Configuring new 4506 switches.

MERRY X-MAS !!!
I am going to configure IOS version of brand new 4506 Switch with Supervisory engine IV. You guys know that it has separate modules of Supervisory engine, 3 to 4 blades, redundant power supply. Because of this little bit confused. Apart from doing VLAN, STP configs, should I need to do any other configs for the chassis, redundant power supplies, blades, memory ect…..
If u do have any sample configs plz do help me guys…

No configuration needed for chassis/RPS. Configuration guidelines should help
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat4000/12_2_25a/index.htm

Similar Messages

  • Attaching a new 4506-E switch to 2 N7K's using vPC?

    Hi,
    I need to connect a new 4506-E switch to my existing two N7K switches using port-channels and vPC. Will there be any traffic disruptions when assigning the vPC id to the port-channel?
    Thanks,
    Pradeep

    Hi,
    there should not be any traffic interruption on the 7ks, since the is a new vPC only for the 4506.
    HTH

  • MAC Addressess not showing on my new 3560 switch

    I have a Cisco 3560 (Switch B) switch I just introduced into my network.  The gigabit ports are trunked from another switch (Switch A) to a Cisco 6509 WS (Main Switch).
    crpf4bsw3#show cdp neighbors
    Device ID            Local Intrfce         Holdtme   Capability    Platform   Port ID
    crpf4bsw2.mdch.com
                        Gig 0/1               124            S I      WS-C3560-4Gig 0/4
    crpcorsw1.mdch.com
                        Gig 0/4               127           R S I     WS-C6509-EGig 2/8
    interface GigabitEthernet0/4
     switchport trunk encapsulation dot1q
     switchport trunk allowed vlan 1,19,124,150,160,164,168,224
     switchport mode trunk
     mls qos trust dscp
     spanning-tree link-type point-to-point
    interface GigabitEthernet0/1
     switchport trunk encapsulation dot1q
     switchport trunk allowed vlan 1,19,124,150,160,164,168,224
     switchport mode trunk
     mls qos trust dscp
     spanning-tree link-type point-to-point
    The trunk ports are working just fine.  I have configured all necessary remote management with no issues.  However, my access ports are not working.  I have set them up exactly the same as the adjacent switch A and it works just fine, but the same configuration on the new switch has not been able to pull IP information.  I have provided information as to how the switch access ports are configured on both Switch A (working) and Switch B (not working).  I should note that I tried this with a Cisco 7940 phone and it got stuck on "configuring IP" then I tried it with my laptop and it pulled a 169 IP address.  Both were direct connections into switch B.  When I run a show mac-address-table, neither device shows up in the table.  Only the gig port MACs.  Any thoughts? Please let me know if you need any more information.
    interface FastEthernet0/3
     switchport access vlan 124
     switchport mode access
     switchport voice vlan 224
     switchport port-security maximum 3
     switchport port-security
     switchport port-security aging time 2
     switchport port-security violation restrict
     switchport port-security aging type inactivity
     srr-queue bandwidth share 10 10 60 20
     srr-queue bandwidth shape  10  0  0  0
     mls qos trust device cisco-phone
     mls qos trust cos
     auto qos voip cisco-phone
     spanning-tree portfast
     spanning-tree bpduguard enable

    Hi Mike,
    It looks like you're guiding me in the right direction.  I did a "show port security interface fa0/2" on the new switch and nothing was out of the ordinary with the exception of the 0 MAC addresses learned.  But then I did a "show spanning tree vlan 224" Here's what I found:
    Switch A (existing switch):
    crpf4bsw2#show spanning-tree vlan 224
    VLAN0224
      Spanning tree enabled protocol rstp
      Root ID    Priority    4096
                 Address     0012.44cc.68e0
                 Cost        8
                 Port        1 (GigabitEthernet0/1)
                 Hello Time   2 sec  Max Age 20 sec  Forward Delay 15 sec
      Bridge ID  Priority    32992  (priority 32768 sys-id-ext 224)
                 Address     0013.60aa.7400
                 Hello Time   2 sec  Max Age 20 sec  Forward Delay 15 sec
                 Aging Time 300
    Interface        Role Sts Cost      Prio.Nbr Type
    Gi0/1            Root FWD 4         128.1    P2p
    Fa0/1            Desg FWD 19        128.3    Edge P2p
    Fa0/2            Desg FWD 19        128.4    Edge P2p
    Fa0/3            Desg FWD 19        128.5    Edge P2p
    Fa0/4            Desg FWD 19        128.6    Edge P2p
    Fa0/5            Desg FWD 19        128.7    Edge P2p
    Fa0/6            Desg FWD 19        128.8    P2p Peer(STP)
    Interface        Role Sts Cost      Prio.Nbr Type
    Fa0/7            Desg FWD 19        128.9    Edge P2p
    Fa0/8            Desg FWD 19        128.10   Edge P2p
    Fa0/9            Desg FWD 19        128.11   Edge P2p
    Fa0/10           Desg FWD 19        128.12   Edge P2p
    Fa0/11           Desg FWD 19        128.13   Edge P2p
    Fa0/12           Desg FWD 19        128.14   Edge P2p
    Fa0/13           Desg FWD 19        128.15   Edge P2p
    Fa0/15           Desg FWD 19        128.17   Edge P2p
    Fa0/19           Desg FWD 19        128.21   Edge P2p
    Fa0/20           Desg FWD 19        128.22   Edge P2p
    Gi0/4            Desg FWD 4         128.28   P2p
    Fa0/29           Desg FWD 19        128.33   Edge P2p
    Fa0/30           Desg FWD 19        128.34   Edge P2p
    Fa0/31           Desg FWD 19        128.35   Edge P2p
    Fa0/32           Desg FWD 19        128.36   Edge P2p
    Fa0/33           Desg FWD 19        128.37   Edge P2p
    Fa0/34           Desg FWD 19        128.38   Edge P2p
    Fa0/35           Desg FWD 19        128.39   Edge P2p
    Fa0/37           Desg FWD 19        128.41   Edge P2p
    Fa0/38           Desg FWD 19        128.42   Edge P2p
    Fa0/39           Desg FWD 19        128.43   Edge P2p
    Fa0/40           Desg FWD 19        128.44   Edge P2p
    Fa0/41           Desg FWD 19        128.45   Edge P2p
    Interface        Role Sts Cost      Prio.Nbr Type
    Fa0/42           Desg FWD 19        128.46   Edge P2p
    Fa0/43           Desg FWD 19        128.47   Edge P2p
    Fa0/44           Desg FWD 19        128.48   Edge P2p
    Fa0/45           Desg FWD 19        128.49   Edge P2p
    Fa0/46           Desg FWD 19        128.50   Edge P2p
    Switch B (new switch):
    Spanning tree instance(s) for vlan 224 does not exist.
    So with this new information, and with my trunk configurations above, what did you mean by a disconnect on the trunk?

  • Best way to remove CSM configuration from a switch

    have a redundant pair of CSM , would like to move slave CSM to a new switch, what is quickest way to eliminate all configuration from this switch so the same can be installed on the new switch , without reloading the switch or causing any downtime to already existing connections through the master CSM.

    HI Imre,
    Kindly read the following section for the required :
    http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/csm/4.2.x/configuration/guide/redun.html#wp1047388

  • WCCP ACL on 4506 switch

    Hi ,
    We have a cisco 4506 switch with the IOS version of 12.2-50.SG1. I would like to know whether any latest IOS version will support redirect ACL with the deny statement for WCCP on a client interface.
    Switch details:
    cisco WS-C4506-E (MPC8245) processor (revision 7) with 524288K bytes of memory.
    Processor board ID FOX1407G5P7
    MPC8245 CPU at 333Mhz, Supervisor IV
    Last reset from Reload
    5 Virtual Ethernet interfaces
    192 FastEthernet interfaces
    26 Gigabit Ethernet interfaces
    403K bytes of non-volatile configuration memory.
    Regards,
    Bala

    Hey CJ,
    Option 1: another option you might consider is intercepting closer to the WAN edge, if that's an available option for you.
    Again, like Patrick mentioned it depends on your network / IP design but if you intercept closer to the WAN edge you should be able to avoid engineering a redirect ACL altogether.
    Option 2: depending on the 3750 platform and code upgrade options, some of the latest 3750 IOS versions include support for deny entries for WCCP redirect ACLs. Check out these release notes (look at the very last bullet point in this list):
    http://www.cisco.com/en/US/docs/switches/lan/catalyst3750x_3560x/software/release/12.2_58_se/release/notes/OL24338.html#wp1009434
    Hope this helps!
    -Chet

  • Cisco 4506 Switch Hanging

    I have got a 4506 switch with Sup V 10GE. This switch is in VTP domain, but in VTP transparent mode. I has got hanged twice, could anybody tell me the reason what could have happend.
    There was no configuration change been done to that switch.

    Hi Suresh,
    CSCsb61172 can be confirmed by looking at the output of "show platform hardware interface all".
    eg:
    CAT4510#show platform hardware interface all
    Global Hardware Gigaport State
    RxIpg : 6
    TxIpg : 264
    FreeListCount : 329 <<<-----
    Note that typical values of the free list count are between 20,000 and 64,000 depending on the traffic
    being switched. A count of 329 above is too low and indicates a memory leak.
    So if you see the number decreasing constantly, then you are running into this issue. The fix is in 12.2(25)EWA5, 12.2(31)SG, and higher.
    HTH,
    Bobby
    *Please rate helpful posts.

  • Error while configure new plant

    Dear Friends,
            I have  configured new plant - 8888 in company - 1000, and while creating a sale order for that plant,  i am getting the below mentioned error msg, guide me to solve this....
    " No add. company data maint. for 1000 8888 - please maintain J_1IMOCOMP ".
    Thanks & Regards
    T.Arulvanan.

    Hi,
    Please chech whether you have assogned the plant to the distribution chain(i.e. the sales org+ dist.channel). Only then the plant becomes a delivering plant and allows you to create sales orders.
    Regards,
    Raghav

  • How we can configure new pricing procedure at the time of billing document

    Hi SD Gurus,
    Can u plz tell me how we can configure new pricing procedure at the time of billing document level.
    Thanks & Regards,
    Sreenivas.P

    Hello,
    Why?
    The sales order confirms the price given to the customer.  If you have re-determined a new price/discount then you may consider in VTFL to use pricing type C.
    Regards
    Waza

  • Configuration - New G/L

    Hi people,
    Could you tell pass by pass about the configuration New G/L?
    Or give me the best link where there are that?
    Thanks a lot,
    Rosana.

    Hi
    Refer the link
    http://help.sap.com/saphelp_erp60_sp/helpdata/en/2d/830e405c538f5ce10000000a155106/frameset.htm
    It will give you a general idea on how New GL is configured
    Regards
    Sanil Bhandari

  • "When I open a link in a new tab, switch.." Doesnt work correctly

    I'm using Firefox 28.0 (Waterfox build)
    I've verified that:
    - browser.tabs.loadInBackground: False
    - browser.tabs.loadDivertedInBackground: True
    - "When I open a link in a new tab, switch to it immediately" is enabled in the UI.
    It seems only some websites actually switch to the new tab. Also, sometimes, this feature will stop working all together; requiring me to toggle the Firefox UI setting and/or restart firefox.

    Start Firefox in <u>[[Safe Mode|Safe Mode]]</u> to check if one of the extensions (Firefox/Tools > Add-ons > Extensions) or if hardware acceleration is causing the problem.
    *Switch to the DEFAULT theme: Firefox/Tools > Add-ons > Appearance
    *Do NOT click the Reset button on the Safe Mode start window
    *https://support.mozilla.org/kb/Safe+Mode
    *https://support.mozilla.org/kb/Troubleshooting+extensions+and+themes

  • How to configure new account assignment group of material

    dear expert
    how to configure new account assignmnet group of material
    vicky

    how to configure new account assignmnet group of material
    Probably, the question should have been how to create Account Assignment Group for a material.
    Go to IMG SD => Basic Functions => Account Assignment/Costing => Revenue Account Determination => Check Master Data Relevant for Account Asignment.
    There select Materials : Account Assignment Groups and create as per the requirement and save.  Now you can see the same while creating the material master.
    thanks
    G. Lakshmipathi

  • The "when I open a new link in a new tab, switch to it immediately" check box is not checked but it acts as if I check the check box

    The "when I open a new link in a new tab, switch to it immediately" check box is not checked but it acts as if I have checked the check box.
    == This happened ==
    Every time Firefox opened
    == after I install the Persona themes

    I was having the same problem and was looking for solutions when I came across this posting. Disabling GoodSearch solved the problem for me. Hopefully GoodSearch will update soon and resolve the issue permanently so I can use it again.

  • WAAS Configuration for 3750 Switch

    I am configuring a 3750 switch with 12.2(52)SE according to:
    (from https://www.cisco.com/en/US/docs/switches/lan/catalyst3750/software/release/12.2_52_se/configuration/guide/3750_scg.pdf )
    This example shows how to configure SVIs and how to enable the web cache service with a multicast group list. VLAN 299 is created and configured with an IP address of 175.20.20.10. Gigabit Ethernet port 1 is connected through the Internet to the web server and is configured as an access port in VLAN 299. VLAN 300 is created and configured with an IP address of 172.20.10.30. Gigabit Ethernet port 2 is connected to the application engine and is configured as an access port in VLAN 300. VLAN 301 is created and configured with an IP address of 175.20.30.50. Fast Ethernet ports 3 to 6, which are connected to the clients, are configured as access ports in VLAN 301. The switch redirects packets received from the client interfaces to the application engine.
    Note Only permit ACL entries are being used in the redirect-list; deny entries are unsupported.
    Switch# configure terminal
    Switch(config)# ip wccp web-cache 80 group-list 15
    Switch(config)# access-list 15 permit host 171.69.198.102
    Switch(config)# access-list 15 permit host 171.69.198.104
    Switch(config)# access-list 15 permit host 171.69.198.106
    Switch(config)# vlan 299      WEB  SERVER
    Switch(config-vlan)# exit
    Switch(config)# interface vlan 299
    Switch(config-if)# ip address 175.20.20.10 255.255.255.0
    Switch(config-if)# exit
    Switch(config)# interface gigabitethernet1/0/1
    Switch(config-if)# switchport mode access
    Switch(config-if)# switchport access vlan 299
    Switch(config)# vlan 300 WAE
    Switch(config-vlan)# exit
    Switch(config)# interface vlan 300
    Switch(config-if)# ip address 171.69.198.100 255.255.255.0
    Switch(config-if)# exit
    Switch(config)# interface gigabitethernet1/0/2
    Switch(config-if)# switchport mode access
    Switch(config-if)# switchport access vlan 300
    Switch(config-if)# exit
    Switch(config)# vlan 301 CLIENTS
    Switch(config-vlan)# exit
    Switch(config)# interface vlan 301
    Switch(config-if)# ip address 175.20.30.20 255.255.255.0
    Switch(config-if)# ip wccp web-cache redirect in
    Switch(config-if)# exit
    Switch(config)# interface gigabitethernet1/0/3 - 6
    Switch(config-if-range)# switchport mode access
    Switch(config-if-range)# switchport access vlan 301
    Switch(config-if-range)# exit
    ===================================================================
    Question:  How do I configure my WAE to play nicely with this switch?

    Hi James,
    Here is the link to WCCP config part on WAE:
    http://www.cisco.com/en/US/docs/app_ntwk_services/waas/waas/v441/configuration/guide/traffic.html#wp1041742
    In your case, if my understanding is right, VLAN300 is where you want to connect WAE and WAE is also L2 adjacent. if that is true, here is the config you need on WAE:
    wccp router-list 1 171.69.198.100
    wccp tcp-promiscuous router-list-num 1 l2-redirect mask-assign l2-return
    wccp version 2
    Please note that 3750 supports L2 redirection only with redirect IN statements on 3750 interfaces connected to servers and clients.
    Hope this helps.
    Regards.

  • Server wont communicate with new network switch.

    Hi, I hope someone can help.
    I have a small office network running Macs with OS 10.6.4, HPs with Windows XP, and a mac mini server running 10.6.4 server, file sharing only.
    DHCP and internet access etc is controlled by a Netgear ADSL router. All machines are connected by a 16 port 10/100 Netgear switch.
    The problem is I replaced the switch with a 10/100/1000 switch and all machines connect fine except the server. This will not connect at all with the new switch, not even do any lights come on. However if I connect the server to the old 10/100 switch then to the new gigabit switch it connects fine but this defeats the purpose of the gigabit access to the server and the high speed macs on the network. The reason I upgraded in the first place! The standard Macs are Imac G5 Intel based late Snow leopard models and they have no trouble with the new switch.
    Does Snow Leopard server somehow remember specific hardware on the network when setup? And needs to be changed to recognize the new?? I tried switching everything off and restarting the whole network.
    I don't have a heap of knowledge but thought this should have been simple.
    Any help would be greatly appreciated.
    Cheers, paul

    Thanks for the reply.
    No it is not managed, No uplink port, uplink is auto controlled on any port.
    I have swapped and swapped and swapped this is what led me to using the old switch on the server.
    This is what happens.
    Putting the server cable from the server into the new gigabit switch Tried with 300m cable directly next to it. No connection on any of the 16 ports. tried several cables including longer ones etc.
    Now if I use the same cable from the gigabit switch to any port on the old switch then connect a cable from any other port of the old switch to the server. Connection, no problems at all. I.E the Old switch is uplinking to the new.
    It is as if the server says "hey where is the old switch I can't work without it" Thats why I thought maybe OS X server kept some sort of register of the devices when it is initially setup and this may need to be changed.
    Also any other computer works fine when placed at the same access point as the server including the Standard Snow leopard Macs.
    I am thinking maybe to reinstall the server OS to see what happens?
    Was supposed to be a simple job. Both switches are physically exactly the same. Pull a cable out of port 1 and stick it in port 1 of the new switch etc plug it in and turn it on????

  • Configure new Volume unit

    Dear all, pls suggest me how to configure new volume unit in Material master Basic data !...

    Hi,
    You can create your own Unit of measure in t.code: CUNI & then enter in material master during creation of material in MM01.
    More check link:
    http://wiki.sdn.sap.com/wiki/display/SI/UnitofMeasurerelatedsettingsinSAP
    Regards,
    Biju K