Copy of standard network

Hi Friends,
I am trying to copy standard network template in CN01 but all activities are coming by default, I want to remove the activities but when i try to delete them I am getting message CP654- You can only select created records.
Kindly help.
Thanks & Regards
Bhairavi

Hi Ammar,
Thanks for your reply.
I tried that also. When I use copy function all the activities which are present come in my network as gray out & remaining one come in normal mode. When I remove WBS assigned to these from total tab& then try to delete i am able to do so but still it doesnt get updated.
Forexample, In the network template 730 activities are there in primary costs tab . These gets copied in gray out , but rest i.e.740 onwards are copied & these I want to delete , but system is not allowing me to do so. i am using CN02.
After removing WBS , I am able to delete but its not getting saved.
In create std network option, all the activities are coming & these are also i am not able to delete.
Kindly help.
Thanks & Regards
bhairavi

Similar Messages

  • PS Module: Function to Copy Standard Network

    Hi,
    Anybody knows of a function where I can copy values of a standard network in Project Systems module?

    I'm not a ABAPer but I'll suggest you to debug the program SAPLCOKO and look at the functional modules (Function groups) that are involved.
    Mentioned program belongs to Transaction CN41 -Create Network where you can create a network copying a standard network.
    Hope this helps!
    Regards
    Sreenivas
    Pls close the post if satisfied.

  • PS creating Opertive Network from Standard network, need to copy user field

    Hello All,
       has anyone tried to create Opertive Network(cn21) with reference to a  Standard network. what we need to do is from the first line line item copy 3 user defined fields from the User Fields tab on the Standard Network to the header of the Opertaive Network and then on the additional fields tab put those 3 values. 
    I have look at the User Exits and i am now looking into the BOR.
               thanks scott

    Hi Prasad,
    Have a look at OSS Note 95024. Hope this note provides some inputs.
    Thanks
    Lakshman

  • How to create and use templete or standard network / activity and wbs

    dear
    i have define the structure for my project which have WBS elements, network and activties. the strucutre is same for all the projects that i define.
    i wanna know whether to use templete or standard wbs network and activities as templete for the project.
    for a network there are almost 150 activties across 10 wbs elements i want this structure as a templete what can i do create it.
    Further, how can i use LSMW to create relationship for ativities?
    regards
    saqib usman

    I have create std wbs level 1 5 wbs further i create std nwrk and activities and assignMENT are as follows
    h1.*Create std wbs from CJ91 *
    STD DEFINITION IS
    E00-BSS-CO-BTS-0000              STANDARD BTS
    LEVEL 1 WBS ELEMENTS
    E00.BSS.CO.BTS.0000.RFP     RADIO FREQUENCY PLANNING
    E00.BSS.CO.BTS.0000.SA     SITE ACQUISITION
    E00.BSS.CO.BTS.0000.TXN     TRANSMISSION
    E00.BSS.CO.BTS.0000.CW     CIVIL WORKS
    E00.BSS.CO.BTS.0000.PMO     PMO
    RELEASE THE STD PROJECT OPTIONAL BY EDIT > STATUS > RELEASE
    h1.CREATE STD NETWORK FORM "CN01" tcode
    NEWORK HEADER WITH FOLLOWING SETTING
    9000000    STD NETWORK CORPORATE BTS 0001
    Network usage     UNIVERSAL
    Planner group   1      1
    Network status     RELEASE (GENERAL)
    Std.WBS element     E00.BSS.CO.BTS.0000.BSS
    Predefined plnt      CO01
    press activity overview button or (shiFt+F7)
    I ASSIGN ACTIVITY TO STD WBS ELEMENTS
    ACTIVITY    OPR. SHORT DESC  STD WBS ELEMENT
    A01            ZERO VERIFICATION   E00.BSS.CO.BTS.0000.RFP
    A02            DESIGN DOCUMENT   E00.BSS.CO.BTS.0000.RFP
    B01            SITE SURVEY 1          E00.BSS.CO.BTS.0000.SA
    B02            SITE SURVEY 2          E00.BSS.CO.BTS.0000.SA
    C01            CIR Doc Input              E00.BSS.CO.BTS.0000.CW
    C02            CIR CW Input by RM    E00.BSS.CO.BTS.0000.CW
    D01            CIR Doc Input              E00.BSS.CO.BTS.0000.TXN
    D02            CIR TXN Input by RM    E00.BSS.CO.BTS.0000.TXN
    E01            Rollout Month               E00.BSS.CO.BTS.0000.PMO
    E02            ON Air Date                 E00.BSS.CO.BTS.0000.PMO
    h1.PREREQUISITE FOR ASSIGNMENT OF STD NETWORK and WBS are:
    PROCESS TRANSACTION "CJ20N" TO INCLUDE STD NETWORK ALONG WITH ASSIGNED ACTIVITIES AND STD WBS.
    FURTHER, I WANT TO COPY STD NTWORK SEVERAL TIMES with different network number. EACH TIME I COPY STD NWK TO OPERATIVE STRUCTURE THE SYSTEM SHOULD PROMPT NEW NUMBER FOR NETWORK AND ALSO PROMPT TO ENER ASSIGNED STD WBS ELEMENTS WITH REPLACE OPTION for operative WBS NUMBER.
    STANDARD WBS                                               OPERATIVE WBS
    E00.BSS.CO.BTS.0000.RFP     REPLACE BY     E00.BSS.CO.BTS.0003.RFP
    E00.BSS.CO.BTS.0000.SA     REPLACE BY     E00.BSS.CO.BTS.0003.SA
    E00.BSS.CO.BTS.0000.TXN     REPLACE BY     E00.BSS.CO.BTS.0003.TXN
    E00.BSS.CO.BTS.0000.CW     REPLACE BY     E00.BSS.CO.BTS.0003.CW
    E00.BSS.CO.BTS.0000.PMO     REPLACE BY     E00.BSS.CO.BTS.0003.PMO
    IN MY OPERATIVE STRUCTURE
    I HAVE TWO LEVEL FOR WBS I.E.:
    E00.C0.BSS            LEVEL 1
         E00.BSS.CO.BTS.0001    LEVEL 2    ASSIGNED NWK  0001 WITH ACTIVITIES AND WBS
         E00.BSS.CO.BTS.0002    LEVEL 2    ASSIGNED NWK  0001 WITH ACTIVITIES AND WBS
         E00.BSS.CO.BTS.0003    LEVEL 2    WHERE I WANT TO ASSIGN STD NWK AND WBS
                                                                  (I HAVE CREATED EXTERNAL NUMBER FOR NETWORK)
    I GO TO THE TEMPLETE AREA AND CLICK ON STD NETWORK BUTTON AND DRAG STD NETWORK 09000001-1 TO E00.BSS.CO.BTS.0003. ENTER NAME FOR NETWORK "BTS 0003". SYSTEM PROMPT TO ENTER EXTERNAL NETWORK NUMBER I.E.
    Enter network number
    WBS elem:E00.BSS.CO.BTS.0003
    Copy from network:
    E00-BTS-0003
    h1.CLICK CONTINUE BUTTON  NOW REAL PROBLUM COMES A DIALOG BOX APPEARS
    Include standard network
    You want to include a standard network that has assignments to standard WBS elements. However, the selected WBS element does not correspond to the standard WBS element.
                   Copy Assignment                            Ignore Assignment
    In case, if i select button Copy assignment or select Ignore Assignment then:
    New network created E00-BTS-0003 under WBS     E00.BSS.CO.BTS.0003 with all assigned activitites but no WBS elements i.e.
    STANDARD WBS                                               OPERATIVE WBS
    E00.BSS.CO.BTS.0000.RFP     REPLACE BY     E00.BSS.CO.BTS.0003.RFP
    E00.BSS.CO.BTS.0000.SA     REPLACE BY     E00.BSS.CO.BTS.0003.SA
    E00.BSS.CO.BTS.0000.TXN     REPLACE BY     E00.BSS.CO.BTS.0003.TXN
    E00.BSS.CO.BTS.0000.CW     REPLACE BY     E00.BSS.CO.BTS.0003.CW
    E00.BSS.CO.BTS.0000.PMO     REPLACE BY     E00.BSS.CO.BTS.0003.PMO
    After all my finding i am not able to bring activity assigned WBS elements. Kindly help and provide information to resolve the problum.

  • Releasing standard network automatically when integrated in released proj.

    Hi Guys,
    I am facing the following problem:
    In the PS module we have created several Def/WBS standard structures with NW and activities.
    Once we have copied the standard template in a new operative structure, we add some new standard networks and rebuild the structure in order to fulfil the new operative project needs. Once done we release the project definition in order to release all objects in the projects, i.e. WBS, Networks, activities and material.
    For some reasons and after the releasing phase we have to had new standard networks somewhere in the project structure on WBS level.
    The problem we face then is that the new network and all the related activities do not get the release status as all other objects but still remain in the open status. How is it possible to set automatically the release status in the new network, as far as the project definition is released?
    Thank in advance for your precious inputs/solutions.
    Best regards

    Hi Pierre,
    Check the option in OPSC to release the networks immediately after the creation. This will release the networks as soon as they are created.
    Hope this helps you.
    Regards
    K Ramaiah

  • Standard network assigning various WBS Elements

    Hi,
    I am using Standard network and Stand WBS Element for creating actual project.
    There are Std WBS Elements, using the same Standard network. As i know, we can assign Std WBS Element in Std network. How can i make it using same std network for various Std wbs element to create actual project as Std network is same for most of the WBS Elements.
    I donot want to copy Std network for actual project once we create copying Std Project in CJ20N.
    Regards
    N.Raju

    create more standard wbs - there is no other way

  • Standard network not creating project and WBS automatically

    Hi,
    I have a standard network with a standard WBS assignment at BOTH header and activity levels.
    I created a link to a material in CN08 with this standard network.
    Assembly processing has been configured.
    When creating a sales order, entering the material... the network create screen appears and the system requests a WBS element.
    At this point the system should have created the WBS element.
    When I insert an existing active WBS element as a test..., the system message indicates that the network is already assigned to a Std WBS element.
    Why is the system not using this assignment to create a project and WBS element form the standard structure?
    Thanks

    Hi,
    As a test...
    I've removed the linking of the material and standard network in CN08 - and the system now displayed a screen asking for standard network details.
    I create the material and standard network link again in CN08 - and I'm back to the original issue of the network create screen appearing, but the WBS field is blank. The system is not generating the WBS.
    So - the system is recognizing the link of the material entered in the sales order and the standard network via CN08. But its not using the Standard WBS used in the standard network AND CN08 setup....
    Note: The Std WBS has the planning and  billing indicator ticked.
    Once again, when creating the sales order, I get the network create screen asking for a WBS element. If I insert an existing WBS element I get the message below. The issue is - I know the standard WBS assignment exists, why isn't the system generating a new operative WBS at this point?
    An assignment to a standard WBS element already exists
    Message no. CN044
    Diagnosis
    You have created a network by copying from a standard network. The standard network is assigned to a standard WBS.
    However, at the same time, you have made your own assignments to WBS elements.
    System Response
    When you manually make assignments to WBS elements, the system does not necessarily take the asignments in the standard stuctures into account.
    Procedure
    When you call up the function replace standard WBS or when you save the network you decide whether the manually created WBS assignments or those fronm the standard structures are copied.

  • How to standard network / activity and std wbs to operative project

    dear all,
    i want to include a standard network that has assignments to standard WBS elements. However, to assign std network from templete area i got dialog box (include standard nework) which contains:
    (You want to include a standard network that has assignments to standard WBS elements. However, the selected WBS element does not correspond to the standard WBS element.)
    in below the above message there are 2 button i.e.
    1. Copy Assignment
    2. Ignore Assignment
    in both the above button selection i am not able to bring assigned (std WBSe).
    After all my finding i am not able to bring activity assigned WBS elements. Kindly help and provide information to resolve the problum.
    saqib usman

    done

  • Report to check Standard WBS link to which standard network and activity

    Dear All,
    Is there any way or standard report to check standard WBS (cj93) link to standard network/activity (CN03).
    Normally we create project by using template existing, we would like to check the structure. Is there any way to check the standard template for it ( WBS template link to network/activity template).
    Thank you.
    Nies

    Hi,
    Please try this:
    1. Tcode : CN41
    2. Change database profile: In that in the origin check mark the Standard structure. Continue..
    3. At the bottom of the selection screen check mark the standard structures.
    4. In the selction area for the Project hit F4 and  select the project based on the standard WBS Element.
    5. Exceute the report.
    Hope this is useful.
    Reward points if found useful.
    thanks..

  • Problem in copying a standard maintenance view

    Hi to all experts,
    My requirement is to make an exact replica of the standard view   V_T71ADM23 . I have copied the view into a custom z view and in the table maintenance generator created a function module and provided a screen . but the screens in both standard and custom view which i have generated is different. So i copied the standard function group in the table maintenance generator of the standard view into a zfunction group and assigned to the custom view . If i do that im getting errors like
    View C_V_T71ADM21 has no active version and no entry in the control directory
    View VT71ADM19 has no active version and no entry in the control directory
    View VT71ADM20 has no active version and no entry in the control directory
    View VT71ADM21 has no active version and no entry in the control directory
    View VT71ADM22 has no active version and no entry in the control  directory
    View VT71ADM23 has no active version and no entry in the control directory

    Hi venkat ,
    i followed your procedure but it is the same . Im getting different screens  for standard and one which i copied . what could be the reason
    after going into sm30 click maintain entries
    give compensation area and
            guideline matrix
    hit enter
    i tried with both standard and custom
    the screens are different in standard and custom some fields are missing in the custom view which i copied
    Please help . greatly appreciated .....

  • Problem in copying a standard function module!

    Hello there,
                     I need to copy the FM, RS_TABLE_LIST_DISPLAY, to a Y function Module. But I am not able to copy it as a single FM, I have copy all the FMs in that function group i.e. SETB.
                     I, then copied that standard function group SETB. I am getting a strange error message while activating the copied version. The error which I am getting is:
    The parameter "INTTAB" of the global interface has already been defined outside the function.
    INITTAB is some defined internal table.
    Also the include in which this error is getting appeared is LY.....$07 something. I have tried to many times. Not able to resolve the issue.
    Please help!
    Regards,
    Ganesh Khumse

    Hi There,
                  Thanks for your reply. I have not defined anything in the copied function module. I just copied and tried to activate it, error occurred.
    Thanks & Regards,
    Ganesh Khumse

  • Error in standard network creation using BAPI

    hi,
    I need to create standard network using BAPI.
    I am trying with BAPI_BUS2002_CREATE. As per the documentation, I need to call function BAPI_PS_INITIALIZATION. But, I am not able to get the required output since its giving me error.
    Does anybody has used the same BAPI for standard network creation.
    Regards,
    Ujjwala

    HI,
            How did u create standard network? If u used bapi, which bapi did u use???

  • Uploading Standard Networks (tr. CN01) using LSMW

    Dear colleagues!
    I've recently faced a problem trying to craete LSMW project for uploading Standard Networks to the system.
    Once the Object 170 (Routing), Method 0002 (Direct input) has been chosen for the Standard Batch/Direct Input in step 1 and everything else has also been prepaired for uploading (steps 2-12), while processing the step 13 LSMW says that "Transaction CN01 doesn't exist".
    At the same time thist Object 170 and Method are valid for, for example, PP's transaction CA01 (also a route).
    What might this error message coused by?
    Or probably sombody could recommend some other effecient method for mass uploading Sdandard Networks to the System?
    Thank everybody in advance,
    Regards, Anton.

    Thanks for answering, but this decision seems to be quite tricky and non-trivial. Probably some more convenient and easy variants? -)

  • Problem in Sapscript , After creating a copy of Standard Script

    Hello friends,
                       I have copied a standard script WASCHEIN into ZWASCHEIN, now all the data is coming from driver program SAPM07DR. Now there is one field which is not coming from the standard program,
                      Is there any way i can capture the field in my script without making changes in the standard driver program like a select statement in the script.
    Thanks.
    Edited by: Vijay Babu Dudla on Dec 16, 2008 3:24 AM

    Hello Poonam,
    Sorry i think you are not aware of using PERFORM stmts in SAPScripts !!!
    @ Amit you can try this bit of coding:
    /:           PERFORM F_GET_KTEXT IN PROGRAM ZPROGRAM
    /:           USING &MSEG-NPLNR&
    /:           CHANGING &V_KTEXT&
    /:           ENDPERFORM
    Create a Subroutine-Pool Program: ZPROGRAM where you write the FORM for the above PERFORM.
    FORM f_get_cust_details
    TABLES fp_it_input  STRUCTURE itcsy
                  fp_it_output STRUCTURE itcsy.
    DATA:
      l_v_nplnr TYPE nplnr,
      l_v_ktext TYPE auftext. 
      READ TABLE fp_it_input WITH KEY name = 'MSEG-NPLNR'.
      IF sy-subrc = 0.
        l_v_nplnr = fp_it_input-value.
      ENDIF.
      SELECT SINGLE KTEXT
      INTO l_v_ktext
      FROM aufk
      WHERE aufnr = l_v_nplnr.
      LOOP AT fp_it_output.                                     "#EC *
        IF fp_it_output-name EQ 'V_KTEXT'.
    *     Modifying the output table with the customer number
          fp_it_output-value = l_v_nplnr.
          MODIFY fp_it_output.
      ENDLOOP.
    ENDFORM.
    Please note that passing the USING / CHANGING parameters through tables of ITCSY structures is a standard way of doing this & you cannot change this )
    Hope this helps.
    BR,
    Suhas
    Edited by: Suhas Saha on Dec 16, 2008 9:39 AM

  • In the past, I have had no problem copying from a network HDD to my Mac.  Recently, I cannot copy and get error code 8084.  Any thoughts?

    I cannot copy from my network drive to my iMac; I get error code 8084.  I can copy the same material from my network drive to my PC.  In the past, I have had no troubl copying to my iMac. What happened-going from OS 10.6.7 to 10.6.8?

    Thread bump.

Maybe you are looking for