Hello Gurus,
I would know how transfer the data from cproject 3.1 to cproject 4.5.
I try to explain better:
I have an ECC 6.0 where I upgrade R3 ( from 4.7 to ECC6.0),
on another server 4.7 there is a cProject , the client would have the cProject ( also 3.1) on
only machine 6.0 ( where there is already R3..).
So
I should install the add on for cproject Suite on ECC 6.0 (tcode saint ) = The client has a new release (4.5) without add charge..
so I should:
1. move customizing ( Delivery Customizing is imported into client 000 and may need to be
copied to other clients. For more information, see Note 337623) ok,
2. BSP ? ( I think to update manually... is there another way?)
finally
3. I should transfer the data : How Can I do ? Is There any way to do this? ( with Saint, the system
allows me transfer the data? )
Thanks in advance
Ciaoo
done
Similar Messages
-
Data transfer form 4.7 to ECC 6.0 in upgradation project. How to do?
Hi Experts,
The client is going for an up-gradation from 4.7 to ECC 6.0. The entire data needs to be transferred from 4.7 to ECC 6.0. What is the best possible way to do this?
Please advise.
Regards,
TomeshHi ,
Going for an up-gradation from 4.7 to ECC 6.0. The data needs gets migrated from 4.7 to ECC 6.0.
SAP normally has defined better SAP functionalities in the new system .
In any upgrade project use Tcode SPDD. In this all the dictionary objects u2013 data elements, database tables and structures in the version 4.7 are compared with the upcoming new system.
All you need to do is the check whether the new change is suitable or not.You can make the modifications and then you need to make the migration of data, which can be automate.
the links for your reference.
Link:[https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/304b9de6-f84f-2b10-94af-e5ff7461c18c]
link:[http://solutionbrowser.erp.sap.fmpmedia.com/Default.aspx]
Thanks & Regards,
link:[Lakshmi Narayana] -
LBBIL_INVOICE. Billing Data: Transfer Structure to Smart Forms
Hi...
Can u please help me out in my query regading how the data passes to
LBBIL_INVOICE. Billing Data: Transfer Structure to Smart Forms.
I have an smartform which runs through VF01/VF02/ VF03 while pressing the print preview button.
But if i try to run it directly from driver program, no data wil be displayed. Now i have the requirement to detach from VF03.. and make it to run directly from my driver program.
what shall i have to do to achieve this. Should i have to take all the internal tables saparately or else can i use LBBIL_invoice structure itself.
If i can use that structure itself, how to make the data flow into it. Pls help me.
In my codeing these includes were there. is there anything related , is the data passes because of these includes
INCLUDE rlb_invoice_data_declare.
definition of forms
INCLUDE rlb_invoice_form01.
INCLUDE rlb_print_forms.
Pls clarify my dobut...
Thanks in advance,
Hema1. These are normal structure
2. you can use anywhere but they designed for forms currently.
3. Yes ,it works like it will look at NAST Table -> nast table will connect the TNAPR Table -> tnapr will have smart form print program.
so smart form program calls smartform and it will show output
4. you can create your own structure and use them into anywhere like report program or forms..
5. you can see example simple form name SF_EXAMPLE_01 ,program name is SF_EXAMPLE_01 ,you can design your own form and print program.
Thanks
Seshu -
How to find the max data transfer rate(disk speed) supported by mobo?
I plan on replacing my current HDD with a new and bigger HDD.
For this I need to know the max data transfer rate(disk speed) that my mobo will support. However, dmidecode is not telling me that. Am I missing something?
Here's dmidecode:
# dmidecode 2.11
SMBIOS 2.5 present.
80 structures occupying 2858 bytes.
Table at 0x000F0450.
Handle 0xDA00, DMI type 218, 101 bytes
OEM-specific Type
Header and Data:
DA 65 00 DA B2 00 17 4B 0E 38 00 00 80 00 80 01
00 02 80 02 80 01 00 00 A0 00 A0 01 00 58 00 58
00 01 00 59 00 59 00 01 00 75 01 75 01 01 00 76
01 76 01 01 00 05 80 05 80 01 00 D1 01 19 00 01
00 15 02 19 00 02 00 1B 00 19 00 03 00 19 00 19
00 00 00 4A 02 4A 02 01 00 0C 80 0C 80 01 00 FF
FF 00 00 00 00
Handle 0xDA01, DMI type 218, 35 bytes
OEM-specific Type
Header and Data:
DA 23 01 DA B2 00 17 4B 0E 38 00 10 F5 10 F5 00
00 11 F5 11 F5 00 00 12 F5 12 F5 00 00 FF FF 00
00 00 00
Handle 0x0000, DMI type 0, 24 bytes
BIOS Information
Vendor: Dell Inc.
Version: A17
Release Date: 04/06/2010
Address: 0xF0000
Runtime Size: 64 kB
ROM Size: 4096 kB
Characteristics:
PCI is supported
PNP is supported
APM is supported
BIOS is upgradeable
BIOS shadowing is allowed
ESCD support is available
Boot from CD is supported
Selectable boot is supported
EDD is supported
Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
3.5"/720 kB floppy services are supported (int 13h)
Print screen service is supported (int 5h)
8042 keyboard services are supported (int 9h)
Serial services are supported (int 14h)
Printer services are supported (int 17h)
ACPI is supported
USB legacy is supported
BIOS boot specification is supported
Function key-initiated network boot is supported
Targeted content distribution is supported
BIOS Revision: 17.0
Handle 0x0100, DMI type 1, 27 bytes
System Information
Manufacturer: Dell Inc.
Product Name: OptiPlex 755
Version: Not Specified
UUID: 44454C4C-5900-1050-8033-C4C04F434731
Wake-up Type: Power Switch
SKU Number: Not Specified
Family: Not Specified
Handle 0x0200, DMI type 2, 8 bytes
Base Board Information
Manufacturer: Dell Inc.
Product Name: 0PU052
Version:
Handle 0x0300, DMI type 3, 13 bytes
Chassis Information
Manufacturer: Dell Inc.
Type: Space-saving
Lock: Not Present
Version: Not Specified
Asset Tag:
Boot-up State: Safe
Power Supply State: Safe
Thermal State: Safe
Security Status: None
Handle 0x0400, DMI type 4, 40 bytes
Processor Information
Socket Designation: CPU
Type: Central Processor
Family: Xeon
Manufacturer: Intel
ID: 76 06 01 00 FF FB EB BF
Signature: Type 0, Family 6, Model 23, Stepping 6
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Not Specified
Voltage: 0.0 V
External Clock: 1333 MHz
Max Speed: 5200 MHz
Current Speed: 2666 MHz
Status: Populated, Enabled
Upgrade: Socket LGA775
L1 Cache Handle: 0x0700
L2 Cache Handle: 0x0701
L3 Cache Handle: Not Provided
Serial Number: Not Specified
Asset Tag: Not Specified
Part Number: Not Specified
Core Count: 2
Core Enabled: 2
Thread Count: 2
Characteristics:
64-bit capable
Handle 0x0700, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 32 kB
Maximum Size: 32 kB
Supported SRAM Types:
Other
Installed SRAM Type: Other
Speed: Unknown
Error Correction Type: None
System Type: Data
Associativity: 8-way Set-associative
Handle 0x0701, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 6144 kB
Maximum Size: 6144 kB
Supported SRAM Types:
Other
Installed SRAM Type: Other
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: <OUT OF SPEC>
Handle 0x0800, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PARALLEL
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-25 female
Port Type: Parallel Port PS/2
Handle 0x0801, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: SERIAL1
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-9 male
Port Type: Serial Port 16550A Compatible
Handle 0x0802, DMI type 126, 9 bytes
Inactive
Handle 0x0803, DMI type 126, 9 bytes
Inactive
Handle 0x0804, DMI type 126, 9 bytes
Inactive
Handle 0x0805, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB1
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0806, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB2
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0807, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB3
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0808, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB4
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0809, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB5
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB6
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB7
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: USB8
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x080D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: ENET
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: RJ-45
Port Type: Network Port
Handle 0x080E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: MIC
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x080F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: LINE-OUT
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0810, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: LINE-IN
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0811, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: HP-OUT
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: Mini Jack (headphones)
Port Type: Audio Port
Handle 0x0812, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: MONITOR
Internal Connector Type: None
External Reference Designator: Not Specified
External Connector Type: DB-15 female
Port Type: Video Port
Handle 0x090A, DMI type 9, 13 bytes
System Slot Information
Designation: SLOT1
Type: x1 Proprietary
Current Usage: In Use
Length: Long
Characteristics:
PME signal is supported
Handle 0x0901, DMI type 126, 13 bytes
Inactive
Handle 0x0902, DMI type 9, 13 bytes
System Slot Information
Designation: SLOT2
Type: 32-bit PCI
Current Usage: Available
Length: Long
ID: 2
Characteristics:
5.0 V is provided
3.3 V is provided
PME signal is supported
Handle 0x0903, DMI type 126, 13 bytes
Inactive
Handle 0x0904, DMI type 126, 13 bytes
Inactive
Handle 0x0905, DMI type 126, 13 bytes
Inactive
Handle 0x0906, DMI type 126, 13 bytes
Inactive
Handle 0x0907, DMI type 126, 13 bytes
Inactive
Handle 0x0908, DMI type 126, 13 bytes
Inactive
Handle 0x0A00, DMI type 10, 6 bytes
On Board Device Information
Type: Video
Status: Disabled
Description: Intel Graphics Media Accelerator 950
Handle 0x0A02, DMI type 10, 6 bytes
On Board Device Information
Type: Ethernet
Status: Enabled
Description: Intel Gigabit Ethernet Controller
Handle 0x0A03, DMI type 10, 6 bytes
On Board Device Information
Type: Sound
Status: Enabled
Description: Intel(R) High Definition Audio Controller
Handle 0x0B00, DMI type 11, 5 bytes
OEM Strings
String 1: www.dell.com
Handle 0x0D00, DMI type 13, 22 bytes
BIOS Language Information
Language Description Format: Long
Installable Languages: 1
en|US|iso8859-1
Currently Installed Language: en|US|iso8859-1
Handle 0x0F00, DMI type 15, 29 bytes
System Event Log
Area Length: 2049 bytes
Header Start Offset: 0x0000
Header Length: 16 bytes
Data Start Offset: 0x0010
Access Method: Memory-mapped physical 32-bit address
Access Address: 0xFFF01000
Status: Valid, Not Full
Change Token: 0x00000018
Header Format: Type 1
Supported Log Type Descriptors: 3
Descriptor 1: POST error
Data Format 1: POST results bitmap
Descriptor 2: System limit exceeded
Data Format 2: System management
Descriptor 3: Log area reset/cleared
Data Format 3: None
Handle 0x1000, DMI type 16, 15 bytes
Physical Memory Array
Location: System Board Or Motherboard
Use: System Memory
Error Correction Type: None
Maximum Capacity: 8 GB
Error Information Handle: Not Provided
Number Of Devices: 4
Handle 0x1100, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_1
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Manufacturer: AD00000000000000
Handle 0x1101, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_3
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1102, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_2
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1103, DMI type 17, 27 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 64 bits
Data Width: 64 bits
Size: 1024 MB
Form Factor: DIMM
Set: None
Locator: DIMM_4
Bank Locator: Not Specified
Type: DDR2
Type Detail: Synchronous
Speed: 667 MHz
Handle 0x1300, DMI type 19, 15 bytes
Memory Array Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x000FDFFFFFF
Range Size: 4064 MB
Physical Array Handle: 0x1000
Partition Width: 1
Handle 0x1400, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Device Handle: 0x1100
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 1
Interleaved Data Depth: 1
Handle 0x1401, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00080000000
Ending Address: 0x000FDFFFFFF
Range Size: 2016 MB
Physical Device Handle: 0x1101
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 1
Interleaved Data Depth: 1
Handle 0x1402, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Device Handle: 0x1102
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 2
Interleaved Data Depth: 1
Handle 0x1403, DMI type 20, 19 bytes
Memory Device Mapped Address
Starting Address: 0x00080000000
Ending Address: 0x000FDFFFFFF
Range Size: 2016 MB
Physical Device Handle: 0x1103
Memory Array Mapped Address Handle: 0x1300
Partition Row Position: 1
Interleave Position: 2
Interleaved Data Depth: 1
Handle 0x1410, DMI type 126, 19 bytes
Inactive
Handle 0x1800, DMI type 24, 5 bytes
Hardware Security
Power-On Password Status: Enabled
Keyboard Password Status: Not Implemented
Administrator Password Status: Enabled
Front Panel Reset Status: Not Implemented
Handle 0x1900, DMI type 25, 9 bytes
System Power Controls
Next Scheduled Power-on: *-* 00:00:00
Handle 0x1B10, DMI type 27, 12 bytes
Cooling Device
Type: Fan
Status: OK
OEM-specific Information: 0x0000DD00
Handle 0x1B11, DMI type 27, 12 bytes
Cooling Device
Type: Fan
Status: OK
OEM-specific Information: 0x0000DD01
Handle 0x1B12, DMI type 126, 12 bytes
Inactive
Handle 0x1B13, DMI type 126, 12 bytes
Inactive
Handle 0x1B14, DMI type 126, 12 bytes
Inactive
Handle 0x2000, DMI type 32, 11 bytes
System Boot Information
Status: No errors detected
Handle 0x8100, DMI type 129, 8 bytes
OEM-specific Type
Header and Data:
81 08 00 81 01 01 02 01
Strings:
Intel_ASF
Intel_ASF_001
Handle 0x8200, DMI type 130, 20 bytes
OEM-specific Type
Header and Data:
82 14 00 82 24 41 4D 54 01 01 00 00 01 A5 0B 02
00 00 00 00
Handle 0x8300, DMI type 131, 64 bytes
OEM-specific Type
Header and Data:
83 40 00 83 14 00 00 00 00 00 C0 29 05 00 00 00
F8 00 4E 24 00 00 00 00 0D 00 00 00 02 00 03 00
19 04 14 00 01 00 01 02 C8 00 BD 10 00 00 00 00
00 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
Handle 0x8800, DMI type 136, 6 bytes
OEM-specific Type
Header and Data:
88 06 00 88 5A 5A
Handle 0xD000, DMI type 208, 10 bytes
OEM-specific Type
Header and Data:
D0 0A 00 D0 01 03 FE 00 11 02
Handle 0xD100, DMI type 209, 12 bytes
OEM-specific Type
Header and Data:
D1 0C 00 D1 78 03 07 03 04 0F 80 05
Handle 0xD200, DMI type 210, 12 bytes
OEM-specific Type
Header and Data:
D2 0C 00 D2 F8 03 04 03 06 80 04 05
Handle 0xD201, DMI type 126, 12 bytes
Inactive
Handle 0xD400, DMI type 212, 242 bytes
OEM-specific Type
Header and Data:
D4 F2 00 D4 70 00 71 00 00 10 2D 2E 42 00 11 FE
01 43 00 11 FE 00 0F 00 25 FC 00 10 00 25 FC 01
11 00 25 FC 02 12 00 25 FC 03 00 00 25 F3 00 00
00 25 F3 04 00 00 25 F3 08 00 00 25 F3 0C 07 00
23 8F 00 08 00 23 F3 00 09 00 23 F3 04 0A 00 23
F3 08 0B 00 23 8F 10 0C 00 23 8F 20 0E 00 23 8F
30 0D 00 23 8C 40 A6 00 23 8C 41 A7 00 23 8C 42
05 01 22 FD 02 06 01 22 FD 00 8C 00 22 FE 00 8D
00 22 FE 01 9B 00 25 3F 40 9C 00 25 3F 00 09 01
25 3F 80 A1 00 26 F3 00 A2 00 26 F3 08 A3 00 26
F3 04 9F 00 26 FD 02 A0 00 26 FD 00 9D 00 11 FB
04 9E 00 11 FB 00 54 01 23 7F 00 55 01 23 7F 80
5C 00 78 BF 40 5D 00 78 BF 00 04 80 78 F5 0A 01
A0 78 F5 00 93 00 7B 7F 80 94 00 7B 7F 00 8A 00
37 DF 20 8B 00 37 DF 00 03 C0 67 00 05 FF FF 00
00 00
Handle 0xD401, DMI type 212, 172 bytes
OEM-specific Type
Header and Data:
D4 AC 01 D4 70 00 71 00 03 40 59 6D 2D 00 59 FC
02 2E 00 59 FC 00 6E 00 59 FC 01 E0 01 59 FC 03
28 00 59 3F 00 29 00 59 3F 40 2A 00 59 3F 80 2B
00 5A 00 00 2C 00 5B 00 00 55 00 59 F3 00 6D 00
59 F3 04 8E 00 59 F3 08 8F 00 59 F3 00 00 00 55
FB 04 00 00 55 FB 00 23 00 55 7F 00 22 00 55 7F
80 F5 00 58 BF 40 F6 00 58 BF 00 EB 00 55 FE 00
EA 00 55 FE 01 40 01 54 EF 00 41 01 54 EF 10 ED
00 54 F7 00 F0 00 54 F7 08 4A 01 53 DF 00 4B 01
53 DF 20 4C 01 53 7F 00 4D 01 53 7F 80 68 01 56
BF 00 69 01 56 BF 40 FF FF 00 00 00
Handle 0xD402, DMI type 212, 152 bytes
OEM-specific Type
Header and Data:
D4 98 02 D4 70 00 71 00 00 10 2D 2E 2D 01 21 FE
01 2E 01 21 FE 00 97 00 22 FB 00 98 00 22 FB 04
90 00 11 CF 00 91 00 11 CF 20 92 00 11 CF 10 E2
00 27 7F 00 E3 00 27 7F 80 E4 00 27 BF 00 E5 00
27 BF 40 D1 00 22 7F 80 D2 00 22 7F 00 45 01 22
BF 40 44 01 22 BF 00 36 01 21 F1 06 37 01 21 F1
02 38 01 21 F1 00 39 01 21 F1 04 2B 01 11 7F 80
2C 01 11 7F 00 4E 01 65 CF 00 4F 01 65 CF 10 D4
01 65 F3 00 D5 01 65 F3 04 D2 01 65 FC 00 D3 01
65 FC 01 FF FF 00 00 00
Handle 0xD403, DMI type 212, 157 bytes
OEM-specific Type
Header and Data:
D4 9D 03 D4 70 00 71 00 03 40 59 6D 17 01 52 FE
00 18 01 52 FE 01 19 01 52 FB 00 1A 01 52 FB 04
1B 01 52 FD 00 1C 01 52 FD 02 1D 01 52 F7 00 1E
01 52 F7 08 1F 01 52 EF 00 20 01 52 EF 10 21 01
52 BF 00 22 01 52 BF 40 87 00 59 DF 20 88 00 59
DF 00 E8 01 66 FD 00 E9 01 66 FD 02 02 02 53 BF
00 03 02 53 BF 40 04 02 53 EF 00 05 02 53 EF 10
06 02 66 DF 00 07 02 66 DF 20 08 02 66 EF 00 09
02 66 EF 10 17 02 66 F7 00 18 02 66 F7 08 44 02
52 BF 40 45 02 52 BF 00 FF FF 00 00 00
Handle 0xD800, DMI type 126, 9 bytes
Inactive
Handle 0xDD00, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 00 DD 00 01 00 00 00 10 F5 00 00 00 00 00
00 00 00
Handle 0xDD01, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 01 DD 00 01 00 00 00 11 F5 00 00 00 00 00
00 00 00
Handle 0xDD02, DMI type 221, 19 bytes
OEM-specific Type
Header and Data:
DD 13 02 DD 00 01 00 00 00 12 F5 00 00 00 00 00
00 00 00
Handle 0xDE00, DMI type 222, 16 bytes
OEM-specific Type
Header and Data:
DE 10 00 DE C1 0B 00 00 10 05 19 21 01 00 00 01
Handle 0x7F00, DMI type 127, 4 bytes
End Of Table
Hdparm also does not tell me the max data transfer rate (disk speed) of my current drive although this link : www.wdc.com/en/library/sata/2879-001146.pdf says that it is 3.0Gb/s
and here's hdparm -I /dev/sda
/dev/sda:
ATA device, with non-removable media
Model Number: WDC WD800JD-75JNC0
Firmware Revision: 06.01C06
Standards:
Supported: 6 5 4
Likely used: 8
Configuration:
Logical max current
cylinders 16383 16383
heads 16 16
sectors/track 63 63
CHS current addressable sectors: 16514064
LBA user addressable sectors: 156250000
Logical/Physical Sector size: 512 bytes
device size with M = 1024*1024: 76293 MBytes
device size with M = 1000*1000: 80000 MBytes (80 GB)
cache/buffer size = 8192 KBytes
Capabilities:
LBA, IORDY(can be disabled)
Standby timer values: spec'd by Standard, with device specific minimum
R/W multiple sector transfer: Max = 16 Current = 8
Recommended acoustic management value: 128, current value: 254
DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 *udma5
Cycle time: min=120ns recommended=120ns
PIO: pio0 pio1 pio2 pio3 pio4
Cycle time: no flow control=120ns IORDY flow control=120ns
Commands/features:
Enabled Supported:
* SMART feature set
Security Mode feature set
* Power Management feature set
* Write cache
* Look-ahead
* Host Protected Area feature set
* WRITE_BUFFER command
* READ_BUFFER command
* DOWNLOAD_MICROCODE
SET_MAX security extension
Automatic Acoustic Management feature set
* Device Configuration Overlay feature set
* Mandatory FLUSH_CACHE
* SMART error logging
* SMART self-test
* Gen1 signaling speed (1.5Gb/s)
* Host-initiated interface power management
* SMART Command Transport (SCT) feature set
* SCT Long Sector Access (AC1)
* SCT LBA Segment Access (AC2)
* SCT Error Recovery Control (AC3)
* SCT Features Control (AC4)
* SCT Data Tables (AC5)
Security:
Master password revision code = 65534
supported
not enabled
not locked
frozen
not expired: security count
not supported: enhanced erase
Checksum: correct
Last edited by Inxsible (2011-03-27 04:40:49)I just checked my BIOS and my current setting is set at IDE although it also mentions that the default should be AHCI. Currently I have a dual boot of Windows 7 (need it for Tax software) and Arch
So I guess, when I get the new HDD, I will first set it to AHCI and then install the OSes on it. See if NCQ helps any, and if not I will turn it back and re-install (if I have to). I am planning to have Windows only in virtualbox in the new drive.
Anyhoo, while I was in the BIOS I found two things which I had questions about :
1) Under Onboard Devices --> Integrated NIC , my setting is currently set at "On w/PXE" and it says the default should be just "On". Would it be ok to change it back to On since its a single machine and its not booting an OS on any server. I just don't want to have to re-install anything now since I will be doing that in the new HDD.
2) How would I know whether my BIOS would support a 64 bit OS in Virtualbox? I checked some setting under Virtualization, but they weren't very clear.
I will edit this post and let you know exactly what settings were present under the Virtualization sub-section. -
Error while executing Initialize with Data Transfer for 0FI_GL_10
Hello All,
Post Pre prod refresh, our timestamp for the datasource 0FI_GL_10 got reset. Due to which our deltas did not bring any records to the BW system.
First we did an Initialize without data transfer for all the BW related datasources. The deltas were then set properly for all datasources except 0FI_GL_10.
We then raised a message to SAP and they suggested to run the 'Initialize with data transfer' for 0FI_GL_10 so that the timestamp is set and accordingly the deltas are fixed.
The issue now is we are getting the following error message while running INIT with data transfer.
Job terminated in source system --> Request set to red
Message no. RSM078
We have copied the data till July 1st week of 2011.
Please advice. The issue is very critical.
Thanks & Regards
SnehaHi Arvind
Thanks for your inputs.
Please find below the details of the short dump.
Runtime Errors DBIF_RSQL_SQL_ERROR
Exception CX_SY_OPEN_SQL_DB
Date and Time 09/07/2011 11:25:32
Short text
SQL error in the database when accessing a table.
What can you do?
Note which actions and input led to the error.
For further help in handling the problem, contact your SAP administrator
You can use the ABAP dump analysis transaction ST22 to view and manage
termination messages, in particular for long term reference.
How to correct the error
Database error text........: "ORA-01652: unable to extend temp segment by 128
in tablespace PSAPTEMP"
Internal call code.........: "[RSQL/FTCH/FAGLFLEXT ]"
Please check the entries in the system log (Transaction SM21).
If the error occures in a non-modified SAP program, you may be able to
find an interim solution in an SAP Note.
If you have access to SAP Notes, carry out a search with the following
keywords:
"DBIF_RSQL_SQL_ERROR" "CX_SY_OPEN_SQL_DB"
Information on where terminated
Termination occurred in the ABAP program "GP_GLX_FAGLFLEXT" - in
"FETCH_TO_ISTRUCTURE".
The main program was "SBIE0001 ".
In the source code you have the termination point in line 903
of the (Include) program "GP_GLX_FAGLFLEXT".
The program "GP_GLX_FAGLFLEXT" was started as a background job.
Job Name....... "BIREQU_4N3PZQ12IA0X0PYGEA85IG39S"
Job Initiator.. "BIWREMOTE"
Job Number..... 11203300
The termination is caused because exception "CX_SY_OPEN_SQL_DB" occurred in
procedure "FETCH_TO_ISTRUCTURE" "(FORM)", but it was neither handled locally
nor declared
in the RAISING clause of its signature.
The procedure is in program "GP_GLX_FAGLFLEXT "; its source code begins in line
840 of the (Include program "GP_GLX_FAGLFLEXT ". -
How to populate new record on data entry form based on search results?
Hello,
I'm new to jdeveloper im using version 11.1.2.1.0.
Usually Im using forms 10g.
I created search panel with table and its working but problem is how to transfer/populate all the field value according to that search result to New data Entry Form
by clicking the table record or a button.
Given :
TABLES,EO
1. PatientMasterIndex
2. PatientTransactionMaster <<---- master
3. PatientTransactionDetail <<-- detail relation
Here the scenario,
After Search of any patient, when i clicked one or more patient (which Jdeveloper allow multi select on jtable) on the table record it should automatically transfer or copied to the text field, i want to show on the form of PatientTransactionMaster like PatientNumber,PatientInsuranceNumber etc. to be save on db as new record, also non database field for view only like patient Name,address,age.
IN forms i can do that by :PatientTransactionMaster.PatientNumber := :blocksearch.PatientSearchNumber ,etc.....
or an item trigger to populate the said PatientTransactionMaster block. ( select .... into :PatientTransactionMaster.PatientNumber,etc....)
Any suggestion,links,sample is highly appreciated.
Sorry for my english.
Thank you very muchHi,
Do you want to create a detail record that will include some values from your master record??
Or do you want to create a record with values from your Search criteria, only in the case you do not have any results?
if it is the second case.
When do you want to do that? After a press of button? or immediately?
In general you have to handle the values from search criteria.
Additionally, if you use ViewCriteria, you have to have bind variables for your search criteria that you will want to use.
So in general, you have to know the values by using bind variables, understand that the query has no results (This can be done in many ways, depending on your implementation. if you are using a button, you could make a disable condition with iterator.estimatedRowCount property.)
Perform the insert operation with the values from the bind variables.
Regards,
Dimitris. -
Field symbols not working in data transfer VOFM routine
Hi,
I have been trying to set a value using field symbols, however for some reasons its not working. I am using a field symbol in a data transfer routine and the value which I am trying to set is a standard field outside the VOFM routine code.
I am trying to set a field gla_subrc which is actually a changing parameter.
The actual paramter is gn_subrc of type sy-subrc and within the form the name is gla_subrc. I need to set this changing parameter gla_subrc using the data transfer routine.
Is there a specific rule that field symbols dont work for changing paramters within subroutine or is there a specific syntax.
The syntax I am using is
ASSIGN ('(SAPLV50S)gla_subrc') to <fs>.
I also used the local program name instead of main program but still that does not work. Tried using the actual parameter as well.
Can someone please help me in this.
Thanks & Regards,
Naresh.I need to stop outbound delivery creation against STO using vl10b transaction. The only way to stop creation is using data transfer delivery VOFM routine.
If i give an error message MESSAGE E001, this will give a hard error which is not acceptable. To avoid this, i use a perform message statment with message id and certain parameters which can displayed in a log.
However to make sure this message is displayed in log, I am clearing a work area having specific data needed for delivery creation.
Because of this clear, my error message gets captured in log but along with this another fake message is displayed in log which caused by the clear message.
The user gets confused as he now sees 2 messages, 1 which is correct and other 1 which is fake and that confuses him.
Data transfer routine is not the best place to give messages in log but we have very few options. The only way the system can give 1 message is if i set gla_subrc to 1. This is a variable which will help the system understand that the delivery should not be created as there is something wrong because the value is 1. Hence it will stop the creation and instead display whatever message i had passed to the log.
I need to somehow set this variable to 1 based on lot of analysis that has been done in the past.
Please let me know if there is any way by which we can fix this.
Thanks & Regards,
Naresh. -
License server in data transfer workbench
Dear All Experts/Gurus,
I have a problem about log on to data transfer workbench (DTW). I don't understand why I must put numbers in license server field before log on to Data transfer workbench ? In the license server field of license administration form, I've seen the license server is words for example jimmymc, then beside it 40000.
I log on DTW, I fill jimmymc in the license server field but I've got error message:
"connection to jimmymc has failed. Error code 100000001. Connection with license server failed"
I don't understand why it succeeds if I fill numbers for example 130.1.2.5:40000, it works successful. What actually the function of license server field ? why could it be different with license server in the license administration form ?
I apreciate your answer. TIA
Rgds,Jimmy,
The net-net is that ... the way you log into the DTW as of the 2005A version is different becasue the overall licensing mechanism used by SAP Business One for 2005 changed from what was used in version 2004. The licensing mechanism now uses CORBA. This allows connection without having to have an IP Address, but you can still use one as you have seen. When you install the License Server for Business One, the default connection "port" used and is defaulted to in the License Server is 30000 ... although you can change this to any port not being used. Again ... the net-net is that is how it works and that is what is now required for connection or use the IP.
HTH,
Eddy -
Data transfer from sap r/3 into excel sheet for mi01
hi gurus,
as i am a xi consultant i got requirement to write a program for data transfer from sap r/3 into excel sheet for MI01.can any body help me by giving sample code or example for this requirement.please help me.Hi Rohit,
This is an upload program and it has used both function modules to upload from an excel to R3 and to download from R3 onto excel.
GUI_UPLOAD
GUI_DOWNLOAD
are the function modules used.
Hope this helps,
*Output: Downloads error records onto presentation server,
* Displays report with number of success and error records
REPORT ZMCG047CONTR NO STANDARD PAGE HEADING
LINE-SIZE 255
MESSAGE-ID ZM.
*& Table declarations
TABLES : T001W, "Plants/Branches
T024E, "Purchasing Organizations
T001. "Company Codes
* TYPE-POOLS DECLARATION
TYPE-POOLS : SLIS.
* Types Declaration *
TYPES: BEGIN OF T_RECORD, "record storing contract info
LIFNR(010), "Vendor Number
EVART(004), "Agreement Type
EKORG(004), "Purchasing Organization
EKGRP(003), "Purchasing Group
WERKS(004), "Plant
LGORT(004), "Storage Location
KDATB(010), "Valid start Date
KDATE(010), "Valid End Date
ZTERM(004), "Payment Terms
KTWRT(020), "Target Value
EPSTP(001), "Item Category
EMATN(018), "Material Number
KTMNG(017), "Target Quantity
NETPR(014), "Net Price
PEINH(006), "Net Price Unit
BPRME(003), "Net Price Order Price Unit
IDNLF(035), "Vendor Material number
WEBRE(001), "GR Based-IV
MEPRF(001), "Pricing Date Category
LTEX1(040), "Info Text
DATAB(010), "Valid From
DATBI(010), "Valid To
KSCHL(004), "Condition Type
KBETR(016), "Condition Rate if scale is not given
KONWA(005), "Currency
KPEIN(005), "Condition Pricing Unit
KMEIN(003), "Condition Unit of Measure
KSTBM(019), "Scale
KBETR_01(016), "Scale Rate
DEL_FLAG, "Delete Flag Indicator
ERR_MSG(100), "Error Message
END OF T_RECORD,
BEGIN OF T_ERR_RECORD, "to have error records stored
LIFNR(010), "Vendor Number
EVART(004), "Agreement Type
EKORG(004), "Purchasing Organization
EKGRP(003), "Purchasing Group
WERKS(004), "Plant
LGORT(004), "Storage Location
KDATB(010), "Valid start Date
KDATE(010), "Valid End Date
ZTERM(004), "Payment Terms
KTWRT(020), "Target Value
EPSTP(001), "Item Category
EMATN(018), "Material Number
KTMNG(017), "Target Quantity
NETPR(014), "Net Price
PEINH(006), "Net Price Unit
BPRME(003), "Net Price Order Price Unit
IDNLF(035), "Vendor Material number
WEBRE(001), "GR Based-IV
MEPRF(001), "Pricing Date Category
LTEX1(040), "Info Text
DATAB(010), "Valid From
DATBI(010), "Valid To
KSCHL(004), "Condition Type
KBETR(016), "Condition Rate if scale is not given
KONWA(005), "Currency
KPEIN(005), "Condition Pricing Unit
KMEIN(003), "Condition Unit of Measure
KSTBM(019), "Scale
KBETR_01(016), "Scale Rate
DEL_FLAG, "Delete Flag Indicator
ERR_MSG(100), "Error Message
END OF T_ERR_RECORD,
BEGIN OF T_LOEKZ, "To have deletion indicators for materials
LOEKZ(001), "Deletion indicator in purchasing document
EMATN(018), "Material Number
WERKS(004), "Plant
LGORT(004), "Storage Location
BSTYP(001), "Purchasing document category
END OF T_LOEKZ,
BEGIN OF T_MATNR, " Type definition to store details of materials
MATNR(018), "Material Number
END OF T_MATNR,
BEGIN OF T_T001, " Type definition for company codes
BUKRS(004), " Company Code
END OF T_T001,
BEGIN OF T_ZMVXREF, "Cross-Reference table type
D_ALTKN(10), "Legacy Vendor Number
D_BUKRS(4), "Legacy Company Code
M_ALTKN(10), "SAP Company Code
END OF T_ZMVXREF,
BEGIN OF T_LFA1, "Master data of vendors
LIFNR(10), "Vendor Number
END OF T_LFA1,
* Type Declaration for T024E (Company Codes)
BEGIN OF T_T024E,
EKORG LIKE T024E-EKORG, "Purchasing organization
BUKRS LIKE T024E-BUKRS, "Company Code
END OF T_T024E,
* Type Declaration for t001w (Plant)
BEGIN OF T_T001W,
WERKS LIKE T001W-WERKS, "Plant
END OF T_T001W,
* Type Declatation for String Line
BEGIN OF T_STR1, "#EC NEEDED
SLINE(6000) TYPE C,
END OF T_STR1.
TYPES: BEGIN OF T_BDCDATA. "BDC Data
INCLUDE STRUCTURE BDCDATA.
TYPES: END OF T_BDCDATA.
* Internal Tables Declaration *
DATA:
* Internal table to store input file data
I_RECORD TYPE STANDARD TABLE OF T_RECORD INITIAL SIZE 0,
* Internal table to capture errors
I_ERR_REC TYPE STANDARD TABLE OF T_ERR_RECORD INITIAL SIZE 0,
* Internal table to check for deletion indicators
I_LOEKZ TYPE STANDARD TABLE OF T_LOEKZ INITIAL SIZE 0,
* Internal table to check for material numbers
I_MATNR TYPE STANDARD TABLE OF T_MATNR INITIAL SIZE 0,
* Internal table used for storing Cross-Reference data of Vendor
I_ZMVXREF TYPE STANDARD TABLE OF T_ZMVXREF INITIAL SIZE 0,
* Internal table for holding Vendor Numbers from Master table
I_LFA1 TYPE STANDARD TABLE OF T_LFA1 INITIAL SIZE 0,
* Internal table for holding Purchase Org and Company Codes
I_T024E TYPE STANDARD TABLE OF T_T024E INITIAL SIZE 0,
* Internal table for holding Plants
I_T001W TYPE STANDARD TABLE OF T_T001W INITIAL SIZE 0,
* Internal table for storing a list of Company Codes
I_T001 TYPE STANDARD TABLE OF T_T001 INITIAL SIZE 0,
* Internal table used for ALV Reporting
I_FIELDCAT TYPE SLIS_T_FIELDCAT_ALV,
* Internal table used for holding List Header
I_LISTHEADER TYPE SLIS_T_LISTHEADER, "EC NEEDED
* Internal table to hold ALV Event
I_ALV_EVENT TYPE SLIS_T_EVENT,
* Internal table to hold Sort Info for ALV Report
I_SORT TYPE SLIS_T_SORTINFO_ALV,
* Internal table for BDC Data
I_BDCDATA TYPE STANDARD TABLE OF T_BDCDATA INITIAL SIZE 0,
* Internal table for messages
I_MESSTAB TYPE TABLE OF BDCMSGCOLL,
* Internal table for String line
I_STR1 TYPE STANDARD TABLE OF T_STR1 INITIAL SIZE 0.
* Work Area Declaration *
DATA:
* Work Area to hold data for the Open Contract
WA_RECORD TYPE T_RECORD,
* Work Area to hold previous record data
WA_RECORDPREV TYPE T_RECORD,
* Work Area to hold errors
WA_ERR_REC TYPE T_ERR_RECORD,
* Work Area to hold the Deletion Indicator of materials
WA_LOEKZ TYPE T_LOEKZ,
* Work Area to hold Material numbers of required materials
WA_MATNR TYPE T_MATNR, "EC NEEDED
* Work Area to hold errors occured while performing BDC
WA_MESSTAB TYPE BDCMSGCOLL,
* Work Area to hold field catalog for ALV Reports
WA_FIELDCAT TYPE SLIS_FIELDCAT_ALV,
* Work Area to hold list header data for ALV reports
WA_LISTHEADER TYPE SLIS_LISTHEADER,
* Work Area to hold ALV Event
WA_ALV_EVENT LIKE LINE OF I_ALV_EVENT, "EC NEEDED
* Work Area to hold Layout of ALV Report
WA_LAYOUT TYPE SLIS_LAYOUT_ALV,
* Work Area to hold Cross-Reference data of Vendor
WA_ZMVXREF TYPE T_ZMVXREF,
* Work Area to hold Vendor Numbers from Master table
WA_LFA1 TYPE T_LFA1, "EC NEEDED
* Work Area to hold Purchase Org and Company Codes
WA_T024E TYPE T_T024E,
* Work Area to hold Company Codes
WA_T001 TYPE T_T001,
* Work Area to hold Plants
WA_T001W TYPE T_T001W,
* Work Area to hold Sort Info for ALV Report
WA_SORT TYPE SLIS_SORTINFO_ALV,
* Work Area to hold BDC Data
WA_BDCDATA TYPE T_BDCDATA,
* Work Area for String line
WA_STR1 TYPE T_STR1.
* Variables Declaration *
DATA: V_ERRMSG(500), "To temporarily store the error message
V_CONV_DATE(10) TYPE C, "To capture the converted date format
V_DATE LIKE SY-DATUM,
V_REPID LIKE SY-REPID, "holds report id
V_CROSS_REFERENCE_ERROR TYPE I, " cross-reference error
V_INPUTERROR_FLAG VALUE '', " input error status
V_FILENAME TYPE STRING, " File Name
VEN_FLAG(1), " at new status
MAT_FLAG(1), " at new status
V_IND(2) TYPE N, " index of table control
V_IND2(2) TYPE N, " index of table control
V_IND3(2) TYPE N, " index of table control
V_EVRTP1(20),
V_EPSTP1(20),
V_EMATN1(20),
V_KTMNG1(20),
V_NETPR1(20),
V_PEINH1(20),
V_BPRME1(20),
V_TCSELFLAG1(20),
V_KSCHL2(20),
V_KBETR2(20),
V_KONWA2(20),
V_KPEIN2(20),
V_KMEIN2(20),
V_SELKZ2(20),
V_KBETR3(20),
V_KSTBM3(20),
V_LINE TYPE I,
V_STR TYPE X VALUE '09',
V_EXIST TYPE C,
V_EXIST1 TYPE C,
V_ISDIR TYPE C,
V_ISDIR1 TYPE C.
* Constants Declaration *
CONSTANTS: C_TCODE(5) VALUE 'ME31K', "Trx code - Open Contract Creation
C_TRUE VALUE 'X', " Del_Flag indicator
C_LOEKZ_MARKED VALUE 'X', "Deletion indicator for material
C_INPUTERROR_FLAG_YES VALUE 'X', "Input File Indicator
C_VEN_ERR1 VALUE 1, "Error Indicator
C_16(2) VALUE '16',
C_VEN_ERR2 VALUE 2, "Error Indicator
C_VEN_ERR3 VALUE 3, "Error Indicator
C_VEN_SUCS VALUE 0, "Success Indicator
C_SUCCESS LIKE SY-SUBRC VALUE '0',
C_STRUE VALUE 'S', "Del_flag for SAP Errors
C_YTRUE VALUE 'Y', "Del_flag for Success Records
C_MSGTYP_E VALUE 'E', "holds error message type
C_MSGTYP_S VALUE 'S', "holds success message type
C_BSTYP VALUE 'K', "Purchasing Document type is Contract
C_BACKGROUND VALUE 'N', "Background mode
C_FOREGROUND VALUE 'A', "All Screen mode
C_ERRORS VALUE 'E', "Error screen mode
C_WK(2) VALUE 'WK'. "Value Contract
* Selection Screen *
SELECTION-SCREEN BEGIN OF BLOCK B2 WITH FRAME TITLE TEXT-033.
SELECTION-SCREEN SKIP.
SELECT-OPTIONS:
* Plant
S_WERKS FOR T001W-WERKS OBLIGATORY,
* Purchase Organization
S_EKORG FOR T024E-EKORG OBLIGATORY.
* Company Code
PARAMETER P_BUKRS LIKE T001-BUKRS OBLIGATORY.
SELECTION-SCREEN SKIP.
SELECTION-SCREEN ULINE.
SELECTION-SCREEN BEGIN OF LINE.
SELECTION-SCREEN POSITION 3.
PARAMETER RB_SERVE RADIOBUTTON GROUP RBX DEFAULT 'X' USER-COMMAND U1.
SELECTION-SCREEN COMMENT 6(19) TEXT-036.
SELECTION-SCREEN POSITION 37.
PARAMETER RB_LOCAL RADIOBUTTON GROUP RBX.
SELECTION-SCREEN COMMENT 40(13) TEXT-035.
SELECTION-SCREEN END OF LINE.
SELECTION-SCREEN SKIP.
PARAMETERS:
* Parameter holding Input File name
P_FILE LIKE RLGRAP-FILENAME
OBLIGATORY
LOWER CASE
DEFAULT 'C:\'
MODIF ID G1,
P_FILE1 LIKE RLGRAP-FILENAME
OBLIGATORY
LOWER CASE
DEFAULT '/celestica/interface/corp/in/work/'
MODIF ID G2,
* Parameter specifying Mode of calling the Transaction.
P_MODE DEFAULT 'N' OBLIGATORY,
* Check box used to test the input file.
P_TEST AS CHECKBOX DEFAULT 'X',
* Parameter holding Filename for holding Input File Errors
P_IPERR LIKE RLGRAP-FILENAME
OBLIGATORY
LOWER CASE
DEFAULT 'C:\'
MODIF ID G1,
P_IPERR1 LIKE RLGRAP-FILENAME
OBLIGATORY
LOWER CASE
DEFAULT '/celestica/interface/corp/in/work/047_Err.txt'
MODIF ID G2.
SELECTION-SCREEN END OF BLOCK B2.
* AT Selection Screen Events *
* Loop the screen to activate relative paths
AT SELECTION-SCREEN OUTPUT.
LOOP AT SCREEN.
IF RB_SERVE = C_TRUE AND SCREEN-GROUP1 = 'G1'.
SCREEN-OUTPUT = 0.
SCREEN-ACTIVE = 0.
SCREEN-INPUT = 0.
ELSEIF RB_LOCAL = C_TRUE AND SCREEN-GROUP1 = 'G2'.
SCREEN-OUTPUT = 0.
SCREEN-ACTIVE = 0.
SCREEN-INPUT = 0.
ENDIF.
MODIFY SCREEN.
ENDLOOP.
AT SELECTION-SCREEN ON BLOCK B2.
* Checking Access Authorization for the user
CALL FUNCTION 'ZU_DATA_ACCESS_AUTH_CHECK'
EXPORTING
ACTVT = C_16
P_BUKRS = P_BUKRS
TABLES
S_WERKS = S_WERKS
S_EKORG = S_EKORG
EXCEPTIONS
BUKRS_FAILED = 1
VKORG_FAILED = 2
VTWEG_FAILED = 3
EKORG_FAILED = 4
WERKS_FAILED = 5
LGNUM_FAILED = 6
OTHERS = 7.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
AT SELECTION-SCREEN ON P_BUKRS.
IF NOT P_BUKRS IS INITIAL.
SELECT SINGLE BUKRS INTO T001
FROM T001
WHERE BUKRS EQ P_BUKRS.
IF SY-SUBRC NE 0.
MESSAGE I000 WITH TEXT-089.
STOP.
ENDIF.
ENDIF.
AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_FILE.
* Search Help to select Input File path.
PERFORM GET_FILE_NAME USING P_FILE.
* Check for the existence of the file.
IF RB_LOCAL EQ C_TRUE.
CALL FUNCTION 'TMP_GUI_GET_FILE_EXIST'
EXPORTING
FNAME = P_FILE
IMPORTING
EXIST = V_EXIST
ISDIR = V_ISDIR
EXCEPTIONS
FILEINFO_ERROR = 1
OTHERS = 2.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
IF V_ISDIR IS INITIAL.
IF V_EXIST IS INITIAL.
MESSAGE I000 WITH TEXT-018.
STOP.
ENDIF.
ELSEIF V_ISDIR EQ C_TRUE.
MESSAGE I000 WITH TEXT-068.
STOP.
ENDIF.
ENDIF.
AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_IPERR.
* Search Help to select Input Error File path.
PERFORM GET_FILE_NAME USING P_IPERR.
AT SELECTION-SCREEN.
* Validate Transaction Mode
IF P_MODE <> C_BACKGROUND AND
P_MODE <> C_FOREGROUND AND
P_MODE <> C_ERRORS.
MESSAGE I000 WITH TEXT-034.
STOP.
ENDIF.
START-OF-SELECTION.
* Get the Input File Data
V_FILENAME = P_FILE.
PERFORM UPLOAD_FLATFILE_DATA TABLES I_RECORD
USING V_FILENAME.
* Sorting the data by all fields
SORT I_RECORD.
* Ensuring the padding of the empty spaces before the vendor No
CLEAR WA_RECORD.
LOOP AT I_RECORD INTO WA_RECORD.
CALL FUNCTION 'CONVERSION_EXIT_ALPHA_INPUT'
EXPORTING
INPUT = WA_RECORD-LIFNR
IMPORTING
OUTPUT = WA_RECORD-LIFNR.
MODIFY I_RECORD FROM WA_RECORD
INDEX SY-TABIX
TRANSPORTING LIFNR.
CLEAR WA_RECORD.
ENDLOOP.
* Input file validation
PERFORM VALIDATE_FLATFILE_DATA.
IF P_TEST = C_TRUE.
IF I_ERR_REC[] IS INITIAL.
MESSAGE I000 WITH TEXT-032.
STOP.
ELSE.
* Display all the error records at the input level.
PERFORM DISPLAY_INPERR_RECORDS.
* Download Error File
PERFORM DOWNLOAD_ERROR_FILE.
ENDIF.
ELSE.
* Build BDC Data
PERFORM BUILD_BDC_DATA.
* Download Error File
PERFORM DOWNLOAD_ERROR_FILE.
* Display the status report.
PERFORM DISPLAY_PROCESSED_RECORDS.
ENDIF.
END-OF-SELECTION.
REFRESH: I_RECORD,
I_ERR_REC,
I_LOEKZ,
I_MATNR,
I_ZMVXREF,
I_LFA1,
I_T024E,
I_FIELDCAT,
I_LISTHEADER,
I_ALV_EVENT,
I_SORT,
I_BDCDATA,
I_MESSTAB,
I_STR1.
FREE: I_RECORD,
I_ERR_REC,
I_LOEKZ,
I_MATNR,
I_ZMVXREF,
I_LFA1,
I_T024E,
I_FIELDCAT,
I_LISTHEADER,
I_ALV_EVENT,
I_SORT,
I_BDCDATA,
I_MESSTAB,
I_STR1.
*& Form GET_file_name
* Fetches the file and path from the presentation system
* --> p1 Path along with the file name
FORM GET_FILE_NAME USING L_FILE LIKE RLGRAP-FILENAME.
CALL FUNCTION 'WS_FILENAME_GET'
EXPORTING
MASK = ',*.TXT,*.txt.'
MODE = 'O'
TITLE = TEXT-011
IMPORTING
FILENAME = L_FILE
EXCEPTIONS
INV_WINSYS = 1
NO_BATCH = 2
SELECTION_CANCEL = 3
SELECTION_ERROR = 4
OTHERS = 5.
CASE SY-SUBRC.
WHEN 1.
MESSAGE I000 WITH TEXT-084.
STOP.
WHEN 2.
MESSAGE I000 WITH TEXT-085.
STOP.
WHEN 3.
MESSAGE I000 WITH TEXT-086.
STOP.
WHEN 4.
MESSAGE I000 WITH TEXT-087.
STOP.
ENDCASE.
ENDFORM. " GET_file_name
*& Form upload_flatfile_data
* Uploading data from Flat File
FORM UPLOAD_FLATFILE_DATA
TABLES I_L_RECORD STRUCTURE WA_RECORD
USING L_FILENAME TYPE STRING.
DATA WA_L_RECORD TYPE T_RECORD.
* Upload the Flat file data
IF RB_LOCAL EQ C_TRUE. "File is on the Local System
CALL FUNCTION 'GUI_UPLOAD'
EXPORTING
FILENAME = L_FILENAME
FILETYPE = 'ASC'
HAS_FIELD_SEPARATOR = 'X'
TABLES
DATA_TAB = I_L_RECORD
EXCEPTIONS
FILE_OPEN_ERROR = 1
FILE_READ_ERROR = 2
NO_BATCH = 3
GUI_REFUSE_FILETRANSFER = 4
INVALID_TYPE = 5
NO_AUTHORITY = 6
UNKNOWN_ERROR = 7
BAD_DATA_FORMAT = 8
HEADER_NOT_ALLOWED = 9
SEPARATOR_NOT_ALLOWED = 10
HEADER_TOO_LONG = 11
UNKNOWN_DP_ERROR = 12
ACCESS_DENIED = 13
DP_OUT_OF_MEMORY = 14
DISK_FULL = 15
DP_TIMEOUT = 16
OTHERS = 17.
CASE SY-SUBRC.
WHEN 0.
DESCRIBE TABLE I_L_RECORD LINES V_LINE.
IF V_LINE EQ 0.
MESSAGE I000 WITH TEXT-065.
STOP.
ENDIF.
WHEN 1.
MESSAGE I000 WITH TEXT-068.
STOP.
WHEN 2.
MESSAGE I000 WITH TEXT-069.
STOP.
WHEN 3.
MESSAGE I000 WITH TEXT-070.
STOP.
WHEN 4.
MESSAGE I000 WITH TEXT-071.
STOP.
WHEN 5.
MESSAGE I000 WITH TEXT-072.
STOP.
WHEN 6.
MESSAGE I000 WITH TEXT-073.
STOP.
WHEN 7.
MESSAGE I000 WITH TEXT-074.
STOP.
WHEN 8.
MESSAGE I000 WITH TEXT-075.
STOP.
WHEN 9.
MESSAGE I000 WITH TEXT-076.
STOP.
WHEN 10.
MESSAGE I000 WITH TEXT-077.
STOP.
WHEN 11.
MESSAGE I000 WITH TEXT-078.
STOP.
WHEN 12.
MESSAGE I000 WITH TEXT-079.
STOP.
WHEN 13.
MESSAGE I000 WITH TEXT-080.
STOP.
WHEN 14.
MESSAGE I000 WITH TEXT-081.
STOP.
WHEN 15.
MESSAGE I000 WITH TEXT-082.
STOP.
WHEN 16.
MESSAGE I000 WITH TEXT-083.
STOP.
ENDCASE.
CLEAR V_LINE.
ELSEIF RB_SERVE EQ C_TRUE. "File is on the Application Server
P_MODE = C_BACKGROUND.
OPEN DATASET P_FILE1 FOR INPUT IN TEXT MODE.
CHECK SY-SUBRC EQ C_SUCCESS.
CLEAR WA_STR1.
DO.
READ DATASET P_FILE1 INTO WA_STR1.
IF SY-SUBRC <> 0. " NE SUCCESS.
EXIT.
ELSEIF SY-SUBRC EQ C_SUCCESS.
APPEND WA_STR1 TO I_STR1.
CLEAR WA_STR1.
ENDIF. " ENDIF on SY-SUBRC 0 Check.
ENDDO. " ENDDO
DELETE I_STR1 WHERE SLINE EQ ' '.
DESCRIBE TABLE I_STR1 LINES V_LINE.
IF V_LINE EQ 0.
MESSAGE S000 WITH TEXT-065.
STOP.
ENDIF.
LOOP AT I_STR1 INTO WA_STR1.
CLEAR: WA_L_RECORD.
SPLIT WA_STR1-SLINE AT V_STR
INTO WA_L_RECORD-LIFNR
WA_L_RECORD-EVART
WA_L_RECORD-EKORG
WA_L_RECORD-EKGRP
WA_L_RECORD-WERKS
WA_L_RECORD-LGORT
WA_L_RECORD-KDATB
WA_L_RECORD-KDATE
WA_L_RECORD-ZTERM
WA_L_RECORD-KTWRT
WA_L_RECORD-EPSTP
WA_L_RECORD-EMATN
WA_L_RECORD-KTMNG
WA_L_RECORD-NETPR
WA_L_RECORD-PEINH
WA_L_RECORD-BPRME
WA_L_RECORD-IDNLF
WA_L_RECORD-WEBRE
WA_L_RECORD-MEPRF
WA_L_RECORD-LTEX1
WA_L_RECORD-DATAB
WA_L_RECORD-DATBI
WA_L_RECORD-KSCHL
WA_L_RECORD-KBETR
WA_L_RECORD-KONWA
WA_L_RECORD-KPEIN
WA_L_RECORD-KMEIN
WA_L_RECORD-KSTBM
WA_L_RECORD-KBETR_01
WA_L_RECORD-DEL_FLAG
WA_L_RECORD-ERR_MSG.
APPEND WA_L_RECORD TO I_L_RECORD.
CLEAR: WA_L_RECORD,
WA_STR1.
ENDLOOP.
REFRESH I_STR1.
CLOSE DATASET P_FILE1.
ENDIF.
ENDFORM.
*& Form BDC_DYNPRO
* Data populated into i_bdcdata table for program
FORM BDC_DYNPRO USING PROGRAM DYNPRO.
CLEAR WA_BDCDATA.
WA_BDCDATA-PROGRAM = PROGRAM.
WA_BDCDATA-DYNPRO = DYNPRO.
WA_BDCDATA-DYNBEGIN = C_TRUE.
APPEND WA_BDCDATA TO I_BDCDATA.
ENDFORM.
*& Form BDC_FIELD
* Data populated into i_bdcdata table for fields
FORM BDC_FIELD USING FNAM FVAL.
CLEAR WA_BDCDATA.
WA_BDCDATA-FNAM = FNAM.
WA_BDCDATA-FVAL = FVAL.
APPEND WA_BDCDATA TO I_BDCDATA.
ENDFORM.
*& Form convert_date
* Converting the data from the file format to mm/dd/yyyy format
* <--P_wa_record_kdatb Source Date
* <--p_l_conv_date Target Date
FORM CONVERT_DATE USING L_DATE
L_TAR_DATE.
CONCATENATE L_DATE+0(2)
L_DATE+3(2)
L_DATE+6(4)
INTO L_TAR_DATE.
ENDFORM. " convert_date
*& Form validate_flatfile_data
* Validating the input file
FORM VALIDATE_FLATFILE_DATA.
DATA: L_TODAY LIKE SY-DATUM,
L_STARTDATE_C LIKE SY-DATUM,
L_ENDDATE_C LIKE SY-DATUM,
L_ENDDATE_C1 LIKE SY-DATUM,
L_STARTDATE_C1 LIKE SY-DATUM,
L_STARTDATE(8),
L_ENDDATE(8).
* Fetch indicator for all records on the material, plant & storage
* location combination.
IF NOT I_RECORD[] IS INITIAL.
REFRESH I_LOEKZ.
SELECT EMATN " Material Number
WERKS " Plant
LGORT " Storage Location
BSTYP " Purchasing Document Category
LOEKZ " Deletion indicator
INTO TABLE I_LOEKZ
FROM EKPO
FOR ALL ENTRIES IN I_RECORD
WHERE EMATN = I_RECORD-EMATN
AND WERKS = I_RECORD-WERKS
AND LGORT = I_RECORD-LGORT
AND BSTYP = C_BSTYP
AND LOEKZ = C_LOEKZ_MARKED.
IF SY-SUBRC EQ 0.
SORT I_LOEKZ BY EMATN WERKS LGORT BSTYP LOEKZ.
ENDIF.
* Fetching Plants for all entries in the selection screen
REFRESH I_T001W.
SELECT WERKS "Plant
INTO TABLE I_T001W
FROM T001W
WHERE WERKS IN S_WERKS.
IF SY-SUBRC EQ 0.
SORT I_T001W BY WERKS.
ENDIF.
* Fetching materials for the plants listed in flat file
REFRESH I_MATNR.
SELECT MATNR " Material Number
INTO TABLE I_MATNR
FROM MARC
FOR ALL ENTRIES IN I_RECORD
WHERE WERKS = I_RECORD-WERKS.
IF SY-SUBRC EQ 0.
SORT I_MATNR BY MATNR.
ENDIF.
* Fetching Company Codes for repective Purchase Organizations
REFRESH I_T024E.
SELECT EKORG " Purchase Organization
BUKRS " Company Code
INTO TABLE I_T024E
FROM T024E
WHERE EKORG IN S_EKORG.
IF SY-SUBRC EQ 0.
SORT I_T024E BY EKORG.
ENDIF.
* Fetching SAP Data using Legacy Data.
REFRESH I_ZMVXREF.
SELECT D_ALTKN
D_BUKRS
M_ALTKN
INTO TABLE I_ZMVXREF
FROM ZMVXREF
FOR ALL ENTRIES IN I_RECORD
WHERE D_ALTKN = I_RECORD-LIFNR.
IF SY-SUBRC EQ 0.
SORT I_ZMVXREF BY D_ALTKN D_BUKRS.
ENDIF.
* Fetching Vendors from LFA1
IF NOT I_ZMVXREF[] IS INITIAL.
REFRESH I_LFA1.
SELECT LIFNR
INTO TABLE I_LFA1
FROM LFA1
FOR ALL ENTRIES IN I_ZMVXREF
WHERE LIFNR = I_ZMVXREF-M_ALTKN.
IF SY-SUBRC EQ 0.
SORT I_LFA1 BY LIFNR.
ENDIF.
ENDIF.
* Start Validating the flat file
CLEAR: WA_RECORD,
WA_T024E,
WA_ZMVXREF,
WA_LFA1,
WA_LOEKZ,
WA_MATNR.
LOOP AT I_RECORD INTO WA_RECORD.
L_TODAY = SY-DATUM.
L_STARTDATE = WA_RECORD-KDATB.
L_ENDDATE = WA_RECORD-KDATE.
IF WA_RECORD-DEL_FLAG IS INITIAL.
READ TABLE I_T001W INTO WA_T001W
WITH KEY WERKS = WA_RECORD-WERKS
BINARY SEARCH.
IF SY-SUBRC EQ 0.
* Cross-Reference check performed for the given Vendors
READ TABLE I_T024E INTO WA_T024E
WITH KEY EKORG = WA_RECORD-EKORG
BINARY SEARCH.
IF SY-SUBRC NE 0.
V_CROSS_REFERENCE_ERROR = C_VEN_ERR3.
ELSE.
READ TABLE I_ZMVXREF INTO WA_ZMVXREF
WITH KEY D_ALTKN = WA_RECORD-LIFNR
D_BUKRS = P_BUKRS
BINARY SEARCH.
IF SY-SUBRC EQ 0.
READ TABLE I_LFA1 INTO WA_LFA1
WITH KEY LIFNR = WA_ZMVXREF-M_ALTKN
BINARY SEARCH.
IF SY-SUBRC EQ 0.
V_CROSS_REFERENCE_ERROR = C_VEN_SUCS.
ELSE.
V_CROSS_REFERENCE_ERROR = C_VEN_ERR2.
ENDIF.
ELSE.
V_CROSS_REFERENCE_ERROR = C_VEN_ERR1.
ENDIF.
ENDIF.
* Legacy Vendor could not be mapped
IF V_CROSS_REFERENCE_ERROR EQ C_VEN_ERR1.
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES. "Inp.file err. occurd
WA_RECORD-DEL_FLAG = C_TRUE.
WA_RECORD-ERR_MSG = TEXT-007.
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR.
* Legacy Vendor is mapped but the obtained SAP vendor doesn't exist.
ELSEIF V_CROSS_REFERENCE_ERROR EQ C_VEN_ERR2.
* Inp.file err. occurd
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-DEL_FLAG = C_TRUE.
WA_RECORD-ERR_MSG = TEXT-008.
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR.
* Purchase Organization doesn't exist in T024E.
ELSEIF V_CROSS_REFERENCE_ERROR EQ C_VEN_ERR3.
* Inp.file err. occurd
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-DEL_FLAG = C_TRUE.
WA_RECORD-ERR_MSG = TEXT-014.
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE EKORG = WA_RECORD-EKORG.
* Vendor is mapped and validated successfully
ELSEIF V_CROSS_REFERENCE_ERROR EQ C_VEN_SUCS.
* Checking for the deletion indicator for that record
CONCATENATE WA_RECORD-KDATB+6(4)
WA_RECORD-KDATB+3(2)
WA_RECORD-KDATB+0(2)
INTO
L_STARTDATE.
MOVE L_STARTDATE TO L_STARTDATE_C.
CONCATENATE WA_RECORD-KDATB+6(4)
WA_RECORD-KDATB+0(2)
WA_RECORD-KDATB+3(2)
INTO
L_STARTDATE_C1.
CONCATENATE WA_RECORD-KDATE+6(4)
WA_RECORD-KDATE+3(2)
WA_RECORD-KDATE+0(2)
INTO
L_ENDDATE.
MOVE L_ENDDATE TO L_ENDDATE_C.
CONCATENATE WA_RECORD-KDATE+6(4)
WA_RECORD-KDATE+0(2)
WA_RECORD-KDATE+3(2)
INTO
L_ENDDATE_C1.
READ TABLE I_LOEKZ INTO WA_LOEKZ WITH KEY
EMATN = WA_RECORD-EMATN
WERKS = WA_RECORD-WERKS
LGORT = WA_RECORD-LGORT
BINARY SEARCH.
IF SY-SUBRC EQ 0.
* Inpfle err.occured
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-ERR_MSG = TEXT-003.
WA_RECORD-DEL_FLAG = C_TRUE. "marking the record
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR
AND EVART = WA_RECORD-EVART
AND EKORG = WA_RECORD-EKORG
AND EKGRP = WA_RECORD-EKGRP
AND WERKS = WA_RECORD-WERKS
AND LGORT = WA_RECORD-LGORT
AND KDATB = WA_RECORD-KDATB
AND KDATE = WA_RECORD-KDATE
AND ZTERM = WA_RECORD-ZTERM
AND KTWRT = WA_RECORD-KTWRT
AND EPSTP = WA_RECORD-EPSTP
AND EMATN = WA_RECORD-EMATN.
* Validating the Purchasing Organization for Blank/Null
ELSEIF WA_RECORD-EKORG IS INITIAL.
* Inpfle err.occured
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-ERR_MSG = TEXT-010.
WA_RECORD-DEL_FLAG = C_TRUE.
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR
AND EVART = WA_RECORD-EVART
AND EKORG = WA_RECORD-EKORG
AND EKGRP = WA_RECORD-EKGRP
AND WERKS = WA_RECORD-WERKS
AND LGORT = WA_RECORD-LGORT
AND KDATB = WA_RECORD-KDATB
AND KDATE = WA_RECORD-KDATE
AND ZTERM = WA_RECORD-ZTERM
AND KTWRT = WA_RECORD-KTWRT
AND EPSTP = WA_RECORD-EPSTP
AND EMATN = WA_RECORD-EMATN.
* Validating the Plant for Blank/Null
ELSEIF WA_RECORD-WERKS IS INITIAL.
* Inpfle err.occured
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-ERR_MSG = TEXT-039.
WA_RECORD-DEL_FLAG = C_TRUE.
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR
AND EVART = WA_RECORD-EVART
AND EKORG = WA_RECORD-EKORG
AND EKGRP = WA_RECORD-EKGRP
AND WERKS = WA_RECORD-WERKS
AND LGORT = WA_RECORD-LGORT
AND KDATB = WA_RECORD-KDATB
AND KDATE = WA_RECORD-KDATE
AND ZTERM = WA_RECORD-ZTERM
AND KTWRT = WA_RECORD-KTWRT
AND EPSTP = WA_RECORD-EPSTP
AND EMATN = WA_RECORD-EMATN.
* Validating the Contract Validity Start Date
ELSEIF L_STARTDATE_C1 GT L_TODAY. "#EC PORTABLE
* Inpfle err.occured
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-ERR_MSG = TEXT-004.
WA_RECORD-DEL_FLAG = C_TRUE. "marking the record
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR
AND EVART = WA_RECORD-EVART
AND EKORG = WA_RECORD-EKORG
AND EKGRP = WA_RECORD-EKGRP
AND WERKS = WA_RECORD-WERKS
AND LGORT = WA_RECORD-LGORT
AND KDATB = WA_RECORD-KDATB.
* Validating the Contract Validity End Date
ELSEIF L_ENDDATE_C1 LE L_TODAY. "#EC PORTABLE
* Inpfle err.ocrd
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
WA_RECORD-ERR_MSG = TEXT-005.
WA_RECORD-DEL_FLAG = C_TRUE. "marking the record
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR
AND EVART = WA_RECORD-EVART
AND EKORG = WA_RECORD-EKORG
AND EKGRP = WA_RECORD-EKGRP
AND WERKS = WA_RECORD-WERKS
AND LGORT = WA_RECORD-LGORT
AND KDATB = WA_RECORD-KDATB
AND KDATE = WA_RECORD-KDATE.
* Checking for Material under the Plant for Agreement Type 'WK'
ELSEIF WA_RECORD-EVART = C_WK.
READ TABLE I_MATNR INTO WA_MATNR
WITH KEY MATNR = WA_RECORD-EMATN
BINARY SEARCH.
IF SY-SUBRC NE 0.
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES. "Inpfle err.ocrd
WA_RECORD-ERR_MSG = TEXT-006.
WA_RECORD-DEL_FLAG = C_TRUE. "marking the record
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE LIFNR = WA_RECORD-LIFNR
AND EVART = WA_RECORD-EVART
AND EKORG = WA_RECORD-EKORG
AND EKGRP = WA_RECORD-EKGRP
AND WERKS = WA_RECORD-WERKS
AND LGORT = WA_RECORD-LGORT
AND KDATB = WA_RECORD-KDATB
AND KDATE = WA_RECORD-KDATE
AND ZTERM = WA_RECORD-ZTERM
AND KTWRT = WA_RECORD-KTWRT
AND EPSTP = WA_RECORD-EPSTP
AND EMATN = WA_RECORD-EMATN.
ENDIF.
ENDIF. " checking of deletion indicator
ENDIF. " checking for success of vendor cross reference
ELSE.
V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES. "Inpfle err.ocrd
WA_RECORD-ERR_MSG = TEXT-041.
WA_RECORD-DEL_FLAG = C_TRUE. "marking the record
MODIFY I_RECORD FROM WA_RECORD
TRANSPORTING DEL_FLAG
ERR_MSG
WHERE WERKS = WA_RECORD-WERKS.
ENDIF. " Plant checked to selection screen
ENDIF. " the records for which del_flag is initial
CLEAR: WA_RECORD,
WA_T024E,
WA_ZMVXREF,
WA_LFA1,
WA_LOEKZ,
WA_MATNR,
L_TODAY,
L_STARTDATE_C,
L_ENDDATE_C,
L_STARTDATE,
L_ENDDATE.
ENDLOOP.
LOOP AT I_RECORD INTO WA_RECORD.
IF WA_RECORD-DEL_FLAG = C_TRUE.
APPEND WA_RECORD TO I_ERR_REC.
CLEAR WA_RECORD.
ENDIF.
ENDLOOP.
ELSE.
MESSAGE E000 WITH TEXT-013. " no records in the flat file
STOP.
ENDIF.
ENDFORM. " validate_flatfile_data
*& Form DOWNLOAD_ERROR_FILE
* Downloads all records along with the records encountering the
* input file validation error
FORM DOWNLOAD_ERROR_FILE.
DATA L_ISDIR TYPE C.
IF V_INPUTERROR_FLAG = C_INPUTERROR_FLAG_YES.
V_FILENAME = P_IPERR.
* Check for the existence of the file.
IF RB_LOCAL EQ C_TRUE.
CALL FUNCTION 'TMP_GUI_GET_FILE_EXIST'
EXPORTING
FNAME = P_IPERR
IMPORTING
ISDIR = L_ISDIR
EXCEPTIONS
FILEINFO_ERROR = 1
OTHERS = 2.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
IF L_ISDIR EQ C_TRUE.
MESSAGE I000 WITH TEXT-088.
STOP.
ENDIF.
ENDIF.
IF RB_LOCAL EQ C_TRUE.
* Download the Input Error File.
CALL FUNCTION 'GUI_DOWNLOAD'
EXPORTING
FILENAME = V_FILENAME
FILETYPE = 'ASC'
WRITE_FIELD_SEPARATOR = '#'
TABLES
DATA_TAB = I_ERR_REC
EXCEPTIONS
FILE_WRITE_ERROR = 1
NO_BATCH = 2
GUI_REFUSE_FILETRANSFER = 3
INVALID_TYPE = 4
NO_AUTHORITY = 5
UNKNOWN_ERROR = 6
HEADER_NOT_ALLOWED = 7
SEPARATOR_NOT_ALLOWED = 8
FILESIZE_NOT_ALLOWED = 9
HEADER_TOO_LONG = 10
DP_ERROR_CREATE = 11
DP_ERROR_SEND = 12
DP_ERROR_WRITE = 13
UNKNOWN_DP_ERROR = 14
ACCESS_DENIED = 15
DP_OUT_OF_MEMORY = 16
DISK_FULL = 17
DP_TIMEOUT = 18
FILE_NOT_FOUND = 19
DATAPROVIDER_EXCEPTION = 20
CONTROL_FLUSH_ERROR = 21
OTHERS = 22.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
ELSEIF RB_SERVE EQ C_TRUE.
OPEN DATASET P_IPERR1 FOR OUTPUT IN TEXT MODE.
CHECK SY-SUBRC EQ 0.
CLEAR WA_ERR_REC.
LOOP AT I_ERR_REC INTO WA_ERR_REC.
IF WA_ERR_REC-DEL_FLAG = C_TRUE.
TRANSFER WA_ERR_REC TO P_IPERR1.
ENDIF.
CLEAR WA_ERR_REC.
ENDLOOP.
CLOSE DATASET P_IPERR1.
ENDIF.
ENDIF.
ENDFORM. " DOWNLOAD_ERROR_FILE
*& Form BUILD_BDC_DATA
* Populates BDC for all the fields neccessary for Open Contract Creation
FORM BUILD_BDC_DATA.
DATA: L_MAT_INDEX TYPE I,
L_CON_INDEX TYPE I,
L_SCA_INDEX TYPE I.
CLEAR WA_BDCDATA.
REFRESH: I_BDCDATA,
I_MESSTAB.
* Processing the bdc
CLEAR: WA_RECORD,
WA_RECORDPREV,
VEN_FLAG,
MAT_FLAG.
LOOP AT I_RECORD INTO WA_RECORD.
* Checks for the del_flag of the record.
IF WA_RECORD-DEL_FLAG EQ C_TRUE
OR WA_RECORD-DEL_FLAG EQ C_STRUE.
CLEAR WA_RECORD.
CONTINUE.
ELSE.
IF WA_RECORDPREV-LIFNR NE WA_RECORD-LIFNR
OR WA_RECORDPREV-EVART NE WA_RECORD-EVART
OR WA_RECORDPREV-EKORG NE WA_RECORD-EKORG
OR WA_RECORDPREV-EKGRP NE WA_RECORD-EKGRP
OR WA_RECORDPREV-WERKS NE WA_RECORD-WERKS
OR WA_RECORDPREV-LGORT NE WA_RECORD-LGORT
OR WA_RECORDPREV-KDATB NE WA_RECORD-KDATB
OR WA_RECORDPREV-KDATE NE WA_RECORD-KDATE
OR WA_RECORDPREV-ZTERM NE WA_RECORD-ZTERM
OR WA_RECORDPREV-KTWRT NE WA_RECORD-KTWRT.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0200'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RM06E-LGORT'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
* Cross-Reference check performed for the given Vendors
CLEAR WA_T024E.
READ TABLE I_T024E INTO WA_T024E
WITH KEY EKORG = WA_RECORD-EKORG
BINARY SEARCH.
IF SY-SUBRC EQ 0.
CLEAR WA_ZMVXREF.
READ TABLE I_ZMVXREF INTO WA_ZMVXREF
WITH KEY D_ALTKN = WA_RECORD-LIFNR
D_BUKRS = P_BUKRS
BINARY SEARCH.
IF SY-SUBRC EQ 0.
PERFORM BDC_FIELD USING 'EKKO-LIFNR'
WA_ZMVXREF-M_ALTKN.
ENDIF.
CLEAR WA_ZMVXREF.
ENDIF.
CLEAR WA_T024E.
PERFORM BDC_FIELD USING 'RM06E-EVART'
WA_RECORD-EVART.
PERFORM BDC_FIELD USING 'EKKO-EKORG'
WA_RECORD-EKORG.
PERFORM BDC_FIELD USING 'EKKO-EKGRP'
WA_RECORD-EKGRP.
PERFORM BDC_FIELD USING 'RM06E-WERKS'
WA_RECORD-WERKS.
PERFORM BDC_FIELD USING 'RM06E-LGORT'
WA_RECORD-LGORT.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0201'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'EKKO-KTWRT'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=AB'.
PERFORM CONVERT_DATE USING WA_RECORD-KDATB V_CONV_DATE.
PERFORM BDC_FIELD USING 'EKKO-KDATB'
V_CONV_DATE.
PERFORM CONVERT_DATE USING WA_RECORD-KDATE V_CONV_DATE.
PERFORM BDC_FIELD USING 'EKKO-KDATE'
V_CONV_DATE.
PERFORM BDC_FIELD USING 'EKKO-ZTERM'
WA_RECORD-ZTERM.
PERFORM BDC_FIELD USING 'EKKO-KTWRT'
WA_RECORD-KTWRT.
VEN_FLAG = 1.
L_MAT_INDEX = 1. "index for table-control of material
ENDIF.
* "first check for itemline
IF WA_RECORDPREV-EPSTP NE WA_RECORD-EPSTP
OR WA_RECORDPREV-EMATN NE WA_RECORD-EMATN
OR WA_RECORDPREV-KTMNG NE WA_RECORD-KTMNG
OR WA_RECORDPREV-NETPR NE WA_RECORD-NETPR
OR WA_RECORDPREV-PEINH NE WA_RECORD-PEINH
OR WA_RECORDPREV-BPRME NE WA_RECORD-BPRME
OR WA_RECORDPREV-IDNLF NE WA_RECORD-IDNLF
OR WA_RECORDPREV-WEBRE NE WA_RECORD-WEBRE
OR WA_RECORDPREV-MEPRF NE WA_RECORD-MEPRF
OR WA_RECORDPREV-LTEX1 NE WA_RECORD-LTEX1
OR VEN_FLAG EQ 1.
V_IND = L_MAT_INDEX.
IF V_IND GT 1.
V_IND = 2.
ENDIF.
CONCATENATE 'RM06E-EVRTP(' V_IND ')' INTO V_EVRTP1.
CONCATENATE 'RM06E-EPSTP(' V_IND ')' INTO V_EPSTP1.
CONCATENATE 'EKPO-EMATN(' V_IND ')' INTO V_EMATN1.
CONCATENATE 'EKPO-KTMNG(' V_IND ')' INTO V_KTMNG1.
CONCATENATE 'EKPO-NETPR(' V_IND ')' INTO V_NETPR1.
CONCATENATE 'EKPO-PEINH(' V_IND ')' INTO V_PEINH1.
CONCATENATE 'EKPO-BPRME(' V_IND ')' INTO V_BPRME1.
CONCATENATE 'RM06E-TCSELFLAG(' V_IND ')' INTO V_TCSELFLAG1.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0220'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=NP'.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0220'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
V_EVRTP1.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=DETA'.
PERFORM BDC_FIELD USING V_EPSTP1
WA_RECORD-EPSTP.
PERFORM BDC_FIELD USING V_EMATN1
WA_RECORD-EMATN.
PERFORM BDC_FIELD USING V_KTMNG1
WA_RECORD-KTMNG.
PERFORM BDC_FIELD USING V_NETPR1
WA_RECORD-NETPR.
PERFORM BDC_FIELD USING V_PEINH1
WA_RECORD-PEINH.
PERFORM BDC_FIELD USING V_BPRME1
WA_RECORD-BPRME.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0211'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'EKPO-WEBRE'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=DETZ'.
PERFORM BDC_FIELD USING 'EKPO-IDNLF'
WA_RECORD-IDNLF.
TRANSLATE WA_RECORD-EVART TO UPPER CASE.
IF WA_RECORD-EVART EQ C_WK.
PERFORM BDC_FIELD USING 'EKPO-WEBRE' 'X'.
ENDIF.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0212'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'EKPO-MEPRF'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=TXP'.
PERFORM BDC_FIELD USING 'EKPO-MEPRF'
WA_RECORD-MEPRF.
IF NOT WA_RECORD-LTEX1 IS INITIAL. "NE space.
PERFORM BDC_DYNPRO USING 'SAPMM06E' '0106'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RM06E-SELKZ(02)'.
PERFORM BDC_FIELD -
Data Transfer / Communication between Live Applications
Gurus,
I am basically an E-Business Sutie Developer. This is my first experience posting questions in Application and Architecture community.
Please read the following and let me know if this is the correct thread to post this question also it would be appreciable if you could provide suggestions / solutions for my question.
Q:
We are on E-Bus Suite 11.5.9 with custom applications built using Oracle Forms. Recently one of our department decided to buy a custom software to replace one of the application. There are other applications which we built still running in E-Bus Suite. The custom software is based on .NET and SQL Server. We at IT rite now researching how to data transfer between our existing applications and the new software. They both were in different platforms.
This is a new initiative for us because all these years we use to work on oracle applications and this is the first time where we have to go away from our forte. This could be simple for people with experience in related field but this is challenging for us.
Your views and suggestions are highly valuable.
Thank You.
Karthik.Hi,
Thank You for the reply. Below are the notes from person who already did some of the research. I am not sure whether to go with the below mentioned or to research more...
Below are the following options to load data from SQL server to Oracle, I read limited on each option. See if something convince you and I will explore more on that option..
1. Linked Servers: Linked Servers can be setup on the SQL server instance and then data can be pushed out to the Oracle schema.
a. Limitation in terms of data type supported by provider/ODBC driver used for creating
linked servers, Performance good for decent size tables
b. Advantage: All SLQ based
http://msdn.microsoft.com/en-us/library/ms188279.aspx
http://www.codeproject.com/Articles/35943/How-to-Config-Linked-Servers-in-a-Minute
2. Oracle Hetereogeneous services: This is Oracle’s answer to Microsoft’s linked servers. By setting it up,
this can be used to pull data from SQL server db and load to Oracle.
Same limitations and advantages as 1.
http://www.csee.umbc.edu/portal/help/oracle8/server.815/a67784/hs_ch6.htm
3. DTS (Data Trnasformation Services) or SSIS (SQL Server Integration Services) : Microsoft SQL server 2000 comes
with DTS and SQL 2005 with SSIS.
SSIS is robust than DTS for this job and can be used to load data up in the Oracle Schema.
These tools can be used to provide a real ETL process for data loading.
4. Scripting Framework: Scripts can be written to bcp data from a SQL servere db and then use SQL Loader to
load data to oracle schema
5. Third Party tools: A couple of third party tools also provide these options.
----------------------------------------------------------------------------------------------------------------------------------------------------------- -
Candidate Data transfer from E-Recruiting System to HR system for New Hiring.
Hi All,
Hope everyone doing in good Spirit.
We are implementing E-Recruiting as Standalone for one of our client.
Can any please help me in regards with Data transfer from E-Rec System to HR System for hiring once the candidate has been successfully completed recruiting process.
You inputs are highly appreciable.
Thank you.
Sekhar.Hello Sekhar,
there are three different scenarios for transferring the data of an external candidate to the HR core for hiring.
the easiest and most commonly used is the RFC connection. When creating an activity of category data transfer the data of the candidate is transferred from eRec to HR core. There it is stored in table T752F. Then you can run transaction PA48. There you can select the candidate and run a hiring action. This is the same action like in PA40 only the system will preset the fields with the values from eRec (similar to batch input).
Instead of using the RFC solution you can transfer the data using PI (this can be activated using a switch in T77S0). To be honest none of my customers is using this. Either they had no PI server at all or they did not use it for eRec
The third was delivered with a business function HCM_HIRE_INT_CI_1. This is based on HCM processes and forms and targeted towards customers using Talent Management Core (e.g. data for education and work experience is transferred into the TM Core infotypes 740X as contrary to the hr core standard infotypes 0022 and 0023 they are structured like the eRec ones). Of course as you can do a lot of customer enhancements to HCMP&F you can replace the behavior nearly completely. One or two of my clients discussed this solution but as far as I know none is actually using it.
The simple truth is most customers seem to not use any integration at all. The first solution is easy to activate but only covers around 13 fields. Compared to a real full blow hiring action this is not even 10% of the fields which have to be entered. So the presetting this small number of fields is not a great help especially as you have to check every information anyways. Furthermore PA48 is not very nice and lacks functions to structure the incoming records which makes it difficult to handle in large distributed organizations.
The other two options require a lot of infrastructure for small functionality. What we discussed with a client was using the new hire integration to preset a full hiring form with eRec data and then send to the candidate as offline form to gather all missing information and use this for hiring. But there were to many issues on data privacy aspects when sending a form with social security data, bank account data, etc. via email. Furthermore they required actual signatures.
Kind regards
Roman -
Data transfer process: use values of filter in routine
Hi,
I create a filter in the data transfer process (RSA1). There are two infoobjects (ZABC, ZXYZ) in the filter.
I fill the first select-option (parameter) with the value u2018AAAAu2019. At the second line I create the filter routine:
form compute_/BIC/ZXYZ
tables l_t_range structure rssdlrange
changing p_subrc like sy-subrc.
In this routine I want to use the value u2018AAAAu2019 of ZABC:
SELECT SINGLE *
INTO lw_test
FROM /BIC/MZXYZ
WHERE
/BIC/ZBCA = (Select-option value from ZABC = u2018AAAAu2019)
Then I want to make a new entry in l_t_range from lw_test.
I thought that the Select-option will be in the table l_t_range. But there is only a record when it was also set by an ABAP-Routine but not the manual entries in RSA1.
How can I use the select-option from the filter?
Thanks in advance
Tobias Mattes
Edited by: Tobias Mattes on Jan 30, 2009 1:33 PM
Edited by: Tobias Mattes on Jan 30, 2009 1:34 PMCan you try to combine them into one routine? In other words, fill the range for both in the same routine - that way, you'll have all the values available to you.
For example:
l_t_range-iobjnm = 'ZABC'.
l_t_range-fieldname = 'ZABC'.
l_t_range-sign = 'I'.
l_t_range-option = 'BT'.
l_t_range-low = '2006001'.
l_t_range-high = '2006012'.
l_t_range-iobjnm = 'ZXYZ'.
l_t_range-fieldname = 'ZXYZ'.
l_t_range-sign = 'I'.
l_t_range-option = 'BT'.
l_t_range-low = '0101010'.
l_t_range-high = '0101099'. -
Error in Plan Data Transfer from CO
Hi,
I need to use Plan Data Transfer from CO (FM9C). But when I execute it, I have an error "CO Objects without FM Assgmt".
How can I setup the derivation between CO and FM objects?
All documentation that I've found are for SAP 4.6, but we are using SAP ECC 6.0...Hi,
Are you using former budgeting or BCS? If you use BCS, you should use FMCYCOPI_CO. In any case, to link CO objects to FM entities, use FMDERIVE strategy - it works for planning in the same way as it does for real postings.
Regards,
Eli -
Upgradation issue 4.6C to 4.7 for DP90-Data transfer module not allowed
Hi All.
We have a issue in upgradation project form 4.6C to 4.7.
Process we follow is Contract,Notification,Service order,Debit memo request.
While doing DP90 for service order we are facing a error as <b>Data transfer module is not allowed</b>
Afetr this system gives you only option to EXIT.
In the log display we get following message :
Data transfer module is not allowed
Message no. V1247
Diagnosis
A wrong data transfer module was entered in Customizing for copying control. When you enter a sales order with reference to a quotation, you cannot copy header data from an invoice, for example. The module number is 306.
System Response
Processing is terminated.
Procedure
Check the copying control for your transaction in Customizing or contact your system administrator.
Any idea how to deal with this
Regards,
Amrish PurohitHi Amrish,
There is a standard SAP program: SDTXT1AID. Start it, and the upper section you can find your incomplete parameters. Sign your relevant parameters (or all) and F8
(not test case).
I hope it will help you.
regards,
Zsuzsa -
VOFM - Shipment Data Transfer Routine
Hi Guru,
I have a requirement to create a routine in VOFM - Data Transfer - Shipment to copy the INCO1 to VTTS-INCO1 (item level). I have the checked the standard routine and it is all changing the header. Can anyone tell me the coding to use? Many many thanks.
Regards,
JanetHi.
The standard routine is as follows:
FORM DATEN_KOPIEREN_900
USING c_XVTTP TYPE v56i1_vttp_tab
c_XVTTS TYPE v56i1_vtts_tab
c_XVTSP TYPE v56i1_vtsp_tab
c_XTRLK type v56i1_vtrlk_tab
c_XTRLP type v56i1_vTRLP_tab
I_XVTTK STRUCTURE VTTKVB
VALUE(I_TVTK) LIKE TVTK
g_imp_data type v56I1_IMP_DATA
CHANGING C_XVTTK_tmp structure VTTKVB
g_exp_data type v56I1_exp_DATA.
VTTKVB is the header structure. Doesn't seems to have a item structure.
Regards,
Janet
Maybe you are looking for
-
not only safari is getting more difficult to use,its the flash problem for exemple,but also now it becomes strange when i change some settings (before when i open the safari window,it open with the top sites..now its impossibel to do this..i change t
-
Question re Flash Player installation in Explorer 9
I am using Internet Explorer 9. Most sites I go to or software I use tell me that I need to download the latest version of Flash Player, which I do and the installer tells me it was successfully installed. However the next time I go to the site it te
-
My original video source is 1280x688, 2600 kbps bit rate and I wanted to convert it to Ipad maximum 1024x768 resolution. I used WinX HD Video Converter which has options to use ipad output.. It took 24 minutes just to convert 5 mins of the 90 minutes
-
Streams between 9i Enterprise and 10g Standard
Hi, I'm currently trying to configure streaming between an oracle 9i Enterprise database and a 10g Standard Database. First of all, I would like to know if this is a configuration that can be done. Actually I'm facing some problems on the 9i side...
-
Disappearing Navigation buttons
Hi, I added some custom arrow buttons to my skin to replace the current previous and next buttons in the arrow bar. For some reason, they will not display. They're the same size as all of my other buttons, and they all show up without incident. When