Connecting to a Sun StorEdge 3310

Hello all,
in our warehouse I've found a Sun StorEdge 3310. I want to try to use it but I do not have any kind of usefull serial cable. Also StorEdge has a LAN port but I'm not able to find a mac address to force ARP table and telnet it.
Any hint to get my storage accessible?
Thanks
Stefano
http://www.stefanocislaghi.it

Please have a look at the installation document http://docs.sun.com/app/docs/doc/816-7290-19 and feel free to get back here if you still have questions.

Similar Messages

  • Sun Storedge 3310

    I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2? If ther is could you tell me how. I know how to do it on server 2003 but 2012 r2 is much different.

    Hi,
    I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2?
    Since we are not familiar with the product you have mentioned, I would suggest you contact corresponding vendor support to get more specific and accurate response.
    Thank you for your understanding and support.
    Best Regards,
    Amy
    Please remember to mark the replies as answers if they help and un-mark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Veritas Volume manager 4.0 with Sun StorEdge 3310 D

    I am running into a problem. The vxconfigd deamon always dump core when rebooting.
    Our environment is listed below.
    OS environemt.
         SunOS server1 5.8 Generic_117350-43 sun4u sparc SUNW,Sun-Fire-V240
    Software installed.
         Sun Cluster 3.0
         Veritas Volume Manager 4.0 MP2.
    Disk Array associated.
         Sun StorEdge 3310 D.
    I looked up veritas.com and find Array Support Library (ASL) for Sun StorEdge 3xxx Series is recommended. But I didn't find this library is running on this server.
    Please refer to this following link
    http://support.veritas.com/docs/277923
    As our system is one of critical systems and I'd like to confirm that I can follow up this procedure without doing harm things to our system.
    Jeff

    No problem Jeff :)
    I took a look at the Veritas doc and you're right it does seem to cover everthing.
    Has the vxconfigd core dumped since the start? ie from the moment it was installed?
    I have installed VXVM 4.0 with Solaris 8 but without the ASL and this worked ok, I know that's not much help to you but I am not sure the ASL will help. Mind you I have not installed it with Sun Cluster 3.0.

  • Sun storedge 3310 fw 4.1.5f MIB ?

    Hi does anybody know where can I find the MIB snmp file for Sun storedge 3310 fw version 4.1.5.f ?
    Thanks

    Nevermind the last posts, I forgot to install the 32 bit drivers of ultra 3 card.
    Anyway thanks to anyone who might have thought about this.
    Orlando

  • Multi-initated LUNS on Sun StorEdge 3310

    I recently received two Sun V20Zs and a StorEdge 3310, and I am asked to cluster these two machines with the 3310 as shared storage. 3310 came with two raid controllers.
    My question is, could I create multi-initiaged LUNs and have these LUNs mapped by the V20Z. Reason behind having the multi-imitated LUNs is it will facilitate fail-over in case a one of the V20Z are unavailable.
    V20Zs are running Fedora Core 3.
    Thanks for your help.

    A good output that would give you a hint of a problem is iostat -En
    This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
    If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues.

  • Disk error message on Sun StorEdge 3310.

    Hi guys,
    Does anyone see the following error message in the /var/adm/messages? Should I have to replace this faulty disk?
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.warning] WARNING: /pci@1d,700000/sc
    si@1/sd@5,0 (sd36):Mar 6 11:06:21 balrog Error for Command: write(10) Error Level:Retryable
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Requested Block: 5491072 Error Block: 5491079
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Vendor: SEAGATE
    Serial Number: 0447B9LRDV
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Sense Key: Hardware Error
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] ASC: 0x32 (no defect spare location available), ASCQ: 0x0, FRU: 0x4
    Looking forward to your comments.
    Jeff.

    A good output that would give you a hint of a problem is iostat -En
    This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
    If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues.

  • Storedge 3310 and format

    hi,
    i have the following problem:
    a storedge 3310 with raid controller. i have partitioned the volume ( which consists of 6 raid 1 logical drives) into 4 partions and assigned luns to these partitions.
    probe-scsi-all shows the following:
    /pci@1e,600000/pci@2/scsi@4
    Target 0
    Unit 0 Disk SUN StorEdge 3310 0325
    Unit 1 Disk SUN StorEdge 3310 0325
    Unit 2 Disk SUN StorEdge 3310 0325
    Unit 3 Disk SUN StorEdge 3310 0325
    format shows only the first one:
    0. c0t0d0
    /pci@1c,600000/scsi@2/sd@0,0
    1. c0t1d0
    /pci@1c,600000/scsi@2/sd@1,0
    2. c2t0d0
    /pci@1e,600000/pci@2/scsi@4/sd@0,0
    where are the other three partitions?

    Hi there,
    I have a similar situation where I set up a SE 3310 connected to a Sunfire V210 running Solaris 10 GA.
    The SE 3310 was set up as 2 RAID 5 logical volumes, each
    with 5x72GB disk drives. I also map the hosts LUNS etc...
    At the V210, when I did the probe-scsi-all it sees both RAID5
    logical disks as StorEdge 3310 0325 (firmware 3.25)
    however when I boot up with the -rv option, it only sees one
    RAID5. Where is the other RAID 5 logical drive?
    I did update_drv -f sd, devfsadm; manually edit the sd.conf
    to add additional controllers and LUN's (c0,c1,c2 and up to
    32 LUN's for each controller, but I still do not see the other
    RAID5 logical drive. Where is it?
    Please help !!!
    Tony

  • Partition logical drive storedge 3310

    Hi
    I have Sun storedge 3310 version 413B, i create logical drive in Raid 5 configuration:
    LD LD-ID Size Assigned Type Disks Spare Failed Status
    ld0 68EB1906 272.46GB Primary RAID5 5 1 0 Good
    and i need create 16 partitions on it, but i can create only 7 partitions:
    * partitions
    LD/LV ID-Partition Size
    ld0-00 68EB1906-00 14.00GB
    ld0-01 68EB1906-01 14.00GB
    ld0-02 68EB1906-02 14.00GB
    ld0-03 68EB1906-03 14.00GB
    ld0-04 68EB1906-04 14.00GB
    ld0-05 68EB1906-05 14.00GB
    ld0-06 68EB1906-06 14.00GB
    ld0-07 68EB1906-07 14.00GB
    How i can create other eight partitions on ld0; i need create this configuration:
    ld0-00 68EB1906-00 14.00GB
    ld0-01 68EB1906-01 14.00GB
    ld0-02 68EB1906-02 14.00GB
    ld0-03 68EB1906-03 14.00GB
    ld0-04 68EB1906-04 14.00GB
    ld0-05 68EB1906-05 14.00GB
    ld0-06 68EB1906-06 14.00GB
    ld0-07 68EB1906-07 14.00GB
    ld0-08 68EB1906-08 14.00GB
    ld0-09 68EB1906-09 14.00GB
    ld0-0a 68EB1906-0A 14.00GB
    ld0-0b 68EB1906-0B 14.00GB
    ld0-0c 68EB1906-0C 20.00GB
    ld0-0d 68EB1906-0D 20.00GB
    ld0-0e 68EB1906-0E 20.00GB
    ld0-0f 68EB1906-0F 20.00GB
    ld0-10 68EB1906-10 24.46GB
    any idea?....thanks

    If you are using lun mapping to create your partitions, (done by using telnet to the array and then selecting "View and Edit Host Luns") you have to tell the array the maximum numbers of luns you can create. Some systems will only let you create one by default and you can't make any changes to the size of the lun you are trying to present to your host. There is an option when you telnet to the box in the controller area for the maximum number of luns you can create. Luns in this case are partitions.
    If you are not trying to partition your logical drive by using lun mapping, I don't know what your problem is.
    Stephen

  • Two servers with redundant connections for Sun StorEdge 3320 SCSI arrays

    Hello All,
    I read in the "Sun StorEdge 3000 Family Installation, Operation and Service Manual" that it's possible to setup "two servers with redundant connections" but I never see a detailed schema to do this. I read also the "Best Pratices Guide" but this case is not mentioned. Is it really possible ?
    My objective is to split a Sun StoreEdge 3320 SCSI array between two hosts with dual redundant scsi connection.
    Thanks in advance for your answers.
    Francois.

    At first this sounded easy, but looking at the parts listing for the 3320 seems to indicate otherwise. They're listing different part numbers for the chassis and midplane...
    371-0105 chassis & midplane for JBOD
    371-0106 chassis & midplane for RAID array
    There are also different part numbers for the I/O boards....
    370-7655 RAID SCSI I/O module
    370-7713 JBOD SCSI I/O module
    I can see what the difference is between the I/O modules, but am unsure of what differences if any are in the chassis and midplane. Seems like there's more involved here than what it would be worth to try and make it work. Perhaps the cost of a second HBA would be the lesser of two evils..........

  • Sun StorEdge[TM] 3510/3310/3511

    Dear
    What does the "2(3)" mean in the show disks output under the channel ID (Ch) for Sun StorEdge[TM] 3310/3510/3511
    :)Thanks
    Mohammed Tanvir

    Hi
    2(3) means there are two channels configured for the storedge 2 and 3 or I should say that it is in redundant mode. And at present control is with 2nd channel.
    Regards

  • Sun storedge se 3310

    Hello all,
    I have created on a sun storedge se 3310 an RAID 5 array matrix with 4 disks (73 GB) for logical drive and a 5th disk (73 GB) for local spare. It seems that is taking a long time to be created and i can not see any activity on the servers leds.
    Can anyone tell me how long it should take until the array will be finished?
    Thanks

    For SE3310 RAID 5 with 4HDD(73GB) you have to wait for about 1.5hrs to 2hrs. new LD be completely initialized, then after that you can perform lun mapping.

  • StorEdge 3310 RAID hung.

    During the billing run on a Sun Fire V440, the attached 3310 hung. Reboots of the server did nothing to improve the situation, but once the RAID was powercycled everything was alright again.
    sccli version 2.1.1
    built 2005.09.16.23.10
    build 1 for solaris-sparc
    Vendor: SUN
    Product: StorEdge 3310
    Revision: 0325
    Peripheral Device Type: 0x0
    NVRAM Defaults: 325S 3310 v1.37
    Bootrecord version: 1.31G
    Serial Number: 07CB61
    There are no "event" entries for this trouble listed in sscli, and everything comes up green. The only errors we received at the time were that of SCSI errors:
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.warning] WARNING: /pci@1f,700
    000/scsi@2,1/sd@0,0 (sd16):
    Aug 10 10:49:30 InfranetDB01 Error for Command: write(10) Error
    Level: Retryable
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Requested Block:
    289557696 Error Block: 289557696
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Vendor: SUN
    Serial Number: 29C8306F-00
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Sense Key: Unit
    Attention
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] ASC: 0x29 (power
    on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x0
    Aug 10 11:01:12 InfranetDB01 scsi: [ID 107833 kern.notice] /pci@1f,700000/scsi@2
    ,1 (mpt1):
    Aug 10 11:01:12 InfranetDB01 got external SCSI bus reset.
    Aug 10 11:01:12 InfranetDB01 scsi: [ID 365881 kern.info] /pci@1f,700000/scsi@2,1
    (mpt1):
    Aug 10 11:01:12 InfranetDB01 Log info 11030000 received for target 0.
    Aug 10 11:01:12 InfranetDB01 scsi_status=0, ioc_status=804b, scsi_state=8
    Aug 10 11:01:12 InfranetDB01 scsi: [ID 107833 kern.notice] /pci@1f,700000/scsi@2
    ,1 (mpt1):
    Aug 10 11:01:12 InfranetDB01 got external SCSI bus reset.
    [repeat]
    The question is whether or not to upgrade the firmware. Since the current firmware is so old (version 3.x) there seems to be special instructions to bring it to 4.x, and eventually 4.15G. Which would include OS patches as well. (117171-12).
    Or, just carry on, since this has only happened once (during the last billing run) in the last 9 runs/months.

    What is the difference between the host/drive channel? Besides the fact that they are their for connecting to disk drive or to host. Because lets say I connect the first RAID controller to the second one, host-to-host configuration from one RAID to another, will the host see this transparently?
    By the way, I tried the JBOD method you mention so basically just connect one of the RAID unit to the other one just as a JBOD and the RAID controller can see the disks on a difference channel but only half of the disk because the RAID I/O actually have internal conneciton to half of the disk, while the other half is jumper.

  • Partition Storedge 3310

    Hello All,
    My first connection on this forum & I would need your help.
    I have to configure a Storedge 3310 (6 disks 72Gb).
    Already created:
    1 Logical Drive: 5 disks in Raid 5 + 1 Spare
    Size of the drive: 279GB.
    I need to create 11 partitions (10*12GB + 1*159GB), but apparently, I can create only 8 partitions (from 0 to 7).
    Could you help me? I don't know how to do.
    I already read this topic: http://forum.java.sun.com/thread.jspa?forumID=831&threadID=5098175
    But the answer is not really clear (for me...)
    Thx.
    Eric
    Message was edited by:
    Eric_MdZ

    I had to do something similar on site today, I believe (although have not tried it) that you alter the number of partitions to create on the 3320, however an alternative way of partitioning the Logical Drive is to let Solaris do it, by that I mean LVM ( formly known as disksuite). Bring the logical drive into solaris and create one large partition. Bring that single partition into LVM and then use "soft partitioning" to break it up. I have done this before and it works fine, its just another way of doing the same job albeit on the host and not on the Array.

  • Password on storedge 3310

    I have a old storedge 3310. There is a password on there that I do not have. I'm running ubuntu 14.04 on the server. I do not have any software the came with storedge 3310. So how do go about change the password? I know that if I had all the sun software this would not be a problem but, I have not been able to find any. I'm using a serial cable to connect the 2 servers together.
    Thanks

    Do you know the current password on the 6120?
    If not, then I'm afraid you'll need a service engineer and downtime on the array to change it.
    If you do know it, then you just telnet to the 6120; log in with the username 'root' and the current password and then issue the 'passwd' command.
    HTH,
    --A.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

  • Solstice backup 6.1 hang when invoking the autochanger "SUN Storedge L8 "

    My company have a SUN Storedge L8 attached to a SUN Solaris 9 (SPARC) while I can only do a tar to the /dev/rmt/0, whenever I tried to interact with the jukebox with the solstice backup, the program hang definitely.
    grep '/usr/kernel/drv/lus' /var/sadm/install/contents
    /usr/kernel/drv/lus f none 0555 root bin 34624 12073 993189557 SUNWsbus2
    /usr/kernel/drv/lus.conf f none 0444 root bin 3754 45438 993190441 SUNWsbus2
    /usr/kernel/drv/lus32 f none 0555 root bin 33444 4422 993213667 SUNWsbus2
    pkginfo -l SUNWsbus2
    PKGINST: SUNWsbus2
    NAME: Solstice Backup (Backup/Recover) Device Drivers
    CATEGORY: system
    ARCH: sparc
    VERSION: 6.1,REV=Build.186
    BASEDIR: /
    VENDOR: Sun Microsystems, Inc.
    PSTAMP: gelato010622054128
    INSTDATE: Apr 08 2003 13:25
    STATUS: completely installed
    FILES: 48 installed pathnames
    44 executables
    37896 blocks used (approx)
    this machine has installed the solstice backup manager
    pkginfo | grep -i Solstice
    system SUNWmibii Solstice Enterprise Agents 1.0.3 SNMP daemon
    system SUNWsacom Solstice Enterprise Agents 1.0.3 files for root file system
    system SUNWsadmi Solstice Enterprise Agents 1.0.3 Desktop Management Interface
    system SUNWsadml Solstice Launcher.
    system SUNWsadmx Solstice Enterprise Agents 1.0.3 Desktop Management Interface Libraries (64-bit)
    system SUNWsasnm Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol
    system SUNWsasnx Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol Libraries (64-bit)
    application SUNWsbuc Solstice Backup (Backup/Recover) Client
    application SUNWsbum Solstice Backup (Backup/Recover) Man
    application SUNWsbun Solstice Backup (Backup/Recover) Storage Node
    application SUNWsbus1 Solstice Backup (Backup/Recover) Server
    system SUNWsbus2 Solstice Backup (Backup/Recover) Device Drivers
    under the server->registration, I found that the registration contains :-
    Autochanger Module, 9 slots/9
    ClientPaks for Windows/1
    Networker for UNIX, Workgroup edition (8 clients per server)1 server
    Networker Module for Oracl/1
    BTW, inquire shows:-
    /etc/LGTOuscsi/inquire
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    where cfgadm -alv shows:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    nsrjb shows
    Jukebox L8:
    slot volume pool volume id recyclable
    1: dwbak.inc.day0.wk0.001* 2481680129
    2: dwbak.inc.day0.wk0.002 DW Incremental 2481704705 no
    3: dwbak.inc.day0.wk0.003 DW Incremental 2481729793 no
    4: -* -
    5: dwbak.inc.day0.wk0.005 DW Incremental 2481779201 no
    6: dwbak.inc.day0.wk0.006 DW Incremental 2481804289 no
    7: dwbak.inc.day0.wk0.007 DW Incremental 2481829889 no
    8: dwbak.inc.day0.wk0.008 DW Incremental 2481854209 no
    *not registered in the NetWorker media data base
    drive 1 (/dev/rmt/0cbn) slot 5: dwbak.inc.day0.wk0.005
    nsrjb -HE hang indefinitly, so does nsrjb -HHE. devfsadm -c tape also hang while simply devfsadm can run without problem and cfgadm -alv c3 provide the following:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    nsjrb result should be past history, coz I am doing tar and manually changing the slot for quite some time already. Now I unconnect the cable and run devfsadm and then cfgadm -alv shows
    cfgadm -alv
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    and inquire still shows
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    and then I reconnect the cable I saw a lot of error message in dmesg:-
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:51:30 server scsi: [ID 107833 kern.notice] /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:30 server Failed to Get Features
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server ISP: Firmware cmd timeout
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server Fatal error, resetting interface, flg 1
    and devfsadm hang. So I double check the past demsg and found a lot of similar SCSI error message as below:-
    Jun 19 13:43:12 server probe request for LUN 0 denied: max LUN -1
    Jun 19 13:43:12 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@5 (qus1):
    Is that represent a hardware failure either on the jukebox or the SCSI controller? Or it is indeed a software corruption that can only be solved by reinstallation? But unfortunately I don't have the media on hand.
    PS.a more details can be found under expert exchange thru the links below:-
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23413012.html#a21749881
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23478147.html

    My company have a SUN Storedge L8 attached to a SUN Solaris 9 (SPARC) while I can only do a tar to the /dev/rmt/0, whenever I tried to interact with the jukebox with the solstice backup, the program hang definitely.
    grep '/usr/kernel/drv/lus' /var/sadm/install/contents
    /usr/kernel/drv/lus f none 0555 root bin 34624 12073 993189557 SUNWsbus2
    /usr/kernel/drv/lus.conf f none 0444 root bin 3754 45438 993190441 SUNWsbus2
    /usr/kernel/drv/lus32 f none 0555 root bin 33444 4422 993213667 SUNWsbus2
    pkginfo -l SUNWsbus2
    PKGINST: SUNWsbus2
    NAME: Solstice Backup (Backup/Recover) Device Drivers
    CATEGORY: system
    ARCH: sparc
    VERSION: 6.1,REV=Build.186
    BASEDIR: /
    VENDOR: Sun Microsystems, Inc.
    PSTAMP: gelato010622054128
    INSTDATE: Apr 08 2003 13:25
    STATUS: completely installed
    FILES: 48 installed pathnames
    44 executables
    37896 blocks used (approx)
    this machine has installed the solstice backup manager
    pkginfo | grep -i Solstice
    system SUNWmibii Solstice Enterprise Agents 1.0.3 SNMP daemon
    system SUNWsacom Solstice Enterprise Agents 1.0.3 files for root file system
    system SUNWsadmi Solstice Enterprise Agents 1.0.3 Desktop Management Interface
    system SUNWsadml Solstice Launcher.
    system SUNWsadmx Solstice Enterprise Agents 1.0.3 Desktop Management Interface Libraries (64-bit)
    system SUNWsasnm Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol
    system SUNWsasnx Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol Libraries (64-bit)
    application SUNWsbuc Solstice Backup (Backup/Recover) Client
    application SUNWsbum Solstice Backup (Backup/Recover) Man
    application SUNWsbun Solstice Backup (Backup/Recover) Storage Node
    application SUNWsbus1 Solstice Backup (Backup/Recover) Server
    system SUNWsbus2 Solstice Backup (Backup/Recover) Device Drivers
    under the server->registration, I found that the registration contains :-
    Autochanger Module, 9 slots/9
    ClientPaks for Windows/1
    Networker for UNIX, Workgroup edition (8 clients per server)1 server
    Networker Module for Oracl/1
    BTW, inquire shows:-
    /etc/LGTOuscsi/inquire
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    where cfgadm -alv shows:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    nsrjb shows
    Jukebox L8:
    slot volume pool volume id recyclable
    1: dwbak.inc.day0.wk0.001* 2481680129
    2: dwbak.inc.day0.wk0.002 DW Incremental 2481704705 no
    3: dwbak.inc.day0.wk0.003 DW Incremental 2481729793 no
    4: -* -
    5: dwbak.inc.day0.wk0.005 DW Incremental 2481779201 no
    6: dwbak.inc.day0.wk0.006 DW Incremental 2481804289 no
    7: dwbak.inc.day0.wk0.007 DW Incremental 2481829889 no
    8: dwbak.inc.day0.wk0.008 DW Incremental 2481854209 no
    *not registered in the NetWorker media data base
    drive 1 (/dev/rmt/0cbn) slot 5: dwbak.inc.day0.wk0.005
    nsrjb -HE hang indefinitly, so does nsrjb -HHE. devfsadm -c tape also hang while simply devfsadm can run without problem and cfgadm -alv c3 provide the following:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    nsjrb result should be past history, coz I am doing tar and manually changing the slot for quite some time already. Now I unconnect the cable and run devfsadm and then cfgadm -alv shows
    cfgadm -alv
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    and inquire still shows
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    and then I reconnect the cable I saw a lot of error message in dmesg:-
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:51:30 server scsi: [ID 107833 kern.notice] /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:30 server Failed to Get Features
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server ISP: Firmware cmd timeout
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server Fatal error, resetting interface, flg 1
    and devfsadm hang. So I double check the past demsg and found a lot of similar SCSI error message as below:-
    Jun 19 13:43:12 server probe request for LUN 0 denied: max LUN -1
    Jun 19 13:43:12 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@5 (qus1):
    Is that represent a hardware failure either on the jukebox or the SCSI controller? Or it is indeed a software corruption that can only be solved by reinstallation? But unfortunately I don't have the media on hand.
    PS.a more details can be found under expert exchange thru the links below:-
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23413012.html#a21749881
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23478147.html

Maybe you are looking for

  • J2I9 program J_1I57AE Proforma Register ecs and sh ecs issue

    Hi All, I have a requirement to display the opening and closing balnace of ECS and SH ECS along with the opening and closing CENVAT balances for input and capital goods. Can anyone tell me what logic can be used to get ECS and SH ECS. As per my under

  • SAT A305 will not boot up

    If I press power on, the laptop will turn on and load the opening Toshiba screen, but will then stay at a black screen with a flashing underscore in the top left corner. It never gets to the Windows page. From the opening Toshiba screen, I can access

  • Mesh APs 1522 b/g channel issue

    Hi, We have deployed a Mesh network using 1522 APs. Everythings works fine for the A radio, but not for the B/G radio too. We have configured the b/g radios to automatically select their channel, (Global mode), using channels 1,6,11 through DCA. All

  • While calling method exception:-com.ibm.ejs.container.UncheckedException: ;

    frnds! while calling a method from statelesssession bean the exception is thrown:-- Error 500 An error has occured while processing request:http://192.168.1.61/MyApp/TradeSession/TradeClient.jsp Message: Server caught unhandled exception from servlet

  • Sansa Fuze Problems

    Hello, I use Arch Linux i686, and when I try to plug in my 4GB Sansa Fuze, it fails to be detected by Linux as a USB mass storage device, even when in MSC mode. Does anyone know how to fix this problem? Here is my dmesg | tail output: usb 3-1: device