Hi,
    I am trying out an exercise on receiving the data from the 54600B oscilloscope into LabVIEW Analog and Digital Modulations VIs. Currently, i am trying out on ASK modulation and i want to grab the signal/waveform from the scope and display in the ASK modulation exactly the same as ASK modulation graph. And this ASK modulation will be used as SubVIs,which can be seen from the attachment to have a clearer image on the work.Can anyone please help me??This is very important because it is my project work..Thanks Alot!
Attachments:
ASK modulation_modify2.zip ‏854 KB

Hi,
    yes, that's the graph i am talking about. I think you can see it the ranges and position beside the graph belong to it and have their 'default' setting of scales which is autoscale but i cannot see(or display another) the waveform in the graph when i run my exercise. So i have to set the scales manually instead of using the default scales. For a clearer explaination, eg. i set my scope and display a waveform i want, but when i run the exercise, not only the "signal generator information graph" did not display the desired waveform i want in addition, it affect and change the waveform in the scope too (some time too big and scope hang for a few sec or other waveform). that's why i have to set the setting of the "signal generator information graph" manually but i don't know in order to set the value of those ranges and position,what factor or condition i must take into consideration. I did know can change the scale, thanks but i don't know how to set to a correct scales as i have failed for many times in displaying the waveform correctly both in scope and LabVIEW "signal generator information graph".

Similar Messages

  • Lost ActiveX connection with LabVIEW server

    I have called LabVIEW in TestStand and tried to execute the test cases .
    While executing I got the following error:  ( Lost ActiveX connection with LabVIEW server.
    The LabVIEW adapter will try to reconnect on the next execution attempt.-18001; An error occurred accessing the LabVIEW ActiveX automation server.).

    Same error.  Is anyone from NI going to bother commenting on this?  It's been >8 months...

  • Ethernet connection with labview using Modbus

    I want to communicate via  Ehternet connection with LabVIEW using modbus protocol, Just as RS232 (COM) coomunication wiht Modbus in Labview.
    mini

    See these threads.
    http://forums.ni.com/ni/board/message?board.id=170​&message.id=151337&view=by_date_ascending&page=1
    http://sine.ni.com/apps/we/niepd_web_display.displ​ay_epd4?p_guid=F1582737BACF5CA8E0340003BA7CCD71&p_​...

  • HP/Agilent Infiniium 54831B scope - how to connect with LabView 6.0 by LAN (TCP/IP)

    Dear,
    I'm looking inf. how to connect Agilent Infiniium 54831B scope with LabView 6.0 by LAN (TCP/IP).
    Thanks in advance.
    Regards,
    Z.Mrowka
    mailto:[email protected]

    Hello,
    If the instrument is capable of being controlled from its TCP/IP port, it will be possible to communicate with the instrument from LabVIEW using VISA.
    The VISA resource name input will need to be entered manually and is a little different from the normal Serial or GPIB format. The format is as follows:
    For SOCKET connections, this is just like the traditional TCP functionality in LabVIEW. An example string that connects with the NI FTP site is:
    "TCPIP::ftp.ni.com::21:OCKET"
    For INSTR connection, this requires a device that supports the T&M standard LAN instrument protocol. An example of this (that we have tested with) is the Tektronix 3054 Scope. A string that connects with this scope is: "TCPIP::HostnameOrIP::gpib0,1::INSTR"
    I hope this
    helps,
    Anthony Bacak
    National Instruments
    Applications Engineering

  • N6030A Connection with LabView

    Hi,
    I am working with N6030A connected to Laptop through MXI Express.
    I read http://forums.ni.com/ni/board/message?board.id=270&message.id=3106&requireLogin=False
    and it doesn't solve my problem, everything in IVI-drivers section on Measurement and Automatic Explorer seems to be alright
    I have a code in mathlab, which can strangely communicate with the N6030A. Moreover, the N6030A Control Utility can detect the N6030A address.
    However, I cannot even connect to this device with LabView.
    When I use a AGN6030A driver (AGN6030A Initialize with Option) on Labview and connect it with an IVI resource name, there is only "ASRL3::INST" address available, which I don't really know what kind of device it is. Anyway, the connection using this resource name doesn't work either.
    I have also tried to copy the resource name that is showed on my N6030 Control Utility, and it doesn't work.
    Can you guys help me.
    Thank you

    Hi,
    Which instrument driver did you download? Which hardware bus are you using (GPIB, PXI, ethernet, etc)? I assume your instrument is PXI based; is this correct?
    The resource name "ASRL3::INSTR" corresponds to your serial port in your computer. If you are connecting to your N6030A using this serial port, ASRL3::INSTR is the correct resource to choose.
    From searching the instrument driver network, it looks like this is the only instrument driver available. It does not look like it is an IVI driver, but instead a software utility that you can use to communicate with the instrument. How do you access this instrument through Matlab? Through a DLL? Through VISA?
    Regards
    Krista S.
    Applications Engineering
    National Instruments

  • K8047 Velleman connecting with labVIEW trouble

    Hi
    I have a K8047 Velleman datalogger and we want to connect this with Labview.
    This is the labVIEW program we used to read the data. (Found on this forum).
    I can find the K8047 in the  'Meassurement and Automation Explorer' by using the NI-VISA driver.
    After running this block program in labview, Here is no error code shown. But there is no data output on the screen too.
    What can be the problem?
    Thank you

    Ok thank you. We deleted the VISA Wizard. What do we need to do with the dll?
    There are two dll files...
    K8047D.dll
    FASTTIME32.dll
    We read on the forum that these two files as well as 
    K8047e.exe needs to be in the same folder as the VI.
    If we do so, we still get no  data?

  • Which stepper motor is required to connect with labview

    title:fault detection in pen. i am doing a project in image processing using labview .i want to  interface stepper motor with labview using daq how can i interface and which type of stepper motor is suitable for rolling metal sheet in which the pen is placed at the top

    I would start with the motor and work down, Labview will woek with any.
    1.  Figure out how much motor you need: torque, speed, resolution, size (nema 23, 34 .....)
    2.  Select a drive for your motor: many diferent drivers to control a particular motor, How much current is required, motor voltage, inductance
    3.  Determine the interface to the controller: step and direction, cw/ccw, serial.  (I  like step and direction)
    4.  Determine support options for the motor, encoders, limit switches ...
    5.  Now you can select your ni card to match the interface, (NI Motion- good for copmlex interfaces and multimotor synchronization, Digital/ counter timers simple but limited conmplexity, less expensive but more software needs to be written)
    This all depends on budget and requirements.
    Paul Falkenstein
    Coleman Technologies Inc.
    CLA, CPI, AIA-Vision
    Labview 4.0- 2013, RT, Vision, FPGA

  • Is it possible to get 2-ch signals from TDS2012 oscilloscope at the same time with LabVIEW "7.0"?

    Hi, everyone.
    I've been trying to get the signals from 2-ch of Tektronix TDS2012 oscilloscope at the same time using IVI connection with LabVIEW "7.0"
    I've already searched this developer zone for the answer.
    I've tried the famous example: "IviScope - Acq Dual Wfm Edge Triggered.vi"
    and it gave me the error message like:
    Error -1074110451 occurred at IviScope Initialize With Options.vi
    Possible reason(s):
    Driver Status:  (Hex 0xBFFA600D) Primary Error: (Hex 0xBFFA600D) The Config Server module is not present on the system.
    I think I've installed all~ the required softwares for IVI. For example, ICP 2.2, IVI engine 2.0.46, and tktds1k2k ivi (instrument driver for tds2012, in fact this one is for LabVIEW "7.1"... :-P)
    TDS2012 and my computer is connected through HPIB(GPIB) and it is shown on the MAX (a GPIB instrument as well as an IVI hardware asset)
    I've tried GPIB connection but it gives me asynchronous signals...
    Is it possible to get 2 signals at the same time with LabVIEW 7.0(not 7.1 or higher) by any means?
    What in the earth is the "Config Server" in this case?
    I don't need to sticking to IVI and any method to achieve my goal will be welcome.
    Could anyone give me the hint for this problem, plz?

    I think your problem is that the instrument specific driver is version 7.1 and you are using the class driver with 7.0. You can create your own 7.0 driver by downloading the LabWindows driver and using the Import CVI Instrument Driver under the Tools>Instrumentation menu.
    Since you don't seem to have a good reason to use IVI, why don't you try the native LabVIEW driver at http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=E3B19B3E9139659CE034080020E748.... I believe you have all of the functions to setup each channel and then when you trigger the scope, both channels will be captured. You would then transfer each waveform separately. The data is always read sequentially but that's not important as long as both channels are triggered at the same time.

  • Connect RS232 with labview to read current and voltage values.

    Hi, I am trying to connect my microcontroller kit which will measure the current and voltage. I was provided with rs232 port to connect with labview to read the voltage and current data that is measured by my controller. How to make it display both current and voltage value by acquirng the data from rs232. I tried some programming but it doesn't work or it was wrong. How to make it work ?
    Attachments:
    pro.vi ‏13 KB

    As we said in the other thread, you need to talk to whoever is designing the microcontroller and decide on a specific format for it send you the data.  Once we have that, then we can start talking about how to program this up.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • DIsplay Agilent E4438C ESG using NI-VISA GPIB

    Hi,
    I am currenty using labview to control Agilent E4438C to do a frequecny list sweep but how do I display the current frequecny the signal generator is at? I look through the VI in the instrument driver but I can't seem to find it. 

    Pete@Intel wrote:
    xsychox and others,
    The fundamental problem is that the Agilent SCPI command set doesn't provide a way to get the value of the current step state (frequency or amplitude) in a free-running/triggered list sweep.
    I understand the issue because I'm polling the actual injected power (which is not the same as the generator power) using an RF power meter and need to know the corresponding frequency.
    (I'm polling the ESG about once every 500ms during an extended, like 20 minutes, BER test - the ESG just happens to be the instrument that I'm using for an impariment source).
    The only solution that I have right now is to poll the ESG at the same rate as the dwell time per step and get a coarse approximation of the frequency based on time after the sweep is initiated.
    It's not as accurate as I'd like, but without a supported command it's a bit difficult.
    The other solution that I've considered is to emulate the list sweep by keeping my sweep list table in LabVIEW and then writing a loop to force each value using standard frequency and amplitude commands.
    When you are in the normal CW mode, the ESG driver frequency query works fine.
    I haven't implemented this because it's a bit of a change to some legacy code and I haven't had time to experiment with the implementation.
    I hope this is helpful.
    I think the second solution is the best option.  I think the reason why you can't get query the instrument during a sweep is because that sweep is a single command.  The next command cannot start until the last one completes.
    Bill
    (Mid-Level minion.)
    My support system ensures that I don't look totally incompetent.
    Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

  • Connecting Agilent DSO3062A Oscilloscope with LabVIEW using USB

    I am trying to connect Agilent DSO3062A Oscilloscope with LabVIEW using USB but the device is not recognized by MAX. I have installed the drivers for scope and it works fine with the scope software. The problem is LabVIEW dosen't recognize the scope. Please tell me the procedure of setting up the scope with LabVIEW 8.2. I am using Windows XP.

    Hi there,
    I think the issue is that the DSO3062A will not be recognized by LabView as a GPIB instrument through the USB connection. If you check out the 3000 series manual (http://cp.literature.agilent.com/litweb/pdf/D3000-97016.pdf) you'll notice on page 8 it says you can't use the USB for programming, it can only be used with their scope software. You need the N2861 module installed on the back to connect via GPIB, and then a GPIB interface to your computer. I hope that helps.
    -jmart

  • How to use labview with gpib to connect with Agilent PNA E8362B ?i am newbie ..just started to work on labview about a fortnite bck and a novice in interfacing skill ..so plzzzzz explain me in a litle detail

    how to use labview with gpib to connect with Agilent PNA E8362B ?i am newbie ..just started to work on labview about a fortnite bck and +i am a novice in interfacing(networking... jst know tidbits) skill ..so plzzzzz explain me in a litle detail

    Sir
    We were able to solve that problem...but now could you advice as to which DC power supply we should use (preferably avalable in India) so that it can be controlled by Labview (through a gpib/rs232/any other port) to give a square wave of desired frequency/other parameters.
    Regards
    Shivam

  • How to use labview with gpib to connect with Agilent PNA E8362B ?

    how to use labview with gpib to connect with Agilent PNA E8362B ?i am newbie ..just started to work on labview about a fortnite bck and +i am a novice in interfacing(networking... jst know tidbits) skill ..so plzzzzz explain me in a litle detail

    Duplicate Post.

  • Agilent 34401A multimeter to PC with Labview driver via RS232

    Hello!
    I am trying to measure a voltage with Agilent 34401A multimeter connected to PC via RS232 cable. I installed the driver. When I am starting Read Single Measurement.vi. It gives me an error:
    Error-1073807346 occured at Visa Open in Agilent 34401.lvlib: Initialize.vi->Agilent 34401 Read Single Measurement.vi
    Possible reason(s):
    Visa: (Hex 0xbFFF000E) The given session or object reference is invalid. 
    I would like to ask, how can I adjust my system to use RS23 with Agilent 34401A, if it is possible? If not, should I get GPIB card and cable?
    Thank you!
    Yulia.

    LabVIEW already comes with a driver for the 34401 pre-installed, so I'm not sure I understand what you installed. The pre-installed driver is in the Instrument I/O >> Instrument Drivers >> Agilent 34401 functions palette.
    As for the control that Dennis is referring to, it's the VISA control.
    As for the VISA version, you should have received a set of driver CDs along with LabVIEW. That will have the minimum VISA version required. Don't remember off the top of my head which version it is. Probably something like 4.1.
    Attachments:
    visa.png ‏42 KB

  • ThermoVisi​on Labview Digital Toolkit for connection with a FLIR SC645 is not working

    Can somebody help me?
    I have troubles connecting my FLIR SC 645 with my Labview Software.
    The “FLIR R&D Software” works fine I can make a connection with the camera over Ethernet, I can take images and read temperatures.
    Now I want to use the labview toolkit to automate the measurement in a production process.
    So the camera is connected over a Ethernet port directly to the PC.
    I can see the camera in NI MAX under NI-IMAQdx Devices. If I try to snap a image a error occurs:
    Error 0xBFF69031 The system did not receive a test pack from the camera.
    The package may be to long or a firewall may be enabled.
    When I dig in the libraries of ThermoVIsion I found the “ThermoVision Cam Ctrl.vit”. This program does work, it connects to the camera and I can do a internal calibration and some focusing but that is it. The examples from Thermovision does give me a black image and a Error -1.
    Does anyone has some experience with this toolkit?
    The main idée I had is to inport the image into a vision builder and their work with some intensity levels. Is this possible? And how do I connect with the camera?
    Hendrikx Danny

    Hello,
    usually IR cameras have dfferent pallete displays (monochrome, rainbow, saturation, etc...). The default is probably monochrome, that is why you are seeing it. You should be able to change the output by sending the appropriate command to the camera.
    Regarding the jumbo frames (I suggest that you leave this alone, if you get your camera working):
    let me google it for you 
    Best regards,
    K
    https://decibel.ni.com/content/blogs/kl3m3n
    "Kudos: Users may give one another Kudos on the forums for posts that they found particularly helpful or insightful."

Maybe you are looking for

  • Updating Safari 3.0.4 to 3.1.2

    After downloading safari updating 3.1.2 impossible to load the package Safari311UpdLeo.pkg. I receive the following message : "Vous ne pouvez pas installer Safari sur ce volume. Cette mise à jour requiert Mac OS X 10.5.2 ou ultérieur.(you cannot inst

  • Does JDeveloper embed a xsl fo processor ?

    I would generate output in html, rtf and pdf using xslt and xsl:fo and would know it it is necessary to install specific library or xml parser is enough. We are able to produce the xslt and xsl:fo script and only want to execute them from a our adf w

  • I need a Text to Speech conversion program

    Hi everyone, I need a program for conversion of text to speech(TTS) in java. If you have this program or website address. please send me as much fast as possible

  • How to Add Publisher Administrator Credentials to Oracle BI Presentation Services Credential Store

    I used to follow this document until 10g -  Bookshelf v10.1.3.2: Adding Publisher Administrator Credentials to Oracle BI Presentation Services Credential Store   Does anyone know how to configure the same in OBIEE 11G Thanks for your help Srix

  • Transport release strategies

    Hello! I have a question how to transport the release strategies (class, characteristics) from one client to another? Is there any pogram through se38? Thank you!