Cube 0PP_C03 consists DS 2LIS_04_P_ARBPL(with int. delta), 0PP_WCCP(full)?

Hi,
i have an cube 0pp_c03 having DS 2lis_04_p_arbpl have option full and int. delta update for info package AND 0pp_wccp with full update.
what type of updation for each data source will be ideal?
Is it possible to set delta for DS other than LO - ex: 0PP_WCCP?
Best regards,
dushyant.

Thanks Francisco Milan and Shilpa for the links. Itu2019s very useful. But still I didnu2019t able to find the cause of the issue.
My data source 2LIS_04_P_ARBPL is of ABR type and the update mode for KF is Summation. In the data source level, I am getting the values with before & after image (same entries one with +ve & another with u2013ve) and as I am using the u201CSummation as my update type for KF its getting nullified.
Because of this reason I could not able to get the values in my report. Could any one pls help me on this as I am reaching the go-live date. I need to address this issue immediately. Thanks for all your inputs.
Regards,
Shanthi.

Similar Messages

  • Run Time error while activating the cube 0pp_c03

    Hi All,
    I encountered this error while activating the info cube 0pp_c03
      An exception occurred which is explained in detail below.
      The exception, which is assigned to class 'CX_RSR_X_MESSAGE', was not caught
      and
      therefore caused a runtime error.
      The reason for the exception is:
      No text available for this exception
    Regards
    Rohit

    Hi,
    Please check in ST22 for any relevant short dump. the error message is not of much help in anlyzing the problem
    or
    Perform the consistency test with 'RSRV' -->All Elementary Tests --> Master Data --> 'Compare Number Range and Maximum SID for the characteristic 0REQUID'. and correct the error
    Regards,
    Marasa.

  • Generic Datasource with Additive Delta

    Hi all
    I have a question.
    In whic case can I use a generic datasource with additive delta?
    Does this delta mode make sens only with function module extraction?
    If I extract data directly from a table, can I use this delta mode only if a field represents changes?
    Thanks for your help!
    S.

    Stefania,
        To my knowledge what you are thinking is wrong.
    we have 2 Methods for Generic DS.
    1. New status for changed Records.
    2. Additive delta.
    New status for changed records means
    New Order
    order no    quantity
    1000          10
    order changed to quntity 8. then 2 records will posted 2 BW in first case.
    1000          -10
    1000            8
    if you come to Additve delta.
    for the same case it will send the same record as
    1000          10
    changed records
    1000          -2
    this is the difference. New status with changed records should be used only in association with ODS not cube becoz we don't have overwrite option.
    Additive delta we can use for ODS and Cubes with update mode Addition.
    Hope this is clear.
    Regards,
    Nagesh Ganisetti.

  • Hp laserjet Pro 200 M276nw won't consistently connect wirelessly with iMac

    I'm on my second brand new hp laserjet Pro 200 M276nw in 3 days, it will not consistently connect wirelessly with my newly purchased (8days old) Apple refurbished 27" iMac on OSX 10.9, i7 chip & Fusion Drive.  The hp laserjet will sometimes connect wirelessly immediately after clicking "print" on the iMac, but about half the time it says "printer not connected" & takes 2-4 minutes (or longer) before the devices do connect. I've called hp support many times, they're reset various things via remote takeover of my iMac, the printer will work for a few of minutes but then the same problem returns. AppleCare made sure I have the
    correct Airprint driver installed & also checked my settings, but says they don't know why this is occurring. I've also verified that our newer (6 months old) AT&T router is functioning correctly.
    My older hp laserjet (CM1312nfi MFP) has worked flawlessly since 2009 via USB connection with my old iMac (still on Snow Leopard), I assumed it would continue with the new one, but there is no software update for Mavericks & the scanning feature won't operate on the new iMac. Hp says it is a discontinued model. The new hp laserjet is a successor model to the older one, they are both very similar except for the new wireless feature. 
    I can print fast & wirelessly from the new iMac via a different new hp inkjet printer (8600 series) here in the house. This inkjet printer is less than a month old, I installed it myself for a Windows laptop here, it has never malfunctioned.  Unfortunately it's upstairs & I do not like inkjet print quality, I need a good laserjet here in my office downstairs next to my iMac.

    HI there
    Did you manage to sort this issue out - as I have exactly the same problem.
    Lots of similarities as I also have an inkjet 8600 which works via USB and wirelessly no problems at all!
    I always  buy HP printers as they are usually easy to set up - but this one is making me tear my hair out!
    I've even upgraded to Yosemite and downloaded the new drivers from HP - no success.  The printer will print one page and then become unavailable.
    I can print via USB or wireless direct - but not just via my wireless network which is what I want to do!
    No responses posted - so assume no one has a fix.
    aaaargh!!!

  • How to use INVOKE function with INT parameter types

    Can you tell me how to use invoke function with int parameter type ?

    Pass the int as an Integer.

  • Replacing a K7N2 with a Delta

    My current mobo is a K7N2 and I was wondering if I replace it with a Delta K7N2, would I have to reformat my harddrive? Im not upgrading for fun... rather my normal K7N2 might be damaged.

    just move it and your bits over

  • & operator with int

    hello everyone,
    i am facing a little problem with & operator.
    int a = 0;
    if(a & 0x0001 == 1)
    else
    }now when i try to compile it, compiler says that operator & cannot be applied with int in the if statement but if i write a statement like
    a &= 0x0001;it works fine.
    can anybody tell me that why & operator behaving differently?
    thanks

    init:
    deps-jar:
    Compiling 1 source file to C:\Documents and Settings\NEWUSER\My Documents\NetBeansProjects\JavaLibrary11\build\classes
    C:\Documents and Settings\NEWUSER\My Documents\NetBeansProjects\JavaLibrary11\src\Hello.java:7: operator & cannot be applied to int,boolean
            if(a & 0x0001 == 1)
    1 error
    BUILD FAILED (total time: 0 seconds)

  • Is it only one chance i can initialize array with int [] a={3,2,1}

    is it only one chance i can initialize array with int [] a={3,2,1}
    ===============================
    class InitializeArrayTest
         int [] a;     //i need keep a[] global
         public static void main(String args[])throws IOException
                   //a=new int[] { 3, 2, 1};//can not complie<========why here is wrong
                   a=new int[3];//also can not
                   a={3,2,1};     //I want to use {3,2,1} as data for simple test purpose here for other method
    }

    so if static means only one instance allowed
    for what reason there is no compiler error in the
    coding below
         static int [] preSort;
         public B(int i)
    int []preSort=new int; //<======why no syntax
    You are declaring a new local variable called preSort, which has scope to the end of the constructor.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       

  • Int delta

    hi experts,
    I cannot find the path to delete the int delta in bi7.0
    can any one help me.
    give me steps how to delete int delta.
    thanks
    vijay.

    Hi,
    take a look:
    Multiple Init Requests
    Delete delta init in delta channel?
    Regards
    Andreas

  • Delta and Full Load question for cube and ODS

    Hi all,
    I need to push full load from Delta ODS.
    I have process chain.... in which the steps are like below,
    1. R/3 extractor for ODS1 (delta)
    2. ODS1 to ODS2 (delta)
    3. ODS2 to Cube ---> needs to be full load
    Now when i run process chain by further processing automatically ODS2 does init/delta for Cube.
    How can i make it possible for full load ??
    can any one guide anything in this ?
    Thanks,
    KS

    Hi,
    1. R/3 extractor for ODS1 (delta) :  This is OK, normally you can put the Delta InfoPack in Process Chian
    2. ODS1 to ODS2 (delta): It automatically flow from ODS1 to ODS2 (you need to select Update Data automaticall in the Targets at the time of ODS creation)
    3. ODS2 to Cube ---> needs to be full load  :
    This you create a Update rules from ODS1 to Cube then Create InfoPackage in between ODS2 and Cube then do full loads. You can delete the data in the CUbe before the load ann dthen do Full load to Cube.
    Note: In ODS2 don't select Upadate Data autmaticlly to Data Targets
    Thanks
    Reddy
    Edited by: Surendra Reddy on Nov 21, 2008 1:57 PM

  • Why won't 5 Emacs out of 30 consistently come up with the userlist?

    Hi,
    I have 5 emacs running 10.4.7 (also occurred on 10.4.6) as a part of 30 networked imacs in a school computer lab. The won't consistently come up with the userlist, except when you delete the cache files. The cache files then become corrupted again and we have to repeat the process.
    The network settings appear to be identical between machines and I even recabelled the lab to try and eliminiate the problem - didn't work - looks nice though! Swapping and replacing the switches didn't help either.
    Can anyone come up with a reliable solution?

    On one of the machines experiencing the problem, note down the modification date of one of the cache files, and then look through the computer's log files for entries made around that time; this may or may not identify what is corrupting the files. If that doesn't work, delete the files and set the permissions on the folder which previously contained them to Read Only for all accounts through the Ownership & Permissions section of the Finder's Get Info window; this may solve the issue. If it doesn't, whatever is causing the files to become corrupt is running as root. Further information may be provided by checking which account is listed as the owner of the files in the Get Info window.
    (15598)

  • Kingston, Crucial, Twinmos memory has problem with K7N2-DELTA??

    I need 2*256MB memory for my AMD 2500+XP.
    Kingston, Crucial, Twinmos memory seem to have problem with K7N2-DELTA-ILSR
    Is Samsung good?
    Please do me a favor to choose one brand that fit my mobo in this link:
    http://www.canadacomputers.com/memory.html
    I tried KingMax(SuperRam Series, since they don't have the ram with the model listed in the test report) and Corsair(CMX256A-3200C2) ,both no good for 2*256MB DUAL channel
    Thank you very much

    I think OCZ and Samsung, is mostly work memory,r ight?
    thx
    I think I will try OCZ

  • Serius problem with k7n2 delta 2

    I have problems with my k7n2 delta2 does not recognize a AtlonXP 3000+ was working in this plate, doing tests of overclock,when to restart do not work the processor in this plate but,the motherboard (k7n2 delta 2) works with other processors, and processor 3000+ works with other motherboards, but Athlon 3000+ with k7n2 delta 2 does not work together, I tested of everything recover the bios, to update the bios and nothing, dont change to default, I hope that can help me beforehand thankful.
    tengo problemas con mi k7n2 delta2 no reconoce  un AtlonXP 3000+ que ya estaba trabajando en esta placa madre, haciendo pruebas de overclock, y despues de reiniciarla ya no quiso reconocer el procesador athlon xp 3000+, la placa madre (k7n2 delta 2) trabaja con otros procesadores, y el procesador 3000+ trabaja con otras placas madres, pero el Athlon 3000+ con k7n2 delta 2 no trabajan juntos, ya he probado de todo restaurar el bios, actualizar el bios y nada, parece que no efectua los cambios a default, no se que hacer, espero que me puedan ayudar agradecido de antemano.
    cuando tiene otro cpu enciende correctamente pero cuando le pongo el xp 3000+ no enciende el monitor ni marca ningun error solo no inicias, pero si enciende.      

    Why do you say Bios doesn't go to default options if with other CPUs Mobo turns on ? You must have in mind that each time you replace the CPU you must Clear CMOS to return to default options, and also you should clean HSF base and CPU die from old thermal grease. At least you know both CPU and Mobo works.
    Por qué dices que la Bios no vuelve a las opciones por defecto si la tarjeta madre funciona con otros procesadores ? Debes tener en cuenta que cada vez que cambias de CPU deberías borrar las opciones que entraste en la Bios como también limpiar la base del disipador de temperatura de la CPU y la CPU misma y usar nueva pasta térmica. Al menos sabes que tanto la CPU como la tarjeta madre trabajan.

  • Init & Delta After Full Load

    hii Experts
    I have one doubt please clarify that.
    If i have a Cube and i m pulling data on basis of Full Load . Then i switch to delta load, before that i took the INIT load without data transfer.
    But after a couple of days i need to pull the full load again for that particular period, for that i delete the INIT request & also the Delta request from Cube & PSA. & after full load i want to pull the delta load.
    Now my doubt is how does this process impact on loading process?Is the previous init & delta also have some impact on the current delta loading???
    Thanks in Advance
    Neha

    Hi,
    There is absolutely no problem in doing a full loaf after init delta.
    doing full load doesnt disturb the delta status.
    Here i explain how an init and delta works
    Init and Delta :
    Once you are done with fetching all data from source using fullload, you have to run init.
    all the new records that appear in the source system after init will sit in the delta queue.
    when ever you run delta after the init, all the new records will coime to Bi and once this delta runs succesfully, these records will be cleared from the queue in source system and the new records from then comes to the queue.
    this way, we can be sure that there is no loss of data.
    Full load after delta :
    now comming to your answer, if you run a full load, the data is not fetched from the delta queue and it doesnt disturb the queue in any way. it only brings all the data from soure(according to selection condition). so the delta is not disturbed in any way.
    Repair Full  Request :
    The repair full request acts in the same way as full load in fetching data from source.
    the only difference is in updating the target.
    Rather than updating the data in the request, it checks out for the changes in already loaded data and update if there are any changes (Repairing the data already loaded.
    That means there is no impact of previous init without data transfer in the current delta loading?
    If you go thru the above explanation you can get this answer easily.
    Init is used to set the delta pointer due to which the present delta is working fine.
    Hope this answer helps you,
    Thanks and Regards,
    Srinath.

  • - Differences between delta and full uploads of transactional data

    Hi All,
    This is with refrence to the loading transactional data into the cube.
    I know that delta and full uploads of transactional data into the cube is done for the following reasons.
    1. Delta upload allows change in transactional data (add/delete/modify) for the particular period selected but this is not the same in full upload.
    2. Full upload takes less time compared to delta upload for the particular period.
    Please let me know whether my understanding is correct. Otherwise, please explain these two concepts with examples taking loading transactional data  into the cube.
    Regards,
    Ningaraju

    hi,
      full upload is done to avoid more time to load the data .if u use initilallization then it will take more time to laod the same amount of data when compared to full load.
    however your statement about the delta is correct.
    u can perform delta only after sucessful initiallization.
    so
    1.first full load(to avoid more time0
    2. inirtilallization with zero recored.
    3. delta
    regards

Maybe you are looking for

  • I'd like to wipe out my current LR of all photos and re upload new files.  How do I go about this?

    I'd like to wipe out my current LR of all photos and re upload new files.  How do I go about this?

  • Please Help --PS CS3

    Guys asking for help from Adobe does not work and they are idiots telling me they cant help me, no matter what I do. that is not the point I came begging for help. I understand that once a trial runs out you can not re-install the problem= I instal t

  • Can't connect to wifi after IOS update.  Do you know a solution?

    Loaded the new update and now it is sporatic connections with the wi fi.  I have unplugged the router and all that, still no luck.  It will work normally very briefly, but only briefly after I unplug the router, etc. Do any of you have a solution to

  • LDAP Not Populating

    I can not seem to get LDAP to list the contents of my Directory.app using Address Book 1. I checked to see if Open Directory is running. Yes it is. 2. I am not using DNS only IP address (10.0.7.2) 3. I made sure all authenticating is correct. (No Ker

  • XML, Repeater, dataProvider

    I'm loading an XML file in the format: <page> <questions> <question id="1">Blah</question> <question id="2">More blah</question> </questions> <other_stuff/> </page> I am successfully loading the XML file into the variable pageXML. I'm trying to bind