Data transfer Course BC420.
Hi,
I am planning to take a course on SAP data transfer BC420. I would like to know if this SAP course really helps in escalating the knowledge during projects or its not required since we learn the the things while working on project.
Rajesh
Hi Rajesh,
Data transfer in SAP using LSMW and BDC programs is pretty simple and easy to learn yourself. I would suggest you not to take the SAP BC420 because there is not much you gain from the course because the actual problems come when you really implement in a project and you will learn a lot while implementing it.
Regards,
Sudhir Atluru.
Similar Messages
-
We run a small network in our office consisting mainly of Intel iMacs we purchased several months ago. The server computer is a brand new Intel Mac Pro server with 4 500 gig drives raided together, two 2.66GHz dual core intel processors, all the other bells and whistles we could think of, etc. We added in two fiber-optic switches: one in the server room, one in the office. The switches connect to each other and the server with fiber optic cables, but the iMacs connect with ethernet cables.
We had the iMacs for a while but we just recently got the new server and upgraded our old 100 base switches. Afterwards we wanted to test out the data transfer speeds, as we plan to back up to the server frequently. We were dismayed to find that transfer rates capped out at 60 MegaBytes/sec according to the Activity Monitor's Network Activity tab. In fact, it would range mostly from 40-45MB/sec. None of us here have much experience with networking, but that seemed a tad too slow. My basic math tells me that a byte is 8 bits, and from that a Gigabit network should transfer data at 120 MegaBytes/sec, which is three times the speeds we were actually seeing.
We sent data both to and from the server in order to test this. Thinking it was perhaps a problem with the ethernet itself, we grabbed an external FireWire hard drive and transferred data from one of the iMacs directly to it and noticed exactly the same transfer rates. We plugged two iMacs directly into each other and transferred at the same rate, ~45MB/sec.
Well this was highly frustrating. All Macs supposedly ship with Gigabit ethernet since, what, 2002? Earlier? Why are our speeds so slow? We thought the hard drives might be slow, so we got info on the drives and googled them for their tech specs. The iMacs' Western Digital drives are capable of much much faster speeds according to everything we've read.
We started reading anything we could online that addressed this issue. Some information read the problem might be that the optical DVD-R/CD-R drive was only capable of slower transfer speeds. Since the optical drive and the hard drive are on the same bus it would slow down the hard drive's maximum transfer rate, much like having a Gigabit hub with a 10 base computer plugged into it would slow the entire network down (which is of course why we use switches instead of hubs). Is there any truth to this? If this is, in fact, the case, can we bypass this bottleneck somehow? I'm not talking about opening the computer and manually disabling the optical drive, as that's a waste of a perfectly good DVD-R/CD-R drive.
Also, if this is true, why in blue blazes is Apple flaunting Gigabit ethernet if the computer can only take advantage of 1/3 the speeds Gigabit ethernet has to offer?! I'll happily provide any more information that's relevant to the problem at hand.
Thank you
Mac OS X (10.4.8)Here's the specs for the default Hard Drive that Apple put in here:
http://www.westerndigital.com/en/products/Products.asp?DriveID=137
From that page
Buffer To Host (Serial ATA) 300 MB/s (Max)
Buffer To Disk 748 Mbits/s (Max)
I have no idea what signaling overhead for my data transfer protocol means.
The ethernet cords are no longer than 20 feet, are all Cat5E, and are well shielded. There is little to no ElectroMagnetic interference in any area they run. The longest cable is the Fiber Optic one, which runs about... oh... 40 yards? These were all installed by professionals.
I feel it's important to stress the fact that we tested an isolated direct computer to computer transfer with a single 6 foot Cat5E Ethernet cable and still experienced the same speeds that we experienced over the network. We tested multiple computers, multiple cables, multiple files. -
How can I check the data transfer rate of my FW800 port
I have an iMac 2.4 20 inch (MB323LL/A) with a Lacie external rugged hard drive (320 GB). I have attached it using my FW800 port with the cable supplied with the drive.
It seems slow to me so I was wondering if there is any way to see what the current data transfer is for a backup in progress. Of course it should be 800Mbps but is it really moving at that speed ? How can I tell what speed it is transferring at ? Can I use the same method for USB ports too ?When you move a large file, you are more likely to see a sustained transfer rate than a small file. Small files have to be individually read/write back and forth, thus slows the actual transfer rate down. If you are moving any file up to 4 GB and probably over 1 MB you'll see more realistic transfer rates. Furthermore your hard drive access time, and RPM figures into the equation too, as well as how much RAM you have. 800Mbps works out to 100 Megabytes per second under ideal conditions.
-
i have a brand new macbook pro that i was doing a data transfer via firewire from an old macbook, it got stopped/cable pulled out, now have spinning wheel of death that wont stop, how do i reboot/stop the wheel of death and start again? (this time il use time machine transfer)
Just power off the machine(s). Shut them down. Migration Assistant gets 'stuck' sometimes - best way to migrate really isn't over Firewire, though it will certainly work, but with both machines hardwired via Ethernet to the same router. You can use a TM backup, too, of course, provided that it's recent. Which is the best? Your choice. I've done it both ways and have a preference for MA, but TM restore can be a bit faster and less quarrelsome.
Clinton -
Candidate Data transfer from E-Recruiting System to HR system for New Hiring.
Hi All,
Hope everyone doing in good Spirit.
We are implementing E-Recruiting as Standalone for one of our client.
Can any please help me in regards with Data transfer from E-Rec System to HR System for hiring once the candidate has been successfully completed recruiting process.
You inputs are highly appreciable.
Thank you.
Sekhar.Hello Sekhar,
there are three different scenarios for transferring the data of an external candidate to the HR core for hiring.
the easiest and most commonly used is the RFC connection. When creating an activity of category data transfer the data of the candidate is transferred from eRec to HR core. There it is stored in table T752F. Then you can run transaction PA48. There you can select the candidate and run a hiring action. This is the same action like in PA40 only the system will preset the fields with the values from eRec (similar to batch input).
Instead of using the RFC solution you can transfer the data using PI (this can be activated using a switch in T77S0). To be honest none of my customers is using this. Either they had no PI server at all or they did not use it for eRec
The third was delivered with a business function HCM_HIRE_INT_CI_1. This is based on HCM processes and forms and targeted towards customers using Talent Management Core (e.g. data for education and work experience is transferred into the TM Core infotypes 740X as contrary to the hr core standard infotypes 0022 and 0023 they are structured like the eRec ones). Of course as you can do a lot of customer enhancements to HCMP&F you can replace the behavior nearly completely. One or two of my clients discussed this solution but as far as I know none is actually using it.
The simple truth is most customers seem to not use any integration at all. The first solution is easy to activate but only covers around 13 fields. Compared to a real full blow hiring action this is not even 10% of the fields which have to be entered. So the presetting this small number of fields is not a great help especially as you have to check every information anyways. Furthermore PA48 is not very nice and lacks functions to structure the incoming records which makes it difficult to handle in large distributed organizations.
The other two options require a lot of infrastructure for small functionality. What we discussed with a client was using the new hire integration to preset a full hiring form with eRec data and then send to the candidate as offline form to gather all missing information and use this for hiring. But there were to many issues on data privacy aspects when sending a form with social security data, bank account data, etc. via email. Furthermore they required actual signatures.
Kind regards
Roman -
Is there a place in my CS6 that will show the key so I can have Mac do a data transfer?
My college provided all design graduates with a Macbook with CS6 Illustrator, Photoshop, InDesign, Dreamweaver, Fireworks, Bridge, Extension manager, and Flash installed and registered with the key to Adobe. My laptop that they gave has gone bad and is being replaced this weekend by myself since my school won't fix it(per their contract they are required to so I plan to go after them for this but int he meantime) The school never provided us with the license key for this CS6, they did the install themselves, is there a place in my programs on my laptop that I can go to in order to get this key so I can have Mac do a data transfer?
Thanks, thats a good resource. However, it doesn't help in my situation, I didn't [urchase this or install it directly thru Adobe, as stated my college, College america(famous for their promotion that if you go to school with them and graduate you get a free laptop with all of CS6 included) this means they installed it as a mass install on all Design students laptops. They originally gave us CS5 then sent us a link to a site for upgrading to CS6, the email said this from the college;
Great News Regarding the Upgrade to CS6:
As it has been announced in your Design courses the free upgrade to CS6 is now available for all active Graphic Arts and Web Design students.
To get the upgrade please follow these 3 simple steps:
1- Copy and paste this link to your web browser: getmyisos.myvalcom.net
2- Select the download for your specific computer (Mac or HP)
It will take a long time to download, make sure you reset your “sleep” timer on your computer so it does not doze off during the download process. When it is complete…
When downloading the upgrade it (I guess, just speculating here) had the license bult in because it was never displayed it just downloaded and
i have used it ever since. I of course tried contacting the school for this but when you graduate from them, and are no longer a potential student they can suck up to sell you on their courses, they stop responding and being nice.
Does anyone have any other ideas? Is there a spot in the programs where if I open preferences in my Mac book or if I open he programs I can click something that displays the license in my laptop?
Thanks -
I recently purchased a MacBook Pro and transferred data from my MacBook using Migration Assistant via Ethernet cable. I was confused about consolidating my accounts, so I continued to use my old MacBook. Can I now update the data transfer using the same process and begin using my new MacBook Pro exclusively? How do I consolidate my existing accounts?
Thank you.Of course. It does everything it did before Yosemite. You just won't be able to send or receive SMS messages with it.
-
Copy data transfer routine.
13.01.2009
Hello Gurus,
How do we make a copy of data transfer routine ??? I dont find any copy option ??
Regards,There is sort of a trick you can use. In VOFM transaction, find the routine you wish to copy. Switch to Change mode (Ctrl-F1), then place the cursor in the field with the routine number and simply type the new routine number (e.g. 901) over the existing one. When you hit Enter, you'll be prompted to enter an access key to create a new routine.
Access key may be obtained on the SAP's website (if you have an authorization) or from your Basis admin, as mentioned above.
Copy/paste would also work, of course, after you have created a new, blank routine. -
970A-G43 / After reinstall windows7 I/O data transfer is low
Hi,
I reinstalled my Windows7 after a very long time of use. Even I did not reinstalled OS when I changed my mainboard for this MSI.
Now after a fresh install I cannot run any previously installed on a different Disk.
I have:
1 disk for OS (WD 320G)
1 disk for Games (WD 500G)
1 disk for Data (Seagate 2TB)
I tested data transfer from OS - Games Data disks and it is low or bad, even getting disconnected the disks sometimes.
I checked for corrupted sectors all the disks and all is fine.
It seems that every time that I want to play a game the files or folder needs to be read and then it will run fine, but at any new screen it needs to read again and that is very low again.
Any suggestion is welcome, even if I have to resinstall following some tips.
Thanks in advance.
BazcorQuote from: Bazcor on 15-December-13, 23:44:30
Hi,
I reinstalled my Windows7 after a very long time of use. Even I did not reinstalled OS when I changed my mainboard for this MSI.
Now after a fresh install I cannot run any previously installed on a different Disk.
I have:
1 disk for OS (WD 320G)
1 disk for Games (WD 500G)
1 disk for Data (Seagate 2TB)
I tested data transfer from OS - Games Data disks and it is low or bad, even getting disconnected the disks sometimes.
I checked for corrupted sectors all the disks and all is fine.
It seems that every time that I want to play a game the files or folder needs to be read and then it will run fine, but at any new screen it needs to read again and that is very low again.
Any suggestion is welcome, even if I have to resinstall following some tips.
Thanks in advance.
Bazcor
When you reinstall Windows from scratch you also need to reinstall your games/applications. Some older games will run fine from their self-contained directories without the need for re-installation, but some games won't run at all until they are re-installed. Of course, this may not be what you are talking about... -
How to find the max data transfer rate(disk speed) supported by mobo?
I plan on replacing my current HDD with a new and bigger HDD.
For this I need to know the max data transfer rate(disk speed) that my mobo will support. However, dmidecode is not telling me that. Am I missing something?
Here's dmidecode:
# dmidecode 2.11
SMBIOS 2.5 present.
80 structures occupying 2858 bytes.
Table at 0x000F0450.
Handle 0xDA00, DMI type 218, 101 bytes
OEM-specific Type
Header and Data:
DA 65 00 DA B2 00 17 4B 0E 38 00 00 80 00 80 01
00 02 80 02 80 01 00 00 A0 00 A0 01 00 58 00 58
00 01 00 59 00 59 00 01 00 75 01 75 01 01 00 76
01 76 01 01 00 05 80 05 80 01 00 D1 01 19 00 01
00 15 02 19 00 02 00 1B 00 19 00 03 00 19 00 19
00 00 00 4A 02 4A 02 01 00 0C 80 0C 80 01 00 FF
FF 00 00 00 00
Handle 0xDA01, DMI type 218, 35 bytes
OEM-specific Type
Header and Data:
DA 23 01 DA B2 00 17 4B 0E 38 00 10 F5 10 F5 00
00 11 F5 11 F5 00 00 12 F5 12 F5 00 00 FF FF 00
00 00 00
Handle 0x0000, DMI type 0, 24 bytes
BIOS Information
Vendor: Dell Inc.
Version: A17
Release Date: 04/06/2010
Address: 0xF0000
Runtime Size: 64 kB
ROM Size: 4096 kB
Characteristics:
PCI is supported
PNP is supported
APM is supported
BIOS is upgradeable
BIOS shadowing is allowed
ESCD support is available
Boot from CD is supported
Selectable boot is supported
EDD is supported
Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
3.5"/720 kB floppy services are supported (int 13h)
Print screen service is supported (int 5h)
8042 keyboard services are supported (int 9h)
Serial services are supported (int 14h)
Printer services are supported (int 17h)
ACPI is supported
USB legacy is supported
BIOS boot specification is supported
Function key-initiated network boot is supported
Targeted content distribution is supported
BIOS Revision: 17.0
Handle 0x0100, DMI type 1, 27 bytes
System Information
Manufacturer: Dell Inc.
Product Name: OptiPlex 755
Version: Not Specified
UUID: 44454C4C-5900-1050-8033-C4C04F434731
Wake-up Type: Power Switch
SKU Number: Not Specified
Family: Not Specified
Handle 0x0200, DMI type 2, 8 bytes
Base Board Information
Manufacturer: Dell Inc.
Product Name: 0PU052
Version:
Handle 0x0300, DMI type 3, 13 bytes
Chassis Information
Manufacturer: Dell Inc.
Type: Space-saving
Lock: Not Present
Version: Not Specified
Asset Tag:
Boot-up State: Safe
Power Supply State: Safe
Thermal State: Safe
Security Status: None
Handle 0x0400, DMI type 4, 40 bytes
Processor Information
Socket Designation: CPU
Type: Central Processor
Family: Xeon
Manufacturer: Intel
ID: 76 06 01 00 FF FB EB BF
Signature: Type 0, Family 6, Model 23, Stepping 6
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Not Specified
Voltage: 0.0 V
External Clock: 1333 MHz
Max Speed: 5200 MHz
Current Speed: 2666 MHz
Status: Populated, Enabled
Upgrade: Socket LGA775
L1 Cache Handle: 0x0700
L2 Cache Handle: 0x0701
L3 Cache Handle: Not Provided
Serial Number: Not Specified
Asset Tag: Not Specified
Part Number: Not Specified
Core Count: 2
Core Enabled: 2
Thread Count: 2
Characteristics:
64-bit capable
Handle 0x0700, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 32 kB
Maximum Size: 32 kB
Supported SRAM Types:
Other
Installed SRAM Type: Other
Speed: Unknown
Error Correction Type: None
System Type: Data
Associativity: 8-way Set-associative
Handle 0x0701, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 6144 kB
Maximum Size: 6144 kB
Supported SRAM Types:
Other
Installed SRAM Type: Other
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: <OUT OF SPEC>
Handle 0x0800, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PARALLEL
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-25 female
Port Type: Parallel Port PS/2
Handle 0x0801, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: SERIAL1
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-9 male
Port Type: Serial Port 16550A Compatible
Handle 0x0802, DMI type 126, 9 bytes
Inactive
Handle 0x0803, DMI type 126, 9 bytes
Inactive
Handle 0x0804, DMI type 126, 9 bytes
Inactive
Handle 0x0805, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB1
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0806, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB2
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0807, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB3
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0808, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB4
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0809, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB5
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB6
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB7
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB8
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: ENET
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: RJ-45
Port Type: Network Port
Handle 0x080E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: MIC
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x080F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: LINE-OUT
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0810, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: LINE-IN
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0811, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: HP-OUT
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0812, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: MONITOR
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-15 female
Port Type: Video Port
Handle 0x090A, DMI type 9, 13 bytes
System Slot Information
Designation: SLOT1
Type: x1 Proprietary
Current Usage: In Use
Length: Long
Characteristics:
PME signal is supported
Handle 0x0901, DMI type 126, 13 bytes
Inactive
Handle 0x0902, DMI type 9, 13 bytes
System Slot Information
Designation: SLOT2
Type: 32-bit PCI
Current Usage: Available
Length: Long
ID: 2
Characteristics:
5.0 V is provided
3.3 V is provided
PME signal is supported
Handle 0x0903, DMI type 126, 13 bytes
Inactive
Handle 0x0904, DMI type 126, 13 bytes
Inactive
Handle 0x0905, DMI type 126, 13 bytes
Inactive
Handle 0x0906, DMI type 126, 13 bytes
Inactive
Handle 0x0907, DMI type 126, 13 bytes
Inactive
Handle 0x0908, DMI type 126, 13 bytes
Inactive
Handle 0x0A00, DMI type 10, 6 bytes
On Board Device Information
Type: Video
Status: Disabled
Description: Intel Graphics Media Accelerator 950
Handle 0x0A02, DMI type 10, 6 bytes
On Board Device Information
Type: Ethernet
Status: Enabled
Description: Intel Gigabit Ethernet Controller
Handle 0x0A03, DMI type 10, 6 bytes
On Board Device Information
Type: Sound
Status: Enabled
Description: Intel(R) High Definition Audio Controller
Handle 0x0B00, DMI type 11, 5 bytes
OEM Strings
String 1: www.dell.com
Handle 0x0D00, DMI type 13, 22 bytes
BIOS Language Information
Language Description Format: Long
Installable Languages: 1
en|US|iso8859-1
Currently Installed Language: en|US|iso8859-1
Handle 0x0F00, DMI type 15, 29 bytes
System Event Log
Area Length: 2049 bytes
Header Start Offset: 0x0000
Header Length: 16 bytes
Data Start Offset: 0x0010
Access Method: Memory-mapped physical 32-bit address
Access Address: 0xFFF01000
Status: Valid, Not Full
Change Token: 0x00000018
Header Format: Type 1
Supported Log Type Descriptors: 3
Descriptor 1: POST error
Data Format 1: POST results bitmap
Descriptor 2: System limit exceeded
Data Format 2: System management
Descriptor 3: Log area reset/cleared
Data Format 3: None
Handle 0x1000, DMI type 16, 15 bytes
Physical Memory Array
Location: System Board Or Motherboard
Use: System Memory
Error Correction Type: None
Maximum Capacity: 8 GB
Error Information Handle: Not Provided
Number Of Devices: 4
Handle 0x1100, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_1
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Manufacturer: AD00000000000000
Handle 0x1101, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_3
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1102, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_2
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1103, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_4
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1300, DMI type 19, 15 bytes
Memory Array Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x000FDFFFFFF
Range Size: 4064 MB
Physical Array Handle: 0x1000
Partition Width: 1
Handle 0x1400, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Device Handle: 0x1100
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 1
Interleaved Data Depth: 1
Handle 0x1401, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00080000000
Ending Address: 0x000FDFFFFFF
Range Size: 2016 MB
Physical Device Handle: 0x1101
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 1
Interleaved Data Depth: 1
Handle 0x1402, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Device Handle: 0x1102
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 2
Interleaved Data Depth: 1
Handle 0x1403, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00080000000
Ending Address: 0x000FDFFFFFF
Range Size: 2016 MB
Physical Device Handle: 0x1103
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 2
Interleaved Data Depth: 1
Handle 0x1410, DMI type 126, 19 bytes
Inactive
Handle 0x1800, DMI type 24, 5 bytes
Hardware Security
Power-On Password Status: Enabled
Keyboard Password Status: Not Implemented
Administrator Password Status: Enabled
Front Panel Reset Status: Not Implemented
Handle 0x1900, DMI type 25, 9 bytes
System Power Controls
Next Scheduled Power-on: *-* 00:00:00
Handle 0x1B10, DMI type 27, 12 bytes
Cooling Device
Type: Fan
Status: OK
OEM-specific Information: 0x0000DD00
Handle 0x1B11, DMI type 27, 12 bytes
Cooling Device
Type: Fan
Status: OK
OEM-specific Information: 0x0000DD01
Handle 0x1B12, DMI type 126, 12 bytes
Inactive
Handle 0x1B13, DMI type 126, 12 bytes
Inactive
Handle 0x1B14, DMI type 126, 12 bytes
Inactive
Handle 0x2000, DMI type 32, 11 bytes
System Boot Information
Status: No errors detected
Handle 0x8100, DMI type 129, 8 bytes
OEM-specific Type
Header and Data:
81 08 00 81 01 01 02 01
Strings:
Intel_ASF
Intel_ASF_001
Handle 0x8200, DMI type 130, 20 bytes
OEM-specific Type
Header and Data:
82 14 00 82 24 41 4D 54 01 01 00 00 01 A5 0B 02
00 00 00 00
Handle 0x8300, DMI type 131, 64 bytes
OEM-specific Type
Header and Data:
83 40 00 83 14 00 00 00 00 00 C0 29 05 00 00 00
F8 00 4E 24 00 00 00 00 0D 00 00 00 02 00 03 00
19 04 14 00 01 00 01 02 C8 00 BD 10 00 00 00 00
00 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
Handle 0x8800, DMI type 136, 6 bytes
OEM-specific Type
Header and Data:
88 06 00 88 5A 5A
Handle 0xD000, DMI type 208, 10 bytes
OEM-specific Type
Header and Data:
D0 0A 00 D0 01 03 FE 00 11 02
Handle 0xD100, DMI type 209, 12 bytes
OEM-specific Type
Header and Data:
D1 0C 00 D1 78 03 07 03 04 0F 80 05
Handle 0xD200, DMI type 210, 12 bytes
OEM-specific Type
Header and Data:
D2 0C 00 D2 F8 03 04 03 06 80 04 05
Handle 0xD201, DMI type 126, 12 bytes
Inactive
Handle 0xD400, DMI type 212, 242 bytes
OEM-specific Type
Header and Data:
D4 F2 00 D4 70 00 71 00 00 10 2D 2E 42 00 11 FE
01 43 00 11 FE 00 0F 00 25 FC 00 10 00 25 FC 01
11 00 25 FC 02 12 00 25 FC 03 00 00 25 F3 00 00
00 25 F3 04 00 00 25 F3 08 00 00 25 F3 0C 07 00
23 8F 00 08 00 23 F3 00 09 00 23 F3 04 0A 00 23
F3 08 0B 00 23 8F 10 0C 00 23 8F 20 0E 00 23 8F
30 0D 00 23 8C 40 A6 00 23 8C 41 A7 00 23 8C 42
05 01 22 FD 02 06 01 22 FD 00 8C 00 22 FE 00 8D
00 22 FE 01 9B 00 25 3F 40 9C 00 25 3F 00 09 01
25 3F 80 A1 00 26 F3 00 A2 00 26 F3 08 A3 00 26
F3 04 9F 00 26 FD 02 A0 00 26 FD 00 9D 00 11 FB
04 9E 00 11 FB 00 54 01 23 7F 00 55 01 23 7F 80
5C 00 78 BF 40 5D 00 78 BF 00 04 80 78 F5 0A 01
A0 78 F5 00 93 00 7B 7F 80 94 00 7B 7F 00 8A 00
37 DF 20 8B 00 37 DF 00 03 C0 67 00 05 FF FF 00
00 00
Handle 0xD401, DMI type 212, 172 bytes
OEM-specific Type
Header and Data:
D4 AC 01 D4 70 00 71 00 03 40 59 6D 2D 00 59 FC
02 2E 00 59 FC 00 6E 00 59 FC 01 E0 01 59 FC 03
28 00 59 3F 00 29 00 59 3F 40 2A 00 59 3F 80 2B
00 5A 00 00 2C 00 5B 00 00 55 00 59 F3 00 6D 00
59 F3 04 8E 00 59 F3 08 8F 00 59 F3 00 00 00 55
FB 04 00 00 55 FB 00 23 00 55 7F 00 22 00 55 7F
80 F5 00 58 BF 40 F6 00 58 BF 00 EB 00 55 FE 00
EA 00 55 FE 01 40 01 54 EF 00 41 01 54 EF 10 ED
00 54 F7 00 F0 00 54 F7 08 4A 01 53 DF 00 4B 01
53 DF 20 4C 01 53 7F 00 4D 01 53 7F 80 68 01 56
BF 00 69 01 56 BF 40 FF FF 00 00 00
Handle 0xD402, DMI type 212, 152 bytes
OEM-specific Type
Header and Data:
D4 98 02 D4 70 00 71 00 00 10 2D 2E 2D 01 21 FE
01 2E 01 21 FE 00 97 00 22 FB 00 98 00 22 FB 04
90 00 11 CF 00 91 00 11 CF 20 92 00 11 CF 10 E2
00 27 7F 00 E3 00 27 7F 80 E4 00 27 BF 00 E5 00
27 BF 40 D1 00 22 7F 80 D2 00 22 7F 00 45 01 22
BF 40 44 01 22 BF 00 36 01 21 F1 06 37 01 21 F1
02 38 01 21 F1 00 39 01 21 F1 04 2B 01 11 7F 80
2C 01 11 7F 00 4E 01 65 CF 00 4F 01 65 CF 10 D4
01 65 F3 00 D5 01 65 F3 04 D2 01 65 FC 00 D3 01
65 FC 01 FF FF 00 00 00
Handle 0xD403, DMI type 212, 157 bytes
OEM-specific Type
Header and Data:
D4 9D 03 D4 70 00 71 00 03 40 59 6D 17 01 52 FE
00 18 01 52 FE 01 19 01 52 FB 00 1A 01 52 FB 04
1B 01 52 FD 00 1C 01 52 FD 02 1D 01 52 F7 00 1E
01 52 F7 08 1F 01 52 EF 00 20 01 52 EF 10 21 01
52 BF 00 22 01 52 BF 40 87 00 59 DF 20 88 00 59
DF 00 E8 01 66 FD 00 E9 01 66 FD 02 02 02 53 BF
00 03 02 53 BF 40 04 02 53 EF 00 05 02 53 EF 10
06 02 66 DF 00 07 02 66 DF 20 08 02 66 EF 00 09
02 66 EF 10 17 02 66 F7 00 18 02 66 F7 08 44 02
52 BF 40 45 02 52 BF 00 FF FF 00 00 00
Handle 0xD800, DMI type 126, 9 bytes
Inactive
Handle 0xDD00, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 00 DD 00 01 00 00 00 10 F5 00 00 00 00 00
00 00 00
Handle 0xDD01, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 01 DD 00 01 00 00 00 11 F5 00 00 00 00 00
00 00 00
Handle 0xDD02, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 02 DD 00 01 00 00 00 12 F5 00 00 00 00 00
00 00 00
Handle 0xDE00, DMI type 222, 16 bytes
OEM-specific Type
Header and Data:
DE 10 00 DE C1 0B 00 00 10 05 19 21 01 00 00 01
Handle 0x7F00, DMI type 127, 4 bytes
End Of Table
Hdparm also does not tell me the max data transfer rate (disk speed) of my current drive although this link : www.wdc.com/en/library/sata/2879-001146.pdf says that it is 3.0Gb/s
and here's hdparm -I /dev/sda
/dev/sda:
ATA device, with non-removable media
Model Number: WDC WD800JD-75JNC0
Firmware Revision: 06.01C06
Standards:
Supported: 6 5 4
Likely used: 8
Configuration:
Logical max current
cylinders 16383 16383
heads 16 16
sectors/track 63 63
CHS current addressable sectors: 16514064
LBA user addressable sectors: 156250000
Logical/Physical Sector size: 512 bytes
device size with M = 1024*1024: 76293 MBytes
device size with M = 1000*1000: 80000 MBytes (80 GB)
cache/buffer size = 8192 KBytes
Capabilities:
LBA, IORDY(can be disabled)
Standby timer values: spec'd by Standard, with device specific minimum
R/W multiple sector transfer: Max = 16 Current = 8
Recommended acoustic management value: 128, current value: 254
DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 *udma5
Cycle time: min=120ns recommended=120ns
PIO: pio0 pio1 pio2 pio3 pio4
Cycle time: no flow control=120ns IORDY flow control=120ns
Commands/features:
Enabled Supported:
* SMART feature set
Security Mode feature set
* Power Management feature set
* Write cache
* Look-ahead
* Host Protected Area feature set
* WRITE_BUFFER command
* READ_BUFFER command
* DOWNLOAD_MICROCODE
SET_MAX security extension
Automatic Acoustic Management feature set
* Device Configuration Overlay feature set
* Mandatory FLUSH_CACHE
* SMART error logging
* SMART self-test
* Gen1 signaling speed (1.5Gb/s)
* Host-initiated interface power management
* SMART Command Transport (SCT) feature set
* SCT Long Sector Access (AC1)
* SCT LBA Segment Access (AC2)
* SCT Error Recovery Control (AC3)
* SCT Features Control (AC4)
* SCT Data Tables (AC5)
Security:
Master password revision code = 65534
supported
not enabled
not locked
frozen
not expired: security count
not supported: enhanced erase
Checksum: correct
Last edited by Inxsible (2011-03-27 04:40:49)I just checked my BIOS and my current setting is set at IDE although it also mentions that the default should be AHCI. Currently I have a dual boot of Windows 7 (need it for Tax software) and Arch
So I guess, when I get the new HDD, I will first set it to AHCI and then install the OSes on it. See if NCQ helps any, and if not I will turn it back and re-install (if I have to). I am planning to have Windows only in virtualbox in the new drive.
Anyhoo, while I was in the BIOS I found two things which I had questions about :
1) Under Onboard Devices --> Integrated NIC , my setting is currently set at "On w/PXE" and it says the default should be just "On". Would it be ok to change it back to On since its a single machine and its not booting an OS on any server. I just don't want to have to re-install anything now since I will be doing that in the new HDD.
2) How would I know whether my BIOS would support a 64 bit OS in Virtualbox? I checked some setting under Virtualization, but they weren't very clear.
I will edit this post and let you know exactly what settings were present under the Virtualization sub-section. -
ISSUE:regarding production version tab of MRP4 of data transfer using BD10
Hi all,
This is regarding production version tab of MRP4 of data transfer using ALE idoc (BD10).
When i transfer the data using BD10 the production version is received at receiving end through segment
but not created in MRP4 view tab.An error is coming as-
"You wanted to maintain the master record of the material AB_06.04.09(2). However, it is already being processed by the user EBGABAP and is therefore locked."
I logged in as-EBGABAP
Please help me resolve the issue.
Thanks
Edited by: sanu debu on May 6, 2009 11:08 AM
Edited by: sanu debu on May 6, 2009 11:09 AM
Edited by: sanu debu on May 6, 2009 11:11 AM>
sanu debu wrote:
> Hi,
> I have to upload production version tab data of MRP4 view(MM01).Please suggest a function moduleor bapi for the same.
>
> Thanks.
>
> Edited by: sanu debu on May 6, 2009 3:24 PM
BAPI_MATERIAL_SAVEDATA can be used, populate the respective fields in input parameter PLANTDATA -
Issues with data transfer / connectivi​ty
Hi,
I bought a Curve 8320 last week and activated BIS. The issue that I am facing is:
- Mails do not get delivered and connectivity to the internet is lost even though the data signal (EDGE) is available. I can see an upload arrow flashing on the right top corner
- What I have noticed is that the connectivity gets resumed when I do any of the following:
a. Switch on WiFi (immediately the data connection starts receiving and sending messages and internet connectivity is resumed). Even after switching off the WiFi, it works fine
b. Switch off the device and restart
Can someone help me? Please let me know if you need any more details.
ThanksYou can try using FExplorer and using it to delete the file C:\system\shareddata\101ff93b.ini from the phone. It should reset the Data Transfer app.
FExplorer you can find here:
http://www.gosymbian.com -
Init w/o data transfer shows Added/Transfrd - 1/1
Hi ,
Init w/o data transfer load was successful after having applied <i>Note 689964 - ODS object: Switching from a full to delta upload !</i>
I have two weird ( nt sure ) issues below :
<b>Issue 1</b>
On Manage screen I see Added - 1 & Transferred - 1, however I dont see this record in the DSO ( Display data ).
Why is that so ?
<b>
Issue 2</b>
All seems green excepting when I go check the Details Tab - I see some reds
DataStore Activation (Change Log) : Errors occurred
No data targets selected for update. Action terminated.
InfoPackage ZPAK_*** could not be started by Bapi_ipak_start
Errors in InfoPackage check for DataStore 0CCA_O09 ; no update possible
Please comment SDNer'sDear Jr.Roberto,
Issue 1
On Manage screen I see Added - 1 & Transferred - 1, however I dont see this record in the DSO ( Display data ).
Why is that so ?
<b>
--> When you do a init with out data transfer, system transfers one record that is not corresponding to the data, but is a control record corresponding to the init selections.</b>
Issue 2
All seems green excepting when I go check the Details Tab - I see some reds
DataStore Activation (Change Log) : Errors occurred
No data targets selected for update. Action terminated.
InfoPackage ZPAK_*** could not be started by Bapi_ipak_start
Errors in InfoPackage check for DataStore 0CCA_O09 ; no update possible
<b>---> It is because you dont have a active update rules maintained for the infosource to the data target, or you have not selected any data target in the infopackage , it can also be the case that the infopackage which generates a program to start the load is having some errors, if possbile create another infopackage and start the load with active Update rules to data target.</b>
Cheers!!!!
Charan
Message was edited by:
Sri Krishna Charan Viswanatha -
Hello Everyone,
I have a new 2TB Time Capsule running with a MacBook Air. I want to use the TC to access data (Aperture library, iTunes library, other Files) and to backup my MacBook Air via Time Machine. I set it up, integrated the TC in my Network (FritzBox) by choosing "extend existing network" and it works. BUT only with 1.1Mbit/second while writing or reading Data to/from it. Internet speed is very good, like it was before. While the 1.1Mbit/second seem to be ok with Aperture and iTunes (streaming music and movies) it is still painfully slow and I'm not realy happy with that
I've read that:
The 1.1Mbit problem is pretty common when Time Capsule is integrated and used to extend a network (bridge modus), it also looses all ethernet connectivity then (that woul explain why connecting it by ethernet didn't help during initial setup and data transfer)
Is there a solution besides ditching the Fritzbox and using the TC to build the network? Because basicly I still need the Fritzbox for its DECT features.
Thank you for any help in advance and have a nice day,
OlliYou have double hop wireless with this setup..
You should bridge the TC.. that is router bridge not wireless bridge, and plug the TC into the Frizyboy by ethernet.
Then you can setup the TC wireless to reinforce the fritzy..
Same wireless name as SSID.
Same security settings... really should be WPA2 AES or in TC personal.
Same password..
Just different wireless channel.
Then you can use 5ghz on the TC if you are up close and personal. -
Data transfer b/w SAP to Java using IDOC and Interface SAP Jco
Dear Experts,
The challenging requirement we are having is, we need to create the interface for data transfer between SAP system and the Java system. The data will be transferred from SAP to java and similarly once some processing done in Java again the details needs to be transferred from Java to SAP.
For this data transferred we are planning to use IDOC process and for interface "SAP Java connector (Version 3.0.5)" we are planning to use. As per our understanding, from Java side one program needs to be written to connect with SAP as "Registered program". This registered program will appear in SAP GATEWAY automatically and using tRFC, TCP/IP connection both SAP and Java system will be connected.
In this case we are having some doubts.
1. The data from SAP is going to be transfered from one Custom transaction (Z tcode). Once "Outbound IDOC" will get triggered and will carry the details. Now the doubt is, whether the data / details will get transfered to JAVA system automatically or we need to perform any other steps from SAP ABAP coding...(like converting in to flat file, XML file and etc) ??
2. We are planning to install "SAP Jco" in Java server. Is this correct...??
3. Other than SAP Jco any other softwares needs to be installed or not..??
4. Since we are going to trigger the "outbound IDOC" from custom transaction, we are planning to develope one program in SE37. Other than this any other program we need to develop or not..??
5. Any sample Java program for the SAP Jco version 3.0.5 to create the "Registered program" with SAP..? (e.g. SAP Listener program).?
If anybody has detailed steps or explanation please share it with us.
Thanks in advance
Warm Regards,
VELHi All,
For the above mentioned issue, we implemented JCo software in JAVA system and created the JAVA program including SAP logon credential details like Client, User name, password and Language details.
When this JAVA program was compiled successfully then, that non SAP system will appear in SAP gateway Tcode.
Once non SAP system started appearing in SAP gateway that means, both SAP & Non SAP are connected automatically.
Regards,
Velmurugan P
Maybe you are looking for
-
Hi, When is the 122 movement type used and when is the 161 movement type used in the return to vendor process. Thanks GS
-
A DATA_BUFFER_EXCEEDED viewing data on a large table
Hello, Am getting error below while fetching data in DS designer from SAP ECC Tables. Error calling RFC function to get table data: <RFC_ABAP_EXCEPTION-(Exception_Key: DATA_BUFFER_EXCEEDED, SY-MSGTY: E, SY-MSGID: I followed the KBA : 1752954 - DATA_
-
Portal web dynpro form link as email .
Dear All The requirement goes like this: We are developing a form in web dynpro and integerating into portal as an iview. Whenever the user submits a new form we should send a link of the form in portal to the user as email (with some parameters like
-
SYS_REFCURSOR output problem
create or replace procedure p1 (p1 out SYS_REFCURSOR) as sqlstmt VARCHAR2(32760); begin sqlstmt :='WITH cte AS (SELECT Count(OBJECT_ID) from all_objects where OBJECT_ID <515) Select * from cte' ; dbms_output.put_line(sqlstmt); OPEN p1 FO
-
hi all! ...newbee... after a long way i was able to make a multi instrument. i use lets say audio instr. 1 as an exs24 sampler from c1 to lets say c4 with a bass sound. its easy to make an exs24 instrument sound at a specific range. the second audio