Define Control Storage Loc error LT206

Hi guru´s
I went to config 'Table for storage location control' and tried entering a storage location but I'm getting an error message: LT206: Based on SType control, stor loc XXX is unsuitable for stor loc control.
path
Logistic Execution> Warehouse Management > Data Master> Define Control Storage Loc
What config is necessary for this case? Appreciate any help on this matter. I don´t understand why a can´t for this combination the error message appear.
that the type of storage is storage block has something to do?
Thank you in advance.
regards
Vasco

Hello Vasco,
you would use Stor. Location Control when you want to direct materials to different Storage location base on the movement types within a same Plant or warehouse. Check if you have maintained the right combination of the movement type and Sloc .
thanks,
Edited by: Ganesh Prabhakar C on Dec 14, 2010 1:04 PM

Similar Messages

  • Prod storage loc field in mrp2 view

    Hi, as i understand materials are stored in mm storage locations. from mm storage locations, materials will be issued to production orders. in this case why we need prod storage loc filed in mrp2 view of the material master? please advise in which scenario we need to use this field? is it necessary to define prod storage loc in discreate manufacturing? thank you all for your support.

    Dear ,
    Find the answer of your questions:
    1. why we need prod storage loc filed in mrp2 view of the material master?    It is nothing but a intrim stroge location between Store and Shop Floor specially nearby the Production Line from where componenet  are issued or back flashed  based on the SAP set up of Issu Storage Loaction Priority .
    Basically , if you want a SFG material to be issues to FG after in-house production of the SFG  and also want to keep some of the Bulk Item or common item which can be  issued immediatly upon reservation rather going to MMD store , then one way it will save your time .
    2.please advise in which scenario we need to use this field?   In case you have SFG/Bulk Item /Low value stock item which are utilised now and then in productiion line or in a group of work centre  and you want to material  can be picked up immediately as it near the operation line , then you have a facility to stock material called Issue or Production Storage Loaction .
    3.is it necessary to define prod storage loc in discreate manufacturing  It is not necessary .But REM  is is useful for Back Flashing iteem.For FG in house producted item , you can receive the material specifically as SFG/FG store to diffierentiate from others  .Some time , you can use the same to store the Sales Order stock based on MTO-Discrete Manufactruing for an cutomer order .
    Check my posting in this thread : Production Storage Location
    Hope this is helpful
    Regards
    JH

  • Error in picking material from storage loc.

    Hi Experts,
    I am creating a delivery w.r.t sales order. i am getting this following error.
    Material SRCBULK does not exist in plant GC01
    Message no. VL411
    I have checked the message and its corresponding upgrades. Its already there as i am having ECC 6.0 EHp1
    The material is already entended to storage loc and plant. Also there is sufficient stock.
    Please let me know if there is any config changes.

    Hi KC,
    Go though the link given below, It will help you out.
    Material F001TD does not exist in plant HDQF
    Regards,
    MT

  • Automatic Inspection Lot Creation for HUs (storage Loc.) in WHS

    Hi All,
    can someone guide me through customizing/with end result expected from client. How can I setup this configuration.
    The requirement is all Chem.Raw Materilas are subject to Quality inspection with HU managed storage Loc. with WMS.
    Good Receipt is posted Via Vl31n into Quality Stock. Subsequently a Transfer Order will be created & confirmed to transfer of materials from 902 interim storage type to destination storage type and bin. (due to lack of space in the Whse).
    Now expected is that when Usage decision made (Quality Managment) the stock type should change from Q to Unresticted within the same bin and same storage type and material should be made available to issue for orders.
    Also when GR is done 101 mvt. an inspection lot should generate automatically in Whse under the quant.
    Most appreciate your help.
    Regards
    Chandra

    Hi Chandra,
    Generally WM movement type '309' is assigned for posting change (Sap standard setting). This movement type is generally assigned against 321 IM movement type.
    Modify the settings for WM movement type '309' as below:
    Path: LE -> WM -> Activities -> Transfers -> Define Movement types
    - Automatic TO X (activate)
    - Activate 'To item can be confirmed immediately'
    - Activate 'propose confirmation'
    - Activate 'post to same bin'
    This should solve your problem.
    On your other question
    Generally the inspection lot is assosiated with the WM
    stock and Quant if the stock Quality stock is posted to bins directly.
    Please display the Quant using LS23 and let me know your findings.
    Regards
    Madhu

  • During GR against Process Order Storage loc. not appearing

    He Experts,
    I am trying to do goods receipt against process order for bulk material using MIGO.
    But under where tab in MIGO storage loc field is not appearing. For this material production storage location is maintained in MRP2 view & in material type customizing both quantity & value field is selected for a given plant.
    Can you please explain why this field is not appearing? Is there any other customizing behind this? During migo 101 movement type (GR for acct. assgt.) is appearing in moveent type field.
    Thanks in advance,
    Vijay.

    Hi,
    OK,You are trying to do GR for a materisl which is defined as Bulk Material (Can be done in BOM or Material master).
    You said , there is no stock appearing for this material in this Storage location.
    Check one thing,
    go to MMSC and find out whether the storage location is maintained for the material or not?
    if your Storage location is not appearing in the list, maintain it there.
    Create a new Process order/productrion order  and check
    Regards
    Ratan

  • Change storage loc in Sales order PO

    Hi to all,
                   Please help me in solving this problem, actually we have created a PO by referring a Sales Order PR with Acc cat-> 'X' and Item Cat-->'S', now the user wants to Change the Storage loc, but the storage loc is grayed out that is non editable, i want to know whether this is a standard functionally of thirdparty PO with item category 'S'  or else any configurational changes need to be done. for your information the PO is manual PO, I searched all over the scn i could not able to find it plz if this question is already posted plz let me know the link of the question .
    Thanks in advance

    Yes. It is a standard behavior. You can't use the storage location field for item category S.
    Its because, the material will direct goes to delivery address location instead of storage location.
    Normally, system will not accept storage location for the PO line item which has the item category S.
    If you want to keep the storage location for your reporting purpose, then you can use the storage location field as per your requirement.
    Go to path OLME-Purchase Order-Define Screen Layout at Document Level. Double click on PT5F field selection group.
    then double click on Basic Data, Item.
    Then make the storage location as per your requirement (Optional or required).
    Then you can able to enter or change the storage location in ME21N or ME22N.
    But remember, it will not effect at the time of MIGO.

  • Relation between storage loc and workcenter/resource

    Dear Gurus
    My client wants that whatever materials (fert) coming out from a particular workcenter/resource should be posted to a particular storage location.And that the system should propose the storage location while posting of goods.Can a storage location be assigned for any workcenter/resource.
    Regards
    Sandip Sarkar

    Hi,
    2 suggestions:
    1. I presume you have created different routings / group counters within the same routing each specifying the different work center from which you can assemble / manufacture the final product.
    Now create different production versions, by specifying the routing & bom details in the PV. Also in the PV, in the section Other Data, you will find a field called Receive Location, here specify the storage loc. relevant for each work center.
    Now when you create the order, read the production version which is relevant i.e. depending on the work center, then once the order is completed system will post the stock to the SLoc which you have pre-defined.
    2. Use BADi - WORKORDER_UPDATE, method - AT_SAVE or use User exits PPCO0006 or PPCO0007. Create a Z table with Work center and Sloc & this enhancement you can refer to the work center and assign the relevant SLoc, discuss with your abaper.
    Regards,
    Vivek

  • Stoc under Storage Loc./Batch Stock, needs to bring under Valuated Stock

    Dear All,
    I have one question:
    We have done Sales Return for Qty: 200 for Material: XYZ.
    Now, in MB5B, under Valuated Stock, for the Material: XYZ, Qty is 346; whereas
    under Storage Loc./Batch Stock, Qty is 556.
    When, I refeered to MB52, its showing Qty as:
    unrestricted: 346
    Return: 200
    How come, i bring this Qty: 200 under unrestricted/ Valuated Stock?
    Please breif me the procedure.
    Best Regards,
    Amit

    Dear KI,
    As Suggested by You,
    I went to Transaction: MB5B and choosen Movement type: 459 - TP Ret. to own blckd
    Also, ticked Box: Storage Loc./ Batch Stock, and Executed (F8).
    I got following error:
    If there are restrictions acc. to movement type, results may be incorrect
    Message no. M7391
    What do i do next?
    Best Regards,
    Amit
    Note: I am SD-Consultant and my MM-Counterpart is un-available. So, user asked the same to me. It would be great help, if you tell me the steps (with Details like T. Codes and Movement Types etc..)

  • Sale Order change BAPI - Storage loc not updated

    Hi Everybody,
    Iam using "BAPI_SALESORDER_CHANGE", to change the sale order items.
    First iam calling above bapi with switch B, for new pricing & then second time for material change.
    When i change any material number, it is getting updated correctly.
    But the storage location, even though iam passing in the bapi it is not updated, & is blank - updation flag is also passed.
    When i execute sale order change again it is updated - ie, for any material change for first bapi call, storage loc is not updated - for 2nd bapi call storage loc is updation - for same input in both the cases.
    Is there any way to update the storage loc is first call of sales order change bapi.
    Below is the parameters iam passing in bapi :
    CALL FUNCTION 'BAPI_SALESORDER_CHANGE'
        EXPORTING
          SALESDOCUMENT      = LS_SALESDOCUMENT
          ORDER_HEADER_IN    = LT_HEADER_IN
          ORDER_HEADER_INX   = LT_HEADER_X
        TABLES
          RETURN                            = LT_RETURN
          ORDER_ITEM_IN               = LT_ITEMS
          ORDER_ITEM_INX             = LT_ITEM_X
          ORDER_CFGS_REF          = LT_CFGS_REF
          ORDER_CFGS_INST         =  LT_PARTS
          ORDER_CFGS_VALUE     = LT_VALUES
          ORDER_CFGS_BLOB        = LT_CUBLOB
          ORDER_CFGS_VK            = LT_CUVK
          ORDER_CFGS_REFINST   = LT_CUREF
          SCHEDULE_LINES            = LT_SCHEDULE_L
          SCHEDULE_LINESX         = LT_SCHEDULE_X
          ORDER_TEXT                   = LT_TEXT
          CONDITIONS_IN                = LT_CONDITION_L
          CONDITIONS_INX              = LT_CONDITION_X.
    Any help is appreciated.
    Regards,
    Nagarajan.J

    Hi,
    Storage location is updated only when same sale order bapi is called another time with required details.
    rgs,
    Nagarajan J

  • Error -2500 Internal storage VI error

    Hello,
    I am trying to continuously stream data from seven channels from my NI USB-6211 DAQ card. At the same time I am generating a continuous sine wave and write it to one of my analogue outputs on the same card.
    I’d like to stream the data generated and measured continuously and simultaneously to a file. I have chosen TDMS as this seems to be most appropriate for the application.
    The problem I am having is that available samples per channel gives me back 0 when I am not in highlight execution. I tried to overcome this by setting the samples to read input at the DAQmx Read VI to -1 and have a wait function to not read too often but this didn’t help. Furthermore, I installed TDMS 2.0 without any success. The error I am getting is -2500 and it says "Internal storage VI error". Does anyone have an idea what I am doing wrong? 
    Also, it would help quite a lot if I could have a time axis for the analogue output and one for the analogue input group so I can look at the time delays introduced by my circuit. Does anybody know how to do this, so I have a time stamp for each sample like in the express VI? Or any other way to find the relationship between the data of the two groups when sampling is carried out at different rates?
    Thank you very much for your help,
    Sophie
    Attachments:
    sync data.JPG ‏135 KB

    Ok, so I wasn't sure what you ment exactly. I have tried to do the same with just the TDMS VIs. It seems to be working fine. I don't get any errors and the TDMS file seems complete too. 
    I had the feeling DAQmx Read (just the one in the upper loop) gives the error as it doesn't seem to detect any samples to read. Which would also explain why I don't get the error in highlight execution, because then there are samples to read.  This is why I added the wait VI in the loop and made it 3s hoping this will allow some samples to be collected in the buffer but there just don't seem to be any samples.
    I have attached an image of the TDMS VI I just tried out, I can add more things if you have any ideas... 
    Attachments:
    tdms.JPG ‏58 KB

  • Internal Storage VI error

    I am acquiring multiple channels at 5KHz (continuous) and down-sampling some of them to then store using the storage VIs. There is also some online signal processing (i.e. FFT) and visualization. On the block diagram I open a file using the event structure on a button press and then my acquisition loop includes the Write Data subVI. But it seems the overall speed of the VI slows down considerably when recording starts and even seems to fall behind acquisition speed (graphs show changes in waveform later than when they actualy happened). I then get an error that shows up periodicaly at the storage VI that says "Error -2500: Internal storage VI error" and thats all the info I get. When that error happens I think I also loose some data evident from warnings I get on my filters that notify me the data has lost continuity. Something is wrong but I can't figure out what. HELP anyone? Thanks.

    No, I am not opening and closing inside the loop. I open the file outside the loop via en event using "Open Data Storage" VI, and then I am using the "Write Data" VI (TDM format, writes 2 files, one XML and one binary if I understand correctly the format). The Write Data is used inside an acquisition loop that collects 7 (or 9) channels at 5KHz (500 samples per loop, so 0.1sec of data per loop) but then resamples two of these channels down to 400Hz and 50Hz respectively, the rest stay at 5KHz. So yes, I am streaming the data and I assume it writes it in blocks on each loop (not byte at a time).
    Does this help clarify?

  • How to make screen field enable when table control gives an error

    Hi,
        I had a scneario like when table control data wrong then one parameter of the screen should be enabled for the input, i knew that screen-name will not work since it will have always table control fields only when table control gives an error.
    How to make the other parameter enable when table control throws an error.
    Regards,
    Jaya

    Hi Gobi,
         Thanks for your response, but issue is - how to make other screen fields enable when there was an error in the table control data.
    For table control - lets say we will use the code as i mentioned above.i am sure that we cant write the code for field enable in between loop & endloop.
    as you said if we right outside the loop-endloop, the module wont be triggered when table control throws an error, because that statement was not there in the loop-endloop.
    please let me know if you need any more information on the issue. I hope there is alternative for this in SAP.
    Thanks
    Jaya

  • Control Framework: Fatal error - GUI cannot be reached

    Hello All,
       Iam using BDC for creating a ZCR order throught VA01 - Credit Memo request. When executed in the foreground, it works fine.But when ran in background gives an error message - Control Framework: Fatal error - GUI cannot be reached  and gives a short Dump for 'RAISE_EXCEPTION'.
    Please suggest.

    Normally, BDC should run the same way whether it is in background of Foreground.
    No, BDC does not run  the same way in background and foreground
    To understand BDC in background : different behavior or termination read those OSS notes :
    - [Note 33319 - Batch input: Backgr. runs diff. than in the dialog|https://service.sap.com/sap/support/notes/33319]
    - [Note 311440 - Batch input and controls|https://service.sap.com/sap/support/notes/311440]
    Also this note of interest :
    - [Note 554139 - FAQ 2: Batch input|https://service.sap.com/sap/support/notes/554139]
    Regards,
    Raymond

  • What is the use of Storage loc.ref.in LE-WM Interface to Inventory Managemt

    Hi Guys
    What is the use of below fields
    Special movement indicator for warehouse management and Storage loc. ref.
    In the WM configaration LE-WM Interface to Inventory Management
    How we can do the below scenario with this configaration
    I have 3 scenarios all scenarios have MIGO and placing stock to WM
    2 scenarios requres Immediate TO creation after MIGO 101 mvt type
    But last scenario does not want Immediate TO ,it is having another Z transaction to create TO
    But problem is for the last scenario also creating Immdiate TO after MIGI 101
    How to avoid this Immdiate TO for this scenario
    And How to allow it for first 2 scenarios
    How we can to with that configaration

    Hello ,
    It is not possible directly in customising as all three cases are using the same Mvt Type.
    Alternate Solution :
    You may try an by creating a new Mvt Type 901 i.e making a copy of 101.
    Thereafter try to link a new Ref Mvt Type to the same .You should use this case for the third scenario.
    This may resolve your problem.
    Regards
    Ramesh Ch

  • "Not Enough Storage Space" error - Acrobat 9 Pro

    Hey gang,
    I get a "not enough storage space" error message when trying to install Acrobat 9 Pro.  I've got administrative rights and I'm trying to install from my local drive.  Any ideas?  Thanks!  I've attached a screen shot of the error message.
    My system particulars:
    Windows 7 Pro (64-bit)
    Acrobat 9 Professional
    8 GB RAM
    132 GB free on hard drive
    Thanks again,
    -terry-

    I cleaned the Temp directory and rebooted, making sure to kill the processes in the Startup folder.  It went smooth like a gravy sandwich.  Thanks for the help!
    -terry-

Maybe you are looking for

  • Pls help me to modify the query for performance improvement

    Hi, I have the below initialization DECLARE @Active bit =1 ; Declare @id int SELECT @Active=CASE WHEN id=@id and [Rank] ='Good' then 0 else 1 END  FROM dbo.Students I have to change this query in such a way that the conditions id=@id and [Rank] ='Goo

  • I havent updated my operating system on my iphone 3gs in over a year will i lose all my numbers by doing it?

    I didn't have any issues till I had to get the screen replaced yesterday because I finally dropped it one too many times.  By doing so some of  my apps were deleted, ie: Facebook and others. I tried to redownload them but my phone has not been synced

  • SAP Management Console reporting connection failed

    <p><b>When using Internet Explorer to access SAP Mangement Console @ http://spjcen00:50013 , one instance reporting connection failed.  I am loading a landscape export file containing 10 distincts SIDs.  Only this one is failing and started about 10

  • BAPI_SERVNOT_MODIFY_DATA

    Hi all, I need to use <b>BAPI_SERVNOT_MODIFY_DATA</b> to modify a field for the service notification. Can anyone show me an example of the code? Service Notification Number = 2510034692 I want to add "<i>Testing</i>" into Small Text field After which

  • Correct font not used

    The drop-down menu at the top of the noted site does not display correctly in Firefox 8.01. I does display correctly in IE, Chrome, and Opera. It looks to me like Firefox does not use the correct font for the display, which causes the list to wrap ra