Connect to a backend system with the BI connector via Visual Composer
Hi all,
I set up a system landscape on my notebook with the NW2004s ABAP as NSP and with the NW2004s JAVA SP7 as J2E. Both systems are integrated in the SLD, this is set up. Furthermore I installed a BI system alias as NSP_XMLA in the portal with the URL for the backend system: http://localhost:8000/sap/bw/xml/soap/xmla.
I have the same user on portal and backend system NSP. Both have admin previleges.
When I try to logon to the backend system with this URL I get this error:
"No switch to HTTPS occurred, so it is not secure to send a password"
" Choose "Logon" to continue A dialog box appears in which you can enter your user and password"
Then I can logon to the server and get a lot of XML.
But I have to manually logon to the system.
From the portal I cannot logon to the backend system with the test function. I get the error:
Alias is found, but connection failed.
I guess there must be an automatic logon preconfigured.
How can I do this?
Is SSO necessary?
thanks for any help
Hi Gregor,
thanks for your answer, which was intersting but could not solve the problem. In the meantime I discoverd the reason for it.
You have to insert the connection URL to the BW system at 2 points in the system.
1. You have to configure the XMLA connector with the Visual Administrator.
2. You must implement a system in the portal where you configure all necessary information, also the URL to the BW system.
This seems somewhat strange to me because you will then not be able to connect with two or more BW systems to the portal and VC what is centainly necessary in a real world scenario. Anyway I can now see all Infoproviders of the BW system in the VC, and SSO isn't necessary because you configure the information to login to the BW system directly in the configuration of the XMLA connector in Visual Administrator.
Similar Messages
-
Create a sequence of actions in the toolbar button in Visual Composer
Hi!
I've a problem with the toolbar buttons in visual composer. On a table, I would like to have one button which launch 2 actions. For example, I want to call an event (custom action) and after that I want to select a row in another table (system action, select).
It works fine when I create 2 buttons with the toolbar buttons but my wish is to have only one button with several actions (like a sequence of actions). Is it possible?
Thanks for any help!Hi Ronan,
I think you can achieve your requirement by creating the Wizard in SAP Visual Composer.
The following link provides the detailed steps to Create the Wizard in SAP VC.
http://help.sap.com/saphelp_nw04s/helpdata/en/88/fedb4269b2f340e10000000a1550b0/content.htm
Please have a look.
Thanks,
Prashant
(Please reward points for useful answer) -
User cannot connect to backend system with user J2EE_ADMIN.
I am using Rapid Installer to initiate the second part of the installtion "ERP 6.0 EhP 3 Self-Service Scenarios and Automatic Roles". When I get to the J2EE User section to enter the parameters, the user is defaulted to "Administrator" and I enter my password. I click next and get this message "User cannot connect to backend system with user J2EE_ADMIN." Any ideas?
If this is a double stack installation, you need to enter J2EE_ADMIN as user, NOT administrator.
Markus -
How to connect SAP R/3- System with SAP NetWeaver Portal (2004s)?
Hello to all,
sorry, can someone help me? How can I connect SAP R/3- System with SAP NetWeaver Portal (2004s)?
Thanks and regards,
GalynaHi,
In previous link contain this info
This describes how to connect an SAP R/3 system to SAP NetWeaver Portal using an iView
1) Go to System Administration
2) Go to System Configuration
3) Go to Portal Content (Right Side Panel), open that folder.
4) Right Click on Portal Content, a Panel is displayed select "System (from Template)".
5) That will display a new view on right side, now select "SAP system using dedicated application server" from
the existing templates. (Other templates are possible - for example, load balanced or through a SAProuter connection string).
For this exercise, we'll use the simplest type.
6) Choose next
7) Give the System Name and System Id (which are mandatory fields) incase you want to give any brief notes
about the system then give them in the "Description" field.
8) Open the Newly Created System.
9) Now when you want to create a New System, you have to fill four Properties they are:
"Connector" - contains basic connectivty details
"Internet transaction Server (ITS) - if you wish to use SAPGUI for HTML and/or IACs",
"Web Application Server" - if you wish to access BSPs and/or Web Dynpro for ABAP and
"User Management".
You also need at least one "System Alias" has to be defined from the Display drop down menu.
Make sure you have set end user access in the Permissions drop down menu to all users who need to access the system
10) Select "Connector" property, now fill the required fields such as:
a) Application Host (should be fully qualified hostname) - Give the R/3 "Application Name",
which can be obtained from the SAP Logon Pad (check what R/3 system you are using, right click on it , go to the properties,
it will open a window which has the Application Server Name.
b) Logical System Name - Give the logical name as defined in the backend system
c) SAP Client - Check the Client in the backend system and give the appropriate number (3 digits)
d) SAP System ID(SID)* - Check the R/3 properties and give the check for System ID
e) System Type* - Since we are connecting to R/3, select SAP_R3 system.
f) System Number - This is a two digit number that you can find in the SAP Logon Pad
11) Select "Internet transaction Server (ITS)" property, now fill the required fields like
a) ITS Description à Give some Description
b) ITS Host Name - Same as "Application Host" of R/3 (when integrated ITS) and should be attached with the
port number of ITS Server (to get port number detailed description is given below). ex: hostname : port number
c) ITS Path - To get the path along with the port number you have to Log on to R/3 system. Use the
Transaction Code "SICF", it opens a new window go to:
default_host -> sap -> bc -> gui -> sap -> its -> webgui -> SAP GUI for HTML -> right click on
that and click "Test Service'. This will open a new window, on the address bar you will find the "port number", and
the path something like (/sap/bc/gui/sap/its/webgui). Use the path after the port number.
d) ITS Protocol - There are two protocols "http" & "https", select the appropriate protocol which is
visible when you opened "Test Service" window.
12) Select "Web Application Server" property , now fill the required fields like
a) Web AS Description -> Give some Description
b) Web AS Host Name - same as ITS Host Name
c) Web AS Path - usually /sap/bc/bsp/sapd)*
Web AS Protocol - should be same as the ITS Protocol.
13) Select "User Management" property, now fill the required fields like
a) Authentication Ticket Type - Since we are not using SSO leave the field
empty i.e. put in select mode. (Please note that longer term you will probably want to use SSO)
b) Logon Method - Select UIDPW.
c) User Mapping Type - In case you have administration rights then you choose "admin" or in case you
just have user rights then choose "user", better go for "admin/user".
14) Since all the required fields are filled appropriately now create a System Alias name, this can be done by following steps:
a) go to Display -> Select "System Aliases" give some Alias Name, let's call it "SAP_R/3"
15) Now that System is created we have to create a iView which will display the given Transaction Code.
16) Go To "Content Administration".
17) Go To "Portal Content".
18) Go to Portal Content (Right Side Panel), open that folder
19) Right Click on Portal Content, a Panel is displayed select "New" -> iView
20) Select iView template, click next
21) Select "SAP Transaction iView" from the list of templates available. Click next.
22) Give the iView name and iView ID. Incase you want to give any brief notes about the iView then give it in "Description" field. Click next
23) Select "SAP GUI for HTML" radio button. Click next
24) Now select the system which you have create "SAP_R/3", give some Transaction Code, say SE12 (Dictionary Display). Click next and Finish.
25) Now Preview the iView
26) You will see a new Window where in SE12 Dictionary Display window is displayed.
Regards,
Senthil K. -
BBPGETVD throwing an error -Backend system with release 701 are not support
Experts,
After changing the Backend connection from R3 4.6c to ECC6 sysem in our BBPCRM4.0,
the transaction "BBPGETVD" is not working, which is throwing an error as
"Backend system with release 701 are not supported".
Already we have applied some of the notes (822883 &862290)
Thanks
AhamedAre you able to replicate other data like plants, product categories from the same backend system or are you facing the same error?
Also please check the logical system and see if they are assigned to the client correctly. (in SPRO settings)
Thanks,
Prashanth -
Backend System with Release 701 are not supported
SRM 5.0
Extended Classic Scenario
CCM 2.0
When updating the vendors in SRM system using TC - BBPUPDVD getting the below error message :-
Backend System with Release 701 are not supported
Have checked in table - BBP_BACKEND_DEST, the backend entry is properly maintained.
Can any one advice.
Regards,
Jayoti
Edited by: SAP jayoti on Dec 7, 2010 1:11 PMThe problem is resolved for vendor relication after applying the below notes 1313972 and 1372175.
ECC sandbox seems to be in 701 release. When the backend system ECC is in release 701, vendor replication fails with the error message that 'Backend system release 701 not supported'. We need to apply notes 1313972 and 1372175 to fix this issue. I have applied them in Sandbox and the issue is resolved now. -
Multiple ESS's in one Portal connected to different backend systems?
Hi,
We have two backend systems installed.
We have one portal.
We want to create a second copy of the ESS Portal content connected to the the second backend.
Datawise this is not a problem.
But what about the JCo's and the Homepage Framework?
The WebDympro application seems to look for two specific JCo (for example SAP_R3_HumanResources and ...MetaData) and then both copies of ESS want to use this. Is it not possible to have each copy of ESS use it own JCo's and connect to its own backend system for the Homepage Frameworks?
Thanks,
AdriaanAdriaan,
Its NOT possible to even talk to different clients in same backend system because you cannot duplicate the JCos and while creating them you need to specify the system and client details.
Also it uses a system alias which also has to be unique.
Per my knowledge one portal instance can talk to only backend client and to talk to another backend / client you will need to create a new instance within the Portal.
This [help|http://help.sap.com/saphelp_nw2004s/helpdata/en/82/76a2406546ba15e10000000a1550b0/frameset.htm] talks sometihng on multiple backend support. I am not much aware about it but see if it helps you.
Chintan -
BBPGETVD - error:backend systems with release 700 are not supported
Hi,
When I am trying to replicate vendor data from EEC to crm 4.0 via BBPGETVD.
I get the error message"backend systems with release 700 are not supported"
Is anyone have Idea what is wrong? and how can fix it?
Thanks,
RachelYossi,
I believe that standard transaction does not work with ECC 6.0. The standard response would be to upgrade your CRM system to 5.0 so that you can download vendors from ECC 6.0.
Bascially the vendor replication programs in CRM below 5.0 aren't really that reliable for delta downloads(one error will cause an entire load to fail). So you probably at best should copy the SAP standards to generate custom load programs as a starting point.
It is not too difficult and overcomes some of the restrictions that SAP puts in place(i.e. you can only use one number range for vendors downloaded, etc.). This is definitely one of the weak points of CRM 4.0 that was fixed in CRM 5.0.
If you have more questions on this let me know.
Take care,
Stephen -
'Backend systems with Release 701 are not supported'
while BBPGETVD transaction is run below error is seen,
'Backend systems with Release 701 are not supported'
Please help to resolve it.Hi
What is your backend system ECC version?
What is the configuaration in Define back end system?
Note 1313972 - BBPGETVD: Backend system latest release not supported
br
muthu -
"Backend systems with Release 701 are not supported " - ECC 6.0 to SRM 5.0
Hi ,
I have 2 doubts .
1. We are getting Error "Backend systems with Release 701 are not supported " while replicating vendors from ECC 6.0 backend system to SRM 5.0 system.
There are some notes on simillar topic but are not for SRM 5.0 ,suggested on SDN. an anyone please suggest what need to be done for the same.
2. Can we replicate Vendor Master Data with Contact Person from SRM to ECC system ? if yes, How ?
Regards
Narendraanswer 1:-
Note 1372175 - BBP_VENDOR_GET_DATA_JOB "Back-End Systems Not Supported"
On recent upgrade of the ECC back-end system to release '701' the program BBP_VENDOR_GET_DATA_JOB is getting errored out. If you are using SRM 5.0 , SRM_SERVER 550 with ECC backend Release 701 you encounter the above reported problem
Other terms
Vendor Replication Job, Release 701, Backend not supported, BBP_VENDOR_GET_DATA_JOB
Reason and Prerequisites
The program does not consider the release 701
remote_release EQ '700' OR remote_release EQ '701'.
OR
bbp_vendor_get_data - DEBUG what ois the remote_release 700 or 701?
Muhtu -
How many deferent ERP systems could we connect to one SRM system at the sa
Hi friends!
Could you tell me please, how many deferent ERP systems could we connect to one SRM system at the same time?
Thanks!Hi
I worked one srm three backend. But the relationis 1 to many . so you can config many backend system.
What are the problmes you are facing ?
Regards,
Satish Gopal -
[HP Expert Day] "You are not able to restore this system with the media"
Welcome to HP Experts day!
I've got a long-standing problem since last year. Let's see if you can solve this!
I'll get straight to the point :
I am unable to perform recovery on my system. This is the error message :
It's a USB recovery media created with the HP recovery media utility on the same laptop. Tested to work correctly before I sent it for RMA on my SSD. It initially was running on a micron SSD. When I got it back, it was a samsung SSD instead, according to some benchmark results.
Laptop : HP Envy Spectre XT 13-2018TU
P.S I've already opened another thread on this last year.
http://h30434.www3.hp.com/t5/Notebook-Recovery/Unable-to-boot-from-USB-recovery-media/m-p/2197929#M1...
But they were stumped.I had this exact same issue on a Spectre XT Pro Ultrabook.
The original SSD failed and I was sent a replacement, was fortunate enough to be able to create a Recovery USB stick using the wizard in Windows. When booting from USB I received the message "You are not able to restore this system with the media".
SOLUTION: You must NOT use the Recovery USB stick in any USB3.0 port (labelled SS). Using another USB port prevented this exact error message from appearing and I was able to complete the system restore process.
I hope this helps someone, I signed up and posted here especially for this reason! -
hello! My iMac frozed and I had to switch the electricty supply off and on in order to start again the system, with the problem that the screen looks wierd, I tried to calibrate it... doesnt works any suggestion?
Dear Paul, thank you very much for your time and answer, I followed those steps, somehow it helped the performance of my Imac, is faster now, but the screen issue about the very High contrast colours is still there. Since I am a photographer I am very depending on the screen calibration. I am worried that I came to damage the video card when I shut down the computer from the swicth when It was frozed.
-
I have 3 systems with the same issue (BSDOD) Event ID 41
I have 3 systems with the same issue that 1 to 4 times a day it crashes. This is on a VM complex running Win2K8 SR2.
I say many Symbol search path issues and fixed that on the system that can see internet (others are behind BSO Firewall)
Now I am down to the last issue with this first server W2K8.
If anyone cal help me it would really make my day...............
************* Symbol Path validation summary **************
Response Time (ms) Location
OK
C:\Windows\Minidump
0: kd> !analyze -v
* Bugcheck Analysis
DRIVER_IRQL_NOT_LESS_OR_EQUAL (d1)
An attempt was made to access a pageable (or completely invalid) address at an
interrupt request level (IRQL) that is too high. This is usually
caused by drivers using improper addresses.
If kernel debugger is available get stack backtrace.
Arguments:
Arg1: fffffa7f0ee7a410, memory referenced
Arg2: 0000000000000002, IRQL
Arg3: 0000000000000000, value 0 = read operation, 1 = write operation
Arg4: fffff88000e0b9ec, address which referenced memory
Debugging Details:
READ_ADDRESS: fffffa7f0ee7a410
CURRENT_IRQL: 2
FAULTING_IP:
NETIO!FreeMatchBufListInternal+1c
fffff880`00e0b9ec 488b5910 mov rbx,qword ptr [rcx+10h]
DEFAULT_BUCKET_ID: WIN7_DRIVER_FAULT
BUGCHECK_STR: 0xD1
PROCESS_NAME: System
ANALYSIS_VERSION: 6.3.9600.17237 (debuggers(dbg).140716-0327) amd64fre
TRAP_FRAME: fffff880021d8990 -- (.trap 0xfffff880021d8990)
NOTE: The trap frame does not contain all registers.
Some register values may be zeroed or incorrect.
rax=0000000000000000 rbx=0000000000000000 rcx=fffffa7f0ee7a400
rdx=0000000000000002 rsi=0000000000000000 rdi=0000000000000000
rip=fffff88000e0b9ec rsp=fffff880021d8b20 rbp=fffffa800cd199b8
r8=00000000000017e8 r9=00000000000000d0 r10=fffff80001603000
r11=0000000000000099 r12=0000000000000000 r13=0000000000000000
r14=0000000000000000 r15=0000000000000000
iopl=0 nv up ei ng nz na po nc
NETIO!FreeMatchBufListInternal+0x1c:
fffff880`00e0b9ec 488b5910 mov rbx,qword ptr [rcx+10h] ds:fffffa7f`0ee7a410=????????????????
Resetting default scope
LAST_CONTROL_TRANSFER: from fffff80001678169 to fffff80001678bc0
STACK_TEXT:
fffff880`021d8848 fffff800`01678169 : 00000000`0000000a fffffa7f`0ee7a410 00000000`00000002 00000000`00000000 : nt!KeBugCheckEx
fffff880`021d8850 fffff800`01676de0 : fffffa80`0d6cdc50 fffff880`010d8ba0 00000000`00000000 fffffa80`0ec7a170 : nt!KiBugCheckDispatch+0x69
fffff880`021d8990 fffff880`00e0b9ec : fffffa80`0f173cf0 fffffa80`0cd199b8 00000000`48706657 fffffa80`0cd199b8 : nt!KiPageFault+0x260
fffff880`021d8b20 fffff880`00e150f3 : fffffa80`0ec7a170 fffffa80`0cd199b8 00000000`00000011 fffffa80`0cd199b8 : NETIO!FreeMatchBufListInternal+0x1c
fffff880`021d8b50 fffff880`00e13f9d : fffffa80`0ec7a190 00000000`00000000 fffff880`021d8c30 fffff880`00e9273f : NETIO!FreeCacheEntry+0xa3
fffff880`021d8b90 fffff880`00e15176 : fffff880`021d8c30 00000000`00000000 fffffa80`0cd82660 fffffa80`0cd199b8 : NETIO!FreeSomeCacheBucketEntries+0x6d
fffff880`021d8be0 fffff880`00e1e221 : 00000000`0000000c fffffa80`0cd82660 fffffa80`0c020004 fffffa80`0cd82660 : NETIO!FreeSomeCacheEntries+0x36
fffff880`021d8c10 fffff880`00e073de : fffffa80`0f000003 fffffa80`0f173cf0 fffffa80`0cd82660 fffffa80`0f173cf0 : NETIO! ?? ::FNODOBFM::`string'+0x7a46
fffff880`021d8c50 fffff800`0196fc93 : 00000000`00000001 00000000`00000001 fffffa80`0f173cf0 fffffa80`0cd82660 : NETIO!TickWorker+0xe
fffff880`021d8c80 fffff800`01682261 : fffff800`0181e200 fffff800`0196fc01 fffffa80`0cd82600 fffff800`0181e2d8 : nt!IopProcessWorkItem+0x23
fffff880`021d8cb0 fffff800`0191473a : 498b4809`75c43b41 fffffa80`0cd82660 00000000`00000080 fffffa80`0cd78740 : nt!ExpWorkerThread+0x111
fffff880`021d8d40 fffff800`016698e6 : fffff880`0205d180 fffffa80`0cd82660 fffffa80`0cd83660 ffffff33`e9ed75cd : nt!PspSystemThreadStartup+0x5a
fffff880`021d8d80 00000000`00000000 : fffff880`021d9000 fffff880`021d3000 fffff880`021d89e0 00000000`00000000 : nt!KxStartSystemThread+0x16
STACK_COMMAND: kb
FOLLOWUP_IP:
NETIO!FreeMatchBufListInternal+1c
fffff880`00e0b9ec 488b5910 mov rbx,qword ptr [rcx+10h]
SYMBOL_STACK_INDEX: 3
SYMBOL_NAME: NETIO!FreeMatchBufListInternal+1c
FOLLOWUP_NAME: MachineOwner
MODULE_NAME: NETIO
IMAGE_NAME: NETIO.SYS
DEBUG_FLR_IMAGE_TIMESTAMP: 5294760d
FAILURE_BUCKET_ID: X64_0xD1_NETIO!FreeMatchBufListInternal+1c
BUCKET_ID: X64_0xD1_NETIO!FreeMatchBufListInternal+1c
ANALYSIS_SOURCE: KM
FAILURE_ID_HASH_STRING: km:x64_0xd1_netio!freematchbuflistinternal+1c
FAILURE_ID_HASH: {4f4b2cba-a197-a425-b97a-8f7cbfbac87f}
Followup: MachineOwnerGWD
This does not surprise me at all. These were/are related to your Symantec. IMHO it is bloatware and after doing 10,000+ BSODS I have seem it more than any other malware app I would remove it and use MSE in its place
Symantec is a frequent cause of BSOD's.
I would remove and replace it with Microsoft Security Essentials AT LEAST TO TEST
http://us.norton.com/support/kb/web_view.jsp?wv_type=public_web&docurl=20080710133834EN
http://www.microsoft.com/security_essentials/
For Norton 360 use this http://symantec.pcperformancetools.com/norton-360-how-to-uninstall.html
Microsoft (R) Windows Debugger Version 6.3.9600.17237 AMD64
Copyright (c) Microsoft Corporation. All rights reserved.
Loading Dump File [C:\Users\Ken\Desktop\Minidump\102714-47923-01.dmp]
Mini Kernel Dump File: Only registers and stack trace are available
************* Symbol Path validation summary **************
Response Time (ms) Location
Deferred SRV*D:\symbols*http://msdl.microsoft.com/download/symbols
Symbol search path is: SRV*D:\symbols*http://msdl.microsoft.com/download/symbols
Executable search path is:
Windows 7 Kernel Version 7601 (Service Pack 1) MP (4 procs) Free x64
Product: Server, suite: Enterprise TerminalServer SingleUserTS
Built by: 7601.18526.amd64fre.win7sp1_gdr.140706-1506
Machine Name:
Kernel base = 0xfffff800`0165e000 PsLoadedModuleList = 0xfffff800`018a1890
Debug session time: Mon Oct 27 05:05:39.635 2014 (UTC - 4:00)
System Uptime: 1 days 4:50:11.507
Loading Kernel Symbols
Loading User Symbols
Loading unloaded module list
* Bugcheck Analysis *
Use !analyze -v to get detailed debugging information.
BugCheck C5, {8, 2, 1, fffff80001808147}
*** WARNING: Unable to verify timestamp for SYMEFA64.SYS
*** ERROR: Module load completed but symbols could not be loaded for SYMEFA64.SYS
Probably caused by : SYMEFA64.SYS ( SYMEFA64+27c5 )
Followup: MachineOwner
0: kd> !analyze -v
* Bugcheck Analysis *
DRIVER_CORRUPTED_EXPOOL (c5)
An attempt was made to access a pageable (or completely invalid) address at an
interrupt request level (IRQL) that is too high. This is
caused by drivers that have corrupted the system pool. Run the driver
verifier against any new (or suspect) drivers, and if that doesn't turn up
the culprit, then use gflags to enable special pool.
Arguments:
Arg1: 0000000000000008, memory referenced
Arg2: 0000000000000002, IRQL
Arg3: 0000000000000001, value 0 = read operation, 1 = write operation
Arg4: fffff80001808147, address which referenced memory
Debugging Details:
BUGCHECK_STR: 0xC5_2
CURRENT_IRQL: 2
FAULTING_IP:
nt!ExAllocatePoolWithTag+537
fffff800`01808147 48895808 mov qword ptr [rax+8],rbx
CUSTOMER_CRASH_COUNT: 1
DEFAULT_BUCKET_ID: WIN7_DRIVER_FAULT_SERVER
PROCESS_NAME: ccSvcHst.exe
ANALYSIS_VERSION: 6.3.9600.17237 (debuggers(dbg).140716-0327) amd64fre
TRAP_FRAME: fffff880069f9580 -- (.trap 0xfffff880069f9580)
NOTE: The trap frame does not contain all registers.
Some register values may be zeroed or incorrect.
rax=0000000000000000 rbx=0000000000000000 rcx=fffffa800f880f60
rdx=0000000000000000 rsi=0000000000000000 rdi=0000000000000000
rip=fffff80001808147 rsp=fffff880069f9710 rbp=0000000000001000
r8=0000000000000000 r9=fffff80001863770 r10=fffff80001863588
r11=0000000000000000 r12=0000000000000000 r13=0000000000000000
r14=0000000000000000 r15=0000000000000000
iopl=0 nv up ei pl zr na po nc
nt!ExAllocatePoolWithTag+0x537:
fffff800`01808147 48895808 mov qword ptr [rax+8],rbx ds:00000000`00000008=????????????????
Resetting default scope
LAST_CONTROL_TRANSFER: from fffff800016d3169 to fffff800016d3bc0
STACK_TEXT:
fffff880`069f9438 fffff800`016d3169 : 00000000`0000000a 00000000`00000008 00000000`00000002 00000000`00000001 : nt!KeBugCheckEx
fffff880`069f9440 fffff800`016d1de0 : fffff880`069f9690 fffffa80`0d157d80 fffff880`069f9500 fffff800`01863770 : nt!KiBugCheckDispatch+0x69
fffff880`069f9580 fffff800`01808147 : fffff8a0`078d3140 00000000`00000702 fffffa80`0f95c800 fffff8a0`078d33a8 : nt!KiPageFault+0x260
fffff880`069f9710 fffff880`016bf7c5 : fffff880`00000000 00000000`00000000 fffffa80`0ddc6530 fffff880`00000000 : nt!ExAllocatePoolWithTag+0x537
fffff880`069f9800 fffff880`00000000 : 00000000`00000000 fffffa80`0ddc6530 fffff880`00000000 00000000`00000000 : SYMEFA64+0x27c5
fffff880`069f9808 00000000`00000000 : fffffa80`0ddc6530 fffff880`00000000 00000000`00000000 fffff880`016bf514 : 0xfffff880`00000000
STACK_COMMAND: kb
FOLLOWUP_IP:
SYMEFA64+27c5
fffff880`016bf7c5 ?? ???
SYMBOL_STACK_INDEX: 4
SYMBOL_NAME: SYMEFA64+27c5
FOLLOWUP_NAME: MachineOwner
MODULE_NAME: SYMEFA64
IMAGE_NAME: SYMEFA64.SYS
DEBUG_FLR_IMAGE_TIMESTAMP: 530fcaf7
FAILURE_BUCKET_ID: X64_0xC5_2_SYMEFA64+27c5
BUCKET_ID: X64_0xC5_2_SYMEFA64+27c5
ANALYSIS_SOURCE: KM
FAILURE_ID_HASH_STRING: km:x64_0xc5_2_symefa64+27c5
FAILURE_ID_HASH: {c40fe135-4c88-ce5c-c7b0-361d3927c5c6}
Followup: MachineOwner
Wanikiya and Dyami--Team Zigzag -
Creation of multiple connectors if we have backend systems with multiple
Hi All,
If I have 5 backend systems with 2 clients each.
Do I need to create UWL connector for each client.
Regards
SuneelHi,
You have to create a connector for each system alias. So if you have a backend with 2 clients and you want to retrieve work items from both clients you will have to create 2 systems (and 2 aliases) and 2 UWL connectors.
Regards,
Pierre
Maybe you are looking for
-
Menu/Toolbar Display Corruption Upon Resizing Window
We're experiencing an issue with one of our workstations where when the Adobe Reader X (10.1.3) window is resized, the Menu/Toolbar displays become corrupt and garbled on the screen (see the attached picture). The Toolbar appears on the top, the fram
-
How to change the grayed field font in apex
Hi, I need to change the grayed field item font ... ie i need to make disabled item value to be bright to achieve this what i have to do ... Regards, pavan
-
Re-arrange the flat file out put in APD
Hi Guys, I am loading data in APD,soruce is Query and target is Flat file.i want to re-arrange the out put file. Let me know what are the possible ways to re-arrange the columns in the out put flat file. Regards, Jayapal
-
JUNIT: how to desgin this test so there would be one INSERT to db?
Hi there, How should I design this test: I would like to upload a files system and do INSERT to the db. once I have the info in the db I would like to READ it and check against some other files. so I have something like this: doInsert(); doRead(); te
-
Will this wipeout my data.Can it be avoided?
Ok i updated my touch to 3.1.3 and i want to downgrade it back to 3.1.2. Is there a way that it wont wipeout my data? if so how? please respond.