Conversion with Function Module method

Hi all,
I have a problem . I have to upload the data into database by conversion method . I got a function module for my task SD_CONDITION_VAKEY_FILL and RV_KONDITION_SICHERN_V13A. Please guide me how to load a daat with these FM's

Hi,
Look at the below link
Re: pricing conditions updation
Regards
Sudheer

Similar Messages

  • Error with quantity field:Datasource Creation Using Function Module method

    Problem with DATASOURCE Creation using Function Module method :
    I have created a datasource ZSTANDARD_COST_PRICE using Function Module method . The datasource creation is successfull when I remove the quantity field from the Z table . If I dont remove the quantity field from my Z table it gives an error as "Units Field WAERS for field STPRS of datasource ZSTANDARD_COST_PRICE is hidden". I am not able to remove this error . Please someone guide.
    Let me know if my explanation is not clear enough.
    Thanks in advance,
    Neha.
    Z table definition is as below :
    MATNR MATNR CHAR 18 0 Material Number
    BWKEY BWKEY CHAR 4 0 Valuation area
    LFGJA LFGJA NUMC 4 0 Fiscal Year of Current Period
    STPRS STPRS CURR 11 2 Standard Price   " Here the currency field is WAERS and table T001
    PEINH PEINH DEC 5 0 Price Unit
    VJSTP VJSTP CURR 11 2 Standard price in previous year
    VJPEI VJPEI DEC 5 0 Price unit of previous year.
    Edited by: Neha Rathi on Jan 30, 2009 3:03 PM

    Hi,
    You should add it as one of the main fields as you have added other fields and not as the currency fields...that is..it should be part of the data source and you should be able to see it in RSO2...
    Also if added as i said then it will come as new field in the data source...you can either let it be there...or hide it..
    also if you want to populate it then you will have to write the code for this fields as well.
    Thanks
    Ajeet

  • Replacement function modules/method for obsolete Funtion Modules in ECC 6.0

    We are working on Upgrade Project and need your help in finding the replacement Function module/ Methods for following obsolete Function Modules:
       1.   GET_FIELDTAB
       2.   WS_EXCEL
       3.  HR_DISPLAY_BASIC_LIST
       4.  LOG_SYSTEM_GET_RFC_DESTINATION
       5.  HELPSCREEN_NA_CREATE
       6. TR_RELEASE_COMM
    Thank in Advance.
    Sarita.
    Edited by: Sarita Yalamati on Mar 28, 2008 1:23 PM

    Hi sarita,
    for GET_FIELDTAB use 'DDIF_NAMETAB_GET'..here is sample code
      CALL FUNCTION 'GET_FIELDTAB'
           EXPORTING
                LANGU               = SY-LANGU
                TABNAME             = C_STRUCTURE_NAME
                WITHTEXT            = ' '
           TABLES
                FIELDTAB            = IDFIES
           EXCEPTIONS
               INTERNAL_ERROR      = 01
                NO_TEXTS_FOUND      = 02
                TABLE_HAS_NO_FIELDS = 03
                TABLE_NOT_ACTIV     = 04.
    Replacement :
    CALL FUNCTION 'DDIF_NAMETAB_GET'
      EXPORTING
        TABNAME           =  C_STRUCTURE_NAME
      ALL_TYPES         = ' '
      LFIELDNAME        = ' '
      GROUP_NAMES       = ' '
      UCLEN             =
    IMPORTING
      X030L_WA          =
      DTELINFO_WA       =
      TTYPINFO_WA       =
      DDOBJTYPE         =
      DFIES_WA          =
      LINES_DESCR       =
    TABLES
      X031L_TAB         =
       DFIES_TAB         = IDFIES
    EXCEPTIONS
       NOT_FOUND         = 1
       OTHERS            = 2
    For WS_EXCEL  use GUI_DOWNLOAD.. here is sample code
    CALL FUNCTION 'WS_EXCEL'
    EXPORTING
       FILENAME            = 'D:\FILE1.xls'
      SYNCHRON            = ' '
      TABLES
        DATA                = itab
    EXCEPTIONS
       UNKNOWN_ERROR       = 1
       OTHERS              = 2
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
             WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    Repalcement :
    data : l_filename type string.
    l_filename  = 'D:\FILE1.xls'.
    CALL FUNCTION 'GUI_DOWNLOAD'
      EXPORTING
      BIN_FILESIZE                    =
        FILENAME                        = l_filename
      FILETYPE                        = 'ASC'
    IMPORTING
      FILELENGTH                      =
      TABLES
        DATA_TAB                        = itab
      FIELDNAMES                      =
    EXCEPTIONS
       FILE_WRITE_ERROR                = 1
       NO_BATCH                        = 2
       GUI_REFUSE_FILETRANSFER         = 3
       INVALID_TYPE                    = 4
       NO_AUTHORITY                    = 5
       UNKNOWN_ERROR                   = 6
       HEADER_NOT_ALLOWED              = 7
       SEPARATOR_NOT_ALLOWED           = 8
       FILESIZE_NOT_ALLOWED            = 9
       HEADER_TOO_LONG                 = 10
       DP_ERROR_CREATE                 = 11
       DP_ERROR_SEND                   = 12
       DP_ERROR_WRITE                  = 13
       UNKNOWN_DP_ERROR                = 14
       ACCESS_DENIED                   = 15
       DP_OUT_OF_MEMORY                = 16
       DISK_FULL                       = 17
       DP_TIMEOUT                      = 18
       FILE_NOT_FOUND                  = 19
       DATAPROVIDER_EXCEPTION          = 20
       CONTROL_FLUSH_ERROR             = 21
       OTHERS                          = 22
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
             WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    CALL METHOD CL_GUI_FRONTEND_SERVICES=>EXECUTE
      EXPORTING
        DOCUMENT               = 'D:\FILE1.xls'
       APPLICATION            =
       PARAMETER              =
       DEFAULT_DIRECTORY      =
       MAXIMIZED              =
       MINIMIZED              =
       SYNCHRONOUS            =
        OPERATION              = 'OPEN'
      EXCEPTIONS
        CNTL_ERROR             = 1
        ERROR_NO_GUI           = 2
        BAD_PARAMETER          = 3
        FILE_NOT_FOUND         = 4
        PATH_NOT_FOUND         = 5
        FILE_EXTENSION_UNKNOWN = 6
        ERROR_EXECUTE_FAILED   = 7
        SYNCHRONOUS_FAILED     = 8
        NOT_SUPPORTED_BY_GUI   = 9
        others                 = 10
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
                WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.

  • Function Module to retrive conversion exit function module names based on conversion routine

    Hi All,
    Can you people help me out in finding a function module, which takes conversion routine name as input and gives all the conversion exit function modules as output.
    Thanks and Regards,
    Shivaraj Naik.

    Curious, I looked for the way SAP do the job in SE11, and they also use the CONCATENATE option...
    From Include LSD11F01 Form OBJ_GOTO
    *       Objektspezifische Navigationsziele
    *      --> GOTOID   Kennung für Navigationsziele
    *      --> DDNAME   Dictonary-Name
    form obj_goto using  gotoid type gotoid
                         ddname.
      case gotoid.
        when 'CNVE'.   "Konvertierungsexit zu Domäne
          data: wb_request type ref to cl_wb_request.
          data: fb_name like tfdir-funcname
                            value 'CONVERSION_EXIT_'.
          concatenate fb_name ddname '*' into fb_name.
          condense fb_name.
    * Request für Infosystem erzeugen
          class cl_wb_infosystem definition load.
          call method cl_wb_infosystem=>create_request
            exporting
              p_object_type        = 'FF'
              p_object_name        = fb_name
              p_operation          = swbm_c_op_search
              p_suppress_selection = 'X'
              p_show_as_popup      = 'X'
            importing
              p_wb_request         = wb_request
            exceptions
              action_cancelled     = 1
              execute_in_batch     = 2
              error_occured        = 3.
    Regards,
    Raymond

  • To update Employee Data with Function module

    Hi
    CRM employee master and HR employee master need to be mapped
    for the labor cost posting function to work.
    In BP transaction (Change in BP role : Employee),
    I could update "Personnel number" and "User Name"
    under Identification Tab
    now I need to do same job with Function module in report program.
    Anybody knows that what Function module should I use ?
    I tryed to do it with Function "CRMXIF_PARTNER_SAVE"
    but I only succesed to update imformations under Adress tab in BP transaction.
    thank you.

    Use FM BAPI_BUPA_CREATE_FROM_DATA.
    Rg,
    Harshit

  • How to copy a generic extractor with function module into a new system?

    Dear Gurus,
    i would like to know how i can copy a gneric datasource with function module from one system to the target system.
    Thank you
    Cheers

    Hi Anesh,
    thank you for replying.
    Since the Datasource will have a new new in the new system, i will create a new one.
    Create a generic datasource base on the table is not the problem.
    My problem is how could i copy the FM in the new system?
    If you can help me on that, it will be fine.
    Thanks

  • VirtualProvider with Function Module

    Hi,Experts
    Can anyone tell me how to create a VirtualProvider with Function Module?
    I have read the How to guide"How to Implement a VirtualProvider with service",but I can't go throw the source code.
    Please give me a sample test code of yours!
    Thanks a lot!
    My Email:[email protected]

    Hi Jin
    This question does not belong to this forum, close it and post it in the appropriate one.
    Also, please remove your email address from the thread as it violates the forum guidelines.

  • Hierarchial Layout Saving with function modules

    Hai to all
    i am facing a problem while saving layout in Hierarchial list display with function module.
    below error message is coming when i am going save my layout.
      210     if l_def_variant-variant eq rs_variant-variant.                
      211       l_default = 'X'.                                             
      212     endif.                                                         
      213   endif.                                                           
      214                                                                    
      215   call function 'LT_FC_SAVE'                                       
      216        exporting                                                   
      217 *           I_TOOL            = 'LT'                               
      218             i_tabname         = r_tabname                          
      219             i_tabname_slave   = r_tabname_slave                    
      220             is_variant        = rs_variant                         
      221             it_fieldcat       = rt_fieldcat[]                      
      222             it_sort           = rt_sort[]                          
      223             it_filter         = rt_filter[]                        
      224             is_layout         = rs_layout                          
      225             i_default_variant = l_default                          
      226        exceptions                                                  
      227             fc_not_complete = 1                                    
      228             others          = 2.                                   
      229   case sy-subrc.                                                   
      230     when '0'.                                                      
      231       message s018(0k).                                            
      232     when '1'.                                                      
    >>>>>       message x000(0k) with 'LT_FC_SAVE' sy-subrc                  
      234               raising fc_not_complete.                             
      235   endcase.                                                         
    it is very urgent...
    Subhash.M

    data: ls_vari      type disvariant.
    DATA: w_repid      TYPE sy-repid.
      ls_vari-report      = w_repid.
      ls_vari-username    = sy-uname.
      CALL FUNCTION 'REUSE_ALV_HIERSEQ_LIST_DISPLAY'
        EXPORTING
      I_INTERFACE_CHECK              = ' '
         i_callback_program             = w_repid
      I_CALLBACK_PF_STATUS_SET       = ' '
      I_CALLBACK_USER_COMMAND        = ' '
         is_layout                      = wa_layout
          it_fieldcat                    = i_fcat[]
      IT_EXCLUDING                   =
      IT_SPECIAL_GROUPS              =
       it_sort                        = i_sort[]
      IT_FILTER                      =
      IS_SEL_HIDE                    =
      I_SCREEN_START_COLUMN          = 0
      I_SCREEN_START_LINE            = 0
      I_SCREEN_END_COLUMN            = 0
      I_SCREEN_END_LINE              = 0
         i_default                      = 'X'
         i_save                         = 'X'
       IS_VARIANT                     = ls_vari
       it_events                      = i_event[]
      IT_EVENT_EXIT                  =
          i_tabname_header               = 'I_FINAL1'
          i_tabname_item                 = 'I_FINAL2'
      I_STRUCTURE_NAME_HEADER        =
      I_STRUCTURE_NAME_ITEM          =
          is_keyinfo                     = wa_key
      IS_PRINT                       =
      IS_REPREP_ID                   =
      I_BYPASSING_BUFFER             =
      I_BUFFER_ACTIVE                =
      IR_SALV_HIERSEQ_ADAPTER        =
      IT_EXCEPT_QINFO                =
      I_SUPPRESS_EMPTY_DATA          = ABAP_FALSE
    IMPORTING
      E_EXIT_CAUSED_BY_CALLER        =
      ES_EXIT_CAUSED_BY_USER         =
        TABLES
          t_outtab_header                = i_final1
          t_outtab_item                  = i_final2
    EXCEPTIONS
       PROGRAM_ERROR                  = 1
       OTHERS                         = 2
      IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
             WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    i have passed the parameters
    but i am getting same dump again..
    Subhash.M

  • Generic Data Source with Function Module data mismatch in BI

    Hi All,
    I'm using Generic Data Source with Function Module, When I execute the Function Module (Which I have Created), I'm getting 16000 records and when run extractor(in RSA3) im getting different no.of records(infact they are more no.).
    when I run the InfoPackage in BI im Getting more no. of records than what i got executing the function module..
    and single record is divided into 2 records in BI side(not all the records), how can it be possible???
    is there anything Im missing to explain you my issue???
    if understood please help me out.
    Thanks n Regards,
    ravi.

    the datasource frame work starts the function module several times.
    1. the initialization
    2. the serval times, until you "raise no_more_data".
    check you coding: have you refreshed necessary internal tables.
    Sven

  • Generic Data Source with Function Module data mismatch

    Hi All,
    I'm using Generic Data Source with Function Module, When I execute the Function Module (Which I have Created), I'm getting 16000 records and when run extractor(in RSA3) im getting different no.of records(infact they are more no.).
    when I run the InfoPackage  in BI im Getting more no. of records than what i got executing the function module..
    and single record is divided into 2 records in BI side(not all the records), how can it be possible???
    is there anything Im missing to explain you my issue???
    if understood please help me out.
    Thanks n Regards,
    ravi.

    HI rkiranbi,
    1. FIrst you excute function module according to your paramers, you will get some records. then goto tcode RSA3 --> excute
    Provide your Data source name and under setting we have options like Data records/calls, Display extractor calls and selections --> fields .
    in that options you have to increase the values. and then you have to pass paramers in RSA3 according to your function module
    selections in SE37. Now you will get equal values in both functin module selection and RSA3 Selection. if it fail means  you need to
    check coding logic in function module. 
    2. if your  are getting wrong values in BI System then check with
                  1. compare with PSA data and data target data (here you need to check with characterstic as well as keyfigures)
                  if you find any mistake you need change the coding in function module according to client requirement.
                  2. compare data with RSA3 and bi report data or data target data.
                                 check it properly above steps, you will get solution.
    thanks and regards,
    malli

  • VirtualProvider with Function module problem !

    I implemented virtualprovider with function module. Unfortunately  when I run query i get message error :
    u201CFunction call of ZT0X failed; the obligatory parameter CHARACTERISTICS
    An exception with the type CX_SY_DYN_CALL_PARAM_MISSING occurred, but was
    I>> Row: 67 Inc: READ_DATA Prog: CL_RSDRV_VPROV_LOC_NOSIDu201D
    Any suggestions ?
    Below source code:
    u201CFUNCTION ZT0X.
    ""Lokalny interfejs:
    *"  IMPORTING
    *"     VALUE(INFOCUBE) LIKE  BAPI6200-INFOCUBE DEFAULT 'ZT03'
    *"     VALUE(KEYDATE) LIKE  BAPI6200-KEYDATE OPTIONAL
    *"  EXPORTING
    *"     VALUE(RETURN) LIKE  BAPIRET2 STRUCTURE  BAPIRET2
    *"  TABLES
    *"      SELECTION STRUCTURE  BAPI6200SL
    *"      CHARACTERISTICS STRUCTURE  BAPI6200FD
    *"      KEYFIGURES STRUCTURE  BAPI6200FD
    *"      DATA STRUCTURE  BAPI6100DA
    DATA:
        l_r_srv              TYPE ref to CL_RSDRV_REMOTE_IPROV_SRV,
        l_th_mapping         TYPE CL_RSDRV_REMOTE_IPROV_SRV=>TN_TH_IOBJ_FLD_MAPPING.
    *  break-point ID ZRSDRV_RC1.
    * break DEVELOPER.
      perform build_mapping_table
        changing l_th_mapping.
      create object l_r_srv
        exporting
          i_tablnm              = '/BIC/PZPRD_ID'
          i_th_iobj_fld_mapping = l_th_mapping.
      l_r_srv->open_cursor(
        i_t_characteristics = characteristics[]
        i_t_keyfigures      = keyfigures[]
        i_t_selection       = selection[] ).
       l_r_srv->fetch_pack_data(
        importing
          e_t_data = data[] ).
      return-type = 'S'.
    ENDFUNCTION.
    &---- <
    *&        Form  build_mapping_table
    &---- <
    Form build_mapping_table
      changing
        c_th_mapping TYPE CL_RSDRV_EXTERNAL_IPROV_SRV=>TN_TH_IOBJ_FLD_MAPPING.
      DATA:
        l_s_map TYPE CL_RSDRV_EXTERNAL_IPROV_SRV=>TN_S_IOBJ_FLD_MAPPING.
      l_s_map-iobjnm = 'ZPRD_ID'.
      l_s_map-fldnm  = '/BIC/ZPRD_ID'.
      insert l_s_map into table c_th_mapping.
      l_s_map-iobjnm = 'ZWARTOSC'.
      l_s_map-fldnm  = '/BIC/Z_CEN_W'.
      insert l_s_map into table c_th_mapping.
    +endform.u201D

    Hello
    I experienced the same issue. Were u able to solve it? If yes , kindly ask you to make posting here so that others can benefit as well.
    Huge thanks

  • Function Module/Method for opening path on frontend

    Hi,
    I am looking for an function module or a method of a class which can be used for opening (in windows) an explorer-window with a given path.
    I don't wanna select any files of directories there, only opening the windows and processing the normal logic of the application.
    Can you give me any hints how to do that?
    Kind regards
    Markus

    Sample Code:
    data : file_table like table of SDOKPATH with header line .
    data : dir_table like table of SDOKPATH with header line .
    data : file_count type i ,
           dircount   type i .
    parameters:p_dir(50) type c.
    CALL FUNCTION 'TMP_GUI_DIRECTORY_LIST_FILES'
    EXPORTING
    DIRECTORY = p_dir
    FILTER = '*.TXT'
    IMPORTING
    FILE_COUNT = file_count
    DIR_COUNT =  dircount
    TABLES
    FILE_TABLE = file_table
    DIR_TABLE = dir_table
    EXCEPTIONS
    CNTL_ERROR = 1
    OTHERS = 2.
    write:/ 'no of files in the floder is : ', file_count .
    skip 32.
    loop at file_table .
    write:/ file_table-PATHNAME.
    endloop.
    cheers
    s.janagar

  • Delta extraction(date) with Function module problem

    Hi All,
    FUNCTION zrsax_biw_get_data_pr_d.
    *"*"Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SBIWA_S_INTERFACE-REQUNR
    *"     VALUE(I_ISOURCE) TYPE  SBIWA_S_INTERFACE-ISOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SBIWA_S_INTERFACE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SBIWA_S_INTERFACE-INITFLAG OPTIONAL
    *"     VALUE(I_UPDMODE) TYPE  SBIWA_S_INTERFACE-UPDMODE OPTIONAL
    *"     VALUE(I_DATAPAKID) TYPE  SBIWA_S_INTERFACE-DATAPAKID OPTIONAL
    *"     VALUE(I_PRIVATE_MODE) OPTIONAL
    *"     VALUE(I_CALLMODE) LIKE  ROARCHD200-CALLMODE OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SBIWA_T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SBIWA_T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZPR_ST OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    * The input parameter I_DATAPAKID is not supported yet !
    * Example: InfoSource containing TADIR objects
    *  TABLES: tadir.
    *DATA: BEGIN OF zpr_st_copy,
    *        banfn TYPE zpr_st-banfn,
    *        bnfpo TYPE zpr_st-bnfpo,
    *        zebkn TYPE zpr_st-zebkn,
    *        knttp TYPE zpr_st-knttp,
    *        vbeln TYPE zpr_st-vbeln,
    *        ps_psp_pnr TYPE zpr_st-ps_psp_pnr,
    *        gsber TYPE zpr_st-gsber,
    *        werks TYPE zpr_st-werks,
    *        statu TYPE zpr_st-statu,
    *        ekgrp TYPE zpr_st-ekgrp,
    *        menge TYPE zpr_st-menge,
    *        frgdt TYPE zpr_st-frgdt,
    *        meins TYPE zpr_st-meins,
    *         loekz TYPE zpr_st-loekz,
    *      END OF zpr_st_copy.
    * Auxiliary Selection criteria structure
      DATA: l_s_select TYPE sbiwa_s_select.
    * Maximum number of lines for DB table
      STATICS: l_maxsize TYPE sbiwa_s_interface-maxsize.
    * Select ranges
    *  RANGES: l_r_pgmid  FOR tadir-pgmid,
    *          l_r_object FOR tadir-object,
        RANGES: PRNO for zpr_st-banfn,
                DATE1 FOR zpr_st-frgdt.
    * Parameter I_PRIVATE_MODE:
    * Some applications might want to use this function module for other
    * purposes as well (e.g. data supply for OLTP reporting tools). If the
    * processing logic has to be different in this case, use the optional
    * parameter I_PRIVATE_MODE (not supplied by BIW !) to distinguish
    * between BIW calls (I_PRIVATE_MODE = SPACE) and other calls
    * (I_PRIVATE_MODE = X).
    * If the message handling has to be different as well, define Your own
    * messaging macro which interprets parameter I_PRIVATE_MODE. When
    * called by BIW, it should use the LOG_WRITE macro, otherwise do what
    * You want.
    * Initialization mode (first call by SAPI) or data transfer mode
    * (following calls) ?
      IF i_initflag = sbiwa_c_flag_on.
    * Initialization: check input parameters
    *                 buffer input parameters
    *                 prepare data selection
    * The input parameter I_DATAPAKID is not supported yet !
    * Invalid second initialization call -> error exit
        IF NOT g_flag_interface_initialized IS INITIAL.
          IF 1 = 2. MESSAGE e008(r3). ENDIF.
          log_write 'E'                    "message type
                    'R3'                   "message class
                    '008'                  "message number
                    ' '                    "message variable 1
                    ' '.                   "message variable 2
          RAISE error_passed_to_mess_handler.
        ENDIF.
    * Check InfoSource validity
        CASE i_isource.
          WHEN 'ZPR_ST_DS_D' OR ''.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e009(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      i_isource            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    * Check for supported update mode
        CASE i_updmode.
          WHEN 'F' OR ''.
          WHEN 'C'.
          WHEN 'R'.
          WHEN 'S'. " DELTA INITIALIZATION
          WHEN 'I'. "DELTA INITIALIZATION FOR NON CUMULATIVE
          WHEN 'D'. "DELTA
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e011(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '011'                "message number
                      i_updmode            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    BREAK-POINT.
    * Check for obligatory selection criteria
    *    READ TABLE i_t_select INTO l_s_select WITH KEY fieldnm = 'ZPR_ST-FRGDT'.
    *    IF sy-subrc <> 0.
    *      IF 1 = 2. MESSAGE e010(r3). ENDIF.
    *      log_write 'E'                    "message type
    *                'R3'                   "message class
    *                '010'                  "message number
    *                'PGMID'                "message variable 1
    *                ' '.                   "message variable 2
    *      RAISE error_passed_to_mess_handler.
    *    ENDIF.
        APPEND LINES OF i_t_select TO g_t_select.
    * Fill parameter buffer for data extraction calls
        g_s_interface-requnr    = i_requnr.
        g_s_interface-isource   = i_isource.
        g_s_interface-maxsize   = i_maxsize.
        g_s_interface-initflag  = i_initflag.
        g_s_interface-updmode   = i_updmode.
        g_s_interface-datapakid = i_datapakid.
        g_flag_interface_initialized = sbiwa_c_flag_on.
    * Fill field list table for an optimized select statement
    * (in case that there is no 1:1 relation between InfoSource fields
    * and database table fields this may be far from beeing trivial)
        APPEND LINES OF i_t_fields TO g_t_segfields.
    *   Start tracing of extraction
    *    bice_trace_open g_r_tracer i_t_fields.
      ELSE.                 "Initialization mode or data extraction ?
    * Data transfer: First Call      OPEN CURSOR + FETCH
    *                Following Calls FETCH only
    * First data package -> OPEN CURSOR
        IF g_counter_datapakid = 0.
    * Fill range tables for fixed InfoSources. In the case of generated
    * InfoSources, the usage of a dynamical SELECT statement might be
    * more reasonable. BIW will only pass down simple selection criteria
    * of the type SIGN = 'I' and OPTION = 'EQ' or OPTION = 'BT'.
    *      LOOP AT g_t_select INTO l_s_select WHERE fieldnm = 'PGMID'.
    *        MOVE-CORRESPONDING l_s_select TO l_r_pgmid.
    *        APPEND l_r_pgmid.
    *      ENDLOOP.
    *      LOOP AT g_t_select INTO l_s_select WHERE fieldnm = 'OBJECT'.
    *        MOVE-CORRESPONDING l_s_select TO l_r_object.
    *        APPEND l_r_object.
    *      ENDLOOP.
    LOOP AT g_t_select INTO l_s_select WHERE fieldnm = 'ZPR_ST-FRGDT'.
                MOVE-CORRESPONDING l_s_select to DATE1.
                DATE1-sign = 'I'.
                DATE1-option = 'GE'.
                clear DATE1-high.
                APPEND DATE1.
          ENDLOOP.
    * Determine number of database records to be read per FETCH statement
    * from input parameter I_MAXSIZE. If there is a one to one relation
    * between InfoSource table lines and database entries, this is trivial.
    * In other cases, it may be impossible and some estimated value has to
    * be determined.
          l_maxsize = g_s_interface-maxsize.
          OPEN CURSOR WITH HOLD g_cursor FOR
    *      SELECT (g_t_fields) FROM tadir
    *                               WHERE pgmid  IN l_r_pgmid AND
    *                                     object IN l_r_object.    "#EC CI_GENBUFF
    *@ CODE FOR THE STRUCTURE TO FILL IN FROM EBAN AND EBKN@*
                SELECT a~banfn a~bnfpo k~zebkn a~knttp k~vbeln k~ps_psp_pnr k~gsber a~werks a~statu a~ekgrp a~menge a~menge a~frgdt a~meins
    * INTO CORRESPONDING FIELDS OF TABLE IT1
                FROM  eban AS a INNER JOIN ebkn AS k ON ( a~banfn = k~banfn AND a~bnfpo = k~bnfpo )
                WHERE a~banfn GE '2000000000' AND a~banfn LE '2999999999' and a~loekz eq ' ' and a~frgdt ge '20130401' and a~FRGKZ eq '2'.
    *BREAK-POINT.
        ENDIF.                             "First data package ?
    * Fetch records into interface table. There are two different options:
    * - fixed interface table structure for fixed InfoSources have to be
    *   named E_T_'Name of assigned source structure in table ROIS'.
    * - for generating applications like LIS and CO-PA, the generic table
    *   E_T_DATA has to be used.
    * Only one of these interface types should be implemented in one API !
        FETCH NEXT CURSOR g_cursor
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE e_t_DATA
                   PACKAGE SIZE l_maxsize.
        IF sy-subrc <> 0.
          CLOSE CURSOR g_cursor.
    *      bice_trace_close g_r_tracer.
          RAISE no_more_data.
        ENDIF.
    *    bice_collect_table g_r_tracer e_t_data.
        g_counter_datapakid = g_counter_datapakid + 1.
      ENDIF.              "Initialization mode or data extraction ?
    ENDFUNCTION.
    in the above I_t_fields and I_T_select structures  are not getting data .....
    can any one pleasee let me know what mistake i hvae done with my code?
    and i m unbale to change data source value to F1 if i am trying to change my function module and extract structure are disappearing....
    i m not getting why it is happening .......
    thank you
    vijay

    Hi yasemin,
       I m bit confused here with the line below
                                     IF i_initflag = sbiwa_c_flag_on.(if we pass 'X' then it will enter loop and checks for F or D and then assigns values to I_T_SELECT and I_T_Fields structure)
          accordfing to my code i feel it will work for any one not both(F or D).
    one more doubt rsax_biw_get_data extraction method is F2 few of them are asking to change to F1.
    so tried running a code then in RSO2 extact structure and FM both dissapeared i did not get why it happened ?
    can you please let me know why it happend
    thanks
    vijay

  • Calling a Selection Screen from a Function Module/Method

    Hi,
      I would like to call a selection screen from a function module or method. I understand it is not possible by the definition. Are there any alternative options as I am looking for the Variants Save option on the screen. Any thoughts?
    Thanks
    Raghav

    Since i don't know your exact requirements (standard SAP selection screen? your own selection screen?) the onl;y thing i can come up with is:
    1. in your function pool create your own screen with a subscreen area
    2. create your own selection screen as a subscreen.
    3. include the selection subscreen in the first screen
    4. call the first screen in your function.

  • Issue with function module HR_INFOTYPE_OPERATION in badi HRPAD00INFTY

    Hello All,
    I have a business scenario wherein, when user saves data for infotype 0002 from tcode PA30, i have create a new record for infotype 0105 by copying existing record and just changing the date.
    For the same I am using funtion module HR_INFOTYPE_OPERATION inside badi HRPAD00INFTY method AFTER_INPUT.
    When I am running the same function module in a independent program, its running fine. But when I run it inside the badi method, it runs with sy-subrc = 0 and no error, but later in the standard program MP000200,in pai module PRE_INPUT_CHECK, it tries to execute this statement     MOVE <namst> TO <subty> and gives dump, with runtime error MOVE_TO_LIT_NOTALLOWED_NODATA and saying that "Error at assignment: Overwritten protected field.".
    Have tried all the options of function module HR_INFOTYPE_OPERATION, but nothing is helping.
    Kindly let me know if any information on the same.
    Best Regards,
    Rahul Malani

    Have you checked what's in the Subtype field of table T777D for infotype 0002?
      IF t777d-namst ne space.                                  "QNOK025939
        MOVE <namst> TO <subty>.
      ENDIF.
    Usually this sentence won't be executed unless there is something in that field. Usually we don't have subtypes for IT0002.
    Also make sure that the infotype that gives the dump is 0002 and not 0105.
    Regards.

Maybe you are looking for

  • Ipod won't sync with windows 8

    The Ipod connects and shows up in iTunes (yes latest version) but I can't sync - it's grayed out. For some reason all the songs on the Ipod are not also present on the computer. The original computer the iPod was set up on was a Vista machine. It die

  • HT201210 I am stuck with "The iPad could not be restored because the firmware file was corrupt" message.

    Hi I have an iPad mini and it was on iOS 6.1.3, my friend came and he said that he knows how to install iOS 7 for me. I gave it to him and he tried to install it, but apparently he failed to do so and an "Activation Error" is appearing on the screen

  • Is it possible to cancel a Goods Receipt?

    Hi everybody. I use SAP B1 2008. I know we can cancel certain documents in SAP after they have been posted. Ex. We can cancel a Sales Order by Selecting Data -> Cancel from the menu. Is it possible to cancel a posted Goods Receipt (or a Goods Issue)?

  • IMac or macbook pro? for architecture

    Study architecture and work with autocad and 3dmax (and other Autodesk products), I want to know whether an iMac or MacBook Pro these programs work without problems, because most tells me it's much better version in the window, I saw another option f

  • Nikeplus site leaderboard not working

    As of today, when I log in to the nikeplus site and go to the Community/Leaderboard area, my rank is not shown at all and I can't get any valid 'week' data (the first time the site shows no data and if I then switch to 'month' and then back to 'week'