Connect Digital port PFI2 to RTSI3

i have a question about connecting a digital port (e.g. PFI2) to RTSI port (e.g. RTSI3).
My device: PCI6731
i have already sucessfully connected 'Ctr0InternalOutput' to RTSI0.
Now I need a digital input to another RTSI. But I failed to do that and got the prompt message: 'Specified route cannot be satisfied, because it requires resources that are currently in use by another route.'
Please tell me how to connect a digital input to a RTSI?
Thank you!

Greetings lyonco.
This is a great question and can be somewhat of a tricky task at times.  For advice on how best to proceed, please refer to the following KnowledgeBase article. 
Why Do I Get Error 89137 "Specified route cannot be satisfied..." When Routing PFI Lines Over RTSI?
In the case of the PCI-6731, it appears from the routing table that Counter0 is used as a subsystem when routing from any of the PFI lines to RTSI0-6.  I hope this information helps get you on the right track. 
Regards,
Michael G.
Michael G.
Applications Engineer
National Instruments
Self-realization: I was thinking of the immortal words of Socrates, who said, "... I drank what?"

Similar Messages

  • Connecting inductif approximation sensor to digital port

    Hi,
    As I have little experience in electronics I was wondering how I could
    connect a inductif approximation sensor to one of my digital ports of a
    PCI-MIO DAQ card. This card has 8 digital ports which can be configured as
    either digital in or out.
    The sensor is driven by 24 volts DC, three wires, and is of PNP type.
    Anyone?
    thanks
    I'd like to use this sensor to monitor the speed of a slow rotating machine.
    Ron@ld

    Ronald
    If the signal from the signal is withen TTL specs, you can use it with one of the digital ports on the E-Series boards. TTL specs are 0 - 0.8V for low and 2-5V for high. The rise and fall times will also have to be within TTL specs.
    Brian

  • TA25199 how to connect digital octical audio cable to my sony internet tv w/bose cinimate 1SR

    how to connect digital octical audio cable to my sony internet tv  w/ bose cinimate 1SR

    I took the cable and connected it to my atv's optical port
    then I pulled the cable and connected it to my receiver and then
    it played audio

  • Not able to start the Connection Digital Networking Replication Agent Service

    Hi All,
         I am getting the following alert through RTMT, when i tried to start the service in Unity Connection Serviceability, it doesn't start.   Unity Connection 8.5.1.  It is still in the stopped status, Although service is not important, however it is pushing a lot of rtmt alert.   Could you please help me how to start this Connection Digital Networking Replication Agent Service. 
    Service operational status is DOWN. Connection Digital Networking Replication Agent.
    Thanks
    Barry

    Thanks for Nadeem and Aokanlawon, for the quick reply.
    1.  You are right  i got only one cluster i understand its not working,  However howcome this service was started in pub UC and was working. I will disable anyway now as i got only one cluster. It all started when I started to fix the following alerts which was pushed by sub Unity Connections(Branchsite)
    Failed to retrieve DbSpace usage information when running the "Monitor the Unity Connection databases" SysAgent task.
    This alert started coming after there was a network connection drop between HQ cucm and the branch sub UC, after the drop, all ports disconnected between these two servers, services deactivated in Sub UC, after the network connection back again, ports connected back and the most of the services activated.  However the following services were not in the running state in Sub UC.   I found these information from the sysagent trace log.  I thought to fix this error  is to start the Connection Database Proxy in Sub UC.  However this has stopped the following service 'Connection' Database Proxy' and 'Connection Digital Network Replication Agent' in Pub UC.  I managed to start Connection Database Proxy in Pub UC, however Connection Digital Network Replication agent is now in deactivated status.
    Critical Services
    connection exchange notification web service
    connection mailbox sync
    connection message transfer agent
    connection notifier
    Optional services
    Connection Database Proxy
    Connection Digital Networking Replication Agent
    Connection Speechview processor
    2. How do I stop the alert from sub UC
    Failed to retrieve DbSpace usage information when running the "Monitor the Unity Connection databases" SysAgent task.
    Thanks

  • My daq card PCI6025e' digital ports PA,PB,PC are in high state and cannot be changed even in MAX 2.1 testing panel and continuously output 5 volts even set for output.

    my digital ports PA,PB,PC are in high state and cannot be set low even if it is set for outputs.
    Thanks

    The MAX utility is the closest to the driver level and will eliminate software configuration as a possible issue. Please disconnect anything that you have connected to the DIO lines.
    Use the MAX test panel for your DIO lines, configure them as outputs, and set them to a low state. Use a multimeter (DMM) to observe the line state. If it is still high then you may have a problem with your hardware. If this is the case, I advise calling National Instruments support and investigate a possible RMA (repair).
    Best Regards,
    Justin Britten
    Applications Engineer
    National Instruments

  • Audio in/optical digital port

    I just traded out my G4 PowerPC Tower for a 17" MacBook Pro. I kept my original accessories (cinema display, mouse, keyboard) and the round, clear Apple speakers that came with it. I'd like to use the speakers but there's no applicable port. Is there a convertor or external female-male plug available to connect my audio in/digital port on the MacBook to my mini jack on the speakers? JL

    I never expected APPLE wouldn't make a mac that didn't have a proper mic jack?
    It has a proper one, a good one, a professional one, not the toy that comes with most PCs. Apple has used line level analog audio input for years.
    From Wikipedia;Line level is a term used to denote the strength of an audio signal used to transmit analog sound information between audio components such as CD and DVD players, TVs, audio amplifiers, and mixing consoles.
    In contrast to line level, there are weaker audio signals, such as those from microphones and instrument pickups, and stronger signals, such as those used to drive headphones and loudspeakers. The strength of the various signals does not necessarily correlate with the output voltage of a device; it also depends on the source's output impedance, or the amount of current available to drive different loads.

  • Database account locked as it tries to connect different ports for 16 times

    I need a help in answering one of the issue encountered last week.
    I have created a database link and tried to access the information from a table using the program written in another language. The password provided was incorrect for that user while creating database link. So we expected that,while retrieving the data, Database connection has to be errored out as password provided is incorrrect.
    But unfortunately, user account was locked out. When i checked with DBAs they mentioned that it tries to connect 16 ports with in a min of time.we were shocked as it STOPS another scheduled jobs with that user. and affects production badly.
    As per the program, it has to connect only one time and yesterday we tried to execute the program in DBAs observation and it errored out as expected. Didn't tried for multiple ports.
    Now the question is, WHY the database connection established 16 times last week and caused user account locked. DBAs are unable to answer it. Any EXPERTs opinion on this would greatly appreciated.
    I have verified managing ports in oracle documentation, it was mentioned that if one port is busy it will try to connect to another port in the range of ports mentioned during the installtion. DBAs verified ports related file and it was blank. and they are not agreeing with this reason. Please HELP me in finding the correct REASON for this.
    is it a NETWORK issue or issue with DATABASE SERVER only?
    Thanks
    SSP
    Edited by: 960738 on Sep 22, 2012 9:13 PM

    960738 wrote:
    I need a help in answering one of the issue encountered last week.
    I have created a database link and tried to access the information from a table using the program written in another language. The password provided was incorrect for that user while creating database link. So we expected that,while retrieving the data, Database connection has to be errored out as password provided is incorrrect.
    But unfortunately, user account was locked out. When i checked with DBAs they mentioned that it tries to connect 16 ports with in a min of time.we were shocked as it STOPS another scheduled jobs with that user. and affects production badly.
    As per the program, it has to connect only one time and yesterday we tried to execute the program in DBAs observation and it errored out as expected. Didn't tried for multiple ports.
    Now the question is, WHY the database connection established 16 times last week and caused user account locked. DBAs are unable to answer it. Any EXPERTs opinion on this would greatly appreciated.
    I have verified managing ports in oracle documentation, it was mentioned that if one port is busy it will try to connect to another port in the range of ports mentioned during the installtion. DBAs verified ports related file and it was blank. and they are not agreeing with this reason. Please HELP me in finding the correct REASON for this.
    is it a NETWORK issue or issue with DATABASE SERVER only?
    Thanks
    SSP
    Edited by: 960738 on Sep 22, 2012 9:13 PMDBLINK is 100% oblivious to the fact any port exists.
    DBLINK only contains username, password & TNS Alias.
    can you post actual SQL & results?

  • Problem with socket programming-connecting to port 13

    Hi, I am learning JAVA, and we are on the subject of sockets. I am trying to make this program to connect to port 13, get the time, and print it to the console. This is my code:
    import java.io.*;
    import java.net.*;
    public class temp {
         public static final int PORT = 13;
         public static void main(String[] args) {
              Socket s = null;
              String line = null;
              try {
                   s = new Socket("localhost", PORT);
                   DataInputStream sin = new DataInputStream(s.getInputStream());
                   line = sin.readLine();
                   if (line != null) System.out.println(line);
              catch (IOException e) {System.err.println("!" + e);}
              finally {
                   try { if (s != null) s.close(); }
                   catch (IOException e2) {}
    And this is the output:
    !java.net.ConnectException: Connection refused: connect
    What should I do. I found that the problem is with the server I am connecting to and I tried connecting to dif. computers, or to stuff online, and nothing works.
    Any suggestions for me?
    Forgot: I tried this on both a windows XP and Vista
    Edited by: xpatrickerx on Mar 23, 2008 8:12 PM
    Tampering with it, I find that the error occurs on the following line:
    s = new Socket("localhost", PORT);
    Edited by: xpatrickerx on Mar 23, 2008 8:13 PM

    So I finally found how to use printStackTrace and here is what it gives when:
    1) I use my own computer:
    java.net.ConnectException: Connection refused: connect
         at java.net.PlainSocketImpl.socketConnect(Native Method)
         at java.net.PlainSocketImpl.doConnect(Unknown Source)
         at java.net.PlainSocketImpl.connectToAddress(Unknown Source)
         at java.net.PlainSocketImpl.connect(Unknown Source)
         at java.net.SocksSocketImpl.connect(Unknown Source)
         at java.net.Socket.connect(Unknown Source)
         at java.net.Socket.connect(Unknown Source)
         at java.net.Socket.<init>(Unknown Source)
         at java.net.Socket.<init>(Unknown Source)
         at temp.main(temp.java:11)
    2) I use something else:
    java.net.ConnectException: Connection timed out: connect
         at java.net.PlainSocketImpl.socketConnect(Native Method)
         at java.net.PlainSocketImpl.doConnect(Unknown Source)
         at java.net.PlainSocketImpl.connectToAddress(Unknown Source)
         at java.net.PlainSocketImpl.connect(Unknown Source)
         at java.net.SocksSocketImpl.connect(Unknown Source)
         at java.net.Socket.connect(Unknown Source)
         at java.net.Socket.connect(Unknown Source)
         at java.net.Socket.<init>(Unknown Source)
         at java.net.Socket.<init>(Unknown Source)
         at temp.main(temp.java:11)
    Again, thanks

  • Single virtual channel with multiple digital ports

    Hi all,
    I have created a program that creates a task to read continuously from 3 digital port lines from the same device (PXI-6133). I am trying to figure out how I can retrieve the data from each port line to put into a waveform graph. Currently, I am using the DAQmx Read instance with "1 Channel N Samples" but I get a waveform with all values at the same time or a waveform graph with all three lines transposed.
    I am using Windows XP and LabVIEW 8.6.
    Appreciate any help!
    Solved!
    Go to Solution.

    Hi Matt,
    Thanks for your reply. Unfortunately thats not quite I am looking for. I am sending the DAQmx task the 3 port lines that I want therefore as I have read it bundles them all into one channel by default. What I want to do is take that one channel and parse out the data of each of the 3 port lines to create 3 new waveforms to work with individually.
    After fumbling around a little bit, I was able to sort of get what I wanted. I've attached a screen shot of that portion of the program. The red circle in the bottom right hand corner is how I want to end up. I only did it for one of the pieces of data just to try it out and the conversion to string is just for me to print out what I'm working with. Unfortunately, when I look at the waveform it seems like maybe some extra 0's are being thrown in because its not the same graph that appears from the beginning (when all 3 pieces of data are transposed on each other). Let me know what you think.
    Thanks,
    julissa
    Attachments:
    LabVIEW-ss1.JPG ‏57 KB

  • Write to serial port and digital port at the same time

    hello,
    I need to write to the digital port and the serial port at the same time. Right now I have the two vi's (to write to the serial port, write to the digital port) in the sequence structure. First I write the digital port, then write the serial port. Using the oscilloscope, the interval between these two executions is 10 ms; and I need to reduce this interval to as small as possible. I would appreciate help in any way. Thank you.

    Hello;
    This is a little tricky. Since the transition from one sequence to another is completely Software timed, and windows manages all tasks that are running at one given time, there isn't a method to reduce that transition time.
    The most you can do is try to optimize your code so all the time expent on the transition is due only to the task management.
    Hope this helps.
    Filipe A.
    Applications Engineer
    National Instruments

  • I write digital port by 'DAQmx Configure Logging.vi​' and receive TDMS file with 8 boolean channels. How can I write to 1 integer channel?

    Hello!
    I want to write 1 digital port from PXI-6536 with streaming to TDMS file.
    I'm writing by 'DAQmx Configure Logging.vi' and become TDMS file with 8 boolean channels.
    How can I write to 1integer channel?
    Attachments:
    1.JPG ‏27 KB

    Hey Atrina,
    The actual data stored on disk is just the raw data (that is, a byte per sample in your case).  It's really just a matter of how that data is being represented in LabVIEW whenever you read back the TDMS file.
    I'm not sure if there is a better way to do this, but here is a way to accomplish what you're wanting:
    Read back the TDMS file as a digital waveform.  Then there's a conversion function in LabVIEW called DWDT Digital to Binary.  This function will convert that set of digital channels into the "port format" that you're wanting.  I've attached an example of what I mean.
    Note: When looking at this VI, there are a few things that the downgrade process did to the VI that I would not recommend for these TDMS files.  It added a 1.0 constant on the TDMS Open function, and it set "disable buffering" on the TDMS Open function to false; you can get rid of both of those constants.
    Message Edited by AndrewMc on 01-27-2010 11:21 AM
    Thanks,
    Andy McRorie
    NI R&D
    Attachments:
    digitalconvert.vi ‏13 KB

  • Connected Digital AV Adapter to HDMI HD TV. Photo slideshow works fine but cannot play iTunes playlist concurrently (with sound turned off on slideshow)

    Connected Digital AV Adapter from my iPad (64 GB 4G) to my HD TV. Tried playing slideshow (with sound off) concurrently with playing iTunes playlist. Video plays fine but no audio. iTunes volume indicator not showing any volume.

    Just following-up on this posting from a week or two ago and another a few days later about the problems with catch-up TV.  We were disappointed with the lack of service, but as we can get most of the catch-up we want on the Sony Bravia TV, hadn't pursued it with BT perhaps hoping things would improve.
    Got a phone call last week from BT asking if we'd been able to set up the YouView Box OK, which we had.  Mentioned the unsatisfactory service.  She immediately put me through to the BT technical call centre in India where I spoke to guy called Rajiv or something like that.  Asked a few questions and then asked me to switch off the YouView Box (back panel switch) and do a hard-reset on the Homehub Router.  Once this had been done, and the YouView box switched back on.  The service ran fine and has done so since.  I don't know if Rajiv did anything in the network or whether this is just some problem (he called it a "glitch") in the router/YouView box.  Funny that that the speedtest and streaming to the Sony TV works OK.
    He phoned back a couple of days later to see if we'd had any further problems.  Overall good service.  It would be interesting to know from a technical point of view what the problem was and how it was solved.  It shouldn't be necessary to reset boxes in this way.

  • Error Message "The Remote device or resourse wont accept connection, not set up to accept connection from port https"

    I get this error message when trying to open and log into an online casino "The Remote device or resource wont accept connection, not set up to accept connection from port https".
    I am on a desktop computer my connection to the net is with a USB Virgin Mobile hotspot device.
    I also have issues with some downloads not installing right for instance SKYPE wont work. If the problems are related I don't know
    Thanks

    Starting in Firefox 14, Firefox will guess an address and place it in the address bar (AutoFill feature). If you have ever connected to the site using a secure (HTTPS) connection, then Firefox will try to connect security to the address suggested by the AutoFill feature. To work around this you can:
    * Edit the address to force Firefox to interpret your entry literally. For example, if there is a trailing / you can remove it.
    * Turn off the URL bar AutoFill feature and just use the AutoSuggest drop-down.
    * Clear Firefox's memory of the site so it doesn't default to a secure connection (however, this also removes any bookmarks you have to pages on the site).
    To disable the in-address-bar autofill without losing the suggestions that appear below the bar:
    (1) In a new tab, type or paste '''about:config''' in the address bar and press Enter. Click the button promising to be careful.
    (2) In the filter box, type or paste '''autofill''' and pause while the list is filtered
    (3) Double-click '''browser.urlbar.autoFill''' to toggle it from true to false. You're done with about:config and you can close this tab.
    "Forget about this site" will clear cache, history, bookmarks, and permissions for the site, and probably any saved certificate. There are two ways to get to this:
    * History > Show All History, right-click an entry for the site > "Forget about this site"
    * Type or paste about:permissions in the address bar and press Enter, then select the site from the list on the left side, and click the "Forget about this site" button on the right side
    Depending on the size of your history and cache, this may lock Firefox up for a minute or two while everything is cleansed.

  • How to avoid dependance between output digital port with a PCI 1200 daq card?

    Hello,
    I don't manage to fix the state of a line on one port (PA0 for ex) without change the state of another line of another digital port (PB0 for ex)
    I use a PCI 1200 Daq card with Labview 5.0.1 (under Windows 98)
    How to configure a robust state (high logic level) on a line of a port??
    Does anybody have an idea on this problem?
    Thanks a lot in advance and happy new year to the community
    JF LAVEZARD

    jflab a écrit:
    Hello,
    I don't manage to fix the state of a line on one port (PA0 for ex) without change the state of another line of another digital port (PB0 for ex)
    I use a PCI 1200 Daq card with Labview 5.0.1 (under Windows 98)
    How to configure a robust state (high logic level) on a line of a port??
    Does anybody have an idea on this problem?
    Thanks a lot in advance and happy new year to the community
    JF LAVEZARD
    Hello,
    I've found the problem
    The PCI1200 has a chip 8255 for Digital I/O
    If I use the bad VI, it reconfigures the port and all the lines go in a low logic state
    so I'd to write only on the port or the line without reconfigure the port
    So the good VI in the palett is: Port Write and not Digital Port write!
    See attached file..
    Thanks
    Best Regards
    Attachments:
    port_dio.jpg ‏771 KB

  • Can I use straight cable to connect trunk ports between 2 switches?

    Hi,
    Am I able to use straight instead of cross cable to connect trunk ports between 2 switches??
    thanks!

    Hi Devang,
    When a 10/100 Fast Ethernet interface is enabled, one end of the link must perform media dependent interface (MDI) crossover (MDIX), so that the transmitter on one end of the data link is connected to the receiver on the other end of the data link (a crossover cable is typically used).
    The Auto-MDIX feature eliminates the need for crossover cabling by performing an internal crossover when a straight cable is detected during the auto-negotiation phase.
    HTH, if yes please rate the post.
    Ankur

Maybe you are looking for

  • How to show multiple dynamic tables on a single screen?

    right now im displaying alv for singlr attribute of dimension. eg for dimension PRODUCT attribute PROFITCENTER im displaying in alv when user executes it. but the requirement is that multiple attributes can be there so multiple tables is to be displa

  • How do I find out the ID number for a Podcast?

    I want to link to a few different podcasts in itunes from my website . I have seen links that include a podcast ID number, such as ...viewPodcast?id=xxx, but I can not see where to find the ID number of the podcasts I want to link to. Has any done th

  • How to get extension version number to update in exchange panel.

    I was able to upload my Illustrator extension, set it to private and share it. Brialliant functionality. Now I have released a point update, and although it shows the correct version in the extension details on the Adobe Exchange website, the version

  • Itunes cannot connect to my ipod touch

    I have uninsalled and reistalled itunes, but to no avail.  I have followed all of the links on the support pages too, but nothing seems to owrk. I keep getting the following message when I log into ITunes "itunes could not connect to this ipod as an

  • Dashed Line - Dashes Move?

    I'm trying to make a dashed line move, sort of like what you see in photoshop when you outline something. Basically I want the dashes to move along a path. Usually I can come up with these solutions pretty quickly, but I'm not able to on this one. Ma