Data transfer form 4.7 to ECC 6.0 in upgradation project. How to do?
Hi Experts,
The client is going for an up-gradation from 4.7 to ECC 6.0. The entire data needs to be transferred from 4.7 to ECC 6.0. What is the best possible way to do this?
Please advise.
Regards,
Tomesh
Hi ,
Going for an up-gradation from 4.7 to ECC 6.0. The data needs gets migrated from 4.7 to ECC 6.0.
SAP normally has defined better SAP functionalities in the new system .
In any upgrade project use Tcode SPDD. In this all the dictionary objects u2013 data elements, database tables and structures in the version 4.7 are compared with the upcoming new system.
All you need to do is the check whether the new change is suitable or not.You can make the modifications and then you need to make the migration of data, which can be automate.
the links for your reference.
Link:[https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/304b9de6-f84f-2b10-94af-e5ff7461c18c]
link:[http://solutionbrowser.erp.sap.fmpmedia.com/Default.aspx]
Thanks & Regards,
link:[Lakshmi Narayana]
Similar Messages
-
New Hire Data Transfer from E-Rec to ECC via PA48
Hi,
We have requirement where we need to use the basic new hire data transfer from erec to ecc using PA48.
Could someone help me by listing the step by step process that is required to configure in both EREC & ECC?
I know there is pdf document available online but that refers mostly to XI which we are not planning to use.
Please help.
Regards,
VikramHi,
For integration between E-Rec and ECC, check [Link|http://help.sap.com/saphelp_erp2005/helpdata/en/45/8150635e9c40c1e10000000a1553f7/frameset.htm]
This gives detailed information on synchronous and asynchronous data transfers between E-Rec and ECC.
Hope it helps!
Arpita -
I have to re-enter my Aperture license number and upgrade number every time I open Aperture after buying a new MacBook Pro and paying for the data transfer to be done at the Apple store. I can understand having to do this the first time but not every time. How can I get the license number saved?
Aperture 3.4.3 update specifically claims to fix the serial number problem. See the Release notes.
If you've already done the update and still have the problem, read this forum post about the same topic and a solution. -
Data transfer form cProject 3.1 to cProject 4.5
Hello Gurus,
I would know how transfer the data from cproject 3.1 to cproject 4.5.
I try to explain better:
I have an ECC 6.0 where I upgrade R3 ( from 4.7 to ECC6.0),
on another server 4.7 there is a cProject , the client would have the cProject ( also 3.1) on
only machine 6.0 ( where there is already R3..).
So
I should install the add on for cproject Suite on ECC 6.0 (tcode saint ) = The client has a new release (4.5) without add charge..
so I should:
1. move customizing ( Delivery Customizing is imported into client 000 and may need to be
copied to other clients. For more information, see Note 337623) ok,
2. BSP ? ( I think to update manually... is there another way?)
finally
3. I should transfer the data : How Can I do ? Is There any way to do this? ( with Saint, the system
allows me transfer the data? )
Thanks in advance
Ciaoodone
-
How do I get my iMac to communicate with my mouse. It keeps saying "wireless connection not discoverable". Thanks
Hey Jeanette
If you have a USB mouse handy, you can plug it in and use it to navigate to the Bluetooth settings in System Preferences to get the mouse to pair again. There are also troubleshooting steps in the article below for getting the mouse to pair as well.
Troubleshooting wireless mouse and keyboard issues
http://support.apple.com/kb/TS3048
Thanks for using Apple Support Communities.
Regards,
-Norm G. -
HR data transfer toolkit_ SAP Best practice
Hi All,
I got to know the New toolkit for HR Data Transfer in which SAP has provided the Built in Excel sheets for the certain Infotypes..I got the document through online. But am not able to use the transactions ..can any one help me out ..from where do i download the HR Data transfer toolkit and if any patches which i have install in the system.
Can you please help me out in giving me the Links.or steps from where do i donwload the toolkit.
Advance thanks for the help.
Regards
RajeshwarRajesh,
You have to request basis to apply the sar file that is specified in best business practise documentation.
Also note that data transfer tool for ECC 6.0 is different from ECC 5.0 or R/3.
The data transfer tool is now (in ECC 6) shifted to LSMW.
regards
Sridhar -
E-Rec: XI for data transfer
Hello Experts,
I am working on an implementation project where SAP E-Rec is on different box. We are on EhP5. We have XI for data transfer between both the systems (ECC and E-Rec). Now, when we use RFC to connect these systems, we use PA48 in ECC to hire candidates as employees which in turn pulls data from T752F table. Now as we are using XI, how/where does data flow?
Also, please guide in case candidate is a rehire, how and where to capture his previous perr number to validate candidate is actually an old employee? Instead of T752F, which table is populated which creates an entry in HR admin's UWL. Please help understand.
Thanks and regards,
E-Rec Beginner!Hello,
Please have a look at the attachment of note 997181 where the HR integration process is explained.
Regards
Nicole -
Rp-pppoe connected but no data transfer
hi,
i installed arch on 27th . Post installation i setup internet connection using rp-pppoe, which was a straight forward setup. I also got connected to net and downloaded data upon a system upgrade. Except this one instance, thereafter last two days if connected i am getting no data transfer after a connection is established.
Upon ping of 8.8.8.8 i am getting this error of destination net unreachable & if you ping google.com i get the error unknown host.
when i checked the pppoe status i get this message:
link is up and running on interface ppp0 and no packet errors both RX and TX.
The system upgrade did not happen on 27th due to the TZselec tconflicting files error.
It is a fresh system.
i am pasting below the lines from the messages.log of 27th when i got the data transfer happened for the first time and next of 29th with the same system but nothing happening except i am connected.
27th:
Jun 27 12:46:03 localhost kernel: [ 117.794497] r8169 0000:02:00.0: eth0: link up
Jun 27 12:46:06 localhost kernel: [ 120.763326] eth0: no IPv6 routers present
Jun 27 12:58:01 localhost kernel: [ 835.641169] PPP generic driver version 2.4.2
Jun 27 12:58:01 localhost pppd[888]: pppd 2.4.5 started by root, uid 0
Jun 27 12:58:01 localhost pppd[888]: Using interface ppp0
Jun 27 12:58:01 localhost pppd[888]: Connect: ppp0 <--> /dev/pts/0
Jun 27 12:58:02 localhost pppoe[889]: PADS: Service-Name: ''
Jun 27 12:58:02 localhost pppoe[889]: PPP session is 14295 (0x37d7)
Jun 27 12:58:02 localhost pppd[888]: CHAP authentication succeeded: CHAP authentication success, unit 7436
Jun 27 12:58:02 localhost pppd[888]: CHAP authentication succeeded
Jun 27 12:58:02 localhost kernel: [ 837.068606] PPP BSD Compression module registered
Jun 27 12:58:03 localhost pppd[888]: Cannot determine ethernet address for proxy ARP
Jun 27 12:58:03 localhost pppd[888]: local IP address 117.204.173.123
Jun 27 12:58:03 localhost pppd[888]: remote IP address 117.204.160.1
Jun 27 12:58:03 localhost pppd[888]: primary DNS address 218.248.255.212
Jun 27 12:58:03 localhost pppd[888]: secondary DNS address 218.248.241.2
Jun 27 13:01:01 localhost /USR/SBIN/CROND[934]: (root) CMD (run-parts /etc/cron.hourly)
Jun 27 13:01:01 localhost anacron[938]: Anacron started on 2012-06-27
Jun 27 13:01:01 localhost anacron[938]: Will run job `cron.daily' in 28 min.
Jun 27 13:01:01 localhost anacron[938]: Will run job `cron.weekly' in 48 min.
Jun 27 13:01:01 localhost anacron[938]: Will run job `cron.monthly' in 68 min.
Jun 27 13:01:01 localhost anacron[938]: Jobs will be executed sequentially
Jun 27 13:04:10 localhost -- MARK --
Jun 27 13:16:48 localhost pppoe-stop: Killing pppd
Jun 27 13:16:48 localhost pppd[888]: Terminating on signal 15
Jun 27 13:16:48 localhost pppd[888]: Connect time 18.8 minutes.
Jun 27 13:16:48 localhost pppd[888]: Sent 411268 bytes, received 16885685 bytes.
29th :
Jun 29 17:54:13 localhost kernel: [ 5.019108] r8169 0000:02:00.0: eth0: link down
Jun 29 17:54:14 localhost dhcpcd[675]: eth0: carrier acquired
Jun 29 17:54:14 localhost kernel: [ 6.632983] r8169 0000:02:00.0: eth0: link up
Jun 29 17:54:14 localhost dhcpcd[675]: eth0: broadcasting for a lease
Jun 29 17:54:15 localhost dhcpcd[675]: eth0: offered 192.168.1.2 from 192.168.1.1
Jun 29 17:54:15 localhost dhcpcd[675]: eth0: acknowledged 192.168.1.2 from 192.168.1.1
Jun 29 17:54:15 localhost dhcpcd[675]: eth0: checking for 192.168.1.2
Jun 29 17:54:21 localhost dhcpcd[675]: eth0: leased 192.168.1.2 for 10080 seconds
Jun 29 17:54:21 localhost dhcpcd[675]: forked to background, child pid 702
Jun 29 17:54:21 localhost /usr/sbin/crond[751]: (CRON) STARTUP (1.4.8)
Jun 29 17:54:21 localhost /usr/sbin/crond[751]: (CRON) INFO (Syslog will be used instead of sendmail.): No such file or directory
Jun 29 17:54:21 localhost /usr/sbin/crond[751]: (CRON) INFO (running with inotify support)
Jun 29 17:54:47 localhost kernel: [ 39.424170] NET: Registered protocol family 10
Jun 29 17:54:47 localhost kernel: [ 39.441086] NET: Registered protocol family 4
Jun 29 17:54:47 localhost kernel: [ 39.458946] NET: Registered protocol family 5
Jun 29 17:54:47 localhost kernel: [ 39.480053] PPP generic driver version 2.4.2
Jun 29 17:54:47 localhost pppd[811]: pppd 2.4.5 started by root, uid 0
Jun 29 17:54:47 localhost pppd[811]: Using interface ppp0
Jun 29 17:54:47 localhost pppd[811]: Connect: ppp0 <--> /dev/pts/0
Jun 29 17:54:48 localhost pppoe[812]: PADS: Service-Name: ''
Jun 29 17:54:48 localhost pppoe[812]: PPP session is 2021 (0x7e5)
Jun 29 17:54:48 localhost pppd[811]: CHAP authentication succeeded: CHAP authentication success, unit 4257
Jun 29 17:54:48 localhost pppd[811]: CHAP authentication succeeded
Jun 29 17:54:48 localhost kernel: [ 40.866233] PPP BSD Compression module registered
Jun 29 17:54:48 localhost pppd[811]: not replacing existing default route via 192.168.1.1
Jun 29 17:54:48 localhost pppd[811]: Cannot determine ethernet address for proxy ARP
Jun 29 17:54:48 localhost pppd[811]: local IP address 117.204.161.173
Jun 29 17:54:48 localhost pppd[811]: remote IP address 117.204.160.1
Jun 29 17:54:48 localhost pppd[811]: primary DNS address 218.248.255.212
Jun 29 17:54:48 localhost pppd[811]: secondary DNS address 218.248.241.2
Jun 29 17:54:57 localhost kernel: [ 49.523342] eth0: no IPv6 routers present
Jun 29 18:01:01 localhost /USR/SBIN/CROND[876]: (root) CMD (run-parts /etc/cron.hourly)
Jun 29 18:01:01 localhost anacron[881]: Anacron started on 2012-06-29
Jun 29 18:01:01 localhost anacron[881]: Will run job `cron.daily' in 29 min.
Jun 29 18:01:01 localhost anacron[881]: Will run job `cron.weekly' in 49 min.
Jun 29 18:01:01 localhost anacron[881]: Will run job `cron.monthly' in 69 min.
Jun 29 18:01:01 localhost anacron[881]: Jobs will be executed sequentially
Jun 29 18:04:04 localhost pppoe-stop: Killing pppd
Jun 29 18:04:04 localhost pppd[811]: Terminating on signal 15
Jun 29 18:04:04 localhost pppd[811]: Connect time 9.3 minutes.
Jun 29 18:04:04 localhost pppd[811]: Sent 0 bytes, received 926 bytes.
Now in both the cases i got connected but as i said before except twice on 27th i am not able to have data transfer of any type either through ping or pacman upgrade.
Upon the same time i cross checked on my other systems, ubuntu and windows and i had no problems with the same, to confirm any issue with my isp. As of now i am typing one of those systems only.
I have googled a lot, read the other options of pppd,etc, but upon similar queries by other users found no viable solution to this problem.
My hostname is also proper in the config files. I also once used static ip for a change to see if things go working
but nothing is sucessful so far.
The only viable solution i read so far upon google search where there was a success was a fresh installation of arch by an user and he got the same working. But definitely i wont go with that. As i said above i got connected twice on the day of the installation and post that also i am now getting connected but with no data transfer.
Pls suggest what to do to get the connection working.
regardsUpon a search on the forums yesterday
i read one user query on this forums who was advised the same and he had the same problem like me and it did not got solved with either methodds.
Last his query was still open. I did not save that link.
So i did not give that method a try so far, waiting for a solution for this method without going for new developments thinking a search for a day or two might get some viable results.
i guess you are mentioning the topic of this link
https://wiki.archlinux.org/index.php/Pppd [This article explains how to set up a point-ti-point connections using pppd and the kernel PPPoE driver. ]
Further in my case the connection is happening and also getting disconnected. You can very well see the same in the log file which i pasted.
Jun 27 13:16:48 localhost pppd[888]: Connect time 18.8 minutes.
Jun 27 13:16:48 localhost pppd[888]: Sent 411268 bytes, received 16885685 bytes.
Jun 29 18:04:04 localhost pppd[811]: Connect time 9.3 minutes.
Jun 29 18:04:04 localhost pppd[811]: Sent 0 bytes, received 926 bytes.
So same thing but different results on 2 different days. So what the problem really is i dont understand. Infact what the problem is the system is also not giving out, except that a connection happens, no data transfer takes place and the connection is cut and the stats are also show. Just diving to implement some new method or a reinstall, without resolving this which looks sensible yet senseless too, simply does not appeal here. If really there is some bug or issue with that rp-pppoe package then there is some point to jump to another method.
This must be solvable some way or other.
Last edited by beopen (2012-06-29 17:30:16) -
Data Transfer Toolbox for ECC 6.0
I am on ECC 6.0 and I am trying to install the data transfer toolbox (DTT) for HCM. I installed the ERP05V4.SAR file (which is in the 600-ERP-DATA folder), but there are no DTT tcodes. A colleague of mine told me he has used this in earlier versions of SAP (ECC 5.0) and he installed BPERPVD.SAR (which is in the 500-ERP-DATA folder) and the DTT was installed. So it seems that this does not exist for ECC 6.0, but we need it so I am looking for help!
I downloaded all of these files from OSS-downloads-SAP installations and upgrades-Enter by application group-SAP best practices-Best practices for my SAP all in one-SAP BP for HCM-HCM V1.500-installation.
Thanks
MikeHi Michael,
Were you able to get DTT installed for ECC 6.0? We are also, in the similar situation, trying to get DTT loaded in ECC 6.0.
Thanks. -
LBBIL_INVOICE. Billing Data: Transfer Structure to Smart Forms
Hi...
Can u please help me out in my query regading how the data passes to
LBBIL_INVOICE. Billing Data: Transfer Structure to Smart Forms.
I have an smartform which runs through VF01/VF02/ VF03 while pressing the print preview button.
But if i try to run it directly from driver program, no data wil be displayed. Now i have the requirement to detach from VF03.. and make it to run directly from my driver program.
what shall i have to do to achieve this. Should i have to take all the internal tables saparately or else can i use LBBIL_invoice structure itself.
If i can use that structure itself, how to make the data flow into it. Pls help me.
In my codeing these includes were there. is there anything related , is the data passes because of these includes
INCLUDE rlb_invoice_data_declare.
definition of forms
INCLUDE rlb_invoice_form01.
INCLUDE rlb_print_forms.
Pls clarify my dobut...
Thanks in advance,
Hema1. These are normal structure
2. you can use anywhere but they designed for forms currently.
3. Yes ,it works like it will look at NAST Table -> nast table will connect the TNAPR Table -> tnapr will have smart form print program.
so smart form program calls smartform and it will show output
4. you can create your own structure and use them into anywhere like report program or forms..
5. you can see example simple form name SF_EXAMPLE_01 ,program name is SF_EXAMPLE_01 ,you can design your own form and print program.
Thanks
Seshu -
Hi all,
We are using having 2 backend systems 1 for HR other than Erec and another one for erec.
Now we have setup the ALE data transfer using Message type HRMD_ABA.
In erec we have only ERECRUIT Component deployed in backend,no EA HR or SAP HR component deployed.
MEaning no PA* tables.
Now when Transfer personnel number(HR!001-A008 with Position) to erec box,it says no pernr exist.
Howver i cannot tranfer the pernr from ECC to Erec as we dont have PA* tables in Erec.
Can you share me the object types that are transferred from ECC to EREc and EREC and ECC.
What are the components to be deployed in backend Erec box.
In Portal for requistions application which should backend(System Object) and for recruiter and recruitment admin applications which should be the backend system(System Object).
Thanks,
NachyHi,
Check the link :
http://help.sap.com/saphelp_erp2005/helpdata/en/45/8150635e9c40c1e10000000a1553f7/frameset.htm
Supported infotypes for transfering data from the E-Recruiting to the HR-System are the PA infotypes 0,1,2 and 6. There are 15 fields sent to pa48 if they were filled in the E-Recruiting system, which are
- forename, initials, surname
- gender
- birth date
- correspondance language
- address (street, city, streetcode, region, country)
- hiring date
- organisation unit
- position
- personel number (for internal candidates)
So these are the infotypes which can be transfered automatically and cause no problems. If you want the "title" to be transferred additionally, you have to adjust the system behaviour accordingly.
To set up data transfer,
In E-Rec System, use Tcode - BD64 Partner Type LS - Generate partner profile for the ECC System
Use Tcode - WE20 for the Partner profiles checking
For ECC Partner Profile, Give Outbound parameters - Messahge type HRMD_ABA and SYNCH. Give Inbound parameters- Message Type HRMD_ABA
In ECC system, use BD64 for the Partner Type LS. Partner Type LS - Generate partner profile for theCreate Erec System(
Use Tcode - WE20 for the Partner profiles checking
For E-Rec Partner Profile , Give Outbound parameters - Messahge type HRMD_ABA and SYNCH. Give Inbound parameters- Message Type HRMD_ABA
After doing data transfer using RHALEINI, use transaction SM58 to check whether the data has been transferred or not.
Hope it helps!
Arpita -
OM and PA data transfer from SAP 4.7 to ECC 6.0
Dear Experts,
hi
i am working on one project where i will need to design the data transfer from SAP 4.7 to ECC 6.0. this is not a upgrade project.
the data of PA and OM are in 4.7 which is existing system. i need to transfer entire data into ECC 6.0 so i can use that data for my E-Recruitment module ( we are doing E-rec fresh implementation.)
we will keep both the systems (4.7 and ECC 6.0). ECC 6.0 will be used for E-Rec and OM only. for PA and Payroll we will use 4.7.
can some one tell me,
1. what are the key points to keep in consideration from OM point of view ?
2. which is the best method to transfer the OM structure and data from 4.7 to ECC?
3. what are the risks?
4. which system we should make master system and which will be the slave system? why ?
your input will be much appreciated.
thanks and regards
chandraHi Chandra,
I was under the impression that you are planning to use PA & OM from 4.7, now I read it again.
Now its advisable to keep ECC 6 as a master system, becoz OM is the stating point of the HR processes where all Orgnization unit, job, position exists. Later the same data can flow to the slave system for PA use. As OM is the starting point, this system should be the master system.
Abou the IDoc interface.
Check the basic type HRMS_A05, whether it has all the data you need to transmit. T-Code WE30
If you need to add something you can create a Z version in WE31. I selected HRMS_A05 as it is present in both the SAP version.
Next there are series of transaction you need to process. Check with technical person who hands IDoc interafcing.
Steps are:
Assigning Message type to IDOC Type with extension. T-Code WE82
Create Logical System:
T-Code SALE-> Basic Settings-> Logical Systems-> Define Logical System
It is required to configure in the sending system as well as in the receiving system
Assign Logical System to Client:
T-Code SALE-> Basic Settings-> Logical Systems-> Assign Logical System to Client
Create RFC Destinations:
T-Code SM59, select ABAP connection of type 3.
Create Distribution Model: T-Code BD64
Generate Partner Profile: T-Code BD82
Maintain sending system partner profile: T-Code WE20
Link Message Type to Function Module T-Code WE57 in receiving system only
Hope this will help.
Let me know if you need anything else.
BR/Manas -
How to find the max data transfer rate(disk speed) supported by mobo?
I plan on replacing my current HDD with a new and bigger HDD.
For this I need to know the max data transfer rate(disk speed) that my mobo will support. However, dmidecode is not telling me that. Am I missing something?
Here's dmidecode:
# dmidecode 2.11
SMBIOS 2.5 present.
80 structures occupying 2858 bytes.
Table at 0x000F0450.
Handle 0xDA00, DMI type 218, 101 bytes
OEM-specific Type
Header and Data:
DA 65 00 DA B2 00 17 4B 0E 38 00 00 80 00 80 01
00 02 80 02 80 01 00 00 A0 00 A0 01 00 58 00 58
00 01 00 59 00 59 00 01 00 75 01 75 01 01 00 76
01 76 01 01 00 05 80 05 80 01 00 D1 01 19 00 01
00 15 02 19 00 02 00 1B 00 19 00 03 00 19 00 19
00 00 00 4A 02 4A 02 01 00 0C 80 0C 80 01 00 FF
FF 00 00 00 00
Handle 0xDA01, DMI type 218, 35 bytes
OEM-specific Type
Header and Data:
DA 23 01 DA B2 00 17 4B 0E 38 00 10 F5 10 F5 00
00 11 F5 11 F5 00 00 12 F5 12 F5 00 00 FF FF 00
00 00 00
Handle 0x0000, DMI type 0, 24 bytes
BIOS Information
Vendor: Dell Inc.
Version: A17
Release Date: 04/06/2010
Address: 0xF0000
Runtime Size: 64 kB
ROM Size: 4096 kB
Characteristics:
PCI is supported
PNP is supported
APM is supported
BIOS is upgradeable
BIOS shadowing is allowed
ESCD support is available
Boot from CD is supported
Selectable boot is supported
EDD is supported
Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
3.5"/720 kB floppy services are supported (int 13h)
Print screen service is supported (int 5h)
8042 keyboard services are supported (int 9h)
Serial services are supported (int 14h)
Printer services are supported (int 17h)
ACPI is supported
USB legacy is supported
BIOS boot specification is supported
Function key-initiated network boot is supported
Targeted content distribution is supported
BIOS Revision: 17.0
Handle 0x0100, DMI type 1, 27 bytes
System Information
Manufacturer: Dell Inc.
Product Name: OptiPlex 755
Version: Not Specified
UUID: 44454C4C-5900-1050-8033-C4C04F434731
Wake-up Type: Power Switch
SKU Number: Not Specified
Family: Not Specified
Handle 0x0200, DMI type 2, 8 bytes
Base Board Information
Manufacturer: Dell Inc.
Product Name: 0PU052
Version:
Handle 0x0300, DMI type 3, 13 bytes
Chassis Information
Manufacturer: Dell Inc.
Type: Space-saving
Lock: Not Present
Version: Not Specified
Asset Tag:
Boot-up State: Safe
Power Supply State: Safe
Thermal State: Safe
Security Status: None
Handle 0x0400, DMI type 4, 40 bytes
Processor Information
Socket Designation: CPU
Type: Central Processor
Family: Xeon
Manufacturer: Intel
ID: 76 06 01 00 FF FB EB BF
Signature: Type 0, Family 6, Model 23, Stepping 6
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Not Specified
Voltage: 0.0 V
External Clock: 1333 MHz
Max Speed: 5200 MHz
Current Speed: 2666 MHz
Status: Populated, Enabled
Upgrade: Socket LGA775
L1 Cache Handle: 0x0700
L2 Cache Handle: 0x0701
L3 Cache Handle: Not Provided
Serial Number: Not Specified
Asset Tag: Not Specified
Part Number: Not Specified
Core Count: 2
Core Enabled: 2
Thread Count: 2
Characteristics:
64-bit capable
Handle 0x0700, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 32 kB
Maximum Size: 32 kB
Supported SRAM Types:
Other
Installed SRAM Type: Other
Speed: Unknown
Error Correction Type: None
System Type: Data
Associativity: 8-way Set-associative
Handle 0x0701, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 6144 kB
Maximum Size: 6144 kB
Supported SRAM Types:
Other
Installed SRAM Type: Other
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: <OUT OF SPEC>
Handle 0x0800, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PARALLEL
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-25 female
Port Type: Parallel Port PS/2
Handle 0x0801, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: SERIAL1
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-9 male
Port Type: Serial Port 16550A Compatible
Handle 0x0802, DMI type 126, 9 bytes
Inactive
Handle 0x0803, DMI type 126, 9 bytes
Inactive
Handle 0x0804, DMI type 126, 9 bytes
Inactive
Handle 0x0805, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB1
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0806, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB2
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0807, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB3
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0808, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB4
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0809, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB5
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB6
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB7
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB8
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: ENET
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: RJ-45
Port Type: Network Port
Handle 0x080E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: MIC
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x080F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: LINE-OUT
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0810, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: LINE-IN
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0811, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: HP-OUT
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0812, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: MONITOR
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-15 female
Port Type: Video Port
Handle 0x090A, DMI type 9, 13 bytes
System Slot Information
Designation: SLOT1
Type: x1 Proprietary
Current Usage: In Use
Length: Long
Characteristics:
PME signal is supported
Handle 0x0901, DMI type 126, 13 bytes
Inactive
Handle 0x0902, DMI type 9, 13 bytes
System Slot Information
Designation: SLOT2
Type: 32-bit PCI
Current Usage: Available
Length: Long
ID: 2
Characteristics:
5.0 V is provided
3.3 V is provided
PME signal is supported
Handle 0x0903, DMI type 126, 13 bytes
Inactive
Handle 0x0904, DMI type 126, 13 bytes
Inactive
Handle 0x0905, DMI type 126, 13 bytes
Inactive
Handle 0x0906, DMI type 126, 13 bytes
Inactive
Handle 0x0907, DMI type 126, 13 bytes
Inactive
Handle 0x0908, DMI type 126, 13 bytes
Inactive
Handle 0x0A00, DMI type 10, 6 bytes
On Board Device Information
Type: Video
Status: Disabled
Description: Intel Graphics Media Accelerator 950
Handle 0x0A02, DMI type 10, 6 bytes
On Board Device Information
Type: Ethernet
Status: Enabled
Description: Intel Gigabit Ethernet Controller
Handle 0x0A03, DMI type 10, 6 bytes
On Board Device Information
Type: Sound
Status: Enabled
Description: Intel(R) High Definition Audio Controller
Handle 0x0B00, DMI type 11, 5 bytes
OEM Strings
String 1: www.dell.com
Handle 0x0D00, DMI type 13, 22 bytes
BIOS Language Information
Language Description Format: Long
Installable Languages: 1
en|US|iso8859-1
Currently Installed Language: en|US|iso8859-1
Handle 0x0F00, DMI type 15, 29 bytes
System Event Log
Area Length: 2049 bytes
Header Start Offset: 0x0000
Header Length: 16 bytes
Data Start Offset: 0x0010
Access Method: Memory-mapped physical 32-bit address
Access Address: 0xFFF01000
Status: Valid, Not Full
Change Token: 0x00000018
Header Format: Type 1
Supported Log Type Descriptors: 3
Descriptor 1: POST error
Data Format 1: POST results bitmap
Descriptor 2: System limit exceeded
Data Format 2: System management
Descriptor 3: Log area reset/cleared
Data Format 3: None
Handle 0x1000, DMI type 16, 15 bytes
Physical Memory Array
Location: System Board Or Motherboard
Use: System Memory
Error Correction Type: None
Maximum Capacity: 8 GB
Error Information Handle: Not Provided
Number Of Devices: 4
Handle 0x1100, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_1
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Manufacturer: AD00000000000000
Handle 0x1101, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_3
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1102, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_2
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1103, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_4
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1300, DMI type 19, 15 bytes
Memory Array Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x000FDFFFFFF
Range Size: 4064 MB
Physical Array Handle: 0x1000
Partition Width: 1
Handle 0x1400, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Device Handle: 0x1100
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 1
Interleaved Data Depth: 1
Handle 0x1401, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00080000000
Ending Address: 0x000FDFFFFFF
Range Size: 2016 MB
Physical Device Handle: 0x1101
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 1
Interleaved Data Depth: 1
Handle 0x1402, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Device Handle: 0x1102
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 2
Interleaved Data Depth: 1
Handle 0x1403, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00080000000
Ending Address: 0x000FDFFFFFF
Range Size: 2016 MB
Physical Device Handle: 0x1103
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 2
Interleaved Data Depth: 1
Handle 0x1410, DMI type 126, 19 bytes
Inactive
Handle 0x1800, DMI type 24, 5 bytes
Hardware Security
Power-On Password Status: Enabled
Keyboard Password Status: Not Implemented
Administrator Password Status: Enabled
Front Panel Reset Status: Not Implemented
Handle 0x1900, DMI type 25, 9 bytes
System Power Controls
Next Scheduled Power-on: *-* 00:00:00
Handle 0x1B10, DMI type 27, 12 bytes
Cooling Device
Type: Fan
Status: OK
OEM-specific Information: 0x0000DD00
Handle 0x1B11, DMI type 27, 12 bytes
Cooling Device
Type: Fan
Status: OK
OEM-specific Information: 0x0000DD01
Handle 0x1B12, DMI type 126, 12 bytes
Inactive
Handle 0x1B13, DMI type 126, 12 bytes
Inactive
Handle 0x1B14, DMI type 126, 12 bytes
Inactive
Handle 0x2000, DMI type 32, 11 bytes
System Boot Information
Status: No errors detected
Handle 0x8100, DMI type 129, 8 bytes
OEM-specific Type
Header and Data:
81 08 00 81 01 01 02 01
Strings:
Intel_ASF
Intel_ASF_001
Handle 0x8200, DMI type 130, 20 bytes
OEM-specific Type
Header and Data:
82 14 00 82 24 41 4D 54 01 01 00 00 01 A5 0B 02
00 00 00 00
Handle 0x8300, DMI type 131, 64 bytes
OEM-specific Type
Header and Data:
83 40 00 83 14 00 00 00 00 00 C0 29 05 00 00 00
F8 00 4E 24 00 00 00 00 0D 00 00 00 02 00 03 00
19 04 14 00 01 00 01 02 C8 00 BD 10 00 00 00 00
00 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
Handle 0x8800, DMI type 136, 6 bytes
OEM-specific Type
Header and Data:
88 06 00 88 5A 5A
Handle 0xD000, DMI type 208, 10 bytes
OEM-specific Type
Header and Data:
D0 0A 00 D0 01 03 FE 00 11 02
Handle 0xD100, DMI type 209, 12 bytes
OEM-specific Type
Header and Data:
D1 0C 00 D1 78 03 07 03 04 0F 80 05
Handle 0xD200, DMI type 210, 12 bytes
OEM-specific Type
Header and Data:
D2 0C 00 D2 F8 03 04 03 06 80 04 05
Handle 0xD201, DMI type 126, 12 bytes
Inactive
Handle 0xD400, DMI type 212, 242 bytes
OEM-specific Type
Header and Data:
D4 F2 00 D4 70 00 71 00 00 10 2D 2E 42 00 11 FE
01 43 00 11 FE 00 0F 00 25 FC 00 10 00 25 FC 01
11 00 25 FC 02 12 00 25 FC 03 00 00 25 F3 00 00
00 25 F3 04 00 00 25 F3 08 00 00 25 F3 0C 07 00
23 8F 00 08 00 23 F3 00 09 00 23 F3 04 0A 00 23
F3 08 0B 00 23 8F 10 0C 00 23 8F 20 0E 00 23 8F
30 0D 00 23 8C 40 A6 00 23 8C 41 A7 00 23 8C 42
05 01 22 FD 02 06 01 22 FD 00 8C 00 22 FE 00 8D
00 22 FE 01 9B 00 25 3F 40 9C 00 25 3F 00 09 01
25 3F 80 A1 00 26 F3 00 A2 00 26 F3 08 A3 00 26
F3 04 9F 00 26 FD 02 A0 00 26 FD 00 9D 00 11 FB
04 9E 00 11 FB 00 54 01 23 7F 00 55 01 23 7F 80
5C 00 78 BF 40 5D 00 78 BF 00 04 80 78 F5 0A 01
A0 78 F5 00 93 00 7B 7F 80 94 00 7B 7F 00 8A 00
37 DF 20 8B 00 37 DF 00 03 C0 67 00 05 FF FF 00
00 00
Handle 0xD401, DMI type 212, 172 bytes
OEM-specific Type
Header and Data:
D4 AC 01 D4 70 00 71 00 03 40 59 6D 2D 00 59 FC
02 2E 00 59 FC 00 6E 00 59 FC 01 E0 01 59 FC 03
28 00 59 3F 00 29 00 59 3F 40 2A 00 59 3F 80 2B
00 5A 00 00 2C 00 5B 00 00 55 00 59 F3 00 6D 00
59 F3 04 8E 00 59 F3 08 8F 00 59 F3 00 00 00 55
FB 04 00 00 55 FB 00 23 00 55 7F 00 22 00 55 7F
80 F5 00 58 BF 40 F6 00 58 BF 00 EB 00 55 FE 00
EA 00 55 FE 01 40 01 54 EF 00 41 01 54 EF 10 ED
00 54 F7 00 F0 00 54 F7 08 4A 01 53 DF 00 4B 01
53 DF 20 4C 01 53 7F 00 4D 01 53 7F 80 68 01 56
BF 00 69 01 56 BF 40 FF FF 00 00 00
Handle 0xD402, DMI type 212, 152 bytes
OEM-specific Type
Header and Data:
D4 98 02 D4 70 00 71 00 00 10 2D 2E 2D 01 21 FE
01 2E 01 21 FE 00 97 00 22 FB 00 98 00 22 FB 04
90 00 11 CF 00 91 00 11 CF 20 92 00 11 CF 10 E2
00 27 7F 00 E3 00 27 7F 80 E4 00 27 BF 00 E5 00
27 BF 40 D1 00 22 7F 80 D2 00 22 7F 00 45 01 22
BF 40 44 01 22 BF 00 36 01 21 F1 06 37 01 21 F1
02 38 01 21 F1 00 39 01 21 F1 04 2B 01 11 7F 80
2C 01 11 7F 00 4E 01 65 CF 00 4F 01 65 CF 10 D4
01 65 F3 00 D5 01 65 F3 04 D2 01 65 FC 00 D3 01
65 FC 01 FF FF 00 00 00
Handle 0xD403, DMI type 212, 157 bytes
OEM-specific Type
Header and Data:
D4 9D 03 D4 70 00 71 00 03 40 59 6D 17 01 52 FE
00 18 01 52 FE 01 19 01 52 FB 00 1A 01 52 FB 04
1B 01 52 FD 00 1C 01 52 FD 02 1D 01 52 F7 00 1E
01 52 F7 08 1F 01 52 EF 00 20 01 52 EF 10 21 01
52 BF 00 22 01 52 BF 40 87 00 59 DF 20 88 00 59
DF 00 E8 01 66 FD 00 E9 01 66 FD 02 02 02 53 BF
00 03 02 53 BF 40 04 02 53 EF 00 05 02 53 EF 10
06 02 66 DF 00 07 02 66 DF 20 08 02 66 EF 00 09
02 66 EF 10 17 02 66 F7 00 18 02 66 F7 08 44 02
52 BF 40 45 02 52 BF 00 FF FF 00 00 00
Handle 0xD800, DMI type 126, 9 bytes
Inactive
Handle 0xDD00, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 00 DD 00 01 00 00 00 10 F5 00 00 00 00 00
00 00 00
Handle 0xDD01, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 01 DD 00 01 00 00 00 11 F5 00 00 00 00 00
00 00 00
Handle 0xDD02, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 02 DD 00 01 00 00 00 12 F5 00 00 00 00 00
00 00 00
Handle 0xDE00, DMI type 222, 16 bytes
OEM-specific Type
Header and Data:
DE 10 00 DE C1 0B 00 00 10 05 19 21 01 00 00 01
Handle 0x7F00, DMI type 127, 4 bytes
End Of Table
Hdparm also does not tell me the max data transfer rate (disk speed) of my current drive although this link : www.wdc.com/en/library/sata/2879-001146.pdf says that it is 3.0Gb/s
and here's hdparm -I /dev/sda
/dev/sda:
ATA device, with non-removable media
Model Number: WDC WD800JD-75JNC0
Firmware Revision: 06.01C06
Standards:
Supported: 6 5 4
Likely used: 8
Configuration:
Logical max current
cylinders 16383 16383
heads 16 16
sectors/track 63 63
CHS current addressable sectors: 16514064
LBA user addressable sectors: 156250000
Logical/Physical Sector size: 512 bytes
device size with M = 1024*1024: 76293 MBytes
device size with M = 1000*1000: 80000 MBytes (80 GB)
cache/buffer size = 8192 KBytes
Capabilities:
LBA, IORDY(can be disabled)
Standby timer values: spec'd by Standard, with device specific minimum
R/W multiple sector transfer: Max = 16 Current = 8
Recommended acoustic management value: 128, current value: 254
DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 *udma5
Cycle time: min=120ns recommended=120ns
PIO: pio0 pio1 pio2 pio3 pio4
Cycle time: no flow control=120ns IORDY flow control=120ns
Commands/features:
Enabled Supported:
* SMART feature set
Security Mode feature set
* Power Management feature set
* Write cache
* Look-ahead
* Host Protected Area feature set
* WRITE_BUFFER command
* READ_BUFFER command
* DOWNLOAD_MICROCODE
SET_MAX security extension
Automatic Acoustic Management feature set
* Device Configuration Overlay feature set
* Mandatory FLUSH_CACHE
* SMART error logging
* SMART self-test
* Gen1 signaling speed (1.5Gb/s)
* Host-initiated interface power management
* SMART Command Transport (SCT) feature set
* SCT Long Sector Access (AC1)
* SCT LBA Segment Access (AC2)
* SCT Error Recovery Control (AC3)
* SCT Features Control (AC4)
* SCT Data Tables (AC5)
Security:
Master password revision code = 65534
supported
not enabled
not locked
frozen
not expired: security count
not supported: enhanced erase
Checksum: correct
Last edited by Inxsible (2011-03-27 04:40:49)I just checked my BIOS and my current setting is set at IDE although it also mentions that the default should be AHCI. Currently I have a dual boot of Windows 7 (need it for Tax software) and Arch
So I guess, when I get the new HDD, I will first set it to AHCI and then install the OSes on it. See if NCQ helps any, and if not I will turn it back and re-install (if I have to). I am planning to have Windows only in virtualbox in the new drive.
Anyhoo, while I was in the BIOS I found two things which I had questions about :
1) Under Onboard Devices --> Integrated NIC , my setting is currently set at "On w/PXE" and it says the default should be just "On". Would it be ok to change it back to On since its a single machine and its not booting an OS on any server. I just don't want to have to re-install anything now since I will be doing that in the new HDD.
2) How would I know whether my BIOS would support a 64 bit OS in Virtualbox? I checked some setting under Virtualization, but they weren't very clear.
I will edit this post and let you know exactly what settings were present under the Virtualization sub-section. -
Error in Plan Data Transfer from CO
Hi,
I need to use Plan Data Transfer from CO (FM9C). But when I execute it, I have an error "CO Objects without FM Assgmt".
How can I setup the derivation between CO and FM objects?
All documentation that I've found are for SAP 4.6, but we are using SAP ECC 6.0...Hi,
Are you using former budgeting or BCS? If you use BCS, you should use FMCYCOPI_CO. In any case, to link CO objects to FM entities, use FMDERIVE strategy - it works for planning in the same way as it does for real postings.
Regards,
Eli -
E recruiting Data Transfer for New Employee
Hi all,
We are implementing E-recruitment 3.0, Ecc 6.0 and E recruitment system are in the same system, we processing internal recruitment currently, here i can receive the internal applications, we can able to view and process the applications in recruiter role. Here i can execute the sequence of activities for application process group for received applications, we not integrated any XI systems for e recruitment process.
After processing the activity to be hired, the next activity is Data transfer for new employee, this is also executed successfully for data transfer of employee positions, job, org unit details etc.
1. whether transferred data of applicant is processed via transaction PA48(Hiring of transferred employees)for internal recruitment in R/3 HR system, after the data transfer activity in E recruitment portal screen ?
2. is any other roles and application url available for Hiring internal candidate which could be done in portal E recruitment screen itself with out coming to R/3 HR transactions side ? with out going into PA48 for hiring.
3. any specific roles we have assign for recruiter ?
4. any process carried out in Managerial self service?(according to me MSS is different instance to process recruitment process for internal and external recruitment for Vacancy filling) please correct me my vision on MSS.
your answers and suggestions will be highly appreciated!
Thanks from,
Venkatesh Mani.1. whether transferred data of applicant is processed via transaction PA48(Hiring of transferred employees)for internal recruitment in R/3 HR system, after the data transfer activity in E recruitment portal screen ?
If you are selecting the internal candidate , you need not hire the employee again using PA48. You can trigger transfer / change in position workflow using PCR form.
2. is any other roles and application url available for Hiring internal candidate which could be done in portal E recruitment screen itself with out coming to R/3 HR transactions side ? with out going into PA48 for hiring.
I dont think we have any specific action from eRecruitment side to run the hiring action.This needs to be done from R/3 only.
3. any specific roles we have assign for recruiter ? Not sure about this.
4. any process carried out in Managerial self service?(according to me MSS is different instance to process recruitment process for internal and external recruitment for Vacancy filling) please correct me my vision on MSS.
If its intergrated portal with the Requestor role attached in the manager profile , they will be able to carry out both internal and external candidates selection. I dont think you would require different instance.
We can also wait for someother inputs from forum gurus.
Thanks.
Gautham.
Maybe you are looking for
-
FPGA Code Generation fails with error codes 7 and -1
Hi all, I have been having a weird issue with my LV FPGA compilation in the last couple of days, no matter what I try to compile LV fails to generate the FPGA code files and returns with errors 7 and -1 and complains that the file is not found. This
-
Help with loadmovie in Flash 8
hi flashCoders, this code used to work fine in old versions but now doesn't work theres is the code: <--- _root.createEmptyMovieClip("fundo", 1); fundo.loadMovie("image3.jpg"); fotosArray = ["image1.jpg", "image3.jpg", "image7.jpg"]; function fotosRo
-
I trouble with listeners on a movieclip. does anybody can help me?
I have been working with this for two days and i cant make it work.......I am going crazy.... Ok i have this code if someone can help... i will appreciate that A LOT. The thing is if i compile the program everything works well, if i upload it or test
-
Hsawwan ,can you give me some help?
Although I'm very new, I have made up my mind to become a Oracle ACE in Ebs field. I will achieve this aim by working hard . I have made every mental preparations. can you give me some advice ?
-
Custom Dynamic Stamp Java not working in WIN7
I currently was upgraded from WinXP to WIN7. Running Acrobat Prof 8 with all the updates. I created a dozen customized dynamic stamps that grab info and date/time from the system. Using the following java, the stamps worked perfectly. event.value = (