Custom IDoc During Upgrade

Hi,
Does custom IDoc type gets copied automatically during the SAP Upgrade or do we need to do it manually...
Thank You,
Regards,
Swaroop Patri

Swaroop,
You do not need to copy custom idoc. Since it is customised idoc it will not be overwritten by sap if you have followed proper naming convention..
Nilesh

Similar Messages

  • Impact on Custom / Std IDOC after upgrading from 4.7 to ECC 6.0

    I am in Upgrade project (4.7 to ECC 6.0).
    What will be the impact of the existing Custom and Std IDOC after upgrading from 4.7 to ECC 6.0 and if any impact, what are precautionary steps to be taken to work as it is.
    Will there be any Impact on ALE also ?
    Thanks & Regards
    Khaleel

    closed.

  • After creating successor to a custom IDOC?

    Hello
    We have a custom IDOC type (for sales orders) in the system. Now business want to pass additional data, as per this requirement am trying to add a new custom segment to this custom IDOC, but am getting the below error,
    ZORDR03 has already been released, only display possible
    Message no. E0639
    Diagnosis
    ZORDR03 has already been released. This means that the basic type or extension is locked
    against changes and can only be displayed.
    Procedure
    You can create a successor based on ZORDR03.
    I guess, i can not do CANCEL RELEASE from Memu-->Edit! because this custom IDOC is created in older versions, like 46C, currently we are on ECC6.0, hence i need to create a successor, but pls. let me now
    1) Do I need to change all the config settings like in WE72, WE82, WE20 O/B Prtaner profiles of EDP13?
    2) In what/where else i need to change or replace old ZORDR03  with newley creating ZORDR04?
    Thank you

    You need to be patient - this is not a Helpdesk where you've raised a high priority ticket...
    I'll just say that when we upgraded to ERP6.0, I did not agree with the fact that we could not cancel release on our custom IDOCs and we did not want to create a new version (it's been too long - I don't remember the technical reason for the issue with the new version).  We reset the release in the definition table and made the required changes.  There were no issues with the change.  If you want o go with the 'standard' appraoch, create a new version...

  • Error while runnning autoconfig on apps tier during upgrade

    Hi,
    Error while runnning autoconfig on apps tier during upgrade from 11.5.9 to 11.5.10.2
    below is the error message.
    Enter the APPS user password :
    The log file for this session is located at: /u01/app/tinst/tinstappl/admin/TINST_dba5/log/05031134/adconfig.log
    AutoConfig is configuring the Applications environment...
    AutoConfig will consider the custom templates if present.
    Using APPL_TOP location : /u01/app/tinst/tinstappl
    Classpath : /u01/app/tinst/tinstcomn/util/java/1.6/jdk1.6.0_18/jre/lib/rt.jar:/u01/app/tinst/tinstcomn/util/java/1.6/jdk1.6.0_18/lib/dt.jar:/u01/app/tinst/tinstcomn/util/java/1.6/jdk1.6.0_18/lib/tools.jar:/u01/app/tinst/tinstcomn/java/appsborg2.zip:/u01/app/tinst/tinstcomn/java
    Using Context file : /u01/app/tinst/tinstappl/admin/TINST_dba5.xml
    Context Value Management will now update the Context file
    Exception in thread "main" java.lang.NoClassDefFoundError: oracle/jdbc/OracleDriver
    at oracle.apps.ad.util.DBUtil.registerDriver(DBUtil.java:153)
    at oracle.apps.ad.util.DBUtil.<init>(DBUtil.java:102)
    at oracle.apps.ad.tools.configuration.FileSysDBCtxMerge.getDBConnection(FileSysDBCtxMerge.java:759)
    at oracle.apps.ad.tools.configuration.FileSysDBCtxMerge.initializeParams(FileSysDBCtxMerge.java:147)
    at oracle.apps.ad.tools.configuration.FileSysDBCtxMerge.setParams(FileSysDBCtxMerge.java:128)
    at oracle.apps.ad.context.CtxValueMgt.mergeCustomInFiles(CtxValueMgt.java:1762)
    at oracle.apps.ad.context.CtxValueMgt.processCtxFile(CtxValueMgt.java:1579)
    at oracle.apps.ad.context.CtxValueMgt.main(CtxValueMgt.java:709)
    Caused by: java.lang.ClassNotFoundException: oracle.jdbc.OracleDriver
    at java.net.URLClassLoader$1.run(URLClassLoader.java:202)
    at java.security.AccessController.doPrivileged(Native Method)
    at java.net.URLClassLoader.findClass(URLClassLoader.java:190)
    at java.lang.ClassLoader.loadClass(ClassLoader.java:307)
    at sun.misc.Launcher$AppClassLoader.loadClass(Launcher.java:301)
    at java.lang.ClassLoader.loadClass(ClassLoader.java:248)
    ... 8 more
    ERROR: Context Value Management Failed.
    Terminate.
    The logfile for this session is located at:
    /u01/app/tinst/tinstappl/admin/TINST_dba5/log/05031134/adconfig.log
    Please let me know your suggestions to resolve this issue.
    Regards,
    Sreenivasulu.

    Hi,
    DB tier autoconfig was successfully completed.
    We have already checked the above mentioned metalink ID's, but still the issue is same.
    Can you please advice any other solutions.
    Regards,
    Sreenivasulu.

  • Could you pls give the details about the Unicode conversion during Upgrade

    Hi,
    Can anyone give details about the Unicode conversion during SAP Upgradation fro 4.6C to ECC6.
    Waiting for quick response
    Best Regards,
    Padhy

    Hi,
    These are the few points i gathered during my upgradation project.
    Before starting any upgradation project, it is necessary to take up the back-up of the existing systems. As we are going to upgrade the entire system, we will be changing so many things and if something happens, without back-up, we will be in a trouble.
    So it is advised to keep a back-up of the existing system.
    Say for example we have the existing system E4B which is of Version 4.6C. Now we want to upgrade it to Version 4.7. Let us see how we can do it.
    Version upgrades not only means that we need to run the new Version CD over the existing Version System but only involves some other thing.
    Version Upgrade involves the following Steps.
    Say we want to upgrade for Version 4.7 from Version 4.6, which is in the System E4B. Now we created one more system called as E1B in which the upgradation for Version 4.7 can be done.
    • First copy the entire E4B system into the E1B System which is created for Version 4.7.
    • Apply the Version 4.7 CD provided by SAP over the E1B System.
    • Now check whether all the functionalities that was in E4B system works fine with E1B system also.
    Thus the Version Upgrade involves two steps.
    1. SAP Upgradation with the help of the CD
    2. Manual Upgradation.
    1. SAP Upgradation with the help of the CD
    This is nothing but after taking the copy of the existing system into a new system, the upgradation CD from SAP is applied over the new system.
    2. Manual Upgradation.
    This Manual Upgradation involves
    2.1 Upgradation of Standard Objects
    2.1.1 SPAU Objects
    2.1.2 SPDD Objects
    2.2 Upgradation of Custom Objects.
    Upgradation of Custom Objects can be placed under the following three categories.
    Unicode Compliance
    Retrofit
    Upgrade
    Please Find below some of the common Unicode Errors and their solutions
    1. Error:
    In case of Translate Error; ‘Dangerous use of Translate in Multilingual system.’
    Correction:
    To correct the Error occurring on TRANSLATE statement – use this additional statement before the Translate statement.
    SET LOCALE LANGUAGE sy-langu.
    This statement defines the Text Environment of all the programs & internal sessions in the language specified in the LANGUAGE KEY, which in this case is “sy-langu”, i.e. the log on language of the user.
    2. Error:
    In case of Open Dataset Error; ‘Encoding Addition must be included.’
    Correction:
    This Error occurs only when the MODE is TEXT.
    To correct the Error occurring on OPEN DATASET statement – use this statement instead.
    OPEN DATASET dataset_name FOR access IN TEXT MODE ENCODING DEFAULT.
    Where: dataset_name – NAME OF THE DATASET.
    Access – INPUT or OUTPUT or APPENDING or UPDATE.
    DEFAULT - Corresponds to UTF-8 in UNICODE systems &
    NON_UNICODE in NON-UNICODE systems.
    3. Error:
    In case of the usage of the Obsolete FM UPLOAD/DOWNLOAD or WS_UPLOAD/DOWNLOAD; ‘Function module UPLOAD is flagged as obsolete.’
    Correction:
    The FM GUI_DOWNLOAD/UPLOAD is used.
    The variations to be made in the parameters of the FM:
    1. Filename – It must be of STRING type.
    2. Filetype – “DAT” is not used any longer, instead “ASC” is used.
    3. Field Separator – The default value “SPACE” is used, incase for a TAB separated file “X” can be used.
    4. Error:
    In case of CURRENCY/UNIT Addition Error; ‘Use addition CURRENCY/UNIT when outputting.’
    Correction:
    The CURRENCY addition specifies the currency-dependant decimal places for the output of the data objects of type i or p. To obtain the currency-key, the field CURRKEY of the table TCURX is used. The system determines the number of the decimal places from the field CURRDEC of the selected CURRKEY.
    To correct this error follow the following method:
    WRITE: /3 'TOTAL',' ', TOTAL.
    WRITE: /3 ‘TOTAL’,’ ‘, TOTAL CURRENCY ‘2’. --- Where ‘2’is the Currency Key for Getting 2 decimal places.
    5. Error:
    In case of TYPE X Error; ‘Variable must be of C, N, D, T or STRING type.’
    Correction:
    We need to change all the Type X (Hexadecimal) variables to Type C with their values unchanged.
    So the method to be followed is:-
    1. Load the definition of the class CL_ABAP_CONV_IN_CE or CL_ABAP_CHAR_UTILITIES.
    2. Declare the variable as Type C, and use the method UCCP(‘XXXX’) of the class CL_ABAP_CONV_IN_CE where XXXX represents the 8-bit Hexadecimal value and incase the variable holds a Hex value for a Horizontal Tab , then the Attribute “HORIZONTAL_TAB” of the class CL_ABAP_CHAR_UTILITIES can be used directly instead of using the method UCCP.
    E.g.:
    i) *DATA: TAB TYPE X VALUE 09, “Tab character
    CLASS: CL_ABAP_CHAR_UTILITIES DEFINITION LOAD.
    DATA TAB TYPE C VALUE CL_ABAP_CHAR_UTILITIES=>HORIZONTAL_TAB.
    ii) * DATA: CHAR TYPE X VALUE 160.
    CLASS: CL_ABAP_CONV_IN_CE DEFINITION LOAD.
    DATA CHAR TYPE C.
    CHAR = CL_ABAP_CONV_IN_CE=>UCCP(‘00AO’).
    (Here ‘00A0’ is the Hexadecimal equivalent of the decimal 160).
    3. Incase the TYPE X Variable has a length more than 1, then an internal table must be created for the variable.
    E.g.:
    CLASS: CL_ABAP_CONV_IN_CE DEFINITION LOAD.
    DATA : LF(2) TYPE X VALUE 'F5CD'.
    DATA : BEGIN OF LF,
    A1 TYPE C,
    A2 TYPE C,
    END OF LF.
    LF-A1 = CL_ABAP_CONV_IN_CE=>UCCP('00F5').
    LF-A2 = CL_ABAP_CONV_IN_CE=>UCCP('00CD').
    6. Error:
    In case of the Character “-“Error; ‘The Character “-“can’t appear in names in Unicode Programs.’
    Correction:
    The Character “-“(Hyphen) appearing in Variable names is replaced by the character “_” (Under Score) for Unicode/Upgrade Compliance.
    E.g.:
    *wk-belnr LIKE bkpf-belnr,
    *wk-xblnr LIKE bkpf-xblnr,
    *wk-date LIKE sy-datum,
    *wk-wrbtr LIKE bseg-wrbtr,
    *wk-name1 LIKE lfa1-name1,
    *wk-voucher(8) TYPE c.
    wk_belnr LIKE bkpf-belnr,
    wk_xblnr LIKE bkpf-xblnr,
    wk_date LIKE sy-datum,
    wk_wrbtr LIKE bseg-wrbtr,
    wk_name1 LIKE lfa1-name1,
    wk_voucher(8) TYPE c.
    7. Error:
    In case of The SUBMIT-TO-SAP-SPOOL Error; ‘you should not use the statement SUBMIT-TO-SAP-SPOOL without the WITHOUT SPOOL DYNPRO addition. ‘
    Correction:
    1. Declare variables of type PRI_PARAMS, ARC_PARAMS, and a variable of TYPE C which would be used as a VALID FLAG.
    2. Call the FM GET_PRINT_PARAMETERS:
    CALL FUNCTION 'GET_PRINT_PARAMETERS'
    EXPORTING
    ARCHIVE_MODE = '3'
    DESTINATION = P_DEST
    IMMEDIATELY = 'X'
    IMPORTING
    OUT_ARCHIVE_PARAMETERS = archive_parameters
    OUT_PARAMETERS = print_parameters
    VALID = valid_flag
    EXCEPTIONS
    INVALID_PRINT_PARAMS = 2
    OTHERS = 4
    3. Use the SUBMIT-TO-SAP-SPOOL statement.
    E.g.:
    •     submit zrppt500
    •     using selection-set 'AUTO3'
    •     with res_no eq lo_rsnum
    •     with sreserv in preserv
    •     to sap-spool destination p_dest
    •     immediately 'X'. "print immediate
    DATA: print_parameters type pri_params,
    archive_parameters type arc_params,
    valid_flag(1) type c.
    CALL FUNCTION 'GET_PRINT_PARAMETERS'
    EXPORTING
    ARCHIVE_MODE = '3'
    DESTINATION = P_DEST
    IMMEDIATELY = 'X'
    IMPORTING
    OUT_ARCHIVE_PARAMETERS = archive_parameters
    OUT_PARAMETERS = print_parameters
    VALID = valid_flag
    EXCEPTIONS
    INVALID_PRINT_PARAMS = 2
    OTHERS = 4
    Submit zrppt500
    Using selection-set 'AUTO3'
    With res_no eq lo_rsnum
    with sreserv in preserv
    to sap-spool
    SPOOL PARAMETERS PRINT_PARAMETERS
    ARCHIVE PARAMETERS ARCHIVE_PARAMETERS
    WITHOUT SPOOL DYNPRO.
    8. Error:
    In case of Message Error; ‘Number of WITH fields and number of Place Holders are not same ‘.
    Correction:
    Split the statement after WITH into the same number as the place holder for that Message ID.
    E.g.:
    1. * MESSAGE E045.
    MESSAGE E045 WITH '' ''.
    2. in program ZIPI0801
    •     Start of change for ECC6
    •     message e398(00) with 'Could not find access sequence'
    •     'for condition type:'
    •     p_ptype.
    message e398(00) with 'Could not find '
    'access sequence'
    'for condition type:'
    p_ptype.
    •     End of change made for ECC6
    9. Error:
    In case of Move between 2 different Structures; ‘The structures are not mutually convertible in a Unicode program.’
    Correction:
    Make both the Data Types compatible and then assign the contents.
    E.g.:
    The statement –“move retainage_text to temp_text.” Gives an error, where RETAINAGE_TEXT is an internal table and TEMP_TEXT is a string of length 200.
    A Feasible solution for this is to specify from which position to which position of the string, the fields of RETAINAGE_TEXT should be assigned.
    TEMP_TEXT+0(1) = RETAINAGE_TEXT-DQ1.
    TEMP_TEXT+1(1) = RETAINAGE_TEXT-HEX.
    TEMP_TEXT+2(20) = RETAINAGE_TEXT-FILLER1.
    TEMP_TEXT+22(15) = RETAINAGE_TEXT-AMT_DUE.
    TEMP_TEXT+37(8) = RETAINAGE_TEXT-TEXT.
    TEMP_TEXT+45(10) = RETAINAGE_TEXT-DUE_DATE.
    TEMP_TEXT+55(1) = RETAINAGE_TEXT-DQ2.
    10. Error:
    In case of ‘no description found’; ‘add a GUI title’.
    Correction:
    In this type of error gui title is generally missing so add a GUI title to the module pool.
    11. Error:
    In case of ‘writing internal or transparent table’
    Correction:
    Write individual fields.
    E.g.:
    WRITE: / EXT. --> EXT should be a character type field
    WRITE: / EXT-ZZSTATE, EXT-LINE_NO, EXT-LINE_TXT, EXT-AMT, EXT-ZZSKUQTY.
    12. Error:
    In case of ‘combination reference table/field S541-UMMENGE does not exist’
    Correction:
    Was due to error in reference table S541. TABLE S541 has errors
    1)”Foreign key S541- ZZMARKET (ZZMARKET AND KATR2 point to different domains)”
    2)”Foreign key S541-ZZACQUIGRP (ZZACQUIGRP AND KATR8 point to different domains)”
    Changed the domain of ZZMARKET (from ZMKCODE to ATTR2)
    And that of ZMKCODE (from ZACCODE to ATTR8)
    13. Error:
    In case of ‘KEY does not exist’
    Correction:
    The reference table for field KBETR was KNOV earlier changed it to RV61A as KNOV was in turn referring to RV61A.
    14. Error:
    Incase of ‘WRITE’ statement, ‘Literals that take more than one line is not permitted in Unicode systems.’
    Correction: To correct this error, we need to align the spaces accordingly so that the statement doesn’t go beyond the line.
    15. Error:
    Incase of Data statement, ‘The data type ZWFHTML can be enhanced in any way. After a structure enhancement, this assignment or parameter might be syntactically incorrect………..’
    Correction: To correct this error, instead of “like” in the Data statement, use “type”.
    16. Error:
    Incase of DESCRIBE statement, ‘DESCRIBE can be used only with IN BYTE... Or IN CHARACTER mode in Unicode systems.’
    Correction: To correct this error, use additional text, IN BYTE MODE / IN CHARACTER MODE along with this statement.
    CHARACTER MODE is added when the data object is of flat/ character type.
    BYTE MODE is added when the data object is a deep structure.
    Syntax: DESCRIBE FIELD data_obj : LENGTH blen IN BYTE MODE,
    LENGTH clen IN CHARACTER MODE.
    Where blen and clen must be of type I.
    17. Error:
    Incase of DO-LOOP Error,’ In Do loop range addition needed‘
    Correction:
    An internal tables is declared and the two fields (VARYING field and NEXT field) were
    Included inside the internal table
    E.g.: In program SAPMZP02
    DO 11 TIMES
    •     VARYING STATION_STATE FROM STATION1 NEXT STATION2. “ECC6
    CASE SYST-INDEX.
    WHEN ‘1’
    STATION_STATE = STATION1.
    WHEN ‘2’
    STATION_STATE = STATION2.
    WHEN ‘3’
    STATION_STATE = STATION3.
    WHEN ‘4’
    STATION_STATE = STATION4.
    WHEN ‘5’
    STATION_STATE = STATION5.
    WHEN ‘6’
    STATION_STATE = STATION6.
    WHEN ‘7’
    STATION_STATE = STATION7.
    WHEN ‘8’
    STATION_STATE = STATION8.
    WHEN ‘9’
    STATION_STATE = STATION9.
    WHEN ‘10’
    STATION_STATE = STATION10.
    WHEN ‘11’
    STATION_STATE = STATION11.
    18. Error:
    Incase of the parameter QUEUE-ID Error,’ QUEUE-ID’ is neither a parameter nor a select option in program rsbdcbtc.’
    Correction:
    The parameter in program rsbdcbtc is QUEUE_ID and so is changed in this program
    E.g.: In program Z_CARRIER_EDI_INTERFACE
    •     submit rsbdcbtc with queue-id = apqi-qid and return. "ECC6
    •     The parameter name changed by replacing '-' with '_' as in program rsbdcbtc "ECC6
    Submit rsbdcbtc with queue_id = apqi-qid and return. "ECC6
    19. Error:
    Incase of EPC Error,’ Field symbol <TOT_FLD> is not assigned to a field ‘.
    Correction:
    This error couldn't be rectified as the error occurs in a Standard SAP include- LSVIMF29.
    The OS Note - 1036943 needs to be applied.
    Error:
    OPEN DATASET P_FILE FOR OUTPUT IN TEXT MODE.
    Correct:
    OPEN DATASET P_FILE FOR OUTPUT IN TEXT MODE ENCODING DEFAULT.
    Error:
    Constants : c_tab type x value '09' .
    Correct:
    Constants : c_tab type abap_char1 value cl_abap_char_utilities=>horizontal_tab .
    Error:
    Data : begin of output_options occurs 0 . Include structure ssfcompop.
    Data : end of output_options .
    Correct:
    Data : output_options type standard table of ssfcompop with header line .
    Error:
    PARAMETERS : NAST TYPE NAST .
    Correct:
    PARAMETERS : NAST TYPE NAST NO-DISPLAY .
    Replace WS_DOWNLOAD and WS_UPLOAD by
    GUI_UPLOAD and GUI_DOWNLOAD and check the import and export parameter types , do the changes accordingly. Because FILENAME paramater type is different because of this it will give dump.
    For issue during Issue using SO_NEW_DOCUMENT_ATT_SEND_API1 Function module, the solution is After this FM we should put COMMIT WORK.
    Issue:
    Moving data from one structure to another structure if those two structures are not compatible
    Solution:
    we should use move-corresponding or field by filed we need to move it.
    If database structures are different in 4.6c and ECC6.0,
    Then we should go with append structure concept.
    While testing the report if it gives dump at Select query level or any database or view level,then just goto that table or view and goto the data base utility(se14) adjust the database. But make sure that selected radio button in se14 transaction should be activate and adjust database
    Also Check this link.
    http://help.sap.com/saphelp_nw04/helpdata/en/62/3f2cadb35311d5993800508b6b8b11/frameset.htm
    Reward points if helpful.
    Regards,
    Ramya

  • Preserving customization during upgrade

    Hi,
    Are there any special steps which need to be done to preserver the customization during upgrade.
    Thanks,
    Taher

    Taher,
    Are you referring to the upgrade from 11i to R12? If yes, see below:
    Are there any special steps which need to be done to preserver the customization during upgrade.For the database objects, you have to validate all those objects after the upgrade and test it all. Since many changes happen to the seeded database objects, many of the objects become obsolete so you will have to test your custom code and make sure all is working as expected (if you follow the customization naming convention, then should be easy to be done).
    For custom forms/reports, please refer to:
    How To Upgrade 11i Custom Forms To R12 [ID 563258.1]
    Do Not Compile EBS R12 Reports Using rwconverter.sh or Reports Builder from IDS 10gR2 [ID 786794.1]
    Using the OracleAS 10.1.2 Forms and Reports Builders with Oracle Applications Release 12 [ID 444248.1]
    Thanks,
    Hussein

  • Table Maintenance, during upgrades

    Experts,
    How do we handle table maintenance generator screens and t-codes during upgrades (for Z tables)? Do they come up in the SPAU list post upgrade or is there anything to do in SPDD during ACT_<version> stage?
    Tx, in adv.

    Hi,
    Shaji is correct. Table maintenances are corrected after the upgrade is applied by the BASIS team. You will just have to re-test those table maintenances.
    If you are also doing Unicode Conversion as well. Then you need to make sure to set Unicode Checks Active for the function pool related to your table maintenance.
    i.e you have in table maintenance stored in function group ZMYFUNC. Then you need to go to the "generated" function pool SAPLZMYFUNC and set Unicode Checks Active.
    Unless your table maintenances have lots of custom logic in them, you generally would not encounter any errors at all.

  • Is it possible to create a custom IDOC status?

    Is it possible to create a custom idoc status on table TEDS1?
    I have looked through customising and cannot seem to find a way to create a new idoc status.
    Has anybody done this?

    Hello Chester..
    hope this link will be helpful,
    Re: IDOC status
    *********Please reward points ,if found useful

  • Error during Upgrade from 4.6c to ECC 6.0

    Hi All,
      We are facing an error when upgrading from 4.6c to ECC 6.0. We are facing this error on the table COEP - runtime object inconsistancy. What we found is there is ERP upgrade has created new extra fields in the table. In log file the error is specified as : Duplicate Field name, But we not able to find the duplicate field name in the table.  Please kindly help as early as possible. The upgrade process is stuck.
    Regards
    Anil Kumar K

    Hi Anil,
    Is this issue fixed? Can i know how you fixed it?
    replied to your message Re: How to adopt the index changes during upgrade.
    Thanks,
    Somar

  • Error with Custom Idoc

    Hi All,
    I have created a custom idoc for creation of master data in the system. This custom idoc is using a custom function module to process the idocs. In the FM i have used Call transaction method to upload the master data in the sap system. Everything seems to be working fine.
    But the problem is that whenever any external system creates more than one idoc, first idoc is posted successfully while others fail with an error message "No status record was passed to ALE by the application.". Please let us know how we can resolve it.
    Correct Answers will be rewarded.
    Regards,
    Sridhar.

    Hello
    Refer to following thread:
    The specified item was not found.
    Thanks
    Amol Lohade

  • Creation of Custom IDoc with Message control for sales Order

    Hi all,
    I am trying to create custom Outbound IDoc with message control.
    I wrote the code in a function module and i want to register that function module. (as in inbound registration of function module as in BD51).I am not knowing if that registration is necessary for outbound Idoc, if so in which transacition?
    Please list me the steps to create a custom IDoc for Message control.
    Thanks in advance,
    Regards,
    John.

    Hi,
    You need to use FM : MASTER_IDOC_DISTRIBUTE to create outbound idoc.fill the data in the tables EDIDC,EDIDD and generate the IDOC.
    check this link:
    Re: Master_IDoc_Distribute
    and use transaction : WEDI for IDOC configurations.
    here you will have all the transactions(step by step) to set the outbound IDOC configurations.
    Regards
    Appana

  • Error in transaction KEA0 during upgrade

    Dear All,
    During upgrading the custmer system from 4.7 to ECC 6.0 we found some error in the transaction KEA0 while trying to activate the cross client for an operating concern.
    The activation logs says that there are the syntax errors in the gereted subroutine pool: RK2O0100.
    I however corrected the error and activated the code but again when I am trying to execute the same it gave me the same error and when I go to the sub routine pool I found that the changes are again undone and the previos version is activated. This happens repeatedly that the code is corrected and activated by me and says no error and ones I log off and login again it says the same error.
    Help will be appriciated.
    Thanks iin advance....
    Abhi...

    Dear Raymond,
    Thankds for your help..........
    I tring to run RKEAGENV it shows the error message with STOP button saying that the field WTGBTR not contained in the nametab for table CE1E_B1 and when Io run RKEAGENF it gives a short dump saying that entry for CE10100 is not allowed for TTABS.....
    Please help.

  • Regarding Creation of Custom IDOC

    Hi,
    This is Abdullah Shaik. I want to create an IDOC from the existing IDOC. Some times I need to add some segments to the existing IDOC. Can anybody plz let me know the process how to create the Customized IDOC from the Standard IDOC?
    Thanks & Regards,
    Abdullah shaik.

    Hi Abdullah,
    There are basically two types of IDOCs:-
    Basic IDOCs and Extended IDOCs
    Basic IDOC type defines the structure and format of the business document that is to be exchanged between two systems.
    Extending the functionality by adding more segments to existing Basic IDOCs.
    Creation of IDOC
    To Create Idoc we need to follow these steps:
    Create Segment ( WE31)
    Create Idoc Type ( WE30)
    Create Message Type ( WE81)
    Assign Idoc Type to Message Type ( WE82)
    Creating a Segment
    Go to transaction code WE31
    Enter the name for your segment type and click on the Create icon
    Type the short text
    Enter the variable names and data elements
    Save it and go back
    Go to Edit -> Set Release
    Go thro' this link:-
    http://help.sap.com/saphelp_46c/helpdata/en/dc/6b835943d711d1893e0000e8323c4f/content.htm
    I hope this provides you a solution.
    Regards.
    Praveen

  • Development of custom IDOC's

    Hi All,
    Can we go for approach of developing custom IDOC's? where in our scenarios are getting files from thrid party and updating data in file  into ECC.
    Approach towards Custom IDOC's is for error monitoring and recprocessing.
    Would request your inputs and suggesions in this regard.
    Is that good approach for going to custom idocs? if not why?
    Thanks,
    chandra.

    Hi,
    SAP R/3 systems send out data through IDoc (Intermediate Document), which in internally has segments and fields containing the data. But sometimes, these fields are not sufficient for a specific end-to-end business scenario as far as data transfer is concerned. So in such scenario, either few fields are to be added or subtracted, or completely new structure- IDoc needs to be created.
    At times because of the business scenario we do have to create Custom idocs .
    Regards,
    Bhanu

  • PROBLEM IN CUSTOM IDOC CREATION

    Hi Friends,
                    I'm facing a problem in custom idoc creation plz try to assist me
    1.As per the information i have  i'm creating segment in we31
    for cremas01 idoc.But when i enter the name for segment i'm getting message "Name range Voilation particular name which i had given is not permitted in customer system?
    Plz clarify this,and are there any formalities which i should look for before creating custom idoc?
    Good answers will be rewarded.
                                                                              Regards,
                                                                               Vinod.

    The Problem might be.... with the naming of the segment.
    Standard segments should be created with 'E1' and all the custom segments are created using 'Z1' and the name with 8 characters long only is permitted.
    Reward Points if useful.

Maybe you are looking for

  • Freeware app to extract audio from a DVD?

    Hello all, Is there a freeware program I can use with OSX.3.9 to pull bits of audio from a DVD? Say about 30 seconds here, and 20 seconds there from a couple of different DVD's is all I need. Fingers crossed, I'm on a bit of a tight schedule with thi

  • Sender UID validation

    Hi I have configured messaging server 7.0 in Solaris 10 on single host. We need help to send internal mail by validated UID only. We have configured more then one domain. Is it possible? If yes, what steps require? Pl. reply. Thanks Prem

  • ANNOUNCE: JRockit downloads available on Oracle Technology Network

    JRockit downloads are now available to the community again: http://www.oracle.com/technology/software/products/jrockit/index.html We will soon post a FAQ on this page explaining some of the changes in JRockit's status, but a couple of the most obviou

  • Ram Preview Stops

    Hi, I'm a beginning editor and I'm working on a promotional video and I've used several effects like twitch twixtor magic bullet looks and glow on this video so far, but when I ram preview to check the syncing it only ram previews the first text laye

  • Another "sound doesn't play out of right side of headphones" topic.

    I don't know why this happens. My friend, who knows a crapload more about audio and electronics than I do doesn't know the exact reason why this is happening. Nothing in the headphones port has been badly damaged, yet I've only had my video iPod for