Dashboard Downtime - Uptime SCOM 2012

Hello
I have SCOM 2012 installed. The principal functions it is able to monitor the uptime and downtime of Windows 2012 R2 servers (Exchange - Lync - Hyper-V) on a Dashboard and have SLA in Datacenter Monitor.
Is possible may have a Dashboard with real-time measurements (Downtime - Uptime) in SCOM and also SLO Dashboard?
I create a SLA Tracking and shutdown a host for 2 hours was always 100% the Dashboard.
Thanks for your help.
Regards

Hi,
When you are creating Service level tracking, please chose Windows operating system as the targeted class, and then create a service level dashboard to add the created SLA, you may get the downtime and uptime information.
The articles below should be helpful for you:
Defining a Service Level Objective Against a Group
https://technet.microsoft.com/en-us/library/hh212877.aspx
SCOM 2012 - Configuring the Service Level Dashboards
http://kevingreeneitblog.blogspot.com/2012/04/scom-2012-service-level-dashboards.html
Regards,
Yan Li
Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

Similar Messages

  • Dashboards Problem after SCOM 2012 Inplace Upgrade- Missing Stored Procedures

    Dears,<o:p></o:p>
    After finishing SCOM 2012 in place Upgrade I face a problem on Performance and Service level dashboards, the Upgrade has been finished successfully as shown below
    But after I start Dashboards configuration I receive below errors
    After troubleshooting I see an error in Event viewer beside the errors on Snapshots above said that
    Fault Detail is equal to could not find stored procedure
    so I compared Stored Procedures under SCOM data warehouse database with another SCOM 2012 installation (different customer) and i see a lot of Missing Stored Procedures
    (all Stored Procedures  start with 'SDK.Microsoft_SystemCenter_Visualization are missing)
    Here i am stuck, I don’t know what I can do, I have some ideas but i don't know if its will work.<o:p></o:p>
    My ideas are:<o:p></o:p>
    1. Repair SCOM 2012 Installation (does the repair option will repair the databases)
    2. Re import Default SCOM Management packs like (Microsoft.SystemCenter.Visualization.Library.mpb) (does MP contains Stored procedures in the Database)<o:p></o:p>
    3. Install Rollup Update (may during installation it will create missing Stored Procedures)
    4. Move Stored Procedures from other SCOM server installation
    Please advise its strange issue
    Appreciate Your help
    Note:<o:p></o:p>
    Everything is work correctly regarding Raising alerts , generate reports , servers state , reset and recalculate health state, installing and ininstalling agents and others.

    Hi,
    Could you post the error message in forum directly? This snapshot it too fuzzy to know what the exactly meaning is.
    Alex Zhao
    TechNet Community Support

  • Unable to add a performance widget to a dashboard in SCOM 2012

    When trying to select a group or object when attempting to configure a new performance widget within a SCOM 2012 dashboard, I get the following error. Anybody any ideas what is causing this issue in my instance of SCOM 2012?
    This is part of a custom built Management Pack and a Distributed Application linking just three computers together.
    Any help would be welcomed.
    Please provide the following information to the support engineer if you have to contact Microsoft Help and Support :
    Microsoft.EnterpriseManagement.Presentation.DataAccess.DataAccessDataNotFoundException: Exception reading objects ---> Microsoft.EnterpriseManagement.Common.UnknownDatabaseException: The query processor ran out of internal resources and could not produce
    a query plan. This is a rare event and only expected for extremely complex queries or queries that reference a very large number of tables or partitions. Please simplify the query. If you believe you have received this message in error, contact Customer Support
    Services for more information.
       at Microsoft.EnterpriseManagement.Common.Internal.ServiceProxy.HandleFault(String methodName, Message message)
       at Microsoft.EnterpriseManagement.Common.Internal.EntityObjectsServiceProxy.GetManagedEntitiesByManagedEntityTypesAndCriteriaWithInstanceQueryOptions(IList`1 managedEntityTypeIds, IList`1 managedEntityBaseTypeIds, IList`1 criterias, String languageCode,
    InstanceQueryOptions instanceQueryOptions)
       at Microsoft.EnterpriseManagement.InstancesManagement.GetObjectsReaderInternal[T](ICollection`1 criteriaCollection, ObjectQueryOptions queryOptions)
       at Microsoft.EnterpriseManagement.Management.DataProviders.ManagedEntityProvider.GetManagedEntitiesByClass(ICollection`1 baseTypeNames, String criteriaString, List`1 valueDefinitions, List`1 sortValueDefinitions, Int32 maxEntities, String typePropertyName,
    String typeWithIconPropertyName, Boolean propertyCollectionRequested)
       --- End of inner exception stack trace ---
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.DataProviderCommandMethodInvoker.Invoke()
       at Microsoft.EnterpriseManagement.Monitoring.DataProviders.RetryCommandExecutionStrategy.Invoke(IDataProviderCommandMethodInvoker invoker)
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.DataProviderCommandMethod.Invoke(CoreDataGateway gateWay, DataCommand command)
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.CoreDataGateway.ExecuteInternal[TResult](DataCommand command)
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.CoreDataGateway.<ExecuteAsync>b__0[TResult](<>f__AnonymousType0`1 data)

    What is your SCOM version and patch level?
    For SCOM 2012 SP1, there is known issue that:
    When you select objects on the dashboard, you receive the following error message:
    Microsoft.EnterpriseManagement.Presentation.DataAccess.DataAccessDataNotFoundException: Exception reading objects ---> Microsoft.EnterpriseManagement.Common.UnknownDatabaseException: The query processor ran out of internal resources and could not produce
    a query plan. This is a rare event and only expected for extremely complex queries or queries that reference a very large number of tables or partitions.
    This can be resolved by apply UR4
    https://support.microsoft.com/en-us/kb/2879276/
    Roger

  • Creat a Dashboard - A Particular User/User Group mails send/receive Statstics - is it possible ? How ? Exchagen 2013 Scom 2012 R2

    I want to see a particular user mailbox statistics for its send receive count in particular hours of the day
    Is there a way to build such a dashboard in SCOM 2012 R2 for Exchange 2013 ?
    Please help.
     

    Hi,
    The follwing article may be helpful
    Monitoring Exchange 2013 with SCOM 2012
    http://www.msexchange.org/articles-tutorials/exchange-server-2013/monitoring-operations/monitoring-exchange-2013-scom-2012-part1.html
    Note: Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SCOM 2012 Service Level Dashboard

    I have been tasked with creating a Service level dashboard for SCOM 2012. After reading up on various blogs and sites around methods and BI / reporting tools I am no closer to knowing what would be the best solution, and would appreciate some guidance.
    I want to create SLO groups for applications - Exchange, AD, SQL, SCCM etc. and have a high level heat map with measures like CPU util, Disk space %, latency etc. updated every minute and displayed in each block (preferably using corners of a single block),
    and if possible to add a bootstrap style icon into each block.
    I would like drill down functionality on each group that then breaks down into another heatmap (per server).
    And then to drill down further which displays a SLD type dashboard on that instance.
    I am comfortable with creating the final level SLD using widgets, would it be possible to use Visio for the heatmaps ?
    I have looked into using Power View, would conditional formatting be a better option ? 
    Id like to publish the dashboard into Sharepoint.
    Would appreciate your feedback. Once i know which solution to look into, it would become much easier to focus my attention.

    Hi,
    I would like to suggest you refer to the articles below:
    Creating a Service Level Dashboard
    http://technet.microsoft.com/en-us/library/hh212692.aspx
    Monitoring Service Level Objectives by Using Operations Manager
    http://technet.microsoft.com/en-us/library/hh212753.aspx
    For more information on the Visio 2010, Sharepoint 2010 and Savision LiveMaps
    solutions, see the excellent blog series by SCOM MVP Marnix Wolf from the link
    below:
    http://thoughtsonopsmgr.blogspot.com/2010/09/scom-and-dashboards.html
    Regards,
    Yan Li
    Regards, Yan Li

  • SCOM 2012 Open Custom Dashboard directly in Console

    I wanted to display a dashboard on a big Screen .
    I was looking for options and with the help i could find , we could open it using Web console on the TV , or Sharepoint Site or Visio diagram
    then i found we could open the particular view directly using SCOM console (If it is installed)
    Using something like: Microsoft.MOM.UI.Console.exe /ViewName:View_f0e6e6d99131451985140cb5f020028e.
    This is valid for SCOM 2007 R2
    Is there an similar option for SCOM 2012, I want to to show a particular dashboard that we created using this method.
    I am following this article
    http://www.peppercrew.nl/index.php/2011/04/scom-open-view-direct-in-console/

    I tried this $mg.GetMonitoringViews() | where {$_.displayname -like "*My Distributed
    App*" | select Name 
    However i am not able to fetch the Distributed Application view that i created.
    Is distributed application different from View. I somehow aint able to find it when using the Powershell or SQL 
    I even tried to fetch from SQl Database as well  using http://www.peppercrew.nl/index.php/2011/04/scom-open-view-direct-in-console/

  • SCOM 2012 - SCOM Dashboard

    Hi all,
    I have SCOM 2012 installed and created some dashboards.
    Our sharepoint server is managed by other department, so it is impossible to install visio extensions or scom console on it.
    Is it possible to create a SCOM dashboard on SCOM server and just reflect it on a Sharepoint page without any single configuraiton on Sharepoint server?
    Thanks.

    No I think You are required little configuration in SP site as well to integrate scom with sp.
    please refer follow link:
    http://social.technet.microsoft.com/Forums/systemcenter/en-US/47cdb930-a586-49ef-a3d9-b94084af8ff0/scom-2012-scom-dashboard?forum=operationsmanagergeneral
    Yes You can create normal dashboard views in SCOM

  • Dashboard View SCOM 2012 R2

    I have 3 views in Monitoring (2 Alert views and 1 State view) that would be nice to combine as one Dashboard view.
    How do I do this in 2012 R2?
    Thx
    John Bradshaw

    Hi Bradje,
    Hope it helps:
    http://www.systemcentercentral.com/creating-opsmgr-2007-r2-style-dashboard-views-in-opsmgr-2012-scom-sysctr/
    Natalya

  • No Data In SCOM 2012 R2 VM Dashboards

    We just applied CU3 for SCOM 2012 R2. We also imported the management packs for the new SCVMM Dashboards. How long should it take before we get data displayed in these new dashboards, 'Virtual Machine Dashboard' and 'VMM Host Dashboard' ?
    Orange County District Attorney

    Hi,
    Based on my understanding, your issue is that you have import SCVMM management pack, under Monitoring workspace on Operation console, under the management pack, you cannot see data under the two dashboard.
    It is suggested to make sure those objects are discovered already, and then check whether those corresponding rules are enabled.
    And it is alway recommended to look into the management pack guide before using it.
    Regards,
    Yan Li
    Regards, Yan Li

  • SCOM 2012 SP1 RU2 Some Dashboard templates are missing

    Hi Everybody,
    I have SCOM 2012 SP1 RU2, (Update Rollup 2 for Microsoft System Center 2012 SP1 - Operations Manager Server (KB2826664)) but I don't see all the Dashboard templates, I just
    see the basic templates.
    I tried to do what the
    article suggests (Applying KB282664 this is for SCOM 2012 SP1):
    http://blogs.catapultsystems.com/cfuller/archive/2014/04/24/operations-manager-2012-r2-ur2-has-a-great-surprise.aspx
    But the template does not appear yet.
    Any Advice?

    Templates are missing when creating a new dashboard view from the Dashboard and Widget Wizard, This issue fixed in UR4 for System Center 2012 SP1
    http://blogs.technet.com/b/momteam/archive/2013/12/10/support-tip-opsmgr-2012-console-issues-fixed-in-update-rollup-4-for-system-center-2012-service-pack-1.aspx
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • SCOM 2012 SP1 availability report in MS Generic Report Libary shows inaccurate data

    Hi,
    in SCOM 2012 sp1, we have the generic availability report showing many of our web sites with no up time beyond a certain date.   The web sites are ok,  the web availability monitors are all healthy and the monitors test ok
    None of these web availability tests are in Maintenance mode although what we are observing certainly makes us think that they are.
    We also have a Web transaction login monitor for WEBSITE(A)  that does not show this same outage for a login test.
    However WEBSITE(A)'s availability monitor shows the same downtime as the other web availability tests.
    Any thoughts on where to look for this problem?  Im guessing its a problem placing the data in the Warehouse?
    Thanks Lance

    Hi,
    Based on my understanding, the report shows there is downtime for the web site, but the web site did work well always.
    It seems like that there is old data stored in data warehouse, would you please check the report for recent date, such as one day or two days.
    Regards,
    Yan Li
    Regards, Yan Li

  • Can overrides from SCOM 2007 R2 be used in a new SCOM 2012 R2 installation?

    Hi All,
    I'm wondering if we can "easily" use our overrides/configuration from our current SCOM 2007 R2 implementation and use them in a new SCOM
    2012 R2 environment that we plan on standing up.  We are using SCOM to monitor approx. 400 servers (physical and virtual).
    We have been using 2007 R2 for a few years and we'd like to start using 2012 R2.  Instead of using the update path (2007 R2 to 2012
    to 2012 SP1 to 2012 R2), we are planning on setting up a new 2012 R2 environment and configuring our servers to start reporting to 2012 R2 (after it has been configured in such a way as to "mimic" our 2007 R2 environment).
    Ideally, we'd like to avoid going through the upgrade path.  (We'll leave our 2007 R2 environment running so that we can still access "historical
    data" until the new 2012 R2 environment has had a chance to build up its own "historical data".)
    So ... I was thinking we could export our overrides from 2007 R2 and import them into 2012 R2, but I'd like to verify that this approach makes
    sense.  We haven't done extensive customizations to 2007 R2 in terms of Distributed Applications or Management Pack Objects (although we have made some changes - which I guess we could manually configure in 2012 R2 to offer the same "experience").
    The following are some of the Management Packs that we are using in 2007 R2:
    Microsoft Windows Active Directory
    Active Directory Certificate Services
    EMC Storage Monitoring
    IBM Hardware
    Microsoft Exchange Server 2010
    McAfee
    Microsoft Forefront Server Protection 2010
    Microsoft Office SharePoint Server 2007
    Microsoft SQL Server
    Microsoft Windows DNS Server
    Microsoft Windows WINS
    Microsoft Windows Hyper-V
    Microsoft Windows Internet Information Services
     Microsoft Windows Server
    Microsoft Windows DHCP
    NetBackup Operations Manager
    Office Communications Server
    OpsLogix (BlackBerry)
    Service Level Dashboard for OpsMgr 2007 R2
    SolarWinds Orion
    Schedule Maintenance Mode
    Team Foundation Server 2010
    Virtual Machine Manager
    Microsoft Windows Cluster
    Operations Manager 2007 R2
    I appreciate all feedback and the sharing of you expertise.
    Thanks, Joe.

    As long as the base pack works and you wish to retain the customisation then you should be ok, there’s a good article
    here which explains how to perform the migration and some of implication/things to check.
    There will be complications if you’ve stored anything in the default mp but this is explained in the above article.

  • SCOM 2012 RC - SCVMM 2012 RC - Virtual machine manager management group is not getting monitored

    Hi All,
      I have integrated SCOM 2012 with SCVMM 2012 environment. I could see two strange behaviors. All these instance are running on Windows 2008 R2 + Sp1 OS along with SQL 2008 R2 for database.
    1) I could see two instance of VirtualmanagerDB
    in the Database State view under the Microsoft SQL Server, out of that
    one is showing as monitored and another one is
    showing as not monitored. Why it is showing two instance of the same database? How can I remove the not monitored one?
    2) In the distributed apps- Virtual machine manager management group is not showing as a monitored item. However the SCVMM server is getting monitored.
    I'd appreciate if someone could help me out in understanding and resolving this.
    Regards,
    Ren.

    Hi
    I opened up a connect ticket on this on 17th Jan so sorry for not noticing your post earlier. The response was:
    Health State dashboard view is targeted to two state views. "Agent Watcher State" and "Agent State". "Agent State" view (view with duplicate entry) is targeted to an abstract class "VMM Agent" which has below child classes.
        VMM Library Agent
        VMM Host Agent
        Guest Agent
    For the Dashboard view, we need to taget the view to "Host Agent" not "VMM Agent". When we install VMM, it adds itself as a Library server and that is the reason for duplicate entry (VMM Library Agent).
    Cheers
    Graham
    Regards Graham New System Center 2012 Blog! -
    http://www.systemcentersolutions.co.uk
    View OpsMgr tips and tricks at
    http://systemcentersolutions.wordpress.com/

  • Monitor Dell Powerconnect Switches/Routers using SCOM 2012

    Hello,
    We are trying to find a way to monitor approximately 20-25 Dell Powerconnect switches/routers (models 5324,5424,5448,5548,6224,6024) through SCOM 2012.
    Using SCOM network discovery we are able to get all Dell Powerconnect switches listed, but we are unable to get a network node dashboard, nor vicinity view 1 or 2 hops further. We are able to only see connected network printers and some serial/ethernet devices
    we have.
    In addition, SCOM 2012 seems to be able to recognize the model of only Dell Powerconnect 5224 switches. We have found that on the SCOM management server the "C:\Program Files\System Center 2012\Operations Manager\Server\NetworkMonitoring\conf\discovery\oid2type_Dell.conf"
    only lists Dell Powerconnect 5224 switches as well as several models from the 3000 series.
    We have contacted Dell PRO support, but their reply was that there is no management pack for SCOM available for their networking devices.
    Would it be recommended to use http://xsnmp.codeplex.com/ on SCOM 2012 to monitor those switches and get a network digram view or are there any plans to include those MIBs in a future CU or SP of SCOM 2012? 

    Hi Alex
    Network monitoring has changed from SCOM 2007 R2 to SCOM 2012 so this statement
    "but if this works for SCOM 2007, it should apply to SCOM 2012"
    is not accurate when it comes to network monitoring:
    http://blogs.technet.com/b/momteam/archive/2011/10/24/migrating-operations-manager-2007-network-monitoring.aspx
    Would it be recommended to use http://xsnmp.codeplex.com/ on SCOM 2012? 
    The codeplex solutions for SCOM 2007 R2 will not work on a new \ clean install of SCOM 2012 (if you upgrade from SCOM 2007 R2 they continue to work as legacy devices but you can't add more monitoring).
    SCOM 2012 seems to be able to recognize the model of only Dell Powerconnect 5224 switches
    What do you mean by recoginse? SCOM can discover network devices but there is an "approved" list that allows for extended monitoring:
    http://www.microsoft.com/en-us/download/details.aspx?id=26831
    You should still be able to discover and monitor other devices though:
    http://blogs.technet.com/b/momteam/archive/2011/09/20/what-gets-monitored-with-system-center-operations-manager-2012-network-monitoring.aspx
    Cheers
    Graham
    Regards Graham New System Center 2012 Blog! -
    http://www.systemcentersolutions.co.uk
    View OpsMgr tips and tricks at
    http://systemcentersolutions.wordpress.com/

  • Is there way to Monitor Live camera from SCOM 2012 R2

    Is there way to Monitor Live camera from SCOM 2012 R2 ?
    Thanks 
    Raja R
    Raja R

    Depends what it is that you want to monitor?
    If it's an IP camera that supports SNMP, you can monitor multiple components, depending on the manufacturer (e.g. # images captures, uptime in hours, ...).
    If it doesn't support SNMP, you can monitor it through ICMP (ping). Then it's only possible to monitor the state of the device (up/down) depending on wether scom receives a ping reply or not.
    If it's a coaxial camera or something else, not connected to a network, it's not possible to monitor the camera itself. Might be possible to monitor the computer/DVR that records the images.

Maybe you are looking for

  • RFC login and user creation to remote system

    Hi there, Hopefully this is the related forum for this question. We have a scenario where we need an automated process to create users on one system and then create just the same account on a remote system with deactivated password. How is this best

  • Reading the .rno files

    Experts, Here is my requirement. I am getting below menction file with extension (.RNO) XI needs to read that file and map to ORDERS05 Idoc send to R/3 system. this file includs digital certificates also. I see they are couple of tags in this file wh

  • Using iTunes from another mac :)

    Hello, is there any app (for mac) which allows me (or somebody) play/pause/skip/... music played on another mac? Something like the remote.app for iPhone. I have mac, playing some music via Airport Express. When my girlfriend doesn't like the song, s

  • The specification is in read mode?

    I created a material spec and add some data to nutrition & compliance tab, then run CACS. it also in draft status, but its edit button is disappeared. I create a issue for the spec. and modify something and save. it appear a message said "the spec is

  • Mandatory field in report

    Hi, I have a date field on report. Now this needs to be mandatory and report should be run in batch mode with a variant. Also when the report is run the first time the date should not be taken from the selection screen input but from TVARV, this is f