Data Source 2LIS_11_VAHDR deliver rows with mode "Delta init. without data"

Hi.
I have the problem, that my datasource 2LIS_11_VAHDR does deliver the full content like mode C even with mode S. Does somebody know about the problem and how to solve it (perhaps OSS).
Thanks in advance,
Nils

To see the delta data, we use trandaction code RSA7. is that right? This is the place i used to view the delta data after every document changes.
per say: If I have 2 line items in a sales order and I have increased the quantity of one line item and saved it. The delta maintenance transaction shows me 3 records. 2 for changed line item and 1 for unchanged line item.
Please tell me why I have 3 records of data in delta table.  Please clarify.

Similar Messages

  • DTPs - Delta Init without Data transfer.

    Hi All,
    I am implementing the DTPs in my project where we replicate the old 3.x extractions with the bw7x functioanlity;
    Can anyone tell me if their is way to implement the "Delta Init without Data transfer" scenario with DTPs for
    both R/3 to BW(ODS) extraction or for the Datamarts - ODS to Cube within BW??
    Thanks in advance!
    Cheers
    Rao

    Hi Rao,
    Yes u can achieve Initialization without data in BI 7 DTPs.
    Goto ur DTp's Execute Tab, and Processing mode there drop down the list and select No Data Transfer,Delta Status in Source: Fetched.
    Assign points if helpful.

  • Init without data transfer

    Hi sdn
    my data is going form ods to cube and i already done full update from Source system now we want to do init without data transfer but when I'm seeing in monitor then requst is running for 5 hrs still yellow and when i cancell that request then run it again the when I press start load button then it ask me for ods activation for all request and for one request i had tried either way but didn't got successful, what to do we are using generic datasource
    rubane

    Hi,
    I think you are doing data upload to ODS .
    In the seetings of ODS Select Automatic Activation.
    Since you have cancelled the data upload,So delete the Data from the ODS . And then Do Delta init with out data transfer .and then do full upload. But when you are doing full upload you have to make it as Repair request. And then continue Delta loads.
    Once Delta init (with out data transfer) and Full upload is over to ODS ,you can start Delta init upload to Cube.
    With rgds,
    Anil Kumar Sharma .P

  • Initialize Delta Process without data transfer

    Dear Gurus,
    I am facing a problem when I try to "initialize Delta Process without data transfer" an ODS.
    I first deleted the initialization request in Scheduler->Initialization Options for Source system and then I executed the Infopackage.
    The status of the new init. request is red and I get the following error message :
    Request REQU_DMJI1J66397EM5OZMC1EQJLWZ (192.384) for DataSource 8ZSALETXT from source system PW1CLNT600 has the status green and a lesser SID (and is therefore older) than the request that you currently want to update into the DataStore object.
    This is not possible because the sequence of requests has to be followed.
    Delta- and init requests have to be updated to the DataStore object in the request sequence.
    The problem is that I can't find this request (REQU_DMJ...) anywhere.
    Could you please explain me what to do with this issue and tell me if it is possible to make the system just ignore this request ?
    Thank you in advance
    Fabien

    Hi............
    U r not able to find REQU_DMJI1J66397EM5OZMC1EQJLWZ in the Manage screen of the ODS right?.........
    Go to RSRQ...................give this request number and check...........if the Status is green........in the Header tab check whether the load is till PSA or not............if it is till PSA............then go to the Status tab and click on Process Manually to push the request in the target........otherwise just make the QM status red here..............then do the load.......
    Regards,
    Debjani.........

  • SharePoint PPS 2013 Dashboard Designer error "Please check the data source for any unsaved changes and click on Test Data Source button"

    Hi,
    I am getting below error in SharePoint PPS 2013 Dashboard Designer. While create the Analysis Service by using "PROVIDER="MSOLAP";DATA SOURCE="http://testpivot2013:9090/Source%20Documents/TestSSource.xlsx"
    "An error occurred connecting to this data source. Please check the data source for any unsaved changes and click on Test Data Source button to confirm connection to the data source. "
    I have checked all the Sites and done all the steps also. But still getting the error.Its frustrating like anything. Everything is configured correctly but still getting this error.
    Thanks in advance.
    Poomani Sankaran

    Hi Poomani,
    Thanks for posting your issue,
    you must have to Install SQL Server 2012 ADOMD.Net  on your machine and find the browse the below mentioned URL to create SharePoint Dashboard with Analysis service step by step.
    http://www.c-sharpcorner.com/UploadFile/a9d961/create-an-analysis-service-data-source-connection-using-shar/
    I hope this is helpful to you, mark it as Helpful.
    If this works, Please mark it as Answered.
    Regards,
    Dharmendra Singh (MCPD-EA | MCTS)
    Blog : http://sharepoint-community.net/profile/DharmendraSingh

  • Does "Init without data transfer" creates delta queues?

    Does "Init without data transfer" creates delta queues?

    Hi,
    Yes, Once initialization successful for particular source system, you can see entry at Delta Queue(RSA7).
    Hope it Helps
    Srini

  • Init without data transfer is not working in the Production box for FICA extractors

    Hi Guys,
    We are unable to do Init without data transfer for FICA Extractors(0FC_INVDOC_XX) from BODS system. And the job is successfully completed from the BODS end but it is not hitting the source system.. Can any one please let me know how to resolve this issue.
    Thanks,
    Kovur

    Hi,
    After triggering your info pack with init without data transfer, are you able to see delta pointer at info pack-->scheduler--> init options source system.
    Are getting any error message? if yes then please share here.
    Thanks

  • For Init without data transfer showing records 0 from 0

    Hi all,
    Iam doing Init without data transfer to ODS. In the ODS manage it is showing 1 from 1 which is correct. This ODS data is automatically updated to a cube. There in the cube manage it is showing 0 from 0. My mappings in update rules also correct , but why it is not giving 1 from 1.
      In the cube manage the status is showing green but in the monitor of cube always it is yellow.
    Help me please
    Ram

    Hi Ram
    If you load data with INIT without data transfer then system shows the defualt record in the monitor.
    If check that record in the PSA then you dont find it and on the cube as well.
    If the load is green with 1 record then extractor working fine.It's not actaully a data reocrd.
    Hope it helps...
    Regards,
    Chama.

  • STANDARD DATA SOURCE 2LIS_11_VAHDR NOT GETING DATA

    RESPECTED GURUS
    I AM A NEW BI USER. I AM TRYING TO EXTRACT DATA FROM 2LIS_11_VAHDR WHICH IS A STANDARD DATASOURCE THROUGH RSA3, BUT I AM GETTING A MESSAGE "0 RECORD FOUND" BUT THERE ARE PLENTY OF DATA. I WAS TRIED WITH THE OTHER STANDARD DATA SOURCES AND GETTING THE SAME MESSAGE" ZERO RECORD FOUND".PLS GUIDE ME HOW I WOULD I GET DATA.
    REGARDS
    ABHAY MAHODAYA

    Hi Abhay,
    The data source which you are trying to use is comes under logistics. To take the logistics data from R/3 to BW set up table needs to be filled up. To fill the set up table follow the below mentioned procedures.
    First Delete the set up table to avoid data duplication:
    Go to T.Code: SBIW -> Settings for Application Specific data sources (PI) -> Logistics -> Managing Extract structures -> Initialization -> Delete the contents of the setup table
    Fill the set up table:
    Go to T.Code: SBIW -> Settings for Application Specific data sources (PI) -> Logistics -> Managing Extract structures -> Initialization -> Filling in the setup table -> Application specific set up of statistical data
    Choose the relevant node to perform the set up based on your requirement.
    Remember while filling the set up table no entry sould get posted in the relevant tables. So while you do this in production system, you may have to request for user locking for the relevant T.Codes.
    All the best.
    Regards,
    Sarath.

  • First load with DTP with mode Delta

    Hello Experts,
    I'd like some suggestions based on the following scenario.
    DSO-A
    - total records = 44,000,000
    - with criteria X = 230,000
    DSO-B (New DSO)
    - due to this DSO is a new object. It is required to retrieve data from DSO-A with criteria X
    - this means that the target records to be added are 230,000 records
    - DTP for extracting data from DSO-A to DSO-B --> use Extraction Mode = Delta
    Questions
    - For the first time loading, how to extract data in small chunks at a time from DSO-A to DSO-B when Extraction Mode is set to Delta?
      I have concerns on performance if data were loaded all at once with Extraction Mode = Delta. I do not want to interrupt other existing schedule jobs much.
      After the first load, this DTP will be set to be run daily. The next day, data will not be loaded in huge amount again.
    Any best practice on this.
    All suggestions would be appreciated.
    Thank you very much.
    -WJ-

    *- For the first time loading, how to extract data in small chunks at a time from DSO-A to DSO-B when Extraction Mode is set to Delta?*
    When you are loading first time from DSO-A to DSO-B using DTP it acts like Full load only, even if you keep that as Delta mode, then for further loads it takes as Delta load. If you have any selections active for that we can load small chunks using the Filters option in the DTP in the Tab Extracion.
    I have concerns on performance if data were loaded all at once with Extraction Mode = Delta. I do not want to interrupt other existing schedule jobs much.
    You have just 230,000 records to be loaded, i dont think it gives any performance issues. We can load it.
    After the first load, this DTP will be set to be run daily. The next day, data will not be loaded in huge amount again.
    Yes for further loads from this DTP gets only delta records hope they are fewer.
    Hope this helps.
    Veerendra.

  • Switching Data Source for a report with stored procedure

    Post Author: ysbn
    CA Forum: Data Connectivity and SQL
    I've created a report and deployed it on a Crystal Server. The report is based on a certain stored procedure which also exists on other DB machines in my environment (Oracle machines). When I try to switch my report object to work with other machines (not the one originally used when the report was designed) the activation of the report fails. The error I see in the preview window is:
    Error in File <my rpt file name>: Failed to retrieve data from the database. Details: &#91;Database Vendor Code: 6550 &#93;
    When I try the same thing with a report which is based on a view and not a stored procedure the switching of Data Source works perfectly.
    Is there a problem switching between data sources from the server when the report is based on stored procedure? Are there any configurations I need to do in order to support this scenario?
    Thanks!

    Hi everyone~
    i am now facing the same problem
    i am using CR2008 and Visual Studio 2008 c# to write a window program
    because we have 2 db environment (one is production , the other one is development) so i have set a prarameter to switch db connection in c# code.
    the database is Oracle, and the the report will connect to Oracle procedure (which it is stored in package) this procedure will return reference cursor, so the report will loop up this cursor to generate report.
    at first time, it work fine when i open the report in CR2008 designer and point to dev database (ie datasource point to oracle procedure) . but when i want to deploy this win application to client and point to prod database, it show (vendor error 6550)
    i found that i cannot change the datasource during runtime in c# code...
    am i miss something in code? here attached a part of this code...
    private void setDBLogonForReport(ConnectionInfo info, ReportDocument doc)
                Tables myTables = doc.Database.Tables;
                foreach (Table myTable in myTables)
                    TableLogOnInfo logOnInfo = myTable.LogOnInfo;
                    logOnInfo.ConnectionInfo = info;
                    logOnInfo.TableName = myTable.Name;
                    myTable.ApplyLogOnInfo(logOnInfo);
                    //myTable.Location = info.UserID + "." + "pkg_crystal_report." + myTable.Name;
                    //someone suggest i have to set the 'Location' for change the datasource, but i am not sure how to construct a 
                    //string for point to oracle prcedure
    i will check it freq ... hope any expert can give me some advice ~
    thank you very much!!!

  • WebLogic 11g data source connection pooling failed with IO error:socket read timed out.

    Hi all,
    We encountered IO Error: Socket read timed out( <Received exception while creating connection for pool "DS_1": IO Error: Socket read timed out> ) during the creation of data sources in WebLogic 11g. Manual data source testing seems to indicate intermittent connection and the server seems to take a long time to start up with multiple IO errors. We increased the timeout at the database side but it does not seems to help. The database is 11g (11.2.0.3). The database services and listener are up which does not indicate that the database instance is down.

    This particular error means your database is down and socket is timedout. Or the query takes so long that the reader timedout -- unlikely.
    Also, the general weblogic socket write errors, which you might see sometimes means that the client got disconnected before the server wrote results back. This is harmless

  • Data source 0PU_IS-PS_43 could not load delta updata

    In BW3.5, I install the Business Content of data source 0PU_IS-PS_43 to load the Budget Line Items in SAP system. Delta updata is support by data source 0PU_IS-PS_43.
    First, I did the Initial load in BW system, then I can see the delta queue in SAP system(t-code:RSA7). But after that, update of tables FMBH and FMBL triggered in Funds Management was not entered into the BW delta queue, in BW system I can not load any delta updata also. Can anyone tell me why? Did I miss any step which I should take?
    Thanks!

    Note 1024508 - No delta data for Funds Management DataSources

  • WCF Service as Data source in SSRS report with Complex Types

    Hi All,
    I have a requirement where we are suppose to use WCF service as datasource in SSRS. I was able to do that when the WCF response type was simple.
    Now the requirement have changed where the response type is complex . I couldn't figure out a way of accessing WCF with complex types.
    Any pointer will be of great help as I couldn't find any related articles for this kind of scenario.
    Raj

    Hi Raj,
    WCF uses a serialization engine called the Data Contract Serializer by default to serialize and deserialize data (convert it to and from XML). All .NET Framework primitive types, such as integers and strings, as well as certain types
    treated as primitives, such as DateTime and XmlElement,
    can be serialized with no other preparation and are considered as having default data contracts. Many .NET Framework types also have existing data contracts. For a full list of serializable types, see Types
    Supported by the Data Contract Serializer.
    New complex types that you create must have a data contract defined
    for them to be serializable. You can explicitly create a data contract by using DataContractAttribute and DataMemberAttribute attributes.
    This is normally done by applying the DataContractAttribute attribute
    to the type.
    You can refer to :
    http://msdn.microsoft.com/en-us/library/ms733811(v=vs.110).aspxhttp://www.codeproject.com/Articles/738844/Using-WCF-Data-Contract-Known-Types-by-Example
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.

  • Missing data-sources.xml deploying war with jdeveloper 9i RC

    When deploying a war file to an OC4J 1.0.2.2.1 server and error reports during the deployment that data-sources.xml is missing in the application-deployments/xxxx directory. Only the orion-application.xml file is present - which references a data-sources.xml file in the same directory. The problem is : it isn't there.
    When I copy the xml files from the applications/xxxx directory to the application-deployments/xxxx directory and redeploy the war file everything works fine.
    Is this a configuration issue or a bug ? Anyway, can somebody tell me how I can work around this problem ?
    Thanks !

    this is a bug and you have already found the workaround.

Maybe you are looking for

  • Unable to insert data in to database

    public String button1_action() { // Add your event code here... String pid = (String)textField1.getValue(); String pnam = (String)textField2.getValue(); String pjob = (String)textField3.getValue(); String pfre = (String)textField4.getValue(); try { /

  • Organization Units in Organization Structure

    Hi All, I want to have all the child org unit no's under a particular Org unit in the oganization structure tree. Can anyone help me with the function module ? For example : we have a tree like                  A                B    E              C 

  • PHOTO QUALITY COMPARISON

    People are not happy with Camera Quality of Z1, I am very disappointed. Tried many settings and it still can't beat a 13MP camera. Hope SONY takes this issue seriously & comes up with a good solution.  For reference & comparison, Check this link Belo

  • Archive & Install Failure

    After installing the 10.5.7 my mac was hanging repeatedly so I decided to do an Archive & Install. This procedure also "froze" so I shut down the system before it completed and now I can no longer boot. Adding to my stupidity I do not have a backup.

  • Cooling Fan Error Message & Computer Shut Down

    Hello, I have a 2 1/2 Satellite running W7 and recently started having a problem, receiving a Cooling System error message which tells me to shut down the computer immediately.  I did and left it off to cool, then started it up again.  Less than 5 mi