa authentication login default local
    logging buffered 4096
    no service udp-small-servers
    no service tcp-small-servers
    service timestamps debug datetime msec localtime
    service timestamps log datetime msec localtime
    no ip domain-lookup
    spanning-tree mode rapid-pvst
    spanning-tree portfast bpduguard default
    int vlan x ( this may or not be vlan 1 - its whatever the L3 vlan interface is on the core switch for management connectivity)
    ip address x.x.x.x y.y.y.y.
    exit
    ip default-gateway x.x.x.x ( ip address of CORE SVI management interface)
    vlan x,x,x,x ( add the L2 vlans to the switch as vtp would not be used between the Huawei switch)
    exit
    int gigx/x
    Description Link to Huawei switch
    switchport trunk encapsulation dot1q
    switchport mode trunk
    switchport nonegotiate
    no shut
    ( no need for spanning-tree portfast trunk- this is usually only for ESX host ports)
    int rang fa0/1 -48
    Description - Access-ports
    switchport host
    switchport access vlan x (wihout this defaults to vlan 1)
    no shut
    clock timezone gmt 0
    ntp peer
    ntp server x.x.x. prefer
    res
    Paul

  • Mini Displayport to Dual-Link DVI Issues on 30" Cinema Display

    I know this problem has been around for a while, and that there are several other discussion on it, but my goal here is to point out that even in mid-2011, this issue remains.
    Here's my configuration:
    30" Cinema Display
    Dual-link MDP to DVI adapter with 1.03 firmware (purchased August 2011 from an Apple Store)
    New-ish MacBook Pro (purchased December 2010) with Mini Displayport
    Symptoms:
    On dark areas of the screen, DVI noise appears (horizontal flickers of light coming and going at random)
    Attempted Fixes:
    Unplugging the display and plugging it back in to the computer (failed)
    Restarting the computer (failed)
    Tightening the connections on the Dual-Link DVI adapter (failed)
    Sleeping the display and awaking it (failed)
    Some suggest getting a new 27" Cinema Display with native Mini Displayport/Thunderbolt support. I actually have one, but I cannot tolerate the glare on the glossy displays, so I'm "downgrading" to a 30" Cinema Display.
    Is there any remaining hope for this issue?

    I still cannot understand why you would return everything... Ultimately you want this computer right? Once the bugs on the adapter are fixed are you gonna go back and re-buy it?
    Seems like a lot of time spent out of spite and not for good reason. Me, this is the best Mac I've ever owned (and I've owned many. no, really.) and I'm happy to wait for this adapter w/ this machine in stead of going back to my other box.
    I observed a similar client of mine w/ an iPhone... after the first week, he didn't like the keyboard and a few other things, so he took it back and went back to using his Blackberry -only to dump the Blackberry again for the iPhone, because he realized that the iPhone still did more things better than the Blackberry.
    J.

  • ACD 30" Dual Link DVI and MacBook Pro Unibody

    I have the following configuration:
    ACD 30" Dual Link DVI and MacBook Pro Unibody
    I am exhibiting some intermittent problems with the 30" display not coming up when I reboot for example and here are some more:
    1. MacBook Pro not in clam-shell mode and restart equals 30" display not turning on
    2. When in Snow Leopard and I have the MacBook Pro running in clam-shell mode and I open the display on the MacBook Pro it remains black.
    3. When waking the MacBook Pro from sleeping (MacBook Pro in clam-shell) the 30" ACD is "grainy" and the display is not usable and it requires a reboot to solve the problem.
    Any help? In addition are there any other displays using mini-display port to mini display port technology?
    What about a different monitor; will I still have to use the Dual Link DVI adapter to drive a display with higher than 1920x1200 resolution?
    Are there adapters to go from mini-display port to display port?
    Thanks,
    Mike

    Just came across your post and i have a couple of suggestions ive noticed with the Dual-Link to Mini-DP with the same configuration.
    When working in clamshell mode for example, the 30" will become the MAIN/Default display...So if you open your macbookpro while the 30" is on and the system is running, the screen will remain black because it is in closed mode; basically meaning there is no signal to be sent.
    so if you want the display to show up, either restart or put into sleep mode, then wake the system WITH THE LID OPEN.
    As for the grainy/static artifacts, its beena reported issue since day 1, not sure waht the fix or issue may be with it but heres a resolution.
    Press; SHIFT CONTROL EJECT-KEY all at once, this will disable signal to the monitor, but not shut off the machine...then use your mouse or press a key on the keyboard to wake the display and the grainyness should disappear.

  • Password problem on Catalyst 3750

    Hi all,
    I am an Unix administrator and we lost all account and password informations to connect on a Catalyst 3750 switch.
    Is there a way to connect to the switch (With a serial cable?) an to create a new account without losing the configuration ?
    Thank's for your reply.
    Regards.

    This method won't reset the configuration.
    During the boot process, you rename the current configuration so it doesn't get loaded.
    rename flash:config.text flash:config.old
    When  the switch boots, it loads a blank image. Then you rename the config  file and load it into the running config and you can change the logon  credentials to something you know.
    It's important that you follow the steps exactly so you don't lose the configuration. Password recovery is a pretty common procedure.
    The  only other method of recovery is if you have a copy of the current  running configuration. Send me a private message if you have this config and we can discuss the possibility.

  • Catalyst (3750 24 10/100/1000T) and (3750 12 SFP) Stacking Problems

    Dear all
    I'm having a very strange situation here (at least for me)
    we have 4 core switches
    2 x   WS-C3750G-24T-S Catalyst 3750 24 10/100/1000T + IPB Image
    and
    2 x   WS-C3750G-12S-S Catalyst 3750 12 SFP + IPB Image
    Stack configuration is done this way
    when the switches are powered on, the first two SFP core switches are seen as a single stack with the stack master LED turned green on the first switch
    the other two (24 10/100/1000T) switches have the RPS LEDs always green, mode cannot be changed, and cannot be accessed by Console connection
    but when the (24 10/100/1000T) are powered off, the first (SFP) switch in the stack reports that " Switch 3 and 4 has been removed from Stack "
    which means they are stacked but there's something wrong, because
    only the SFP ports are shown in the " Show interfaces status " , the ethernet ports of the bottom switches are not present !!!
    can you please tell me what's the poblem ?

    Dear Daniel
    Sorry for my delayed response but i was actually quite busy
    but the problem was actually in another sense
    the default profile for the Catalyst 3750 SFP is the Aggregate SDM Template
    while the 3750 10/100/1000 ethernet Switch Default SDM profile was Desktop profile
    so i had an SDM mismatch
    DATACENTER#sh switch detail
    Switch/Stack Mac Address : 081f.f3cf.1c80
                                               H/W   Current
    Switch#  Role   Mac Address     Priority Version  State
    *1       Master 081f.f3cf.1c80     1      0       Ready              
    2       Member 081f.f3cf.5900     1      0       Ready              
    3       Member aca0.16ac.0180     1      2       SDM Mismatch       
    4       Member aca0.16a3.bc80     1      2       SDM Mismatch 
             Stack Port Status             Neighbors    
    Switch#  Port 1     Port 2           Port 1   Port 2
      1        Ok         Ok                2        4
      2        Ok         Ok                3        1
      3        Ok         Ok                4        2
      4        Ok         Ok                1        3 
    all i did was changing the default profile of the SFP switches into the Desktop Profile and problem was solved
    switch 1 provision ws-c3750g-12s
    switch 2 provision ws-c3750g-12s
    switch 3 provision ws-c3750g-24t
    switch 4 provision ws-c3750g-24t
    system mtu routing 1500
    ip subnet-zero
    no file verify auto
    spanning-tree mode pvst
    spanning-tree extend system-id
    vlan internal allocation policy ascending
    interface GigabitEthernet1/0/1
    interface GigabitEthernet1/0/2
    interface GigabitEthernet1/0/3
    interface GigabitEthernet1/0/4
    interface GigabitEthernet1/0/5
    interface GigabitEthernet1/0/6
    interface GigabitEthernet1/0/7
    interface GigabitEthernet1/0/8
    interface GigabitEthernet1/0/9
    interface GigabitEthernet1/0/10
    interface GigabitEthernet1/0/11
    interface GigabitEthernet1/0/12
    interface GigabitEthernet2/0/1
    interface GigabitEthernet2/0/2
    interface GigabitEthernet2/0/3
    switchport trunk encapsulation dot1q
    switchport mode trunk
    interface GigabitEthernet2/0/4
    interface GigabitEthernet2/0/5
    interface GigabitEthernet2/0/6
    interface GigabitEthernet2/0/7
    interface GigabitEthernet2/0/8
    interface GigabitEthernet2/0/9
    interface GigabitEthernet2/0/10
    interface GigabitEthernet2/0/11
    interface GigabitEthernet2/0/12
    interface GigabitEthernet3/0/1
    interface GigabitEthernet3/0/2
    interface GigabitEthernet3/0/3
    interface GigabitEthernet3/0/4
    interface GigabitEthernet3/0/5
    interface GigabitEthernet3/0/6
    interface GigabitEthernet3/0/7
    interface GigabitEthernet3/0/8
    interface GigabitEthernet3/0/9
    interface GigabitEthernet3/0/10
    interface GigabitEthernet3/0/11
    interface GigabitEthernet3/0/12
    interface GigabitEthernet3/0/13
    interface GigabitEthernet3/0/14
    interface GigabitEthernet3/0/15
    interface GigabitEthernet3/0/16
    interface GigabitEthernet3/0/17
    interface GigabitEthernet3/0/18
    interface GigabitEthernet3/0/19
    interface GigabitEthernet3/0/20
    interface GigabitEthernet3/0/21
    interface GigabitEthernet3/0/22
    interface GigabitEthernet3/0/23
    interface GigabitEthernet3/0/24
    interface GigabitEthernet4/0/1
    interface GigabitEthernet4/0/2
    interface GigabitEthernet4/0/3
    interface GigabitEthernet4/0/4
    interface GigabitEthernet4/0/5
    interface GigabitEthernet4/0/6
    interface GigabitEthernet4/0/7
    interface GigabitEthernet4/0/8
    interface GigabitEthernet4/0/9
    interface GigabitEthernet4/0/10
    interface GigabitEthernet4/0/11
    interface GigabitEthernet4/0/12
    interface GigabitEthernet4/0/13
    interface GigabitEthernet4/0/14
    interface GigabitEthernet4/0/15
    interface GigabitEthernet4/0/16
    interface GigabitEthernet4/0/17
    interface GigabitEthernet4/0/18
    interface GigabitEthernet4/0/19
    interface GigabitEthernet4/0/20
    interface GigabitEthernet4/0/21
    interface GigabitEthernet4/0/22
    interface GigabitEthernet4/0/23
    interface GigabitEthernet4/0/24
    that's it !
    : D
    cheers

  • Policer with IPv6 class-map on Catalyst 3750

    Hi,
    I've the following problem.
    It's my goal to ratelimit incoming IPv6 traffic dependent on the destination IP address range.
    On a Catalyst 3750 (Image: c3750-ipservicesk9-mz.122-55.SE1.bin) I've set up the configuration as follows:
    mls qos
    ipv6 access-list DESTINATION-RANGE-A
     permit ipv6 any 2007::/16
    ipv6 access-list DESTINATION-RANGE-B
     permit ipv6 any 2B03::/16
    class-map match-all A
     match access-group name DESTINATION-RANGE-A
    class-map match-all B
     match access-group name DESTINATION-RANGE-B
    policy-map RL-POLICY
     class A
      police 2000000 8000 exceed-action drop
     class B
      police 6000000 8000 exceed-action drop
    interface GigabitEthernet1/0/7
     switchport access vlan 90
     load-interval 30
     service-policy input RL-POLICY
    The last CLI command which should bind the policy to the specific interface, leads to the following error message
    QoS: class(A) IPv6 class not supported on interface GigabitEthernet1/0/7
    Are hardware/software limitations the reason for this behavior or is there any misconfiguration?
    Thanks in advance for your help!
    Regards,
    Jens

    If you are thinking of IPv6 prefix I tried everything. From /128 for single host to /64, nothing works.

  • Ratelimiter with IPv6 class-map on Catalyst 3750

    Hi,
    I've the following problem.
    It's my goal to ratelimit incoming IPv6 traffic dependent on the destination IP address range.
    On a Catalyst 3750 (Image: c3750-ipservicesk9-mz.122-55.SE1.bin) I've set up the configuration as follows:
    mls qos
    ipv6 access-list DESTINATION-RANGE-A
     permit ipv6 any 2007::/16
    ipv6 access-list DESTINATION-RANGE-B
     permit ipv6 any 2B03::/16
    class-map match-all A
     match access-group name DESTINATION-RANGE-A
    class-map match-all B
     match access-group name DESTINATION-RANGE-B
    policy-map RL-POLICY
     class A
      police 2000000 8000 exceed-action drop
     class B
      police 6000000 8000 exceed-action drop
    interface GigabitEthernet1/0/7
     switchport access vlan 90
     load-interval 30
     service-policy input RL-POLICY
    The last CLI command which should bind the policy to the specific interface, leads to the following error message
    QoS: class(A) IPv6 class not supported on interface GigabitEthernet1/0/7
    Are hardware/software limitations the reason for this behavior or is there any misconfiguration?
    Thanks in advance for your help!
    Regards,
    Jens

    If you are thinking of IPv6 prefix I tried everything. From /128 for single host to /64, nothing works.

  • Debian Linux Bonding and Cisco Catalyst 3750 - best practise?

    Hello everybody,
    I would like to know what's best practice to do this:
    The two NICs of a Debian Linux server wants to be connected with two Switchports of a Cisco Catalyst 3750 switch(stack). My goal is to have load-balancing and failover.
    My /etc/network/interfaces looks like this:
    iface bond0 inet static
           address 192.168.0.30
           netmask 255.255.255.0
           network 192.168.0.0
           broadcast 192.168.0.255
           gateway 192.168.0.1
           dns-nameservers 192.168.0.10 192.168.0.20
           dns-search xyz.mycompany.com
           slaves eth0 eth1
           bond_mode ???
           bond_miimon 100
           bond_downdelay 200
           bond-updelay 200
    First question: What bond mode should I use?
    The switchports looks like this:
    interface GigabitEthernet3/0/4
     switchport access vlan 20
     switchport mode access
     spanning-tree portfast
    What changes are necessery here? Something like this?
    interface GigabitEthernet3/0/4
     switchport trunk encapsulation dot1q
     switchport mode trunk
     spanning-tree portfast
    Thanks a lot for suggestions, hints, etc.! :-)
    Greets
    Stephan

    Hi Michael,
    thanks a lot for your answer - and sorry for my late reply!
    I like to show you my solution - I hope that it is a solution. ;-)
    My config on the switch(stack):
    switch#show etherchannel summary
    Group  Port-channel  Protocol    Ports
    ------+-------------+-----------+-----------------------------------------------
    2      Po2(SU)         LACP      Gi3/0/3(P)  Gi4/0/3(P)
    switch#show running-config interface GigabitEthernet 3/0/3
    Building configuration...
    Current configuration : 172 bytes
    interface GigabitEthernet3/0/3
     description myserver, eth0
     switchport access vlan 20
     switchport mode access
     channel-group 2 mode active
     spanning-tree portfast
    end
    lansw01#show running-config interface GigabitEthernet 4/0/3
    Building configuration...
    Current configuration : 172 bytes
    interface GigabitEthernet4/0/3
     description myserver, eth1
     switchport access vlan 20
     switchport mode access
     channel-group 2 mode active
     spanning-tree portfast
    end
    switch#show running-config interface port-channel 2
    Building configuration...
    Current configuration : 82 bytes
    interface Port-channel2
     switchport access vlan 20
     switchport mode access
    end
    The /etc/network/interfaces of my Debian machine looks like this:
    auto lo
    iface lo inet loopback
    auto bond0
            iface bond0 inet static
            address 192.168.1.xxx
            netmask 255.255.255.0
            gateway 192.168.1.xxx
            dns-nameservers 192.168.1.xxx
            dns-search xxx.xxx.xxx
            bond-mode 4
            bond-miimon 100
            bond-downdelay 200
            bond-updelay 200
            bond-lacp-rate 1
            slaves eth0 eth1
    This setup seems to work well. But I'm wondering that there is nothing with "trunking" in my setup. Would you like to give me your opinion about this?
    Thanks a lot and many greets
    Stephan

Maybe you are looking for

  • Update data automatically in fact table in Data Warehouse

    Hi, I'm working on the creation of a data warehouse that include different data source like SQL Server performance (more than one), Active Directory users, Server performance (more than one), Exchange server mailboxes. The problem is that performance

  • How to Design Multi Page Report in SSRS 2008

    Hi All, I have managed to create a multi page report. When I am preview mode i can see that the report has 2 pages. But when I am in design view I cannot view the second page. How can I view the second page. Reason being I am trying to create a templ

  • Installing iTunes 7.5 error

    Each time I try to install iTunes for Windows I get this eror Unable to install iTunes could not open key Hkeylocalmachine\software\microsoft\windows\currentversion\shareddlls. I have un-installed iTunes an Quicktimes deleted it from the registry and

  • Why has Mountain Lion created 3 iMessage accounts on download

    Does anyone have any idea why Messages is not working since I downloaded Mountain Lion. I was using a Beta version on Lion with no problem. Since I have downloaded Mountain Lion, three iMessage Accounts have appeared in my Accounts panel, along with

  • Signiature problem when instaling new update

    I went to update the neweat sofware for itunes in which i selected it and downloaded it and then it suddenly stopped, bringing up a sign saying there is something wrong with my signiature and then i click ok and another sign comes up saying try to re