Connect CS 6248 FI to N5K-C5548UP

How do i connect UCS 6248 Fabric Interconnect to N5K-C5548UP? do i need to use FCoE or vPC as i will have multiple SAN connected (using FC) on FI.
Please suggest best possible solution where i have minimul cabling hedache & can optimise physicl ports on N5K.

Mahesh,
Have you read through the UCS Deployment Guide?  I would suggest starting there.  After you're familiar with the options we can discuss/recommend further.
http://www.cisco.com/en/US/docs/solutions/Enterprise/Borderless_Networks/Smart_Business_Architecture/February2012/SBA_Mid_DC_UnifiedComputingSystemDeploymentGuide-February2012.pdf
Regards,
Robert

Similar Messages

  • Connecting UCS 6248 FI to N5K-C5548UP

    hi,
    How do i connect UCS 6248 Fabric Interconnect to N5K-C5548UP? do i need to use FCoE or vPC as i will have multiple SAN connected (using FC) on FI.
    Please suggest best possible solution where i have minimul cabling hedache & can optimise physicl ports on N5K.
    Regards
    Mahesh

    Hi Mahesh,
    vPC for FCoE uplink and / or unified uplinks is not supported at this time.
    vPC only for pure ethernet uplinks still works the same way.
    ./Abhinav

  • Please tell me how to connect with FCoE UCS-mini and Nexus N5k (N5K-C5548UP-B-S32)

    I have UCS 5108 Blade Server Chassis (with two B200 M3 Blade Servers inside and two FI 6324) connected to Nexus N5k switch through 4x10GE links.
    I want to configure the two aggregated channels FCoE (vFC) from chassi to switch.
    All instructions I've been seen refer to the fact that UCS-mini must be in the FC end-host mode, but UCSM 3.0 version does not support this mode, what shoud I do?
    I set up following the instructions www.cisco.com/c/en/us/support/docs/switches/nexus-5000-series-switches/116248-configure-fcoe-00.html
    But, after setup I have a fault on fabric: FCoE or FC uplink is down on Vsan 500;
    And in Nexus: Vsan 500 is down (waiting for flogi)
    When I do "show interface vfc 1" from Nexus CLI I see no 'Trunk vsans (up)', but
    'Trunk vsans (initializing)             (500)'
    Unfortunately, I can't find technical notes for UCS mini (with UCSM v. 3.0), so may be You can promt any guides or suggestion for this?
    Thank You in advance!

    The release notes of 3.0.1e, which is for UCS-mini,
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/release/notes/ucs_3_0_rn.html
    says:
    Unsupported Features
    The following features are not supported in Cisco UCS Manager, Release 3.0:
    Features, defect fixes, and platforms introduced in Cisco UCS Manager, Release 2.2(2c) and newer that are not explicitly called out in New Features or Resolved Caveats sections of this document.
    Some features introduced in Cisco UCS Manager, Release 2.2(1b) and earlier releases:
    –Ethernet Switching Mode
    –FC End Host Mode
    – Private VLANs
    – Port Security
    – KVM Virtualization is not tested (although not explicitly disabled)

  • Nexus N5K-C5548UP UDLD troubles

    I haven't been able bringing up links between N7k and and the new N5K (5548UP)  due to errors with UDLD.
    Someone else facing same problem ?
    regards
    Edmund
    N5K:
    Software
      BIOS:      version 3.5.0
      loader:    version N/A
      kickstart: version 5.1(3)N2(1a)
      system:    version 5.1(3)N2(1a)
    N7K:
    Software
      BIOS:      version 3.22.0
      kickstart: version 5.1(4)
      system:    version 5.1(4)
    Logs at N7K:
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-SPEED: Interface Ethernet1/2, operational speed changed to 10 Gbps
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/2, operational duplex mode changed to Full
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/2, operational Receive Flow Control state cha
    nged to off
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/2, operational Transmit Flow Control state ch
    anged to off
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-SPEED: Interface port-channel14, operational speed changed to 10 Gbps
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-IF_DUPLEX: Interface port-channel14, operational duplex mode changed to Full
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface port-channel14, operational Receive Flow Control state
    changed to off
    2012 Jun 15 14:46:58 swi-svi00A %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface port-channel14, operational Transmit Flow Control state
    changed to off
    2012 Jun 15 14:47:05 swi-svi00A %UDLD-4-UDLD_PORT_DISABLED: UDLD disabled interface Ethernet1/2, empty echo detected
    2012 Jun 15 14:47:16 swi-svi00A %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: Ethernet1/2: Ethernet1/2 is suspended
    2012 Jun 15 14:47:16 swi-svi00A %ETHPORT-5-IF_TRUNK_UP: Interface Ethernet1/2, vlan 1,60,100,358,370,380,500-501,505,700-703,710
    -713,720-723,730-735,759-762,764-765,767,770,775-778,782-783,787-788,794-796 up
    2012 Jun 15 14:47:16 swi-svi00A %ETHPORT-5-IF_TRUNK_UP: Interface Ethernet1/2, vlan 999-1000,1501,2029-2030 up
    2012 Jun 15 14:47:16 swi-svi00A %ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface Ethernet1/2 is down (Error disabled. Reason:UDLD em
    pty echo)
    2012 Jun 15 14:52:16 swi-svi00A %ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface Ethernet1/2 is down (Error disabled. Reason:UDLD em
    pty echo)
    ==
    swi-svi00A# sh udld ethernet 1/2
    Interface Ethernet1/2
    Port enable administrative configuration setting: enabled-aggressive
    Port enable operational state: enabled-aggressive
    Current bidirectional state: unknown
    Current operational state:  disable-port - Multiple neighbor not detected
    Message interval: 7
    Timeout interval: 5
            Last pkt send on: 719482, Jun 15 14:47:05 2012
                    Probe pkt send on: 401784, Jun 15 14:46:59 2012
                    Echo  pkt send on: 461880, Jun 15 14:47:05 2012
                    Flush pkt send on: 719482, Jun 15 14:47:05 2012
            Last pkt recv on: 719134, Jun 15 14:47:05 2012
                    Probe pkt recv on: 719134, Jun 15 14:47:05 2012
                    Echo  pkt recv on: None.
                    Flush pkt recv on: None.
            Deep pkt inspections done: None.
            Mismatched if index found: None.
            Deep pkt inspection drops: None.
    (Member of port-channel14)

    You are probably running into bug-id CSCtz00790. (see below)
    I had the same issue with UDLD no echo reply over SFP+ cables. The bug is Fixed-In 5.1(3)N2(1a)
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCtz00790

  • Connecting N5K and Brocade CNA 1860

    Tried 1, 3 and 7 m Cisco twinax cables, but Brocade is always reporting unsupported SFP. What should be used? Is there any twinax vendor that's is supported by both?
    Thanks.

    yeah, I found that link to and this part is disturbing:
    "If you want to connect a Brocade CNA to a Cisco ToR switch (Nexus), you could use the EMC active twinax cable.  Otherwise, you'll need to use optical since the Cisco switch will log an error if you attempt to use the Brocade cable."
    But going optical is very expensive, we have over 20 servers and we would need 40 SFP+ for CNA and 40 SFP+ for Cisco...
    I need someone who actually have  up and running connection btw Brocade CNA and N5K to share what he used

  • Connect Nexus 5548UP-L3 to Catalyst 3750G-24T-E Layer 3 Switch

    Please help!
    Could anyone out there please assist me with basic configuration between Nexus Switch and Catalyst Switch, so that devices connected on the catalyst switch can talk to devices connected on nexus switch and vice-versa? In my current setup all servers on VLAN 40 are connected on the Catalyst Switch A as shown in the diagram below, and all desktops and all other peripherals are connected on the Catalyst Switch B.  I am required to implement/add a new Nexus Switch 5548 that in the future will replace the Switch A. From now I just need to connect both switches together and start moving the server from Switch A to the Nexus Switch.
    The current network setup is shown as per diagram below:
    SWITCH A – this is a layer 3 switch. All servers are connected to this switch on the VLAN 40.
    SWITCH B – all desktops, VoIP telephones, and printers are connected on tis switch. This switch is also a layer 3 switch.
    I have connected together the Nexus 5548UP and SWITCH A (3750G) using the GLC-T= 1000BASE-T SFP transceiver module for Category 5 copper wire. The new network is shown as per diagram below:
    Below is the configuration I have created in both Switches:
    SWITCH A - 3750G
    interface Vlan40
    description ** Server VLAN **
    ip address 10.144.40.2 255.255.255.128
    ip helper-address 10.144.40.39
    ip helper-address 10.144.40.40
    interface Vlan122
    description connection to N5K-C5548UP Switch mgmt0
    ip address 172.16.0.1 255.255.255.128
    no ip redirects
    interface Port-channel1
    description UpLink to N5K-C5548UP Switch e1/1-2
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 1,30,40,100,101,122
    switchport mode trunk
    interface GigabitEthernet1/0/3
    description **Connected to server A**
    switchport access vlan 40
    no mdix auto
    spanning-tree portfast
    interface GigabitEthernet1/0/20
    description connection to N5K-C5548UP Switch mgmt0
    switchport access vlan 122
    switchport mode access
    spanning-tree portfast
    interface GigabitEthernet1/0/23
    description UpLink to N5K-C5548UP Switch e1/1
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 1,30,40,100,101,122
    switchport mode trunk
    channel-group 1 mode active
    interface GigabitEthernet1/0/24
    description UpLink to N5K-C5548UP Switch e1/2
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 1,30,40,100,101,122
    switchport mode trunk
    channel-group 1 mode active
    N5K-C5548UP Switch
    feature interface-vlan
    feature lacp
    feature dhcp
    feature lldp
    vrf context management
      ip route 0.0.0.0/0 172.16.0.1
    vlan 1
    vlan 100
    service dhcp
    ip dhcp relay
    interface Vlan1
      no shutdown
    interface Vlan40
      description ** Server VLAN **
      no shutdown
      ip address 10.144.40.3/25
      ip dhcp relay address 10.144.40.39
      ip dhcp relay address 10.144.40.40
    interface port-channel1
      description ** Trunk Link to Switch A g1/0/23-24 **
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,122
      speed 1000
    interface Ethernet1/1
      description ** Trunk Link to Switch A g1/0/23**
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,12
      speed 1000
      channel-group 1 mode active
    interface Ethernet1/2
      description ** Trunk Link to Switch A g1/0/24**
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,122
      speed 1000
      channel-group 1 mode active
    interface Ethernet1/3
      description **Connected to server B**
      switchport access vlan 40
      speed 1000
    interface mgmt0
      description connection to Switch A g2/0/20
      no ip redirects
      ip address 172.16.0.2/25
    I get a successful response from Server A when I ping the N5K-C5548UP Switch (VLAN 40 interface (10.144.40.3) .But if I try to ping from Server A to Server B or vice-versa the ping fails. From N5K-C5548UP I can ping successful either Server A or Server B. What am I doing wrong here? Is there any additional configuration that I need to add on the Nexus Switch? Please Help. Thank you.

    no, no secret aukhadiev
    I made a mistake without realising and the interface e1/3 was showing "Interface Ethernet1/3 is down (Inactive)". After spending sometime trying to figure out what was wrong with that interface or switch, it turned out to be that i forgot to add the vlan 40. Now the config looks like this:
    N5K-C5548UP Switch
    feature interface-vlan
    feature lacp
    feature dhcp
    feature lldp
    vrf context management
      ip route 0.0.0.0/0 172.16.0.1
    vlan 1
    vlan 40
    vlan 100
    service dhcp
    ip dhcp relay
    interface Vlan1
      no shutdown
    interface Vlan40
      description ** Server VLAN **
      no shutdown
      ip address 10.144.40.3/25
      ip dhcp relay address 10.144.40.39
      ip dhcp relay address 10.144.40.40
    interface port-channel1
      description ** Trunk Link to Switch A g1/0/23-24 **
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,122
      speed 1000
    interface Ethernet1/1
      description ** Trunk Link to Switch A g1/0/23**
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,12
      speed 1000
      channel-group 1 mode active
    interface Ethernet1/2
      description ** Trunk Link to Switch A g1/0/24**
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,122
      speed 1000
      channel-group 1 mode active
    interface Ethernet1/3
      description **Connected to server B**
      switchport access vlan 40
      speed 1000
    interface mgmt0
      description connection to Switch A g2/0/20
      no ip redirects
      ip address 172.16.0.2/25
    Thank you,
    JN

  • Storage direct connect

    Hello,
    Once we have the new 2.1(1) release for UCS Manager I'd like to know the following when using Fabric Interconnects in FC Switch Mode:
    1) Is it possible to connect a supported storage array directly to the Fabric Interconnects at the same time of having a Nexus/MDS connected as an uplink switch?
    2) Who will make the zoning in the latter case (MDS/Nexus or Fabric Interconnects)?
    3) Is it possible to set up zoning between two storage arrays connected to the Fabric Interconnects so that is possible to replicate storage from one array to the other?
    4) If storage array 1 is connected directly to the Fabric Interconnects while storage array 2 is connected to the Nexus/MDS uplink,is it still possible to zone and replicate between the two arrays?
    Thanks,

    Hi Dani,
    Answers to your questions below.
    1) Is it possible to connect a supported storage array directly to  the Fabric Interconnects at the same time of having a Nexus/MDS  connected as an uplink switch?
    [ANSWER] Yes, you can connect a storage array directly to the FI, but make sure that you put it in a different VSAN than the one connected to MDS/N5K. You can enable zoning on this new VSAN and do the zoning in FI.
    2) Who will make the zoning in the latter case (MDS/Nexus or Fabric Interconnects)?
    [ANSWER] Your existing zoning will remain same and the zoning will have to be in MDS/N5K. This VSAN will not have zoning enabled in UCS.
    3)  Is it possible to set up zoning between two storage arrays connected to  the Fabric Interconnects so that is possible to replicate storage from  one array to the other?
    [ANSWER] Replication is not possible through FI. If you have extra ports in new storage, you can connect those ports to MDS/N5K, and manage the replication through them.
    4) If storage array 1 is connected  directly to the Fabric Interconnects while storage array 2 is connected  to the Nexus/MDS uplink,is it still possible to zone and replicate  between the two arrays?
    [ANSWER] No, you wouldn't be able to do this as they will be in different VSAN's. Again this can be managed as mentioned in point 3 above.

  • WAN Router Connection to Data Center

    We have a WAN router that needs to connect to our Data Center network.  The Data Center consists of two N7K core switches, with a pair of N5K switches as aggregation, and each N5K has twelve N2K fabric extenders.  The N2Ks are single-homed to the N5Ks.  The N5Ks are vPC connected to the N7Ks.
    We would like to attach the WAN router to both N7K switches in the Data Center.  The N7K switches only have 10G ports in them, so we can't terminate the WAN router directly to the N7Ks.
    I was considering creating one dedicated VLAN on each N7K, and assigning an SVI to each VLAN, to correspond to the L3 connections between the N7Ks and the WAN router.  Then, we could trunk these VLANs to each of the N5Ks, and configure one 1G port on each N5K for the VLAN, and connect the WAN router to the N5Ks.
    Two questions regarding this design:
    1) Is there a problem in connecting the L3 WAN router to the N7K via the N5K?
    2) Does vPC connectivity between the N7K and N5K pose a problem for the proposed WAN connectivity?
    Thanks in advance for any feedback.
    -rb

    The vPC between N5K and N7K is the catch here. Layer-3 routing over vPC member ports is currently not supported so I will advise you to stay away from this approach.
    Atif

  • FI 6248 Nexus 5548 Port-channel problem

                       Hi all
    I have a strange behavior between 2 FI and 2 nexus 5k configured as VPC , From a remote location and from my desktop I can ping odd ip and not even , from an other desktop in the same LAN the reverse, for both the tracert are good.
    The only solution is to shutdown  ports 1/1-2 on nexus A or FI A and in that case both desktops can ping both IP.
    All seems OK, no log error , no error on interface , I give below some commands
    What thing to know is that the nexus b has a L3 card , not the Nexus A , In fact I am waiting for a spare L3 daughter card.
    On both NexusI have such configuration and status
    interface port-channel201
      description ucs-Fab-a
      switchport mode trunk
      switchport trunk native vlan 999
      spanning-tree port type edge trunk
      vpc 201
    UCSM-PARIS-A(SSI153000ST)
                           Eth1/1        129    S I s     UCS-FI-6248UP Eth1/11
    UCSM-PARIS-A(SSI153000ST)
                           Eth1/2        174    S I s     UCS-FI-6248UP Eth1/12
    sh port-channel summary
    201   Po201(SU)   Eth      LACP      Eth1/1(P)    Eth1/2(P)
    sh mac address-table dynamic | i 1010
    * 1010     0025.b5c9.481e    dynamic   0          F    F  Po201
    * 1010     0025.b5c9.481f    dynamic   10         F    F  Po201
    sh ip arp
    10.203.136.21   00:01:05  0025.b5c9.481f  Vlan1010
    10.203.136.22   00:12:43  0025.b5c9.481e  Vlan1010
    On both FI A have such configuration and status
    terface port-channel201
      description U: Uplink
      switchport mode trunk
      pinning border
      switchport trunk native vlan 999
      switchport trunk allowed vlan 1,104,999,1010-1013,1020-1021,1500-1502,1510-151
    2,1550-1552,1560-1561,1600-1602,1610-1619
      speed 10000
    sh port-channel summary
    201   Po201(SU)   Eth      LACP      Eth1/9(P)    Eth1/10(P)   Eth1/11(P)
                                         Eth1/12(P)
    sh mac address-table dynamic
    * 1010     0025.b5c9.481e    dynamic   0          F    F  Po201
    * 1010     0025.b5c9.481f    dynamic   0          F    F  Po201
    sh cdp nei
    E2RTR001(SSI1608085E)  Eth1/9          120     S I s       N5K-C5548UP   Eth1/1
    E2RTR001(SSI1608085E)  Eth1/10         120     S I s       N5K-C5548UP   Eth1/2
    E2RTR002(SSI16080F17)  Eth1/11         151     R S I s     N5K-C5548UP   Eth1/1
    E2RTR002(SSI16080F17)  Eth1/12         136     R S I s     N5K-C5548UP   Eth1/2
    Any ideas, A configuration I forgot on FI ?
    Regards .

    In fact in the probem I described the path is Esx -> FAB A - > N5K-A (for layer 2) -> N5K-B (for L3) -> routing to the LAN
    And what you told me is that such configuration is not supported with VPC configuration , so I need to wait to receive the L3 card for the N5k-A. and check later if I have the same problem.
    thanks

  • Cisco UCS - IOM to 6248 (FC)

    Hi All,
    Just a quick one - is anyone using FC to connect the 6248s to their IOMs ? I've reached the dreaded limit of the twinax cables.
    I can see it's supported but just want to check the configuration changes needed as I'm in a full production environment.
    Is it as simple as plugging in the SFPs and configuring a server port or do I need to change the UP to FC only which would require a re-boot of the 6248.
    Cheers
    Steve.

    Steve,
    We just need to configure the port type as " Server "  and use the optical / FET SFPs to connect to Fibre channel link.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/hw/chassis/install/install.html#wp1275791
    http://www.cisco.com/en/US/prod/collateral/ps10265/ps11544/data_sheet_c78-675245.html
    HTH
    Padma

  • Nexus 5500-UP licensing

    I'm trying to build a config for a Nexus N5K-C5548UP-FA that will have a mix of FCoE and native fibre channel ports.  What licensing do I need to purchase for the chassis to support this functionality?  I'm not anticipating that any of the FC connections will be to other MDS appliances if that matters.
    Specifically, when do I need these:
    N55-8P-SSK9
    N55-48PF-SSK9
    N5548-FNPV-SSK9
    thanks,
    ds

    Current FC FCOE licensing model on N5K is honour based.which comes in increment of 8.
    (N5K-8P-SSK9)  8 port  FC license .
    However future model is going restrict on port based lcienses.
    After installing N5K-8P-SSK9  license file which is called storage protocol service license.
    you would see
    "show license usage" output show as
    ENTERPRISE_PKG                Yes   -   Unused Never       -
    FC_FEATURES_PKG               Yes   -   Unused Never    
    N55xx-FNPV-SSK9 is only for FCoE NPV mode, not for FC NPV mode. If you'd like to run FC NPV mode you need the Storage Services License, this license also includes the FCoE NPV license.
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/san_switching/503_n2_1/Cisco_n5k_nxos_sanswitching_config_guide_rel503_n2_1_chapter6.html#topic_5492D4043C0746BFBE94FE6E2EBF7397

  • Nexus switch for storage

    we are currently evaluating solutions for our storage upgrade.
    we required 10GbE connection from storage to our servers.
    there are 2 proposals that uses nexus switch.
    1 uses nexus 5548 while the other one uses 3524.
    i understand that 5548 is of a higher grade than the 3524.
    i have 7 dell servers that will be connected to the switch using 10GbE NIC.
    which nexus switch is more suitable for my environment.
    7 servers -> 2 10GbE iSCSI switch -> 1x iSCSI storage(20TB)

    Well...you're on a Cisco forum, so we'd be remiss in not recommending Cisco gear. 
    The Nexus 5548UP is around 17k for the base model without any special layer 3 licenses. 
    http://www.softchoice.com/catalog/en-us/hubs-switches-cisco-nexus-5548up-switch-managed-N5K-C5548UP-FA-HV7684
    If you don't use layer 3 on the Nexus (which I wouldn't), they've got pretty good port density for the cost.  NXOS takes little bit of getting used to and, for us, the copper SFPs have been a royal pain in the ass, but otherwise, they're pretty solid devices. 

  • Nexus 5548UP L3 card swap out for L2 cards

    Hi everyone,
    I have two Nexus 5548UPs and I am going to swap out the L3 cards and put in L2 cards.
    I can't seem to get a straight answer out of TAC so I thought I'd try here.
    How will this affect the current configuration (apart of course from removing the L3 capability)?
    Will swapping the cards clear the config?
    Will swapping the cards clear the licenses?
    It's a very simple config so that doesn't worry me that much .. but if it will clear the licenses installed than I need to take action on that.
    Thanks,
    BR

    no, no secret aukhadiev
    I made a mistake without realising and the interface e1/3 was showing "Interface Ethernet1/3 is down (Inactive)". After spending sometime trying to figure out what was wrong with that interface or switch, it turned out to be that i forgot to add the vlan 40. Now the config looks like this:
    N5K-C5548UP Switch
    feature interface-vlan
    feature lacp
    feature dhcp
    feature lldp
    vrf context management
      ip route 0.0.0.0/0 172.16.0.1
    vlan 1
    vlan 40
    vlan 100
    service dhcp
    ip dhcp relay
    interface Vlan1
      no shutdown
    interface Vlan40
      description ** Server VLAN **
      no shutdown
      ip address 10.144.40.3/25
      ip dhcp relay address 10.144.40.39
      ip dhcp relay address 10.144.40.40
    interface port-channel1
      description ** Trunk Link to Switch A g1/0/23-24 **
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,122
      speed 1000
    interface Ethernet1/1
      description ** Trunk Link to Switch A g1/0/23**
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,12
      speed 1000
      channel-group 1 mode active
    interface Ethernet1/2
      description ** Trunk Link to Switch A g1/0/24**
      switchport mode trunk
      switchport trunk allowed vlan 1,30,40,100-101,122
      speed 1000
      channel-group 1 mode active
    interface Ethernet1/3
      description **Connected to server B**
      switchport access vlan 40
      speed 1000
    interface mgmt0
      description connection to Switch A g2/0/20
      no ip redirects
      ip address 172.16.0.2/25
    Thank you,
    JN

  • Nexus 5548UP and GLC-LH-SM showing sfpinvali

    Hi gurus, have just received a 5548UP and when a 1GB GLC-LH-SM is inserted into the system it shows as being invalid.
    Eth0/1       --                 sfpInvali 1         auto  10G     1/10g
    4 different SFPs have been tried in numerous interfaces on the system.  I have also upgraded the software to 5.0(2). 
    And I have tried setting the speed to 1GB on the interface.
    Any ideas on what simple configuration task I have missed?
    LP

    Hi,
    I've the same issue with GLC-T 1Gbps SFP tranceiver and NX-5548UP with L3 Daughter Card.
    sh int e1/32 status
    Port          Name               Status    Vlan      Duplex  Speed   Type
    Eth1/32       VLAN99             notconnec 99        full    1000    SFP-1000BAS
    The cable is connected and in the other device (switch 2960x) the ethernet interface is UP
    My configuration :
    NX-OS : version 5.2(1)N1(4)
    interface Ethernet1/32
      description VLAN99
      switchport access vlan 99
      speed 1000
     sh mod
    Mod Ports Module-Type                       Model                  Status
    1   32    O2 32X10GE/Modular Universal Plat N5K-C5548UP-SUP        active *
    3   0     O2 Daughter Card with L3 ASIC     N55-D160L3-V2          ok
    Tranceiver info :
    Ethernet1/32
        transceiver is present
        type is SFP-1000BASE-T
        name is CISCO-METHODE   
        part number is SP7041_Rev_E    
        revision is E   
        serial number is 00000MTC163405CF
        nominal bitrate is 1300 MBit/sec
        Link length supported for copper is 100 m
        cisco id is --
        cisco extended id number is 4
    DOM is not supported
    Interface capa :
    Ethernet1/32
      Model:                 N5K-C5548UP-SUP
      Type (SFP capable):    10Gbase-(unknown)
      Speed:                 1000,10000
      Duplex:                full
      Trunk encap. type:     802.1Q
      Channel:               yes
      Broadcast suppression: no
      Flowcontrol:           rx-(off/on),tx-(off/on)
      Rate mode:             none
      QOS scheduling:        rx-(6q1t),tx-(1p6q0t)
      CoS rewrite:           no
      ToS rewrite:           no
      SPAN:                  yes
      UDLD:                  yes
      Link Debounce:         yes
      Link Debounce Time:    yes
      MDIX:                  no
      Pvlan Trunk capable:   yes
      TDR capable:           no
      FabricPath capable:    yes
      Port mode:             Switched
      FEX Fabric:            yes
    Any idea ?
    Regards,
    Julien.

  • Partial collection Failure for nexus 5548UP in PI 2.1

    Hi there,
    I get "Partial Collection Failure" in the inventory collection status in Prime Infrastructure for all my Nexus 5548UP (8 devices).
    i have seen in the PI 2.1 release notes that a bug CSCum16230  which look like my problem has been resolved in PI 2.1 but i continue getting the "partail collection failure"
    Would like to know if the bug is still exist or get any other help to solve this problem.
    Regards,
    Alon.

    hello
    I have this problem as well...
    we've got four N5K-C5548UP. Two with a layer 3 daughter card and two without.
    interestingly we see the issue just on those boxes with the l3 daughter cards N55-D160L3-V2 installed...
    Any help or ideas are highly appreciated
    regards
    roman
    Sh inventory:
    OK:
    device-a# sh module
    Mod Ports Module-Type Model Status
    1 32 O2 32X10GE/Modular Universal Pla N5K-C5548UP-SUP active *
    3 0 O2 Non L3 Daughter Card N55-DL2 ok
    Mod Sw Hw World-Wide-Name(s) (WWN)
    1 5.1(3)N2(1c) 1.0 --
    3 5.1(3)N2(1c) 1.0 --
    NOT OK:
    device-b# sh modu
    Mod Ports Module-Type Model Status
    1 32 O2 32X10GE/Modular Universal Pla N5K-C5548UP-SUP active *
    3 0 O2 Daughter Card with L3 ASIC N55-D160L3-V2 ok
    Mod Sw Hw World-Wide-Name(s) (WWN)
    1 5.1(3)N2(1c) 1.0 --
    3 5.1(3)N2(1c) 1.0 --

Maybe you are looking for

  • Shutting down database hangs

    Dear Gurus, I m facing a database hang issue while performing the scheduled offline backup.I m able to take the online backup.When the backup starts , the database starts to shutdown.When checked in the log of backup it shows in tail as shutting down

  • Problems with symlinks and include directives

    Any files that are included with an include directive from a file that is           contained in a directory that is reached via a soft link do not work           (resource not found error) if the link begins with "../".           directory structure

  • Keyboard modifiers not working inDesign CC

    Hello everyone For some reason none of my keyboard modifiers are working Alt, CMD, Shift, Space etc etc At first I just thought it was the space bar to pan, but now nothing is working - scale proportionally, nothing! Does anyone have any ideas?? I've

  • Apply form template to existing PDF

    Is it possible to apply a pre-defined form template to existing PDF files in Acrobat Pro 9? Basically I just want to apply 2 signature fields to a pdf document (manufacturing drawing) using some sort of preset. This would get around having to re-crea

  • [solved] Permissions issue - can't mount usb device as user, just root

    In my last post I learned how to mount a secondary HDD from the command line.  Problem is I did it as root. Now I have xfce4 running and I need mount permissions as user. Here's my fstab: [dennis@archlinux media]$ cat /etc/fstab # /etc/fstab: static