Custom infotype in PPOME

Dear friends,
I have added custom OM infotype in PPOME as a new tab page.
if i create any organisational unit in ppome, i want to know the immidiate parent organisational unit (ie. Objid of the parent org unit) of this newly created org unit.
Also if the cursor is on some other org unit other than the newly created org unit.
then i am not able to get the objid of this newly creatd org unit in PBO or PAI of
my custom infotype screen.
Any help will be highly rewarded.
Thanks,
Vijay.

Dear friends,
I have added custom OM infotype in PPOME as a new tab page.
if i create any organisational unit in ppome, i want to know the immidiate parent organisational unit (ie. Objid of the parent org unit) of this newly created org unit.
Also if the cursor is on some other org unit other than the newly created org unit.
then i am not able to get the objid of this newly creatd org unit in PBO or PAI of
my custom infotype screen.
Any help will be highly rewarded.
Thanks,
Vijay.

Similar Messages

  • Error for custom infotype in PPOME

    Hello Experts,
    I have created one custom OM infotype for object position.Now when i am trying to acccess that Infotype in PO13 it is working fine but when i am trying to acccess the custom infotype in PPOME it is giving a dump.
    EERROR:
    Error in the ABAP program "SAPLRHOMDETAIL_PP01" had to be terminated because it has come accross a statement which cannot be exceuted.
    An exception occurred.
    The exception, which is assigned to class 'CX_SY_ASSIGn_CAST_UNKNOWN_TYPE', was not caught in procedure "INIT_SUBSCREEN" "(FORM)" nor was it propagagted by raising clause exception.
    The reason for the exception is :
    The type "" dynamically specified with ASSIGN....CASTING TYPE is unknown.
    Please guide me where i am doing mistake.
    Thanks in advance.
    Shweta

    Hi Sudha,
    PM01 is the tcode.
    Similar questions were already answered in the following threads
    ABAP HR : Infotype Enhancement
    So please search and then post specific queries.
    rgds
    gayathri

  • Adding a customer infotype in PPOME

    Hello experts,
    I'am trying to add a new customer infotype to PPOME, which should be displayed for all nodes of type "O" - so far, so good. I created the Structure HCI9600 and then I used PPCI without any problems. The new infotype is a part of PPOME, but when I want so save the data, the transaction dumps saying "DYNP_WRONG_SCREEN_TYPE". This is because the screen of the infotype to be processed is a subscreen (Dynpro 7000 of the generated module pool). But I cannot switch the Dynpro to normal dynpro because the PPOME then dumps immediatly.
    So what to do? Nothing found in the OSS...
    Thank you
    T.
    Sorry, the question is solved - never use dynpro 7000!
    Edited by: Thomas Frühling on Sep 12, 2010 8:58 PM

    Hello experts,
    I'am trying to add a new customer infotype to PPOME, which should be displayed for all nodes of type "O" - so far, so good. I created the Structure HCI9600 and then I used PPCI without any problems. The new infotype is a part of PPOME, but when I want so save the data, the transaction dumps saying "DYNP_WRONG_SCREEN_TYPE". This is because the screen of the infotype to be processed is a subscreen (Dynpro 7000 of the generated module pool). But I cannot switch the Dynpro to normal dynpro because the PPOME then dumps immediatly.
    So what to do? Nothing found in the OSS...
    Thank you
    T.
    Sorry, the question is solved - never use dynpro 7000!
    Edited by: Thomas Frühling on Sep 12, 2010 8:58 PM

  • Add custom infotype on ppome

    Hi all,
    I'm struggling with adding a custom infotype (tab) to a position in transaction PPOME.
    I searched on sdn and the net, but I'm not able to find a solution.
    Problem is that the tab is displayed, but there's only the message 'no subscreen found' displayed.
    I've done following steps :
    - created the infotype using PM01
    - created subscreen 7000 using PPCI
    - added subscreen 7000 in table T77ID
    - adapt the sequence of the framework in SPRO
    I'm sure that I'm missing something, but what ?
    Thanks for the help !
    best regards,

    Hello,
    Note 327614 and 385019 might help troubleshoot your issue
    Kind regards
    Sarah

  • PPOME custom infotype

    Dear friends,
    I have added custom OM infotype in PPOME as a new tab page.
    if i create any organisational unit in ppome, i want to know the immidiate parent organisational unit (ie. Objid of the parent org unit) of this newly created org unit.
    Also if the cursor is on some other org unit other than the newly created org unit.
    then i am not able to get the objid of this newly creatd org unit in PBO or PAI of
    my custom infotype screen.
    Any help will be highly rewarded.
    Thanks,
    Vijay.

    Hello,
    Note 327614 and 385019 might help troubleshoot your issue
    Kind regards
    Sarah

  • Error while creating a query for my custom infotype

    Hi,
    I have created a custom infotype with fields currency amount and currency field .
    While I am creating a query for it its giving an error
    Message no. AQ_AD_HOC221 Error when generating the report(see long text )
    I tried to execute the standard program RPUMS40CCI but still I am facing same error .
    I have also maintained table T777i for my infotype but still problem exists.
    Please help.
    P

    Hi
    Check in PM01

  • Error while editing an automaticlly populated record of  a custom infotype

    hi,
    a query in HR ABAP.
    i have created a custom Infotype to store the CTC details of an employee. this custom IT needs to get the records auto populated, when they are created in Infotype 0008.
    i have used the exit. EXIT_SAPFP50M_002  inside which  an include program is written  :ZXPADU02
    using this, the records made to get create automatically in the custom IT.
    but when we try to modify or delete those records thru the tcode PA30,
    it does not allow to do so and throws a standard error message. as  below.
    Specified subtype is invalid
    Message no. PG088
    please help me out to fix this issue.

    the exact point of the std error is,
    i do the folowing steps.
    1)_ for auto creating a record in custom IT Pa**** , i goto transaction, PA30, create record in IT 0008 with a basic Pay., click on save.
    on saving , the EXIT_SAPFP50M_002 is called where i ve written a Z inlcude Program, which inserts the record in custom IT PA****.  this is successful.
    2) when i try to change or delete the same record which i ve created as above, through the Tcode PA30 for custom IT, PA
    ****, i get the error.
    hope the problem is clearly mentioned

  • About to use HR_INFOTYPE_OPERATION to create customer infotype issue:

    hi
    i want to create infotype use function(HR_INFOTYPE_OPERATION).
    this infotype is customer infotype.
    the first scenario is:
      i'm be sure no data about one employee in this infotype(9004).
      to call with data upload function and put data into internal table IT_PA9004.
      and the table data as follow:
    one line: it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080201' , it_pa9004-endda = '20080930'
              it_pa9004-zzvalue = 50 (customer field).
    two line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080201' , it_pa9004-endda = '20080930'
              it_pa9004-zzvalue = 60 (customer field).
    three line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080101' , it_pa9004-endda = '20081031'
              it_pa9004-zzvalue = 70 (customer field).
    four line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080101' , it_pa9004-endda = '20081031'
              it_pa9004-zzvalue = 80 (customer field).
    i run the programme and get information is:
    11022887 insert ok.
    11022887 insert ok.
    11022887 insert ok.
    11022887 insert ok.
    but i use the transation PA30 to view all data:
    in database just exist one row:
    four line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080101' , it_pa9004-endda = '20081031'
              it_pa9004-zzvalue = 80 (customer field).
    the second scenario is:
    in database the infotype have exist one row:
               pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ02',
               pa9004-begda = '20080318' , pa9004-endda = '20080318'
               pa9004-zzvalue = X (customer field).
    and i create another row:
    line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ02',
              it_pa9004-begda = '20080318' , it_pa9004-endda = '99991231'
              it_pa9004-zzvalue = 80 (customer field)
    i run the programme and get information is:
    11022887 insert ok.
    the three scenario is:
        set  HR_INFOTYPE_OPERATION of import parameter operation = 'MOD'
        in any scenario will get error :not exist subtype .
    what heppend about HR_INFOTYPE_OPERATION working,i had to use this function to
       create other infotype of SAP owner.
       and will create successfully.
    so i thank it may be config Constraints about customer infotype.
    is time Constraints effect?
    so i want to how to check it?
    and if i want to create one infotype for customer using PM01 what some thing
    must be taken into account.
    think you advance.
    partial source code as follow:
    FORM ACTION_INSERT .
      DATA: P_FLAG TYPE C.
      DATA: WA_LOG LIKE LINE OF DATA_LOG.
      DATA: PP_ACTION TYPE PSPAR-ACTIO.
      LOOP AT IT_PA9004.
        CLEAR P_FLAG.
        CALL FUNCTION 'HR_PSBUFFER_INITIALIZE'.
        PERFORM lock_employee USING IT_PA9004-pernr CHANGING P_FLAG.
        PP_ACTION = IT_PA9004-ACTION.
        PERFORM HR_INFOTYPE_OPERATION USING IT_PA9004 PP_ACTION CHANGING P_FLAG.
        IF P_FLAG IS INITIAL.
          if test_run = space.
            COMMIT WORK.
          else.
            ROLLBACK WORK.
          endif.
          write:/ it_pa9004-pernr,'insert ok'.
        ELSE.
          ROLLBACK WORK.
          write:/ it_pa9004-pernr,'error'.
        ENDIF.
        PERFORM unlock_employee USING IT_PA9004-pernr .
      ENDLOOP.
    ENDFORM.                    " ACTION_INSERT
    FORM LOCK_EMPLOYEE  USING    P_PERNR
                        CHANGING PP_FLAG.
      CHECK PP_FLAG IS INITIAL.
      CLEAR P_RETURN.
      CALL FUNCTION 'BAPI_EMPLOYEE_ENQUEUE'
        EXPORTING
          number = P_PERNR
        IMPORTING
          return = P_RETURN
        EXCEPTIONS
          OTHERS = 01.
      CALL FUNCTION 'HR_INITIALIZE_BUFFER'
        EXPORTING
          pernr = P_PERNR.
      IF P_RETURN IS NOT INITIAL.
        PP_FLAG = '1'.
      ENDIF.
    ENDFORM.                    " LOCK_EMPLOYEE
    FORM HR_INFOTYPE_OPERATION  USING    P_PA9004 LIKE IT_PA9004
                                         P_ACTION type PSPAR-ACTIO
                                CHANGING PP_FLAG.
      CHECK PP_FLAG  IS INITIAL.
      DATA: bapipakey type bapipakey,
            P_SUBTY TYPE P9004-SUBTY,
            PP_9004 TYPE TABLE OF  P9004 WITH HEADER LINE.
      CLEAR P_RETURN.
      REFRESH PP_9004.
      MOVE-CORRESPONDING P_PA9004 TO PP_9004.
      IF P_ACTION = 'INS'.
        PP_9004-AEDTM = SY-DATUM.
        PP_9004-UNAME = SY-UNAME.
      ENDIF.
      IF P_ACTION = 'MOD'.
        PP_9004-AEDTM = SY-DATUM.
        PP_9004-UNAME = SY-UNAME.
      ENDIF.
      APPEND PP_9004.
      P_SUBTY = P_LGART.
      CALL FUNCTION 'HR_INFOTYPE_OPERATION'
        EXPORTING
          infty         = '9004'
         subtype       = 'FQ03'
          subtype       = P_SUBTY
          number        = PP_9004-pernr
          validityend   = PP_9004-ENDDA
          validitybegin = PP_9004-begda
         RECORDNUMBER  = pp_9004-seqnr
          record        = PP_9004
           operation     = 'INS'
         operation     = P_ACTION
          nocommit      = 'X'
        IMPORTING
          return        = P_RETURN
          key           = bapipakey
        EXCEPTIONS
          OTHERS        = 0.
      IF P_RETURN IS NOT INITIAL.
        PP_FLAG = '9'.
      ENDIF.
    ENDFORM.                    " HR_INFOTYPE_OPERATION
    FORM UNLOCK_EMPLOYEE  USING    P_PERNR.
      CALL FUNCTION 'BAPI_EMPLOYEE_DEQUEUE'
        EXPORTING
          number = p_pernr
        IMPORTING
          return = P_RETURN
        EXCEPTIONS
          OTHERS = 01.
    ENDFORM.                    " UNLOCK_EMPLOYEE

    hi
    i want to create infotype use function(HR_INFOTYPE_OPERATION).
    this infotype is customer infotype.
    the first scenario is:
      i'm be sure no data about one employee in this infotype(9004).
      to call with data upload function and put data into internal table IT_PA9004.
      and the table data as follow:
    one line: it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080201' , it_pa9004-endda = '20080930'
              it_pa9004-zzvalue = 50 (customer field).
    two line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080201' , it_pa9004-endda = '20080930'
              it_pa9004-zzvalue = 60 (customer field).
    three line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080101' , it_pa9004-endda = '20081031'
              it_pa9004-zzvalue = 70 (customer field).
    four line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080101' , it_pa9004-endda = '20081031'
              it_pa9004-zzvalue = 80 (customer field).
    i run the programme and get information is:
    11022887 insert ok.
    11022887 insert ok.
    11022887 insert ok.
    11022887 insert ok.
    but i use the transation PA30 to view all data:
    in database just exist one row:
    four line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ03',
              it_pa9004-begda = '20080101' , it_pa9004-endda = '20081031'
              it_pa9004-zzvalue = 80 (customer field).
    the second scenario is:
    in database the infotype have exist one row:
               pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ02',
               pa9004-begda = '20080318' , pa9004-endda = '20080318'
               pa9004-zzvalue = X (customer field).
    and i create another row:
    line:it_pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ02',
              it_pa9004-begda = '20080318' , it_pa9004-endda = '99991231'
              it_pa9004-zzvalue = 80 (customer field)
    i run the programme and get information is:
    11022887 insert ok.
    but in database just exist the first data
               pa9004-pernr = '11022887' ,it_pa9004-subty = 'FQ02',
               pa9004-begda = '20080318' , pa9004-endda = '20080318'
               pa9004-zzvalue = X (customer field).
    the three scenario is:
        set  HR_INFOTYPE_OPERATION of import parameter operation = 'MOD'
        in any scenario will get error :not exist subtype .
    what heppend about HR_INFOTYPE_OPERATION working,i had to use this function to
       create other infotype of SAP owner.
       and will create successfully.
    so i thank it may be config Constraints about customer infotype.
    is time Constraints effect?
    so i want to how to check it?
    and if i want to create one infotype for customer using PM01 what some thing
    must be taken into account.
    think you advance.
    partial source code as follow:
    FORM ACTION_INSERT .
      DATA: P_FLAG TYPE C.
      DATA: WA_LOG LIKE LINE OF DATA_LOG.
      DATA: PP_ACTION TYPE PSPAR-ACTIO.
      LOOP AT IT_PA9004.
        CLEAR P_FLAG.
        CALL FUNCTION 'HR_PSBUFFER_INITIALIZE'.
        PERFORM lock_employee USING IT_PA9004-pernr CHANGING P_FLAG.
        PP_ACTION = IT_PA9004-ACTION.
        PERFORM HR_INFOTYPE_OPERATION USING IT_PA9004 PP_ACTION CHANGING P_FLAG.
        IF P_FLAG IS INITIAL.
          if test_run = space.
            COMMIT WORK.
          else.
            ROLLBACK WORK.
          endif.
          write:/ it_pa9004-pernr,'insert ok'.
        ELSE.
          ROLLBACK WORK.
          write:/ it_pa9004-pernr,'error'.
        ENDIF.
        PERFORM unlock_employee USING IT_PA9004-pernr .
      ENDLOOP.
    ENDFORM.                    " ACTION_INSERT
    FORM LOCK_EMPLOYEE  USING    P_PERNR
                        CHANGING PP_FLAG.
      CHECK PP_FLAG IS INITIAL.
      CLEAR P_RETURN.
      CALL FUNCTION 'BAPI_EMPLOYEE_ENQUEUE'
        EXPORTING
          number = P_PERNR
        IMPORTING
          return = P_RETURN
        EXCEPTIONS
          OTHERS = 01.
      CALL FUNCTION 'HR_INITIALIZE_BUFFER'
        EXPORTING
          pernr = P_PERNR.
      IF P_RETURN IS NOT INITIAL.
        PP_FLAG = '1'.
      ENDIF.
    ENDFORM.                    " LOCK_EMPLOYEE
    FORM HR_INFOTYPE_OPERATION  USING    P_PA9004 LIKE IT_PA9004
                                         P_ACTION type PSPAR-ACTIO
                                CHANGING PP_FLAG.
      CHECK PP_FLAG  IS INITIAL.
      DATA: bapipakey type bapipakey,
            P_SUBTY TYPE P9004-SUBTY,
            PP_9004 TYPE TABLE OF  P9004 WITH HEADER LINE.
      CLEAR P_RETURN.
      REFRESH PP_9004.
      MOVE-CORRESPONDING P_PA9004 TO PP_9004.
      IF P_ACTION = 'INS'.
        PP_9004-AEDTM = SY-DATUM.
        PP_9004-UNAME = SY-UNAME.
      ENDIF.
      IF P_ACTION = 'MOD'.
        PP_9004-AEDTM = SY-DATUM.
        PP_9004-UNAME = SY-UNAME.
      ENDIF.
      APPEND PP_9004.
      P_SUBTY = P_LGART.
      CALL FUNCTION 'HR_INFOTYPE_OPERATION'
        EXPORTING
          infty         = '9004'
         subtype       = 'FQ03'
          subtype       = P_SUBTY
          number        = PP_9004-pernr
          validityend   = PP_9004-ENDDA
          validitybegin = PP_9004-begda
         RECORDNUMBER  = pp_9004-seqnr
          record        = PP_9004
           operation     = 'INS'
         operation     = P_ACTION
          nocommit      = 'X'
        IMPORTING
          return        = P_RETURN
          key           = bapipakey
        EXCEPTIONS
          OTHERS        = 0.
      IF P_RETURN IS NOT INITIAL.
        PP_FLAG = '9'.
      ENDIF.
    ENDFORM.                    " HR_INFOTYPE_OPERATION
    FORM UNLOCK_EMPLOYEE  USING    P_PERNR.
      CALL FUNCTION 'BAPI_EMPLOYEE_DEQUEUE'
        EXPORTING
          number = p_pernr
        IMPORTING
          return = P_RETURN
        EXCEPTIONS
          OTHERS = 01.
    ENDFORM.                    " UNLOCK_EMPLOYEE

  • How to create the custom infotypes in Campus Management

    Hi,
    Please help me how to create the custom infotypes in campus management.
    Thanks,
    Lakshmi.

    Hi,
    Steps to create a HR Infotype:
    1) Go to Transaction PM01.
    2) Enter the custom Infotype number which you want to create (Should be a 4 digit number, start with 9).
    3) Select the 'Employee Infotype' radio button.
    4) Select the 'PS Structure Infotype'.
    5) Click on Create... A separate table maintenance window appears...
    6) Create a PS structure with all the fields you want on the Infotype
    7) Save and Activate the PS structure
    8) Go back to the initial screen of PM01.
    9) Click on 'All' push button. It takes a few moments.
    10) Click on 'Technical Characteristics'. Infotype list screen appears
    11) Click on 'Change'(pencil) button
    12) Select your Infotype and click on 'Detail' (magnifying glass) button
    13) Give 'T591A' as subtype table
    14) Give 'T591S' as subtype txt tab
    15) Give your subtype field as subtype field
    16) Save and come back to PM01 initial screen
    17) Click on 'Infotype Characteristics' ... Infotype list screen appears
    18) Click on 'Change' (pencil) button
    19) Click on 'New Entries'
    20) Enter your Infotype number and short text
    21) Here we have to set different Infotype Characteristics as per the requirement. (Better open another session with some standard Infotype's infotype characteristics screen and use as the reference to fill yours)
    22) Save your entries.
    23) Now the Infotype is created and ready to use.
    24) If you want to change the layout of the Infotype as per your requirement...
    25) In the PM01 initial screen...Select 'Screen' radio button and give 2000 as the screen name, then click on edit.
    26) In the next screen.. Select 'Layout Editor' and click 'Change'.
    27) Screen default layout appears...here you can design/modify the screen..change the attributes of the fields..etc.
    28) Save and activate. (Don't forget to 'Activate at every level)
    Subtype Creation :
    Transaction PM01 Goto Subtype Characteristics. Click on Append and then subtype. Enter the name and description of subtype on screen.
    Then goto technical Characteristics and maintain the details of subtype there. I.e name of subtype i.e. component name defined in PSnnnn. Subtype table is T591A.
    Subty.text tab is T591S and time const tab is T591A.
    See:
    http://help.sap.com/saphelp_46c/helpdata/en/4f/d5268a575e11d189270000e8322f96/content.htm
    HR related site:
    http://www.sapdevelopment.co.uk/hr/hrhome.htm
    Enhancement of Infotype
    Check the following
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAXX/PYINT_INFOTYP.pdf
    Infotype Enhancement overview screen
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/60a7586d-edd9-2910-68a8-8204303835a1
    Cheers,
    vasavi.
    kindly reward if helpful.

  • Custom Infotype - Using Table control in the screen.  IN OM

    Hi,
    I am having a requriement where in I need to create a custom infotype using table control in the screen. I have to create this in OM and I am using PPCI transaction to create the info type. I am able to create the infotype with fields but not table control. Please let me know if any one of you came across and help me with the process I need to follow.
    Thanks in advance.
    Venkat.

    Hello,
    After you create the info type throug PPCi, you can directly go to the Sceen module program created automatically while creating Info type and edit the screen.
    activate it after your changes.
    Regards,
    Srujan.

  • Data not storing in Custom infotype build with tab strips

    Hi All,
    I have created one custom infotype 9030,
    With screen 2000.
    which is having tab strips, I have build the screens refering to p9030-zztest its not storing in database.
    where I am doing wrong...please let me know what should be done in this case.
    Regards
    Satish.v

    Hi,
    Checkout the below link :
    <link to blacklisted site removed by moderator>
    Shailaja Ainala.
    Edited by: Thomas Zloch on Jan 28, 2012 9:06 PM

  • How to create custom infotype for training and event management

    hai freinds can any one tell me how to create custom infotype for training and event managment with following fields
    PS No – PA0000-> PERNR
    Name   - PA0001 -> ENAME
    IS PS.No. – PA0001-> PS no. of Immediate Superior
    IS name PA0001 -> ENAME
    thanx in advance
    afzal

    Hi,
    Your question is not clear for me. Since it is a TEM infotype, it could be a PD infotype.
    If you wish to create a PD infotype, use transaction PPCI to create the infotype.
    But before that you need to create a structure HRInnnn (where nnnn is the infotype number) with all the fields relevant for the infotype.
    If you wish to create a PA infotype, use transaction PM01 to create the infotype.
    But before that you may be required to create a strcuture PSnnnn  (where nnnn is the infotype number) with all the fields relevant for the infotype.
    Regards,
    Srini

  • Hiding table fields in custom infotype

    HI guyz,
    i have created a custom infotype which has 2 subtypes . certain fields should not be displayed when we select the subtypes. i have used the code below. the screen contains a table.
    MODULE hide_FIELDS OUTPUT.
    IF p9555-subty = '1'.
    LOOP AT SCREEN.
    IF screen-group2 = 'ABC'.
    screen-active = 0.
    MODIFY SCREEN.
    ENDIF.
    ENDLOOP.
    ENDIF.
    IF p9555-subty = '2'.
    LOOP AT SCREEN.
    IF screen-group2 = 'XYZ'.
    screen-active = 0.
    MODIFY SCREEN.
    ENDIF.
    ENDLOOP.
    ENDIF.
    ENDMODULE. " hide_FIELDS OUTPUT
    the fields which are not in the table are not getting displayed as required but the fields in the table still appear on the screen(they are grayed out). i do not want them to appear on the screen. can anyone help me with this. Thanks in advance.

    Hi Madhu Reddy , instead of using screen-invisible = '1' , u can try this .
    MODULE sereen_modify OUTPUT.
    DATA:  COL TYPE CXTAB_COLUMN.
    LOOP AT TC-COLS into COL.      " TC is ur Table Control
      IF col-screen-group1 EQ '007'.     " Modification group1 is say 007.Also u can add other              checks like pnnnn-subty = 1 here .
       col-invisible = '1'.
       col-screen-output = '0'.
       modify TC-COLS from COL index COL-INDEX.
         ENDIF.
    ENDLOOP.
    ENDMODULE.                           " Call this module in ur Flow Loic PBO.
    *Reward Points If Helpful

  • Need to create maintenance view for a custom infotype

    A custom infotype 90XX is created. The data cannot be modified or created through PA30 in this infotype. Through PA 40 actions only we can create/change the record/data. We have created some 1000 records in it. Now can we create a maintenance view for the infotype so that we can create, delete or change the data in the infotype as and when we want.

    Hi,
    pls chk dat u have maintained the 'Infotype Charecteristics' and 'Technical Attributes' correctly.
    thanks,
    teja.

  • Module pool F4-Help problem for a field in custom Infotype(HR).

    Dear Gurus,
    I have created a custom Infotype and fields are like
    P9015-NAM01.
    P9015-NAM02.
    P9015-NAM03.
    all are fields for name.
    I want F4 help for these fields with values same as  Family Members-First name  given in 21 Infotype .
    for all 3 fields same f4 help values.
    But when i see in the screen for first field the values are populating as selected but for second field the selected value is not picking..
    DATA: BEGIN OF it_val1 OCCURS 7,
        nam01 LIKE p9015-nam01,
        rel01 LIKE p9015-rel01,
       END OF it_val1.
      SELECT *  FROM t591s INTO TABLE it_t591s WHERE
         sprsl = 'EN' AND
         infty = '0021'.
    *SUBTY
    *STEXT
      SELECT * FROM pa0021 INTO wa_21 WHERE pernr = p9015-pernr .
        READ TABLE it_t591s WITH KEY subty = wa_21-famsa.
        it_val1-rel01 = it_t591s-stext.
       CONCATENATE wa_21-favor wa_21-fanam INTO it_val-nname SEPARATED BY space.
        it_val1-nam01 = wa_21-favor.
        APPEND it_val1.
        CLEAR : it_val1, it_t591s.
      ENDSELECT.
      CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
        EXPORTING
        DDIC_STRUCTURE         = ' '
          retfield               = 'NAM01'
        PVALKEY                = ' '
         dynpprog               = sy-cprog
         dynpnr                 = sy-dynnr
        dynprofield            = 'P9015-NAM01'
        STEPL                  = 0
        WINDOW_TITLE           =
        VALUE                  = ' '
         value_org              = 'S'
         multiple_choice        = ' '
         display                = 'F'
        CALLBACK_PROGRAM       = ' '
        CALLBACK_FORM          = ' '
        MARK_TAB               =
      IMPORTING
        USER_RESET             =
        TABLES
          value_tab              = it_val1[]
         field_tab              = t_fields[]
         return_tab             = t_return[]
         DYNPFLD_MAPPING        = t_DYNPFLD_MAPPING
      EXCEPTIONS
        PARAMETER_ERROR        = 1
        NO_VALUES_FOUND        = 2
        OTHERS                 = 3
    In the same way i am calling for P9015-NAM02. & P9015-NAM03.
    Is there any wrong in calling this FM...kindly help.....

    Write the FM inside,
    at selection-screen on value-request for <nam1>.
    It seems that you are calling the funtion module for only first field. Repeat it for other two fields also-
    at selection-screen on value-request for <nam2>
    call FM.
    at selection-screen on value-request for <nam3>
    call FM.
    Sumit

Maybe you are looking for

  • How to select from a stored procedure?

    Lets say I have a simple stored procedures Create Procedure stp_test As Begin  Select * from tbl1 End Go I would like to be able to do this in SSMS (actually, I want to do this from ADODB) Select top 10 * from ...stp_test... Order By rowID It looks l

  • Apple Moblie Device service is not started - Cannot be started.

    Running Windows 7 64bit and iTunes 10.1.0.54 I've been able to sync my iPod in the past. Now, when I plug it in, I get the message "This iPod cannot be used because the Apple Moblie Device service is not started." Ok, so I try to start the Apple mobi

  • 9.2 wont upgrade library

    I get this message everytime I open I photo The photo library needs to be upgraded to work with this version of iPhoto. I click upgrade and it wont do anything

  • How do I switch to one of my other backups?

    How do I switch to one of my other backups?

  • How to relink files inside an avchd package ?

    I messed up a library and lost a project, then I found a copy of it in the backup folder, now when I open the project it asked me to relink files, but a part of them are inside an avchd package. How to relink those files ? Thanks