Converting Nexus 2000 FEX from Single Homed to Multihomed

Greetings!
I have a 2248TP FEX and two 5548UP Nexi.  Yesterday, one of the 5548s experienced an issue that caused it to go offline.  The FEX is single-homed to that 5548, and so everything connected to it went offline as well.
I want to multihome the FEX to both 5548s to avoid future outages to the FEX should one 5548 go offline.  However, I am aware that both 5548s must have identical configuration for the FEX.  Will multihoming it cause the FEX to stop operating because 5548 #2 will come up with no configuration for the FEX?  I do not have the 5548s doing any configuration sharing, they are separately configured.
I am on NXOS version 6.0(2)N2(4).
Thank you!
Henry

Hi Henry,
Before you do anything, you need to configure your 5548 switches with VPC.  You need to have one or 2 connections between the 5548s and configure them as VPC peer-link.  You also need to configure the out of band management port on each switch as your VPC peer keep-alive.
Once all the VPC configs are complete, you can connect your FEXs to both 5ks and create a VPC for each one.
Please refer to this document for config example:
http://www.cisco.com/c/dam/en/us/td/docs/switches/datacenter/sw/design/vpc_design/vpc_best_practices_design_guide.pdf
HTH

Similar Messages

  • Question re. behaviour of single homed FEX with vPC

    Hi Folks,
    I have been looking at configuring Nexus 5Ks with FEX modules.  Referring to the Cisco documentation;
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/layer2/513_n1_1/b_Cisco_n5k_layer2_config_gd_rel_513_N1_1_chapter_01001.html
    In figure 3. showing a single homed FEX with vPC topology, I'm curious what happens if one of the 5Ks fail.  For example if the 5K on the left hand side of the diagram fails do the ports on the attached FEX that the server is attached to drop? If not I would assume that the server has no way of knowing that there is no longer a valid path through those links and will continue to use them?
    Many thanks in advance,
    Shane.

    Hello Shane.
    Depending of type of the failureboth n5k can tace corrective actions and end host will always know that one of the port-channel members is down.
    For example if one 5k will crash or will be reloaded - all connected fexes alre will go offline. FEX are not standalone switches and cannot work without "master" switch.
    Also links which will go from fex to the end-host will be in vpc mode which means that all vpc redundancy features/advantages will be present.
    HTH,
    Alex 

  • Convert from Single Org to Multi-Org

    Hi All,
    Can someone tell me what are the steps to convert from Single Org to Multi-Org ?
    Is it only the profile value 'MO: Operating Unit' to be setup ? or any other steps to be setup ?
    Regards
    Jhansi

    Jhansi,
    Please see the following:
    Note 259546.1 - Setting Up Multiple Organizations in Oracle HRMS
    Regards,
    Greg

  • Converting to Oracle Real Application Clusters from Single-Instance Oracle

    Is there any notes at metalink for
    Converting to Oracle Real Application Clusters from Single-Instance Oracle Databases
    We should have 10g DB on ASM to make it RAC?

    With Oracle Database 10g Release 2, $ORACLE_HOME/bin/rconfig tool can be used to convert Single instance database to RAC. This tool takes in a xml input file and convert the Single Instance database whose information is provided in the xml. You can run this tool in "verify only" mode prior to performing actual conversion. This is documented in the RAC admin book and a sample xml can be found $ORACLE_HOME/assistants/rconfig/sampleXMLs/ConvertToRAC.xml. Grid Control 10g Release 2 provides a easy to use wizard to perform this function.

  • Single Homed or Dual Homed FEX

    With the ability to do enhanced VPCs now on the FEXs is there any benefit to have a mixture of having of single attached FEXs and dual homed FEXs?
    Here are some benefits as I see them
    Single homed FEX is easier to trouble shoot as the topology is not as complex.
    A dual homed FEX will support both dual attached hosts and a single attached host. So this means we only have one topology to deal with (everything dual homed)
    Any other pros or cons?         
    Thanks

    If you have any servers with only one uplink, you want dual homed FEXes for redundancy.
    Also, it depend on the number of FEXes you are connecting to the same set of switches.  For example: the max number of FEXes that can be uplinked to a set of 6k switches is 24 if you are dual homed, but if you are single homed the max is 48 (24 per switch).
    HTH

  • Converting from single episodes to seasons

    What happened to episodes already purchased when you convert from single downloads to buy a whole season? Dop you get credits for the episodes you purchased before iTunes offeres up the series as a single purchase?

    It's not a true conversion problem that you have but more a space problem. Tables columns are created by default with the init. parameter NLS_LENGTH_SEMANTICS character semantics:
    If NLS_LENGTH_SEMANTICS = BYTE
    then 1 character = 1 byte whatever the db character set
    If NLS_LENGTH_SEMANTICS = CHAR
    then 1 character = 1 character size for the db character set.
    If this parameter is changed it is only taken into account for newly created tables or columns: existing columns are not changed.
    See http://download-uk.oracle.com/docs/cd/B10501_01/server.920/a96529/ch2.htm#104327
    The only solution I see is to enlarge your VARCHAR2 columns before running the import...
    Message was edited by:
    Pierre Forstmann

  • Nexus 2K FEX dual-homed to two Nexus 5K Configuration

    Hi.
    I am trying to look for Nexus 5K config when the nexus2K FEX is dual-homed into it.
    What will be the configuration on both 5K especiall the pinning?
    Assuming one N2K 10G port is connected to N5K-1 and another N2K 10G port connected to N5K-2?
    N5Ks are also configured as dual-sided vpc with two N7K.
    thanks

    N5k-1 ====vpc peer==== N5k-2
    \  E1/10                     E1/10  /
          \      Fex-100           /
    N5k-1 & N5k-2 config:
    ===============
    Interface po100
    switchport mode fex-fabric
    fex associat 100
    vpc 100
    int e1/10
    switchport mode fex-fabric
    channel-group 100

  • Nexus 5548 SPAN Destination- Dual Homed FEX

    I understand that order to setup a SPAN monitor session, only 5K local ports can be destination ports.  Our FEX are dual homed, so I know we have to have the monitor session configured on both 5K's.  We are wanting to connect an Infinistream sniffer to the destination port.  What I am confused about is do we also have to have 2 destination ports, one on each 5K connecting to the Infinsitream or can we just use one?

    You cannot set more than one destination to a monitor session.  You can have multiple source interfaces, but only one destination.  Try this:
    destination interface e2/14
    You will need to create two more separate monitoring session with the same source interfaces but set the destination to the other two interfaces.
    HQ-N5k-2(config-if-range)# monitor session 1
    HQ-N5k-2(config-monitor)# source interface e1/17 both
    HQ-N5k-2(config-monitor)# destination interface e2/14
    HQ-N5k-2(config-if-range)# monitor session 2
    HQ-N5k-2(config-monitor)# source interface e1/17 both
    HQ-N5k-2(config-monitor)# destination interface e2/15
    HQ-N5k-2(config-if-range)# monitor session 3
    HQ-N5k-2(config-monitor)# source interface e1/17 both
    HQ-N5k-2(config-monitor)# destination interface e2/16
    Please rate if helpful

  • Vlan Filter between Nexus 2000 / 3750-X

    Dear all,
    I have 2 Cisco Nexus 5000 with each 2 Nexus 2000 in FEX Mode. My Vlan are all in fabric mode.
    I would tried to connect a catalyst 3750-X and a nexus 2K together in trunk with filter vlan.
    NEXUS 2000 <== Port-Channel ===> Cisco 3750X
    N2K :
    Po: switchport mode trunk
          switchport trunk allowed vlan 10,20,30
    Interface  : e101/1/1 & e102/1/1
                     switchport mode trunk
                    channel-group 1 mode active
    3750X
    Po : switchport mode trunk
          switchport trunk allowed vlan 10,20,30
          spanning-tree bpdufilter enable
    interfaces : Gi0/1 & Gi0/2
            switchport mode trunk
            switchport trunk allowed vlan 10,20,30
            channel-group 1 mode active
    It doesn't work in allowed vlan (not connection, nothing all) but without the command allowed vlan, my po and my interfaces are up. I tried wihtout LACP in mode etherchannel only but it was the same result.
    Questions :
    - Could you tell me if this a mechanism with the fabric mode or if there is something to add or modify ?
    -  If I have a VLAN 40 from my 3750X but not in the 2K, it is forwarding accross my interface ?
    Thanks for your help.
    Have a nice day,
    Matthieu

    Hi,
    The 2ks are desihned for connecting end devices e.g servers, workstations, etc.. to the network and not connecting other switches to it.  You can however connect your 3750X to both 5ks using vPC.
    from the config guide:
    Any device running spanning tree connected to a Fabric Extender host interface results in that host
    interface being placed in an error-disabled state when a BPDU is received.
    link
    http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus2000/sw/configuration/guide/rel_6_0/b_Configuring_the_Cisco_Nexus_2000_Series_Fabric_Extender_rel_6_0.pdf
    HTH

  • Nexus 5548 fex interface configuration in vPC scenario

    Hello Forum Team!
    I have a pair of Nexus 5548UP configured as a vPC domain active-standby couple with six Nexus 2248TP Fex's in a dual-homed scenario (each fex is connected to each 5548UP). At the same time, both 5548UP are dual-homed to a pair of VSS Catalyst 6509.
    I have a couple of questions regarding performance and configuration:
    1. When configuring a fex interface, I've noticed that if the configuration is not the same or replicated on both 5548UP, the fex interface won't come up; is this normal behaviour? For now I am replicating manually the configuration on both 5548UP (not confyg-sync).
    2. When performing ICMP tests from the 2248TP to the VSS, the response time is around 1ms to 2ms; from the 5548UP to the VSS pair is approximately 0.5ms. Is that normal delay response time from the 2248TP? I was expecting less response time from the 2248TP (the fex's have 20 Gigs of uplink bandwidth to the 5548UP pair and the 5548UP pair have 40 gig's of bandwidth to the VSS pair).
    Thanks in advanced team!

    Hi,
    1. When configuring a fex interface, I've noticed that if the configuration is not the same or replicated on both 5548UP, the fex interface won't come up; is this normal behaviour?
    Yes, that is a normal behavior.  Since yours FEXes are connected to BOTH 5ks, you have to configure both 5Ks in order for the FEX to come up. If you connect your FEX physically to only one 5k, then you only configurethat one 5k, but in your case you need to configure both 5ks exactly the same.
    2. When performing ICMP tests from the 2248TP to the VSS, the response time is around 1ms to 2ms; from the 5548UP to the VSS pair is approximately 0.5ms. Is that normal delay response time from the 2248TP? I was expecting less response time from the 2248TP (the fex's have 20 Gigs of uplink bandwidth to the 5548UP pair and the 5548UP pair have 40 gig's of bandwidth to the VSS pair).
    I have never tested this, but I would think since the 2k needs to to 5k for every packet including talking to another host on the same 2k, the delay would slightly be higher then when you ping directly from the 5k.
    HTH

  • Convert list item attachment from docx to pdf using Word Automation Services

    I have been trying to convert List Item attachments from docx to pdf using word automation services, it works in a normal document library but when I use the list attachment it throws a null reference error.
    var settings = new ConversionJobSettings();
    settings.OutputFormat = Microsoft.Office.Word.Server.Conversions.SaveFormat.PDF;
    var conversion = new ConversionJob("Word Automation Services", settings);
    conversion.UserToken = SPContext.Current.Site.UserToken;
    var wordFile = SPContext.Current.Site.RootWeb.Url + "/" + wordForm.Url;
    var pdfFile = wordFile.Replace(".docx", ".pdf");
    conversion.AddFile(wordFile, pdfFile);
    conversion.Start();
    Using reflector I was able to see my problem lies in Microsoft.Office.Word.Server.FolderIterator.cs where it uses SPFile.Item which returns NULL
    internal void CheckSingleItem(SPFile inputFile, SPFile outputFile)
    Microsoft.Office.Word.Server.Log.TraceTag(0x67337931, Microsoft.Office.Word.Server.Log.Category.ObjectModel, Microsoft.Office.Word.Server.Log.Level.Verbose, "OM: FolderIterator start a single item: source='{0}'; dest='{1}'", new object[] { inputFile.Url, outputFile.Url });
    Stopwatch stopwatch = Microsoft.Office.Word.Server.Log.StartPerfStopwatch();
    try
    this.CheckInputFile(inputFile.Item);
    this.CheckOutputFile(outputFile.Url);
    Is there any way to get around this?

    Hi Qfroth,
    According to your description, my understanding is that when you use word automation service to convert Word to PDF for list item attachment, it throws the null reference error.
    I suggest you can create an event receiver and convert the word to memory stream like below:
    private byte[] ConvertWordToPDF(SPFile spFile, SPUserToken usrToken)
    byte[] result = null;
    try
    using (Stream read = spFile.OpenBinaryStream())
    using (MemoryStream write = new MemoryStream())
    // Initialise Word Automation Service
    SyncConverter sc = new SyncConverter(WORD_AUTOMATION_SERVICE);
    sc.UserToken = usrToken;
    sc.Settings.UpdateFields = true;
    sc.Settings.OutputFormat = SaveFormat.PDF;
    // Convert to PDF
    ConversionItemInfo info = sc.Convert(read, write);
    if (info.Succeeded)
    result = write.ToArray();
    catch (Exception ex)
    // Do your error management here.
    return result;
    Here is a detailed code demo for your reference:
    Word to PDF Conversion using Word Automation Service
    Best Regards
    Zhengyu Guo
    TechNet Community Support

  • How do I convert emails to PDF from Outlook to make a file on the PC?

    how do I convert emails to PDF from Outlook to make a file on the PC

    It is always tough for anyone when we need to save our emails into one file for future reference. You could either do it manually or can use a simple tool to Convert all your messages into one pdf file . This Single pdf file can be used if we need to read any past email. you can easily convert oulook to pdf in no time. If you are converting several email messages, you can either save them as separate files with initial layout fully intact or combine them into one big PDF document.

  • Dell Servers with Nexus 7000 + Nexus 2000 extenders

    << Original post by smunzani. Answered by Robert. Moving from Document section to Discussions>>
    Team,
    I would like to use some of the existing Dell Servers for new network design of Nexus 7000 + Nexus 2000 extenders. What are my options for FEC to the hosts? All references of M81KR I found on CCO are related to UCS product only.
    What's best option for following setup?
    N7K(Aggregation Layer) -- N2K(Extenders) -- Dell servers
    Need 10G to the servers due to dense population of the VMs. The customer is not up for dumping recently purchased dell boxes in favor of UCS. Customer VMware license is Enterprise Edition.
    Thanks in advance.

    To answer your question, the M81KR-VIC is a Mezz card for UCS blades only.  For Cisco rack there is a PCIe version which is called the P81.  These are both made for Cisco servers only due to the integration with server management and virtual interface functionality.
    http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/data_sheet_c78-558230.html
    More information on it here:
    Regards,
    Robert

  • How to convert select-options table into single field internal table

    Hi,
    My requirement is to convert select-options table into single internal table which has one field.
    e.g. select-options: s_matnr for mara-matnr.
           select-options table can have options  'BT',"EQ", "NE", "GE", "GT", "LE", "LT", "CP" etc. select-options table
           have   Sign:I ,Option:BT, Low: 1, High.10.The new internal table records should be 1,2,3,4,5,6,7,8,9,10.
    Please suggest any function module available for this scenario in SAP.
    Thanks,
    Somi.
    Edited by: somi reddy satti on Sep 15, 2009 3:18 PM

    Hi Sowmya,
    Here is the answer if I understand well of your question.
    Data: begin of gt_mon OCCURS 0,
                  mon(2)             TYPE n,
             end of gt_mon.
    Data: begin of gt_year OCCURS 0,
                  year(4)             TYPE n,
             end of gt_year.
    Select-options: s_period       FOR ptdw_pws_db-kmonth NO-EXTENSION
                                                                                    DEFAULT sy-datum(6)
                                                                                    TO sy-datum(6).
    For example according to above statement period is 201110 is 201201.
    Period field does n't exists in SAP for selection. If your selection is on date based on period which is given on the selection-screen then you need to convert the period to date by concatenating ( or using FM to convert )01 at the end of each period . You need to declare one range table for date to select the data from table.
    loop at s_period.
    gr_date-sign   = s_period-sign.
    gr_date-option = s_period-option.
    COncatenate s_period-low
                          '01'
    into gr_date-high.
    COncatenate s_period-high                   
                           '01'
    into gr_date-low
    append gr_date.                      
    ENDloop.
    Thanks,
    Satheesh

  • Convert smartform to pdf from ABAP webdynpro

    Hi,
    I want to convert smartform to pdf from ABAP webdynpro and
    I want to display pdf in ABAP wedynpro view or portal iview.
    what are the steps needs to be followed?
    what are the classes and interfaces needs to be used?

    Hi,
    Please check this it might be useful.
    Data: tab_otf_data    type  ssfcrescl,
             wa_out_opt      type  ssfcompop,
             wa_con_params   type  ssfctrlop.
              wa_rspoid       type  rspoid,
    parameter:p_file like rlgrap-filename no-display.
    Follow control parameters
           wa_out_opt-tdimmed = 'X'.
             wa_out_opt-tdnewid = 'X'
            wa_con_params-no_dialog = 'X '.
    if you want print direct  pass
            wa_out_opt-tddest  = 'printer' (SAP Printer)
    If you are using multiple header records  use loop other wise no need
       note that when multple headers
      pass count and count > 1 means more than one header change control parameters to create single spool for all.
    Loop itabXXXX.                                      " multiple header starts
      count = count + 1.
          if count > 1.
            wa_con_params-no_open = ' '.
            wa_out_opt-tdnewid = ' '.
          endif.                                               " multiple header ends
    call function  fm_name
            exporting
              control_parameters = wa_con_params
              output_options     = wa_out_opt
              header_header      = wa_ven
            importing
              job_output_info    = tab_otf_data
            tables
              header_details     = itab_final
            exceptions
              formatting_error   = 1
              internal_error     = 2
              send_error         = 3
              user_canceled      = 4
              others             = 5.
             at last.                                                         " multiple header starts
            wa_con_params-no_close = ' '.
            wa_con_params-no_dialog = 'X'.
          endat.                                                           " multiple header ends
    endloop.
    you will get  the otf data and spool id from  'tab_otf_data'
    read table tab_otf_data-spoolids index 1 into wa_rspoid.  " Now you get spool no in wa_rspoid.
    " pass spool in to rstxpdft4 it converts to pdf".
    submit rstxpdft4
               with spoolno = wa_rspoid
               with p_file = p_file
               and return.
    I feel that your problem will solve....
    Thanks,
    Hari

Maybe you are looking for

  • BT Cloud wont upload Large Files

    Hi New to the forum so please be nice! Ive recently started to use my BT cloud storage and today increased my storage to 50GB. I have a few files i want to upload that are over 2GB in size each, so i set about setting the upload via the PC client app

  • Primavera Project Planner 3.1 Installation on Windows 7

    I'm having trouble installing project planner 3.1 on windows 7 it says " the version of this file is not compatible with the version of windows you are running. check your computer systems information to see whether you need you need an X86 (32bit) o

  • ERROR:max no of 100 conversations exceeded

    Dear All, I m tring to comfigure SAP XI(2004sr2) in 2nd step of SLD system : Connect SLD TO SEN (if CEN Present). I m getting following error Element 'BAPI_SLD_SUPPLIER_CONFIG_SET':Connect to SAP gateway failed Connect_PM  TYPE=A ASHOST=XIDEV SYSNR=0

  • Function module equivalent to SWE_EVENT_CREATE while using ABAP classes

    Hi there, I used to use SWE_CREATE_EVENT to fire the events linked to my BOR objects, in order to start certain workflows. Now I am using ABAP classes within the WorkFlows, and the name of the classes MUST (in my case) be longer than 10 characters, a

  • How to set a single tab in JTabbedPane invisible

    Hello, I want to set only a single tab invisible out of 9 tabs in JTabbedPane. I can disable the tab but not able to set invisible. Thanking you in advance.