Customizing-IMG-structure cross docking not visible

The customizing-IMG-structure "cross docking" is not visible / available within SAP ECC 6.0-system altough WM-module is used. It is visible via SIMGH but can not be used / displayed via SPRO.
Could you please tell me what is the reason for this?
In addition the cross-docking transactions can not be executed (e.g. lxdck ; "You are not authorized to monitor XDOCK").

Hi
Please check the following thread.
Cross-Docking functionality in ECC 6.0
Thanks
Anandha

Similar Messages

  • Opportunistic cross-docking not working

    Hi All,
    We are trying to implement opportunistic cross-docking process. My understanding is that during the creation of the goods receipt TO the system looks for any open picking TO and accordingly directly moves material from 902 to 916 storage type. The following configuration is done
    1. For the warehouse opportunistic cross-docking has been activating by selecting option 4.
    2. Cross-docking relevancy has been defined for movement type 101
    3. For movement type 101, the 'Consider pre-allocated' check box is not ticked
    4. In the respective movement types 1 & 2 for 'TO creation' are entered as screen control in movement types 101 and 601
    5. No automatic confirmation for TO is set up
    The following transactions are now done
    1. Create a sales order with outbound delivery and TO created (not confirmed)
    2. PO with MIGO (we are not using HU and hence no inbound delivery)
    3. Now during the creation of the TO for the goods receipt, the expectation is that the system will look for the open picking TO and will cancel the same and then create the putaway TO directly from 902 to 916. But this does not happen.
    Not sure if I am missing some setting or some transaction needs to be done differently. I went through SAP help but it does not give more details on what setting might be missing.
    Regards,
    Ketan

    Hi Jurgen,
    Thanks for the link. But I had already gone through it and configured the system accordngly. The surprising part is that corss-docking is working for outboud documents i.e. if i create a TO for inbound first and then for outbound then while creating the TO for outbound it automatically takes the source as 902 and cancels the put away TO. However for other way round where the outbound TO is first created and then the inbound, the expectation is that reverse should happen i.e. the destination in the TO should be taken as 916 and original picking TO should be cancelled. However it is not happening.
    In the link it talks about points 5 & 6 which are only for HU environment and since we do not have the same I have not configured those. But my question now would be is it that opportunistic inbound cross-docking can only be possible with HU but not required for outbound. Else I do not see any other reason why this might be happening.

  • Cross References Not Visible in Panel

    Hi all,
    I have been enjoying the Cross References functionality in Indesign CS6 to use dynamic text that changes....until recently.
    When i first started using them, the Cross References (CR) would be listed in the Hyperlinks/CR panel.
    I can create a destination, create a hyperlink to that destination, change what it shows (I am using Paragraph Number) and it works as it should.
    The problem i am having is that the CRs are not visible in the Cross Reference panel (the hyperlinks too for that matter)
    This means i cant modify my cross references.
    Does anyone know why they wouldnt show in the panel? Or is there any other way to see them?
    I need to fix this. I have tried resetting the preferences as i found in other posts, but that didnt help

    SOLVED!
    The problem appeared to be with my Workspace profile. I changed from my personalised profile to "Interactive for PDF" ( which has the Hyperlinks panel) and it worked. All the Hyperlinks and cross-references show.
    I personalised my workspace again with the panels i require and then saved a new workspace with the same name. All works fine after saving a new profile. I am going to take a backup of the workspace file so i can restore it easily if it happens again.

  • Custom properties added by EWS not visible in Outlook

    Hi all
    I'm a first-time Exchange and Outlook addin developer and I'm stuck on a problem.
    I'm working on a project where we use an Outlook 2003 addin that tags items; mail, appointments and tasks
    with custom properties.
    In Outlook we do this by adding the data as UserProperties.
    After the items have been saved an onsave eventSink triggers on the Exchange 2007 mailbox server and using CDOEX, checks for the tags, collects some data and sends them to an web service wich stores the data on an AX server.
    This works fine.
    Then we want the AX server to be able to update and create new items back against exchange, and for this we use Exchange Web Services.
    I've made an application that performs the operations agains EWS, and everything works smoothly except when we add the custom properties.
    We add them as extendedproperties with the following code:
    ExtendedPropertyType extendedProperty = new ExtendedPropertyType();
    extendedProperty.ExtendedFieldURI = new PathToExtendedFieldType();
    extendedProperty.ExtendedFieldURI.DistinguishedPropertySetId = DistinguishedPropertySetType.PublicStrings;
    extendedProperty.ExtendedFieldURI.DistinguishedPropertySetIdSpecified = true;
    extendedProperty.ExtendedFieldURI.PropertyName = propertyName;
    extendedProperty.ExtendedFieldURI.PropertyType = MapiPropertyTypeType.String;
    extendedProperty.Item = propertyValue;
    This worked well for the eventSink, we found the fields and got the values just like we did for items tagged by the Outlook addin.
    However, the Outlook Addin could not find them in the UserProperties object for the item, and Using Outlookspy I could plainly see that they were not present.
    After a bunch of searching I found a thread on this forum that discussed adding custom properties as ExtendedPropertyTypes via EWS using a guid as a PropertySetType.
    Here it is: http://forums.microsoft.com/technet/showpost.aspx?postid=1764780&siteid=17
    I followed the instructions here, and now both the eventSink and Outlook are unable to find the properties.
    My question is:
    How can I apply my tags so both my Outlook addin and EWS can create, update and read them, as well as allowing the eventSink to easily read them?
    The simplest way, I imagine, is if I could make Exchange Web Services place the properties in the "UserProperties" object.
    I would greatly appreciate any help.
    thanks
    Ragnar Fatland

    I first created an extended property:
    ExtendedPropertyDefinitionepdGuid =
    newExtendedPropertyDefinition(
    DefaultExtendedPropertySet.PublicStrings,
    "Guid",
    MapiPropertyType.String);
    Then I setup the service:
    ExchangeServiceservice =
    newExchangeService(ExchangeVersion.Exchange2010_SP2);
    Find all the items:
    FindItemsResults<Item>
    userItems = service.FindItems(newFolderId(WellKnownFolderName.Inbox,
    userMailbox),
    newItemView(int.MaxValue,
    0)
            PropertySet =
    newPropertySet(BasePropertySet.FirstClassProperties,
    epdGuid)
    Loop through the userItems:
    foreach(varitem
    inuserItems)
    if(item
    isEmailMessage)
    EmailMessagemessage = item
    asEmailMessage;
    Do a message load with the PropertySet (if you don't do the PropertySet you won't see any extended properties):
    message.Load(
    newPropertySet(epdGuid));
    Then you can loop through the extended properties:
    foreach(varextendedProperty
    inmessage.ExtendedProperties)
    if(extendedProperty.PropertyDefinition.Name
    == "Guid")

  • Custom FPM application: why is not visible when creating iview?

    hi,
    I am trying to modify an exiting mss application which is a fpm application.
    i use the self service admin tool to copy the standard fpm application to a deltalink, and ,according to the documentation , next step should be creating an iview (webdynpro iview), and the delta link should be visible as an application variant ,but it's not there.
    i tried many times and option ,but failed.
    does anyone know what's going wrong?
    another question is , if i build a new fpm application using the given tool, can it be visible when i create the iview? under which webdynpro component? i can only see com.sap...
    br.
    zj

    Hi,
    I've the same problem, after copy the FPM application as delta linkit doesn't appear as  anew app_variant when I create a new iview.
    Does anybody know why this occurs?
    Thanks!
    Pablo.

  • I can't add an event to an event structure. Option not visible in the menu. Fix?

    I didn't have the event structures on my pallette to begin with (LabVIEW 6.1), so I added them by downloading the struct.mnu file on the website. Now they show up in the pallette, but are not usable because I can't add events. Any help would be much appreciated.

    You're correct, if you have the Full version, you should be able to create and edit the Event Structure. The Base version is the only one that is limited.
    I would try the reinstall and see if that takes care of it. Something must have gotten corrupted.
    Ed
    Ed Dickens - Certified LabVIEW Architect - DISTek Integration, Inc. - NI Certified Alliance Partner
    Using the Abort button to stop your VI is like using a tree to stop your car. It works, but there may be consequences.

  • Cross Docking Functionality - ECC6.0

    Hi,
    Can some explain in detail what are the Cross Docking Functionalities has been provided in ECC 6.0 compared to the previous versions.
    Thanks,
    Chak.

    Hi chakku,
    Cross docking changes in ECC 6.0.
    Effects on Customizing
      To use Cross-Docking, you must define the following in Customizing for
      Logistics Execution -> Warehouse Management - Cross-Docking:
      o   General warehouse level settings, including the cross-docking
          storage type, outbound document release and latest release times,
          and FIFO tolerance duration.
      o   The relevancy of cross-docking for warehouse movement types
      You also have the option of personalizing the monitor and alert monitor,
      as well as implementing project-specific logic via Business Add-Ins.
    See also
      o   IMG for Logistics Execution -> Warehouse Management -> Cross-Docking
      o   SAP Library for Logistics Execution -> Warehouse Management ->
          Cross-Docking
    Regards,
    hareesha

  • Credit control field not visible in customer master after checking Spro

    Hello Gurus,
    I have configured Automatic Credit Control In IMG.
    I have checked all the necessary spets required for the avtivation of Automatic Credit Control.
    But I am facing in problem and will appreciate all your help for this problem.
    In Customer master> Sales area data> Billing Document--> delivery and payment terms. Within delivery and payment terms the feild for credit control area is not visible.
    I have checked in spro>financial accounting> Ac rec & Ac payable>customer account>master data>preparation for creating customer master> define account groups with screen laypouts (customers).
    Within Define account groups with screen laypouts (customers)>account group 001(soldtoparty)details>field status>sales data>billing-->Hedging and credit contr. area I have tried it with optional as well as reuired entry and still the credit control field is not visible in customer master.
    Pls provide me the steps as well as solutions for the problem.
    Thanks & regards,
    Dev.

    pls check accunt group again
    rgds
    nitin

  • Need Help: Workflow Decision Task not visible in NWBC for customer Task

    Hello All,
    I am  new to NWBC configuration , need ur expert knowledge  for the below issue. I have checked the treat . Approve/Reject button for SRM Approval for RFx response ,but not able to get the exact steps for the configurations in NWBC.
    Requirement.
         We are working on SLM/SRM module, where we have requirement to create a custom workflow with custom Task for which we have executed below actions.
    Created the Custom Workflow.
    Created the custom Task with custom  ZCLASS and ZEVET.
    Created   Event linkages in SWE2.
    After doing this we are getting the workitem in the NWBC, currently we don’t have the Portal system in place, so we are using the NWBC for all our testing.
    What is the issue?
         When we select the workitem in the NWBC (UML) inbox  , the Decision Task ie “Approve” or “Reject” button are not visible , where as for SAP standard  Task  buttons are visible.
    What help we need?
      When we cross check the SCN/IBM portal, found that we need to do the XML file configurations. Can you any one kindly let us know the steps we need to follow to achieve our functionality.
    Thanks a lot in advance.
    Thanks and Regards
    Channa

    You need to share the details of what Inbox you are using, configuration steps depend on it. If you aren't using portal, you aren't using UWL and there is no UML inbox. You need to get your facts straight. Most likely you are using the Business Workflow Inbox (SWF_WORKPLACE) or the Lean Inbox (IBO_WDA_INBOX). Both are based on Web Dynpro ABAP and POWL but the configuration is different. Regardless, you posted this in the wrong space. Correct space is either SAP NetWeaver Business Client or Web Dynpro ABAP.

  • Cross docking - planning not possible

    I have set the customizing settings (maintain warehouse level settings ; defince cross-docking relevancy for movement type 101 and 350 ; maintain number rangers) for cross docking but I am still not able to link an inbound TR to a outound TR (same quantity / material).
    The error messages "No matching inbound documents found" occurs when I try to "Plan the cross-docking".
    Scenario
    outbound TR for KANBAN WM replenishement (mvt 350)
    inbound TR for goods receipt posting (mvt 101)
    Thank you in advance!

    Hello,
    Can anyone reply this?
    I don´t have a solution yet.
    Thanks a lot,
    Jesus

  • Custom field not visible for Project task in PPM 5.0

    Hi,
    I have done the SPRO configuration required to add a custom field in Project task
    1. Enhance DB table. added  the field in structure DPR_TS_TASK_EXTENDED_ATTR, object type TTO
    2. Define field groups for custom fields
    3. Set up field control.
    The custom field tab has come after making SPRO changes. But the field is not visible on the tab.
    Please let me know if I am missing any steps.
    Thanks,
    Yomesh

    Dear Yomesh;
    You have to config the view or subview at:
    SAP Portfolio and Project Management -> Portfolio Management -> Global Customizing -> Global Field Settings -> Assign Fields to Views/Subviews
    Here try to to setup the view that you want to see the custom field.
    Hope you help you.
    Regards.
    Mariano

  • Roadmap structure not visible - Urgent help pls...

    Hello All,
    I tried creating a custom roadmap with my own folder structure. I created it as all subfolders.
    Once I am done with creation, I tried with RMMAIN transaction to view the same. But unfortunately I am not able to see the structure created by me.
    I am sure that I am missing something with the 'Entry Screen' button of the RMAUTH transaction. But not able to figure out what it is. When I press the 'Entry Screeen' button, I am able to see all the folders I created for my Roadmap structure.
    But the same is not visible in RMMAIN. Can anybody help me figuring out what I am missing and where I am missing?
    Any input in this regard will be greatly appreciated. Thanks a lot in advance.
    best regds,
    Alagammai.

    Without having to go into a lot of details on this - there are ample details on how to use these objects together to create a custom road-map.  There can be a number of things wrong that are not being satisfied by the work you have done so far.  You can access the guide in the http://service.sap.com/solutionmanager -> media library -> documentation -> 4.0 SP12 File.  Goto the section on Creating RoadMaps - it can explain all the nuances better than I can.  Personally I think that there is an issue with the flavor and how you have assigned your components such that when you created your project - there was nothing to display but go through the guide anyhow and see what might be the issue.
    Remeber that you can always copy a RoadMap and then remove a bunch of stuff that you don't like - this is the typical method of doing business that I have seen that works pretty well.  Making these from scratch can be a bit of a pain.

  • About Me link is not visible in Welcome Menu if placed on custom location in Custom Master Page

    Experts,
    I am facing a problem in my -ongoing SP 2013 project's branding. The problem is with Welcome Menu. I need to put the welcome menu at a custom place rather than in ribbon area. for this I added welcome menu snippet inside my Master Page HTML but there is
    a problem with it. On ribbon link "About Me" is visible while at the same time link "About me" is not visible on welcome menu which has been inserted on custom place. below images describe my problem more accurately.
    I need help in this regard if some one can help me. For your information My User Profiles are properly configured and working. 
    HBkhan

    Hi Haris,
    I tested the same scenario in my environment, and the link will display My Settings link instead of About Me link when there is more than one welcome menu in the page.
    If you want to put the welcome menu at a custom place rather than in ribbon area, I recommend you remove the welcome menu in the ribbon area(suitebar) after putting the other welcome menu at the custom place.
    Thanks,
    Victoria
    Forum Support
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact
    [email protected]
    Victoria Xia
    TechNet Community Support

  • Custom fields not visible in the Active Subject Area column

    Hello,
    I have created several custom fields in the Object Service Request. I need to create a report with those fields, but some of them are not visible / displayed.
    Is there any delay between the custom field creation and its availability in Oracle Answer? Because, only the "old" custom fields appears in the list.
    Thanks in advance for your advices.
    Laurent

    it generally takes one day to appear in analytics

  • Customized fields Not visible in GUI but visible in PCUI why

    Hi,
      Can anybody help me, i have a problem which is as followes,
    I Enhanced Three fields for Campign in CRM Throw EEWB, these three fields are not appearing in GUI but its appearing in PCUI. 
    Can some body can give me  valueble inputs to solve this issue.
    Thanks & Regards,
    Sivakumar.

    Hi Suyash
    In the TS, on the right side, see if these fields are part of the DS.
    If yes, then click on them and drop them on the left, in the Transfer structure.
    If they are not availabel in the Datasource, then go to RSA6 in R/3 and see if the extract structure of this DS has these fields hidden, i.e if theres a check mark on hide coloumn....
    If these fields are not visible in the extract structure then let me know
    Regards
    Prakash
    Assigning points on SDN is a way of saying thanks !!

Maybe you are looking for

  • 4100n printer is no longer recognized by my laptop when i plug it in

    I have an HP 4100n black ink printer and it has stopped working for no apparent reason. When I plug it in to my laptop it will not recognise the USB device. I have not changed the drivers at all. My laptop's OS is Vista.  I have tried reloading the d

  • Why can't i print a 7x5 picture?

    im having trouble printing a 7x5 it gives me the option of 8x5 instead

  • Audit Reports not being generated

    OIM is not processing any audit reports. ERROR [XELLERATE.AUDITOR] Error while processing audit message java.lang.NullPointerException It didn't process any records till now. The AUD_JMS table has thousands of records. My version: 9.1.0.1865.28 Any s

  • Wireless signal booster

    We have bt infinity and good network coverage in the home. Recently we converted the garage and cannot pick up the signal from that room. This is now my sons bedroom and he has an Xbox and iPad which he normally uses wirelessly but now cannot. Is the

  • How to parse out primitives out of a stream?

    Hi there! I need to parse a lot primitives (chars, ints, longs, bytes) out of a stream. My Problem is, that the following way is very slow: BufferedReader.readline -> String.substring -> Integer.parseInt(String). This algoryth produces a lot of Garba