Hello,
I am a graduate student and new to labview program, I have spent my couple of weeks to learn about labview and data acquisition techniques in labview. So far I  am able to code a program as attached (block diagram) which basically runs only at highlight execution mode. I need to run the program throuhout the test period and record all the datas. I have NI- SCXI 1001 hard ware device  and 2013 labview. I need to read from multiple channel at a time though it seems to be doing with this code. The output as attached is also not clear. I want the output to be tabulated with topic like Load, Stroke, Potentiometer 1 and Potentiometer2 etc. Please all help me to solve this problem. Your suggestions are highly appreciated.
Solved!
Go to Solution.
Attachments:
block diagram.PNG ‏13 KB
front panel display.PNG ‏42 KB
out put2.txt ‏1 KB

Dear Dennis,
I have incorporated your comments and also revised from my side, now it is working  little bit, I still wants to improve its functionality in the area of displaying graph, and time flexibility, please suggest me. If you have any informative links and documents regarding data acquisition please convey to me.
I have attached screenshot of block diagram for your kind information.
Attachments:
block diagram-27 march.PNG ‏20 KB

Similar Messages

  • Z600 workstation missing pci data acquisition and signal processing controller driver

    I just installed Win7 Pro x86 on my Z600 workstation.  It was an upgrade from WinXP Pro.  In Device Manager I am missing the driver for the PCI Data Acquisition and Signal Processing Controller and Hardlock USB 1.02.  Can someone assist me in finding these drivers.  I looked on the Support/Drivers page for this  model but couldn't find anything.
    This question was solved.
    View Solution.

    Hi,
    You might get better assistance on the HP Enterprise Business Forum since you have a professional worktsation.
    HP DV9700, t9300, Nvidia 8600, 4GB, Crucial C300 128GB SSD
    HP Photosmart Premium C309G, HP Photosmart 6520
    HP Touchpad, HP Chromebook 11
    Custom i7-4770k,Z-87, 8GB, Vertex 3 SSD, Samsung EVO SSD, Corsair HX650,GTX 760
    Custom i7-4790k,Z-97, 16GB, Vertex 3 SSD, Plextor M.2 SSD, Samsung EVO SSD, Corsair HX650, GTX 660TI
    Windows 7/8 UEFI/Legacy mode, MBR/GPT

  • Driver missing - PCIe Data Acquisition and Signal .....

    Hello, i recently used Boot Camp to install Windows XP on my 2010 15" Macbook Pro.
    All the drivers are working (so far) and i haven't encountered many problems.
    However, there is one thing bugging me:
    When i go into Device Manager in Windows, and look down the list of installed/uninstalled devices, there is a device called "PCIe Data Acquisition and Signal Processing Controller" which has no driver installed.
    I'm PC savvy, but i have never seen this before. My guess is that one of the motherboard drivers is missing, and Boot Camp installer doesn't include that driver?
    Has anyone seen/resolved this, and if so, how?
    Thanks.
    Kaj.

    Okay, will do.
    Thanks.
    Also i wonder if you could help with another problem?
    http://discussions.apple.com/thread.jspa?threadID=2758766&tstart=0

  • PCI Data Acquisition and Signal Processing Controller driver

    I've installed win 8.1x64 on my HP Probook 450 G2 but I am missing the PCI Data Acquisition and Signal Processing Controller driver.
    Can you please help?
    Thanks,
    Leontina
    This question was solved.
    View Solution.

    Hi:
    Please see if installing the Intel Chipset driver installs that device.
    https://downloadcenter.intel.com/Detail_Desc.aspx?DwnldID=20775&lang=eng&ProdId=816

  • Pci data acquisition and signal processing controller -Device software not installed

    My pc shows me ,the driver software for pci data acquisition and signal processing controller is not installed  on my Device manager.
    Please suggest me a suitable solution.

    No its not working , Give me an alternate solution.

  • Data acquisition from SR 530 lockin

    Hello,
    I need to read the output of the sr530 vector lockin and store them in a file.
    I was wondering if there is any driver which will let me read frequency, output amplitudes & relative phase between the input & output signal!
    Any help will be much appreciated!
    Thanks a lot,
    Ashutosh.

    Thanks a lot for the help Matt.
    I can connect the device via GPIB. Let me tell you a bit more about the problem. As of now I was using a single channel lockin, EG & G 5209, to read the data(so I am kindda familiar wtih data acquisition... not much though). And the only thing I was reading was the output amplitude of the lockin.
    Now I have to use the vector lockin, SR 530, and I will need to read both the output amplitudes, the phase & the frequency (all four of them)at the same time. And I am looking for a driver which can do this, i.e. which can read all four data simultaneously & store the result in a *.txt or *.dat file.
    Do we have something like that?
    Thanks,
    Ashutosh.

  • Data acquisition in a state machine

    I've recently learned how to implement state machines, but I have a question that I haven't been able to find an aswer to.
    Question:
    How do I record uninterupted data (presently i'm using the DAQ assistant to record a single channel at 10kS/s at 1kS intervals) without interfering with my state machine?  
    Background:
    I have a time sensitive test setup (measuring pressure in a rocket chamber), and I'm using labview to both record a single pressure transducer as well as operate the valves (O2, N2, igniter, etc).  I'm using a state machine Labview architecture (just learned how).  Presently, the DAQ assistant sits in the "Idle" state, and timers (valves need to be turned on at specific times) and manual buttons control when the other states are activated.  I have a 10ms timer controlling how often each state is run, and this is the root of my concern.  
    Main concerns:
    I'm worried that:
    1)  I'm forced to change my data recording to 10ms intervals to match the 10ms timer, and
    2)  The 10ms timer will interrupt my data recording when it's in another state.  
    It's very important that the pressure data is recorded without interruption but that I have high time resolution in controlling my valves as well.
    Thoughts:
    1)  Maybe I put the 10ms timer in the "Idle" state only, and this way the other states won't interrupt the data acqusition
    2)  Maybe there is a way to completely isolate the state machine for controlling the valves and the data acqusition.  I'm not sure how to do this.
    3)  People on the forums have been talking about Queuing their data acqusition, but I'm not sure how this would benefit my situation.  
    Thanks to everyone for their feedback!

    The data acquisition and state machine timer do not have to be equal, you should however have the same data write rate as you have data read rate, otherwise over the course of long running programs you can build up a large buffer of data to be written using a lot of memory, or lose data.
    Your data acquisition should be continuous, the most common way of doing this is every time you receive data write it to a queue, then when you are in other states except your data write stage you simply build up data in the queue that is to be written when you enter the write state again.
    Think of it as traffic reaching a set of lights:
    The traffic represents the data acquisition, there is a constant flow of it always coming through, the state of your state machine is the lights, green is the data write state clearing the queue, red is when in any other state, letting the traffic build up behind the lights.
    It is just important that the light is green long enough to let the traffic not build up too much, otherwise you have a jam.
    EDIT: For the basics of how queues work, look at the Queue basics example from the example finder. 

  • Data acquisition from multiple channels.

    Hello
    Right now, I am able to acquire the signal from a single load cell and display it.But I would like to know of how to acquire  acquire signals from two load cells simultaneously.I am using Labview 6i and I am using AI S-Scan with AI config to acquire the waveform.It would be of great help if you could suggest a simple method to acquire the signals.
    PS: Please find the attached file used for acquisition from a single load cell.
    Looking forward for your reply.
    Manasa
    Attachments:
    test 4.vi ‏102 KB

    Hi Manasa,
    If I understand what you are trying to do, it is relatively
    straightforward to configure your application to acquire data on two channels.
    I was unable to run your vi as it was missing some of the subVI’s
    from your application.  However, your
    attachment was sufficient to see what you are trying to do. 
    Here is how to add channels:
    1.      
    In the I/O Channel Constant, you can add
    additional channels by using a comma or a semi-colon.  For example, to scan the first four channels
    you would put 0:3 in the constant (see attached screenshot ChannelConfig.jpg).  To scan the first and third channel you would
    put 0,2.
    2.      
    The AI Single Scan VI will now read from
    multiple channels.  Often it easiest to
    configure the output of this VI for viewing by first putting the data into an
    array using the Build Array VI.  It can
    then be plotted in a waveform graph. (see attached screenshot ReadtoGraph.jpg
    and WaveFormGraph.jpg)
    Just a few notes about “simultaneous” sampling:
    Most of the NI data acquisition cards have a multiplexer
    between the various input channels and the Analog to Digital (A/D) converter
    creating a very small delay between each channel (usually ms range or
    smaller).  NI does make several data acquisition
    cards that can perform true simultaneous sampling, meaning that there is an A/D
    converter for each channel.
    For the large majority of applications, the small delay
    between channels is negligible.
    Jared T.
    Attachments:
    ReadtoGraph.JPG ‏21 KB
    ChannelConfig.JPG ‏288 KB
    WaveFromChart.JPG ‏61 KB

  • Data acquisition from switching 500lbs load cell to 100lbs load cell

    I am using 500lbs load cell, and acquiring data by inputing 2volts from 2345 signal conditioning board, and sensor output is connected to SCC-AI03 pin 3 and 4 , and configure this load cell to a channel using NI MAX, data neighborhood, traditional NI-DAQ virtual channel, the physical quantity is voltage set at range -10 to 10, and sensor also set at voltage with no scaling, but, I couldn't get any signal when 100lbs load cell is use, the difference of this 100 lbs load cell is the rated output is at 2.958mV/V, while the 500lbs rated at 1.8295mV/V , how should I do this?
    Thanks.

    Hi,
    At this point, it is difficult to determine exactly what is happening to your acquisition. Could you please provide some additional information by answering the following questions:
    What voltage are you reading with the 500 lb load cell?
    Would it be possible to connect your load cells to a DMM and see what voltage reading you receive? If so, what do you see?
    What is specifically happening when you connect the 100 lb load cell?
    I also noticed that you are using the Traditional NI-DAQ (Legacy) driver. I recommend upgrading to the NI-DAQmx driver.  Here are a couple of links with more information about DAQmx:
    Advantages of NI-DAQmx:
    Transition from Traditional NI-DAQ to NI-DAQmx:
    Learn 10 Functions in NI-DAQmx and Solve 80% of Data Acquisition Applications:
    Regards,
    Hal L.

  • Data acquisition driven by encoder

    Hi everyone,
       I need to sample a capacitive sensor that measures the radial run-out (radial small displacement) of a rotating spindle. LabView v. 7.1 is employed to acquire the data by means of PCI-6036E card commercialized by National Instruments (NI). The spindle rotates at 100 rpm and a rotary incremental encoder is fixed at rear of spindle. The encoder gives two types of digital pulses as follows: a) A-quad-B pulses (it will be used only “A” pulses in this experiment); b) index pulse (one pulse per revolution). This encoder provides 1024 pulses type “A” per revolution. The measurements made by the sensor are driven by “A” pulses which are used as “external clock”. Therefore, every “A“ pulse, the card acquires one sample from sensor. Thus, 1024 data/rev are acquired. I want to sample 5 consecutive revolutions of the spindle. To start the data acquisition, the index pulse of the encoder is used as “start digital trigger”. Also, the index pulse should be used to count the number of revolutions of the spindle. In this way, when the number of revolutions is equal to 5, the data acquisition finishes. By contrast, the programmer also can set the number of samples equal to 5x1024 in the VI. The data acquisition is finished when the number of samples reaches this value. Similarly, the sampling process is started by the index pulse which is the “start trigger”. Note: 1) the sampled data should be put in a buffer. After the sampling process is finished, this data should be saved in a file of LabView; 2) In fact, the data acquired by the sensor are voltage analog input. Questions:1) Could you make a VI for this problem, please? Note: You can use the DAQ ASSISTANT EXPRESS VI or DAQmx TASK NAME CONTROL method.2) How to program the LabView in order to sample data triggered by the rotary encoder (pulse “A”)?3) What should I do to stop the data acquisition at the end of 5 revolutions?4) Could you send examples (VIs) similar to my problem above?5) How can I know if the program (VI) looses an “A” pulse? Is there any kind of error in VI that indicates a miss pulse?  In anticipation, thank you very much for any help. My e-mail: [email protected]                                                                                      Bruce

    Hello Bruce,
    I have a complete solution for this but I cannot give you the VIs because my customer has paied for it and all rights are transfered to him.
    What you need are two tasks.  One task is the analog in task. You must use the DAQmx Timing.vi and the DAQmx Trigger.vi to set it up as needed. Or you create a task in MAX with this setup. The other task is a counter task just counting the pulses from the z-Index.
    Next you need a small state machine with the states:
    init, start, wait and stop.
    init will initialize and start the tasks
    start will read out the z pulse counter and wait for a change from 0 to 1
    wait will read out the z pulse counter or the available samples property, when the desired number of z pulses or samples are available read the buffer with DAQmx Read.vi
    stop will stop both tasks and clear them.
     You will need two additonal counters which you don't have to check for lost A pulses and a external flip-flop electronic. The flip-flop will change it's state with each z pulse and the output will be used for gated counting. With each change of the z pulse counter you need to read out one of the additional counters to check if he had seen the correct number of pulses.
    Waldemar
    Using 7.1.1, 8.5.1, 8.6.1, 2009 on XP and RT
    Don't forget to give Kudos to good answers and/or questions

  • Data acquisition on the basis of time

           Hi everyone,
    I want to acquire the radial run-out (radial small displacement) of a rotating spindle using a capacitive sensor. To do so I will use the LabView v. 7.1. The PCI-6036E card from National Instruments (NI) will be utilized for data acquisition. The spindle turns at 100 rpm and a rotational incremental encoder is fixed at rear of spindle. This encoder provides an index digital pulse per revolution. This pulse should be used to start and finish the sampling process. I want to sample on the basis of time, by means of sampling rate of the card (Ksamples/s). So, let us suppose that I want to acquire 500 data/rev. The spindle takes 0.6 sec to complete one revolution. Thus, the required sampling rate is Fs = 500 samples/0.6 s = 833 samples/s. So, I should set the VI in LabView so that it samples only 833 data/s. Therefore, I will have to reduce the sampling rate of the analog-input channels in use. For example, let us suppose that the card provides 100 Ks/s when operating in multiple channels. Let us admit that there are 4 analog-input channels in use. So, the scan rate per channel is 25 Ks/s. This is too much for this application. I only need 833 samples/s. So, I should program the VI so that the card provides that required sample rate. As said earlier, I need to start and end the sampling process at the same point. Thus, to do that the index pulse of the encoder will be used. Also, I want to sample during 5 consecutive revolutions of the spindle. So, by means of a loop in VI, I should count the index pulse of encoder until the number of pulses be equal to 5 (= number of revolutions). At this instant, the sampling process should be stopped. Note: 1) the sampled data should be put in a buffer. After the sampling process is finished, this data should be saved in a file of LabView; 2) In fact, the data acquired by the sensor are voltage analog input. Questions:1) Could you make a VI for this problem, please? Note: you can use the DAQ ASSISTANT EXPRESS VI or DAQmx TASK NAME CONTROL method2) What should I do to stop the data acquisition at the end of 5 revolutions using the index pulse of encoder?3) Could you send examples (VIs) similar to my problem above? In anticipation, thank you very much for any help. My e-mail: [email protected]                                                                                      
     Bruce  

    duplicate post
    Continue in other thread
    Message Edited by smercurio_fc on 11-14-2008 09:10 AM

  • Data Acquisition for Position Transducer

    I just purchased an Analog Position Transducer from SpaceAge Control, and was wondering if anyone had any code to gather the data. I must admit i'm lost when it comes to this, I thought the transducer would come like an instron where you just plug it into the computer. I have a six pronged plug that exits the device. I have a couple TI data acquisition boards at my disposal. I am hoping someone has used a similar product or has some advice. Thank You
    Keith

    We have lots of code to gather data in all sorts of ways. Building measurement applications is what we do. Since you are lost when it comes to this, you would do well to hire a guide in the form of an Alliance Member company. We do this stuff every day.
    Your TI DAQ boards may do the trick, but you would have to show someone the specs for them. Also, you need to think about what kind of speed you require and where you want the position data to go. Table? Plot? Database? A good LabVIEW developer can set you up with some code that does exactly what you want.
    Daniel L. Press
    PrimeTest Corp.
    www.primetest.com

  • Data acquisition from NI PXI 5152 using LabVIEW

    Hi,
        This might be really stupid question, I am new to LabVIEW and the Digitizer equipment. I was wondering if there are already any labVIEW based application available to read the data from PXI5152. I would be using both channels available and may be trigger. If there is no such application available, what would be port numbers I would be using for data acquisition. But, If I am to develop an acquisition software, I would be looking at every single specification of the equipment. I am assuming the output will be a digitized signal varying with the clock input, since It is used as oscilloscope. When working with labview how would I specify the port to read from and how would my PC recognize the port. I working on a pre-configured system and they won't let me unplug anything to check the configuration. Does NI provides a software to read into the signal fed into the channel and trigger inputs. I have tried looking into the different forum discussion but didn't find any that address my issue. May be it's too simple and stupid. But, it would be a great help if you could point out my misunderstanding.
    Thanks in advance.
    BP

    There are numerous examples. Help>Find Examples> Modular Instruments>Ni-Scope. There is a test panel available in MAX. On the Measurement I/O>NI-Scope palette, are all of the driver functions includeing the NI-Scope Express.
    I'm not quite sure I understand your references to 'port's. Once installed into the chassis, it should be listed in MAX. In the functions you will be using, there will be a dropdown menu that you will be able to select the scope resource name.

  • Data acquisition time of ocean optics spectrometer

    Hi, LVers,
    I has a S2000 multichannel fiber optic spectroscopy system. It includes two channels, master and slave. Additionally there is a channel labeled as 'LS-1'. I use labview and driver OOILVD32.dll to control this spectroscopy. In OOILVD32.dll, I use vi 'OOI SCAN' to acquire spectral data through master channel.
    In vi "OOI SCAN", I disable all slave channels (there are 7 slave channels) and enable master channel only. However, I find that the data acquisition time is always approximately two times of the "sampling frequency" we set. E.g. for sampling frequency of 75 ms (a small value), the spectral data acquisition time is approx. 160-170 ms; for a sample frequency of 4000 ms (a large value), the spectral data acquisition time is approx. 8300-8400 ms, so on and so forth.
    I am very confused with this phenomenon. I guess the most probable reason is that both master and slave channels are always enabled even one of them is software disabled. Because this product is discontinued, I can not find the manual. Anybody could advise me how this such a spectrometer works internally? Is there any multiplexing acquisitions inside?
    Thanks in advance.

    Hi Hello183,
    Unfortunately, I do not know how your specific device works, however, I did find the product page for this device on the Ocean Optics web site, which points to the USB4000-series Plug-and-Play Spectrometer for more details. There seems to be a operations manual for this device. Perhaps this can shine some light on how the sampling works for your device as well.
    Aaron P
    National Instruments
    Applications Engineer
    http://www.ni.com/support

  • Data acquisition synchronisation Arduino/LabView

    Hello,
    I'm trying to acquire force sensor values using an Arduino board (reading the data and controlling a motor) and LabView. The data acquisition rate is tunable according to the motor condition, meaning a high acquisition rate (short delay) during the ON state of the motor and a low acquisition rate (long delay) during the OFF state of the motor.
    I managed to acquire the data, but till now I always find some "0" values though I'm applying a continuous force on the sensor. I guess the main problem is the synchronisation of the "datarate" on the Arduino board and the acquisition time point in LabView.
    I hope that you could halp me, since I'm trying since weeks to overcome this problem. You will find both the LabView and the Arduino source codes in the attachment.
    Attachments:
    CBR control_opti.vi ‏206 KB
    CBR_Arduino.docx ‏15 KB

    Dear all,
    last week I had some limited time, which I could dedicate to my work with Labview. Unfortunately I'm not able to solve the problem with the Consumer/Producer architecture. It seems to be the appropiate solution, but due to my limited knowledge I'm not capable of doing that.
    I will add my modifications (CBR control_Prod-Cons.vi) to give you an idea about what I've achieved so far. I appriciate any help of you, since this story is driving me crazy. Additionally, I attach a JPG showing the readout I'm obtaining with the old version (CBR control.vi), where the red circles indicate the problem with the "0" values.
    Thank you again,
    Cheers 
    Attachments:
    CBR control_Prod-Cons.vi ‏203 KB
    sensor read out.JPG ‏164 KB
    CBR control.vi ‏206 KB

  • Data acquisition & state machine

    Hi all,
    I am working on a project that is capable of data acquisition, analyse, and record processes. I have to acquire data of temperature from 8-32 channels and that of pressure from 7 channels. After analysis, I have 48 outputs. I want to record raw data (acquired) and analysis data at the same time.
    1) Is it possible to record two text files (raw data and analysis data records) at the same time?
    I also want to adjust acquired sample rate but I have doubts about utilizing it in a state machine. For now, I have just used time elapsed function to acquire data once in 60 seconds.
    2) How could I set sample rate of acquisition except using time elapsed function?
    I also have one more doubt about timing. If I needed to acquire sample once in 60 seconds, but the analysis took more than 60 secs, what would happen?
    3) How can I prevent data loss in this case?
    I have not prepared a user interface yet.
    4) How can I utilize it? Do I put graphs and indicaters in the same VI or is it better to prepare another vi just for user interface?
    Thanks in advance
    Egemen
    Attachments:
    Program.llb ‏433 KB

    Hi Egemen
    -          If we need to acquire data and analyze it at the same time we recommend the architecture producer-consumer to prevent data loss, and yes you can record two text files at the same time. Please take a look to this architecture.
    -          http://www.ni.com/white-paper/3023/en
    -          Basically you use the first loop to acquire data and the second one to analyze and record data (using queues).
    -          https://decibel.ni.com/content/docs/DOC-2431
    -          You can also find examples about this architecture at the developer zone.
    Regards

Maybe you are looking for

  • Report problem

    Hi, I have report which is having two columns job start date is in one table and job id is another table job startdate, job id 01-Feb-2013 06:12:33 AM,121 02-Feb-2013 08:30:00 PM,122 01-Feb-2013 11:30:00 PM,121 02-Feb-2013 09:12:33 AM,122 03-Feb-2013

  • Re importing photos, album, etc from an external drive

    Recently my I photo library (incl. over 6.000 photos, books already ordered and others still working on, slide shows etc,) was gone. Thanks to the advise I got from Terence  (apparantly I deleted my library, and  I did not have any back up) - buying

  • Why upgrade from Keynote 2.0 to 3.0?

    For Keynote users who have upgraded from 2.0 to 3.x, what are the two three biggest differences, features, reasons you have found it to be worth the change? I own a copy of iWork '05 with Keynote 2.0. I just bought a new MB Pro and understand from th

  • Airport Extreme worked for 2 days and now wont

    3 days ago I wasted $600 on an Airport Extreme, 500Gb external drive, and the family pack of leopard excepting to use time machine with the shared airport disk. I quickly realized that wont work, maybe they'll fix it one day. What really ***** though

  • Moving library from desktop to laptop

    I have i-Tunes 7 on both my desktop and laptop; but my main library is on my desktop. I want to be able to move my library from the desktop pc to the laptop, INCLUDING playlists etc. I don't mind replacing the laptop library with the desktop library,