Controller - NMSP status inactive

Prime 1.2
Controller - NMSP status INACTIVE
I having a problem with one particular controller seen by my Standalone MSE
see snapshot below, I have 2 other old controllers running exactly the same code (4.2.207.0) which are seen by MSE as NMSP ACTIVE
Is there a setting I need to change on this particular controller?
NMSP Troubleshooting Checklist
Controller reachable from NCS
Controller reachable from MSE
Controller time after MSE time
MSE KeyHash present on the Controller
Controller Keyhash matches with the MSE
Pre-5.1.x.x Controller assigned to Single MSE

Take a look at this thread as it may help.
Thanks,
Scott
Help out other by using the rating system and marking answered questions as "Answered"

Similar Messages

  • MSE NMSP status inactive after WLC 5508 HA failover

    I have a customer who has a Prime Infrastructure 2.0 server and MSE 7.4 server for Context Aware Services.   The MSE also has the AeroScout Tag Engine for Tracking the AeroScout RFID tags it has deployed.    They have a WLC 5508 HA pair running version 7.4 at their main campus, and two other standalone WLC 5508s at 2 other smaller campuses.   The issue they are having is that when a failover of the WLC5508 HA pair occurs at their main campus, they lose tracking of the WiFi and AeroScout clients.   The other WLCs are not affected.
    When this happens, the Prime Infrastructure show the NMSP status of the WLC5508 HA pair as inactive.   The PI gives the message that the time of the WLC is before the MSE.  But the PI, MSE, and WLCs are all synched to the same Campus NTP server, and the time shows the same time down to the second.   I can get the WLC communicating to the MSE again by removing the Assignment of the WLC to the MSE, then re-adding it to the MSE a few minutes later. 
    We are not sure why the WLC 5508 HA pair occasionally fails over to the standby or back to the primary.  We have not seen any cause for the HA pair failover.   Is there something we need to do to the WLC HA pair so that the NMSP still works if a failover of the WLC occurs.  The customer is planning on converting one of their other Standalone WLCs to a HA Pair also.

    That is what I have been doing.  But the problem is that the I have had to do this about 3 times in the last 6 weeks.  Each time correlates with a failover of the WLC 5508 pair.   Will this have to be done each time there is a failover, or is there some setting on the WLCs, MSE, or Prime Infrastructure that can prevent  having manually to un-assign, then re-assign the WLC to the MSE.

  • Prime, MSE and WLC NMSP Status

    I have a 5508 WLC and have loaded a demo of Prime 2.1 and MSE 8.0.
    The NMSP status is showing as inactive in Prime and MSE and therefore the clients are not showing on the map I have loaded.
    Any ideas?

    MSE doesn't sync with WLC when added with PI 2.1.1
    CSCup93101
    Description
    Symptom:
    NMSP is not active between MSE and WLC when added using PI 2.1.1.
    Conditions:
    This applies to only MSE added Prime Infrastructure after upgrade to 2.1.1 on Prime Infrastructure.
    If the MSE was already added to Prime Infrastructure in 2.1 or previous releases, and then upgrade to PI 2.1.1 was performed customers will not run into the NMSP problem between MSE and WLC after the PI upgrade to PI 2.1.1.
    Workaround:
    Push a template (Templates > Features and Technologies > Controller > Security > AAA > AP or MSE Authorization) with MSE MAC address and key hash.
    Please contact Cisco TAC for a patch.
    Last Modified:
    Dec 11,2014
    Status:
    Fixed
    Severity:
    2 Severe
    Product:
    Network Level Service
    Known Affected Releases:
    (1)
    2.1(1)

  • CUCM 8.6.2 LDAP User Delete Pending LDAP Sync Status Inactive

    BE6K ver 8.6.2
    Client has a user who recently got married.  They changed her account information in Active Directtory to reflect her new last name. At that point CUCM shows her as
    Delete Pending
    LDAP Sync Status Inactive
    CUC shows
    LDAP User has been deleted.
    The user still exists in both CUC and CUCM and is actively takign and receiving calls.  User has VM access.
    Shorrt of deleting the user in AD and recreating her, is there a way to force this to re-sync?
    Thanks
    Matt

    Then that's expected to happen, for all purposes to CUCM/CUC eyes, msmith no longer exists and will be deleted, and a new user mjones now will be imported.
    Depending on when the change was done and when CUCM detected this, it might take up to 48 hours maximum to delete the user
    You'll need to associate everything to the new user, and also add that new user into CUC.
    Or switch back her userID to the old one, and just change the surname for directory purposes.
    HTH
    java
    if this helps, please rate
    www.cisco.com/go/pdihelpdesk

  • Storage 6180 - Both controller Battery status is Learning

    I have face the problem in 6180, battery not charging. So i have reset the controller. After reset the controller, controller battery is charged and alarm is cleared. But both controller battery status is showing learning. Kindly suggest.
    regards,
    Anwar

    user13590162 wrote:
    I have face the problem in 6180, battery not charging. So i have reset the controller. After reset the controller, controller battery is charged and alarm is cleared. But both controller battery status is showing learning. Kindly suggest.
    regards,
    AnwarA non authorative 'guess' is that the controller is attempting to learn the rate of discharge of the battery. It needs a little time (maybe quite a few hours, even a day) to do this.
    Batteries are a weak spot of things.
    Get prepared to replace the battery .... otherwise I suspect (and I know not the 6180 specifically and I am not bothered to look it up, you can as well as I), the appliance may degrade and run a little slower.

  • 3750 Integrated WirelessLAN Controller: Operational Status:resetting

    Hi there!
    A customer has a WS-C3750G-24WS-S50 WLC-Controller with exactly 50 APs. But those 50 Accesspoints are never completely registered to the WLC. Mostly there are 48-49 accesspoints registered but never 50.
    The WLC is losing them randomly. It is never losing the same Ap. When looking via GUI it says "All APs 50" , "Total 49".
    First of all I thought that I have the following problem:
    The 4402-50 controller supports a maximum of 50 access points and has two ports. To support the maximum number of access points, you would need to create two AP-manager interfaces (see Figure 3-15) because a 4400 series controller can support only 48 access points on one port.
    But this is not for the 3750  Integrated WirelessLAN Controller, because you have LAG enabled by default and you cannot change this. Therfore you are not able to create a second AP-Manager interface.
    So let´s forget about this.
    Then I tried some things on CLI an I noticed the following:
    sw-mr-01-01#sh platform wireless-controller 6
    Wireless Controller in Switch 6
    Operational Status of the Controller : resetting
    Service VLAN                         : 4095
    Service Port Mac Address             : 0025.8420.8e8f
    Service IP Address                   : 127.0.1.6
    Management IP Address                : 192.168.150.220
    Management VLAN                      : 0
    Software Version                     : 5.2.193.0
    Keepalive Version(controller/switch) : 1/1
    Keepalives Missed                    : 16
    Controller accepts http/https        : 0/1
    Controller's Status Line             : up
    Watchdog resets of Controller        : 1
    Controller resets total              : 0
    Unacknowledged control messages      : 27
    I guess it is not normal that the status is "resetting" although the WLC is running. I can work on GUI and CLI, so it is not really "resetting"
    According to the Config Guide status should be "operational".
    Is this maybe my problem? The customer is not able to do a good WIPT because the WLC is maybe resetting somehow internaly or something like this.
    In traps I got every minute "Lost heartbeat with supervisor" which normaly should be solved in earlier releases. I have 6.0.199.4
    HELP!!!
    Thanks in advance.

    Ok.
    1) Assing an IP address for a subnet you are sure you don´t use. for example 192.168.200.5 /24; GW 192.168.200.1 (via WLC GUI).
    2) I suppose (because I have not configured any 3750 WLC) that the service port uses the vlan ID 4095 (This is I saw in any capture). then you have to create a int vlan 4095 in the Switch and assing the GW ip address of your WLC service-port.
    3) Ping to verify conectivity between devices.
    I´m suppose you have the service port via DHCP (it could be the reason you have an IP 0.0.0.0), this is not a best practice; Cisco recommends that assing an IP to this interface and never let to DHCP, specially if you don´t have any dhcp server in this VLAN.
    Good Luck and sorry for my english.
    Best Regards.

  • CS11- BOM explosion with status inactive

    When a BOM is marked as inactive( at the header level), the BOM explosion using CS11 is not possible.  The systems says there is no effective BOM. However I can pull up the same using CS03 and drill down level by level.
    Is this standard SAP behaviour? Are there any settings in Customizing that will make the explosion for inactive BOM's  using CS11 possible?

    Alternative to select inactive BOM
    BOM status = inactive in BOM header
    In OS31
    Create a selection ID = 09, selection priority = 1, BOM usage = 1
    OS 30
    Create a BOm application copy from PP01 let us say ZP01
    In which enter the selection ID = 09, what you created before
    Remove all the ticks of check BOM
    Save
    That is all.
    In cs11, select the application as ZP01 and you will get the BOM explosion.

  • Status "Inactive" set for maintenance plan.

    Dear all,
    while doing
    Maintenance plan-->functions-->Activate<-->Inactive-->Deactive for maintenance plan
    which field and Table  we can able to get the details,Status "Inactive" set for maintenance plan.
    Required
    Changed by, Changed on , Deactivated field
    Regards,
    U.Linganathan

    Please refer MPLA table to OBJNR value.
    Refer JCDS & JEST tables to get the Inactive Maintenance plans.
    If Status I0320 is active in JEST table, then that Maintenance plan is Inactive.
    Pass INACT is not equal to "X" & OBJNR = "WO*" to get all Inactive Maintenance Plans OBJNR values. Pass that in MPLA table & get WARPL value.

  • Status inactive in v$session

    on what basis, session is shown as inactive in the status column of v$session..
    am connected through toad and execute so many queries, but still my session is shows as inactive ..
    can anyone shed some lite on this ?
    Kai

    Mark,
    DB:11.1.0.6
    O/S:Win XP Proff
    This is the output that I got from V$session which has got one user ,Aman connected and ran a long query which took sufficiently good amount of time to get complete.
    SQL> /
    STATUS   USERNAME
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    STATUS   USERNAME
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE   SYS
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    STATUS   USERNAME
    ACTIVE
    INACTIVE AMAN
    24 rows selected.
    SQL> /
    STATUS   USERNAME
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    STATUS   USERNAME
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE   SYS
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    ACTIVE
    STATUS   USERNAME
    INACTIVE AMAN
    23 rows selected.
    SQL> select status,username,last_call_e from v$session;
    select status,username,last_call_e from v$session
    ERROR at line 1:
    ORA-00904: "LAST_CALL_E": invalid identifier
    SQL> select status,username,last_call_et from v$session;
    STATUS   USERNAME                       LAST_CALL_ET
    ACTIVE                                             8
    ACTIVE                                          5124
    ACTIVE                                          5392
    ACTIVE                                          5392
    ACTIVE                                          5402
    ACTIVE                                          5406
    ACTIVE                                          5406
    ACTIVE                                          2399
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5430
    STATUS   USERNAME                       LAST_CALL_ET
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE   SYS                                       0
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5430
    ACTIVE                                          5436
    STATUS   USERNAME                       LAST_CALL_ET
    ACTIVE                                          5436
    INACTIVE AMAN                                     36
    24 rows selected.
    SQL>I guess,you must have noticed too.There is one session which gets added and removed on its own. I am getting 23 rows and than 24 ,the second last one becomes an active session but my session,Aman's,remains inactive only. The last_call_et column is also shown which according to docs,is showing time period of staying inactive. Interstingly, I couldn't make my user's status changed to Active. My best guess is that it might have become active when the call was submitted but after that it has become inactive again.I surely can be wrong but just wanted to share my thought.If you can explain the behaviour in more detail,it will be great.
    Regards
    Aman....

  • Adapter status -inactive

    Hi
           In file adapter i changed Server Details, after that i saved it and activated,
           in configuration it showing status as active, but in RWB in adapter monitoring
    it showing status as inactive(gray colour), pls tell me, how can i change it into green colour?

    Surya,
    In which SP u are currently working in. Coz if u are in SP18 and above(I believe) there is option in RWB communication channel monitoring instead of adapter monitoring. If you have comm.channel monitoring option then there is option of making particular comm.channel active and inactive over there. Kindly make it active over there.
    Hope it helps.
    Best regards,
    raj.

  • Database Status Inactive Sessions

    On OAM Applications Dashboard > Navigate to "DATABASE STATUS" > Sessions "#"
    I see alot of inactive sessions. Is it okay to terminate all of the inactive sessions? does it affect system performance? THanks!
    Message was edited by:
    chaseeem

    Oracle will clean them up for you. In addition, you could terminate a session that's simply idle.

  • Connection Status INACTIVE (Oracle Dev tools EntityFramework)

    Hello,
    I am using the EF ObjectContext in a C++ application (via COM) - I wrapped the context in an exposed class to COM in .NET - and once I finish with the COM object, I uninitialize COM (CoUninitialize();) and the finalizer of the wrapped class is called where I do a context.Dispose(); context = null;.
    My problem is that the connection status (select username,program,machine,status FROM V$SESSION where username is not null;) is INACTIVE after disposing the context and this causes problems when the number of licenses is reached.
    How can I force the connection to close?
    Thanks

    ODP uses connection pooling by default; if you want to turn it off, add "pooling=false" to your connect string.
    Note that this will result in slower performance as apart from having to open a hard connection every time you call con.Open, it also disables things like statement caching.
    Greg

  • Back dated action  which is changing the status ' inactive'

    hi friends,
    my requirement is as below :
    i want to insert  back dated action which is changing the status as inactive ( currently he is active) .
    System is not accepting to insert it and giving the message "   future action exists,check the status"
    So for that first i am deleting  all future actions and inserting the current action(which is changing status) and after inserting back  all the deleted actions.
    But the problem is  as per the latest records in IT0000 it is showing currently the  employee is in 'active' status(as we have inserted back the deleted records).
    But i want to make him into 'inactive' status after the current action( which is changing status as inactive) is inserted.
    This is my urgent requirement . an anybody respond to this immeadately.
    waiting for ur reply.
    thanks in advance.

    Hi Gajesh,
                     The process is as follows :
    1) During Calibration of a product,depending on the technician's User decision , 3 follow up actions are created.
    2) Each follow up action has one FM associated with it, which is customised in      SPRO > Display IMG > Quality Management > Quality Inspection > Inspection Lot Completion > Define follow-Up Action .
    3) In the first case ( first Follow up action when the inspection is successful) the first FM is triggered. In this FM we have to perform the following steps :
                                   a) Determine the Maintenance Order and the equipment.
                                   b) Incase both are available, status of equipmnt should be changed to 'A',
                                       Maintenance Order should be changed to 'Technically completed' and
                                       Maintenance Notification to 'Notification Completed' .
    If you need further info pls let me know.
    Thanks,
    Vasuki

  • NCS Prime 1.3 Controller Audit Status Mismatch

    When performing an audit from NCS Prime 1.3 on our 5508 controllers (500 lic)  we are getting mismatch messages from many of our 3602i AP's that say the following...
              (Type)Configuration Name     Audit Status              Attribute           Prime Infrastructure Value     Controller Value
    (AP APname, Interface) 802.11a/n     Mismatch     Spectrum Intelligence      true                                       false
    These AP's are not configured as Spectrum Intelligence on the controllers, rather as local. It seems that NCS believes that they are supposed to be SI. We have refreshed the config from controller many times but this does not change.
    The 5508's run v.7.2.111.3
    Is there a change I can make on NCS or otherwise to make this mismatch go away? Is this a bug? It is not causing any problems (that we can see) but as most would rather not have these mismatches.
    Much Thanks!

    Well when you do an audit, you specify what templates you want to audit the WLC's against. So take a look at when you perform an audit as to what tempted you have chosen. This could of been an old template and needs to be removed.
    Sent from Cisco Technical Support iPhone App

  • AirPort Status INACTIVE

    my airport status alwez inactive, i cant connect to any network around my area,how make it wakeup from sleep?...please help me...it already more two weeks i have been try to fixed this problem till i bought the external usb wifi...because of this..

    ULTIMATI wrote:
    my airport status alwez inactive, i cant connect to any network around my area,how make it wakeup from sleep?
    It may not help, but you might try resetting your connection settings using the steps listed in the second message of this thread:
    http://discussions.apple.com/thread.jspa?messageID=10695921

Maybe you are looking for

  • SRM automatic Purchase Order Creation

    Is it possible to automatically create a purchase order after the shopping cart has been approved even if the shopping cart was not created from a catalog. We want to have the buyer as the first release point for the shopping cart, where the buyer wi

  • How to know what outlook profile is required?

    Hi, I'm changing my pc in this other pc I want to setup iCloud then firstly I setup my email account in Outlook now it is working fine,  but when I open iCloud and select contacts to be sincronized, I get an error message about "Outlook is not setup

  • Writting java graphics and textual data from java application into MS word

    By using POI API, I could write textual data into MS word by using java application. Could any one help me out how to write Java graphics(i.e. Writting JPanel) and textual data(i.e.IOStream data) both into MS word document. Thank you for time spent.

  • No ringtone for incoming email

    I have a ringtone set for incoming email but it doesn't activate when an email has come in. What am I doing wrong?

  • A method completes partially???

    Hi I'm using a method developped by myself which compares two arrays and if there are equal items deletes them all and returns an array of items that were not in any of the compared arrays. But, my program executes those methods many times in a row,