Creation of Custom Infotypes

Hi Guy's,
Please help me How to create the Custom Info types in Campus management(Step-by-Step) procedure.
Thanks,
Bhavani.
Edited by: Michael Fan  on Mar 13, 2008 2:33 PM - I changed to title to something more meaningful.

Hi ,
For OM infotypes it is PPCI and PD infotypes  it will be PM01.
Just find this in the ERP HCM where you can find the links .
Refer this link :
http://help.sap.com/erp2005_ehp_03/helpdata/EN/1e/728d281d5e11d289d30000e82158f1/frameset.htm
Regards
Gajalakshmi

Similar Messages

  • Creation of custom infotype

    Hi all,
    I have a requirement wherein i need to create a infotype.
    In this infotype if the Anzhl value of absence quota type  is reduced the relavent quota types which are linked to it should also get reduced.
    Actually when a leave is approved, the quota is reduced and reflected in 2006 only but here in my case it should get reflected in the new infotype also by creating a seperate record with the entitlement and reduced values.
    for ex awart1
    suppose for 20 days is reduced from awart1. Awart2 and awart3 are linked to awart1.
    simultaneously 20 days quota needs to be reduced from awart2 quota, as well as some 5 days from awart3.
    so there will be two records of this new infotype
    and also, the ANZHL of the relevant quotas will be reduced
    when the leave gets cancelled, these two records will be deleted and quota will be reinstated back
    Please help me by providing pointers in this regard.
    Thanks in advance.
    Regards,
    Durga.

    Hi
    use the  t-code  PM01  to create new custom infotype..i wiht in 9000-9999 number range..
    Have a search on SDN  for the same..............therea re lots of  thered for the same...
    ..lakhan

  • Creation of Custom Infotype in Recruitment

    Hi Experts,
    I have actually used PM01 to created Custom infotype. i have selected the applicant group while creating the infotype.. but in the infotype charectaristics the database table is still PA9006 this must be changed to PB.. how do i do this???? And my 9006 infotype in not reflecting in the applicant master data.. how to do this?????

    hi,
    i think you select pa infotype while providing time constraint, insted of selecting pa infotype select RE infotype or
    follow this procedure......
    1)in step one you create STRCTURE with required fields and make it activate
    2) in this step simply click on CREATEALL BUTTON for creating module pool program, database table and screens.
    3) in this step select NEW ENTRIES button and here provide information like ...
    if you are not find new entries button click on EDIT button.
    a)provide Infotype number ( which is created by you. 9006)
    b)provide description
    c) provide time constraint
    d)provide single screen(2000)  and list screen(3000)
    now click on  SAVE button then system automatically assigns the application database table PB9006.
    regards,
    Ashok
    Edited by: Ashok Reddy on Jul 1, 2008 5:45 PM

  • Creation of Customized Infotype

    Hi,
    I have created an infotype, for which i have designed screens in SE80.  But still When I execute the infotype in PA30 Transaction, I am getting an error saying that
    Screen MP902400 2000 must not be an Include screen.
    I am new to this HR module. Please give me a solution to solve this problem.
    Thank You.
    DhanaLakshmi M S

    The screen type was selected as Subscreen instead of Normal screen.
    Thank You.
    DhanaLakshmi MS

  • Error executing Custom Infotype..

    An Invalid table name PA9001 is mentioned in the open SQL Statement.
    Runtime Error:SAPSQL_INVALID_TABLENAME
    Exception:CX_SY_DYNAMIC_OSQL_SEMANTICS occoured in procedure READ_DATABASE but neither
    handled locally nor declared in the RAISING clause of its signature.
    Termination occoured in ABAP Program SAPFP50P- in "READ_DATABASE".
    The main Program was "MP900100".
    I did not do any modifications in the programming part.Even then I am getting the errors..

    I had faced these issues before while creation of custom infotype. But I found later that its the incorrect authorizations which is not allowing the system to create the structures.
    When you create an infotype, sap follows few steps to create various strcutures and table enties.
    But due to insufficient authorizations, many of them are skipped. e.g. A functional person does not have authorization to create tables/ structures through SE11. I think this is the reason why the table PA9xxx is not created in your case.
    Fix your authorizations, and recreate the custom infortype.
    Reward points if it helps.

  • Significance of classes in custom infotypes???

    hello everyone,
    i know that on creation of custom infotype a class will be created. i want to know the significance of the classes. if i change the name of the class will it effect any thing?? if i change the name of the class where all places should i change the name etc......??
    and question2.
    On creation of infotypes SAP generates standard code. in that i found that in PAI two sets of chain-endchain statements are there with the same fields. what will be the effect if i remove one set..
    pls respond at the earliest .
    Thanks,
    shiva.

    http://www.hr-manager.de/cgi-bin/yabb2/YaBB.pl?num=1045064431
    check this link it may help u
    regards
    anil chaudhary

  • Custom infotype creation issue

    Hi Experts,
    I have a requirement to create a custom infotype based on certain conditions. But there is a problem while saving data in the infotype. The infotype is populated from another infotype automatically through dynamic actions.
    But while saving the data for the first time it happens as per the requirements and data gets saved properly.
    But when the data is saved for the second time for the same pernr , the previous data is over written even though the new record starts with a different begin data.Also i have created the infotype with time constraint '1'.
    can you please let me know if i am missing anything while creating or is this a logic issue .? all the logic has been coded in the flow logic part of the screen.
    also if i dont save the data in the infotype it does not pop up any message like 'data not saved' which usually happens with every infotype. Please clarify me on this as well...
    Thanks,
    Raj Thilak.

    Hi,
    Check the logic how it is updating the custom infotype . I think it is nothing to do with creation of custom info type
    Regards
    Krishna

  • Error in creation of custom PD infotype

    Hi,
    I have a task of creating a custom PD infotype(p9xxx). I created HRI9xxx structure with all the custom fields and when I try to create the infotype using tcode PPCI(selected 'field infotype' option and create button in the 'infotype' block was pressed), it gives an error message that p9xxx-begda is not in ABAP dictionary and then it gives me list of screens, module pools and tables created. This custom infotype entry does not exist in T777I. I have tried regenerating it and same problem persists. If anyone knows the solution, please do let me know.
    Thanks in advance

    Solved.

  • Problem in creating help input for custom infotype creation

    Hi,
    I had the task of creating a custom infotype for storing recruitment test result.
    I created it using the following structure:
    Component ______________Data Element
    TEST_TYPE______________ZTEST_TYPE
    TEST_DATE
    LOCATION
    PIC_____________________RFPER
    EX_PIC
    TEST_RESULT____________ZRESULT_TYPE
    STATUS_________________ZSTATUS_TYPE
    OTHER_POSITION_________PLANS
    Now for the component other_position for the entry help i use is H_T528B with check table T528B. My objective is, when the infotype is accessed through pa30 and user is inputting the entry, when they press F4 on the inputbox for other_position, help search should show the list of all position within the system. But rather than that, the input help display such message:
    No values selected
    Maintain entries?
    Yes       No         Cancel
    When I choose yes, the input help suddenly prompt me to "Choose customizing project"  which i believe is from SPRO.
    How do I fix this problem so that when I press f4, the help will shows all position within the system.
    Thanks

    not answered, but found another work around

  • Custom fields on OM to trigger creation of 0001 infotype record

    Hi Everyone,
    I need to resolve this as soon as possible.
    I have a requirement as follows:-
    There is a Custom infotype with 2 fields on a custom tab on Position level in OM.
    Now, when there is any change to the field contents and the validity dates, the integration should be triggered alongwith creating a corresponding entry in 0001 infotype in the background, just like it happens for all the other tabs/infotypes in OM.
    I already found a BADI, HRBAS00INFTY which enables me to change the code before updation of the database.
    Please let me know how to create the Info type 0001 records once the custom fields and validity dates are changed.
    Thanks and Regards,
    Pankaj.

    Hi Pankaj,
    Use the FM HR_INFOTYPE_OPERATION to update 0001.
    Regards
    Bala

  • Custom Infotype Creation in ORG Management

    Vijay,
    Can you send me the steps so I can assign the points.
    Thanks,
    Parina

    Here are the steps that I followed:
    Enter the transaction code PPCI
    Enter a four digit infotype number (9nnn) and an infotype name.
    Select Field Infotype
    Choose Infotype Create.
    Choose Check environment to maintain the required entry in table T777I (Infotypes per object type).
    Choose the Entry 'T777I' under the list of 'Table Entries' (This list is produced when you choose 'Check' on the First screen of the Transaction PPCI.
    Press the 'Change' button and you will be taken to the 'Maintain Table Views' Transaction (SM30).
    Press the Maintain button.
    From the list of Infotypes locate the custom infotype created and select the entry for that.
    Click on the 'Time Constraint' folder appearing on the left hand corner of the screen.
    The screen for Change View Time Constraint would appear.
    In the object type field put in: O,P,S whatever is relevant to your requirement.Also add the time constraint.
    Save it and double click on the 'Infotypes per object type' folder (on the left hand side again).
    Create a new entry here for your infotype and save it.
    Come back to the Transaction PPCI and you are all set.
    This is all I did and it worked.
    Thanks,
    Vijay

  • Error in custom infotype creation

    Hi
    I have created a custom infotype IT9100 .
    When I am seeing the screen layout in se51 information message
    Element PSPAR-ITTXT touches or overlaps other element
    ITTXT stores the infotype text
    Now when I am activating my screen its showing error
    Collision at target location.*
    Could you please let me know how to deal with such prob.
    P

    Hi,
    please check whether in the layout set may be those fields are overlaping.
    generally i didnt get those type of messages.

  • Problem while creation custom Infotype for HRP (Organization mgmt)

    Hiii...
    Newbie to HR-ABAP...
    I have successfully created a custom infotype for HRP (Organization mgmt)....how can i see the infotype in t-code PP01.
    Thanks
    A

    Hi
    Perhaps MM11/12 can't update your custom field because you have use a data element where the flag Document change isn't setted.
    Max

  • Problem in Tabstrip Control in Custom Infotype Creation

    Hi All,
    Can any body tell me how to process with Tabstrip Control in an Custom Infotype.
    Iam creating Customizing Infotype With Tabstip Control.The Tabstrip Control have 2tabs.Each tab have Custom some fields.
    But iam not able activating the sample Tabstrip control.
    Can u tell me how to approach to create this in Modulepool programming for my Custom Infotype.
    Points wil be rewarded.
    Thanks,
    N.L.Narayana

    Hello Swapna,
    Thanks for your reply.
    This is my code for tabstrip control.
    AT SELECTION-SCREEN.
    CASE SSCRFIELDS-UCOMM.
       WHEN 'BOOK'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 1.
         tabb1-activetab = 'TABS1'.
         option = '1'.
       WHEN 'SUMM'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 2.
         tabb1-activetab = 'TABS2'.
         option = '2'.
       WHEN 'POST'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 3.
         tabb1-activetab = 'TABS3'.
         option ='3'.
    *CH01 start
       WHEN 'RSET'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 4.
         tabb1-activetab = 'TABS4'.
         option = '4'.
    ENDCASE.
    case option.
      when '1'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
       if p1_werks is initial or p1_lgort is initial or
          p1_bstar is initial or p1_gjahr is initial.
         message e000(vz) with text-001.
       endif.
    ENDIF.
      when '2'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
       if p2_gjahr is initial.
         message e000(vz) with text-005.
       endif.
    ENDIF.
      when '3'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
       if p3_gjahr is initial.
         message e000(vz) with text-005.
       endif.
        ENDIF.
    *CH01 start
      when '4'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
      if s4_werks is initial or p4_gjahr is initial.
         message e000(vz) with text-001.
      endif.
      if p4_book is initial and
         p4_summ is initial.
         message e000(vz) with text-022.
      endif.
       ENDIF.
    endcase.
    I can give you some more information.
    If I execute from program it is working fine, if I execute from T.code it is not working properly.
    Regards.
    Krishna.

  • Custom infotyp creation error

    Hi,
    I am creating a customized infotype, when i activate the layout shows me the error message "Input/output field not defiend"
    But am unable to input the check in screen painter already the field is disabled.  Pls Assist. URGENT.

    Hi,
    For this you need to go to the change mode on the screen painter and then click on input/output field..
    Or you can go directly yo the element list of your screen and check the I/O option there for that field.
    Regards
    Sonu Gupta

Maybe you are looking for

  • Server side eventing

    Hi developers, I got the following problem in a customer's project. Analoguous to the tutorial in the sdn about server side eventing (In the component interface controller the event InnerEvent is fired and passes the stringparameter text to the event

  • Re PowerShot SX510HS: is there a proper protocol for disconnecting the camera from the USB cable?

    With my previous camera (not Canon) instructions said I must "safely" disconnect the camera from the USB cable inserted into the back of my computer.  What is the safe way to disconnect my new Canon...can I just pull the cord out?   Cheryl

  • Taking Dump of Ports, Partner Profiles etc before Client Deletion

    Hi, Let me firstly tell you about the requirement. I need to delete a 9TB client using TDMS. And then re-create it again for users. Now the problem is , that the Partner Profiles, Ports will be deleted when I delete the client, which I cannot afford

  • Hub 4 keeps loosing broadband connectio

    I have been in touch with cust service several times. my hub 4 (a replacement two weeks ago when the problem was first thought to be the hub) keeps disconnecting from the internet. it can be fine for days, then at other times it can disconnect every

  • Probléme pour enregistrer dans une version antérieure (vi.lib)

    bonjour  je suis étudiant, je travaille avec la version 2009 de Labview ( fourni par mon école) et j'aimerais convertir mon application en Labview 8.2. Malheureusement lorsque je fais enregistrer dans une version antérieure j'ai le message suivant :