Creation of generic extractor in CRM
Hi Experts,
I want to create generic extractor in CRM.
In R/3 we can use table like VBAK,VBAP..etc while creating Generic extracor.But I am not able to find tables for transactions like Activities,Opportunities ...etc in CRM.
Pls let me know how to find tables in CRM.
Regards
Vishal.
Hi Vishal,
The orders tables in CRM are CRMD_ORDERADM_H (header) and CRMD_ORDERADM_I (item-level).
For other tables, usually they begin with CRMD_*. They're related to document informations, like for example: CRMD_PARTNER for partners, CRMD_ORGMAN for document organizational data, and so on....
Kind regards,
Similar Messages
-
How to Generate Information Errors in Generic Extractor Function Module
Hi, In my Generic Extractor logic I am reaching out to an additional table to get a field. I would like to produce an informational error or red error in the process monitor if I'm unable to get the field. Is this possible? How can I generate these messages in the Extractor Function Module?
Thanks!Hi,
Please go through the below doc. It explanins each and every step of creation of generic extractor through Function module.
http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/a0f46157-e1c4-2910-27aa-e3f4a9c8df33?quicklink=index&overridelayout=true
http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/c062a3a8-f44c-2c10-ccb8-9b88fbdcb008?quicklink=index&overridelayout=true
http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/30aefb04-7043-2c10-8e92-941536eebc79?quicklink=index&overridelayout=true
Regards,
mahesh -
Creation of a generic extractor and data source for the FAGLFLEXA table
Hi All,
Need to create a generic extractor and data source for the FAGLFLEXA table to support AR reporting. This table contains the necessary profit center information to perform LOB reporting against the AR data.
Please advice on how to do this.
Regards, VishalHi Vishal,
Its seems a simple a work out.
1.Go to RSO2 & choose the relevant option ie. whether you want to create Transactional DS, Master Data DS or Text DS.
2. Name it accordingly & then create.
3. Give description to it & then give table name FAGLFLEXA.
4. Save it & activate. If you need it to be delta enabled then click over Delta & you can choose accordingly.
If you still face some problem then do mail me at [email protected]
Assign points if helpful
Regards,
Himanshu -
How to use 2 date field as delta control in generic extractor.
Hi colleagues:
I have developed a generic extractor to extract logistic data: Purchase Orders and Invoice. In order to do that, I have defined a view joining EKBE, EKKO, EKPO, EKET tables on R/3. By this approach, the delta mechanism is supposed to be controlled by the EKBE-BUDAT field and also by the EKPO-AEDAT field. Both fields are available on the view used to create the Datasource. However, the Datasource creation allows us to define just one field as delta control.
I have a few questions regarding to this scenario:
<b>1 - Is it possible to define 2 fields as delta control field on Generic Datasource?</b>
<b>2 - How about creating two similar Datasouces, one having AEDAT as delta control, the other having BUDAT as delta control, and then connect those Datasources to an unique Infosource on the bw side?</b>
Best regards
Waldemarhi,
1 - as far as I know it is not possible to define 2 fields
2 - this workaround is used often in cases like yours.
Just remember about order of extracting: first you extract new documents then changed
Regards,
Andrzej -
Generic extractor question/problem
Hello,
I want to create a generic extractor on custom table which should delta enabled . This custom table has ERDAT( creation date) and ERZET u2013 Entry time but the client is asking me to use both fields for delta functionality . I am not sure how to do this . Please help .
Regards,As you said client want you to use both the date n time stamp field to extract delta you can follow the below steps.
- Create the generic data source as per you requirement in order to pic the delta
- Open you extract structre and append the field TZNTSTMP, this is the field which holds the time stamp.
- to setup deltas click on generic delta --> select time stamp(UTC)
Regards
KP -
"Appl specific BW content Extractors" vs "Appl specific Generic Extractors"
whats is the difference between "Appl. specific BC Extractors" and "Appl. specific Generic. Extractors".
Could someone elaborate from technical, implementation and business scenario perspectives.
Thanks
nullHi ,
<b>Application Specific Extractors :</b>
This is further classified into
1. Business Content Extractors
2. Customer Generated Extractors .
<b>Business Content Extractors :</b>
The applications that uses this are :
Logistics ( LO ), Finace ( FI ) , HR , CRM ..
SAP provided the predefined data sources , Extractors , Info cubes in Business content data sources . The thing that you have to do is , Instal business Content , <b><i>Activate the SAP Defined data souce</i></b> , Extract the data and send to BI .
<b>Customer Generated Extractors :</b>
For some application which vary from company to company like LIS , CO-PA ,
FI-SL because of its dependence on organization structure , SAP was not able to provide a standard data source for these application , <i><b>So customer have to generate their own data source</b></i>. But SAP provides other objects like Info Cubes for these . So this is called Customer gnerated Extractors .
<b>Generic Extractors :</b>
When the requirment of your company could not be acheived by SAP delivered businedd content data source , Then you have to create your own data source that is purely based on your compnays requirment , That is called generic extractors .
Based on the complexity you can create Data source in 3 ways .
1. Based on Views ( Simple Apllications )
2. Based on Info set Query
3. Based on Function Module ( Used in complex extraction ).
Here you have to Create Data source , Info Cube , Etc ...Every thing as new one .
Best Regards
Renjith Kumar -
Hi SDN,
Im trying to create Generic Data source of View Method. I wanted to create View on BSID ( Closed Customer Invoices) and BSAD ( Open Customer invoices) Tables, But while creating its giving error as "THERE IS NO RELATION BETWEEN THE TABLES" I want to know how to create Relation Between the tables. Both BSID & BSAD are standard tables, so we cant make any changes.
Please let me know the procedure to bulid Rlation between the tables.
Regards
SujanHi Siva,
You have to give relation between these two tables in tab "Table/Join Conditions".
Creating Views:
http://help.sap.com/saphelp_webas620/helpdata/en/cf/21ecf9446011d189700000e8322d00/frameset.htm
View creation fr generic extraction
Hope it Helps -
Need steps in creation of LO extractor
Hi All,
I am new to SAP BI, I am working on **LO and FI-Sl extractor..can any of you please provide me the detail steps in creation of these extractors.
Please do the needful by providing the required information.
thanks,
Vinay.Hi Vinay ,
Plz find the steps below for LO
LO :
1. Run T-Code LBWE
2. Select your area EX : You want to activate the DS : 2LIS_02_SCL.Then u need to Expand the Purchaisdng application component.
3. Clcik on maange extractor
- Using this you are going to select the Required fields in u r struture by dragging from right to left
4. Click on the DS : 2LIS_02_SCL
-Here you will set the options like slection,hide etc...
5. Activate
6. Job Control..
7. Update mode .
- Used queued delta option.
8 Your LO DS is available in RSA6 T-Code.
9 You need to fill the data for the DS by running the T-Code "OLI2BIW".
10.Check the dara for the DS in RSA3.
Regardds
Ram -
Delta fo Generic extractor using function module
Hi,
I am using the following function module for generic extractor but its always showing me extraction error.Could anyone please suggest to resolve the issue.
Thanks in advance fo rsuggestion.
FUNCTION Z_BW_SALESDATA_EXTRACT_CHNG2.
""Local interface:
*" IMPORTING
*" VALUE(I_REQUNR) TYPE SBIWA_S_INTERFACE-REQUNR
*" VALUE(I_ISOURCE) TYPE SBIWA_S_INTERFACE-ISOURCE OPTIONAL
*" VALUE(I_MAXSIZE) TYPE SBIWA_S_INTERFACE-MAXSIZE OPTIONAL
*" VALUE(I_INITFLAG) TYPE SBIWA_S_INTERFACE-INITFLAG OPTIONAL
*" VALUE(I_UPDMODE) TYPE SBIWA_S_INTERFACE-UPDMODE OPTIONAL
*" VALUE(I_DATAPAKID) TYPE SBIWA_S_INTERFACE-DATAPAKID OPTIONAL
*" VALUE(I_PRIVATE_MODE) OPTIONAL
*" VALUE(I_CALLMODE) LIKE ROARCHD200-CALLMODE OPTIONAL
*" VALUE(I_REMOTE_CALL) TYPE SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
*" TABLES
*" I_T_SELECT TYPE SBIWA_T_SELECT OPTIONAL
*" I_T_FIELDS TYPE SBIWA_T_FIELDS OPTIONAL
*" E_T_DATA OPTIONAL
*" E_T_SOURCE_STRUCTURE_NAME OPTIONAL
*" EXCEPTIONS
*" NO_MORE_DATA
*" ERROR_PASSED_TO_MESS_HANDLER
The input parameter I_DATAPAKID is not supported yet !
Example: InfoSource containing TADIR objects
TABLES: VBFA,VBRK,tadir.
Auxiliary Selection criteria structure
DATA: l_s_select TYPE sbiwa_s_select.
Maximum number of lines for DB table
STATICS: l_maxsize TYPE sbiwa_s_interface-maxsize.
user defined variables.
DATA : X_UPDMODE(1) Type c, " Update Type
X_LastUpdate Like Sy-Datum. " Last Update Date
X_LastUpdate TYPE RODELTAID. " Last Update Date "TCS_KAP
Select ranges
RANGES: L_R_VBELN FOR VBAK-VBELN,
L_R_AUDAT FOR VBAK-AUDAT.
Parameter I_PRIVATE_MODE:
Some applications might want to use this function module for other
purposes as well (e.g. data supply for OLTP reporting tools). If the
processing logic has to be different in this case, use the optional
parameter I_PRIVATE_MODE (not supplied by BIW !) to distinguish
between BIW calls (I_PRIVATE_MODE = SPACE) and other calls
(I_PRIVATE_MODE = X).
If the message handling has to be different as well, define Your own
messaging macro which interprets parameter I_PRIVATE_MODE. When
called by BIW, it should use the LOG_WRITE macro, otherwise do what
You want.
Initialization mode (first call by SAPI) or data transfer mode
(following calls) ?
IF i_initflag = sbiwa_c_flag_on.
Initialization: check input parameters
buffer input parameters
prepare data selection
The input parameter I_DATAPAKID is not supported yet !
Invalid second initialization call -> error exit
IF NOT g_flag_interface_initialized IS INITIAL.
IF 1 = 2. MESSAGE e008(r3). ENDIF.
log_write 'E' "message type
'R3' "message class
'008' "message number
' ' "message variable 1
' '. "message variable 2
RAISE error_passed_to_mess_handler.
ENDIF.
Check InfoSource validity
CASE i_isource.
WHEN 'Z_BW_SDDATA_CREATEON'.
WHEN 'Y'.
WHEN 'Z'.
WHEN OTHERS.
IF 1 = 2. MESSAGE e009(r3). ENDIF.
log_write 'E' "message type
'R3' "message class
'009' "message number
i_isource "message variable 1
' '. "message variable 2
RAISE error_passed_to_mess_handler.
ENDCASE.
Check for supported update mode
CASE i_updmode.
WHEN 'F'.
WHEN OTHERS.
IF 1 = 2. MESSAGE e011(r3). ENDIF.
log_write 'E' "message type
'R3' "message class
'011' "message number
i_updmode "message variable 1
' '. "message variable 2
RAISE error_passed_to_mess_handler.
ENDCASE.
Check for obligatory selection criteria
READ TABLE i_t_select INTO l_s_select WITH KEY fieldnm = 'VBELN'.
IF sy-subrc <> 0.
IF 1 = 2. MESSAGE e010(r3). ENDIF.
log_write 'E' "message type
'R3' "message class
'010' "message number
'PGMID' "message variable 1
' '. "message variable 2
RAISE error_passed_to_mess_handler.
ENDIF.
APPEND LINES OF i_t_select TO g_t_select.
Fill parameter buffer for data extraction calls
g_s_interface-requnr = i_requnr.
g_s_interface-isource = i_isource.
g_s_interface-maxsize = i_maxsize.
g_s_interface-initflag = i_initflag.
g_s_interface-updmode = i_updmode.
g_s_interface-datapakid = i_datapakid.
g_flag_interface_initialized = sbiwa_c_flag_on.
Store Update mode in static variable...
X_UPDMODE = I_UPDMODE.
Select Single DELTAID
Into X_LastUpdate
From ROOSGENDLM
Where OLTPSOURCE = 'Z_BW_SDDATA_CREATEON'.
If X_LastUpdate Is Initial.
X_LastUpdate = '19800101'. " The oldest..., this should not happen
Endif.
Fill field list table for an optimized select statement
(in case that there is no 1:1 relation between InfoSource fields
and database table fields this may be far from beeing trivial)
APPEND LINES OF i_t_fields TO g_t_segfields.
ELSE. "Initialization mode or data extraction ?
Data transfer: First Call OPEN CURSOR + FETCH
Following Calls FETCH only
X_UPDMODE = I_UPDMODE.
First data package -> OPEN CURSOR
IF g_counter_datapakid = 0.
Fill range tables for fixed InfoSources. In the case of generated
InfoSources, the usage of a dynamical SELECT statement might be
more reasonable. BIW will only pass down simple selection criteria
of the type SIGN = 'I' and OPTION = 'EQ' or OPTION = 'BT'.
LOOP AT g_t_select INTO l_s_select WHERE fieldnm = 'VBELN'.
MOVE-CORRESPONDING l_s_select TO L_R_VBELN.
APPEND L_R_VBELN.
ENDLOOP.
LOOP AT g_t_select INTO l_s_select WHERE fieldnm = 'AUDAT'.
MOVE-CORRESPONDING l_s_select TO L_R_AUDAT.
APPEND L_R_AUDAT.
ENDLOOP.
Determine number of database records to be read per FETCH statement
from input parameter I_MAXSIZE. If there is a one to one relation
between InfoSource table lines and database entries, this is trivial.
In other cases, it may be impossible and some estimated value has to
be determined.
*added by Yogesh
DELETE FROM ZBWSALEDATA.
*ended by Yogesh
l_maxsize = g_s_interface-maxsize.
Check for supported update mode
CASE X_UPDMODE.
WHEN 'F' Or 'I'. " Full or Init
**get sales orders
SELECT *
INTO CORRESPONDING FIELDS OF TABLE I_SALESDATA
FROM VBAK AS K
INNER JOIN VBAP AS P
ON PVBELN = KVBELN
WHERE K~VBELN IN L_R_VBELN
AND K~AUDAT IN L_R_AUDAT
AND K~VBTYP = 'C'.
IF I_SALESDATA[] IS NOT INITIAL.
PERFORM F_GET_DATA. "get data
PERFORM F_DEL_VATCOND. "delete vat conditions
PERFORM F_GET_TAR_COSTUNIT. "get tariff cost unit
PERFORM F_GET_NETVAL TABLES IT_VBDPA1. "get net val of the item
PERFORM F_GET_SALESDATA.
*write perform with name F_INSERT_DB_ZBWSALEDATA.
PERFORM F_INSERT_DB_ZBWSALEDATA. "insert into table ZBWSALESDATA
LOOP AT I_SALESDATA WHERE NETPR = 0.
MOVE-CORRESPONDING I_SALESDATA TO I_SALESDATA_FIN.
APPEND I_SALESDATA_FIN.
ENDLOOP.
SORT I_SALESDATA_FIN BY VBELN POSNR KSCHL.
DELETE ADJACENT DUPLICATES FROM I_SALESDATA_FIN
COMPARING VBELN POSNR
KSCHL.
INSERT ZBWSALEDATA FROM TABLE I_SALESDATA_FIN.
ENDIF.
WHEN 'D'. " Delta
SELECT *
INTO CORRESPONDING FIELDS OF TABLE I_SALESDATA
FROM VBAK AS K
INNER JOIN VBAP AS P
ON PVBELN = KVBELN
WHERE K~ERDAT >= X_LastUpdate
WHERE K~ERDAT >= X_LastUpdate+0(8) "TCS_KAP
AND K~VBTYP = 'C'.
IF I_SALESDATA[] IS NOT INITIAL.
PERFORM F_GET_DATA. "get data
PERFORM F_DEL_VATCOND. "delete vat conditions
PERFORM F_GET_TAR_COSTUNIT. "get tariff cost unit
PERFORM F_GET_NETVAL TABLES IT_VBDPA1. "get net val of the item
PERFORM F_GET_SALESDATA.
*write perform with name F_INSERT_DB_ZBWSALEDATA.
PERFORM F_INSERT_DB_ZBWSALEDATA. "insert into table ZBWSALESDATA
LOOP AT I_SALESDATA WHERE NETPR = 0.
MOVE-CORRESPONDING I_SALESDATA TO I_SALESDATA_FIN.
APPEND I_SALESDATA_FIN.
ENDLOOP.
SORT I_SALESDATA_FIN BY VBELN POSNR KSCHL.
DELETE ADJACENT DUPLICATES FROM I_SALESDATA_FIN
COMPARING VBELN POSNR
KSCHL.
INSERT ZBWSALEDATA FROM TABLE I_SALESDATA_FIN.
ENDIF.
WHEN OTHERS.
IF 1 = 2. MESSAGE E011(R3). ENDIF.
LOG_WRITE 'E' "message type
'R3' "message class
'011' "message number
I_UPDMODE "message variable 1
' '. "message variable 2
RAISE ERROR_PASSED_TO_MESS_HANDLER.
ENDCASE.
**end get sales orders
OPEN CURSOR WITH HOLD g_cursor FOR
SELECT (g_t_fields) FROM ZBWSALEDATA.
WHERE pgmid IN l_r_pgmid AND
object IN l_r_object.
ENDIF. "First data package ?
Fetch records into interface table. There are two different options:
- fixed interface table structure for fixed InfoSources have to be
named E_T_'Name of assigned source structure in table ROIS'.
- for generating applications like LIS and CO-PA, the generic table
E_T_DATA has to be used.
Only one of these interface types should be implemented in one API !
FETCH NEXT CURSOR g_cursor
APPENDING CORRESPONDING FIELDS
OF TABLE E_T_DATA
PACKAGE SIZE l_maxsize.
IF sy-subrc <> 0.
CLOSE CURSOR g_cursor.
RAISE no_more_data.
ENDIF.
g_counter_datapakid = g_counter_datapakid + 1.
ENDIF. "Initialization mode or data extraction ?
Best regards,
YogeshDear Yogesh,
Try to debug the code by putting a break point at select statement...is the FM Syntactically correct ??
Check the Select statements..if all fields are not required avoid using Select * , and use always for all entries rather than JOINS..
Note : For Joins you have to specify the Fields in the Select...Dont use Select * ....
Hope it helps..
Thanks,
Krish -
Problem in creating a Generic Extractor on a custom 'Z' table
This is regarding an earlier question I posted in sdn today. I am trying to create a generic extractor on a custom 'Z' table and iam getting the following message.
Invalid extract structure template YBW_Z3PVR of DataSource YCNA_3PVAR_RPT
Message no. R8359
Diagnosis
You tried to generate an extract structure with the template structure Z3PVR. This operation failed, because the template structure quantity fields or currency fields, for example, field MENGE refer to a different table.
Procedure
Use the template structure to create a view or DDIC structure that does not contain the inadmissable fields.
Please advise. how do i solve this?Hi there,
Is your Z* table working? It must be add check field for quantity field and currency field.
Hope this helps. -
Error while creating Generic Extractor via Function Module
Hello Guys
I have created a Generic Extractor through a Function Module. I took the Standard FM: RSAX_BIW_GET_DATA_SIMPLE, gave it a new name and activated it. I made a few changes in it, like giving my structure name for E_T_DATA and giving the list of tables, from where I need to get the data. Then I created the datasource in RSO2 by giving this function module and the extract structure.
The DS was created properly, but when I check in RSA3 for records, its giving me an error: ---> <b>The extraction program does not support object YCNA_INVY_TRNS</b>
What do i do now? Can someone please tell me, what changes I need to make in the standard FM to suit my requirements??
Thanks.Hi,
Just try to reactivate the structure once again. And when you open the function module, if the problem still persists just try to press Return key several times. The message you are getting is just a warning message.
PS: I am not sure whether this is the correct way, but i personally resolved this by pressing the ENTER key 4 or 5 times. So just give a try.
Regards
Sunil -
Creation of sales order in CRM and replicating it to Multiple ECC system.
We have a requirement for creation of sales order in CRM and replicating it to Multiple ECC system.
We have checked the following standard Adapter objects in transaction R3AC1.
BUS_TRANS_MSG
The initial flow contexts does not support target site type as R/3(SMOF_ ERPSITE). So we are not able to replicate the sales order from CRM
to ECC.
2. SALESDOCUMENT
Here the initial flow contexts does not support flow from CRM -> R/3 as we don’t see the target site as CRM.
Please let us know if the standard sap middleware objects don’t support the sales order flow from CRM to multiple ECC or is there any
other adapter object we need to use for this.Hey Vijay Duvvada,
I hope you are already referred below sap note and which explains scope & how to do -
1084315 - Consulting: Information about the multiple backend scenario
1763516 - How-to: Basic Setup of MEP
As explained by Rohit Sharma data should be start flowing to multiple sites.
please let me know if it does help.
Regards,
Arjun -
How to find table name for the fields from Standard Extractor in CRM system
How to find table name of fields from the standard extractor in CRM system ?
e.g. We use LBWE TCode in R/3 system to find table name for the field from Extractor VCSCL(e.g.).
Likewise is there any way to find table name for the fields from Standard extractor like 0CRM_LEAD_I.Hi ,
Please find the link below for understanding BW CRM analysis.
http://help.sap.com/bp_biv135/html/bw.htm
activate the CRM DSs by scenario:
1) Activate the application component hierarchy (tcode RSA9). Changes made to the application component hierarchy in the CRM system can be transferred to the BW using the "Edit Application Component Hierarchy" (SBIW - Postprocessing of DataSources).
SAP Note 434886 must be implemented in CRM 3.0 before the application component hierarchy is activated.
2) Activate the Business Content DataSources (tcode RSA5).
Select/enter the application component and choose Execute (F8).
To compare the shipped and active versions, choose the 'Select Delta' pushbutton. If there is no active version of the DataSource, it is selected automatically.
To activate the shipped version, choose the 'Transfer DataSources' pushbutton.
3) Management of the versions of the BW-Adapter metadata (tcode BWA5). All DataSources are displayed that are managed by the BW Adapter.
As in transaction RSA5 (Service API Metadata Activation), the 'Select Delta' function can be used to select the inactive DataSources or compare shipped and active versions.
You can also go directly to the screen for maintaining DataSources that are managed by the BW Adapter.
The 'Compare Version' function makes a detailed comparison of the shipped and active versions.
All BW-Adapter metadata is considered when versions are compared:
Header information (Table SMOXHEAD)
Mapping information (Table SMOXRELP)
Global selection conditions (Table SMOXGSEL)
Attribute key fields (Table SMOXAFLD)
Hope this helps.
Regards,
csm reddy -
How to identify update mode in function module for generic extractor
Hi All,
I have created generic extractor using function module which supports delta load.
Delta logic is handeled in coding...by using ROOSGENDLM table.
Now problem is we need to identify the update mode, requested from infopackage in our function module in order to apply logic for Repair full.
I would like to know table or parameter in source system, which contain the update mode (Init , Delta , Full).
Thanks,
NirajHi Niraj
You can use the FM import parameter "i_updmode" (This is of type "SBIWA_S_INTERFACE-UPDMODE") to determine if infopackage triggerred in full or delta mode.
I_REQUNR TYPE SBIWA_S_INTERFACE-REQUNR
I_ISOURCE TYPE SBIWA_S_INTERFACE-ISOURCE InfoSource Name
I_MAXSIZE TYPE SBIWA_S_INTERFACE-MAXSIZE Data Packet size
I_INITFLAG TYPE SBIWA_S_INTERFACE-INITFLAG Initial Flag
I_UPDMODE TYPE SBIWA_S_INTERFACE-UPDMODE Update Mode
I_DATAPAKID TYPE SBIWA_S_INTERFACE-DATAPAKID Datapacket Id
I_PRIVATE_MODE
I_CALLMODE TYPE ROARCHD200-CALLMODE Single-Character Flag
I_REMOTE_CALL TYPE SBIWA_FLAG
Cheers
Vasu Sattenapalli -
How to reduce long extraction time - Generic extractor based on view
Hello. The previous thread about this error was closed without any answer.
I'm in the same configuration.
"Using a generic extractor (Delta enabled on confirmation date) based on view to load data from ECC6 to BI.
Now my issue is that the delta extraction is running for a long time (around 1 hr) even if the data volume is very small
While checking the job overview in source system i saw that the job is hanging at the below step for almost 1 hr."
1 LUWs confirmed and 1 LUWs to be deleted with function module MF RSC2_QOUT_CONFIRM_DATA.
I am not understanding why this is happening.
Here is the log of the job:
30.05.2011 03:58:11 Job started
30.05.2011 03:58:11 Step 001 started (program SBIE0001, variant &0000000166864, user ID ALEREMOTE)
30.05.2011 03:58:11 Asynchronous transmission of info IDoc 2 in task 0001 (0 parallel tasks)
30.05.2011 03:58:11 DATASOURCE = 0CO_OM_WBS_6
30.05.2011 03:58:11 *************************************************************************
30.05.2011 03:58:11 * Current Values for Selected Profile Parameters *
30.05.2011 03:58:11 *************************************************************************
30.05.2011 03:58:11 * abap/heap_area_nondia......... 4000000000 *
30.05.2011 03:58:11 * abap/heap_area_total.......... 8000000000 *
30.05.2011 03:58:11 * abap/heaplimit................ 100000000 *
30.05.2011 03:58:11 * zcsa/installed_languages...... DEFS *
30.05.2011 03:58:11 * zcsa/system_language.......... E *
30.05.2011 03:58:11 * ztta/max_memreq_MB............ 2047 *
30.05.2011 03:58:11 * ztta/roll_area................ 6500000 *
30.05.2011 03:58:11 * ztta/roll_extension........... 2000000000 *
30.05.2011 03:58:11 *************************************************************************
30.05.2011 03:58:11 1 LUWs confirmed and 1 LUWs to be deleted with function module RSC2_QOUT_CONFIRM_DATA
30.05.2011 05:02:53 Call customer enhancement BW_BTE_CALL_BW204010_E (BTE) with 171 records
30.05.2011 05:02:53 Result of customer enhancement: 171 records
30.05.2011 05:02:53 Call customer enhancement EXIT_SAPLRSAP_001 (CMOD) with 171 records
30.05.2011 05:02:53 Result of customer enhancement: 171 records
30.05.2011 05:02:53 Asynchronous send of data package 1 in task 0002 (1 parallel tasks)
30.05.2011 05:02:53 IDOC: Info IDoc 2, IDoc No. 4667050, Duration 00:00:00
30.05.2011 05:02:53 IDoc: Start = 30.05.2011 03:58:11, End = 30.05.2011 03:58:11
30.05.2011 05:02:53 tRFC: Data Package = 1, TID = AC11082D38B44DE308DD028A, Duration = 00:00:00, ARFCSTATE = RECORDED
30.05.2011 05:02:53 tRFC: Start = 30.05.2011 05:02:53, End = 30.05.2011 05:02:53
30.05.2011 05:02:53 Altogether, 0 records were filtered out through selection conditions
30.05.2011 05:02:53 Asynchronous transmission of info IDoc 3 in task 0003 (0 parallel tasks)
30.05.2011 05:02:53 IDOC: Info IDoc 3, IDoc No. 4667051, Duration 00:00:00
30.05.2011 05:02:53 IDoc: Start = 30.05.2011 05:02:53, End = 30.05.2011 05:02:53
30.05.2011 05:02:53 Synchronized transmission of info IDoc 4 (0 parallel tasks)
30.05.2011 05:02:53 IDOC: Info IDoc 4, IDoc No. 4667052, Duration 00:00:00
30.05.2011 05:02:53 IDoc: Start = 30.05.2011 05:02:53, End = 30.05.2011 05:02:53
30.05.2011 05:02:53 Job finished
Thanks for your help.
YannParth Kulkarni,
following the note and the other thread, I've check the index 4 of the table COEP.
Here is what I got:
Index ID COEP - 4
Short text MANDT/TIMESTMP/OBJNR, Index for Delta read method (CO-PA)
Last changed SAP 04.01.2010
Status Active Saved
Does not exist in the database
DB index nme
Not defined as DB index in the ABAP Dictionary
Is the fact that it doesn't exist in the database a problem ?
Is the fact that it is active is good enough ?
By the way thanks for your speedy reply !
Yann
Edited by: Yann GOFFIN on May 30, 2011 1:35 PM
Maybe you are looking for
-
"Bounce to new track" creates a mixdown 2/3 volume of the original
When I right click and bounce a track to a new track, the resulting Mixdown file shows as only about 2/3 the volume of the original. The original is -1, the Mixdown is -4. It also looks flat and compressed. I have no buses and the volume/pans are all
-
No Web server maintained for the presentation of log. system
Hi Banu/All, I got the following error message while executing jump target to R/3 Transaction ME2N. <i>Messages: No Web server maintained for the presentation of log. system DDVR3110 Jump target cannot be executed An error occurred with the report to
-
I've updated my iphone 5 and have lost all contacts' where can i find them?
i/ve lost contacts after updating to ios6' what can i do?
-
Link to register Oracle XE is broken
Hi, I'm trying to register Oracle XE but the link on the XE home page does not appear to work. The link appears to go to http://www.oracle.com/technology/xe/registration but I get sent to http://www.oracle.com/webapps/dialogue/dlgpage.jsp?p_dlg_id=42
-
Updating elements in a collection
Hey. I'm trying to update the objects in a collection that is displayed on a jsp. Everything loads fine, the collection displayed using logic:iterate, but the on of the fields in each record is a checkbox and on form submit, my changes to the checkbo