Create Footprint with custom pad has solder mask issue

Ultiboard 12 (12.0.653)
When I create a new footprint with normal pads, everything works fine. When I add a custom pad to the footprint or make the footprint with all custom pads, the solder mask does not work correctly.
The attached photo of the Footprint edit mode pad 1.jpg shows 16 standard pads along with three custom pads. The solder mask layer is turned on along with the Copper top layer. All pins should be the same light color. The custom pads are purple. (When you first create the footprint they are green instead of purple).
When a part is placed on the board there is a solder mask shown for all pins like pad2.jpg. If you turn off the solder mask layer the normal pins appear green but the custom pins disappear as shown in pad 3.jpg.
To get around this problem I edited the part in the data base by turning off the soldermask check box for each custom pad pin, then manually created a mask on the solder mask layer for each custom pin.
These custom pads are new pads just created and old custom pads known to work in previous ultiboard versions.
I didn't see any similar messages in the forum. Is this a known issue?
Michael
Attachments:
Pad 1.jpg ‏53 KB
pad 2.jpg ‏39 KB
Pad 3.jpg ‏44 KB

Hi Michael,
I was able to replicate this problem, Ultiboard doesn't want to place solder mask on the bottom layer and on top solder mask, and you have to play around with the pad settings to turn on the solder mask.  I will let the developers know about this problem. To work around this issue, you can do following:
1.  Make the solder top or bottom the active layer in the Design Toolbox and then select Place>>Graphics, manually draw the soldermask over your custom pad.
2.  If your custom pad is an odd shape and you don't want to redraw it, you can create a component with only one custom pad.  Save the component and then place the component on the work area by itself. Next select File>>Export>>DXF, export just the copper top layer.  Now, create your component and before exiting Footprint Edit mode, select File>>Import>>DXF, merge the DXF you generated to the solder mask top and bottom. When you imported the DXF file, there may be several independent objects and you can’t move them together.  In this case, create a window around the DXF data you just imported and then select Edit>>Group Selection to group the DXF data as one object now you can move everything at the same time.  
Tien P.
National Instruments

Similar Messages

  • Profit Center Disabled while Creating Material with Custom Trnx

    Hi all,
    I am trying to extend material to a another Plant with Custom trnx to create material.
    I am able to create / extend material for some plants. But, for few plants, I am getting error to input data for 'Profit' Center' field in 'Sales:General / Plant' view' as 'MARC-PRCTR' is not ready for input. The field is in disable (grayed out) mode. But, for other materials, I am able to extend the material successfully.
    The Profit center value is same which used for previous materials, extended successfully. Except the target Plant , all the details are same.
    Coudl some one can help on this.
    Regards
    SP

    this is most probably because of missing customizing of field selection in OMS9 transaction

  • HP Pavilion Slimline s5-1126 with 2 monitors has screen resolution issue

    I have 2 HP Pavilion Slimline s5-1126 PC with HP 2031 dual monitors on each computer. Both computers were first started with only 1 monitor and everything worked great. I have now added a second monitor to the DVI output on each and the monitors on both systems connected to the DVI don't display correctly. I checked the display settings and the number 1 monitor said PnP Generic Monitor and number 2 monitor said HP 2031. I did a detect on the display and it did not change. I switched the monitors and the monitor connected to the DVI is still incorrect. There is no option to change the resolution either on the number 1 monitor. It appears to me that it just does not recognize the monitor. The strange thing is that both computers are doing this. I set an identical system up last week and it worked great. Any help will be great

    @Clay...
    Please read the info at this other post; New HP Pavilion PC Can't Change Monitor Resolution. The common thread here, seems to be AMD Hudson Socket FM1 systems using DVI (digital) output with 20" LCD monitors.  And your setup falls into this category.
    Frank
    Frank
    {------------ Please click the "White Kudos" Thumbs Up to say THANKS for helping.
    Please click the "Accept As Solution" on my post, if my assistance has solved your issue. ------------V
    This is a user supported forum. I am a volunteer and I don't work for HP.
    HP 15t-j100 (on loan from HP)
    HP 13 Split x2 (on loan from HP)
    HP Slate8 Pro (on loan from HP)
    HP a1632x - Windows 7, 4GB RAM, AMD Radeon HD 6450
    HP p6130y - Windows 7, 8GB RAM, AMD Radeon HD 6450
    HP p6320y - Windows 7, 8GB RAM, NVIDIA GT 240
    HP p7-1026 - Windows 7, 6GB RAM, AMD Radeon HD 6450
    HP p6787c - Windows 7, 8GB RAM, NVIDIA GT 240

  • Create Downloadlink with custom blob to start other Application

    Greetings!
    We are using Apex 4.2.1 and another system. For this other system you can use simple files with an id, that start it and open a specific page, same way like e.g. automatically opening ms-word, when downloading a .doc file.
    So we would like to have a column in an APEX-report, that has this download functionality. I have read throu How to convert varchar to BLOB in oracle 10g? and took a look at this APEX tutorial and a Blog from Eddie Awad.
    But still I cant get it to work.
    For testing purposes I have created a table with a blob column, and a procedure, like the one in the APEX tutorial.
    When I call the procedure like in that example#OWNER#.download_my_file?p_file=#ID#I get the error message: The requested URL /pls/prod/(our owner).download_my_file?p_file was not found on this server. Maybe it does not work with the server setup we are running, or needs some adjustments?
    Also as mentioned by Eddie Awad, that APEX supports BLOB columns in reports, doesnt work for me. The column output (both IR and classic) is "unsupported Datatype".
    Can you help me with any advice in this matter?
    Thanks very much in advance,
    best regards,
    tobi

    Hi PARS,
    thanks for the link.
    I followed the example, looks like a nice approach, but I cant get it to work.
    I created the procedure, the non-public the Page-0 process(On Load:Before Header), the app-item, and a link with the url as described in that example. But when linking, I get the error ORA-01403: No Data found. The process is not executed.
    I think I can solve it with the APEX-buildin BLOB download feature in an IR - i have firuged it our now. But using a procedure would still be a much better solution.
    edit:
    Hi Mike,
    thanks for your hints. I have included a propper filename and mimetype in the table. However, if I use a table to open the blob, that would have to be filled beforehand and joined to the other report. So using a procedure on another page would still be better. I will try later again to get that to work.
    So far, thanks for your help,
    tobi
    Edited by: TobiP on 05.06.2013 07:31

  • Can't create LOM with Custom Marker

    Is there a way to create a List of Markers with a custom marker? For example, I created a marker named Warning and another one named Caution. I want to create a LOM for each of these. But when I try to add a LOM in the book, those markers are not options, only the system markers.
    I'm using FM 9.
    Thanks,
    Karen

    Karen,
    I use FrameMaker 9. The List of Custom Markers AND the Index of Custom Markers both work for me. The only difference is that I am using structured FrameMaker, but it would think it should work in unstructured FM.
    Maybe others might know what else you need to do to make it work.
    One guess is that your new marker types need to be imported into all the files in the book, possibly the book itself. I do not know how they are stored. Maybe they are variable definitions or maybe document properties, but I am just guessing.
    Van

  • Create Folder with custom FolderClass (string)

    Hi, 
    When creating a new folder, how does one set the FolderClass (IPF.XXXXX) string inside Outlook?
    Similar to following using EWS
    var f = new Folder(_svc);
    f.FolderClass = "IPF.Note.ITQ.Custom";
    The closest to FolderClass string I could find is, DefaultMessageClass property, but its read-only.

    Try to set the PR_CONTAINER_CLASS property (DASL name http://schemas.microsoft.com/mapi/proptag/0x3613001F) using MAPIFolder.PropertyAccessor.SetProperty.
    Dmitry Streblechenko (MVP)
    http://www.dimastr.com/redemption
    Redemption - what the Outlook
    Object Model should have been
    Version 5.5 is now available!

  • Inactive Customer Report/ Customer who has done transaction

    Hi All.
    I need to created report for customer who has done any transaction in last 2 years, please suggest me way to achieve this
    Thanks
    Prem

    Hi ,
    which is the Idea given by our collegue it is ok,
    But there you can keep all the objects data.
    so you can try in this way
    take the info object ( ocustomer) and take the cube ( where you are getting the transactional daat of that customers)
    keep left side the 0customer object and right side info cube and create teh infoset with left outer  join
    here you can get the all the customer detials based on the masetr data , and which are c ustomers are done business for thenm transactional data will come.
    now in query where the  value <0 condtion , you can keep , it shows onle who are not done businees .
    Thansk & Regarsd,
    sathish

  • Problem when creating Database with Database, OS and hardware Configuraiton

    Problem when creating Database:
    There are two problems, which I faced during creation of database. When creating database with Oracle Database Assistant. One when creating pre tuned database from CD. And second when creating customized database giving options your self.
    Problem # 1:
    When creating pre tuned database from CD. The process of creating Database is 90 % complete and is at step # 3 Initializing Database. It gives error ORA-03113: end-of-file on communication channel.
    I searched following oracle help for this problem.
    ORA-03113: end-of-file on communication channel
    Cause: An unexpected end-of-file was processed on the communication channel. The problem could not be handled by the Net8, two-task software. This message could occur if the shadow two-task process associated with a Net8 connect has terminated abnormally, or if there is a physical failure of the interprocess communication vehicle, that is, the network or server machine went down.
    Action: If this message occurs during a connection attempt, check the setup files for the appropriate Net8 driver and confirm Net8 software is correctly installed on the server. If the message occurs after a connection is well established, and the error is not due to a physical failure, check if a trace file was generated on the server at failure time. Existence of a trace file may suggest an Oracle internal error that requires the assistance of customer support.
    Conclusion:
    What I conceive from this problem and the help available is that, I have to install NET8 again. But I am not sure about the solution, please tell me whether I am rite or not.
    Problem # 2:
    When creating database with custom option. The process of creating Database is 2 % complete and is at step # 2 Creating Database Files. It gives error ORA-12571: TNS:packet writer failure.
    I searched following oracle help for this problem.
    ORA-12571: TNS:packet writer failure
    Cause: An error occurred during a data send.
    Action: Not normally visible to the user. For further details, turn on tracing and re-execute the operation. If error persists, contact Worldwide Customer Support.
    Conclusion:
    What I conceive from this problem and the help available is that, I have to install NET8 again. But I am not sure about the solution, please tell me whether I am rite or not.
    Software & Hardware Configuration are as follow:
    Software:
    Database
    Oracle 8.1.7.0.0 (Oracle8i)
    Operating System
    Microsoft Windows 2000
    5.00.2195
    Service Pack 2
    Hardware:
    x86 Family 6 Model 8 stepping
    10
    AT/AT COMPITABLE
    260,400 KB RAM

    user563502 wrote:
    I am working on Solaris 8. What is Alert_SID.log? where can I find it?
    ThanksFor the responsible of the upgrade of Oracle database, not even know what Alert log is?
    to be honest with you, this is not your work.

  • Refresh combobox with custom display(Plug in)

    Hello ,
    I am using combobox with custom display(Plug in) in my application.
    i want to display value in combobox on selection of values in radio item
    sample query used in combobox like
    if :Radio_item = 1 then
    return 'SELECT NAME dropdown_display
        ,NAME search_string
        ,NAME input_display
        ,id return_value
    FROM Table_A';
    else
    return 'SELECT NAME dropdown_display
        ,NAME search_string
        ,NAME input_display
        ,id return_value
    FROM Table_B';
    end if;
    but problem is it is always showing the data from first query,it is not displaying the value from second query on changing of radio option.
    i also tried to refresh the combobox item  on change of radio item values but still it is showing the value from first query.
    please help me how to resolve this issue.
    Apex Version - 4.1.1
    Database - 11g
    Regards and thanks
    Jitendra

    Shiv wrote:
    Hi,
    I used plugin "Combobox with Custom Display".
    I have issue like
    When i entered some text in textbox and scroll down using down key of key board. That highlighted part can not scroll down with scroll.
    The demo link for above issue
    http://apex.oracle.com/pls/apex/f?p=35538:4
    kindly help me out.
    ThanksIts a bug in the plugin code and not related to APEX.
    I will look into it and fix my code to address this issue, please bookmark this page http://www.apex-plugin.com/oracle-apex-plugins/item-plugin/combobox-with-custom-display_212.html and check for updates.
    Thanks,
    Vikram

  • How to Create a multiefield in CQ with custom type?

    Please can anyone guide me to create a multiefield component with custom xtypes...

    Hi Karthi,
    Bellow you find some example code for custom multifield
    * @class CQ.wcm.QuestionsBlock
    * @extends CQ.form.CompositeField
    * The filter rule field lets the user select "include" or "exclude" and enter a regexp
    * @constructor
    * Creates a new QuestionsBlock.
    * @param {Object} config The config object
    CQ.wcm.QuestionsBlock = CQ.Ext.extend(CQ.form.CompositeField, {
         * @private
         * @type CQ.Ext.form.TextField
        hiddenField: null,
         * @private
         * @type CQ.Ext.form.TextField
        questionsblocktitle: null,
         * @private
         * @type CQ.Ext.form.NumberField
        questionsnumber: null,
        constructor: function(config) {
            var formCfg = {"trackLabels":true,"type":"form"};
            config = config || { };
            var defaults = {
                    "border": true,
                    "layout":  formCfg,
                    "padding": "7px",
                    "stateful": false,
                    "autoWidth": true,
                    "align": "left"
            config = CQ.Util.applyDefaults(config, defaults);
            CQ.wcm.QuestionsBlock.superclass.constructor.call(this, config);
        // overriding CQ.Ext.Component#initComponent
        initComponent: function() {
            CQ.wcm.QuestionsBlock.superclass.initComponent.call(this);
            this.hiddenField = new CQ.Ext.form.Hidden({
                "name": this.name,
                "stateful": false
            this.add(this.hiddenField);
            this.questionsblocktitle= new CQ.Ext.form.TextField({
                "fieldLabel": "Question Block Title",
                "allowBlank":false,
                "stateful": false,
                "mode": 'local',
                "name": 'questionsblocktitle',
                "width": '230px',
                'labelStyle': 'width:120px;'
            this.add(this.questionsblocktitle);
            this.questionsnumber= new CQ.Ext.form.NumberField({
                "fieldLabel": "Question Number",
                "stateful": false,
                "allowBlank":false,
                "mode": 'local',
                "name": 'questionsnumber',
                'labelStyle': 'width:120px;',
                "width": '230px'
            this.add(this.questionsnumber);
        // overriding CQ.form.CompositeField#setValue
        setValue: function(value) {
            var vArray = value.split(";");
            this.questionsblocktitle.setValue(vArray[0]);
            this.questionsnumber.setValue(vArray[1]);
        // overriding CQ.form.CompositeField#getValue
        getValue: function() {
            return this.getRawValue();
        // overriding CQ.form.CompositeField#getRawValue
        getRawValue: function() {
            var questionsblocktitle= this.questionsblocktitle.getValue();
            var questionsnumber= this.questionsnumber.getValue();
            var value = questionsblocktitle+ ";" + questionsnumber;
            this.hiddenField.setValue(value);
            return value;
         * Loads the options of the selection if an optionsProvider is available.
         * This method is usually called solely by {@link CQ.Dialog} after its
         * content has been loaded.
         * @param {String} path content path (optional)
         * @private
        processPath: function(path) {
            var dialogPath = this.findParentByType("dialog").path;
            this.doLayout();
    // register xtype
    CQ.Ext.reg('questionsblock', CQ.wcm.QuestionsBlock);
    Regards,
    kasq

  • Creating a new project with custom fields using web services

    I've been trying unsuccessfully for the last week or so to successfully create a new project from web services and I believe the main problem that I've been running into is that one of the required fields is a custom field. I've tried creating the Project
    in a couple of different ways and haven't had any success up to this point, so any help would be appreciated. I've tried creating it with both a REST call to /_api/ProjectServer/Projects and a SOAP call to /_vti_bin/PSI/Project.asmx. Below are the best shots
    I've made at the two different calls with the errors I received. If anyone has any leads on the best way to do this the help would be appreciated!
    REST POST /_api/ProjectServer/Projects
    'odata.type' : 'PS.PublishedProject',
    'Name' : 'OData Name',
    'Custom_9d77d62aa92e4d40adc8446c90eb7456' : "O&M"
    Response
    error: {
    code: "11713, Microsoft.ProjectServer.PJClientCallableException"
    message: {
    lang: "en-US"
    value: "PJClientCallableException: CustomFieldRequiredValueNotProvided CustomFieldRequiredValueNotProvided mdpropuid = 9d77d62a-a92e-4d40-adc8-446c90eb7456"
    SOAP POST /_vti_bin/PSI/Project.asmx
    <?xml version="1.0" encoding="UTF-8"?>
    <soapenv:Envelope xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/" xmlns:proj="http://schemas.microsoft.com/office/project/server/webservices/Project/" xmlns:projds="http://schemas.microsoft.com/office/project/server/webservices/ProjectDataSet/">
    <soapenv:Header />
    <soapenv:Body>
    <proj:QueueCreateProject>
    <proj:dataset>
    <ProjectDataSet xmlns="http://schemas.microsoft.com/office/project/server/webservices/ProjectDataSet/">
    <Project>
    <PROJ_UID>e1c2d38b-1529-4128-b707-42a94045e55b</PROJ_UID>
    <PROJ_NAME>Proj Dept Test 2</PROJ_NAME>
    <PROJ_TYPE>0</PROJ_TYPE>
    </Project>
    <ProjectCustomFields>
    <CUSTOM_FIELD_UID>4802a711-62a0-4f84-8e08-c7d22daadb5b</CUSTOM_FIELD_UID>
    <PROJ_UID>e1c2d38b-1529-4128-b707-42a94045e55b</PROJ_UID>
    <MD_PROP_UID>9d77d62a-a92e-4d40-adc8-446c90eb7456</MD_PROP_UID>
    <FIELD_TYPE_ENUM>21</FIELD_TYPE_ENUM>
    <CODE_VALUE>a47930d6-b89d-4f3a-b4e3-522015fe82a1</CODE_VALUE>
    </ProjectCustomFields>
    </ProjectDataSet>
    </proj:dataset>
    <proj:validateOnly>true</proj:validateOnly>
    </proj:QueueCreateProject>
    </soapenv:Body>
    </soapenv:Envelope>
    Response
    <s:Envelope xmlns:s="http://schemas.xmlsoap.org/soap/envelope/">
    <s:Body>
    <s:Fault>
    <faultcode>s:Server</faultcode>
    <faultstring xml:lang="en-US">ProjectServerError(s) LastError=GeneralUnhandledException Instructions: Pass this into PSClientError constructor to access all error information</faultstring>
    <detail>
    <errinfo>
    <general>
    <class name="General Unhandled Exception in _Project.QueueCreateProject_">
    <error id="42" name="GeneralUnhandledException" uid="184feeaf-906a-e411-9b2a-00155d388b02" Exception="System.Data.StrongTypingException: The value for column 'PROJ_TYPE' in table 'Project' is DBNull. ---> System.InvalidCastException: Specified cast is not valid.
    at Microsoft.Office.Project.Server.Schema.ProjectDataSet.ProjectRow.get_PROJ_TYPE()
    --- End of inner exception stack trace ---
    at Microsoft.Office.Project.Server.Schema.ProjectDataSet.ProjectRow.get_PROJ_TYPE()
    at Microsoft.Office.Project.Server.BusinessLayer.Project.FixupProjectType(ProjectDataSet projDS)
    at Microsoft.Office.Project.Server.BusinessLayer.Project.QueueCreateProject(Guid jobUid, ProjectDataSet dataset, Boolean validateOnly)
    at Microsoft.Office.Project.Server.Wcf.Implementation.ProjectImpl.&lt;>c__DisplayClasse.&lt;QueueCreateProject>b__d()
    at Microsoft.Office.Project.Server.Wcf.Implementation.WcfMethodInvocation.InvokeBusinessObjectMethod(String businessObjectName, String methodName, IEnumerable`1 actions)"/>
    </class>
    </general>
    </errinfo>
    </detail>
    </s:Fault>
    </s:Body>
    </s:Envelope>

    Julie,
    You can create the fields that are project specifc & you can create fields that apply to all projects but have specific options for projects. Your goal is to create fields that are specific to each project, but right now you get all fields from you old project - is this correct?
    From your description below it appears that the fields in your original project are marked as applied to all projects & hence when you create a new project they are inherited. If you mark those fields as applied to certain project & then create a new project those fields will not be inherited.
    But you are right in the sense that it is limiting that there is no multi-select for "applies to" field.

  • HOWTO: Create a Boot Configuration That Has No Driver Signature Checks. Disable Driver Integrity Checks and Install a Custom Non-Signed Driver

    Hello,
    Recently, I had a task where I needed to install a custom non-signed driver onto my Windows 8 64-bit setup. As it is known, Windows has driver enforcement policies that, as a security measure, do not allow you to install non-signed drivers.
    I did not want to alter my current boot configuration so I decided to create a separate boot entry that would have driver signing policies disabled. For some reason I did not find any good source that would contain a step-by-step instruction on completing
    this task, so I decided that I'd better share my experience here.
    Lastly, there are multiple ways how you could turn off driver enforcement policies, but I find the way to do this via boot manager.
    Here's how you can do that.
    1. Press WindowsKey and type 'cmd' (without quotes) to find Command prompt, then click Command prompt icon. If you have User Account Control turned on, hold Ctrl+Shift keys pressed when clicking the icon.
    This will force Windows to ask you for elevation of command prompt. Elevation is necessary for editing Boot Configuration Database (BCD), the database used by Windows boot manager to store boot settings.
    2. In the User Account Control window click Yes to confirm elevation of command shell.
    3. At the command prompt type
    bcdedit
    to list your BCD entries.
    This will give you an output like:
    Windows Boot Manager
    identifier {bootmgr}
    device partition=\Device\HarddiskVolume2
    path \EFI\Microsoft\Boot\bootmgfw.efi
    description Windows Boot Manager
    locale en-US
    inherit {globalsettings}
    integrityservices Enable
    default {current}
    resumeobject {a329b5cf-fb29-11e1-a74d-f2c962d62240}
    displayorder {a329b5d0-fb29-11e1-a74d-f2c962d62240}
    {a329b5cc-fb29-11e1-a74d-f2c962d62240}
    {a329b5ca-fb29-11e1-a74d-f2c962d62240}
    {a329b5c2-fb29-11e1-a74d-f2c962d62240}
    {current}
    {a329b5d8-fb29-11e1-a74d-f2c962d62240}
    toolsdisplayorder {memdiag}
    timeout 30
    Windows Boot Loader
    identifier {a329b5d0-fb29-11e1-a74d-f2c962d62240}
    device vhd=[D:]\win8prowmc01.vhdx
    path \Windows\system32\winload.efi
    description Windows 8
    locale en-US
    inherit {bootloadersettings}
    recoverysequence {a329b5d1-fb29-11e1-a74d-f2c962d62240}
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8prowmc01.vhdx
    systemroot \Windows
    resumeobject {a329b5cf-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    The section that starts with Windows Boot Manager lists current settings for the boot menu. Here you find what boot entry is chosen by default, this is the one what you will boot into if you do not select any boot entry in the
    boot menu.
    The following record
    default {current}
    indicates that by default my Windows boots into configuration which I use at the moment (currently booted Windows configuration).
    To find out what exactly is current configuration, look into the list of boot entries, records that contain boot loader configuration and are titled as Windows Boot Loader in the bcdedit output.
    For example, the entry shown above is one of my boot configurations. This is one of the boot entries listed on the boot manager screen when I start my PC and it looks like:
    Windows Boot Loader
    identifier {a329b5d0-fb29-11e1-a74d-f2c962d62240}
    device vhd=[D:]\win8prowmc01.vhdx
    path \Windows\system32\winload.efi
    description Windows 8
    locale en-US
    inherit {bootloadersettings}
    recoverysequence {a329b5d1-fb29-11e1-a74d-f2c962d62240}
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8prowmc01.vhdx
    systemroot \Windows
    resumeobject {a329b5cf-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    This record has a unique GUID identifier that can be used to reference this boot entry, which is:
    identifier {a329b5d0-fb29-11e1-a74d-f2c962d62240}
    If we look at the Windows Boot Manager settings, we'll see this entry is the first in order to be displayed in the boot menu on OS start (I marked the unique bits):
    displayorder {a329b5d0-fb29-11e1-a74d-f2c962d62240}
    {a329b5cc-fb29-11e1-a74d-f2c962d62240}
    It references my VHD drive, a virtual hard drive where my Windwos 8 setup is residing:
    device vhd=[D:]\win8prowmc01.vhdx
    And it also specifies that the boot manager must use UEFI BIOS extension code to access my Windows boot partition:
    path \EFI\Microsoft\Boot\bootmgfw.efi
    3. Now locate the current boot entry.
    Current boot entry contains boot settings used to boot into Windows configuration to which you are currently booted. It is referenced in the list of boot entries as a Windows Boot Loader record that has the {current} keyword inside and may
    look like:
    Windows Boot Loader
    identifier {current}
    device vhd=[D:]\win8rtm.vhdx
    path \Windows\system32\winload.efi
    description Windows 8 Enterprise RTM
    locale en-US
    inherit {bootloadersettings}
    recoverysequence {a329b5c3-fb29-11e1-a74d-f2c962d62240}
    integrityservices Enable
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8rtm.vhdx
    systemroot \Windows
    resumeobject {a329b5c1-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    hypervisorlaunchtype Auto
    Because we are more than happy with current configuration and want to base our new boot configuration on these settings, we need to copy this boot entry ({current}) to a new boot entry.
    This is done by running the following command:
    C:\Windows\system32>bcdedit /copy {current} /d "No Driver Signature Check"
    Parameter /d here indicates that the following sequence of characters specifies the display name for the new boot entry that we are creating. The name inside the double quotes will be displayed in the boot menu when you boot your Windows.
    In other words, if you know restart your system, you'll see the new No Driver Signature Check in the boot menu.
    When copied, the entry is automatically given a new GUID identifier, so upon running the command above, you'll see the following line returned (you'll have an other GUID since these are unique identifiers):
    The entry was successfully copied to {a329b5d8-fb29-11e1-a74d-f2c962d62240}.
    4. Make sure the entry has been successfully created.
    Run the same bcdedit. (You may specify /enum or /v, or both /enum /v parameters at the prompt to get more detail about boot entries, but simple bcdedit is just enough to see the new entry):
    C:\Windows\system32>bcdedit
    Windows Boot Manager
    identifier {bootmgr}
    device partition=\Device\HarddiskVolume2
    path \EFI\Microsoft\Boot\bootmgfw.efi
    description Windows Boot Manager
    locale en-US
    inherit {globalsettings}
    integrityservices Enable
    default {current}
    resumeobject {a329b5cf-fb29-11e1-a74d-f2c962d62240}
    displayorder {a329b5d0-fb29-11e1-a74d-f2c962d62240}
    {a329b5cc-fb29-11e1-a74d-f2c962d62240}
    {a329b5ca-fb29-11e1-a74d-f2c962d62240}
    {a329b5c2-fb29-11e1-a74d-f2c962d62240}
    {current}
    {a329b5d8-fb29-11e1-a74d-f2c962d62240}
    toolsdisplayorder {memdiag}
    timeout 30
    Windows Boot Loader
    identifier {current}
    device vhd=[D:]\win8rtm.vhdx
    path \Windows\system32\winload.efi
    description Windows 8 Enterprise RTM
    locale en-US
    inherit {bootloadersettings}
    recoverysequence {a329b5c3-fb29-11e1-a74d-f2c962d62240}
    integrityservices Enable
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8rtm.vhdx
    systemroot \Windows
    resumeobject {a329b5c1-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    hypervisorlaunchtype Auto
    Windows Boot Loader
    identifier {a329b5d8-fb29-11e1-a74d-f2c962d62240}
    device vhd=[D:]\win8rtm.vhdx
    path \Windows\system32\winload.efi
    description No Driver Signature Check
    locale en-US
    inherit {bootloadersettings}
    recoverysequence {a329b5c3-fb29-11e1-a74d-f2c962d62240}
    integrityservices Enable
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8rtm.vhdx
    systemroot \Windows
    resumeobject {a329b5c1-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    hypervisorlaunchtype Auto
    The entry has been created and given a unique a329b5d8-fb29-11e1-a74d-f2c962d62240 ID. It now has exactly same boot settings as the boot entry we used to boot into current configuration of Windows.
    5. Modify created  No Driver Signature Check entry and specify that Windows must have driver integrity checks disabled when booted using this boot entry.
    Any modifications to boot entries are made using /set parameter. To indicate that we modify a specific boot entry, we must specify the GUID for the No Driver Signature Check record, which is:
    identifier {a329b5d8-fb29-11e1-a74d-f2c962d62240}
    In other words, to edit (add or change) an option for the boot entry, we need to use the following command syntax:
    C:\Windows\system32>bcdedit /set GUID <boot_option> [<option_value>]
    First, we must specify that we don't want integrity checks be made. This is done by adding the loadoptions option and setting it to DISABLE_INTEGRITY_CHECKS value:
    C:\Windows\system32>bcdedit /set {a329b5d8-fb29-11e1-a74d-f2c962d62240} loadopti
    ons DISABLE_INTEGRITY_CHECKS
    The operation completed successfully.
    6. Verify that load option has been added.
    Run the bcdedit command:
    Windows Boot Loader
    identifier {current}
    device vhd=[D:]\win8rtm.vhdx
    path \Windows\system32\winload.efi
    description Windows 8 Enterprise RTM
    locale en-US
    inherit {bootloadersettings}
    recoverysequence {a329b5c3-fb29-11e1-a74d-f2c962d62240}
    integrityservices Enable
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8rtm.vhdx
    systemroot \Windows
    resumeobject {a329b5c1-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    hypervisorlaunchtype Auto
    Windows Boot Loader
    identifier {a329b5d8-fb29-11e1-a74d-f2c962d62240}
    device vhd=[D:]\win8rtm.vhdx
    path \Windows\system32\winload.efi
    description No Driver Signature Check
    locale en-US
    loadoptions DISABLE_INTEGRITY_CHECKS
    inherit {bootloadersettings}
    recoverysequence {a329b5c3-fb29-11e1-a74d-f2c962d62240}
    integrityservices Enable
    recoveryenabled Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8rtm.vhdx
    systemroot \Windows
    resumeobject {a329b5c1-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    hypervisorlaunchtype Auto
    7. Add the option that turns on test signing mode and disables checks of driver signature.
    Adding the testsigning option and setting it to ON does the trick for us:
    C:\Windows\system32>bcdedit /set {a329b5d8-fb29-11e1-a74d-f2c962d62240} TESTSIGNING ON
    8. Now we have a boot entry that enables Windows not to do integrity checks and digital signature validation.
    We check it by running bcdedit:
    Windows Boot Loader
    identifier {a329b5d8-fb29-11e1-a74d-f2c962d62240}
    device vhd=[D:]\win8rtm.vhdx
    path \Windows\system32\winload.efi
    description No Driver Signature Check
    locale en-US
    loadoptions DISABLE_INTEGRITY_CHECKS
    inherit {bootloadersettings}
    recoverysequence {a329b5c3-fb29-11e1-a74d-f2c962d62240}
    integrityservices Enable
    recoveryenabled Yes
    testsigning Yes
    isolatedcontext Yes
    allowedinmemorysettings 0x15000075
    osdevice vhd=[D:]\win8rtm.vhdx
    systemroot \Windows
    resumeobject {a329b5c1-fb29-11e1-a74d-f2c962d62240}
    nx OptIn
    bootmenupolicy Standard
    hypervisorlaunchtype Auto
    9. Type 'exit' without quotes to exit from command prompt, and restart Windows.
    Upon booting you will be present with a new boot option to start Windows in configuration that allows you to install custom non-signed drivers.
    Hope this will help anybody to create their own custom boot configurations.
    Well this is the world we live in And these are the hands we're given...

    Hi,
    Thank you for sharing the solutions & experience here. It will be very beneficial for other community members who have similar questions. 
    Regards,
    Kelvin hsu
    TechNet Community Support

  • Create Document Set with custom Create Only permission set

    Here is the situation. We have a requirement where my customer wants to create document sets, however, document set/document level permissions are required.
    Setup: We created a new permission level called "Create Only". We then give the user Read and Create only permissions. This allows the user to theoretically create the item. We then run a Workflow on create that Replaces the permissions so that
    you are only allowed to view the ones you created along with other security groups based on their choices in the metadata fields.
    This setup works PERFECTLY when using a List or Form Library.
    However, for the life of me I cannot get it to work for Document Sets. If I have the same setup, I get an Access Denied message. However, it still creates the document set.
    What is weird, I've been playing around with custom permission levels and it seems as though the user has to have EDIT permissions at a minimum in order to create the document set. This will not work for me since I dynamically assign permissions to each
    document set based on what they select.
    As a side note, the only tool I have at my disposal is SharePoint Designer 2010.
    Does anyone know if there is an actual requirement to have EDIT permissions when creating a Document Set? Any input would be greatly appreciated.
    Alternatively, is there a way to setup permissions on a library for all NT Authenticated users so that we can give them the necessary permissions to create the Document Set, but still prevent them from see the other items and then the Workflow would set
    the permissions accordingly?
    I believe the more granular the permissions it uses those permissions instead so would this work?  I have not tested this theory yet.

    Hi,
    According to your description, my understanding is that you want to know if there is an actual requirement to have EDIT permissions when creating a Document Set and is there a way to setup permissions on a library for all NT Authenticated users and prevent
    them from seeing items created by others.
    For the first question, per my knowledge, if a user is given the Add Items permission, he/she can create a document set in SharePoint.
    However, there is an error “access denied” after the document set is created. It is due to the user has no permission to access the page which SharePoint will redirect the user to after finishing creating the document set.
    If the user is also given Edit Items permission, there will be no error when he/she create a document set.
    For the second question, I recommend to follow the link below to
    customize item permissions for each document submitted to a document library and remember to give the
    NT Authenticated users contribute permission.
    http://blogs.technet.com/b/spke/archive/2010/04/09/configure-item-level-permissions-for-document-libraries-sharepoint-2010-edition.aspx
    To grant permission to NT Authenticated users, please refer to the link below:
    http://office.microsoft.com/en-in/sharepoint-server-help/what-happened-to-add-all-authenticated-users-HA101805183.aspx
    Best regards.
    Thanks
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Bug report about create new footprint with Rounded rectangle in 3D info Bottom

    I create new footprint with rounded rectangle in 3D info Bottom,the rounded rectangle must be in bottom,but In fact,the rounded rectangle
    created in top layer.i think it's wrong.
    I used ultiboard 10.1.357.

    Hi,
    Thank you for reporting this. This has been a long standing issue with Ultiboard and we are looking into resolving this.
    There is a work around although a very inconvenient one. You can set the height to what you require and use a negative offset to move the shape to the other side of the board. The 3D shape will appear on the other side, but in reality is just shifted, not mirrored.
    Hope that helps. We apologize for the inconvenience.
    Yi
    Software Developer
    National Instruments - Electronics Workbench Group

  • Creating a Customized Pad in Ultiboard

    I am trying to create a Customized Pad with a Specific size in Ultiboard so that I can make use of it for my PCB Design.  I tried to customized a Chip Pad from the Master Database in Ultiboard, but am not successful. 
    I would appreciate if anyone could give me the steps or guidelines on how I can achieve creating a Pad of specific dimensions or sizes.
    Regards.

    Hi there,
    If you want to edit an exist Chip Pad in the Master Database, you should copy it to the User Database first.( right click the item, and then select User Database)
    The following tutorial might be helpful to create a custom component in Ultiboard.
    Creating a Custom Component in NI Ultiboard
    http://www.ni.com/white-paper/5631/en/
    Hope this helps!:-)
    Regards,
    Chen_T
    National Instruments

Maybe you are looking for