Converting Eth port to FC port in a cisco 6001 switch

Hi,
Back to forum after a long time. I have one issue to discuss regarding cisco 6001 switch. We purchased a new 6001 switch. Want to convert some of the Ethernet ports out of total 48 to FC to join the switch into a existing fabric.
cisco Nexus 6001 Chassis ("Norcal 64 Supervisor")  - This is what H/W version look like from show version command.
In the past, we have quite a few Cisco 5548UP switch and the way convert the Ethernet port into FC port is, by going to correct slot/module and then
(config)# slot 1
(config-slot)# port 41-48 type fc
Then "reload" willl complete the conversion. But in the new 6001 switch, it throws the following error when above command is typed. We have full license for the switch including  FC_FEATURES_PKG
"ERROR: Module type doesn't support this CLI"
We are running firmware : 6.0(2)N2(2)
Any help in this regard will be helpful.
Thanks.

I have this exact same error;
 show ver
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
Copyright (c) 2002-2014, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
Software
  BIOS:      version 1.5.0
  loader:    version N/A
  kickstart: version 7.0(5)N1(1)
  system:    version 7.0(5)N1(1)
  Power Sequencer Firmware:
             Module 1: version v4.0
             Module 2: version v4.0
  Fabric Power Sequencer Firmware: Module 1: version v4.0
  Microcontroller Firmware:        version v1.2.0.5
  QSFP Microcontroller Firmware:
             Module 2: v1.3.0.0
  SFP Microcontroller Firmware:
             Module 1: v1.1.0.0
  BIOS compile time:       12/29/2012
  kickstart image file is: bootflash:///n6000-uk9-kickstart.7.0.5.N1.1.bin
  kickstart compile time:  10/29/2014 22:00:00 [10/30/2014 11:46:56]
  system image file is:    bootflash:///n6000-uk9.7.0.5.N1.1.bin
  system compile time:     10/29/2014 22:00:00 [10/30/2014 11:47:58]
Hardware
  cisco Nexus 6001 Chassis ("Nexus 64 Supervisor")
  Intel(R) Xeon(R) CPU  @ 2.00 with 8238120 kB of memory.
  Processor Board ID FOC181506P3
  Device name: xxxxxxxxxxxxxx
  bootflash:    7823360 kB
Kernel uptime is 3 day(s), 17 hour(s), 25 minute(s), 49 second(s)
Last reset at 642096 usecs after  Fri Feb 27 15:24:40 2015
  Reason: Disruptive upgrade
  System version: 6.0(2)N2(3)
  Service:
plugin
  Core Plugin, Ethernet Plugin, Fc Plugin
xxxxxx# conf t
Enter configuration commands, one per line.  End with CNTL/Z.
xxxxxx(config)# slot 1
xxxxxx# port 47-48 type fc
ERROR: Module type doesn't support this CLI

Similar Messages

  • Node port number :This port is in use.Select another port number-

    I am trying to insalled Informatica 9.0.1 Hotfix2 on my personal laptop and getting below error and was getting same error for 8.6.1, Si i have uninstalled it
    Node port number :This port is in use.Select another port number
    I have tried passing different no like 6005,6006,6007,6008.... but for all it giving me the same error.
    Can any please answer where i can check that which port system is using and what the available values?
    OS: Windows 7 Professional
    DB:Oracle11g

    Hi,
    Goto start > run > enter netstat -o command and execute it and it will display all the addresses. In Foreign Address column the entire ipaddress:portnumber will be display and along with this process id(pid) will be displayed. Check whether the portnumbers are being used by any other application or it is in blocked state. If it is in blocked state then kill that process id with taskkill /pid /f command at command prompt.
    After doing this you can try to install it one more and let us know whether it got succeeded or not.
    Thanks,
    Navin Kumar Bolla

  • "in port" and "out port" VIs are not in the functions palette!

    Hi,
    I am using LabVIEW 2012 on a Win 7 64 bit. I want to read a digital input (3.5V) using PC parallel port. I also read this white paper:
    http://digital.ni.com/public.nsf/allkb/B937AC4D8664E37886257206000551CB
    I searched all the functions palette for “in port” and “out port” VIs but I could not find them. Apparently they are not supported in 64bit OS. What are my alternatives for reading digital input via PC parallel port?
    Thanks.

    They have not been supported for quite some time. What happens when you use the recommended VISA api?

  • Any Mini Display Port to Display Port cable?

    I am going to buy a new 30" DELL monitor which equipped with Display Port, but I cannot find any Mini Display Port to Display Port cable, so what can I do?
    Don't tell me to buy a Mini Display Port to Dual Link DVI cable, it is nonsense to change the type of connector and buy that expensive cable.

    There is at least one that I know of.
    http://estore.circuitassembly.com/products/Mini-Displayport-to-Displayport-Adapt er-Cable.html
    I have it and am doing with it exactly what you want to do and it's working great.

  • VIZIO blu-ray internet player won't connect, needs Port 43 or Port 80?

    I have WRT54G router.  The VIZIO VBR231 unit finds the network OK and indicates it is connected, but nothing will stream, and  when I run a Network Test it gives me this 3 line error:
    Connection to 0.0.0.0... successfully established
    Resolving... could not be established
    Please check your connection and try again.
    The VIZIO support folks were not helpful at all, and said something about Port 80 or Port 43 not being open or available.  When I talked to linksys support, they said I needed to add the VIZIO player's IP (which appears to be 0.0.0.0 in the system settings).  Can anyone tell me what I would need to do, step by step?  I poked around a bit, including the Port Forwarding tab on the router setup, but could not see a way to assign 0.0.0.0 to one of these ports, and I am hesitant to experiment.
    I'll probably just return the unit to Costco, but I'm trying this forum as a last ditch effort.  BTW I have a VIZIO internet TV that I love, and that had absolutely no problem at all connecting to the wireless.  Thank you!

    If your other devices are able to connect to the wireless network then I think the router is working fine.
    The IP address on Blu-ray is 0.0.0.0 which is not a valid IP address.
    Make sure that Blu ray is not set to a static IP address with the blank fields. Set the Blu ray to obtain IP address from the router.
    Or Blu ray is not getting IP address from the router.
    Open the setup page of the router and go wireless tab. Click on wireless security sub tab and check the wireless security settings. Make sure that you have the correct network key for your wireless network.
    Click on wireless MAC filter sub tab. It should be disabled.
    Try to connect to the wireless network on Blu ray again and see if that works.

  • HT201300 You have Macbook of some kind and it has two Thunderbolt ports.  Which port do you use first for an external monitor/projector?

    You have Macbook of some kind and it has two Thunderbolt ports.  Which port do you use first for an external monitor/projector?

    By the way, I have tried shutting of the display switching in the power settings.  That was basically the only real answer I found anywhere.  It didn't work.

  • W510 Docked in 433820U Port Replicator USB Ports Occassiona​lly Stop Working

    Has anyone had the problem where the USB ports on the 433820U Port Replicator stop working? I've had it happen on several occassion where the USB ports on the port replicator stop working when I do something seemingly unrelated (e.g. unplugging a CAT5 network cable, dropping something on the desk near the docked laptop). Once this happens, I have to unplug the USB devices from the port replicator and plug them into the laptop's USB ports in order to continue using the keyboard or mouse, or turn the laptop off and then back on. I'm trying to figure out if this is a defect in the port replicator or some outdated driver. Anyone else have a similar problem?

     This system supports USB3 ports but they are only USB2 on the port replicator. What's up with that?
    Hi William:
    I kinda, sorta think that the reason that the USB connectors on the Dock are only USB2 has to do with the speed of the connection between the big dock connector on the bottom of the notebook and the USB ports on the back of the Dock.
    I notice a similar problem when I had a W500 and a earlier model Dock.  That earlier model dock had an UltraBay in it.  If I put a hard drive (installed in a caddy) in the Dock, it ran very slowly - as if it was connected by USB - but if I put the same hard drive in the same caddy into the UltraBay on the side of the W500, it ran very, very fast.  So, all I could attribute this to was that the data just could not flow through the dock connector on the bottom of the notebook as fast as it could flow through the UltraBay connector on the inside of the notebook.
    Perhaps the same concept applies to the USB connectors on the Dock... maybe the USB3 connectors on the notebook itself have a faster data connection into the computer than the USB connectors on the dock, which need to pass through that big dock connector on their way to the computer.
    Michael
    W520 (4270 CTO), which replaced a W500 (4062-27U), which replaced a T42P, which replaced an A21P...

  • How to revert p4 port and telnet port from 50204 to default?

    Hi,
    i changed the p4 port and telenet port to 50204 using Visual Administrator. Now Visual Administrator and the J2EE server are both down. Is there some way I could revert back my ports to the default ports?
    Also, my J2EE dispatcher process is down with an exit code of -11113. Could someone let me know how to change the port settings for telnet and p4 please?

    Hi,
    You can do this through "ConfigTool". It is a offline tool and comes handy when JAVA system is down. It requires only database up.
    Start configtool.ba from the directory "<Drive>:\usr\sap\<SID>/JC01\j2ee\configtool.
    Then select the node Cluster Data->Instance_<No.>->Dispatcher_ID<No.>->
    1). P4->Local Properties
    In the port you have to mention 5<instance no.>04
    if you instance number is 01 then it should be 50104
    2). telnet->Local Properties
    in the port you have to mention 5<instance no.>08
    if your instance number is 01 then you have to mention 50108.
    Then try to restart the JAVA system.
    Best regards,
    sheo

  • Port Forwarding with Port Translation RV042, RV016, RV082

    This is a feature request for the Linksys RV series Routers.  Currently, it appears that the Cisco/Linksys RV042, RV082, and RV016 only support port forwarding and 1-to-1 Nat.  One item that I find very helpful with customers is port forwarding with port translation.  I am requesting that this feature be included with a future firmware relase for these RV series routers.
    Here is an example of the request.
    Take an incoming service request on a TCP or UDP destination port and forward it to an internal IP on a different TCP or UDP port.  For example, customer A wants to allow different machines on the internal network to receive Windows RDP connections inbound.  To make PC maintenance identical between the internal machines, the customer does not want to change the listening port for RDP on the individual PC workstations through the Windows Registry.  The customer also does not want to dedicate separate IP's to each machine in a 1-to-1 NAT setup.  The only option is to have remote connections to each of these PC's to use a different destination port.  So, for example, PC one could be reached on TCP port 5151, PC two on TCP port 5152, and PC three on port 5153.  This requres a firewall that is able to translate each of these connection requests to a different internal IP on the default RDP port (TCP 3389).  So, the following setup is required:
    Port Forwarding with Port Translation:
    Router External IP on TCP port 5151 ---> forwarded to PC One's internal IP on TCP 3389
    Router External IP on TCP port 5152 ---> forwarded to PC Two's internal IP on TCP 3389
    Router External IP on TCP port 5153 ---> forwarded to PC Three's internal IP on TCP 3389
    There are several comparable "small business" class router competitors to the RV042, RV082, and RV016 that will perform this port forwarding with port translation process without incident.  Unfortunately, these Cisco/Linksys small business routers will not accomplish this task currently.
    Please implement this feature in a future firmware release.
    Thanks!

    Excellent.  I see this now.  None of our customers actually use the UPNP feature, so we never realized that Port Forwarding with Port Translation features existed on this page along with the ability to enable or disable UPNP.
    Perhaps, in the future, this functionality could be moved to and incorporated into the port forwarding page which seems to be a more logical location.
    In either case I'm very happy to know that this feature is available on the RV's.
    Thanks for your assistance.

  • DIO Port Config & DIO Port Write Block Diagram Errors (Call Library Function Node:libra​ry not found or failed to load)

    Hi Guys, need help on this.
    I have this LabVIEW program that used to work on the old computer.
    The old computer crashes most of the time, so I upgraded the computer
    and used its Hard Drive as slave to the new computer.
    I have no idea where are its installers since the guy that made the program 
    is not in my department anymore.
    I downloaded all the drivers needed from NI: NIDAQ9.0, NIVISA,NI488.2, 
    and drivers of some instruments needed in the setup. I'm using LabVIEW8.2.
    Everything's fine until I open the LabVIEW program for our testing.
    Here goes the error:
       DIO Port Config
       DIO Port Write
    Block Diagram Errors
       Call Library Function Node: library not found or failed to load
    Attachments:
    ErrorList.JPG ‏200 KB

    Honestly, I'm a newbie on Labview. I just want this old program to run on the new computer.
    The guys that installed the drivers on the old computer are no longer here in my department.
    And I have no idea where the drivers are. So I just downloaded the drivers needed for my hardware and instruments.
    Here's my hardware: (cards: PCI-DIO-96, PCI-GPIB), (instruments: SCB100,E4407B, HP83623, HP3458, HP8657)
    OS: Windows XP Pro
    By the way, I have unzipped the TraditionalDAQ drivers. First I tried the 7.4.1, but installation error appeared.
    I thought maybe the installer is corrupted, so I downloaded the 7.4.4 and unzipped it.
    But, still same installation error appears. I don't understand, both TraditionalDAQ drivers have same installation error.
    Now I have tried the DAQmx8.7.2 driver, bu still the DIO Port Config and DIO Port Write have errors.

  • CER Use port description as port location

    Hello all,
    I am trying to confirm if this "feature" is as useless as I have found it to be. From my testing and what little documentation I can find when checking the "Use port description as port location" check box on the LAN switch details screen this will ONLY show you this information when looking at the switch port details screen. It DOES NOT actually use the switch port description as location information for the 911 call notifications. 
    My hope was that by checking this check box the switch port description would override the ALI location information configured within the ERL assigned to the switch port that the phone is connected to. This would allow the creation of one ERL/ALI per building say and the device specific room level information would simply come from the switch port description. With out this option a ERL/ALI has to be created for every room in the building. 
    Thank you all.

    There's absolutely no problem in choosing 8888 as admin port while installing IWS in solaris Environment. Just make sure u follow these steps while installation:
    (1)You should choose a random number for the administration server to make it harder for anyone to breach your server.
    (2) Make sure the port you choose isn't in use. Look at the file /etc/services on the server machine to make sure you don't assign a port number that is reserved for another service. If you choose a port that is being used by another service, the installation program prompts you for another port.
    (3)Note :If you choose a server port number lower than 1024, you must be logged in as root to start the server. After the server is bound to the port, the server changes from the root user account to the user account you specify. If you choose a port number greater than 1024, you don't have to be the root user to start the server.
    Regards
    T.Raghulan

  • Can I use "accesshw.zip" to make the in port and out port VIs work (for NT) for Labview 6.0.2.

    I am trying to write to the parallel port using labview 6.0.2 (vi attatched). It does not seem to be working with NT though it does with Win 98.
    The information about the software (accesshw.zip)mentions versions 4.x and 5.x only.
    Please refer to the link given below:
    http://zone.ni.com/devzone/explprog.nsf/6c163603265406328625682a006ed37d/49664743ded6f1da862564bc004e3a7f?OpenDocument
    thanks.
    Pari.

    Hi Rob,
    I cannot completely agree..... Please find attached a
    accesshw_lv6.llb. Originally it was made for LV5; now in LV6-version) This .llb contains accesshw-files for use under NT & W2k. These files work, if you store them (!! including the sub.vi's !!) into: C:\Program Files\National Instruments\LabVIEW 6\vi.lib\platform\system.llb (this should be the typical path). The "old" In Port and Out Port vi's have to be substituted. Find in addition a simple test-program for use with scope in order to test
    the execution speed / toggeling of bits.....see the scope-picture copied into diagram. In addition I strictly recommend the use of buffer-circuits in order not to destroy the mainboard-IC's by accident. If somebody needs schematics or programs rela
    ted to parallel port - example see jpeg-file please mail to: [email protected]
    regards
    wha
    Attachments:
    accesshw_lv6.llb ‏171 KB
    printer_port_test.llb ‏135 KB
    8255_diagram.jpg ‏186 KB

  • After change port for TCPIP PORT for default SQL Server instance (MSSQLSERVER), sql service and sql agent service did not started again

    Hi 
    -when i install default instance MSSQLSERVER i added a domain account as a service account,
    - when i change port for TCPIP PORT , and after sql service and sql agent service did not started again.
    it thrown error 
    The SQL Server (MSSQLSERVER) service failed to start due to the following error: 
    The service did not start due to a logon failure.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Service Control Manager" Guid="{555908d1-a6d7-4695-8e1e-26931d2012f4}" EventSourceName="Service Control Manager" />
        <EventID Qualifiers="49152">7000</EventID>
        <Version>0</Version>
        <Level>2</Level>
        <Task>0</Task>
        <Opcode>0</Opcode>
    but when i add domain\sqservice account in administrators group these services started,
    1) here  why this change behavior  happened
    2i changed the port 1500
    adil

    HI
    the sql instance service is running with domain/sqlservice account , 
    - i stopped the sql service service
    - when i start it not started again and i found below error message
    Domain and account: MOJPORTAL\spsqlservice
    This service account does not have the required user right "Log on as a service."
    User Action
    Assign "Log on as a service" to the service account on this computer. You can use Local Security Settings (Secpol.msc) to do this.
     If this computer is a node in a cluster, check that this user right is assigned to the Cluster service account on all nodes in the cluster.
    If you have already assigned this user right to the service account, and the user right appears to be removed, 
    check with your domain administrator to find out if a Group Policy object associated with this node might be removing the right.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Service Control Manager" Guid="{555908d1-a6d7-4695-8e1e-26931d2012f4}" EventSourceName="Service Control Manager" />
        <EventID Qualifiers="49152">7041</EventID>
        <Version>0</Version>
        <Level>2</Level>
        <Task>0</Task>
        <Opcode>0</Opcode>
        <Keywords>0x8080000000000000</Keywords>
        <TimeCreated SystemTime="2015-04-24T17:12:58.326973300Z" />
        <EventRecordID>2177</EventRecordID>
        <Correlation />
        <Execution ProcessID="520" ThreadID="4044" />
        <Channel>System</Channel>
        <Computer>PORTALSQL1.mojportal.com</Computer>
        <Security />
      </System>
      <EventData>
        <Data Name="param1">MSSQL$xSQL</Data>
        <Data Name="param2">xxxL\spsqlservice</Data>
      </EventData>
    </Event>
    adil

  • Port 81 and port 441

    Experts:
    It's said that port 81 can somehow mapped to 441.
    I have searched the web but found no info about this.
    Is there any relation between the 2?
    Thanks!

    Hi,
    Your question is not clear. If you want to redirect requests coming on port 81 to port 441 then it is possible. You can check below link for the same:
    http://help.sap.com/saphelp_nw04s/helpdata/en/00/040f3a39ce8704e10000000a114084/content.htm
    Thanks
    Sunny

  • How can I mirror all ports on CISCO 3750 switches to one Gigabyte port?

    Hi,
    I have a requirement to mirror all the ports on my 7 CISCO 3750 switches, which are in 3 separate stacks, to one single Gigabyte Ethernet port.
    Does anyone know how I can do that?
    Thanks in advance.

    Vlad, thanks a heap for your response.
    I want to apply to my sitation. Please let me know if I get them right in the following:
    Catalyst A
    vlan 901
    remote-span
    monitor session 1 source interface fastethernet 1-48 (I want to monitor all ports on the CISCO 3725)
    monitor session 1 destination remote vlan 901
    Catalyst B
    vlan 901
    remote-span (If I don't need to monitor this switch, do I still need to put anything into this switch at all?)
    Catalyst C
    vlan 901
    remote-span
    monitor session 1 source interface fastethernet 1-48 (I want to monitor all ports on this switch as well)
    monitor session 1 source remote vlan 901
    monitor session 1 destination interface gigabitethernet 3 (There are 4 Gigabit Ethernet Uplink in CISCO 3750, I want all the traffic to go to port 3, is this the right way to do?)
    Thanks in advance.

Maybe you are looking for

  • Have lost original iTunes music files on my MacBook Air

    Hi, can someone help? My purchased music files are no more aviailible on my mac, probably i have deleted them. Although on iTunes they are indicated under "purchased" but unfortunately I cannot access them. The list of music albums and songs still is

  • How can I map a network drive on an iPad once a VPN is established?

    I have a new iPad and I am trying to access a network drive once I establish a VPN on my company's network. I can establish the VPN, but I am not sure of how to map a network drive like I do on my MacBook using smb.

  • "Statement is not accessible." - Error

    Hi, am working for an ECC upgradation project and am getting the above error "Statement is not accessible." at the below coding. WS_VBELN = XLIPS-VBELN. Kindly get me a solution <removed by moderator> Thanks in adv, Siva Edited by: Mike Pokraka on Se

  • Balance Sheet Crystal report

    Hi, Can we call a crystal report (Layout) on Balance Sheet form by taking the Date parameter??? Regards, Amrut Sabnis

  • Safari 5 Crashes all time when i write something on the toolbar