DCNM - Nexus 1000v compatibility

Is DCNM v5.2(2a) compatible with Nexus 1000v v4.2(1)SV1(4a)?
We are getting an SNMP OID error when we try.
The compatibility matrix (http://www.cisco.com/en/US/partner/docs/switches/datacenter/sw/5_x/dcnm/matrix/matrix.html) is unclear.

Hello Grant.
4.2(1) is the NX-OS version for N1k.  The matrix indicates all SV1(4) versions are supported
SV14# sh version | inc system
  system:    version 4.2(1)SV1(4a)
Please let us know the exact SNMP OID error.  You may want to debug snmp errors on the N1k side when attempting to add the N1k.

Similar Messages

  • Nexus 1000v .jar file missing from Nexus1000v.5.2.1.SV3.1.1

    Hello ALL!
    I am trying to install and configure Nexus 1000v, for the first time and looking to configure the second stage of linking the Nexus 1000v switch to vCenter and from tutorials and white papers say to continue the install using a .jar file. However not seeing this file in the latest release in 1000v zip file.
    I can see this .jar file in the version 4 release and re-downloaded the v5 just incase it was corrupt and from a different machine; no .jar file.
    %windir%\Nexus1000v.5.2.1.SV3.1.1-pkg\Nexus1000v.5.2.1.SV3.1.1.zip\Nexus1000v.5.2.1.SV3.1.1\VSM\Install
    Cant find the white papers for v5, has anything changed?
    HELP!!
    JC

    Check this:
    http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/5_2_1_s_v_3_1_1/install_upgrade/workflow/nexus_1000v_r_5_2_1_s_v_3_1_1.html
    2-All files for this release can be found here:
    http://www.cisco.com/c/en/us/support/switches/nexus-1000v-switch/model.html
    HTH

  • Nexus 1000v, VMWare ESX and Microsoft SC VMM

    Hi,
    Im curious if anybody has worked up any solutions managing network infrastructure for VMWare ESX hosts/vms with the Nexus 1000v and Microsoft's System Center Virtual Machine Manager.
    There currently exists support for the 1000v and ESX and SCVMM using the Cisco 1000v software for MS Hyper-V and SCVMM.   There is no suck support for VMWare ESX.
    Im curious as to what others with VMWare, Nexus 1000v or equivalent and SCVMM have done to work around this issue.
    Trying to get some ideas.
    Thanks

    Aaron,
    The steps you have above are correct, you will need steps 1 - 4 to get it working correctly.  Normally people will create a separate VLAN for their NLB interfaces/subnet, to prevent uncessisary flooding of mcast frames within the network.
    To answer your questions
    1) I've seen multiple customer run this configuration
    2) The steps you have are correct
    3) You can't enable/disable IGMP snooping on UCS.  It's enabled by default and not a configurable option.  There's no need to change anything within UCS in regards to MS NLB with the procedure above.  FYI - the ability to disable/enable IGMP snooping on UCS is slated for an upcoming release 2.1.
    This is the correct method untill the time we have the option of configuring static multicast mac entries on
    the Nexus 1000v.  If this is a feature you'd like, please open a TAC case and request for bug CSCtb93725 to be linked to your SR. 
    This will give more "push" to our develpment team to prioritize this request.
    Hopefully some other customers can share their experience.
    Regards,
    Robert

  • SCVMM Kicks out Nexus 1000V Uplink NIC Any ideas?

    The SCVMM suddenly kicks out the Nexus 1000V Uplink NIC,
    thus preventing me from remediating the change.
    Also i get this error message
    Using Hyper V as virtualization platform

    Hello,
    You can use one Ethernet port-profile with a channel-group command (like 'channel-group auto mode on mac-pinning') and assign it to all the vmnic interfaces that need to carry the same set of VLANs
    The same port-profile can be used on other hosts too. The N1k would automatically bundle (port-channel) the interfaces that belong to the same ESX host (accomplished through the 'channel-group auto' command)
    If you need the interfaces to carry separate sets of VLANs, then you need a different port-profile.
    Port-profile is just a container for a common set of configuration that you can apply for multiple interfaces across multiple hosts.
    Thanks,
    Shankar

  • Firewall between Nexus 1000V VSM and vCenter

    Hi,
    Customer has multiple security zones in environment, and VMware vCenter is located in a Management Security Zone. VSMs in security zones have dedicated management interface facing Management Security Zone with firewall in between. What ports do we need to open for the communication between VSMs and vCenter? The Nexus 1000V troubleshooting guide only mentioned TCP/80 and TCP/443. Are these outbound from VSM to vCenter? Is there any requirements from vCenter to VSM? What's the best practice for VSM management interface configuration in multiple security zones environment? Thanks.

    Avi -
    You need the connection between vCenter and the VSM anytime you want to add or make any changes to the existing port-profiles.  This is how the port-profiles become available to the virtual machines that reside on your ESX hosts.
    One problem when the vCenter is down is what you pointed out - configuration changes cannot be pushed
    The VEM/VSM relationship is independent of the VSM/vCenter connection.  There are separate VLANs or L3 interfaces that are used to pass information and heartbeats between the VSM and its VEMs.
    Jen

  • Can a Nexus 1000v be configured to NOT do local switching in an ESX host?

    Before the big YES, use an external Nexus switch and use VN-Tag. The question is when there is a 3120 in a blade chassis that connects to the ESX hosts that have a 1000v installed on the ESX host. So, first hop outside the ESX host is not a Nexus box.
    Looking for if this is possible, if so how, and if not, where that might be documented. I have a client who's security policy prohibits switching (yes, even on the same VLAN) within a host (in this case blade server). Oh and there is an insistance to use 3120s inside the blade chassis.
    Has to be the strangest request I have had in a while.
    Any data would be GREATY appreciated!

    Thanks for the follow up.
    So by private VLANs, are you referring to "PVLAN":
    "PVLANs: PVLANs are a new feature available with the VMware vDS and the Cisco Nexus
    1000V Series. PVLANs provide a simple mechanism for isolating virtual machines in the
    same VLAN from each other. The VMware vDS implements PVLAN enforcement at the
    destination host. The Cisco Nexus 1000V Series supports a highly efficient enforcement
    mechanism that filters packets at the source rather than at the destination, helping ensure
    that no unwanted traffic traverses the physical network and so increasing the network
    bandwidth available to other virtual machines"

  • VN-Tag with Nexus 1000v and Blades

    Hi folks,
    A while ago there was a discussion on this forum regarding the use of Catalyst 3020/3120 blades switches in conjunction with VN-tag.  Specifically, you can't do VN-Tag with that Catalyst blade switch sitting inbetween the Nexus 1000V and the Nexus 5000.  I know there's a Blade switch for the IBM blade servers, but will there be a similar version for the HP C-class blades?  My guess is NO, since Cisco just kicked HP to the curb.  But if that's the case, what are my options?  Pass-through switches?  (ugh!)
    Previous thread:
    https://supportforums.cisco.com/message/469303#469303

    wondering the same...

  • Nexus 1000v - port-channel "refresh"

    Hi All,
    My question is, does anyone have any information on this 1000v command:
    Nexus-1000v(config)# port-channel internal device-id table refresh
    I am looking for a way for the port-channel interface to be automatically removed from the 1000v once the VEM has been deleted, currently the port-channel interface does not disappear when the VEM has been removed. This seems to be causing problems once the same VEM is re-added later on. Ports are getting sent into quarantine states and ending up in invalid states (eg. NoPortProfile state when there is actually a port-profile attached).
    Anyway, if anyone can explain the above command or tell me how to find out more, it would be great, I can't find it documented anywhere and the context-sensitive help in the NXOS is vague at best.

    Brendan,
    I don't have much information on that command, but I do know it wont remove any unused port channels.  They have to be manually deleted if they're no longer needed.
    The port Channel ID will remain even after a VEM is removed in case the assigned VEM comes back.  When a VEM is decommisioned permanently, I'll do a "no vem x" to also remove the Host entry for that VEM from the VSM.  This way the module slot # can be re-assigned to the next new VEM inserted.  After adding/removing VEMs just do a "show port-channel summary" to see any unused Port Channel IDs, and delete them.  It's a quick & painless task.
    I would hope this wouldn't be a common issue - how often are you deleting/removing VEMs?
    Regards,
    Robert

  • Cisco Nexus 1000v Virtual Switch for Hyper-V Availability

    Hi,
    Does anyone have any information on the availability of the Cisco Nexus 1000v virtual switch for Hyper-V. Is it available to download from Cisco yet? If not when will it be released? Are there any Beta programs etc?
    I can download the 1000v for VmWare but cannot find any downloads for the Hyper-V version.
    Microsoft Partner

    Any updates on the Cisco Nexus 1000v virtual switch for Hyper-V? Just checked on the Cisco site, however still only the download for VMware and no trace of any beta version. Also posted the same question at:
    http://blogs.technet.com/b/schadinio/archive/2012/06/09/windows-server-2012-hyper-v-extensible-switch-cisco-nexus-1000v.aspx
    "Hyper-V support isn't out yet. We are looking at a beta for Hyper-V starting at the end of February or the begining of March. "
    -Ian @ Cisco Community
    || MCITP: EA, VA, EMA, Lync SA, makes a killer sandwich. ||

  • Nexus 1000v and vcenter domain admin account

    I changed out domain admin account on our domain in which vcenter services runs as and now its using a different services account. I am wondering if I need to update anything on the nexus 1000v switch side between the 1000v and venter

    Hi Dan,
    You are on the right track. However you can perform some of these function "online".
    First you want to ensure that you are running at a minimum, Nexus 1000v SV1(4a) as ESXi 5.0 only began support on this release. With SV1(4a), it provides support for both ESXi 5.0 and ESX/i 4.1.
    Then you can follow the procedure documented here:
    Upgrading from VMware Release 4.0/4.1 to VMware Release 5.0.0
    This document walks you through upgrading your ESX infrastructure to VMware Release 5.0.0 when Cisco Nexus 1000V is installed. It is required to be completed in the following order:
    1. Upgrade the VSMs and VEMs to Release 4.2(1)SV1(4a).
    2. Upgrade the VMware vCenter Server to VMware Release 5.0.0.
    3. Upgrade the VMware Update Manager to VMware Release 5.0.0.
    4. Upgrade your ESX hosts to VMware Release 5.0.0 with a custom ESXi image that includes the VEM bits.
    Upgrading the ESX/ESXi hosts consists of the following procedures:
    –Upgrading the vCenter Server
    –Upgrading the vCenter Update Manager
    –Augmenting the Customized ISO
    –Upgrading the ESXi Hosts
    There is also a 3 part video highlighting the procedure to perfrom the last two steps above (customized ISO and upgrading ESXi hosts)
    Video: Upgrading the VEM to VMware ESXi Release 5.0.0
    Hope that helps you with your upgrade.
    Thanks,
    Michael

  • Nexus 1000V. problem when working with the console VMWare

    I have a problem when working with the console VMWare.
    Sometimes it is impossible to connect any of the hypervisor to the guest OS managed by them.
    I get the message: "Unable connect to the MKS: Host address lookup for server <name of the hypervisor> failed: No such host is known."
    This message always appears in conjunction with the reconfiguration of virtual switch: "Reconfigure vNetwork Distributed Switch .... Initiated by Cisco_Nexus_1000V_ ....."
    Upon completion of the reconfiguration, Communication console, with guest OS is restored, or on its own or after a reboot srv-vc.
    In this time, I do not see any message in Nexus 1000v log.
    What is this?
    Thanks in advance.

    Smells of a DNS issue.  Are you sure your ESX hosts are reachable from your client via DNS hostname?  Try pinging them from a command prompt/terminal.  You may have DNS server issues.
    As a temp fix, edit your [windowspath]/system32/etc/drivers/hosts file and manually add the ESX host name and IP, then re-test.
    Regards,
    Robert

  • Weird syslog format messages with Nexus 1000v

    I'm  trying out the Nexus 1000v, and have the VEM configured to write logs to my  syslog server. The thing is, the messages are in a weird format that my  log management tools cannot parse. Here is an example:
    <189>: 2012 Oct 21 15:22:40 UTC: %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by admin on unknown_session
    I found the documentation rather  amusing, where it states "The syslog client functionality is RFC-5424  compliant" - doesn't look like they've even read the RFC! This is closer  to the format of the older (but more often found in the wild,  RFC3164... though not compliant with that either :/
    Anyway,  I guess the main issue here is that the hostname of the 1000v is not  being added to the logs (it is set in my config). Any ideas how I can  fix this?
    Thanks!

    Hi,
         Do you have vCenter install on Win2012 Server? The installation would not continue until you have vCenter installed.
    Hardik

  • Vmware Tools for Nexus 1000v, VNMC and VSG

    Hi everyone, a customer is asking me about how to install the vmware tools in the virtual machines of N1Kv, VSG and VNMC.
    Someone knows the procedure, or if thats posiible or not.

    @Robert
    Wanted to know / understand what hardware version would be compatible for Nexus 1000V ? Is there any dependency for hardware version ?
    Regards,
    Amit Vyas

  • VWLC and Nexus-1000V

    Hi Experts!
    Does anybody try to install vWLC on ESX with Nexus-1000V as switch?
    All deployment guide are based on standard VMWare vSwitch and I can not find any information about questions:
    1. Is vWLC compatible with Nexus-1000V?
    2. What configuration should be done on Nexus-1000V to vWLC works properly?

    Hi Dave,
    You can access  below URL for nexus 1000v -4.0(4)SV1(3b) docs:
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_0_4_s_v_1_3_b/roadmap/guide/n1000v_roadmap.html
    And
    Nexus5000
    http://www.cisco.com/en/US/products/ps9670/tsd_products_support_series_home.html
    BR,
    John Meng

  • Nexus 1000V private-vlan issue

    Hello
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:Standardowy;
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin:0cm;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:10.0pt;
    font-family:"Times New Roman";
    mso-ansi-language:#0400;
    mso-fareast-language:#0400;
    mso-bidi-language:#0400;}
    I need to transmit both the private-vlans (as promiscous trunk) and regular vlans on the trunk port between the Nexus 1000V and the physical switch. Do you know how to properly configure the uplink port to accomplish that ?
    Thank you in advance
    Lucas

    Control vlan is a totally seperate VLAN then your System Console. The VLAN just needs to be available to the ESX host through the upstream physical switch and then make sure the VLAN is passed on the uplink port-profile that you assign the ESX host to.
    We only need an interface on the ESX host if you decide to use L3 control. In that instance you would create or use an existing VMK interface on the ESX host.

Maybe you are looking for

  • My wacom tablet won't work with CC photoshop any more.

    Over the past 3 days my tablet has become incredibly glitchy in CC. I'm on a Mac and I use an Intous 5 large tablet. I've tried everything recommended through the wacom site. I've reinstalled my drivers, updated my computer....ect. There where issues

  • Bluetooth Driver In Windows 8.1 is Not Working [Model Pavilion 15 E007TU]

    Sir Where is Th Bluetooth Driver for Windows 8.1 for the Laptop of Model Pavilion g6 pavilion 1318ax In Windows 8.1 Bluetooth Not Working

  • Premiere Pro 2.0 and Windows 7 - Direct Sound Input soundcard driver problem

    My XP machine crashed, I reinstalled Premiere Pro 2.0 with Windows 7, and I got the following error: 'The Currently installed soundcard driver does not support Direct Sound Input. Recording audio is not possible.' The soundcard drivers are updated. A

  • How to find an external HD

    Hello, my question is, when you eject a external HD from your Mac, how can you get it back if you need it again? Regards Alex

  • Facade and Session Facade

    All, Well this is the closet forum i could get to post my question so please excuse me if it is in wrong place. Can anyone mention the types of facade design pattern available ? Also what is the diff between Facade and Session Facade ? PS : My applic